EPS-1000A

Electronic Phase Shifter

EPS-1000A
Electronic Phase Shifter

Single-phase input

Selectable voltage output

Graphic display screen

Automatic fault testing

Stores 60 test files

Field portable

DESCRIPTION
The EPS-1000A Electronic Phase Shifter is a fieldportable, self-contained, third-generation test set that
graphically displays the voltage configuration. It requires a
single-phase voltage input and provides a selectable
single-phase, phase-to-phase or three-phase voltage source
output for testing complex protective relays.
Model EPS-1000A graphically displays all selected voltage
and phase angle settings. This feature provides the unique
capability for the operator to visualize the voltage source
configuration while testing. The graphic screen displays
these voltages and phase angle settings along with an
extensive range of capabilities for modifying specific
testing applications.
APPLICATIONS
Model EPS-1000A is a compatible test set for testing threephase protective relays with SR-90, SR-76 and SR-51 test
sets. When used with a Multi-Amp relay test set, Model
EPS-1000A allows testing of a variety of complex relays.
The protective relays and their respective IEEE device
numbers are listed in the preceding table.
FEATURES AND BENEFITS
Graphically displays voltage and phase angles to visually
monitor the values for testing protective relays.

Single-phase; three-phase open delta; three-phase Tconnect; three-phase wye; and three-phase delta output
of both voltages and phase angles for testing virtually all
protective relays.

Relay types tested with


Model EPS-1000A and Model SR-90
Relay Types

IEEE
Device
Number

Impedance

21

Synchronizing

25

Directional Power

32

Loss-Of-Excitation or Field

40

Negative Sequence Undervoltage

47

Directional Overcurrent

67

Output voltages and phase angles are independently or


simultaneously selectable and fully adjustable in
performing three-phase or phase-to-phase tests.

Voltage phase angles are adjustable from 0 to 360 to


provide multiple fault testing parameters and calibration
settings.

Programmable delayed switching from Normal to Fault


to Post-Fault conditions automatically simulates a
dynamic test.

Saves up to 60 individual test files for identifying each


protective relay test using 19 ASCII characters.

Option screen allows operator full, customized use of


Model EPS-1000A for testing complex protective relays.
Unit offers easy setup of individual test parameters.

Compatible with five languages: English, Spanish,


German, Portuguese, French and Japanese.

Recessed front panel eliminates the need for a front


panel cover.

EPS-1000A
Electronic Phase Shifter

Soft-sided carrying case provides for easy carrying and


superior protection of the test set.

Modular design permits replacement of individual


modules and NIST calibration.

SPECIFICATIONS
Input Voltage
85 to 265 Vac
Reference Input
Current: 0.5 to 5 A
Voltage: 10 to 30 V

Model EPS-1000A displays all selected voltage


and phase angle settings.

Output Frequency
50/60 Hz or sync to line 2 Hz

Internal Reference
Phase lock to crystal oscillator

Amplitude Regulation
Accuracy: Maximum 1%, typical 0.5%
Harmonic Distortion: <1%

External Reference Indicator


Indicates phase lock to external source above 0.25 A or 1 V
Voltage Outputs
0 to 120 V at 60 VA
0 to 240 V at 60 VA
Choice of individually ganged outputs:
A-B, B-C, C-A, or A-B-C

Phase Variation
Accuracy: 2
Operating Temperature Range
32 to 113 F (0 to 45 C)

Overload Protection
Input: Fuse-protected
Power Supply: Overcurrent, under-voltage/overvoltage, thermal
Amplifiers: Current-limiting, thermal, fused

Storage Temperature
-20 to +158 F (-20 to +70) C
Dimensions
Model EPS-1000A
16.25 H x 24.5 W x 9.0 D in.
(413 H x 622 W x 229 D mm)

Phase Adjustment
Applicable for each phase to be set from 0 to 360
Allows operator to set positivesequence, negative-sequence and
zero-sequence fault conditions

Model EPS-1000A with carrying case


7.25 H x 21.25 W x 13.75 D in.
(184 H x 540 W x 349 D mm)

Test Mode Selection


Normal, Fault, Post-Fault
Test mode selection has a programmable delay from 0 to 999.9
cycles before initiation of test.

Weight
EPS-1000A
39 lb (17.7 kg)
EPS-1000A with carrying case
46 lb (21 kg)

Fault Output Adjustment


Line-to-Neutral: Single-phase, open delta, T-connect,
three-phase wye
Line-to-Line: Three-phase delta, phase-to-phase
Timer Contacts
Isolated contacts are selectable for normally open or normally
closed. Timer contacts initiate when fault is applied.

Graphic display screen

ORDERING INFORMATION
Item (Qty)

Cat. No.

Model EPS-1000A

EPS1000A

Item (Qty)

Cat. No.

Carrying case [1]

15493

Fuses
Included Accessories

10 A [5]

11333

Kit includes line cord, test leads, instruction


manual carrying case and fuses [1 set]

5 A [5]

11335

8 A [5]

962

0.0625 A [5]

987

15494

Test leads [5 pr]

1282

Line cord [1]

6828

UK
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
F +44 (0) 1304 207342

UNITED STATES
4271 Bronze Way
Dallas TX75237-188 USA
T 800 723 2861 (USA only)
T +1 214 330 3203
F +1 214 337 3038

Instruction manual [1]

OTHER TECHNICAL SALES OFFICES


Valley Forge USA, Toronto CANADA,
Mumbai INDIA, Trappes FRANCE,
Sydney AUSTRALIA, Madrid SPAIN
and the Kingdom of BAHRAIN.

15690

Registered to ISO 9001:2000 Reg no. Q 09290


Registered to ISO 14001 Reg no. EMS 61597

EPS_1000A_DS_en_V10
www.megger.com
Megger is a registered trademark

You might also like