TVP MARGIN SUMMARY

TVP Margin of 5 kPa considering Dry Column (Note 2)

TVP Margin of 10 kPa considering Dry Column (Note 2)

No margin on TVP Margin considering Dry Column


(Note 2)

Stabiliser Reboiler Duty

10.24 MW

Stabiliser Reboiler Duty

11.24 MW

Stabiliser Reboiler Duty

9.6 MW

Stabiliser Ovhd Gas Flowrate

30240 kg/h

Stabiliser Ovhd Gas Flowrate

41680 kg/h

Stabiliser Ovhd Gas Flowrate

22580 kg/h

Stabiliser Ovhd Gas Capacity

12.76 MMSCFD

Stabiliser Ovhd Gas Capacity

16.75 MMSCFD

Stabiliser Ovhd Gas Capacity

10.12 MMSCFD

Stabiliser Ovhd Gas Molecular Wt

47.5

Stabiliser Ovhd Gas Molecular Wt

49.86

Stabiliser Ovhd Gas Molecular Wt

44.73

Condensate Production

36998.9 bbl/day

Condensate Production

36815 bbl/day

Condensate Production

37160 BBl/day

Stabiliser Feed/Bottom Exchanger Duty

5.385 MW

Stabiliser Feed/Bottom Exchanger Duty

5.841 MW

Stabiliser Feed/Bottom Exchanger Duty

5.1 MW

Condensate Product Cooler Duty

6.987 MW

Condensate Product Cooler Duty

6.757 MW

Condensate Product Cooler Duty

7.1 MW

TVP Margin of 5 kPa considering Wet Column


(Note 1)

TVP Margin of 10 kPa considering Wet Column


(Note 1)

No margin on TVP Margin considering Wet Column


(Note 1)

Stabiliser Reboiler Duty

10.2 MW

Stabiliser Reboiler Duty

11.24 MW

Stabiliser Reboiler Duty

9.516 MW

Stabiliser Ovhd Gas Flowrate

31270 kg/h

Stabiliser Ovhd Gas Flowrate

42320 kg/h

Stabiliser Ovhd Gas Flowrate

24460 kg/h

Stabiliser Ovhd Gas Capacity

13.44 MMSCFD

Stabiliser Ovhd Gas Capacity

17.48 MMSCFD

Stabiliser Ovhd Gas Capacity

11.01 MMSCFD

Stabiliser Ovhd Gas Molecular Wt

46.62

Stabiliser Ovhd Gas Molecular Wt

48.62

Stabiliser Ovhd Gas Molecular Wt

44.64

Condensate Production

36993 bbl/day

Condensate Production

36817 bbl/day

Condensate Production

37142 bbl/day

Stabiliser Feed/Bottom Exchanger Duty

5.792 MW

Stabiliser Feed/Bottom Exchanger Duty

6.23 MW

Stabiliser Feed/Bottom Exchanger Duty

5.5 MW

Condensate Product Cooler Duty

6.58 MW

Condensate Product Cooler Duty

6.36 MW

Condensate Product Cooler Duty

6.67 MW

Comparision
Stab Reboiler

Impact due to margin of 10 kPa

Impact due to margin of 5 kPa

Same in both cases

Stab Reboiler

17.08%

Stab Reboiler

6.67%

Stab Ovhd Gas Flowrate

Wet case is governing

Stab ovhd Gas Flowrate

41.07%

Stab ovhd Gas Flowrate

4.23%

Stab Ovhd Gas Capacity

Wet case is governing

Stab ovhd Gas Capacity

34.15%

Stab ovhd Gas Capacity

3.15%

Stab Ovhd Gas Ovhd Mol Wt

Dry Case is governing

Stab Ovhd Gas Mol wt

4.22%

Stab Ovhd Gas Mol wt

6.42%

Same in Both Cases

Stab Feed/Bottom Exchanger

22.16%

Stab Feed/Bottom Exchanger

13.57%

Stab Feed Bottom Exchanger

Wet Case is governing

Condensate Prod Cooler

-1%

Condensate Prod Cooler

2%

Cond Prod Cooler Duty

Dry Case is governing

Condensate Production

-3%

Condensate Production

0%

Condensate Production

Note : 1) Wet Column Scenario is considerg bypass of MRU


2) Dry Column Scenario is consideirng MRU in line

You might also like