Water Treatment Plant P ID Reference

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

Drawing Set for

The Forsyth County


Water Treatment Plant Expansion
12.0 MGD - ZEEWEED 1000

Project Number: 500408

12

11

10

VALVE & GATE SYMBOLS

LINE DESIGNATION

LINE SYMBOLS & MISC.

EQUIPMENT SYMBOLS

(SIZE,SCHEDULE,MATERIAL)

H
P&ID LINE TYPES
NORMALLY

NORMALLY

CLOSED

OPEN

INSTRUMENTATION LINES

RESIN TRAP

COMPRESSOR
PISTON

DIAPHRAGM

BLOWER
(GENERIC)

PUMP
(GENERIC)

DIAPHRAGM
PUMP

I/P CONVERTER
(ELECTRIC ANALOG TO
PNEUMATIC SIGNAL CONVERTER)

MAIN PROCESS LINE

EX.

MOST COMMON MATERIALS

MECHANICAL LINK
EQUIPMENT/LINE
SUPPLIED BY OTHERS

Y STRAINER
ULTRASONIC/ELECTROMAGNETIC

BALL
COMPRESSOR
ROTARY SCREW

CENTRIFUGAL
PUMP

LOBE BLOWER

METERING
PUMP

SKID BOUNDARY

INSTRUMENT CONNECTION

FUTURE EQUIPMENT

ELECTRIC SIGNAL (ANALOG OR


DIGITAL)

BALL (MANUAL)
GATE OR OTHER
IN-LINE TYPE
NOT OTHERWISE
IDENTIFIED

STEAM TRAP

TURBINE

SCH.40, C.S.

SCH.80, CPVC

P.E. TUBING

SCH.10, 316L SS

SS TUBING

SCH.40, 316L SS

NYLON TUBING

SCH.10, 304L SS
SCH.40, 304L SS

CYLINDRICAL STRAINER

G
FLOOR DRAIN

POSITIVE
DISPLACEMENT
PUMP

SCH.80, PVC

PNEUMATIC SIGNAL

REVISED ITEM

CENTRIFUGAL
BLOWER

4", SCH.80, PVC

CONICAL OR
TEMPORARY STRAINER

PROCESS LINE

BUTTERFLY

SIZE (x"), SCHEDULE, MATERIAL

CLIENT INTERFACE SIGNALS

SOFTWARE LINK

VACUUM PUMP
(WET OR DRY)

OTHER COMBINATIONS OF ANALOG/DIGITAL & DATA HIGHWAY


COMMUNICATION MUST ALSO BE SHOWN AS REQUIRED

THERMOWELL

OPTIONAL ITEM

CAPILLARY TUBING

GLOBE

SIGNAL
PI

CALCULATED VALUE

PLUG OR ANGLE
SEAT

AIR DRYER

REGENERATIVE
BLOWER

TURBINE
PUMP

PIG TAIL

AXIAL FLOW
PUMP

FROM

LOCAL PANEL
TERMINATION TAG

FLEXIBLE HOSE
SIGNAL

NEEDLE

DESICCANT
DRYER

PINCH

CAN
PUMP

PIPING SPOOL TAG

ELECTRIC TRACE
& INSULATION

SUBMERSIBLE
PUMP

NON-FLEX CONNECTION
TO

F
REVISION TRIANGLE

VICTAULIC CONNECTION

CONTINUATION SYMBOLS

COMMON ABBREVIATIONS

CAMLOCK CONNECTION

KNIFE GATE
P&ID TIE - INS
M

IAS

FLANGED CONNECTION

EX.
PERMEATE

BLIND FLANGE

XXXXXX-D-XXX

SLIDING GATE

TO STORAGE TANK TK-XX


XX USGPM

INSTRUMENT AIR SUPPLY

SP

SET POINT

MCC

MOTOR CONTROL CENTER

MAG

CAPPED CONNECTION

MAGNETIC

HOA

HAND-OFF AUTO

LOR

LOCAL-OFF REMOTE

E-STOP EMERGENCY STOP

DI

GENERAL INSTRUMENT AND FUNCTION SYMBOLS

SOLENOID VALVE

GRANULAR ACTIVATED
WATER SOFTENER

PORTABLE
EXCHANGE TANK

MEMBRANE MODULES
& HOUSING
(IF REQD)

UV STERILIZER

CARBON FILTER (GAC)


OR MULTI MEDIA

HH

FILTER (MMF)

SAMPLE VALVE

AUXILIARY

LOCATED ON
SKID CONTROL

FIELD

LOCATION

PANEL

MOUNTED

NORMALLY

LA

PLC ALARM FUNCTION WITH


MULTIPLE TRIGGER POINTS

LL

SEE INSTRUMENT LETTERS

DIGITAL INPUT

DO

ANALOG INPUT

AO

ANALOG OUTPUT

FF

SUMMING

DIGITAL OUTPUT

AI

FOUNDATION FIELD BUS

D.NET

DEVICE NET

ACCESSIBLE TO
OPERATOR

CHECK
HEAT
EXCHANGER

HEATING/
COOLING
COIL

HEATER

BACKFLOW
PREVENTER

AVERAGING

S/n

DISCRETE

INSTRUMENTS SHARING
COMMON HOUSING

INSTRUMENTS

LOW
SELECTING
HUMAN MACHINE

PILOT LIGHT

INTERFACE HMI

INJECTION QUILL
POSITIVEDISPLACEMENTTYPE FLOW
TOTALIZING
INDICATOR

PADDLEWHEEL
FLOWMETER

D
THREE WAY

FOUR WAY

VENTURI
FLOWMETER

RUPTURE DISC
(PRESSURE)

RUPTURE DISC
(VACUUM)

FLUME

COMPUTER/DCS

UNDEFINED
INTERLOCK LOGIC

FUNCTION

UNSPECIFIED
FUNCTION

f(x)

CALIBRATION
COLUMN

ORIFICE PLATE
IN QUICK-CHANGE
FITTING

FLOWMETER
VORTEX OR
MAGNETIC
(TYPE INDICATED)

HIGH
SELECTING

ROTAMETER
(VARIABLE AREA
FLOWMETERS)

PROGRAMMABLE

ROTAMETER WITH
BUILT-IN HAND
CONTROL VALVE

SYSTEMS WITH
MULTIPLE PLCS

VALVE & GATE ACTUATOR SYMBOLS

FLOW
STRAIGHTENING
DEVICE

ORIFICE PLATE

PLC-X

LOGIC CONTROL

NOTE: ON LOSS OF PRIMARY POWER


(PNEUMATIC, ELECTRICAL OR HYDRAULIC)
XX: FC = FAIL CLOSED
FO = FAIL OPEN
FL = FAIL TO LAST POSITION

IF NOT SPECIFIED ASSUME FC.

VACUUM BREAKER

MUFFLER

STATIC MIXER

FIXED
SCREEN

VENT AND
FILTER

PNEUMATIC DIAPHRAGM

TRAVEL STOP

DOUBLE ACTING PNEUMATIC


CYLINDER (INST.AIR LINES
NOT ALWAYS SHOWN)

VALVE POSITIONER

DIFFUSER GRID

AUTOMATIC AIR VENT


DIAPHRAGM
SEAL

EDUCTOR/
EJECTOR

PULSATION
DAMPENER

PRESSURE REGULATOR

SILENCER
OR FILTER

MIXER

SPRING CLOSE PNEUMATIC


CYLINDER (INST.AIR LINES
NOT ALWAYS SHOWN)

CARTRIDGE
FILTER

HAND OVERRIDE

SPRING OPEN PNEUMATIC


CYLINDER (INST.AIR LINES
NOT ALWAYS SHOWN)

B
BACK PRESSURE REGULATOR

M-

M-

M-

M-

ACTUATOR WITH
TRAVEL STOP

M-

SOLENOID

PRESSURE RELIEF/
MULTI FUNCTION VALVE

07/09/13

REV.

ELECTRIC MOTOR
(DIGITAL- OPEN/CLOSED)

I.B.

DESCRIPTION

ZONE

M.D.

DSGN

APPD

DATE

APPROVAL

M-

FLOAT CONTROLLED

ISSUED FOR APPROVAL

DATE

(Y/M/D)

DRWN:

A.P.L.

07/04/20

DSGN:

K.S.

07/04/20

CHKD:

N.K.

07/09/12

APPD:

M.D.

07/09/12

WPR-

MUD

WASHPACTOR

GRIT WASHER/
CLASSIFIER

PERFORATED
TRAVELLING
BAND SCREEN

ELECTRIC MOTOR
(ANALOG - CONTROL)

BASKET STRAINER
(MOTOR OPTIONAL)

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

ISA SYMBOLOGY COVER SHEET


A

CADD FILE:

500408L1 1.DGN
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.
IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-L-001
2

SHEET

REV.

1 OF 2

12

11

10

ISA TEXT ABBREVIATIONS


MEASURED OR
INDICATING VARIABLE

ANALYSIS

BURNER, COMBUSTION

USERS CHOICE

USERS CHOICE

VOLTAGE

FLOW RATE

MODIFIER

READOUT OR
PASSIVE FUNCTION

MECHANICAL OR INSTRUMENT DEVICE TAG IDENTIFICATION PREFIX

OUTPUT FUNCTION

ALARM
USERS CHOICE

AV

AIR VENT

AC

AIR COMPRESSOR

MODIFIER

AE/AIT
USERS CHOICE

USERS CHOICE

AE/AT

CONTROL

DIFFERENTIAL

BPV
SENSOR
(PRIMARY ELEMENT)

DR

AIR DRIER

USERS CHOICE

HAND

TIME RATE OF CHANGE

USERS CHOICE

FG

FLOW SIGHT GLASS

FI

FLOW INDICATOR

FO

ORIFICE PLATE

FV

AUTOMATIC VALVE

FX

FLOW STRAIGHTENING DEVICE

CONTROL STATION
LIGHT

USERS CHOICE

LOW

MOMENTARY

PRESSURE, VACUUM

QUANTITY

USERS CHOICE

USERS CHOICE

USERS CHOICE

ORIFICE, RESTRICTION
POINT (TEST)
CONNECTION

H
HC

INTEGRATE, TOTALISE

RADIATION

SPEED, FREQUENCY

TEMPERATURE

MULTIVARIABLE

VIBRATION, MECHANICAL
ANALYSIS

WEIGHT, FORCE

UNCLASSIFIED

X AXIS

EVENT, STATE OR
PRESENT

Y AXIS

HCV

RECORD
SAFETY

SWITCH
TRANSMIT
MULTIFUNCTION

MULTIFUNCTION

WELL
AVERAGE

UNCLASSIFIED

UNCLASSIFIED

RELAY, COMPUTE,
CONVERT

Z AXIS

UNCLASSIFIED FINAL
CONTROL ELEMENT

LEVEL ELEMENT WITH LEVEL TRANSMITTER


LEVEL SIGHT GLASS
LEVEL INDICATOR

LS*

LEVEL SWITCH

MFV

MULTI FUNCTION VALVE (COMBINATION RELIEF & BACKPRESSURE VALVE FOR METERING PUMPS)

P
PD
PE/PIT
PE/PT
PI

MIXER
STATIC MIXER
PUMP

PULSATION DAMPENER
PRESSURE ELEMENT WITH PRESSURE INDICATING TRANSMITTER
PRESSURE ELEMENT WITH PRESSURE TRANSMITTER
PRESSURE INDICATOR

PRV

PRESSURE REGULATING VALVE

PS*

PRESSURE SWITCH

PSE

RUPTURE DISC

PSV

PRESSURE RELIEF VALVE

RT
SCR
SG
STR
SV
TCV
TE/TIT
TE/TT

LEVEL ELEMENT WITH LEVEL INDICATING TRANSMITTER

LI

MXS

LEVEL CONTROL VALVE

LG

MX

HAND CONTROL VALVE

HAND VALVE

DRIVER, ACTUATOR,
POSITION, DIMENSION

HEATING COIL

HEAT EXCHANGER

LE/LIT

VALVE, DAMPER,
LOUVER

HEATER

HV
LCV

MULTIFUNCTION

GRIT WASHER/CLASSIFIER

HE

LE/LT

MIDDLE, INTERMEDIATE

GWC
P

FLOW ELEMENT WITH FLOW TRANSMITTER

SCAN

LEVEL

LOG REMOVAL

FLOW ELEMENT WITH FLOW INDICATING TRANSMITTER

INDICATE

POWER

FLOW CONTROL VALVE

HIGH

CURRENT (ELECTRICAL)

TIME, TIME SCHEDULE

FILTER

GLASS, VIEWING DEVICE

FE/FT
J

RATIO (FRACTION)

FE/FIT
I

BACK PRESSURE VALVE


CHECK VALVE/INJECTION QUILL

FCV
H

ANALYSIS ELEMENT WITH ANALYSIS TRANSMITTER


BLOWER

CV

F
G

ANALYSIS ELEMENT WITH ANALYSIS INDICATING TRANSMITTER

RESIN TRAP

SCREEN
SIGHT GLASS
STRAINER
SAMPLE VALVE
TEMPERATURE CONTROL VALVE
TEMPERATURE ELEMENT WITH TEMPERATURE INDICATING TRANSMITTER
TEMPERATURE ELEMENT WITH TEMPERATURE TRANSMITTER

TI

TEMPERATURE INDICATOR

TK

TANK

TS*

TEMPERATURE SWITCH

TURB

TURBINE

UV
VB

UV STERILIZER
VACUUM BREAKER

VS*

VIBRATION SWITCH

WPR

WASHPACTOR

YY

07/09/13

REV.

ISSUED FOR APPROVAL

DATE

M.D.

DSGN

APPD

(Y/M/D)

DRWN:

A.P.L.

07/04/20

DSGN:

K.S.

07/04/20

CHKD:

N.K.

07/09/12

APPD:

M.D.

07/09/12

SOLENOID FOR PNEUMATIC CONTROL OF AUTOMATIC VALVE

ZONE

DATE

APPROVAL

* ADD THE SUFFIX HH (HIGH HIGH), H (HIGH), L (LOW), LL (LOW LOW) AS REQUIRED FOR THESE ITEMS.

I.B.

DESCRIPTION

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

ISA SYMBOLOGY COVER SHEET


A

CADD FILE:

500408L1 2.DGN
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.
IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-L-001
2

SHEET

REV.

2 OF 2

12

11

10

G
SEALWEIR
P-3500-1 TO 6
(7 TO 11 FUTURE)
PROCESS PUMP

STR-7600 A

CLEARWELL
FEED
CHANNEL
CLARIFIED WATER

(BY OTHERS)

F
STR-7600 B

TK-3500-1 TO 6

TK-8800

(7 TO 11 FUTURE)

BACKPULSE TANK

MEMBRANE TANK
(BY OTHERS)

STR-7600 C
STR-7600 A - SELF-CLEANING STRAINER
B-8500A/B

STR-7600 B - BASKET STRAINER

BACKWASH WASTE

STR-7600 C - SELF-CLEANING STRAINER (FUTURE)

TO BACKWASH
RECOVERY BASINS
NEUTRALIZED
CHEMICAL WASTE

TO RESIDUALS
HOLDING BASINS

SODIUM

SODIUM

BISULFITE

HYDROXIDE

P-5300 A/B

P-5500 A/B

ELECTRIC

WATER
HEATER

P-9700A/B

TK-9700

CIP PUMPS

CIP TANK

07/09/13

REV.

APPROVAL

SODIUM

CITRIC

HYPOCHLORITE

ACID

P-5100 A/B

P-6500 A/B

ISSUED FOR APPROVAL

DATE

M.D.

DSGN

APPD

DATE

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/20

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

ZONE

(Y/M/D)

P-6600 A/B

I.B.

DESCRIPTION

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PROCESS FLOW DIAGRAM


A

500408A001.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-A-001
2

SHEET

REV.

1 OF 1

12

11

10

H
3

SCREEN WASH WATER

FROM PLANT SERVICE

SCREENED CLARIFIED
WATER

CLARIFIED WATER
36" CLD1

36", SCH.10, 304L SS


500408-D-001 SHT.2

FROM SEDIMENTATION
TANK OR SUPERPULSATOR

HV-7587
6"

12 MGD
24 MGD (FUTURE)
STR-A

FV-7637
1/2"

SCREENED CLARIFIED
SAMPLE

(SEE NOTE 5)

500408-D-015

PI

PI

7641B

7640B

M-7600B

HV-7641B

HV-7640B

1"
2

HV-7681B

30"

HV-7680B

STR-7600B
0.5mm 2
BASKET STRAINER
RATED FLOW: 9365 GPM
CLEAN PRESSURE DROP:
0.40 PSIG @ 12410 GPM
STANDBY

1"
2

30"

HV-7660B
2"

09/11/04

REVISED AS NOTED

X.C.

M.D.

08/04/01

REVISED AS NOTED

X.C.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

REV.

DATE

HIS

STR-C
(SEE NOTE 5)
YS
NOTES:
DO

1. ALL DOTTED LINES/EQUIPMENT


BY OTHERS

S
2. STRAINER CONTROLLED BY LOCAL
PANEL, NOT ZENON PLC.

4. 900 GPM @ 40 PSIG NEEDED FOR


BACK WASHING.

3
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.

5. STRAINER SYSTEM SUPPLIED AND


CONTROLLED BY OTHERS.

IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

I.B.

07/04/27

DSGN:

K.S.

07/04/20

CHKD:

N.K.

07/09/12

APPD:

M.D.

07/09/12

12

11

1:1

10

APPD

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


PRE-TREATMENT
SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

D(24x36)

CUSTOMER:

500408D1 1.DGN

SCALE:

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

M.D.

DSGN

(Y/M/D)

DRWN:

CADD FILE:

ZONE

DATE

APPROVAL

3. INCLUDED WITH STRAINER PACKAGE

TYP. SOLENOID VALVE


CONTROL DETAIL

I.B.

DESCRIPTION

DRAWING NO.

500408-D-001
2

SHEET

REV.

1 OF 2

12

11

10

PERMEATE
10", SCH.10, 304 SS
500408-D-013

BY OTHERS

OVERFLOW
42", SCH.10, 304L SS

TO BACKWASH
RECOVERY BASINS

LA

LY

LI

LL

7626

7626

7626

7626

AI

TK-7600
FEED CHANNEL

LIT
7626

RANGE: 0-60"

LE
7626

SCREENED CLARIFIED
WATER
30", SCH.10, 304L SS
500408-D-001,SHT.1

HV-7626
1"

D
MULTIPLE
LINES

SCREENED CLARIFIED
WATER
18", SCH.10, 304L SS
500408-D-003

TO MEMBRANE TANKS

NOTE:
1. ALL DOTTED LINES/EQUIPMENT

08/04/01

REVISED AS NOTED

X.C.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

REV.

DATE

I.B.

DESCRIPTION

ZONE

M.D.

DSGN

APPD

BY OTHERS
APPROVAL

DATE
(Y/M/D)

DRWN: A.P.L.

07/04/20

DSGN: K.S.

07/04/20

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


DISTRIBUTION CHANNEL

500408D1 2.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-001
2

SHEET

REV.

2 OF 2

12

11

10

KQI

HIS

YL

8500A

8500A

8500A

KQ

YA

ACCUSTIC HOOD

FLL

8500A 8500A
DI

YS

SC

SMY

HA

8500A

8500A

8500A

8500A

DO

AO

8506A

DI
HOA

JS

SC

HS

8500A

8500A

8500A

FAL
8506A
DI
PI
S.P.= 110 SCFM
8540A

M-8500A

DECREASING

FSL

HV-8540A

8506A

1/2"

AIR SCOUR

"

3",SCH.10, 304L SS

3", SCH.10, 304L SS

3", SCH.10, 304L SS


500408-D-003

PSV-8582A

INLET FILTER

DISCHARGE

AND SILENCER

(SEE NOTE 4)

HV-8580A

CV-8585A

S.P.= 11 PSIG

TO TK-3400

MULTIPLE
LINES

SILENCER
B-8500A

(SEE NOTE 3)

ACCUSTIC HOOD

KQI

HIS

YL

8500B

8500B

8500B

E
KQ

YA

8500B 8500B
DI

YS

SC

SMY

HA

8500B

8500B

8500B

8500B

DO

AO

FLL
8506B

DI
HOA

JS

SC

HS

8500B

8500B

8500B

FAL
8506B
DI
PI
S.P.= 110 SCFM
FSL

8540B

M-8500B

DECREASING

8506B

HV-8540B
1/2"

"

3",SCH.10, 304L SS

INLET FILTER

DISCHARGE

AND SILENCER

3", SCH.10, 304L SS

(SEE NOTE 4)

PSV-8582B

CV-8585B

S.P.= 11 PSIG

HV-8580B

SILENCER
B-8500B
(SEE NOTE 3)

B-8500A/B
MEMBRANE BLOWERS
131-223 SCFM @ 5.32 TO 5.75 PSIG
10 HP 3600 RPM
480 V/ 3 PH/ 60 HZ

B
NOTE:
1. ALL DOTTED LINES/EQUIPMENT

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

I.B.

M.D.

BY OTHERS.
REV.

DATE

DESCRIPTION

ZONE

DSGN

APPD

2. ZENON TRAIN 1 TAGS SHOWN.


APPROVAL

DATE
(Y/M/D)

3. INCLUDED WITH BLOWER PACKAGE.


DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

4. ESTIMATED BLOWER DISCHARGE AIR


TEMPERATURE IS 150^F. PROVIDE
PROTECTION ON PIPING IS NECESSARY
(BY OTHERS).
5. LOW POINT DRAINS & HIGH VENT POINTS
2

BY OTHERS.

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


P.D. BLOWERS & ASSOC. EQUIPMENT

500408D002.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-002
2

SHEET

REV.

1 OF 1

12

11

10

AIR SUPPLY ASSEMBLY

EJECTOR ASSEMBLY
NOTE 3

AIR SUPPLY

YS

"

9267-1

NPS-F
" ODT,

",SCH.40, 304L SS

DO
INSTRUMENT AIR

PP TUBING
PI

(BY OTHERS)

13.5 SCFM @ 80 PSIG

9240-1

MIT AIR

500408-D-012

1", SCH.10, 304L SS


500408-D-012

HV-3466-1

FROM AC-9100 A/B

FV-3467-1

FV-9268-1

HV-9291-1

1"

1"

FV-9267-1

HV-9290-1

"

"

F-9200-1

FROM AC-9100 A/B

"

P-9200-1
VACUUM EJECTOR

1"

(FOR PRIMING)

PDA

PDC

PDIC

PDC

8823-1 8823-1 3423-1

1",SCH.40,

EXHAUST

304L SS

1" FLEX HOSE


OR PVC

8823-1

(BY OTHERS)
PDA

PDIC

PDL

3423-1

3423-1

LL 3423-1
PDA

PDL

8123-1

8823-1

PDL

LL
H

PERMEATE/BACKPULSE

TMP

12", SCH.10, 304L SS

12", SCH.10, 304L SS

TO P-3500/FROM
BACKPULSE SYSTEM

8123-1

HH
LIC

LI

LL

3426-1 3426-1 3426-1

500408-D-005

H
L
LL
OVERFLOW TO

HV-3482A-1

HV-3482B-1

10"

10"

DISTRIBUTION
CHANNEL

HH
LC

LY

LA

3426-1 3426-1 3426-1

H
L
LL

AI
LIT

HIS

LE
3426-1
RANGE:

ZC

4 TO 140 IN

3463-1

CASSETTE B-1

3426-1

3463-1

CASSETTE A-1

AO

I
P

IAS

HV-3426-1
1"

SCREENED CLARIFIED
WATER

TK-3400-1
MEMBRANE TANK

18", SCH.10, 304L SS

2 ZW-1000 v3 CASSETTES OF 51/60 MODULES PER TRAIN

500408-D-001,SHT.2

CONCRETE CONSTRUCTION
HV-3463-1

FROM DISTRIBUTION
CHANNEL

FCV-3463-1
BAFFLE PLATE
(BY OTHERS)

HV-3484A-1

HV-3484B-1

2"

2"

AIR SCOUR
3", SCH.10, 304L SS

(SEE NOTE 4)

500408-D-002

3", SCH.10, 304L SS

FROM B-8500 A/B

FV-3473-1
CIP / DRAIN
6", SCH.80, CPVC
500408-D-010

ZC

FV-9761B-1

FV-9761A-1
3463-1

RECIRCULATION RETURN/
TANK DRAIN FOR CLEAN

AO

FV-9761C-1
2"

I
HIS

F.O.

IAS

3463-1
BACKWASH WASTE
18", SCH.10, 304L SS

FCV-3863-1
HV-3887-1

TO BACKWASH
RECOVERY BASINS

1"
HIS
HIS

YS

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

YS

DO

NOTES:
EXHAUST

DO
1. ALL DOTTED LINES/EQUIPMENT

BY OTHERS.

S
IAS

REV.

DATE

2. DRAWING TYPICAL FOR TRAINS 1 TO 6.


APPROVAL

ZENON TRAIN 1 TAGS SHOWN.

FC

3. EJECTORS TO BE LOCATED AT HIGH POINT

I.B.

DESCRIPTION

ZONE

M.D.

DSGN

APPD

DATE
(Y/M/D)

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

IN PIPING
4. A PORTION OF THE AIR HEADER NEEDS
TO BE LOCATED ABOVE THE HIGHEST

TYP. PNEUMATIC ACTUATED


VALVE CONTROL DETAIL

CUSTOMER:

WATER LEVEL IN THE MEMBRANE TANK.

ANGLE SEAT VALVE


CONTROL DETAIL

CADD FILE:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


MEMBRANES & ASSOC. EQUIPEMENT

500408D003.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-003
2

SHEET

REV.

1 OF 1

12

11

10

10", SCH.10, 304L SS

HIS

YL

TLH

3500-1 3500-1 3500-1

HH

HH
H
L

PL

PI

YA

3523-1 3523-1

YS

SC

SM

HA

TAH

DO

FQI

PLH
HOA

HH
8807-1

H
L

PA

PY

JS

KQI

SC

HOA
HS

PAH

RANGE:

DI

-15 TO 15 PSIG

PSH

FIC

FL

3520-1

FQ

FQI

3522-1

3522-1

3522-1

FL
3522-1

8820-1 L
FQM

"

3520-1

8820-1
FQJ
PERMEATE

8820-1

10", SCH.10, 304L SS

10"

12", SCH.10, 304L SS

FA

0 TO 2000 GPM
8"

"

FC

HV-3540-1

3500-1

HV-3541-1

FQMI
3522-1

8820-1

RANGE:

JC
M-3500-1

8807-1

FQM
3522-1

FE

3540-1

3500-1

3541-1

3523-1

FIC
3522-1

FQ

AI

PI

TSH

PI

FC
3522-1

3520-1

FIT

8820-1 8820-1 L

PE

FQJI
3522-1

FY

FQJI

3523-1

BACKPULSE

FFMY

FJ

3520-1 3520-

PIT

8807-1

8820-1 8820-1
FV-8860-1

S.P.= 11 PSIG

HH

L
3520-1 LL

FJI

3520-1 3520-1

AI

PERMEATE/

FA

3500-1 3500-1 3500-1 3500-1 3500-1

LL

INCREASING

3520-1

FL

YL
FQMI

3523-1 3523-1

3520-1

LL 3520-1

DI

AO

FC

3500-1 3500-1 3500-1 3500-1 3500-1 3500-1

LL
DI

FIC

FQJ
3522-1

10", SCH.10, 304L SS

500408-D-013

500408-D-003

CV-3585-1
HV-3586-1

HV-3587-1

1"

P-3500-1

(SEE NOTE 3)

1"

TO COMMON PERMEATE
HEADER

FV-3560-1

MAG
S

FV-3561-1

FROM/TO MEMBRANES

FV-3536A
PROCESS PUMP

"

1871 GPM @ 41.2 FT


30HP, 880 RPM
480 V/ 3 PH/ 60 HZ

PERMEATE SAMPLE
1/2", P.E. TUBING

FV-8861-1

500408-D-015

BACKPULSE WATER
12", SCH.10, 304L SS
500408-D-007

FROM BACKPULSE TANK

HIS

HIS

YS

1. ALL DOTTED LINES/EQUIPMENT


DO

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

NOTES:

EXHAUST

BY OTHERS

YS

I.B.

M.D.

2. DRAWING TYPICAL FOR TRAINS 1 TO 6.


REV.

ZENON TRAIN 1 TAGS SHOWN.

DATE

IAS
APPROVAL

3. 5 PIPE DIAMETERS UPSTREAM, 3 PIPE

DO

DESCRIPTION

ZONE

DSGN

APPD

DATE
(Y/M/D)

DIAMETERS DOWNSTREAM, STRAIGHT PIPE


RUN RECOMMENDED FOR MAXIMUM ACCURACY.

TYP. PNEUMATIC ACTUATED


VALVE CONTROL DETAIL

TYP. SOLENOID VALVE


CONTROL DETAIL

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


PROCESS PUMP & ASSOC. EQUIPMENT

500408D005.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-005
2

SHEET

REV.

1 OF 1

12

11

10

G
2

PERMEATE
6", SCH.10, 304L SS
500408-D-013

HV-8871

FROM COMMON
PERMEATE HEADER

FV-8870
POTABLE WATER
2"(50mm), SCH.80 PVC

HV-8890

FROM PLANT SERVICE


WATER SOURCE
2

SODIUM HYPOCHLORITE
FOR BIOGROWTH PREVENTION
", SCH.80, CPVC
500408-D-011,SHT.1

FROM P-51002

HV-5696 CV-5685 FV-5677

VENT C/W

HV-5697
"

AIR FILTER
F-8800

F
2

HH

H
L

LI
8826

SCH.80,PVC

LL

HH
2

LA

LY

8826

8826

LL

TK-8800

8",

LL
8826

AI

BACKPULSE TANK

RANGE:

2,000 USGAL

12" TO 100"

CT - 2000
PE CONSTRUCTION
CV-8898

LE

LIT

8826

8826

HV-8826
BACKPULSE WATER

1"

12", SCH.10, 304L SS


500408-D-005

(SEE NOTE 2)
HV-8884

HV-8895

TO MEMBRANES

STR-8800

4"
MULTIPLE LINES

HIS

YS

DO

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

NOTES:

EXHAUST

I.B.

M.D.

1. ALL DOTTED LINES/EQUIPMENT


REV.

BY OTHERS

DATE

IAS
2. PIPE SPOOL FOR STRAINER MAINTENANCE/

APPROVAL

DESCRIPTION

ZONE

DSGN

APPD

DATE
(Y/M/D)

REMOVAL AND ISOLATION VALVE ACTUATION.

TYP. PNEUMATIC ACTUATED


VALVE CONTROL DETAIL

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


BACKPULSE TANK & ASSOC. EQUIPMENT

500408D007.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-007
2

SHEET

REV.

1 OF 1

12

11

10

M-9200A

2", SCH.80, CPVC

2", SCH.80, CPVC

(SEE NOTE 4)

PI

9243

9241

FV-9200A
FV-9292A

(SEE NOTE 5)

"

P-9200A

(TYP.)

(SEE NOTE 6)

SEE NOTE 2

(TYP.)

HCV-9292A

(TYP.)
TO
ATMOSPHERE

FV-9262D

HV-9243

HV-9241

1"

"

AIR/VACUUM

(TYP.)

FROM
ATMOSPHERE

FROM ATM.
PI

FV-9261A

"

1", SCH.80, CPVC

3", SCH.80, CPVC

3", SCH.80, CPVC

500408-D-003

FV-9262A

FROM AIR RELEASE VALVE

(SEE NOTE 3)

FV-9262B
2"

2"

(SEE NOTE 3)

(TYP.)

(TYP.)

MULTIPLE LINES

LSH
"

TK-9200

9202-1

DI

LAH
9202-1
M-9200B

LG

LIQUID

2", SCH.80, CPVC

RESERVOIR

92-1

2", SCH.80, CPVC

LLH

30 GAL

FV-9261B
S

9202-1

FV-9200B
FV-9292B
"

P-9200B

FV-9262C

TO
ATMOSPHERE

2"

M-9200C

FV-9261C

2", SCH.80, CPVC

2", SCH.80, CPVC

FV-9200C
FV-9292C
"

P-9200C
VACUUM PUMPS

TO
ATMOSPHERE

2 DUTY + 1 STANDBY

67 CFM @ 25.12" HG @ 1206 FASL


7.5 HP, 3600 RPM
480 V / 3 PH / 60 Hz

HIS

YL

YA

YS

HIS

NOTES:

HIS

HA

1. ALL DOTTED LINES/EQUIPMENT

YS

DO

BY OTHERS

DI

DO

2. DISCHARGE AIR MAY BE HOT AND HUMID, PROTECT

DI
HOA

KQI

JS

HS

08/04/01

REVISED AS NOTED

07/09/13

ISSUED FOR APPROVAL

G.V.K.

M.D.

OPERATORS APPROPRIATELY.

YS

EXHAUST

I.B.

M.D.

3. TO BE INSTALLED AS CLOSE TO LIQUID RESERVOIR

YL

AS POSSIBLE.

DO
IAS

REV.

4. VACUUM LINES TO BE SLOPED DOWN TOWARDS TK-9200

DATE

APPROVAL

SUCH THAT LIQUID IS NOT ALLOWED TO COLLECT IN LINES.


WHERE LOW POINTS IN PIPING CANNOT BE AVOIDED, AN

M-

AUTOMATED DRAIN MUST BE INSTALLED. DISCUSS DESIGN

DESCRIPTION

ZONE

DSGN

APPD

DATE
(Y/M/D)

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

REQUIREMENTS WITH ZENON BEFORE INSTALLING.


5. FILTER TO BE INSTALLED IN HORIZONTAL ORIENTATION.
REFER TO VACUUM PUMP VENDOR DATA.

TYP. PNEUMATIC ACTUATED


VALVE CONTROL DETAIL

TYP. BLOWER CONTROL DETAIL

TYP. SOLENOID VALVE


CONTROL DETAIL

6. VACUUM PUMP MUST BE MOUNTED ON A STEEL FRAME FOR

CUSTOMER:

CADD FILE:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


VACUUM PUMPS & ASSOC. EQUIPMENT

ANCHOR BOLT ACCESS.


500408D009.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-009
2

SHEET

REV.

1 OF 1

12

11

10

SODIUM HYPOCHLORITE
SOLUTION FOR
RECOVERY CLEANS
1", SCH.80, CPVC

500408-D-011,SHT.1

FROM P-6600

SODIUM HYPOCHLORITE
SOLUTION FOR
MAINTENANCE CLEANS
", SCH.80, CPVC
500408-D-011,SHT.1

FROM P-5100
HIS

HH

YL

9700A

9700A

FI

FL

9720

9720

H
L
LL

HV-6696

HV-5196

HH

YA

YS

SC

SMY

HA

9700A

9700A

9700A

9700A

9700A

FY

FA

9720

9720

BPV-6694

H
L

BPV-5194

DI

DO

AO

FOR CLEANS

DI

", SCH.80, CPVC

AI

9700A

PI

CV-5198

FIT

JS

SC

HS

YL

9700A

9700A

9700A

9700A

M-9700A

CV-6598

FV-5160

FE
9720

HV-5198

HV-9740A
1/2"

4"

HV-6598

6", SCH.80, CPVC

6"

1/2"

FROM P-6500

0 TO 1000 GPM
HV-6698

9740A

HV-9741A

HV-6596

BPV-6594

RANGE:

9720

PI

9741A

CIP / DRAIN

500408-D-011,SHT.1

CV-6698

HOA
KQI

CITRIC
ACID SOLUTION

LL

6", SCH.80, CPVC


500408-D-003

CV-9785A

HV-9780A

HV-9781A

FV-9765

MAG
SEE NOTE 3

HV-9786A

HV-9787A

P-9700A

(MULTIPLE

NOTE 6
2
S

TO/FROM TK-3400

LINES)

", SCH.80, CPVC

FV-9732
1/2"

HIS

YL

9700B

9700B

YA

YS

HV-9732

HV-9734

HCV-9732

HCV-9734

9700B

SC

9700B

9700B

SMY
9700B

HA
NOTE 5

9700B

NOTE 4

AE
DI

DO

AO

DI

CHLORINE
ANALYZER

HOA
KQI

9700B

PI

JS
9700B

SC
9700B

YL

HS
9700B

9700B

AE
2

RESIDUAL

RANGE:
PI

TO

9740B

9734

pH

9732

Cl

AIT

AIT

9734

9732

AI

AI

M-9700B

HV-9740B
1/2"

4"

0 TO 14

HH

9741B

HV-9741B

FV-9762

RANGE:

ppm
HH

AY

AA

AY

AA

9734

9734

9732

9732

LL

SODIUM BISULPHITE
FOR NEUTRALIZATION
", SCH.80, CPVC

LL

500408-D-011,SHT.2

6"

1/2"

HV-5398 CV-5398 BPV-5394HV-5396


HV-9780B

AL

AI

HV-9781B
HV-9786B

HV-9787B

P-9700B

9734

9734

HH

AI

H
L

9732

AL
9732

LL

CIP/RECIRC./NEUTRALIZATION PUMPS

HH
H
L

LL

1 DUTY + 1 STANDBY

FROM P-5300

NOTE 6

CV-9785B

SODIUM HYDROXIDE
FOR NEUTRALIZATION
1", SCH.80, CPVC
500408-D-011,SHT.2

PANEL

306 GPM @ 22.5 FT

FV-9760

FROM P-5500

HV-5598 CV-5598 BPV-5594 HV-5596

5 HP @ 1180 RPM
480 V / 3 PH / 60 Hz

6", SCH.80, CPVC

D
PERMEATE

HH
6", SCH.10, 304L SS

TI

TL

9730

9730

500408-D-013

FV-9771

FROM COMMON

FV-9770A

HIS
9709

H
L
LL

6"

PERMEATE HEADER

YL
9709

HA

YS

YA

9709

9709

9709

VENT

HH
2

TY

TA

9730

9730

RANGE:
TO

^F

H
L

SEE NOTE 2

DI

LL

DO

FV-9745

DI

CV-9745

HOA

AI
POTABLE WATER

HH

2", SCH.10, 304L SS

LL

H
L
FROM PLANT SERVICE

HV-9790

LL

9726

LI
9726

JS

9709

9709

9709

TIT

TE

9730

9730

RANGE:
TO

HH
H
LL

HS

TK-9700

YLH

CIP TANK

WATER SOURCE

YL

LA

LY

9726

9726

AI

LE

9726

9726

TSH

HK

9709

9709

PE CONSTRUCTION

HV-9726

LIT

9709

2000 USGAL

IN

CT-2000

CV-9798
8"

TEMP.

HX-9700
2

6", SCH.80, CPVC

8", SCH.10, 304L SS

ELECTRIC HEATER
37 KW

NEUTRALIZED
CHEMICAL WASTE

HV-9795
FV-9775

HIS

HV-9799

TO RESIDUALS
HOLDING BASINS

HIS
NOTES:

YS

1. ALL DOTTED LINES/EQUIPMENT

08/04/01

REVISED AS NOTED

X.C.

M.D.

08/03/11

REVISED AS NOTED

I.B.

M.D.

07/09/13

ISSUED FOR APPROVAL

BY OTHERS
DO

YS

EXHAUST

2. PROVIDE AIR GAP.

I.B.

M.D.

3. 5 PIPE DIAMETERS UPSTREAM, 3 PIPE


REV.

DIAMETERS DOWNSTREAM, STRAIGHT PIPE

DO

DESCRIPTION

ZONE

DSGN

APPD

RUN RECOMMENDED FOR MAXIMUM ACCURACY.

IAS

APPROVAL

DATE
(Y/M/D)

4. ADD GOOSE NECK TO PREVENT DURING OF


CELLS PROBE.
5. DO NOT INSTALL PROBES UNTIL COMMISSIONING
2

TYP. PNEUMATIC ACTUATED


VALVE CONTROL DETAIL

DATE

6. INJECTION LINES TO BE LOCATED ON UNDERSIDE

TYP. SOLENOID VALVE


CONTROL DETAIL

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

BEGINS.

OF PIPES.

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


CLEANING SYSTEM TK-97

500408D010.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-010
2

SHEET

REV.

1 OF 1

12

11

10

SODIUM HYPOCHLORITE
FOR MAINTENANCE CLEANS

"
", SCH.80, CPVC

500408-D-010

NOTE 4
TO P-9700 DISCHARGE

SODIUM HYPOCHLORITE
FOR BIOGROWTH PREVENTION

500408-D-007

TO BACKPULSE TANK
TK-8800
PANEL LIMITS
HV-5180A

SODIUM HYPOCHLORITE

HV-5180B

"

FOR RECOVERY CLEANS


1", SCH.80, CPVC
500408-D-010

NOTE 4

", SCH.80, CPVC

1", SCH.80, CPVC

HV-6680A

TO P-9700 DISCHARGE

PANEL LIMITS
HV-6680B
2

YL

HIS

HIS

YL

YL

HIS

HIS

YL

5100A

5100A

5100B

5100B

6600A

6600A

6600B

6600B

YA

YS

YS

YA

YA

YS

YS

YA

5100A

5100A

5100B

5100B

6600A

6600A

6600B

6600B

DI

HV-5187A

DO

HV-5187B

DO

DI

DI

HV-6687A

DO

LI

HV-6687B

DO

DI
5100

YY

PSV-5183A

YY

YY

5100B

6600A

PSV-5183B

5100A

PSV-6683A

YY

PSV-6683B

6600B

P-5100A/B

LY
P-6600A/B

SODIUM HYPOCHLORITE PUMPS

COLUMN
FQMI-5148

HV-5181A

P-6600A

FQMI-5248

HV-6681A

HV-5181B
HV-5186A

P-5100B

HV-5186B

5100

FOR RECOVERY CLEANS

COLUMN

1", SCH.80, CPVC

P-5100A

SODIUM HYPOCHLORITE PUMPS

CALIBRATION
", SCH.80, CPVC

120 V/ 1 PH/ 60 HZ

", SCH.80, CPVC

CALIBRATION

1", SCH.80, CPVC

FOR MAINTENANCE CLEANS


0.13 GPM @ 58 PSIG MAX.

P-5200B

AI

1.27 GPM @ 58 PSIG MAX.


120 V/ 1 PH/ 60 HZ

LIT
5100
RANGE: TBD
LE
5100

CHEMICAL FILL LINE


1"

HV-6681B
HV-6686A

HV-6686B

FROM CHEMICAL
TRANSFER PUMPS
( BY OTHERS )

CITRIC ACID

LT-5100

1"

TK-5100
SODIUM HYPOCHLORITE
(SEE NOTE 2)
2

FOR RECOVERY CLEANS

"
", SCH.80, CPVC

500408-D-010

NOTE 4
HV-6580A

HV-6580B

YL

HIS

HIS

YL

6500A

6500A

6500B

6500B

YA

YS

YS

YA

6500A

6500A

6500B

6500B

DI

HV-6587A

DO
YY

HV-6587B

PSV-6583A

DO

DI

YY

PSV-6583B

6500A

TO P-9700 DISCHARGE

PANEL LIMITS

", SCH.80, CPVC

6500B

", SCH.80, CPVC

", SCH.80, CPVC

CALIBRATION
P-6500A

COLUMN
FQMI-6548

HV-6581A

CITRIC ACID PUMPS


FOR RECOVERY CLEANS
0.1 GPM @ 58 PSIG MAX.
120 V/ 1 PH/ 60 HZ
(SEE NOTE 4)

HV-6581B
HV-6586A

HIS

P-6500A/B
P-6500B

HV-6586B

08/04/01

REVISEE AS NOTED

G.V.K.

M.D.

08/03/11

REVISEE AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

NOTES:
I.B.

M.D.

1. ALL DOTTED LINES/EQUIPMENT


YS

REV.

BY OTHERS

DATE

APPROVAL

2. VENT ALL CHEMICAL TANKS APPROPRIATELY

DESCRIPTION

ZONE

DSGN

APPD

DATE
(Y/M/D)

DO
3. CHEMICAL PUMP SYSTEM WIRED TO LOCAL

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

JUNCTION BOX

4. TEMPORARY GAUGE CONNECTIONS FOR COMMISSSING


2

TYP. SOLENOID VALVE


CONTROL DETAIL

ONLY

TK-6500
CITRIC ACID TOTE

CADD FILE:

(BY OTHERS)

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


CLEANING CHEMICALS

500408D11 1.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.

(SEE NOTE 2)

IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-011
2

SHEET

REV.

1 OF 2

12

11

10

H
SODIUM BISULFITE
"
", SCH.80, CPVC
500408-D-010

TO P-9700 DISCHARGE
HV-5380A

HV-5380B

PANEL LIMITS

", SCH.80, CPVC

YL

HIS

5300A

5300A

YA

YS

5300A

5300A

DI

HV-5387A

HV-5387B

HIS

YL

5300B

5300B

YS

YA

5300B

5300B

DO

DO
PSV-5383A

DI
YY

PSV-5383B

YY

5300B

5300A

P-5300A/B

", SCH.80, CPVC

", SCH.80, CPVC

CALIBRATION
P-5300A

COLUMN
FQMI-5348

SODIUM BISULFITE PUMPS

P-5300B

FOR NEUTRALIZATION
0.010-0.102 GPM @ 58 PSIG MAX.
120 V/ 1 PH/ 60 HZ
(SEE NOTE 4)

F
HV-5381A

HV-5381B
HV-5386A

HV-5386B

E
2

TK-5300

SODIUM BISULFITE TOTE(BY OTHERS)


(SEE NOTE 2)

SODIUM HYDROXIDE
"
", SCH.80, CPVC
500408-D-010

TO P-9700 DISCHARGE
HV-5580A

HV-5580B

PANEL LIMITS

", SCH.80, CPVC

YL

HIS

5500A

5500A

HIS

YL

5500B

5500B

YS

YA

LI

YA

YS

6400A

5500A

5500

DI

5500B
HV-5587A

HV-5587B

DO

5500B
DI

DO
PSV-5583A

YY

PSV-5583B

YY

5500B

5500A

LY
5500

P-5500A/B

LIT
5500
RANGE: TBD

LE
5500

SODIUM HYDROXIDE PUMPS

", SCH.80, CPVC

P-5500A

", SCH.80, CPVC

CALIBRATION
AI

COLUMN
FQMI-5548

P-5500B

FOR NEUTRALIZATION
0.005-0.235 GPM @ 58 PSIG MAX.
120 V/ 1 PH/ 60 HZ
(SEE NOTE 4)

HV-5581A

HV-5581B
HV-5586A

HV-5386B

CHEMICAL FILL LINE


1"
2

LT-5100
FROM CHEMICAL
TRANSFER PUMPS
(BY OTHERS)

HIS

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

NOTES:

TK-5500

YS

I.B.

M.D.

1. ALL DOTTED LINES/EQUIPMENT

REV.

BY OTHERS

DATE

DESCRIPTION

ZONE

DSGN

APPD

SODIUM HYDROXIDE
APPROVAL

2. VENT ALL CHEMICAL TANKS APPROPRIATELY.

(SEE NOTE 2)

DATE
(Y/M/D)

DO
3. BACK PRESSURE VALVE WILL BE SHIPPED LOOSE

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

FOR INSTALLATION CLOSE TO INJECTION POINT.

4. CHEMICAL PUMP SYSTEM WIRED TO LOCAL


JUNCTION BOX.

TYP. SOLENOID VALVE


CONTROL DETAIL

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


NEUTRALIZATION CHEMICALS

500408D11 2.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-011
2

SHEET

REV.

2 OF 2

12

11

10

PLL
9108

PSV-9182A

G
YL
AC-9100A

PAL

9100A
9108
F-9100A
DI

M-9182A
YA

PSL

YS

9100A

DPI

PSL

9141

9108

9100A

9100A

DI

S.P.= 110 PSIG


DECREASING

DI

S.P.= 70 PSIG
DECREASING

TK-9100A
COMPRESSED AIR
"

RECEIVER TANK

"

"

INSTRUMENT AIR

1" 304L S.S. TUBING

"

120USGAL
HV-9181A

HV-9180A

(SEE NOTE 6)

LOCAL

HV-9182A

HV-9183

HV-9184

PRV-9182

3/4"

1/2"

HOA
KQI

HS

JS

YL

INTEGRAL

9100A 9100A

9100A 9100A
HOA
KQI

HS

JS

MULTIPLE LINES

REGULATOR

AUTO-DRAIN
F-9100

(SEE NOTE 6)

PRIMARY COALESCING

(1 PER TRAIN)

S.P.= 80 PSIG

TO DRYER

(SEE NOTE 2)

FILTER W/ INTEGRAL

YL

AUTO-DRAIN
9100B 9100B

9100B 9100B

1 u
m
ELECTRICAL
AUTO-DRAIN

PI

120 V/ 1 PH/ 60 HZ

1" 304L S.S. TUBING

DI

DI

YA

YS

9100B

9100B

E
YL
9100B

1" 304L S.S. TUBING

9140A

(SEE NOTE 5)

1" 304L S.S. TUBING

HV-9185
(SEE NOTE 3)
PSV-9182A

AC-9100B

F-9100B
M-9182B
PSL

S.P.= 90 PSIG

PI

DPI

DECREASING

9541

9100B
9542

HV-9541
1/2"

TK-9100B
COMPRESSED AIR

"

"

"

MIT AIR

"
500408-D-003

RECEIVER TANK
HV-9180B
3/4"

120USGAL
(SEE NOTE 6)

HV-9181B

HV-9182B

HV-9582

HV-9583

PRV-9586
S.P.= 10 PSIG

PSV-9564

HV-9580

TO MEMBRANES

CV-9580
HV-9598
MULTIPLE LINES
1/2"
(1 PER TRAIN)

S.P.= 11 PSIG

AUTO-DRAIN
2

INTEGRAL

F-9500

TO DRYER
(SEE NOTE 6)
DR-9182 A/B
REFRIGERATED AIR DRYER

ACTIVATED CARBON

FILTER W/ INTEGRAL

FILTER W/ INTEGRAL

AUTO-DRAIN

MANUAL DRAIN

0.01 um

MAX. 35 CFM @ 100 PSIG

DRAIN
SEE NOTE 7

0.01 um

1/3 HP

ELECTRICAL

ACF-9500

SECONDARY COALESCING

AUTO-DRAIN

120 V / 1 PH / 60 Hz

PI

120 V/ 1 PH/ 60 HZ
9140B

(SEE NOTE 5)

AC-9100A/B
AIR COMPRESSORS
1 DUTY + 1 STANDBY
7.5 HP, 1034 RPM
22.6 ACFM @ 175 PSIG MAX.
480 V/ 3 PH/ 60HZ
(SEE NOTE 4,6,8)

NOTES:
1. ALL DOTTED LINES/EQUIPMENT
BY OTHERS

08/04/01

REVISED AS NOTED

G.V.K.

M.D.

08/03/11

REVISED AS NOTED

G.C.

M.D.

07/09/13

ISSUED FOR APPROVAL

2. AT LEAST 1 ISOLATION VALVE PER


TRAIN (BY OTHERS).
3. HANDLE FOR BYPASS VALVE TO BE REMOVED

I.B.

M.D.

OR VALVE LOCKED IN CLOSED POSITION.


REV.

DATE

DESCRIPTION

ZONE

DSGN

APPD

4. FOOD GRADE OIL TO BE USED.


APPROVAL

DATE
(Y/M/D)

5. AUTO-DRAIN PLUGS INTO LOCAL OUTLET.


WALL GFCI PLUG REQUIRED BY OTHERS.
6. NOT CONTROLLED BY PLC.

DRWN: I.B.

07/04/26

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

7. DRAIN VALVES TO BE LOCATED AT ANY LOW


POINTS IN PIPING WHERE MOISTURE MAY
ACCUMULATE. EXTRA VALVES BY OTHERS.
8. LOCAL CONTROL PANEL INCLUDED WITH

CADD FILE:

COMPRESSOR.

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


AIR SYSTEM FOR PDT EQUIP. & VALVES

500408D012.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-012
2

SHEET

REV.

1 OF 1

12

11

10

TI
7530

TY
7530

AI

TIT

RANGE: 32 TO 120^F

7530
TE
7530
PERMEATE
10", SCH.10, 316L SS

"

30", SCH.10, 316L SS

500408-D-005
2

FROM PERMEATE PUMPS

BYOTHERS

VACUUM BREAKER
(SEE NOTE 2)

MULTIPLE LINES

FV-7537
1/2"

PERMEATE
6", SCH.10, 304L SS
500408-D-007

TO TK-8800

HH

PERMEATE

LI

LL

7526

7526

H
L
LL

6", SCH.10, 304L SS


500408-D-010

HH

TO TK-9700
LY

LA

7526

7526

H
L
LL

SEAL WEIR
AI

RANGE:
LIT
PERMEATE
10", SCH.10, 304L SS

7526

TO

IN

TBD

500408-D-001,SHT.2

LE
BYOTHERS
7526

COMMON PERMEATE
SAMPLE
500408-D-015

TK-7500
CLEARWELL

HIS

B
1

08/04/01

REVISED AS NOTED

07/09/13

ISSUED FOR APPROVAL

X.C.

M.D.

NOTE:
YS

I.B.

M.D.

1. ALL DOTTED LINES/EQUIPMENT


REV.

BY OTHERS
DO

DATE

APPROVAL

2. VACUUM BREAKER TO BE INSTALLED

DESCRIPTION

ZONE

DSGN

APPD

DATE
(Y/M/D)

AT HIGH POINT IN PIPING.

TYP. SOLENOID VALVE


CONTROL DETAIL

DRWN: A.P.L.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


PERMEATE STORAGE TANK

500408D013.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-013
2

SHEET

REV.

1 OF 1

12

11

10

PERMEATE SAMPLE
",P.E., TUBING
500408-D-005

(PER TRAIN)
PANEL

S
(SEE NOTE 2)

HV-3537-1

AE
RANGE:

HH

3537-1

0 - 1,000 mNTU

TURB

HH

AI1

A1

3536-1

3536-1

AJI

AJI

AJIT

3536-1

3536-1

3536-1

AL1

VENT

HH
H

3536-1

F
F-3536-1

AA
PART
3536-1

AE

AIT

FV-3536A-1

HCV-3536A-1

3536-1

3537-1
TK-3536-1
AI

DEGASSING

HH
AY

AA

PARTICLE

"

COUNTER

LL

3537-1 3537-1

(NOTE 2)

CYLINDER

HH
AI

AL

HV-3536C-1

1 -3536B-1

1/2"

3537-1 3537-1 L
LL

FE
3536B-1
HCV-3536B-1

F
SCREENED CLARIFIED
SAMPLE
",P.E., TUBING
500408-D-001,SHT.1

TO DRAIN
PANEL

HV-7637

AE
RANGE:

7637
TURB

0 - 1,000 mNTU

AIT
7637
AI
HH
AY

AA

7637

7637

AI

AL

7637

7637

H
L
LL
TO DRAIN
HH

H
L

LL

COMMON
PERMEATE SAMPLE
",P.E., TUBING
500408-D-013

PANEL

HV-7537

AE
RANGE:

7537
TURB

0 - 1,000 mNTU

AIT
7537
AI
HH
AY

AA

7537

7537

H
L
LL

HIS

TO DRAIN

HH
AI

AL

7537

7537

08/04/01

REVISED AS NOTED

07/09/13

ISSUED FOR APPROVAL

G.V.K.

M.D.

L
LL

I.B.

M.D.

YS
2
REV.

NOTES:

DO

APPROVAL

1. ALL DOTTED LINES/EQUIPMENT

DATE

BY OTHERS
2. DRAWING TYPICAL FOR TRAINS 1 TO 6.

TYP. SOLENOID VALVE


CONTROL DETAIL

DESCRIPTION

DSGN

APPD

DATE
(Y/M/D)

DRWN: I.B.

07/04/27

DSGN: K.S.

07/04/23

CHKD: N.K.

07/09/12

APPD: M.D.

07/09/12

CADD FILE:

ZONE

CUSTOMER:

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

PIPING & INSTRUMENTATION DIAGRAM


PARTICLE COUNTER & TURBIDIMETER

500408D015.DGN

THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC.


IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE

SCALE:

SIZE:

DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF

1:1

THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

D(24x36)

12

11

10

DRAWING NO.

500408-D-015
2

SHEET

REV.

1 OF 1