Professional Documents
Culture Documents
WIT-PE 500 Design Manual RB
WIT-PE 500 Design Manual RB
Approved for:
Concrete C20/25 to C50/60, cracked
Suitable for:
Concrete C12/15, Natural stone with dense structure
385 ml
Artnr.: 0903480001
1400 ml
Artnr.: 0903480002
8 - 40
Benefits:
Europ
Benefits:
The prolonged gelling/working time allows
convenient adjustment at higher temperature and
with large embedment depth.
Its many approvals guarantees optimized load
capacities for threaded rods and rebar.
Its specially developed chemical composition allows
a reliable installation in underwater conditions and
when filled in diamond cored drill holes.
The low shrinkage of the mortar broadens the
application spectrum in addition for big diameter
fastener elements.
Applications
Xx1
Description
Authority/
Laboratory
Guideline
for Assessment
No./date of issue
DIBt, Berlin
DIBt, Berlin
ICC
MPA Braunschweig
eurofins
eurofins
NSF International
ETAG 001-T5
TR 023 / EC 2
AC 308
TR 020
Leed 2009 EQ c4.1
DEVL 1101903D, DEVL 1104875A
NSF/ANSI Standard61
ETA-09/0040 / 2013-06-14
ETA-07/0313 / 2013-05-30
ESR-2538 / 2012-05-01
3302/252/08-N13/2009-01-07
G15982K / 2012-10-30
2013-03-13
2013-11-13
WIT-PE 500 R
Characteristic resistance
Anchor type: WIT-PE 500 R
8 10 12 14 16
Rebar size
Effective anchorage depth
hef,typ
[mm]
80
90
110
125
125
20 25 28 32 40
170
210
270
300
360
Non-cracked concrete
Tensile
C20/25
NRk
[kN]
28.1
39.6
53.9
70.6
C50/60
NRk
[kN]
31.0
43.5
59.3
77.6
C20/25
VRk
[kN]
13.8
21.6
31.1
42.3
55.3
Tensile
C20/25
NRk
[kN]
31.1
38.5
40.8
64.1
C50/60
NRk
[kN]
34.2
42.3
44.9
70.5
Shear
C20/25
VRk
[kN]
31.1
42.3
55.3
Shear
Cracked concrete
Design resistance
Anchor type: WIT-PE 500 R
8
Rebar size
Effective anchorage depth
10 12 14 16
20 25 28 32 40
hef,typ
[mm]
80
90
110
125
125
170
210
270
300
360
Non-cracked concrete
Tensile
Shear
C20/25
NRd
[kN]
15.6
22.0
29.9
39.2
39.2
53.3
C50/60
NRd
[kN]
17.2
24.2
32.9
43.1
43.1
58.6
C20/25
VRd
[kN]
9.2
14.4
20.7
28.2
36.9
57.6
Cracked concrete
Tensile
Shear
C20/25
NRd
[kN]
17.3
21.4
22.7
30.5
41.5
60.0
79.0
C50/60
NRd
[kN]
19.0
23.5
25.0
33.6
45.6
66.0
86.9
C20/25
VRd
[kN]
20.7
28.2
36.9
57.6
Xx2
WIT-PE 500 R
Rebar size
Effective anchorage depth
hef,typ
[mm]
80
Non-cracked concrete
10 12 14 16
90
110
20 25 28 32 40
125
125
170
210
270
300
Benefits:
Europ 28.0
15.7 21.4
28.0
38.1
52.3
76.2
89.3 117.3
98.2 129.1
Tensile
C20/25
Nrec
[kN]
11.2
C50/60
Nrec
[kN]
12.3
17.3
23.5
30.8
30.8
41.9
57.5
83.8
Shear
C20/25
Vrec
[kN]
6.6
10.3
14.8
20.2
26.3
41.1
64.3
Tensile
C20/25
Nrec
[kN]
12.3
15.3
16.2
21.8
29.6
42.8
56.4
C50/60
Nrec
[kN]
13.6
16.8
17.8
24.0
32.6
47.1
62.1
Shear
C20/25
Vrec
[kN]
14.8
20.2
26.3
41.1
64.3
80.6 105.3
Cracked concrete
1)
Xx3
360
Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.
Simplified version of the design method according ETAG 001, TR 029. Design resistance
according data given in ETA-09/0040, issue 2013-06-14:
Influence of concrete strength.
Influence of edge distance.
Influence of spacing.
Valid for a group of anchors. (The influencing factors must then be considered for each edge distance and spacing.
The calculated design loads are then on the save side. They will be lower than the exact values according
ETAG 001, Annex C. To avoid this, it is recommended to use the anchor design software of Wrth).
The design method is based on the following simplification: No different loads are acting on individual anchors
(no eccentricity).
Temperate range I (min. base material temperature -40C, max. long term/short term base material temperature:
+24C/40C).
Dry or wet conditions of drill hole, hammer drilling.
Installation temperature range +5C to +40C.
40 not part of ETA, data based on in-house testing according to guideline.
WIT-PE 500 R
Tension loading
The decisive design resistance in tension is the lowest value of the following failure modes:
Steel failure:
Combined Pull out and concrete cone failure:
Concrete cone failure:
Concrete splitting failure:
of a single anchor
BS4449:1997
DIN1045-1:2008:08/
DIN 488-1:2009:08 /
DIN EN 1992-1-1:
2011-01
Rebar
grade
Rebar
size
460A
NRd,s
460B
NRd,s
BST
500 S,
B500B
NRd,s
10
12
14
16
20
25
28
32
40
[kN]
17.4
27.1
39.0
53.1
69.4
[kN]
17.8
27.9
40.1
54.6
71.3
[kN]
19.7
30.9
44.4
60.5
79.0
Xx4
WIT-PE 500 R
of a single anchor
Benefits:
Europ16
14
10
12
20
25
28
32
40
[mm]
80
90
110
125
125
170
210
270
300
360
[kN]
15.6
22.0
29.9
39.7
41.9
61.0
82.9
120.0
158.0
172.3
17.3
21.4
22.7
30.5
41.5
60.0
79.0
Rebar size
hef,typ
of a single anchor
Non-cracked concrete
N0Rd,p
Cracked concrete
N0Rd,p
[kN]
fck,cyl
[N/mm2]
12
16
20
25
30
35
40
45
50
fck,cube
[N/mm2]
15
20
25
30
37
45
50
55
60
Influencing factor
fb,N
[-]
0.77
0.89
1.00
1.02
1.04
1.06
1.08
1.09
1.10
1)
2)
Xx5
10
12
14
16
20
25
28
32
40
hef,typ
[mm]
80
90
110
125
125
170
210
270
300
360
scr,p
[mm]
194
242
277
323
360
438
526
575
681
826
ccr,p
[mm]
97
121
139
162
180
219
263
287
341
413
Rebar size
WIT-PE 500 R
Number of
s/scr,p1)
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fsx,p, fsy,p
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fsx,p, fsy,p
0.40
0.43
0.47
0.50
0.53
0.57
0.60
0.63
0.67
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.93
0.97
1.00
fsx,p, fsy,p
0.33
0.36
0.40
0.44
0.48
0.51
0.55
0.59
0.63
0.66
0.70
0.74
0.78
0.81
0.85
0.89
0.93
0.96
1.00
fsx,p, fsy,p
0.28
0.32
0.36
0.40
0.44
0.48
0.52
0.56
0.60
0.64
0.68
0.72
0.76
0.80
0.84
0.88
0.92
0.96
1.00
fixing per
direction
1)
Choose always the lowest value of the spacing s, when there are different spacings in one row.
;
c/ccr,p
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fcx,1,p
0.73
0.75
0.76
0.78
0.79
0.81
0.82
0.84
0.85
0.87
0.88
0.90
0.91
0.93
0.94
0.96
0.97
0.99
1.00
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fcx,2,p
fcy,p
of a single anchor
Xx6
WIT-PE 500 R
of a single anchor
Rebar size
hef,typ
[mm]
80
90
110
125
N0Rd,c
125
170
210
73.2
52.3
[kN]
20.1
24.0
32.4
Benefits:
Europ 53.3
39.2 39.2
[kN]
14.3
17.1
23.1
28.0
Non-cracked concrete
28 32 40
270
300
360
Cracked concrete
N0Rd,c
28.0
38.1
76.2
89.3 117.3
1)
2)
fck,cyl
[N/mm2]
12
16
20
25
30
35
40
45
50
fck,cube
[N/mm2]
15
20
25
30
37
45
50
55
60
Influencing factor
fb,N
[-]
0.77
0.89
1.00
1.10
1.22
1.34
1.41
1.48
1.55
Xx7
Rebar size
10
12
14
16
20
25
28
32
40
hef,typ
[mm]
80
90
110
125
125
170
210
270
300
360
scr,N
[mm]
240
270
330
375
375
510
630
810
900
1080
ccr,N
[mm]
120
135
165
188
188
255
315
405
450
540
WIT-PE 500 R
Above characteristic spacing and edge distances are given for the typical effective anchorage depth. Calculating for
smaller depths is leading to conservative load capacities. For calculation with bigger depths use the following:
and
.
Number of
s/scr,N1)
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fsx, fsy
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fsx, fsy
0.40
0.43
0.47
0.50
0.53
0.57
0.60
0.63
0.67
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.93
0.97
1.00
fsx, fsy
0.33
0.36
0.40
0.44
0.48
0.51
0.55
0.59
0.63
0.66
0.70
0.74
0.78
0.81
0.85
0.89
0.93
0.96
1.00
fsx, fsy
0.28
0.32
0.36
0.40
0.44
0.48
0.52
0.56
0.60
0.64
0.68
0.72
0.76
0.80
0.84
0.88
0.92
0.96
1.00
fixing per
direction
1)
Choose always the lowest value of the spacing s, when there are different spacings in one row.
c/ccr,N
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fcx,1
0.73
0.75
0.76
0.78
0.79
0.81
0.82
0.84
0.85
0.87
0.88
0.90
0.91
0.93
0.94
0.96
0.97
0.99
1.00
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fcx,2
fcy
Xx8
WIT-PE 500 R
10
12
14
16
20
25
28
32
40
hef,typ
[mm]
80
90
110
125
125
170
210
270
300
360
scr,sp
[mm]
360
420
528
816
1008
1296
1440
1728
ccr,sp
[mm]
180
210
264
300
300
408
504
648
720
864
hmin
[mm]
110
120
134
153
157
210
258
324
364
440
Rebar size
Benefits:
600
600
Europ
Above characteristic spacing and edge distances are given for the typical effective anchorage depth. Calculating for
smaller depths is leading to conservative load capacities. For calculation with bigger depths use the following:
and
and
Number of
s/scr,sp1)
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fsx,sp, fsy,sp
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fsx,sp, fsy,sp
0.40
0.43
0.47
0.50
0.53
0.57
0.60
0.63
0.67
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.93
0.97
1.00
fsx,sp, fsy,sp
0.33
0.36
0.40
0.44
0.48
0.51
0.55
0.59
0.63
0.66
0.70
0.74
0.78
0.81
0.85
0.89
0.93
0.96
1.00
fsx,sp, fsy,sp
0.28
0.32
0.36
0.40
0.44
0.48
0.52
0.56
0.60
0.64
0.68
0.72
0.76
0.80
0.84
0.88
0.92
0.96
1.00
fixing per
direction
1)
Choose always the lowest value of the spacing s, when there are different spacings in one row.
c/ccr,sp
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.85
0.90
0.95
1.0
fcx,1, sp
0.73
0.75
0.76
0.78
0.79
0.81
0.82
0.84
0.85
0.87
0.88
0.90
0.91
0.93
0.94
0.96
0.97
0.99
1.00
0.55
0.58
0.60
0.63
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.83
0.85
0.88
0.90
0.93
0.95
0.98
1.00
fcx,2, sp
fcy, sp
Xx9
h/hmin
1.00
1.10
1.20
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
2.90
fh
1.00
1.07
1.13
1.19
1.25
1.31
1.37
1.42
1.48
1.53
1.59
1.64
1.69
1.74
1.79
1.84
1.89
1.94
1.99
2.00
WIT-PE 500 R
Shear loading
The decisive design resistance in shear is the lowest value of the following failure modes:
Steel failure:
Concrete pry-out failure:
Concrete edge failure:
of a single anchor
BS4449:1997
DIN1045-1:2008:08 /
DIN 488-1:2009:08 /
DIN EN 1992-1-1:
2011-01
Rebar
grade
Rebar
size
460A
VRd,s
460B
VRd,s
BST
500 S,
B500B
VRd,s
10
12
14
16
20
25
[kN]
8.1
12.6
18.2
24.8
32.4
50.6
79.0
[kN]
8.3
13.0
18.7
25.5
33.3
52.0
81.3
[kN]
9.2
14.4
20.7
28.2
36.9
57.6
90.0
28
32
40
of a single anchor
[mm]
[-]
10
12
14
16
20
25
28
32
40
80
90
110
125
125
170
210
270
300
360
Xx10
WIT-PE 500 R
Verification of concrete edge failure may be omitted for single fasteners and groups with an edge distance in all
directions
. For anchorages with more than one edge, the resistance for all edges shall be
calculated. The smallest value should be used in the verification.
Benefits:
Europ
Basic design concrete edge resistance
of a single anchor
Anchor type: WIT-PE 500 R
8
10
12
14
16
20
25
28
32
40
[kN]
5.2
7.5
10.1
13.1
16.4
24.3
36.3
42.3
50.5
68.0
[kN]
3.7
5.3
7.1
9.2
11.6
17.1
25.6
29.7
35.5
47.8
Rebar size
Non-cracked concrete
V0Rd,c
Cracked concrete
V0Rd,c
1)
2)
fck,cyl
[N/mm2]
12
16
20
25
30
35
40
45
50
fck,cube
[N/mm2]
15
20
25
30
37
45
50
55
60
Influencing factor
fb,V
[-]
0.77
0.89
1.00
1.10
1.22
1.34
1.41
1.48
1.55
10
11
12
0.87
0.91
0.94
0.97
1.00
1.02
1.05
1.07
1.08
Xx11
12
15
20
30
40
50
60
100
150
200
0.47
1.19
2.05
2.76
4.05
6.96
10.22
13.76
17.54
34.66
59.52
87.35
WIT-PE 500 R
1)
1)
f,V
10
20
30
40
50
60
70
80
90
1.00
1.01
1.05
1.11
1.20
1.34
1.51
1.72
1.92
2.00
For 90 the component of the shear load acting away from the edge may be neglected and the verification may
be done with component acting parallel to the edge only.
Influence of spacing
In groups loaded perpendicular to the edge only two adjacent anchors closest and parallel to the edge carry the load.
The smallest spacing should be used for the verification.
1)
s/c11)
0.50
0.60
0.70
0.80
0.90
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
2.80
3.00
fs,V
1.17
1.20
1.23
1.27
1.30
1.33
1.40
1.47
1.53
1.60
1.67
1.73
1.80
1.87
1.93
2.00
Choose always the lowest value of the spacing s, when there are different spacings in the row closest to the edge.
1)
c2/c11)
1.00
1.10
1.20
1.30
1.40
1.50
fc,V
0.75
0.80
0.85
0.90
0.95
1.00
h/c1
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.50
fh,V
0.26
0.37
0.45
0.52
0.58
0.63
0.68
0.73
0.77
0.82
0.86
0.89
0.93
0.97
1.00
Xx12
WIT-PE 500 R
Benefits:
Europ
Shear
Xx13
Temperature range
Base material
temperature
Temperature range I
-40 C to +40 C
+24 C
+40 C
Temperature range II
-40 C to +60 C
+43 C
+60 C
-40 C to +72 C
+43 C
+72 C
WIT-PE 500 R
Service temperature
Rebar size
10
12
14
16
20
25
28
32
40
Design bond strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III
Rd,ucr
[N/mm2]
7.8
7.8
7.2
7.2
6.7
5.7
5.2
5.2
5.2
3.8
[N/mm ]
4.7
4.7
4.4
4.4
4.2
3.3
3.3
3.1
3.1
2.1
Rd,ucr
[N/mm2]
4.2
4.2
4.2
3.9
3.9
3.1
2.9
2.9
2.9
1.9
Rd,ucr
[N/mm2]
6.7
6.2
5.2
4.8
4.5
4.0
3.6
3.3
2.9
[N/mm ]
4.0
4.0
3.8
3.8
3.6
3.3
2.9
2.6
2.4
Rd,ucr
[N/mm2]
3.6
3.6
3.6
3.3
3.3
2.9
2.6
2.4
2.1
Rd,ucr
[N/mm2]
7.3
5.6
5.6
5.6
5.3
5.0
[N/mm ]
4.7
3.6
3.6
3.3
3.3
3.1
Rd,ucr
[N/mm2]
4.0
3.3
3.3
3.1
2.8
2.8
Rd,ucr
[N/mm2]
6.0
5.6
5.6
5.3
5.3
4.7
[N/mm2]
3.7
3.6
3.6
3.3
3.3
3.1
Rd,ucr
[N/mm ]
3.3
3.3
3.1
3.1
2.8
2.8
10
12
14
16
20
25
28
32
Rd,ucr
Rd,ucr
Design bond strength according to ETA-11/0398 / dry and wet concrete / diamond drilling
Temperature range I
Temperature range II
Temperature range III
Rd,ucr
Rd,ucr
Rebar size
40
Design bond strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III
Rd,cr
[N/mm2]
4.2
3.9
3.6
2.9
2.6
2.6
2.6
[N/mm ]
2.5
2.2
2.2
1.7
1.7
1.7
1.7
Rd,cr
[N/mm2]
2.2
1.9
1.9
1.4
1.4
1.4
1.4
Rd,cr
[N/mm2]
3.6
3.1
2.9
2.4
2.1
1.9
1.9
[N/mm2]
2.1
1.9
1.9
1.7
1.7
1.7
1.4
Rd,cr
[N/mm ]
1.9
1.9
1.9
1.4
1.4
1.4
1.4
Rd,cr
Rd,cr
Xx14
WIT-PE 500 R
Rebar size
10
12
14
16
20
25
28
32
40
Reduction factor strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III
Benefits:
f.red
1.00
1.00
1.00
0.61
0.61
0.62
f.red
0.54
0.54
0.58
f.red
0.86
0.80
0.73
0.66
0.52
0.52
0.53
0.53
f.red
0.46
0.46
0.49
0.46
f.red
1.00
1.00
Europ
1.00
1.00
1.00
1.00
1.00
0.62
0.63
0.58
0.64
0.59
0.59
0.56
0.54
0.58
0.54
0.55
0.55
0.55
0.50
0.68
0.71
0.68
0.64
0.55
0.54
0.58
0.55
0.50
0.45
0.50
0.50
0.50
0.45
0.41
f.red
Reduction factor according to ETA-11/0398 / dry and wet concrete / diamond drilling
Temperature range I
Temperature range II
Temperature range III
f.red
1.20
1.00
1.00
1.05
1.23
1.17
0.76
0.65
0.65
0.63
0.78
0.71
f.red
0.65
0.60
0.60
0.58
0.65
0.65
f.red
0.98
1.00
1.00
1.00
1.23
1.10
0.60
0.65
0.65
0.63
0.78
0.71
f.red
0.55
0.60
0.55
0.58
0.65
0.65
10
12
14
16
20
25
28
32
f.red
f.red
Rebar size
Reduction factor according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III
f.red
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.60
0.57
0.62
0.58
0.64
0.64
0.64
f.red
0.53
0.50
0.54
0.50
0.55
0.55
0.55
f.red
0.86
0.80
0.79
0.83
0.82
0.73
0.73
0.51
0.49
0.53
0.58
0.64
0.64
0.55
f.red
0.46
0.49
0.53
0.50
0.55
0.55
0.55
f.red
Xx15
f.red
40
Rebar size
10
12
14
16
20
25
28
32
40
hef,min
[mm]
60
60
70
75
80
90
100
112
128
160
hef,max
[mm]
96
120
144
168
192
240
300
336
384
480
d0
[mm]
12
14
16
18
20
24
32
35
40
50
Drill depth
h0 / h1 [mm]
Min. thickness of
concrete member
hmin
[mm]
Minimum spacing
smin
[mm]
40
50
60
70
80
100
125
140
160
200
cmin
[mm]
40
50
60
70
80
100
125
140
160
200
WIT-PE 500 R
Anchor characteristics
= hef
= hef +30mm 100mm
= hef + 2d0
hmin
h0
d0
hef
Xx16
WIT-PE 500 R
460A
BS4449:
1997
460B
DIN1045-1:
2008:08 /
DIN 488-1:
2009:08 /
DIN EN 19921-1: 2011-01
Xx17
BST 500 S,
B500B
8 10 12 14 16 20
Rebar size
25
28 32 40
Stressed
cross
section
As
[mm]
50
Benefits:
79 113 154
Europ
201
314
Section
Modulus
[mm]
50
98
170
269
402
Yield
strength
fy
[N/mm2] 460
460
460
460
460
460
460
460
460
460
Tensile
strength
fu
[N/mm2] 483
483
483
483
483
483
483
483
483
483
Design
bending
moment
M0Rd,s
[Nm]
19
38
66
104
155
303
593
Yield
strength
fy
[N/mm2] 460
460
460
460
460
460
460
460
460
460
Tensile
strength
fu
[N/mm2] 497
497
497
497
497
497
497
497
497
497
Design
bending
moment
M0Rd,s
[Nm]
20
39
67
107
160
312
610
Yield
strength
fy
[N/mm2] 500
500
500
500
500
500
500
500
500
500
Tensile
strength
fu
[N/mm2] 550
550
550
550
550
550
550
550
550
550
Design
bending
moment
M0Rd,s
[Nm]
43
75
119
177
346
675
22
491
616
804 1257
Class
WIT-PE 500 R
400 to 600
1,15
<1,35
1,08
5,0
Bendability
7,5
Bend / Rebend test
6,0
4,5
Class
Nominal diameter
of the rebar (mm)
8 to 12
>12
0,040
0,056
45 min
45 h
90 h
30 min
10 h
20 h
20 min
6 h
12 h
40C
12 min
4 h
8h
Xx18
WIT-PE 500 R
d0
[mm]
Drill depth
h0 / h1
[mm]
Xx19
[ml]
10
12
12
14
16
0.80
0.96
1.11
14
16
20
25
28
32
40
18
20
24
32
35
40
50
2.21
2.70
4.30
5.64
8.77
Benefits:
Europ
1.27
1.45
= hef
or
Installation
Control
Blow out at least 2x from the back of the bore hole until
return air stream is free of noticeable dust.
If the back of the bore hole is not reached an extension
shall be used.
The hand-pump can be used for anchor sizes up to bore
hole diameter 20 mm. For bore holes larger than 20 mm
or deeper 240 mm, compressed air (min. 6 bar) must be
used.
WIT-PE 500 R
Installation instruction
Blow out at least 2x from the back of the bore hole until
return air stream is free of noticeable dust.
If the back of the bore hole is not reached an extension
shall be used.
The hand-pump can be used for anchor sizes up to bore
hole diameter 20 mm. For bore holes larger than 20 mm
or deeper 240 mm, compressed air (min. 6 bar) must be
used.
Prior to inserting the anchor rod into the filled bore hole,
the position of the embedment depth shall be marked on
the anchor rods.
Xx20
WIT-PE 500 R
Control
Benefits:
Europ
Discard initial adhesive. An initial amount of 10cm
adhesive has to be discarded.
Visual check if resin is evenly in colour.
For every working interruption longer than the
recommended working time as well as for new cartridges,
a new mixing nozzle shall be used.
(see table Working and cure times)
Inject the adhesive starting at the back of the hole, slowly
withdrawing the mixer with each trigger pull.
Fill holes approximately 2/3 full, or as required to ensure
that the annular gap between the anchor and the concrete
is completely filled with adhesive along the embedment
length.
For embedment larger than 190mm an extension nozzle
shall be used.
For overhead and horizontal installation in bore holes
larger than 20mm a injection adapter and extension
nozzle shall be used.
Xx21
d0
[mm]
Drill depth
h 0 / h1
[mm]
10
12
14
16
20
25
28
32
40
12
14
16
18
20
24
32
35
40
50
WIT-PE 500 R
Accessoires
= hef
Hammer Drills
H 36-MAS / H24-MLS (SDS-plus)
BMH 32-XE (SDS-Plus)
BMH 40-XES (SDS-Max)
BMH 45-XE (SDS-Max)
Drill Bits
LONGLIFE QUADRO-L (0648 xxx yyy)
LONGLIFE QUADRO-L (0647 0xx yyy)
QUADRO-S (0647 7xx yyy)
Brush
8
Thread size
10
12
14
16
20
25
28
32
40
41.5
52
Brush diameter
db
[mm]
14
16
18
20
22
26
34
37
Brush length
lb
[mm]
170
200
200
300
300
300
300
300
...010
...012
...014
...016
...020
...025
... 028
25
28
Brush
0905 489 ...
...008
on demand
Brush extension
Blow-out (manual)
Thread size
Blow-out pump (manual)
10
12
14
16
20
32
40
Xx22
WIT-PE 500 R
10
... 210
12
14
16
... 214
Thread adapter
20
... 217
28
32
40
32
40
... 227
0699 903 7
0699 903 13
Benefits:
Europ
Hose
25
Injecting
Thread size
10
12
14
16
20
Dispensing gun
0891 009
0891 017
0891 015
25
Mixer nozzle
Mixer extension 10
Mixer extension 16
Injection adapter (repulsion piston)
0903 488 ...
Xx23
28
...008
...010
...012
...014
...016
...020
...025
...028
Chemical Agent
Acetic acid
Laitance
Acetone
Ammonia, aqueous solution
Aniline
Beer
Chlorine
Benzol
Boric Acid, aqueous solution
Calcium carbonate, suspended in water
Calcium chloride, suspended in water
Calcium hydroxide, suspended in water
Carbon tetrachloride
Caustic soda solution
Citric acid
Diesel oil
Ethyl alcohol, aqueous solution
Formic acid
Formaldehyde, aqueous solution
Freon
Fuel Oil
Gasoline (premium grade)
Glycol (Ethylene glycol)
Hydrochloric acid (Muriatic Acid)
Hydrogen peroxide
Isopropyi alcohol
Lactic acid
Linseed oil
Lubricating oil
Magnesium chloride, aqueous solution
Methanol
Motor oil (SAE 20 W-50)
Nitric acid
Oleic acid
Perchloroethylene
Petroleum
Phenol, aqueous solution
Phosphoric acid
Phosphoric acid
Potash lye (Potassium hydroxide, 10% and 40% solution)
Potassium carbonate, aqueous solution
Potassium chlorite, aqueous solution
Potassium nitrate, aqueous solution
Sodium carbonate
Sodium Chloride, aqueous solution
Sodium phosphate, aqueous solution
Sodium silicate
Sulfuric acid
Tartaric acid
Tetrachloroethylene
Toluene
Trichloroethylene
Turpentine
Concentration
40
10
5
100
100
All
100
All
100
40
All
100
50
100
30
100
Conc.
30
100
All
100
100
All
100
100
10
100
100
100
8
85
10
All
All
All
All
All
All
All
30
All
100
100
100
Resistant
Not Resistant
WIT-PE 500 R
Chemical resistanace
Xx24