Tiang Pancang (24 Juli 2012)

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 8

PROYEK PEMBANGUNAN JALAN TOL NUSA DUA - NGURAH RAI - BENOA (PAKET - 03)

STA 5+308 - 6+902 (MAIN ROAD), SIMPANG SUSUN NGURAH RAI, JALAN AKSES NGURAH RAI (STA
0+000-STA 1+597)
DAN PERSIMPANGAN SEBIDANG JALAN NGURAH RAI

BAGAN ALIR
PEKERJAAN : PEMANCANGAN

AKTIVITAS :
h General Superintendant mengajukan
permohonan test pemancangan kepada
JBT

MULAI PEKERJAAN
Permohonan Test
Pemancangan

h QCM mengecek kesiapan pemancangan

h Test Pemancangan dilaksanakan

Diterima?

Tidak

h QCM mengevaluasi hasil test pemancangan


1. Panjang tiang
2. Final Set Rencana (Kalendering)
3. PDA

Ya

Pemancangan

h Kontraktor menyiapkan tiang pancang


sesuai kebutuhan

Evaluasi hasil
Pemancangan

h Pemancangan dilaksanakan

Pengadaan Tiang
Penentuan
Titik Pancang
Pengganti

Pemancangan

Gagal ?

h Pemancangan gagal karena tiang pancang


rusak , pecah, patah dan daya dukung.
QCM menentukan titik pancang pengganti

h Pemancangan berlanjut sampai mencapai


Final Set

Ya

Tidak

Pemancangan
Berlanjut

SELESAI

10

10

PROYEK PEMBANGUNAN JALAN TOL NUSA DUA - NGURAH RAI - BENOA (PAKET - 03)
STA 5+308 - 6+902 (MAIN ROAD), SIMPANG SUSUN NGURAH RAI, JALAN AKSES NGURAH RAI
(STA 0+000-STA 1+597) DAN PERSIMPANGAN SEBIDANG JALAN NGURAH RAI

ACTIVITY LIST
BAB

: 10 STRUKTUR BETON

SEKSI

: 10.05 TIANG PANCANG PRETENSIONED

Activity
No.

Contractor

Action
Engineer

Output

Verify

Issue

Submission

Check

Reject /
Approval

Check

Reject /
Approval

Check

Reject /
Approval

Verify

Verify

Verify

10.05.(3)b (iii)

Verify

10.05.(3)b (v)

Description of Activity

Specification
Clause

PRELIMINARIES :1

Related Works :
Excavation
Fill
Concrete work
Prestressed Concrete
Reinforcing Steel
Structural Steel
Demolition of Structures
Ensure that the Contractor has all the relevant data
and drawings available at Contract start-up.

Before commencing the contractor shall submit : a


detail program ; a detail proposed method; design

10.05.(3)b

calculation and proposal for test loading piles


CONSTRUCTION :-

Test
The Contractor shall furnish and execute test piles

The Contractor shall submit to the Engineer for


approval detailed drawings of the loading apparatus
he intends to use.
Storage and Protection
Units of reinforced or prestressed concrete and
steel units shall be stored clear of the ground on
timber supports placed on firm ground which is not
liable to subside, whether wet or dry, under the
weight of the units

Precast Concrete Piles


Piles shall be designed, cast, and cured to develop
the strength necessary to withstand the
transporting, handling and driving stresses without
damage. Square piles should have chamfered
corners. Hollow piles shall be used where
exceptional lengths are required
Pile Driving

Piles may be driven with any type of hammer,


provided they penetrate to the prescribed depth or
attain the specified resistance, without being
damaged
Piles bearing capacity should be checked through
calendering data for each pile, to make sure that the
piles installed have sufficient bearing apacity
compare to design bearing capacity.
1

Level of Approval
1
2
3

ACTIVITY LIST
BAB

: 10 STRUKTUR BETON

SEKSI

: 10.05 TIANG PANCANG PRETENSIONED

Activity
No.

Contractor

Action
Engineer

Output

Specification
Clause

Submission

Check

Agreement

10.05.(4)

Description of Activity

MEASUREMENT AND PAYMENT :Measurement and payment shall be in accordance


with the requirements of the specification.
10

Quantities shall be calculated by the Contractor and


checked by the Engineer.

Level of Approval
1
2
3

PROYEK PEMBANGUNAN JALAN TOL NUSA DUA - NGURAH RAI - BENOA (PAKET 03)
STA 5+308 - 6+902 (MAIN ROAD), SIMPANG SUSUN NGURAH RAI, JALAN AKSES
NGURAH RAI (STA 0+000-STA 1+597) DAN PERSIMPANGAN SEBIDANG JALAN
NGURAH RAI

MATERIALS AND TESTING


BAB

: 10 STUKTUR BETON

SEKSI

: 10.05 TIANG PANCANG PRETENSIONED

No.

Material Type

Test Requirements
Type of Test
Freg. of Test

Related
Lists

Specification
Clause

Reference
Standard

10.01.(1)b

MATERIALS :1

Timber
Sheet piles shall be made from sawn or hewn
timber, with square corners
Piles shall be made from sound wood completely
free from decay, loose knots, wind shakes,
unsound portions or insect attack

Concrete
Concrete shall conform to the requirements of
Section S10.01
Precast Prestressed Concrete
Precast prestressed concrete piles shall conform
10.01.(1)b
to the requirements of Section S10.01
Structural Steel Piles
Steel shall conform to the requirements of
Section 7.4

Steel Pipe
Pipes shall be of the diameter shown on the
Drawings. The wall thickness shall not be less
than that shown on the Drawings and shall not be
less than 4.8 mm

Each material shall be tested and comply with


the requirements specified in the relevant
section of the Specifications.

Refer to the
relevant Material
List above

PROYEK PEMBANGUNAN JALAN TOL NUSA DUA - NGURAH RAI - BENOA (PAKET - 03)
STA 5+308 - 6+902 (MAIN ROAD), SIMPANG SUSUN NGURAH RAI, JALAN AKSES NGURAH RAI
(STA 0+000-STA 1+597)
DAN PERSIMPANGAN SEBIDANG JALAN NGURAH RAI

BAB

: 10 STRUKTUR BETON

SEKSI

: 10.05 TIANG PANCANG PRETENSIONED

Format DP

TIANG PANCANG ( DRIVEN PILE)

Pemancangan

Tiang Pancang
Beton

Tipe :
Berat Ram : ton

Hammer

Jenis tiang pancang


Lokasi

Disungai
Disungai
Tunggal
Titik No :

Didarat
Kelompok
Kode Klp. :
Jumlah
:
Titik No
:

Tiang

Posisi Tiang

Tegak
:

Penyambungan :
L1 + L2

: menit

Ukuran/dimensi tiang :
Tanggal cor tiang

Panjang tiang
dipancang

: L1 =
L2 =
L3 =
Total

Level pemotongan
(CL = cut off level )

:+

Miring 1 : .

Tanggal dipancang

Baja

.
.
.
.

(L1+L2)+L3 : menit
Laporan Kegiatan Pemancangan
Tiang masuk tanpa dipukul m
Masuk
Jumlah
Masuk
Jumlah
Masuk
(m)
Pukulan
(m)
Pukulan
(m)

Gambar Sketsa

Jumlah
Pukulan

CL
MT

Kemungkinan 2

Kemungkinan 1

CL

Final set mm/pukulan. Tinggi jatuh Ram m


Data kalendering 3 x 10 pukulan terakhir dilampirkan.

11

m
m
m
m

PROYEK PEMBANGUNAN JALAN TOL NUSA DUA - NGURAH RAI - BENOA (PAKET - 03)
STA 5+308 - 6+902 (MAIN ROAD), SIMPANG SUSUN NGURAH RAI, JALAN AKSES NGURAH RAI (STA 0+000-STA
1+597) DAN PERSIMPANGAN SEBIDANG JALAN NGURAH RAI

DAFTAR PERIKSA
BAB
SEKSI

:
:

10
10.05 (02)

STRUKTUR BETON
TIANG PANCANG BETON PRETENSIONED

Lokasi

............................................................

Tanggal Request

.............................................................

Tanggal Pelaksanaan

.............................................................

CATATAN

Persiapan
1.1 Tiang pancang dilengkapi dengan sertifikat
kelaikan produksi

1.2 Request of work dilengkapi dengan


lokasi titik pemancangan

1.3 Request of work dilengkapi dengan


metode pelaksanaan

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

1.4 Request of work dilengkapi dengan


perhitungan pemancangan

Ada

Tidak Ada

1.5 Penumpukan tiang berdasarkan


urutan titik-titik pemancangan

Ada

Tidak Ada

1.6 Jenis dan ukuran sesuai gambar

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Penentuan Panjang Tiang


2.1 Berdasarkan Gambar Rencana

2.2 Berdasarkan Hasil Penelitian Tanah

2.3 Berdasarkan hasil percobaan


pemancangan dilapangan

Peralatan dan Operator

3.1 Diesel Hammer

3.2 Berat Ram Hammer sesuai berat tiang

3.3 Spesifikasi alat

3.4 Manual Pengoperasian Alat

3.5 Program Pemeliharaan

3.6 Sertifikat Operator Pancang

3.7 Sertifikat Operator Las

3.8 Spesifikasi alat Ukur

3.9 Sertifikat Surveyor

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Ada

Tidak Ada

Pemancangan
4.1 Urutan titik pemancangan pada
kelompok tiang dimulai dari titik terluar

4.2 Daya dukung tiang ditentukan dengan


Metode Dinamic Formula sesuai tabel

4.3 Grafik final set pada 10 kali pukulan


terakhir (kalendering)

4.4 Selama pemancangan ketegakan tiang


diamati dari dua arah

4.5 Pemancangan dilengkapi dengan


catatan proses pemancangan

Penyambungan
5.1 Penyambungan tiang dengan las 3 lapis

5.2 Kawat las sesuai spesifikasi

Mengetahui :
Diperiksa dan Disetujui Oleh :
Pengguna Jasa
Konsultan Quality Assurance
PT. JASAMARGA BALI
PT. YODYA KARYA KSO
TOL

Diperiksa Oleh :
Quality Control Management
QCM

Diajukan Oleh :

.........................................
........................................
...

.........................................

.............................................

Penyedia Jasa

WIKA - ADHI - HUTAMA JO

You might also like