Standarisasi: Perawatan Generator AE (Cleaning) MT - Fery XVI

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

STANDARISASI

PT.LSBL

No Dokumen
Tanggal
Revisi
Halaman

Perawatan Generator AE (Cleaning) MT.Fery XVI

No

PIC

Aktivitas

Tools

Chief
Engginer

Buka connection kabel 3


phase + netral di terminal
block generator dan kabel
AVR

Chief
Engginer

Lakukan pengukuran
tahanan isolasi (megger
test)

Chief
Engginer

Buka Exiter,rotor,dan stator.

Kunci pas, obeng,


tackle, sling belt,
tali.

Chief
Engginer

Bersihkan eksiter,rotor,dan
stator menggunakan contact
cleaner dan tunggu sampai
kering.

Kuas bersih, kain


majun, sikat bulu,
contact cleaner.

Kunci sok, Kunci


pas, Obeng set

Megger tester,
Multitester

22 September 2015
0
Nurfuadi

Hendy C

Di Buat

Di Setujui

Remarks

STANDARISASI
PT.LSBL

No Dokumen
Tanggal
Revisi
Halaman

Perawatan Generator AE (Cleaning) MT.Fery XVI

Chief
Engginer

Setelah semua dibersihkan,


Semprotkan varnish secara
merata pada lilitan
exiter,rotor,dan stator.
Tunggu sampai kering.

Varnish red atau


Sirlak

Chief
Engginer

Pasang kembali Exiter,rotor


dan stator.

Tackle, sling belt,


tali, kunci pas.

Chief
engginer

Lakukan pengukuran lagi


(tahanan isolasinya)Atau
(megger test)

Written by : TECHNICAL

22 September 2015
0
Nurfuadi

Hendy C

Di Buat

Di Setujui

Megger tester

Approved by :
VP/DPA

Retention Period : 1
year

You might also like