5-BTS3900 V100R010C10SPC255 (eNodeB, FDD) Upgrade Guide (LMT-based)
5-BTS3900 V100R010C10SPC255 (eNodeB, FDD) Upgrade Guide (LMT-based)
Issue
01
Date
2016-01-30
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website:
http://www.huawei.com
Email:
support@huawei.com
Issue 01 (2016-01-30)
Preface
Preface
Purpose
This document describes how to upgrade a base station to V100R010C10SPC255 and how to
roll back the upgrade using the LMT. It also provides FAQs and troubleshooting methods.
Intended Audience
This document is intended for upgrade personnel. Upgrade personnel must:
Have device maintenance experience and be familiar with device operation and
maintenance.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Conventions
Symbol
Description
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to
personal injury.
Calls attention to important information, best practices
and tips.
Issue 01 (2016-01-30)
ii
Symbol
Preface
Description
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.
Change History
Issue
Date
Description
01
2016-01-30
Owners
Prepared
by
Qing Cui
Date
2016-01-26
Reviewed
by
Bao Jian
Date
2016-01-27
Tested by
Mao Dahua
Date
2016-01-27
Approved
by
Zhang Benkuang
Date
2016-01-30
Issue 01 (2016-01-30)
iii
Contents
Contents
Preface........................................................................................... ii
1 Before You Start...........................................................................1
1.1 Getting Started................................................................................................................................................................1
1.2 Version Requirements.....................................................................................................................................................1
1.3 Impact on the System During the Upgrade....................................................................................................................2
1.4 Mode-by-Mode Upgrade of a Multimode Base Station.................................................................................................2
1.4.1 Impact on Peer Services..............................................................................................................................................2
1.4.2 Loading Control Rights...............................................................................................................................................2
1.5 Precautions for the Upgrade...........................................................................................................................................3
Issue 01 (2016-01-30)
iv
Contents
7 FAQs........................................................................................... 26
7.1 What Do I Do If the Number of Failed Boards Is Not 0?............................................................................................26
7.2 How Do I Handle the LMT Malfunction after an Upgrade?........................................................................................26
7.3 How Do I Determine the BootROM Version?..............................................................................................................28
7.4 How Do I Select and Use Upgrade Software Packages?.............................................................................................28
Issue 01 (2016-01-30)
This document describes how to use the LMT to upgrade BTS software to BTS3900
V100R010C10SPC255.
Upgrade Note
The source version of an eNodeB must be listed inTable 1.1 even if a hot patch is installed on this
eNodeB. To query the source version of the eNodeB, run the LST VER command in the MML window
of the LMT.
Issue 01 (2016-01-30)
The target version of the eNodeB has the loading control right over co-module RF
modules. For details, see 1.4.2Loading Control Rights.
The multimode base station supports inter-subrack connection. Users can run the DSP
BRD command to query whether the eNodeB is configured with a UCIU board.
Co-transmission is applied on the base station and the eNodeB provides a cotransmission port.
For details about which mode has loading control rights, see Appendix 1 Version Mapping
Information. You can obtain this appendix from the multimode base station release notes in
the document package delivered with the software version of the multimode base station.
For detailed operations, see 4.2(Optional) Setting Loading Control Rights of a Multimode
Base Station.
Issue 01 (2016-01-30)
This document instructs operation personnel to upgrade co-MPT base stations in batches
on the LMT.
To guarantee that the base station can be correctly upgraded using the LMT, the web
browser version of the PC on which the LMT is installed (LMT PC for short) must be:
Microsoft Internet Explorer 8 or 9
FireFox 3.0 or later
If any of the following alarms is generated in the base station to be upgraded, clear the
alarm before the upgrade. Otherwise, the upgrade will fail.
ALM-26235 RF Unit Maintenance Link Failure
ALM-25901 Remote Maintenance Link Failure
ALM-26270 Inter-System Communication Failure
ALM-26272 Inter-System RF Unit Parameter Settings Conflict
ALM-26274 Inter-System Board Object Configuration Conflict
ALM-26277 Inter-System Control Rights Conflict
ALM-26279 Inter-System Board Installation and Configuration Mismatch
Check whether the LMT IP address of the base station to be upgraded has been changed
before the upgrade. If it has, obtain the new IP address.
Do not run configuration commands for the base station that is being upgraded, including
the ADD, MOD, RMV, and SET commands. If you must do so, log in to the LMT and
run the DSP SOFTSTATUS command to check the software status of the base station.
Operations can be performed only when the software status is Idle.
If a license file needs to be reloaded for the target version, obtain the license file of the
current version before the upgrade. Ensure that the original license file can be reloaded if
the eNodeB is rolled back. Determine whether you need to apply for an eNodeB license
and reload it by referring to section 3.9.1Checking Whether You Need to Apply for an
eNodeB License. For details about how to back up a license file, see section 3.10Back
Up the License File of an eNodeB.
This document uses the figures of the upgrade from BTS3900 V100R008C00SPC260 to
BTS3900 V100R010C10SPC255 as an example. During the actual upgrade process,
replace BTS3900 V100R010C10SPCXXX with BTS3900 V100R010C10SPC255.
Do not perform the following operations during the upgrade process, including software
downloading, activation, and process between the downloading and activation:
Issue 01 (2016-01-30)
Reset the base station or a board in the base station by running commands or
pressing the board reset button
Issue 01 (2016-01-30)
Task
Expected Result
10
11
12
Issue 01 (2016-01-30)
No
.
Task
Expected Result
upgraded, has been obtained.
Method 1:
Click the hyperlink BTS3900 and log in to http://support.huawei.com using a Huawei
engineer's account to download the reference documents and upgrade software package.
If the language of the displayed window is not in the target language, select the target language in the
upper plane.
Method 2:
Log in to http://support.huawei.com using a Huawei engineer's account and then search
for BTS3900 on the Software tab page. Click the association result. In the displayed web
page, select the target version.
Step 2 On the Software tab page, find and click the target upgrade software package to download it.
If the source versions are BTS3900 V100R008C00SPC150 or later, you are advised to
download BTS3900 V100R010C10SPC255_ALL(Software)support from SRAN8.0 and
later Versions.7z to save the download time.
Select an appropriate upgrade software package based on the source version and mode of the base
station. For details, see 7.4How Do I Select and Use Upgrade Software Packages?
Issue 01 (2016-01-30)
Tool
Quanti
ty
Function
PC
----End
is displayed on the right of the taskbar, the FTP server has started successfully.
Huawei Proprietary and Confidential
Copyright Huawei
Technologies Co., Ltd.
You must modify the password as prompted upon first startup of the FTP software. The default initial
password is hwbs@com and must be changed based on the planning.
If
is displayed on the right of the taskbar, the FTP server has not started. If this occurs, check
whether another FTP software is running on the PC. If so, exit the FTP software. Then, right-click
and choose Start FTP server from the shortcut menu to start the FTP server.
Step 4 Right-click
Step 5 In the FTP server configuration dialog box displayed in Figure 5.1, set the following
parameters:
Set User name to admin (default value). Users can change it as required.
Set Working directory to the root directory of the FTP server, which is D:\ftp.
If the source version is V100R008C00SPCXXX and the software package is saved at D:\ftp, you
must set Working directory to D:\ftp.
When changing Working directory, enter the password again in the displayed FTP password
authentication dialog box to confirm the change.
----End
If the value of failure in the Results bar is 0, the self-test is successful, as shown in
Figure 1.1.
If the value of failure in the Results bar is not 0, identify and resolve the problem. If the
problem persists, contact Huawei technical support.
Issue 01 (2016-01-30)
For details about how to set FTP User Name, FTP Password, and Server Path, see Step 5.
----End
Issue 01 (2016-01-30)
10
Then...
Table 1.2 Suggestions about whether to apply a new license for an eNodeB
If...
Then...
Set User Name and User Password to the user name and password, respectively.
Issue 01 (2016-01-30)
11
----End
Issue 01 (2016-01-30)
12
For a multimode base station, loading control rights must be set. The setting is not required
for a single-mode base station.
To set the loading control rights, perform the following steps:
Step 1 In the main window of the LMT, click MML.
The MML window is displayed.
Step 2 Run the DSP LOADCTRL command in the MML window. Query and record the settings of
the loading control rights as well as the software version of the peer mode.
Step 3 Run the SET LOADCTRL command with the parameter settings shown inFigure 3.1 in the
MML window.
Issue 01 (2016-01-30)
13
Figure 3.1 Setting the loading control rights for the eNodeB
Setting
Load Control
Flag
If the peer mode has been upgraded to the corresponding target version,
query the mode that has the loading control rights in Appendix 1 Version
Mapping Information, which can be obtained from the directoryRelease
Notes\ Multimode Base Station Release Notes\Release Notes
(Word_Excel) in the document package delivered with the software version
of the multimode base station.
If the loading control rights belong to the LTE mode, select YES(Set
Control Flag).
If the loading control rights belong to the GSM, UMTS, or Wimax mode, select
NO(Cancel Control Flag).
Effect
Immediately
Flag
Self Software
Version
Peer Software
Version
Control Mode
Issue 01 (2016-01-30)
NOTE
To query the running version of the peer mode, run the DSP LOADCTRL
command.
14
Parameter
Setting
individually in two separate sessions. The setting sequence can be
reversed.
The parameter value TL indicates that the base station is a TDSCDMA+LTE TDD base station, and therefore TL does not apply
to LTE FDD base stations.
----End
If the upgrade risk check results show that BootROM needs to be upgraded, download the
software package of BTS3900 V100R010C10SPC255 and upgrade the BootROM in the
software package.
During the BootROM upgrade, an unexpected board reset may damage the BootROM or
cause a board restart failure. If this occurs, return the damaged board to Huawei for
repairs.
2.
Enter the user name of the FTP server in the FTPServer User text box.
3.
Enter the password of the FTP server in the Password text box.
The user name and password must be the same as those set in Step 5.
Issue 01 (2016-01-30)
15
Step 6 On the Software Management tab page, click the Upgrade BootROM tab, and set the
upgrade options shown in Figure 6.1 as follows:
1.
2.
In the File path text box, enter the save path of the BootROM package, such as D:\ftp.
Step 7 Click Execute. A dialog box is displayed, indicating the status and progress of the BootROM
download and activation.
After the activation progress reaches 100%, the boards that are activated and those that failed to be
activated are displayed.
If a board fails to be activated, repeat Step 1 through Step 6 to upgrade the BootROM again.
----End
Issue 01 (2016-01-30)
16
2.
Enter the user name of the FTP server in the FTPServer User text box.
3.
Enter the password of the FTP server in the Password text box.
The FTPServer User and Password must be the same as those specified in Step 5.
Step 6 On the Upgrade Software tab page shown in Figure 6.1, set download-associated parameters
as follows:
(Optional) If you must upgrade the configuration files, select Download Configuration
File and Activate Configuration File.
When Delay Download by Flag is set to YES(Delay Download), the upgrade duration shortens by
approximately 10 minutes. As a result, only the basic functions of the LMT are available after the
upgrade. However, LMT files will be automatically supplemented on the NodeB four hours after the
upgrade. If all LMT functions are required in an emergency, run the SPL SOFTWARE command
immediately after the upgrade is complete.
Issue 01 (2016-01-30)
17
Step 7 On the Upgrade Software tab page, select Activate Version Software and click Query to
query the current software version of the base station. The query result is displayed on the
Message tab page, as shown in Figure 7.1.
Figure 7.1 Software version query
Step 8 On the Upgrade Software tab page shown in 4.3.2Upgrading the Base Station Software, set
Software version to V100R010C10SPC255 and click Execute to start the upgrade.
The upgrade progress is displayed on the Message tab page. When the upgrade progress reaches 100%
and the upgrade is successful, the base station is automatically reset and disconnected from the LMT PC.
Perform corresponding operations if the following issues occur:
Issue 01 (2016-01-30)
18
If Failed Boards are not 0, see 7.1What Do I Do If the Number of Failed Boards Is Not 0?
If Running Status is Fail and if a message is displayed indicating that the version after the upgrade
is not the target version, the upgrade has failed and the base station has been automatically rolled
back to the source version. When this happens, ensure that the software version is correct and
perform the upgrade again
After the software is successfully activated and the base station is reset, the base station
automatically rolls back to the source version if the base station fails to connect to the U2000
or LMT within 30 minutes.
Step 9 (Optional) On the LMT, click MML and then run the SPL SOFTWARE command in the
MML window to supplement the software, with the parameters setting as follows:
After the supplement is successful, the LMT exits automatically.
1.
Set FTP Server IP to the IP address of the PC used for logging in to the LMT.
2.
Set User Name and Password to the user name and password set in Step 5 in
3.5Configuring the FTP Server respectively.
3.
4.
5.
Issue 01 (2016-01-30)
19
----End
The Force Flag parameter indicates whether to forcibly install the license. If this parameter is set to
YES(Yes), any minor error occurring during the license installation will be ignored and the license file is
forcibly installed. If this parameter is set to NO(No), any minor error occurring during the license
installation will be displayed and the license file is not installed.
Issue 01 (2016-01-30)
20
After an upgrade, follow the instructions in this chapter to verify the upgrade.
If the base station cannot start up after the upgrade, it will be automatically rolled back to the
source version. The rollback takes about 15 minutes, during which base station services and
maintenance are interrupted. Therefore, wait 15 minutes before you log in to the base station
using the LMT. After you successfully log in to the base station, perform a self-test on the
LMT to check whether the rollback is successful. For details about how to perform a self-test,
see 3.6Checking the Status of the Base Station.
Task
Expected Result
5.5Checking Alarms
5.6Verifying Services
Issue 01 (2016-01-30)
21
The base station does not generate major alarms within 10 minutes.
The alarms that are expected to be cleared in the target version are cleared.
The alarms that are not expected to be cleared in the target version are not cleared.
Perform dialing tests and verify that anomalies such as call drops, one-way audio, and
noise do not occur.
Perform data service tests and verify that data services are processed properly.
Issue 01 (2016-01-30)
22
For a multimode base station, if multiple modes that have been upgraded to the target versions
need to be rolled back, it is recommended that all the target versions be rolled back to the
source versions.
If configuration parameters are modified after an upgrade, this command will invalidate the
modified values of the parameters. Before running this command, assess impacts of the
modified configurations and determine whether the impacts are acceptable.
Issue 01 (2016-01-30)
23
Figure 2.1 Setting the loading control rights for the eNodeB
Setting
Load Control
Flag
If the peer mode has not been upgraded to the required version of MBTS
BTS3900V100R010, determine the settings of the loading control rights based
on section 4.2 Checking the Software Status of the eNodeB."
If the loading control rights belong to the LTE mode, select YES(Set Control
Flag).
If the loading control rights belong to the GSM, UMTS, or WiMAX mode,
select NO(Cancel Control Flag).
Effect
Immediately
Flag
Self Software
Version
Peer Software
Version
Control Mode
The parameter value TL indicates that the base station is a TDSCDMA+LTE TDD base station, and therefore TL does not apply to
Issue 01 (2016-01-30)
NOTE
To query the running version of the peer mode, run the DSP LOADCTRL
command.
24
Parameter
Setting
LTE FDD base stations.
----End
During the rollback, do not reset the base station or any board, power off the base station, or
remove any board. Doing so will cause the rollback to fail.
Run the RBK SOFTWARE commandto perform a version rollback without the need of
parameter settings. Then, the configuration data is restored to the pre-upgrade status.
During the rollback, the MML command information pane shows the rollback progress. When
the progress reaches 100% and the execution result is Operation Succeeded, the system is
reset and the rollback is complete.
If the execution result shows that Failed Boards is not 0, refer to section 7.3 "How to Back Up
the License File of an eNodeB?" to resolve the problem.
If a license file is loaded during the upgrade, determine whether the license file needs to be
reloaded based 3.9.1.1.1Step 1Table 1.1 after the version rollback from
V100R010C10SPC255.
Issue 01 (2016-01-30)
After the software version is rolled back to a source version earlier than SRAN10.1, the names of
new alarms and events in SRAN10.1 will be displayed as Undefined on the LMT.
After an eNodeB in V100R010C00SPC050 is rolled back to the source version that is earlier than
V100R010 series, there is a low possibility that ALM-26200 Board Hardware Fault is reported on
the LBBPc. If the alarm cannot be cleared within 10 minutes, run the RST BRD command to reset
the LBBPc to resume services.
25
7 FAQs
FAQs
Troubleshooting
Method
RU is not online
If the fault persists or Failed Info is none of the above, contact Huawei technical support.
26
7 FAQs
first time after the upgrade, you need to clear the cache, cookies, and java applets in the
browser.
Table 1.1 To clear the cache and cookies in the browser, perform the steps shown in the following
table
Browser Type
Handling Procedure
Firefox
1. Open the Firefox browser, and choose Tools > Clear Private
Data from the menu bar.
2. In the displayed Clear Private Data dialog box, select the
Cache, Cookies, and Offline Website Data check boxes, and
click Clear Private Data Now.
Before you clear the Java Applet, exit the LMT. Otherwise, some loaded data will be lost and
unexpected errors will occur.
To clear the Java Applet, perform the following steps:
Step 1 Choose Start > Control Panel. The Control Panel is displayed.
Step 2 Double-click Java in the displayed window. The JAVA Control Panel is displayed.
Step 3 On the General tab page, click Settings. The Temporary Files Settings dialog box is
displayed.
Step 4 Click Delete Files. In the displayed Delete Temporary Files dialog box, select the
Applications and Applets and Trace and Log Files check boxes, and click OK.
Step 5 In Java Control Panel, click OK.
Step 6 The operations take effect after the browser restarts.
----End
Issue 01 (2016-01-30)
27
7 FAQs
Versions with the format XX.XXX.XX.XXX are released later than those with the
format VXXXRXXXCXXBXXX.
Eliminate the non-digital characters contained in the version number in the same format,
and you get a number. The larger the number, the later the BootROM version is. For
example:
In Version A (01.012.00.200) and Version B (01.013.01.001), the number of Version A is
101200200 and the number of Version B is 101301001. Because 101301001 is larger
than 101200200, Version B was released later than Version A.
Package
Type
Software
Version
Package Name
Single-mode
package
eNodeB
package
BTS3900
V100R010C10SPC2
55
BTS3900
V100R010C10SPC255_eNodeB(Sof
tware).7z
Issue 01 (2016-01-30)
An SRAN package supports upgrades of base stations of different modes. If you need to
upgrade a multimode base station or a site with several single-mode base stations,
download the SRAN package.
If the source versions are BTS3900 V100R008C00SPC150 or later, you are advised
to download the simplified SRAN package to save the download time.
28
Issue 01 (2016-01-30)
7 FAQs
29
Site Name
Verification Time
Verification Result
Passed Failed
Cell Name
Cell ID
Task
Result
CS Services
Good Acceptable
Unacceptable
PS Services
Description
Remarks
Verified By (Signature)
Issue 01 (2016-01-30)
30
C
Co-MPT
E
eNodeB
E-UTRAN NodeB
F
FTP
G
GBTS
I
ID
ID
IP
Internet Protocol
L
LMT
M
MBTS
Issue 01 (2016-01-30)
31
MML
Man-machine Language
S
SIM
U
UMPT
Issue 01 (2016-01-30)
32