GE Power Systems
compressor [ews
Subject: Oil Pressure, Frame Group: os @ eo
Date: _ Nov, 41,2000 _Series:_H302
The frame lube system has been changed on the H302 to Improve the oll
pressure at lower operating speeds. The oll pump suction line from the sump
has been changed from ‘2" to 34” OD tubing. Also an oil cooler with a
thermostatic valve should be installed in the lube system to maintain the oil
temperature within the allowable operating limits of 140° F to 170° F. Parts
required are tube fittings (23-PS-7512 and SS22-PS-7511), oll cooler and 2”
thermostatic valve (150° F). Frames shipped after June 1, 2000 and serial
number H125 and up, will have the new pump suction line.
PRESSURE CONNECT ION
FOR GUAGE AND SWITCH
1
MALW BEARING I
a
ROSSHEAD
”
302 CRANKCASE Icrossne.
t e | |
suuP MAIN BEARING i
= =F pS Nara ne
sis ne We
soit
FILTER
are Te Lae Tue
PAK ep
«vor PRovineo BY GEMINI)
Gas Compressors