Reference: IS 2911(Part 1/Sec 3)-2010 ( Design for Bored cat in situ Pile)
DATA:
Type of Pile: Bored cast in situ.
Dia. Of pile =1.20m (Normally adopted for Bridge work)
Length of Pile below pile cap=18.0m
Depth of top of pilecap below ground level=45cm.
Grade of Concrete: M35
Reinforcement Grade: Fe 500.clear cover to main reinforcement: 75mm
Soil Parameters:
Dry density of soil
=18KN/m3
Submerged density of soil = 10 KN/m3
Angle of internal friction = 28 degree. Angle of wall friction between pile and soil =22.5
deg. (maximum as per code)
Cohesion = Nil.
DESIGN:
Vertical Load Carrying capacity of pile :
As per Appendix B.1 of Is2911(Part 1/Sec 2)-2010
= x 1.22/4= 1.131 m2
=1.20m
E= Modulus of elasticity of concrete= 5000 sqrt 35 = 29580 MPa for M35 concrete.
I=Moment of Inertia of pile in cm4 =3.14 x 1.24 x/64 = 0.1018 m4
=( For medium sand in submerged condition)=0.525kg/cm2