Professional Documents
Culture Documents
Unit Capacity: 2 1 0 MW
Unit Capacity: 2 1 0 MW
Unit Capacity: 2 1 0 MW
U N I TN o .- 4
TPS:NASIKTHERMALPOWERSTATION
1 . H OCo d e :
StationCode3112013-14
Time10 32 Hr s
UnitCapacity:
2 1 0M W
DateNo.of daysfromlast
03t11t2013
synchr.:-0
GoalCyclesin service:
Oil Support:
1 5M W
4A
AB,CD
5 . A) Observations:
Actionlworkdone:5 . B) Remedial
> lV (Left)closelimitswitchcablefoundburntandshort.
) Fourcorecable& limitswitchreplaced
andconnection
normalized.
6. RootCauseAnalysis:H P C V1 & 2 .
pipeflangejointleakage.
leakagefromHPTTransfer
7 . Preventiveaction suggested(ShortTerm):-
lP turbineareain shortshutdown.
8 . Preventiveaction suggested(Long Term):-
r, l l
Boilerlightedup
Time: 10.35Hrs
Date:- CI311112013
T i m e : - 1 1 . 3 5H r s
Date:- 0311112013
Remark:- Totaloutage
time- 1.03hrs & Genloss- 0.221 MUs
NTPS:MSPGCL
Eklahare,Nasik
ProcuremenUReplacement
Plan
OperationalError:
Delayin Maintenance:
Delayin bringingbackthe Ltnit:
Trainingof Staff:
Whetherremedialactionis completedsatisfactory& point is closed :
CE/Dy.CE(Works)