TE 303TP Quick Reference Guide Usb

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

TE-303TP

Digital Timer

Please visit www.tisch-env.com for a complete TE-303 Digital Timer manual.

TE-303TP DIGITAL TIMER

Setting the Date and Time


1.)
2.)
3.)
4.)
5.)

Press F3 for SETUP


Scroll down to configure, Press ENT
Select DATE, insert date, press ENT
Select TIME, insert time (HHMM), press ENT
Press ESC to return to main status screen.

Setting the Timer


1.) Press F1 for TIMER.
2.) Select DATE, insert start date, press ENT
3.) Select TIME, insert start time (HHMM), press ENT

Please visit www.tisch-env.com for a complete TE-303 Digital Timer manual.

4.) Select DURATION, insert desired duration,


(0003=3 minutes, 0030=30 minutes, 3000=30 hours),
Press ENT
5.) Select repeat, select desired repeat interval,
(1 in 1=sample every day; 1 in 2=sample every other days; 1 in 3=sample every 3 days;1 in 6=sample
every 6 days; 1 in 7=sample every 7 days; or custom sampling schedules {HHMM}),
Press ENT
6.) Select Save and Exit
7.) During a sample the timer can be STOPPED or PAUSED, during a sample press F1 for timer, select
PAUSE or ABORT, select YES or NO to confirm.
The TE-303 digital timer has an internal battery backup so in case of a power failure the timer will remain
set and will continue when power is reapplied. During a power failure the timer will continue to run and
will stop and start exactly as it is programmed (example. If the timer is scheduled to start at 9:00 and run
for 24 hours it will stop exactly 24 hours from the start time regardless of a power failure)
Checking/Resetting the Elapsed Time Indicators(ETI)
The TE-303 has 3 built in ETIs; one ETI is to track motor life, one for calibration frequency, and one for user
based events. The ETIs can be reset at any time and also have a feature that allows the user set alert
reminders for tracking motor life, calibration frequency or user based event.
1.)
2.)
3.)
4.)
5.)

Press F3 for setup


Select ETI, press ENT
To reset ETIs, select desired ETI, press ENT, confirm YES or NO, press ENT
To set ALERT, select desired ETI ALERT, press ENT, enter alert set point, press ENT
Press ESC, to return to main status screen.

Manual Motor Control


The TE-303 digital timer is equipped with a manual motor control feature. This feature allows the user to
turn the motor (or what ever is plugged into to AC out timed cord) to be turned on/off without using the
timer.
1.)
2.)
3.)
4.)
5.)

Press F3 for SETUP.


Select DIAGNOSTICS, press ENT
Select MOTOR, press ENT to toggle the motor on/off
Be sure that the MOTOR is in the OFF position before exiting this menu.
Press ESC to return to main status screen.

Please visit www.tisch-env.com for a complete TE-303 Digital Timer manual.

Save Data to USB drive


Data is stored in a .csv file format which can be viewed using most spreadsheet applications (MS Excel, MS
Spreadsheet).
1.) insert USB memory stick into USB port.
2.) Press F2 for DATA.
3.) Scroll down to save and press ENT
View Data
1.) Press F2 for DATA.
2.) Select VIEW PAST, press ENT
3.) Select desired sample time, pressENT
4.) Use , to view data.
5.) Pres ESC to return to main menu.
View Temperature, Barometric Pressure
1.) Press F3 for setup.
2.) Select DIAGNOSTICS, press ENT
3.) Tamb=Ambient Temperature (Co), Pamb=Ambient Pressure (mm Hg)
4.) Press ESC to return to main screen

Please visit www.tisch-env.com for a complete TE-303 Digital Timer manual.

You might also like