Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

REVISION

RdC

150

600

5165

800

BASE PLATES SUPPLIED AND


GROUTED BY MASSKOT

5645

4845

5605

800

5105

4365

600

COLAS LUSAKA

260

200

NOTES:

100

100

USE POLYSTYRENE
TO CREATE POCKET
( NOT TIMBER )

DETAIL 'X'

SCALE: 5:1

TYP 10 POSITIONS

DURING INSTALLATION, TRUCK ACCESS ON ONE SIDE

FOR RAMP DETAILS SEE RAMP DETAIL DRAWING

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH


NOTES FOR WEIGHBRIDGE FOUNDATION PLAN

(LENGTH) OF THE FOUNDATION IS A REQUIREMENT.

3.

THIS DRAWING IN NO WAY CONSTITUTES A STRUCTURAL

DWG. No: WB 2965-1

REV: 01

FOUNDATION DETAILS
22 x 3,2m WEIGHBRIDGE
SINGLE DECK 10 SUPPORT

TITLE:

ALL BASE PLATE BEARING SURFACES TO BE STEEL FLOAT


FINISHED.

THE PURCHASER IS RESPONSIBLE FOR SUCH DESIGN.

DRAWING OF A WEIGHBRIDGE FOUNDATION.

4.

6.

5.

1.

3800

22040

22365

4805

CUSTOMER

CHKD:

22365

800

BASE PLATES SUPPLIED AND


GROUTED BY MASSKOT

SCALE: 1:1

APPR:

C:\DRAWINGS\STANDARD SCALES\WEIGHBRIDGES\FOS\22x3,2\0615

DATE: 06/09/2013

DRAWN: R. da COSTA
FILE No.

REF. No. MS 130241

+/_1,0mm
+/_ 1,5 mm
+/_ 2, 0mm

TOL.
+/_ 0,5 mm

GENERAL TOLERANCES
FABRICATION
0-200 mm
201-500 mm
501-1000 mm
1001AND ABOVE

M3E - 3200

MASSKOT
21 ORION STREET PO BOX 2572
PRIMROSE 1416
TEL: (011) 873-5555 FAX: (011) 873-1934

FILE REF.

TYP 6 POSITIONS
SCALE: 4:1

DETAIL 'Z'

400

SECTION A-A

NATURAL FALL

SCALE TYPE

75

4425

400
MESH TO BE USED:
'395' ( 200 x 200 x 8 DIA )

GROUND
LEVEL

MASS MEASURING SYSTEMS (PTY) LTD.

150

CHANNEL 152 x 76
260

600

DETAIL 'Y'
TYP BOTH ENDS
SCALE: 4:1

380
300

330

This drawing is the property of Mass Measuring Systems (Pty) Ltd.


It is subject to return on demand and may not be passed on to any
third party, or used directly or indirectly for any other purpose
than the manufacture or construction of equipment or in the design
and installation of plant. This is on specific / written instruction
from M.M.S. only.

DO NOT SCALE

100 SLAB

260

300

ISSUED FOR CONSTRUCTION

330

200

LUGS TO BE SPACED AT 750 CRS


& WELDED TO THE END COPINGS.
ALL LUGS TO BE WELDED TO THE
FOUNDATION MESH AS PART OF
THE LIGHTNING PROTECTION. ALL
MESH SHEETS TO BE WELDED
TOGETHER THROUGHOUT THE
FOUNDATION.

06/09/13

380

1695
1695

MK BY DATE DESCRIPTION

01