Catalogo Valvulas Yuken

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 124

H

PROPORTIONAL
ELECTRO-HYDRAULIC
CONTROLS
Maximum Flow
Valve Type

Maximum
Operating
Pressure

E Series

EH Series

MPa (PSI)

.5
1

1
3

5
5

10

U.S.GPM
50
100

10

20 30

50

100

24.5 (3550) EHDG-

Relief Valves

24.5 (3550)

EHBG

03

Reducing & Relieving Valves

24.5 (3550)

EHRBG

06

Flow Control (& Check)Valves

24.5 (3550)

EHFG/EHFCG

03

06

Flow Control & Relief Valves

24.5 (3550)

EHFBG

03

06

Directional & Flow Cont.Valves

24.5 (3550)

EHDFG

High Response Type


Directional & Flow Cont.Valves

15.7 (2275)

EHDFG

Pilot Relief Valves

24.5 (3550) EDG-01

Relief Valves

24.5 (3550)

Reducing & Relieving Valves

24.5 (3550)

ERBG

20.6 (3000)

EFG/EFCG (40 Series)

24.5 (3550)

Flow Control (& Check)Valves

Flow Control & Relief Valves

24.5 (3550)

Directional & Flow Cont.Valves

24.5 (3550)

03
06
02

10

10
Pub. EC-1301
10

03
06

06

10

06

EFG/EFCG (10 Series)

03

06

EFBG (40 -10 Series)

03

06

10

EFBG (10 -10 Series)

03

06

10

03

06

EDFHG

03 04

Pub. EC-1302

10

03

EFBG (High Flow Series)

Power Amplifiers/Setting Adjustors

06

04

EBG

Catalogue No.

200 300 500 1000


L /min

Pilot Relief Valves

01

200

06

10

Pub. EC-1303

Pub. EC-1304
Pub. EC-1305

Pub. EC-1301

EH SERIES
PROPORTIONAL ELECTRO-HYDRAULIC
CONTROL VALVES
PROPORTIONAL
Pilot Relief / Relief / Reducing and Relieving /
Flow Control / Flow Control and Relief /
Directional and Flow Control

CONTROLS

Up to 24.5 MPa (3550 PSI), 400 L/min (106 U.S.GPM)

Pilot Relief Valves .................................................. Page 3

Relief Valves ........................................................... Page 4

Reducing and Relieving Valves ............................ Page 5

Flow Control Valves


Flow Control and Check Valves ........................... Page 6
O
M

Flow Control and Relief Valves ............................ Page 7

Y
O
M
V

Directional and Flow Control Valves ................... Page 8


A

High Response Type


Directional and Flow Control Valves ................... Page 9
BAV P

YX

This catalogue introduce the outline of the EH series. Please refer to the catalogue titled "EH Series-Hybrid Components" (Cat. No. Pub.
JC-1320) for the details such as performance characteristics and dimensions.

No.1

EH SERIES

PROPORTIONAL
CONTROLS

Pilot Relief / Relief / Reducing and Relieving /


Flow Control / Flow Control and Relief /
Directional and Flow Control

High-accuracy, simple, convenient


EH Series realizes your dreams.
Why simple ?
5 Pressure display panel (option)

Highly accurate hydraulic control can be


obtained only by supplying 24 V DC power 3
and inputting a command signal voltage of 0 to
5V 4 .4

3 24 V DC
power supply
1 Power amplifier
4 Command signal
voltage input
2 Pressure sensor
incorporated
6 Voltage output for
pressure monitor

7 Alarm signal output

Details of Proportional Electro-hydraulic Relief Valve

Why high-accuracy ?
The power amplifier 1 and pressure sensor 2
are integrated in the control valve.
Furthermore, the closed-loop control 2 design
greatly improves the linearity, hysteresis and
stability in control pressure.

Why convenient ?
1

1. The sensor in directional control valves is to monitor the


spool position. Valves without sensor are also available in
both pressure control valves and directional control valves.
2. Open-loop types are also available.
3. EHDFG-04 and 06: 24V DC power supply is needed.
4. EHDFG-01, 03, 04 and 06: 0 to 5V DC command signal
is needed.
5. EHDFG-04 and 06: The spool displacement is shown as
a percentage.

No.2

Control pressure 5 can be shown digitally on


the optional pressure display panel 5 .
Analog voltages can be output by using the
incorporated sensor for monitoring pressure, etc.
6 5.
Pressure can be displayed remotely with the
Yuken's digital panel metre or any indicators
obtainable in the market and also can be
transmitted into a computer.
If any trouble arises in the system and the
command signal does not match to the output, the
alarm signal 7 is dispatched.
The trouble, if arises, can be easily detected by
monitoring the dispatch of the alarm signal with
sequence controller or computer.

EH SERIES
Pilot Relief Valves
EHDG-01----PNT-50
1/8, Sub-plate Mounting

PROPORTIONAL
CONTROLS

The valve can be used as a pilot valve of the Proportional Electro-Hydraulic


Control Valves.
The valve can also be used as a relief valve for the hydraulic system where
a small flow rate and continuous pressure control are required.

Specifications
Model Numbers

EHDG-01

Description

24.5 MPa (3550 PSI)

Max. Operating Pres.


Max. Flow

2 L /min (.53 U.S.GPM)

Min. Flow

0.3 L /min (.08 U.S.GPM)


Refer to Model Number Designation

Pressure Adjustment Range

10

Coil Resistance

Less than 3% (1%)

Hysteresis

Less than 1%

Repeatability

B : 10 (27) Hz 1
(-90 degree)
C : 10 (27) Hz 1
H : 12 (27) Hz 1
24 V DC
(21 to 28 V DC Included Ripple)
28 W

Frequency Response
Supply Electric Power
Power Input (Max.)

Graphic Symbols

B : 6.9 MPa (1000 PSI) / 5 V DC


C : 15.7 MPa (2275 PSI) / 5 V DC
H : 24.5 MPa (3550 PSI) / 5 V DC
10 k

Input Signal
Input Impedance
Alarm Signal Output
(Open Collector)

Open-Loop Type

Open-Loop Type
with Safety Valve

Open-Loop Type
with Sensor

Open-Loop Type with


Safety Valve & Sensor

Closed-Loop Type

Closed-Loop Type
with Safety Valve

Voltage: Max. 30 V DC
Current: Max. 40 mA
B : 5 V DC / 6.9 MPa (1000 PSI)
C : 5 V DC / 15.7 MPa (2275 PSI)
H : 5 V DC / 24.5 MPa (3550 PSI)
0 - 50C (32 - 122F)
(With Circulated Air)

Pressure Signal Output


Ambient Temperature

1. The value in ( ) is for the closed-loop type.


2. The repeatability of the valve is obtained by having it tested independently on the
conditions similar to its original testing.

Model Number Designation

EHD

-01

-B

-S

-1

-PN

T15

M10

-50

Series
Number

Type of
Mounting

Valve
Size

Applicable
Control

Pres. Adj. Range


MPa (PSI)

Control
Type

DPM

Safety
Valve

P-Line
Orifice

T-Line
Orifice

P-B Line
Orifice

Design
Number

EHD :
Proportional
ElectroHydraulic
Pilot
Relief
Valve

None :
For general
use
G:
Sub-Plate
Mounting

01

V:
Vent
Control of
Relief
Valve
(Omit if not
required)

B: 0.5 - 6.9
(70 - 1000)
C: 1 - 15.7
(145 - 2275)
H: 1.2 - 24.5
(175 - 3550)

None :
OpenLoop

None :
Without
DPM

S:
OpenLoop
with
Sensor
L:
ClosedLoop 1

None :
Without
DPM

1. For closed-loop models, specify applicable control code "V" even


though the valve may not be used as vent control of relief valve.

D:
With
DPM

None :
Without
Safety
PN :
Valve
Without
Orifice
1:
(Standard)
With
Safety
Valve

T15
T13
T11
2

M10 :
Standard
Orifice

50

2. Standard of T-line Orifice.


Pres. Adj. Range B: T15, C: T13, H: T11.

No.3

EH SERIES
Relief Valves
EHBG-03/06/10 (3/8, 3/4, 1-1/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

These valves, consist of a small size but high performance EH series electrohydraulic proportional pilot relief valve and a low noise type relief valve. The
valves control the system pressure proportionally through a controlled input
voltage.

Specifications
Model Numbers

EHBG-03

Description
Max. Operating Pres.

EHBG-06

EHBG-10

24.5 MPa (3550 PSI)


100 L /min
200 L /min
400 L /min
(26.4 U.S.GPM) (52.8 U.S.GPM) (106 U.S.GPM)

Max. Flow
Min. Flow
Pressure Adjustment Range
Coil Resistance
Hysteresis
Repeatability

3 L /min
3 L /min
3 L /min
(.79 U.S.GPM) (.79 U.S.GPM) (.79 U.S.GPM)
Refer to Model Number Designation
10
Less than 2% (1%) 1
Less than 1% 2
C : 10 (22) Hz
H : 10 (25) Hz
(-90 degree)

Frequency Response

1
1

C : 7 (15) Hz 1
H : 9.5 (18) Hz
(-90 degree)

C : 7 (10.5) Hz
H : 6 (14) Hz 1
(-90 degree)

24 V DC
(21 to 28 V DC Included Ripple)
28 W
C : 15.7 MPa (2275 PSI) / 5 V DC
(At Max. Flow)
H : 24.5 MPa (3550 PSI) / 5 V DC
10 k
Voltage: Max. 30 V DC
Current: Max. 40 mA
C : 5 V DC / 15.7 MPa (2275 PSI)
H : 5 V DC / 24.5 MPa (3550 PSI)
0 - 50C (32 - 122F)
(With Circulated Air)

Supply Electric Power


Power Input (Max.)
Input Signal
Input Impedance
Alarm Signal Output
(Open Collector)
Pressure Signal Output
Ambient Temperature

Graphic Symbols

Open-Loop Type

Open-Loop Type with Sensor

1. The value in ( ) is for the closed-loop type.


2. The repeatability of the valve is obtained by having it tested independently on the conditions
similar to its original testing.

Closed-Loop Type

Model Number Designation

EHB

-03

-C

-S

-50

Series Number

Type of
Mounting

Valve
Size

Pres. Adj. Range


MPa (PSI)

Control
Type

DPM

Design
Number

EHB :
Proportional ElectroHydraulic Relief Valve

G:
Sub-Plate
Mounting

03

C: 0.6 [0.8] - 15.7 (85 [115] - 2275)


H: 0.6 [0.8] - 24.5 (85 [115] - 3550)

06

C: 0.9 [1.0] - 15.7 (130 [145] - 2275)


H: 0.9 [1.0] - 24.5 (130 [145] - 3550)

10

C: 1.1 [1.4] - 15.7 (160 [205] - 2275)


H: 1.1 [1.4] - 24.5 (160 [205] - 3550)

None :
Open-Loop

None :
Without DPM

50

S : Open-Loop
with Sensor
L:
Closed-Loop

None :
Without DPM
D:
With DPM

50

Each value of minimum adjustment pressure is of at 50% flow rate of the Max. Flow shown on the Specifications.
The value in [ ] is for the closed-loop type.

No.4

50

EH SERIES
Reducing & Relieving Valves
EHRBG-06/10 (3/4, 1-1/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

These valves consist of a small size but high performance electro-hydraulic


proportional pilot relief valve and reducing valve with relief function. The valves
control the system pressure proportionally through a controlled input voltage.
Moreover, a good response speed in reducing the pressure even at a large load
capacity can be obtained with the relief function of the valves.

Specifications
Model Numbers

EHRBG-06

Description
Max. Operating Pres.
Max. Flow
Max. Relieving Flow
Pressure Adjustment Range
Coil Resistance
Hysteresis
Repeatability

EHRBG-10

24.5 MPa (3550 PSI)


100 L /min
250 L /min
(26.4 U.S.GPM)
(66 U.S.GPM)
35 L /min 1
15 L /min 1
(9.24 U.S.GPM)
(3.96 U.S.GPM)
Refer to Model Number Designation
10
Less than 3%
Less than 1% 2
B : 4 Hz
C : 3 Hz
H : 3 Hz

Frequency Response

(-90 degree)

24 V DC
(21 to 28 V DC Included Ripple)
28 W

Supply Electric Power


Power Input (Max.)
Input Signal

Graphic Symbols

B : 6.9 MPa (1000 PSI) / 5 V DC


C : 13.7 MPa (2000 PSI) / 5 V DC
H : 20.6 MPa (3000 PSI) / 5 V DC
(at Flow Rate Zero)
10 k

Input Impedance
Pressure Signal Output

B : 5 V DC / 6.9 MPa (1000 PSI)


C : 5 V DC / 13.7 MPa (2000 PSI)
H : 5 V DC / 20.6 MPa (3000 PSI)

Ambient Temperature

0 - 50C (32 - 122F)


(With Circulated Air)

Open-Loop Type

1. The figures shown are those obtained where the differential pressure between the secondary
pressure port and tank port is 14 MPa (2030 PSI).
2. The repeatability of the valve is obtained by having it tested independently on the conditions
similar to its original testing.

Open-Loop Type with Sensor

Model Number Designation

EHRB

-06

-C

Series Number

Type of
Mounting

Valve
Size

Pres. Adj. Range


MPa (PSI)

EHRB :
Proportional Electro-Hydraulic
Reducing & Relieving Valve

-S
Control Type

-50

DPM

Design
Number

06

B: 0.8 - 6.9 (115 - 1000)


C: 1.2 - 13.7 (175 - 2000)
H: 1.5 - 20.6 (220 - 3000)

None :
Open-Loop

None :
Without DPM

50

10

B: 0.9 - 6.9 (130 - 1000)


C: 1.2 - 13.7 (175 - 2000)
H: 1.5 - 20.6 (220 - 3000)

S : Open-Loop
with Sensor

D : With DPM

50

G:
Sub-Plate
Mounting

No.5

EH SERIES
Flow Control (and Check) Valves
EHFG/EHFCG-03/06 (3/8, 3/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

The system flow rate can be controlled remotely as desired by regulating


input voltage. Further, since pressure and temperature compensation
functions are provided, the preselected flow rate is not affected by pressure
(load) or temperature (fluid viscosity).

Specifications
Model Numbers
Description
Max. Operating Pres.
MPa (PSI)
Max. Metred Flow
L /min (U.S.GPM)
Min. Metred Flow
L /min (U.S.GPM)
Min. Differential Pressure 1
MPa (PSI)
Free Flow
L /min (U.S.GPM)
(Only with Check Valve)
at Normal
Pilot Flow
L /min (U.S.GPM) at Transition
Min. Pilot Pressure
MPa (PSI)

60
EHFG-03- 125

EHFG-06-250

20.6 (3000)

24.5 (3550)

60 : 60 ( 15.8)
125 : 125 ( 33)

250 (66)

1 (.26)

2.5 (.66)

1.0 (145)

1.0 (145)

130 (34.3)

280 (73.9)

0.5 ( .13)
2.6 ( .69)

1 ( .26)
4 ( 1.06)

1.0 (145)

1.5 (215)

Frequency Response

Graphic Symbols

12 Hz (-90 degree)

Hysteresis

Less than 3%

Repeatability

Less than 1%

EHFG
2

10

Coil Resistance
Supply Electric Power

24 V DC
(21 to 28 V DC Included Ripple)

O
O

28 W

Power Input (Max.)

Max. Metred Flow / 5V DC

Input signal

Internal Pilot

External Pilot

10 k

Input Impedance

0 - 50C (32 - 122F)


(With Circulated Air)

Ambient Temperature

EHFCG

1. Minimum differential pressure means fine pressure compensation at inlet and outlet port.
2. The repeatability of the valve is obtained by having it tested independently on the
conditions similar to its original testing.

O
O

Internal Pilot

External Pilot

Model Number Designation

EHF

-03

-60

-E

-50

Series Number

Type of
Mounting

Valve Size

Max. Metred Flow


L /min (U.S.GPM)

Pilot Connection

Design
Number

03

60 : 60 ( 15.8)
125 : 125 ( 33)

None :
Internal Pilot

06

250 : 250 ( 66)

E:
External Pilot

EHF :
Proportional Electro-Hydraulic
Flow Control Valve
EHFC :
Proportional Electro-Hydraulic
Flow Control and Check Valve

No.6

G:
Sub-Plate
Mounting

50

50

EH SERIES
Flow Control and Relief Valves
EHFBG-03/06/10 (3/8, 3/4, 1-1/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

These are proportional electro-hydraulic flow control valves having functions for
controlling the direct electric current of metre-in type and for pressure control.
They are energy-saving valves for supplying the minimal pressure and flow
required to operate actuators.

Specifications
Model Numbers
Description

60
EHFBG-03- 125

EHFBG-06-250

EHFBG-10-500

Flow Controls

24.5 (3550)
24.5 (3550)
Max. Operating Pressure MPa (PSI)
24.5 (3550)
Max. Flow
60 : 60 ( 15.8)
250 (66)
500 (132)
L /min (U.S.GPM) 125 : 125 ( 33)
1-60(.26-15.8)
60
:
Metred Flow Capacity
2.5-250 (.66-66) 5-500 (13.2-132)
L /min (U.S.GPM) 125: 1-125(.26-33)
1.5 (215)
1.5 (215)
1.5 (215)
Min. Pilot Pressure
MPa (PSI)
1 (.26)
1
(.26)
1
(.26)
at
Normal
Pilot Flow
L /min (U.S.GPM) at Transition
6 (1.59)
4 (1.06)
3 (.79)
0.9 (130)
0.7 (100)
0.6 (85)
Differential Pressure
MPa (PSI)
Hysteresis
Less than 3%
Repeatability
Less than 1%
Input Signal
Max. Flow / 5 V DC
Coil Resistance
10
Supply Electric Power
24 V DC (21 to 28 V DC Included Ripple)
Input Impedance
10 k
Power Input (Max.)
28 W

Pressure Controls

Pres. Adj. Range Adj. Range: C 1.2-15.7 (175-2275) 1.4-15.7 (200-2275) 1.5-15.7 (215-2275)
MPa (PSI)
Adj. Range: H 1.4-24.5 (200-3550) 1.4-24.5 (200-3550) 1.5-24.5 (215-3550)
Less than 2%
Hysteresis
Less than 1%
Repeatability
10
Coil Resistance
Max. Operating Pres. / 5 V DC
Input Signal
24 V DC (21 to 28 V DC Included Ripple)
Supply Electric Power
10 k
Input Impedance
28 W
Power Input (Max.)
C : 5 V DC / 15.7 MPa (2275 PSI)
Output Signal
H : 5 V DC / 24.5 MPa (3550 PSI)
0 - 50C (32 - 122F)
Ambient Temperature
(With Circulated Air)
The repeatability of the valves is obtained by having it tested independently on the conditions
similar to its original testing.

Graphic Symbols
A

A
Y

O
M

O
M

Models with
Proportional Pilot
Relief Valves

Models with
Proportional Pilot
Relief Valves and
Sensor

A
Y
O
M
V
X
O
M

Models without
Proportional Pilot
Relief Valves

External Pilot Pres.


Connection

Model Number Designation

EHFB

-03

-60

-C

-E

-S

-50

Series
Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

Pilot Relief Valve


Pres. Adj. Range

Pilot Connection
of Flow Control

Pressure
Controls

DPM of
Pres.

Design
Number

03

60 : 60 ( 15.8)
125 : 125 ( 33)

None :
Internal Pilot

None :
Open-Loop

E:
External Pilot

S:
Open-Loop D :
with Sensor With DPM

EHFB :
Proportional
ElectroHydraulic
Flow Control
and Relief
Valve

G:
Sub-Plate
Mounting

06
10

250 : 250 ( 66)


250 : 500 ( 132)

None :
Without Proportional Pilot Relief
Valve
C, H :
See Specifications

None :
Without
DPM

50
50
50

DMP is available only for the models with Pressure Controls "S".

No.7

EH SERIES
Directional and Flow Control Valves
EHDFG-01/03 (1/8, 3/8)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

These valves incorporate two control functions - flow and direction - which
simplify the hydraulic circuit composition and therefore the cost of the
system is reduced.

Specifications
Model Numbers
Description
Max. Operating Pressure

MPa (PSI)

EHDFG-01

EHDFG-03

24.5 (3550)

24.5 (3550)

7 (1020)

7 (1020)

30 (7.92)

60 (15.9)

Max. Tank Line Back Pres. MPa (PSI)


Rated Flow
L /min (U.S.GPM)
[Valve P 6.9 MPa (1000 PSI)]
Hysteresis

Less than 5%

Repeatability

Less than 1%

Frequency Response

20 (-90 deg.) Hz

17 (-90 deg.) Hz

10.5

8.0

Coil Resistance

24 V DC
(21 to 28 V DC Included Ripple)

Supply Electric Power

Input
Voltage

Graphic Symbols
Metre-in Metre-out Control
A

By Controlling Variable
Resistance
(Using of Power from Amp.)

1 - 2 k Volume Range
0 ~ -5 V for SOL a
0 ~ +5 V for SOL b

Input Impedance

10 k

Power Input (Max.)

40 W
45 W
0 - 50C (32 - 122F)
(With Circulated Air)

Ambient Temperature

A
b

By Controlling Voltage
(Using of Power outside Amp.)

3C2

10 k

3C40
Metre-out Control

The repeatability of the valves is obtained by having it tested independently on the con-ditions
similar to its original testing.

3C2

3C40
Metre-in Control

3C2

3C40

Model Number Designation

EHDFG

-01

-30

Series Number

Valve Size

Rated Flow
L /min (U.S.GPM)

01

30 : 30 (7.92)

3C2

03

60 : 60 (15.9)

3C40

EHDFG :
Proportional Electro-Hydraulic
Directional and Flow Control
Valve (Sub-Plate Mounting)

Spool Type

-E

-30

Direction of Flow

Design
Number

XY : Metre-in
Metre-out

30

X : Metre-in

Spool type shown in the column is for the centre position.

No.8

-3C2

Y : Metre-out

30

EH SERIES
High Response Type
Directional and Flow Control Valves
EHDFG-04/06 (1/2, 3/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

These valves pursue the ultimate performance of proportional electrohydraulic directional & flow control valves and make themselves to have
high response features.
The closed-loop is composed in the valve inside by combination of a
differential transformer (LVDT) and a power amplifier. Thus, high accuracy and reliability are provided.
In addition to control in the open-loop, these can be used for the closed-loop
system as simplified servo valves.

Specifications
Model Numbers
Description
Max. Operating Pres.

MPa (PSI)

EHDFG-04

EHDFG-06

15.7 (2275)

15.7 (2275)

130 (34.3)

280 (73.9)

1.5 (215)

1.5 (215)

Rated Flow
L /min (U.S.GPM)
Valve Pres. Difference: 1.5 MPa (215 PSI)
Min. Required Pilot Pres.
MPa (PSI)
Min. Required Pilot Flow
L /min (U.S.GPM)
Max. Drain Line Back Pres.

at Normal

2 (.53)

2 (.53)

at Transition

6 (1.59)

10 (2.64)

MPa (PSI)

0.1 (15)

Models without Pressure


Compensator Valve

0.1 (15)

Hysteresis

Less than 1%

Repeatability

Less than 1%

Frequency Response

Graphic Symbols

55 Hz (-90 deg.)

45 Hz (-90 deg.)

30

30

Coil Resistance

BAV P

24 V DC

Supply Electric Power

Internal Pilot

( 21 to 28 V DC Included Ripple)
Rated Flow / 5 V DC

Input Signal

10 k

Input Impedance

10 k

20 W
20 W
Voltage: Max. 30 V DC
Current: Max. 30 mA
5
V
DC / Rated Travel of Spool

Power Input (Max.)


Alarm Signal Output (Open Collector)
LVDT Output (Sensor Monitor)

BAV P

0 - 50C (32 - 122F)


(With Circulated Air)

Ambient Temperature

YX

External Pilot

Models with Pressure


Compensator Valve

The repeatability of the valves is obtained by having it tested independently on the con-ditions
similar to its original testing.

BA

Internal Pilot

Model Number Designation

EHDFG

-04

-130

Series Number

Valve
Size

Rated Flow
L /min (U.S.GPM)

04

130 : 130 (34.3)

06

280 : 280 (73.9)

EHDFG :
Proportional ElectroHydraulic Directional
and Flow Control
Valve
(Sub-Plate Mounting)

-2

-D

-CB

-10

Pilot
Connection

DPM

Relief Type Pres.


Compensator

Design
Number

None :
Internal Pilot

None :
Without DPM

None :
Not Provided

10

40

E:
External Pilot

D:
With DPM

CB :
Provided

10

Spool Type

-E

Spool type shown in the column is for the centre position.

No.9

Pub. EC-1302

E SERIES
PROPORTIONAL PRESSURE CONTROLS PROPORTIONAL
Pilot Relief / Relief / Reducing and Relieving

CONTROLS

Up to 24.5 MPa (3550 PSI), 400 L/min (106 U.S.GPM)

Proportional pressure control valves control the system pressure proportionally through a controlled input current from
the amplifier. Therefore, the continuous and stepless pressure control can be obtained even with a single valve. the valves
are of help not only to simplify the system design but also to eliminate any shocks in the hydraulic system.

Pilot Relief Valves ................................................. Page 4


These valves are composed of a small DC solenoid and a directacting type relief valve. As a relief valve for a hydraulic system of
small flow capacity or a pilot valve to electro-hydraulic proportional
control valves, the valves are able to control the pressure in proportion to an input current.

Relief Valves .......................................................... Page 11


These valves consist of a small size but high performance 1/8
electro-hydraulic proportional pilot relief valve and a relief valve
specially developed as low noise type. The valves can control the
pressure in a hydraulic system proportionally through a controlled
input current.

Reducing and Relieving Valves ........................... Page 21


These valves consist of a small size but high performance 1/8
electro-hydraulic proportional pilot relief valve and a reducing
valve with relief function. The valves can control the pressure in a
hydraulic system proportionally through a controlled input current.
As the valves have a relieving mechanism, a good rsponse speed in
reducing the pressure even at a large load capacity can be obtained.

No.1

E SERIES
PRESSURE CONTROL VALVES
Pilot Relief / Relief / Reducing and Relieving

PROPORTIONAL
CONTROLS

Hydraulic Fluids

Hydraulic Fluids
Fluid Types
Any type of hydraulic fluid listed in the table below can be used.
Petroleum Base Oils

Use fluids equivalent to ISO VG 32 or VG 46.

Synthetic Fluids

Use phosphate ester or polyol ester fluids. When phosphate ester fluid is used, prefix "F-" to the
model number because the special seals (fluororubber) are required to be used.

Water-containing Fluids

Use water-glycol fluid.

Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

Recommended Fluid Viscosity and Temperature


Use hydraulic fluids which satisfy the both recommended viscosity and oil temperatures given in the table below.
Name

Viscosity

Temperature

Pilot Relief Valves


Relief Valves
Reducing and Relieving Valves

15 - 400 mm2/s
(77 - 1800 SSU)

-15 - +70C
(5 - 160F)

Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
11. Use 20 m or finer line filter.

No.2

E SERIES
PRESSURE CONTROL VALVES

PROPORTIONAL
CONTROLS

Pilot Relief / Relief / Reducing and Relieving


Instructions
Mounting

Be sure that the air vent faces up.


In addition, if the valve is mounted vertically, the minimum adjustment pressure is 2 MPa (290 PSI) or higher.
[Good example]

[Bad example]
Air Vent

SOL

Air Vent
SOL

SOL

Air Vent

Air Bleeding
To ensure stable control, bleed the air from solenoid
completely and fill its core with oil.
Bleeding can be done by slowly loosening one of the air
vents at the end of the solenoid. Choose one of the three
air vents which is expected to work most effectively (see
the figure to the right).

Solenoid
Air Vent
3 Places

Manual Adjustment Screw


When initial adjustments are to be made or when no
current is supplied to the valve due to electrical failure
or other problem, turn the manual pressure adjustment
screw to temporarily set the valve pressure. In that case,
when turn the manual pressure adjustment screw
clockwise, the valve pressure rises. Under normal
condition, however, this screw must be kept in its original
position (see the figure to the right).

Manual Pressure Adj. Screw

10 Series Solenoid

Tank and Drain Piping


The tank-line back pressure and drain back pressure directly affect the minimum adjustment pressure. Therefore, do
not connect the tank or drain pipes to other lines, but connect them directly to the reservoir maintaining the back pressure
as low as possible. Be sure that the tank and drain pipe ends are immersed in fluid.

Hysteresis and Repeatability Value Indications


The hysteresis and repeatability values indicated in the specifications for each control valve are determined under the
following conditions:
Hysteresis Value: Obtained when Yuken's applicable power amplifier is used.
Repeatability Value: Obtained when Yuken's applicable power amplifier is used under the same conditions.

No.3

E Series
Pilot Relief Valves
EDG-01---PNT-51/5190
1/8, Sub-plate Mounting

PROPORTIONAL
CONTROLS

Specifications / Model Number Designation

Specifications
Model Numbers

EDG-01

Description
Max. Operating Pres.

24.5 MPa (3550 PSI)

Max. Flow

2 L /min (.53 U.S.GPM)

Min. Flow

0.3 L /min (.08 U.S.GPM)

Pressure Adj. Range MPa (PSI)

Refer to Model Number Designation


EDG-01-B : 800 mA
EDG-01-C : 900 mA
EDG-01-H : 950 mA

Rated Current

10

Coil Resistance
Hysteresis

Less than 3%

Repeatability

Less than 1%

Approx. Mass

2 kg (4.4 lbs.)

Model Number Designation

ED
Series Number

ED :
Proportional
ElectroHydraulic
Pilot Relief
Valve

G
Type of
Mounting

G:
Sub-plate
Mounting

-01
Valve
Size

01

V
Applicable
Control 1

-C

-1

Pressure Adj. Range


MPa (PSI)

Safety
Valve

None :
General use

B: 0.5 - 6.9 ( 70 - 1000)

V:
Vent Control of
Relief Valve
(Omit if not
required)

C: 1.0 - 15.7 ( 145 - 2275)

H: 1.2 - 24.5 ( 175 - 3550)

-PN
P-Line
Orifice

None :
Without
Safety
PN :
Valve
Without
Orifice
1:
(Standard)
With
Safety
Valve

T13
T-Line
Orifice

-51

Design
Number

Design
Standards

T15

T13

51

Refer to

T11

1. When the valve is to be used for vent control purpose, orifice adjustment is required due to piping capacity limitations. Therefore, consult your
Yuken representative in advance.
2. The orifice used as the pilot valve may differ from the standard orifice.
3. Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Graphic Symbols

Without Safety Valve

No.4

With Safety Valve

E Series
Pilot Relief Valves
EDG-01

PROPORTIONAL
CONTROLS

Sub-plate / Instructions / Others


Attachment

Applicable Power Amplifier

Mounting Bolts
Four socket head cap screws in the table below are
included.

For stable performance, it is recommended that Yuken's


applicable power amplifiers be used (for details see
Catalogue No. Pub. EC-1305).
Model Numbers: AME-D-10--20
AME-D2-1010--10
SK1022---11
SK1015-11 (For DC power supply)
AMN-D-10 (For DC power supply)

Descriptions

Soc. Hd. Cap Screw

Japanese Standard "JIS"


European Design Standard
N. American Design Standard

M5 45 Lg.
No. 10 - 24 UNC 1-3/4 Lg.

Sub-plate
Japanese Standard "JIS"

European Design Standard

Piping Size

Sub-plate
Model Numbers

Thread
Size

1/8

DSGM-01-30

Rc 1/8

DSGM-01-3080

1/8 BSP.F

1/4

DSGM-01X-30

Rc 1/4

DSGM-01X-3080

1/4 BSP.F

3/8

DSGM-01Y-30

Rc 3/8

Sub-plate
Model Numbers

N. American Design Standard


Thread
Size

Approx.
Mass
kg (lbs.)

DSGM-01-3090

1/8 NPT

0.8 (1.8)

DSGM-01X-3090

1/4 NPT

0.8 (1.8)

DSGM-01Y-3090

3/8 NPT

0.8 (1.8)

Thread
Size

Sub-plate
Model Numbers

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the
mounting surface should have a good machined finish.

Instructions

Vent Control
When the valve is used for vent control of relief valves
or others, use the pipes of 6 mm (.24 in.) ID. 300 mm
(11.8 in.) or less length for connection.
If the pressure is instable, provide a 1 to 1.5 mm (.04 to
.06 in.) diameter orifice to the vent port of the relief
valves or others.
Circuit Pressure Control
When the pressure in a circuit is directly controlled with
this valve, set the trapped oil volume being more than
40 cm3 (2.44 cu. in.).

Safety Valve Pressure Setting


The pressure of the safety valve at the maximum flow is
preset at the value equal to the upper limit of the pressure
adjustment range plus 2 MPa (290 PSI).
In case where the upper limit of operating pressure is low
or the upper limit of flow rate to be used is different from
the specified maximum flow, please adjust and determine
the setting pressure of the safety valve at the value
calculated from the following formula.
Setting pressure = (Operating pressure upper limit) +
(Additional pressure indicated below)
PSI
300

Additional Pressure

Tank-Line Back Pressure


Check that the tank line back pressure does not exceed
0.2 MPa (29 PSI).

MPa
2.0

225
150

1.0

75
0

0
0

2 L /min

.25

.50 U.S.GPM

Flow Rate

To lower the setting pressure, turn the safety valve


pressure adjustment screw anti-clockwise.
After
adjustment, be sure to tighten the lock nut.

No.5

E Series
Pilot Relief Valves
EDG-01

PROPORTIONAL
CONTROLS

Installation Drawing
EDG-01--1-PNT-51/5190

EDG-01--PNT-51/5190

With Safety Valve

Without Safety Valve

Fully Extended 216(8.50)

5.5(.22) Dia. Through


9.5(.37) Dia. C'Bore
4 Places

79(3.11)
Pressure Adj.
Screw for
Safety Valve
3(.12) Hex.Soc.

40.5
(1.59)

20.5
(.81)

0.75
(.03)
8.5
(.33)

Fully Extended
52
(2.05)

Lock Nut
10(.39) Hex.

31
(1.22)
32.5
(1.28)
48
(1.89)

INC.

Pressure Port "P"


The direction can be altered
to every 90 degree angles.

Tank Port "T"

For other dimensions, refer to the without safety valve.

DIMENSIONS IN
MILLIMETRES (INCHES)
Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area . . .
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Connector
(The direction can be altered
to every 90 degree angles.)

190.5
(7.50)

27.5
(1.08)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

No.6

INC.

26.5
(1.04)

Mounting Surface
(O-Rings Furnished)

50
(1.97)

37.5
(1.48)

25
(.98)

94.5
(3.72)

Air Vent
3(.12) Hex. Soc.
3 Places

86.7
(3.41)

57.5
(2.26)

39
(1.54)

E Series
Sub-plate for Pilot Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing

Sub-plates
DSGM-01-30/3080/3090

40.5(1.59)
30.2(1.19)

14.2
(.56)

"D" Thd. "E" Deep


4 Places

32
(1.26)

21.5(.85)

16
(.63)
15
(.59)

7.5
(.30)

8.5
(.33)

15.5
(.61)

0.75
(.03)

12.7(.50)

"C" Thd.
4 Places

71
(2.80)
85
(3.35)

7
(.28)

37
(1.46)
24
(.94)

63
(2.48)

T
11
(.43)

25.8
(1.02)
31
(1.22)
31.75
(1.25)
48
(1.89)

P
5.2
(.20)

7(.28) Dia.
4 Places

7(.28) Dia. Through


11(.43) Dia. Spotface
2 Places

12.5
(.49)
35.5
(1.40)
58.5
(2.30)

DIMENSIONS IN
MILLIMETRES (INCHES)

Sub-plate
Model Numbers
DSGM-01-30

Thread Size
"C" Thd.
"D" Thd.
Rc 1/8

DSGM-01-3080

1/8 BSP.F

DSGM-01-3090

1/8 NPT

DSGM-01X-30

Rc 1/4

M5

10 (.39)

No.10-24 UNC

12 (.47)

M5

10 (.39)

DSGM-01X-3080

1/4 BSP.F

DSGM-01X-3090

1/4 NPT

No.10-24 UNC

12 (.47)

Rc 3/8

M5

10 (.39)

3/8 NPT

No.10-24 UNC

12 (.47)

DSGM-01Y-30
DSGM-01Y-3090

"E"
mm (in.)

No.7

E SERIES
Pilot Relief Valves
EDG-01

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Step Response (Example)

Flow Rate
: 2 L /min (.53 U.S. GPM)
Trapped Oil Volume : 40 cm3(2.44 cu. in.)
Viscocity
: 30 mm2/s (141 SSU)

These Characteristics have been obtained by measuring on each valve.


Therefore, they may vary according to a hydraulic circuit to be used.
MPa
9

EDG-01-B

1200

0.2s

600
3

400
200

Step Signal

25

2000
12

0.2s

1500
8

1000

20

-10
-20
-30

40

Min. Adjustment Pressure

MPa
2.5

3000

EDG-01-H
2.0

Gain
2500
Pressure

Phase

1.5
2000

1500

:
:
:
:

2 L /min (.53 U.S. GPM)


7.8 1.6 MPa (1130 230 PSI)
30 cm3(1.83 cu. in.)
30 mm2/s (141 SSU)

EDG-01-C

0.5
500
EDG-01-B

200

0.15

200

800

Input Current mA

EDG-01-B

0.1
0.5
0
0

.25

.50
Flow Rate

3 L /min
.75

U.S.GPM

Flow Rate vs. Pressure

Viscosity vs. Pressure


Flow Rate : 2 L /min (.53 U.S. GPM)
Oil : ISO VG 46 Oil

Viscosity : 30 mm2/s (141 SSU)


MPa

2200
2000

15.7
14.2
12.7

1000
800
600

6.9
5.4
3.9

3000
3550

MPa
24.9
24.5
24.1

2350
2300
2250

16.1
15.7
15.3

PSI
EDG-01-H

24.5
23.0
21.5

EDG-01-C

Pressure

PSI
3600
3400
3200

EDG-01-B

EDG-01-H

EDG-01-C

EDG-01-B

1050
1000
950

L /min

7.3
6.9
6.5
0
Temperature

35

40

90 100
70 60 50 40
0

No.8

600

EDG-01-C

Pressure

400

EDG-01-H

0.25
0.2

MPa
0.3

300

1.0

1000

Viscosity : 30 mm2/s (141 SSU)

Time

PSI
3500

70

Min. Adjustment Pressure

100

Control Pressure vs. Input Current

Gain (dB)

Phase (deg.)

0.2

Step Signal

10

Time

Frequency (Hz)
0.4 0.7 1
2
4
7 10

Flow Rate
Pressure
Trapped Oil Volume
Viscocity

PSI

0.2s
15

2000

Frequency Response

400

20

Step Signal

Time

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

3000

1000

0.1

EDG-01-H

MPa
30

16
Pressure

Pressure

800

PSI
4000

1000

EDG-01-C

MPa
20

PSI
2750
2500

Pressure

PSI

.25
Flow Rate

.50

U.S.GPM

45

50

55

120
30 25

60

140 F
20 mm2/s

Viscosity
300 250 200

150 125

100

SSU

1000

E Series
Pilot Relief Valves
EDG-01

PROPORTIONAL
CONTROLS

Spare Parts List and Pilot Valves


Without Safety Valve

EDG-01--PNT-51/5190
EDG-01V--PNT-5103

EDG-01--PNT-5101

12
21 16 20

24

13 18

5 22 15

11 28

17

17

25 15

With Safety Valve

EDG-01--1-PNT-51/5190
EDG-01V--1-PT-5103
1

19 10 14 27 26

Pilot Valves
2

The table shows the proportional control valves (main


valves) and corresponding pilot relief valves to be used
onto the main valves.

List of Seals
Item
14
15
16
17
18
19
20
21

Name of Parts
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Fastener Seal

Part Numbers
SO-NA-P6
SO-NB-P9
SO-NB-P7
SO-NB-P14
SO-NB-P18
SO-NB-A013
SO-NB-P22
SO-FCF-4

Qty.
1
2
1
1
1
1
1
1

Remarks

Included in
Seal Kit
Kit No.:
KS-EDG-01-51

Note) O-ring (Item 16, 18, 20) and the fastener seal (Item 21) are
included in the solenoid assembly.

Solenoid Ass'y
Valve Model Numbers
EDG-01---PNT-51/5190
EDG-01---PNT-5101

EDG-01V---PNT-51/5190
EDG-01V---PT-5103

13 Solenoid Ass'y

E318-Y06M1-28-61
E318-Y06M1-05-61
E318-Y06M1-04-61

Note) The connector assembly GDM-211-B-11 (Item 12) is not


included in the solenoid assembly.

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

Main Valve Model Numbers

Pilot Valve Model Numbers

EBG-03-C-51/5190
EBG-03-H-51/5190
EBG-03-C-T-51/5190
EBG-03-H-T-51/5190
EBG-06-C-51/5190
EBG-06-H-51/5190
EBG-06-C-T-51/5190
EBG-06-H-T-51/5190
EBG-10-C-51/5190
EBG-10-H-51/5190
EBG-10-C-T-51/5190
EBG-10-H-T-51/5190
ERBG-06-B-51/5190
ERBG-06-C-51/5190
ERBG-06-H-51/5190
ERBG-10-B-51/5190
ERBG-10-C-51/5190
ERBG-10-H-51/5190
EFBG-10-500-C-17/1790
EFBG-10-500-H-17/1790
EFBG-10-500-C--51/5190
EFBG-10-500-H--51/5190
EFBG-06-500-C--51/5190
EFBG-06-500-H--51/5190

EDG-01V-C-1-PNT09-51
EDG-01V-H-1-PNT09-51
EDG-01V-C-PNT09-51
EDG-01V-H-PNT09-51
EDG-01V-C-1-PNT10-51
EDG-01V-H-1-PNT10-51
EDG-01V-C-PNT10-51
EDG-01V-H-PNT10-51
EDG-01V-C-1-PNT11-5103
EDG-01V-H-1-PNT11-5103
EDG-01V-C-PNT11-5103
EDG-01V-H-PNT11-5103
EDG-01-B-PNTN-5101
EDG-01-C-PNTN-5101
EDG-01-H-PNT15-5101
EDG-01-B-PNTN-5101
EDG-01-C-PNTN-5101
EDG-01-H-PNT15-5101
EDG-01V-C-1-P18T17-5103
EDG-01V-H-1-PNT13-5103
EDG-01V-C-1-PNT12-5103
EDG-01V-H-1-PNT12-5103
EDG-01V-C-1-PNT11-5103
EDG-01V-H-1-PNT11-5103

No.9

E Series
Pilot Relief Valves
EDG-01

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
EDG-01 series valve has changed model from 50 to 51 design in line with the solenoid improvement.
Specifications and Characteristics
No change in specifications and characteristics between current and new design.
Mounting Interchangeability
There is an interchangeability in the mounting dimensions, however, the outside shape and dimensions are changed as
shown below due to solenoid improvement and other modifications.

Current: Design 50
191.5
(7.54)
26.5
(1.04)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.
Adaptor
22(.87) Hex.

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

Solenoid Ass'y
1 E318---50
2 E318---60
Fully Extended 217(8.54)

Fully
Extended
52
(2.05)

Air Vent
3(.12) Hex. Soc.
3 Places

The solenoid assembly current design comes in two types: 1 E318-50 design and 2 60 design.
See the figure on the left for an external view of type 1 . See the figure on the right for type 2 .

No.10

190.5
(7.50)
86.7
(3.41)

26.5
(1.04)

94.5
(3.72)

86.6
(3.41)

94.5
(3.72)

Air Vent
3(.12) Hex. Soc.

New: Design 51

Solenoid Ass'y
E318---61
Fully Extended 216(8.50)

Fully
Extended
52
(2.05)

E Series
Relief Valves
EBG-03/06/10 (3/8, 3/4, 1-1/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

Specifications / Model Number Designation


Specifications
Model Numbers
Description
Max. Operating Pres.
MPa (PSI)
Max. Flow
L /min(U.S.GPM)
Min. Flow
L /min(U.S.GPM)

EBG-03

EBG-06

EBG-10

24.5 (3550)

24.5 (3550)

24.5 (3550)

100 (26.4)

200 (52.8)

400 (106)

3 (.79)

3 (.79)

3 (.79)

Pressure Adjustment Range

Refer to Model Number Designation

MPa (PSI)

C : 770 mA
H : 820 mA

C : 750 mA
H : 800 mA

C : 730 mA
H : 780 mA

10

10

10

Hysteresis

Less than 3%

Less than 3%

Less than 3%

Repeatability

Less than 1%

Less than 1%

Less than 1%

5.6 (12.3)

6.3 (13.9)

10 (22)

Rated Current
Coil Resistance

Approx. Mass

kg (lbs.)

Model Number Designation

EB

-03

-C

Series Number

Type of
Mounting

Valve
Size

Pres. Adj. Range


MPa (PSI)

03
EB :
Proportional
Electro-Hydraulic
Relief Valve

G:
Sub-plate
Mounting

06
10

C: - 15.7
( - 2275)
1

H: - 24.5
( - 3550)

-T

-51

Safety Valve

Design
Number

Design
Standards

None :
With
Safety Valve
T:
Without
Safety Valve

51

Refer to

1. Min. adjustment pressure shall be referred to the curves on page 16.


2. Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Graphic Symbols

Without Safety Valve

With Safety Valve

No.11

E Series
Relief Valves
EBG-03/06/10

PROPORTIONAL
CONTROLS

Sub-plate / Instructions / Others


Attachment
Mounting Bolts
Socket Head Cap Screw

Valve
Model Numbers

Japanese Standard "JIS" & European Design Standard

N. American Design Standard

Qty.

EBG-03

M12 40 Lg.

1/2 - 13 UNC 1-1/2 Lg.

EBG-06

M16 50 Lg.

5/8 - 11 UNC 2 Lg.

EBG-10

M20 60 Lg.

3/4 - 10 UNC 2-1/4 Lg.

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
Catalogue No. Pub. EC-1305).
SK1015-11 (For DC power supply)
Model Numbers: AME-D-10--20
AME-D2-1010--10
AMN-D-10 (For DC power supply)
SK1022---11

Sub-plate
Japanese Standard "JIS"

Valve
Model
Numbers
EBG-03
EBG-06

Sub-plate
Model Numbers

Thread
Size

Sub-plate
Model Numbers

BGM-03-20

Rc 3/8

BGM-03-3080

BGM-03X-20

Rc 1/2

BGM-03X-3080

BGM-06-20

Rc 3/4

BGM-06-3080

BGM-06X-20

EBG-10

European Design Standard

Rc 1

Sub-plate
Model Numbers

Thread
Size

Approx.
Mass
kg (lbs)

3/8 BSP.F

BGM-03-2090

3/8 NPT

2.4 (5.3)

1/2 BSP.F

BGM-03X-2090

1/2 NPT

3.1 (6.8)

3/4 BSP.F

BGM-06-2090

3/4 NPT

4.7 (10.4)

1 NPT

5.7 (12.6)

Thread
Size

BGM-06X-3080

N. American Design Standard

1 BSP.F

BGM-06X-2090

BGM-10-20

Rc 1-1/4

BGM-10-3080

1-1/4 BSP.F

BGM-10-2090

1-1/4 NPT

8.4 (18.5)

BGM-10X-20

Rc 1-1/2

BGM-10X-3080

1-1/2 BSP.F

BGM-10X-2090

1-1/2 NPT

10.3 (22.7)

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used,
the mounting surface should have a good machined finish.

Instructions
Safety Valve
The pressure of the safety valve for EBG-03 is preset at the value equal to the upper limit of the pressure adjustment
range plus 2 MPa (290 PSI) subject to a flow rate of 50 L /min (13.2 U.S.GPM).
The same for EBG-06 is preset at the value equal to the upper limit of the pressure adjustment range plus 3.5 MPa (510
PSI) subject to a flow rate of 100 L /min (26.4 U.S.GPM).
The same for EBG-10 is preset at the value equal to the upper limit of the pressure adjustment range plus 4 MPa (580
PSI) subject to a flow rate of 200 L /min (52.8 U.S.GPM).
In case where the upper limit of operating pressure is low or the upper limit of flow rate to be used is different from the
specified maximum flow, please adjust and determine the setting pressure of the safety valve at the value calculated
from the following formula.
Setting pressure = (Operating pressure upper limit) + (Additional pressure indicated blow)

300

EBG-03
PSI

200
1
100
0

0
0 25

50

75 100 L /min

700
600
400

MPa
5

EBG-06

4
3
2

200
0

1
0
0 50 100 150 200 L /min

Additional Pressure

400

MPa
3

Additional Pressure

Additional Pressure

PSI

PSI
900
800

MPa
6

600

400

5 10 15 20 25 U.S.GPM
Flow Rate

0 10 20 30 40 50 U.S.GPM
Flow Rate

2
200
0

EBG-10

1
0
0 100 200 300 400 L /min
0 20 40 60 80 100 U.S.GPM
Flow Rate

To lower the setting pressure, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure
to tighten the lock nut.

No.12

E Series
Relief Valves
EBG-03/06

PROPORTIONAL
CONTROLS

Installation Drawing
Mounting Surface
EBG-03 : ISO 6264-AR-06-2-A
EBG-06 : ISO 6264-AS-08-2-A

EBG- 03
06 --51/5190
With Safety Valve
Fully Extended 216(8.50)

Lock Nut
10(.39) Hex.

DIMENSIONS IN
MILLIMETRES (INCHES)

Pressure Adj. Screw


for Safety Valve
3(.12) Hex.Soc.

EBG- 03
06 --T-51/5190

INC.

Without Safety Valve

"Q" Dia. Through


"S" Dia. Spotface
4 Places

A
B

For other dimensions, refer to the without safety valve.

C
D

The direction can be altered


to every 90 degree angles.

39
(1.54)

Tank Port "T"


Pressure Port "P"

This port is not used. It is provided


because of the common use of the body
with the low-noise relief valve.
On the sub-plate, plug the port which
corresponds to this port.

Connector
The direction can be altered
to every 90 degree angles.
Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

48
(1.89)

Air Vent 3(.12) Hex. Soc.


3 Places

199.5
(7.85)

57.5
(2.26)

27.5
(1.08)

130
(5.12)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

6
(.24)

INC.

Mounting Surface
(O-Rings Furnished)

N
L

6 (.24) Dia.
Locating Pin

Model Numbers

Dimensions

mm (Inches)

EBG-03

197.5
(7.78)

117.6
(4.63)

53.8
(2.12)

40.3
(1.59)

76
(2.99)

53.8
(2.12)

26.9
(1.06)

11.1
(.44)

21.5
(.85)

106
(4.17)

26.1
(1.03)

13.5
(.53)

21
(.83)

EBG-06

205.5
(8.09)

119.5
(4.70)

66.7
(2.63)

42.2
(1.66)

98
(3.86)

70
(2.76)

35
(1.38)

14
(.55)

26
(1.02)

122
(4.80)

36
(1.42)

17.5
(.69)

26
(1.02)

No.13

E Series
Relief Valves
EBG-10

PROPORTIONAL
CONTROLS

Installation Drawing
Mounting surface:
ISO 6264-AT-10-2-A

EBG-10--51/5190
With Safety Valve
Fully Extended 216(8.50)

DIMENSIONS IN
MILLIMETRES (INCHES)

Lock Nut
10(.39) Hex.
Pressure Adj. Screw
for Safety Valve
3(.12) Hex.Soc.

EBG-10--T-51/5190

INC.

Without Safety Valve

101
(3.98)
39
(1.54)

41.3
(1.63)
82.6
(3.25)
120
(4.72)

For other dimensions, refer to the without safety valve.

88.9
(3.50)
23.7
(.93)

21.5(.85) Dia. Through


32(1.26) Dia. Spotface
4 Places
18.7
(.74)

211(8.31)

The direction can be altered


to every 90 degree angles.

Tank Port "T"


Pressure Port "P"

This port is not used. It is provided


because of the common use of the body
with the low-noise relief valve.
On the sub-plate, plug the port which
corresponds to this port.

Connector
The direction can be altered
to every 90 degree angles.
Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

48
(1.89)
27.5
(1.08)

235.5(9.27)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.
INC.

Mounting Surface
(O-Rings Furnished)

6
(.24)

33.5
(1.32)

166(6.54)

57.5
(2.26)

Air Vent
3(.12) Hex.Soc.
3 Places

6 (.24) Dia.
Locating Pin

No.14

45
(1.77)
155
(6.10)

E Series
Sub-plate for Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing
BGM-03,03X-20/3080/2090
Sub-plate: BGM-06,06X-20/3080/2090
BGM-10,10X-20/3080/2090

DIMENSIONS IN
MILLIMETRES (INCHES)
A

"d" Dia. Through


"e" Dia. Spotface
4 Places
"h"
4 Places

"t" Thd.
(From Rear)

S
Q

H
K

6.2(.24) Dia.

"b" Dia.
2 Places
7(.28) Dia.
10(.39) Deep

Model Numbers

"n" Thd.
2 Places
(From Rear)

Dimensions mm (Inches)
D

13
60
86
(3.39) (2.36) (.51)

53.8
(2.12)

3.1
(.12)

13
149
26.9
(1.06) (5.87) (.51)

BGM-06
BGM-06X

15
78
108
(4.25) (3.07) (.59)

70
(2.76)

4
(.16)

15
180
35
(1.38) (7.09) (.59)

BGM-10
BGM-10X

16
94
126
(4.96) (3.70) (.63)

82.6
(3.25)

5.7
(.22)

16
227
41.3
(1.63) (8.94) (.63)

BGM-03
BGM-03X

Model Numbers
BGM-03
BGM-03X
BGM-06

BGM-10
BGM-10X

BGM-03
BGM-03X
BGM-06
BGM-06X
BGM-10
BGM-10X

86
123 (3.39) 32
(4.84) 95 (1.26)
(3.74)
106.5
150 (4.19) 51
(5.91) 119 (2.01)
(4.69)
138.2
195 (5.44) 62
(7.68) 158 (2.44)
(6.22)

26
(1.02) 97
53.8
21 (3.82) (2.12)
(.83)
27.2
(1.07) 121
66.7
18 (4.76) (2.63)
(.71)
30.2
(1.19) 154
88.9
17 (6.06) (3.50)
(.67)

Dimensions mm (Inches)
T

19
(.75)

47.4
(1.87)

0
(0)

22
(.87)

22
(.87)

33.4
(1.31)

11
(.43)

42
76.2 31.8 44.5
(1.65) (3.00) (1.25) (1.75)

12.7
(.50)

37
55.5 23.8
(1.46) (2.19) (.94)

BGM-06X

Model
Numbers

Japanese Standard "JIS"


Design "20"
"h"

"n" Thd.

M12 Thd.
20(.79) Deep

Rc 3/8

M16 Thd.
25(.98) Deep

Rc 3/4

M20 Thd.
28(1.10) Deep

Rc1-1/4
Rc 1-1/2

32
(1.26) 20
14.5
11
(.79) (.57) (.43)
40
(1.57)
40
(1.57) 25
23
13.5
(.98) (.91) (.53)
50
(1.97)
50
(1.97) 32
28
17.5
63 (1.26) (1.10) (.69)
(2.48)

17.5
(.69)

19
(.75)

21
(.83)

24
(.94)

26
31
(1.02) (1.22)

European Design Standard


Design "3080"
"t" Thd.

Rc 1/2

Rc 1

Rc 1/4

"h"

"n" Thd.

M12 Thd.
20(.79) Deep

3/8 BSP.F

M16 Thd.
25(.98) Deep

3/4 BSP. F

"t" Thd.

1-1/4 BSP.F
M20 Thd.
28(1.10) Deep 1-1/2 BSP.F

"h"

"n" Thd.

"t" Thd.

1/2-13UNC Thd. 3/8 NPT


22(.87) Deep
1/2 NPT

1/2 BSP.F

1 BSP.F

N. American Design Standard


Design "2090"

1/4 BSP.F

5/8-11UNC Thd. 3/4 NPT


27(1.06) Deep
1 NPT

1/4 NPT

3/4-10UNC Thd. 1-1/4 NPT


28(1.10) Deep
1-1/2 NPT

No.15

E SERIES
Relief Valves
EBG-03/0610

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Min. Adjustment Pressure
Viscosity : 30 mm2/s (141 SSU)
PSI

1.6
200
1.2
150
0.8

100
50

0.4

0
0

25

50

10

15

75

100
L /min

20

25
U.S.GPM

275
250

EBG-06

MPa
2.0

PSI

Min. Adjustment Pressure

275
250

EBG-03

MPa
2.0

Min. Adjustment Pressure

Min. Adjustment Pressure

PSI

1.6
200
1.2
150
100
50
0

Flow Rate

0.8
0.4
0
0

50

10

100

20

150

30

40

200
L /min
50
U.S.GPM

275
250

EBG-10

MPa
2.0
1.6

200
1.2
150
100

0.8

50

0.4

0
0

100

20

Flow Rate

200

40

60

300

80

400
L /min
100
U.S.GPM

Flow Rate

Step Response (Example)


These Characteristics have been obtained by measuring on each valve.
Therefore, they may vary according to a hydraulic circuit to be used.
PSI
2750
2500

MPa
20

EBG-03-C

PSI

0.2s

1500
8
1000

Pressure

Pressure

12

3000
2000
1000

EBG-06-C

PSI

0.2s

1500
8

3000

20

2000

15

EBG-06-H

0.2s

Step Signal

10
1000

Step Signal

Time
(Flow Rate : 200 L /min, 52.8 U.S.GPM)

Time
(Flow Rate : 200 L /min, 52.8 U.S.GPM)

MPa
20

EBG-10-C
PSI

MPa
30

EBG-10-H

4000
25

2000
12
1500

0.2s

Pressure

16
Pressure

MPa
30
25

Pressure

Pressure

12

1000

3000

Step Signal

15
10

1000
Time
(Flow Rate : 400 L /min, 106 U.S.GPM)

20
0.2s

2000

No.16

4000

2000

1000

Step Signal

Time
(Flow Rate : 100 L /min, 26.4 U.S.GPM)

16

2750
2500

15
10

Time
(Flow Rate : 100 L /min, 26.4 U.S.GPM)

MPa
20

20
0.2s

Step Signal

PSI

EBG-03-H

25

2000

PSI

MPa
30

4000
16

2750
2500

Trapped Oil Volume : 1 L (.264 U.S. Gallons)


Viscosity
: 30 mm2/s (141 SSU)

Step Signal

5
Time
(Flow Rate : 400 L /min, 106 U.S.GPM)

E SERIES
Relief Valves
EBG-03/06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Input Current vs. Pressure

Frequency Response
Trapped Oil Volume : 1 L (.264 U.S. Gallons)
Viscocity
: 30 mm2/s (141 SSU)

EBG-03
PSI
3500

MPa

EBG-03

25

Frequency (Hz)
20
EBG-03-H
Phase (deg.)

Pressure

2500
15
2000
1500

10

1000

EBG-03-C

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

7 10

20

-10
-20
-30

40

Gain
Phase

: 7.8 1.6 MPa


(1130 230 PSI)
Flow Rate : 100 L /min
(26.4 U.S.GPM)
Pressure

500
0

0.4 0.7 1

Gain (dB)

3000

0.2

0
0

200

400

600

800

1000

Input Current mA

EBG-06
3500
3500

MPa

EBG-06

25
0.2
20
EBG-06-H
Phase (deg.)

Pressure

2500
15
2000
1500

10

1000

EBG-06-C

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

0.4

7 10

20

-10
-20
-30

40

Gain
Phase

: 7.8 1.6 MPa


(1130 230 PSI)
Flow Rate : 200 L /min
(52.8 U.S.GPM)
Pressure

500
0

Frequency (Hz)
0.71
2
4

Gain (dB)

PSI

0
0

200

400

600

800

1000

Input Current mA

EBG-10
PSI

MPa

3500

25

EBG-10
Frequency (Hz)
0.2

20
EBG-10-H
15

Phase (deg.)

Pressure

2500
2000
1500

10

1000
EBG-10-C

5
500
0

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

0.4 0.7 1

-10
-20
-30
Gain (dB)

3500

7 10

20

Gain
Phase

: 7.8 1.6MPa
(1130 230 PSI)
Flow Rate : 400 L /min
(106 U.S.GPM)
Pressure

0
0

200

400

600

800

1000

Input Current mA

No.17

E SERIES
Relief Valves
EBG-03/06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Viscosity vs. Pressure

Flow Rate vs. Pressure

Oil : ISO VG 46 Oil

Viscosity : 30 mm2/s (141 SSU)

EBG-03
Flow Rate : 100 L /min
(26.4 U.S.GPM)
MPa

EBG-03-H

24.9
Pressure

3600
3500
2350
2300
2250

EBG-03

24.5
24.1
EBG-03-C
16.1
15.7
15.3
30

35

Pressure

PSI

40

45

50

55

60

140
20

F
mm2/s

PSI

MPa

3600
3450
3300
2300
2150
2000

24.5
23.5
22.5
15.7
14.7
13.7

Temperature
90
70 60

100
50

120
30

40

25

Viscosity

0
300 250

200

150

125

25

50

10

SSU

100

15
Flow Rate

75

100 L /min

20

25 U.S.GPM

150

200 L /min

EBG-06
Flow Rate : 200 L /min
(52.8 U.S.GPM)
MPa

Pressure

3600
3500
2350
2300
2250

EBG-06

EBG-06-H

24.9

24.5
24.1
EBG-06-C
16.1
15.7
15.3
30

35

Pressure

PSI

40

45

50

55

60

140
20

F
mm2/s

PSI

MPa

3600
3400
3200
2300
2150
2000

24.5
23.0
21.5
15.7
14.7
13.7

Temperature
90
70 60

100
50

120
30

40

25

Viscosity

0
300 250

200

150

125

50

10

SSU

100

100

20

30
Flow Rate

40

50

U.S.GPM

EBG-10
Flow Rate : 400 L /min
(106 U.S.GPM)

Pressure

3600
3500
2350
2300
2250

EBG-10

MPa EBG-10-H
24.9
24.5
24.1
EBG-10-C
16.1
15.7
15.3
30

35

Pressure

PSI

40

45

50

55

60

140
20

F
mm2/s

PSI

MPa

3500
3250
3000
2250
2000
1750

24.5
22.5
20.5
15.7
13.7
11.7

Temperature
90
70 60

100
50

40

120
30

25

Viscosity

0
300 250

No.18

200

150

125

100

SSU

100

200

300

20

50
75
Flow Rate

400 L /min

100 U.S.GPM

E Series
Relief Valves
EBG-03/06/10

PROPORTIONAL
CONTROLS

Spare Parts List


03
EBG- 06 ---51/5190
10

17

23 19 10
Pilot Valve

18
2
11
19

22

14

12

15
13

21

16

Valve Model Numbers

10 Pilot Valve Model Numbers

EBG-03-C-51/5190
EBG-03-H-51/5190
EBG-03-C-T-51/5190
EBG-03-H-T-51/5190
EBG-06-C-51/5190
EBG-06-H-51/5190
EBG-06-C-T-51/5190
EBG-06-H-T-51/5190
EBG-10-C-51/5190
EBG-10-H-51/5190
EBG-10-C-T-51/5190
EBG-10-H-T-51/5190

EDG-01V-C-1-PNT09-51
EDG-01V-H-1-PNT09-51
EDG-01V-C-PNT09-51
EDG-01V-H-PNT09-51
EDG-01V-C-1-PNT10-51
EDG-01V-H-1-PNT10-51
EDG-01V-C-PNT10-51
EDG-01V-H-PNT10-51
EDG-01V-C-1-PNT11-5103
EDG-01V-H-1-PNT11-5103
EDG-01V-C-PNT11-5103
EDG-01V-H-PNT11-5103

Note: For the details of pilot valves, refer to "Pilot Relief Valves"
on page 9.

List of Seals
Item

Name of Parts

11
12
13
14
15
16

O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

EBG-03
SO-NB-P32
SO-NB-P28
SO-NB-P9
SO-NB-P9
SO-NB-A024
SO-NB-P18

Part Numbers
EBG-06
SO-NB-P32
SO-NB-P28
SO-NB-P11
SO-NB-P9
SO-NB-A024
SO-NB-P28

EBG-10
SO-NB-P42
SO-NB-P28
SO-NB-P9
SO-NB-P9
SO-NB-A128
SO-NB-P32

Qty.
1
1
1
2
1
2

Note) When ordering seals, please specify the seal kit number from the table below.
In addition to the above O-rings, O-rings for pilot valve are included in the seal kit.
For the details of the pilot valve seals, see page 9.

List of Seal Kit


Model Numbers

Seal Kit Numbers

EBG-03
EBG-06
EBG-10

KS-EBG-03-51
KS-EBG-06-51
KS-EBG-10-51

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

No.19

E Series
Relief Valves
EBG-03/06/10

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
EBG-03/06/10 series valves have changed model from 50 to 51 design in line with the model change of pilot valve
(EDG-01).
Specifications and Characteristics
No change in specifications and characteristics between current and new design.
Mounting Interchangeability
There is an interchangeability in the mounting dimensions, however, the outside shape and dimensions are changed as
shown below due to pilot valve improvement and other modifications.

Current: Design 50

New: Design 51

Fully Extended A

Fully Extended A

B
C

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

Adaptor 22(.87) Hex.


Air Vent
3(.12) Hex. Soc.
3 Places

Air Vent
3(.12) Hex. Soc.
Pilot Valve
EDG-01V, 50Design

Pilot Valve
EDG-01V, 51Design
Manual Pressure
Adj. Screw
for Safety Valve
3(.12) Hex.Soc.

Manual Pressure
Adj. Screw
for Safety Valve
3(.12) Hex.Soc.

See EDG-01 (page 9) for


details of the solenoid ass'y

Model Numbers

No.20

See EDG-01 (page 9) for


details of the solenoid ass'y

118.6
(4.67)

40.2
(1.58)

Current

EBG-03---50/5090

217
(8.54)

New

EBG-03---51/5190

216
(8.50)

117.6
(4.63)

40.3
(1.59)

Current

EBG-06---50/5090

217
(8.54)

120.5
(4.74)

42.1
(1.66)

New

EBG-06---51/5190

216
(8.50)

119.5
(4.70)

42.2
(1.66)

Current

EBG-10---50/5090

217
(8.54)

102
(4.02)

23.6
(.93)

New

EBG-10---51/5190

216
(8.50)

101
(3.98)

23.7
(.93)

199.5
(7.85)

130
(5.12)

199.5
(7.85)

130
(5.12)

235.5
(9.27)

166
(6.54)

DIMENSIONS IN
MILLIMETRES (INCHES)

E Series
Reducing & Relieving Valves
ERBG-06/10 (3/4, 1-1/4)
Sub-plate Mounting

PROPORTIONAL
CONTROLS

Specifications / Model Number Designation


Specifications
Model Numbers

ERBG-06

ERBG-10

24.5 (3550)

24.5 (3550)

100 (26.4)

250 (66)

35 (9.24)

15 (3.96)

Description
Max. Operating Pres.
MPa (PSI)
Max. Flow
L /min(U.S.GPM)
Max. Relieving Flow
L /min(U.S.GPM)
Secondary Pres. Adj. Range
MPa (PSI)

Refer to Model Number Designation


B : 800 mA
C : 800 mA
H : 950 mA

B : 800 mA
C : 800 mA
H : 950 mA

10

10

Hysteresis

Less than 3%

Less than 3%

Repeatability

Less than 1%

Less than 1%

12 (26.5)

13.5 (29.8)

Rated Current
Coil Resistance

Approx. Mass

kg (lbs.)

The values shown are those obtained where the differential pressure between the
secondary pressure port and tank port is 13.7 MPa (2000 PSI).

H
Graphic Symbol

Model Number Designation

ERB

-06

-C

-51

Series Number

Type of
Mounting

Valve
Size

Secondary Pres. Adj. Range


MPa (PSI)

Design
Number

Design
Standards

06

B: 0.8 - 6.9 (115 - 1000)


C: 1.2 - 13.7 (175 - 2000)
H: 1.5 - 20.6 (220 - 3000)

10

B: 0.9 - 6.9 (130 - 1000)


C: 1.2 - 13.7 (175 - 2000)
H: 1.5 - 20.6 (220 - 3000)

ERB :
Proportional
Electro-Hydraulic
Reducing and
Relieving Valve

G:
Sub-plate
Mounting

51

Refer to

Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

No.21

E Series
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Sub-plate / Instructions / Others


Attachment
Mounting Bolts
Socket Head Cap Screw

Valve
Model Numbers

Japanese Standard "JIS" & European Design Standard

N. American Design Standard

Qty.

ERBG-06

M10 70 Lg.

3/8 - 16 UNC 2-3/4 Lg.

ERBG-10

M10 70 Lg.

3/8 - 16 UNC 2-3/4 Lg.

Applicable Power Amplifier


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
Catalogue No. Pub. EC-1305).
Model Numbers: AME-D-10--20
AME-D2-1010--10
SK1022---11
SK1015-11 (For DC power supply)
AMN-D-10 (For DC power supply)

Sub-plate
Japanese Standard "JIS"

Valve
Model
Numbers

Sub-plate
Model Numbers

ERBG-06
ERBG-10

European Design Standard

Thread
Size

Sub-plate
Model Numbers

ERBGM-06-20

Rc 3/4

ERBGM-10-10

Rc 1-1/4

N. American Design Standard


Thread
Size

Approx.
Mass
kg (lbs.)

Thread
Size

Sub-plate
Model Numbers

ERBGM-06-2080

3/4 BSP.F

ERBGM-06-2090

3/4 NPT

3.0 (6.6)

ERBGM-10-1080

1-1/4 BSP.F

ERBGM-10-1090

1-1/4 NPT

6.5 (14.3)

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the
mounting surface should have a good machined finish.

Instructions
Primary Pressure Required for Preselected Pressure
The primary pressure must be 1 MPa (145 PSI) higher than the preselected pressure.
Drain Back Pressure
Check that the drain back pressure does not exceed 0.2 MPa (29 PSI).
Trapped Oil Volume
The recommended secondary side trapped oil volume is about 20 liters (5.28 U.S.Gallons). Note that the trapped oil
volume must not be lower than 1.4 liters (.37 U.S.Gallons).

No.22

E Series
Reducing & Relieving Valves
ERBG-06

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-plate:
ERBGM-06-20/2080/2090
130(5.12)
30.7 77.3(3.04)
(1.21) 60.3(2.37)

"E" Thd.
20(.79) Deep
4 Places

49.2(1.94)
44.5(1.75)

DIMENSIONS IN
MILLIMETRES (INCHES)

20.6(.81)

25
(.98)

11.1
(.44)

79.4
(3.13)
73
(2.87)
39.7
(1.56)

12.3
(.48)

5(.20) Dia.

79.4
(3.13)

104(4.09)

213.5(8.41)
2
(.08)

7(.28) Dia.
10(.39) Deep

104(4.09)

16
(.63)

27.9
(1.10)

75.2
(2.96)

60.3
(2.37)

Tank Port "T"

136(5.35)

15(.59)

"D" Thd.
(From Rear)

45(1.77)

18(.71) Dia.
2 Places

The direction can be alterd


to every 90 degree angles.

"C" Thd.
(From Rear)

20.7
(.81)

"B" Thd.
2 Places
(From Rear)

ERBG-06--51/5190

10(.39) Dia.

16(.63)

102
(4.02)

11.3
(.44)

8.8(.35) Dia. Through


14(.55) Dia. Spotface
4 Places

Primary Pressure Port "P"

Sub-plate
Model Numbers
ERBGM-06-20
ERBGM-06-2080
ERBGM-06-2090

Drain
Port "DR"

Thread Size
"B" Thd. "C" Thd. "D" Thd. "E" Thd.
Rc 1/4
Rc 3/8
Rc 3/4
M10
3/4 BSP.F 3/8 BSP.F 1/4 BSP.F
3/4 NPT 3/8 NPT 1/4 NPT 3/8-16 UNC

48
(1.89)

39
(1.54)

27.5
(1.08)

6
(.24)

184.5(7.26)

115
(4.53)
90
(3.54)
56
(2.20)

57
(2.24)

INC.

136.5
(5.37)

57.5
(2.26)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

6 (.24) Dia.
Locating Pin

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2 (.002 sq. in.)

Connector
The direction can be altered
to every 90 degree angles.

Air Vent
3(.12) Hex. Soc.
3 Places

Secondary Pressure
Port "A"

69.7
(2.74)

208
(8.19)
Mounting Surface
(O-Rings Furnished)

No.23

E Series
Reducing & Relieving Valves
ERBG-10

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-plate:
ERBGM-10-10/1080/1090
101.5(4.00)
84.1(3.31)
67.5(2.66)

42.1(1.66)

12
(.47)

96
(3.78)

234.5(9.23)
63.5
(2.50)

28(1.10) Dia.
2 Places

126(4.96)

11.1
(.44)

12
(.47)

The direction can be alterd


to every 90 degree angles.

"B" Thd.
2 Places
(From Rear)

30(1.18)

"D" Thd.
(From Rear)

ERBG-10--51/5190

7(.28) Dia.
10(.39) Deep

150(5.91)

119(4.69)

Thread Size
"B" Thd. "C" Thd. "D" Thd. "E" Thd.
Rc 1/4
Rc 3/8
Rc 1-1/4
ERBGM-10-10
M10
ERBGM-10-1080 1-1/4 BSP.F 3/8 BSP.F 1/4 BSP.F
ERBGM-10-1090 1-1/4 NPT 3/8 NPT 1/4 NPT 3/8-16 UNC
Sub-plate
Model Numbers

Drain Port "DR"

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2 (.002 sq. in.)

48
(1.89)
27.5
(1.08)

39
(1.54)

6
(.24)

186.5(7.34)

117
(4.61)
92
(3.62)
55
(2.17)

56
(2.20)

INC.

158
(6.22)

57.5
(2.26)

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

6 (.24) Dia.
Locating Pin

11(.43) Dia.
Through
17.5(.69) Dia.
Spotface
6 Places

Primary
Pressure Port "P"

Connector
The direction can be altered
to every 90 degree angles.

Air Vent
3(.12) Hex. Soc.
3 Places

Tank Port "T"

Secondary
Pressure Port "A"

2
(.08)

55(2.17)

20(.79)

19(.75)

5(.20) Dia.

84.1
(3.31)
42.1
(1.66)

96.8
(3.81)

27
(1.06)

21
(.83)

DIMENSIONS IN
MILLIMETRES (INCHES)
140(5.51)

16.7
(.66)

14(.55) Dia.
9.6
(.38)

25
(.98)

24.6
(.97)

96.8
(3.81)
92.9
(3.66)
48.4
(1.91)

11.6
(.46)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

120(4.72)

"C" Thd.
(From Rear)

62.7(2.47)

116(4.57)

"E" Thd.
20(.79) Deep
6 Places

62
(2.44)

233
(9.17)
Mounting Surface
(O-Rings Furnished)

No.24

E SERIES
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Step Response (Example)
The following step response characteristics are taken when the trapped oil volume is 20 liters (5.28 U.S.Gallons).
The step response varies by trapped oil volume.
: 24.5 MPa (3550 PSI)
Primary Pressure
Trapped Oil Volume : 20 L (5.28 U.S.Gallons)
: 30 mm2/s (141 SSU)
Viscocity

ERBG-06-B
1200

7.8

1000

Secondary Pressure

Secondary Pressure

ERBG-10-B

MPa
8.8

PSI

5.9

800

0.1s
600

3.9

400
2.0

Step Signal

PSI
1400

MPa
9.8

1200

7.8

1000
800

5.9
0.1s

600

3.9

400
2.0

200

Step Signal

200
0

Time

Time

ERBG-06-C
PSI
3000

ERBG-10-C
PSI

MPa
21.6
19.6

2750
2500

2000
11.8
1500

0.1s
7.8
3.9

Step Signal

Secondary Pressure

Secondary Pressure

15.7

500

2000
11.8
1500
1000
500

0.1s
7.8
3.9

Step Signal

Time

Time

ERBG-10-H

ERBG-06-H

Secondary Pressure

3000

MPa
23.5
19.6
15.7
0.1s

2000
11.8
1500
1000
500
0

7.8
3.9

PSI
4000

MPa
27.5

3500

23.5

3000

2500

Step Signal

Secondary Pressure

PSI
3500

15.7

2500

1000

MPa
19.6

2500

1500
1000

0
Time

15.7
0.1s

2000

500

19.6

11.8
7.8

Step Signal

3.9
0
Time

No.25

E SERIES
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Input Current vs. Secondary Pressure
Primary Pressure : 24.5 MPa (3550 PSI)
Viscocity
: 30 mm2/s (141 SSU)

ERBG-10

MPa
21.0

PSI
3000

MPa
21.0

2500

17.5

2500

17.5

2000

14.0

1500

10.5

1000

7.0

500

3.5

2000

14.0

1500

10.5

Secondary Pressure

Secondary Pressure

ERBG-06
PSI
3000

ERBG-06-H

ERBG-06-C
1000

7.0

500

3.5

ERBG-06-B

ERBG-10-H

ERBG-10-C

ERBG-10-B
0

200

400

600

800

1000

Input Current mA

200

400

600

800

1000

Input Current mA

Frequency Response

No.26

7 10

Gain (dB)

Gain
Phase
Secondary Pressure
4.9 1.5 MPa
(710 215 PSI)

0.1

0.2

0.4 0.71

Phase

ERBG-10-C

0.4 0.7 1

7 10

Gain

Phase

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

10
0
-10
-20

0.1

0.2

0.4 0.71

ERBG-10-H
Frequency (Hz)

0.4 0.7 1

7 10

Gain
Phase
Secondary Pressure
16.7 3.9 MPa
(2420 565 PSI)

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

7 10

Phase

Frequency (Hz)
0.2

Secondary Pressure
10.8 2.9 MPa
(1565 420 PSI)

ERBG-06-H
0.1

Gain

Gain (dB)

0.2

7 10

Secondary Pressure
4.9 1.5 MPa
(710 215 PSI)

Frequency (Hz)

0.1

Gain

ERBG-06-C

Secondary Pressure
10.8 2.9 MPa
(1565 420 PSI)

10
0
-10
-20

10
0
-10
-20

Frequency (Hz)

Phase (deg.)

10
0
-10
-20

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

Gain (dB)

0.4 0.7 1

Phase (deg.)

0.2

10
0
-10
-20

0.1

0.2

0.4 0.7 1

7 10

Gain

Gain (dB)

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

0.1

Phase (deg.)

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

10
0
-10
-20

ERBG-10-B
Frequency (Hz)

Gain (dB)

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

ERBG-06-B
Frequency (Hz)

Gain (dB)

Phase (deg.)

Phase (deg.)

Phase (deg.)

: 24.5 MPa (3550 PSI)


Primary Pressure
Trapped Oil Volume : 20 L (5.28 U.S.Gallons)
: 30 mm2/s (141 SSU)
Viscocity

Phase
Secondary Pressure
16.7 3.9 MPa
(2420 565 PSI)

E SERIES
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Flow Rate vs. Secondary Pressure

Viscosity : 30 mm2/s (141 SSU)

1000
900
700
600

4.9
4.4
3.9

500
400

3.4
2.9
2.4

100
0

1.0
0.5
0

Secondary Pressure

ERBG-10-B

Secondary Press.

ERBG-06-B
MPa
6.9
6.4
5.9

PSI

PSI
1000
800

MPa
6.9
5.9
4.9

600
400

3.9
2.9
1.9

200
0

2.0
1.0
0
0

20

40

60

80

25

100 L /min

50
10

75 100 125 150 175 200 225 250 L /min


20

30

40

50

60 65 U.S.GPM

Flow Rate
0

10

15

20

25

U.S.GPM

Flow Rate

ERBG-06-C

Secondary Pressure

1900

ERBG-10-C

MPa
13.7
13.2
12.7

1400
1300

9.8
9.3
8.8

1000
900

6.9
6.4
5.9

600
500
400

3.9
3.4
2.9

Secondary Press.

PSI
2000

PSI
1600
1400

MPa
10.8
9.8
8.8

800
600

5.9
4.9
3.9
0 25
0

50
10

75 100 125 150 175 200 225 250 L /min


20

30

40

50

60 65 U.S.GPM

Flow Rate
0
0

20
5

40
10

60
15

80
20

100 L /min
25

U.S.GPM

Flow Rate

MPa
20.6
19.6
18.6

2000
1800

13.7
12.7
11.7

1400
1200

9.8
8.8
7.8

1000
900

6.9
6.4
5.9

ERBG-10-H

Secondary Pressure

Secondary Pressure

ERBG-06-H
PSI
3000
2800

0
0

20
5

40
10

60
15

Flow Rate

80
20

100 L /min
25

U.S.GPM

PSI
3200
2800

MPa
21.6
19.6
17.6

2400
2000

16.7
14.7
12.7

1600
1200

11.8
9.8
7.8

1000
800

6.9
4.9
2.9
0 25
0

50
10

75 100 125 150 175 200 225 250 L /min


20

30

40

50

60 65 U.S.GPM

Flow Rate

No.27

E SERIES
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Viscosity vs. Secondary Pressure

ERBG-06-B

525
500
475

3.7
3.5
3.2

Secondary Pressure

Oil: ISO VG 32 Oil

Oil: ISO VG 56 Oil


Secondary Pressure

1025
1000
975

MPa
7.1
6.9
6.6

PSI

ERBG-10-B

20

30

40

50

60

Temperature
70
70

Viscosity

80
50

300

100
40
30

120
20

150

100

200

80

MPa
7.4
6.9
6.4

550
500
450

3.9
3.4
2.9
20

30

40

50

70 80
100
150 100 75 60 50

120
40

500

SSU

300

200

7.4
6.9
6.4
20

30

40

PSI
2000
1900

MPa
13.7
13.2
12.7

1050
1000
950

7.4
6.9
6.4
20

60

50

50 60
300 200

80
100 75

100
60 50

120
40

30

30

40

50

70 80
100
150 100 75 60 50

140 F
2
25 mm /s

Viscosity
500

300

150

200

500

SSU

300

ERBG-06-H

120
40
200

70

30

140
25

20

160 F
mm2/s

100

SSU

ERBG-10-H
Oil: ISO VG 56 Oil

MPa
20.6
19.6
18.6

Secondary Pressure

Secondary Pressure

1400

SSU

60

150

Oil: ISO VG 56 Oil

1600

100

Viscosity
1000

2800

160 F
mm2/s

Temperature

Temperature

PSI
3000

20

Oil: ISO VG 56 Oil

MPa
13.7
13.2
12.7

10

140
25

ERBG-10-C

Secondary Pressure

Secondary Pressure

1050
1000
950

30
150

Oil: ISO VG 56 Oil

1900

Viscosity

ERBG-06-C
PSI
2000

70

60

Temperature

F
140
2
15 mm /s
90

PSI
1050
1000
950

10.8
9.8
8.8
10

20

30

40

50

60

PSI
3000
2800

MPa
20.6
19.6
18.6

1600
1400

10.8
9.8
8.8
20

30

40

50

60

70

Temperature
Temperature 50 60
300 200

80
100 75

100
60 50

120
40

30

140 F
2
25 mm /s

120
40

30

140
25

20

160 F
mm2/s

100

SSU

Viscosity

Viscosity
1000

No.28

70 80
100
150 100 75 60 50

500

300

200

150

SSU

500

300

200

150

E Series
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Spare Parts List


Spare Parts List
ERBG- 06
10 --51/5190

13
11
16

1 17 11

List of Seals
Item

Name of Parts

8
9
10
11

O-Ring
O-Ring
O-Ring
O-Ring

6 18

9 14 10 2 15 12

Pilot Valve
Part Numbers
ERBG-06
ERBG-10
SO-NB-P36
SO-NB-G30
SO-NB-P32
SO-NB-P28
SO-NB-P18
SO-NB-P14
SO-NB-P9
SO-NB-P9

Qty.
2
2
1
3

Note) When ordering seals, please specify the seal kit number from
the table right. In addition to the above O-rings, O-rings for pilot
valve are included in the seal kit.
For the details of the pilot valve seals, see page 9.

List of Seal Kits


Model Numbers

Seal Kit Numbers

ERBG-06
ERBG-10

KS-ERBG-06-51
KS-ERBG-10-51

Valve Model No.


ERBG-06-B-51/5190
ERBG-06-C-51/5190
ERBG-06-H-51/5190
ERBG-10-B-51/5190
ERBG-10-C-51/5190
ERBG-10-H-51/5190

7 Pilot Valve Model Numbers


EDG-01-B-PNTN-5101
EDG-01-C-PNTN-5101
EDG-01-H-PNT15-5101
EDG-01-B-PNTN-5101
EDG-01-C-PNTN-5101
EDG-01-H-PNT15-5101

Note: For the details of pilot valves, refer to "Pilot Relief Valves"
on page 9.

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

No.29

E Series
Reducing & Relieving Valves
ERBG-06/10

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
ERBG-06/10 series valves have changed model from 50 to 51 design in line with the model change of pilot valve
(EDG-01).
Specifications and Characteristics
No change in specifications and characteristics between current and new design.
Mounting Interchangeability
There is an interchangeability in the mounting dimensions, however, the outside shape and dimensions are changed as
shown below due to pilot valve improvement and other modifications.

Current: Design 50
See EDG-01 (page 8)
for details about the
solenoid ass'y

New: Design 51

Pilot Valve
EDG-01, 5001 Design

Air Vent
3(.12) Hex. Soc.

See EDG-01 (page 8)


for details about the
solenoid ass'y

A
Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

Adaptor
22(.87) Hex.

Model Numbers

Current ERBG-06--50/5090

214.5
(8.44)

136.5
(5.37)

115
(4.53)

ERBG-06--51/5190

213.5
(8.41)

136.5
(5.37)

115
(4.53)

Current ERBG-10--50/5090

235.5
(9.27)

158
(6.22)

117
(4.61)

ERBG-10--51/5190

234.5
(9.23)

158
(6.22)

117
(4.61)

New

No.30

Air Vent
3(.12) Hex. Soc.
3 Places

Manual Pressure
Adj. Screw
3(.12) Hex.Soc.

New

Pilot Valve
EDG-01, 5101 Design

DIMENSIONS IN
MILLIMETRES (INCHES)

Pub. EC-1303

E SERIES
PROPORTIONAL FLOW CONTROLS
Flow Control / Flow Control and Check /
Flow Control and Relief

PROPORTIONAL
CONTROLS

General Information
Up to 24.5 MPa (3550 PSI), 500 L/min (132 U.S.GPM)
Flow Control / Flow Control and Check Valves
These valves vary their output flow proportionally to an input current, therefore, by controlling the input current
from the power amplifier, the flow rate in the system can be continuously, remotely and optionally regulated.
Furthermore, as the valves have the functions of pressure and temperature compensation, the flow rate is not affected
by the variation in the pressure (load) and temperature (viscosity of hydraulic fluids).
These valves are optimal for such a usage where the start-up, stop and speed change of the actuator are required to be
done without shocks. The valves are used together with the applicable power amplifiers.

40 Series .............................................. Page 4

10 Series ............................................. Page 14

A direct-acting model designed to control the throttle


with a high-power solenoid is employed, providing a
high strength against contamination in oil and an outstanding reliability.

A hydraulic pilot amplification model is employed,


achieving a small hysteresis with a small solenoid.

O
M

O
M

H
Flow Control and Relief Valves
These valves control the pump pressure effectively by responding to a small pressure difference against the load
pressure. Therefore, it can be said that they are energy-saving metre-in type flow control valves which can be operated
at a low power consumption. Furthermore, as the valves have temperature compensator, the stable control of the flow
rate is possible irrespective of change in the oil temperature.

40 - 10 Series ...... Page 22

10 - 10 Series ...... Page 33

High Flow Series ....... Page 44

For flow control, a direct-acting


model using a high-power solenoid
is employed, providing an outstanding reliability.

For flow control, a hydraulic pilot


amplification model is employed,
providing a small hysteresis.

Parts have been improved, doubling


the maximum controlled flow,
which enables the equipment to be
compacted.

A
Y

A
Y

O
M

O
M

O
M

No.1

E SERIES
Flow Control Valves
Flow Control / Flow Control and Check /
Flow Control and Relief

PROPORTIONAL
CONTROLS

Hydraulic Fluids
Hydraulic Fluids
Fluid Types
Any type of hydraulic fluid listed in the table below can be used.
Petroleum Base Oils

Use fluids equivalent to ISO VG 32 or VG 46.

Synthetic Fluids

Use phosphate ester or polyol ester fluids. When phosphate ester fluid is used, prefix "F-" to the
model number because the special seals (fluororubber) are required to be used.

Water-Containing Fluids

Use water-glycol fluid.

Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

Recommended Fluid Viscosity and Temperature


Use hydraulic fluids which satisfy the both recommended viscosity and oil temperatures given in the table below.
Name

Viscosity

Temperature

Flow Control Valves


Flow Control and Check Valves
Flow Control and Relief Valves

20 - 200 mm2/s
(98 - 900 SSU)

-15 - +70C
(5 - 160F)

Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
11. Use 20 m or finer line filter.

No.2

E SERIES
Flow Control Valves

PROPORTIONAL
CONTROLS

Flow Control / Flow Control and Check /


Flow Control and Relief
Instructions
Mounting Positioning Orientation

Be sure that the air vent faces up. The air vent position can be changed as desired.
If the pressure control solenoid of the EFBG valve is mounted vertically, the minimum adjustment pressure is 2 MPa
(290 PSI) or higher.
[Good example]
[Bad example]
Air Vent
Air Vent

SOL

SOL

Air Vent
Air Vent

SOL

Air Vent

Air Vent

Air Bleeding

Manual Adjustment Screw

To ensure stable control, bleed the air from solenoid


completely and fill its iron core with oil.
Bleeding can be done by slowly loosening an air vent.
The 10 series solenoid has three air vents. Choose one
that appears most helpful (see the figure below).

When initial adjustments are to be made or when no


current is supplied to the valve due to electrical failure
or other problem, turn the manual adjustment screw to
temporarily set the valve pressure and flow rate. In that
case, when turn the manual adjustment screw clockwise,
the valve pressure rises and flow increase. Under normal conditions, however, this screw must be kept in its
original position (see the figure below).
Solenoid

Solenoid
Air Vent 3 Places

Case
Air Vent

Manual Pressure Adj. Screw or


Manual Flow Adj. Screw

10 Series Solenoid

M4 Screw

Manual adjustment pin


Manual adjustments can be done by screwing for
example an M4 20L screw in the M4 thread or
pushing in a pin there with a rod etc.

40 Series Solenoid

Tank and Drain Piping

Hysteresis and Repeatability Value Indications

The tank-line back pressure and drain back pressure


directly affect the minimum adjustment pressure or
flow adjustment valve main spool operating force.
Therefore, do not connect the tank or drain pipes to
other lines, but connect them directly to the reservoir
maintaining the back pressure as low as possible.
Be sure that the tank and drain pipe ends are immersed
in fluid.

The hysteresis and repeatability values indicated in the


specifications for each control valve are determined
under the following conditions:
Hysteresis Value: Obtained when Yuken's applicable power amplifier is used.
Repeatability Value: Obtained when Yuken's applicable power amplifier is used
under the same conditions.

No.3

E Series
40 Series Flow Control (and Check) Valves
PROPORTIONAL
EFG/EFCG-02/03/06/10 (1/4, 3/8, 3/4, 1-1/4)
CONTROLS
Sub-plate Mounting
Specifications / Model Number Designation

Specifications
Model No.
Description
Max. Operating Pres.
MPa (PSI)
Metred Flow
Adjustment Range
L /min (U.S.GPM)

EFG
10
EFCG-02-30

EFG
60
EFCG-03-125

EFG
EFCG-06-250

EFG
EFCG-10-500

20.6 (3000)

20.6 (3000)

20.6 (3000)

20.6 (3000)

10 : 0.3-10
(.08-2.6)

60 : 2-60
(.53-15.9)

3-250
(.79-66)

5-500
(1.32-132)

30 : 0.3-30
(.08-7.9)

125 : 2-125
(.53-33)

Min. Differential Pres.


MPa (PSI)

0.6 (90)

1.0 (145)

1.3 (190)

2.0 (290)

Free Flow
(EFCG Models Only.)
L /min (U.S.GPM)

40 (10.6)

130 (34.3)

280 (74.0)

550 (145)

Rated Current

600 mA

600 mA

600 mA

700 mA

Coil Resistance

43.5

43.5

43.5

43.5

Hysteresis

Less than 5%

Less than 7%

Less than 7%

Less than 7%

Repeatability

Less than 1%

Less than 1%

Less than 1%

Less than 1%

8.2 (18.1)

12.5 (27.6)

25 (55.1)

51 (113)

Approx. Mass
kg (lbs.)

Min. pressure difference required between inlet and outlet ports to maintain function as
pressure compensator.

Graphic Symbols

Model Number Designation

EFC

-02

-10

-31

Series Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

Design
Number

Design
Standards

02

10 : 10 (2.6)
30 : 30 (7.9)

31

03

60 : 60 (15.9)
125 : 125 (33)

26

06

250 : 250 (66)

22

10

500 : 500 (132)

11

EF :
Proportional ElectroHydraulic Flow Control
Valve
EFC :
Proportional ElectroHydraulic Flow Control
and Check Valve

G:
Sub-plate
Mounting

EFG-

Refer to

Note: If you are going to use the model with pressure compensator stroke adjustment screw, consult
your Yuken representative in advance.
Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

No.4

O
M

O
M

EFCG-

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03/06/10
CONTROLS
Sub-plate / Instructions / Others
Attachment
Mounting Bolts
Socket Head Cap Screw

Valve Model
Numbers

Japanese Std. "JIS" and European Design Std.

N. American Design Std.

EFG-02
EFG-03
EFG-06

EFG-10

Qty.

M8 75 Lg.

5/16-18 UNC 3 Lg.

M10 100 Lg.

3/8-16 UNC 4 Lg.

M16 130 Lg.

5/8-11 UNC 5 Lg.

M20 160 Lg.

3/4-10 UNC 6-1/2 Lg.

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
the Catalogue No. Pub. EC-1305).
Model Numbers: AME-D-S--32
AME-DF-S--22
AME-T-S--22

Sub-plate
Valve
Model
Numbers

Japanese Standard "JIS"

European Design Standard

N. American Design Standard

Thread Size

Sub-plate
Model Numbers

Thread Size

Sub-plate
Model Numbers

Thread Size

Approx. Mass
kg (lbs.)

EFGM-02X-20

Rc 3/8

EFGM-02X-2080

3/8 BSP.F

EFGM-02X-2090

3/8 NPT

2.3 (5.1)

EFGM-02Y-20

Rc 1/2

EFGM-02Y-2080

1/2 BSP.F

EFGM-02Y-2090

1/2 NPT

3.1 (6.8)

EFGM-03Y-20

Rc 3/4

EFGM-03Y-2080

3/4 BSP.F

EFGM-03Y-2090

3/4 NPT

5.7 (12.6)

EFGM-03Z-20

Rc 1

EFGM-03Z-2080

1 BSP.F

EFGM-03Z-2090

1 NPT

5.6 (12.3)

EFG -06
EFCG

EFGM-06X-20

Rc 1

EFGM-06X-2080

1 BSP.F

EFGM-06X-2090

1 NPT

12.5 (27.6)

EFGM-06Y-20

Rc 1-1/4

EFGM-06Y-2080

1-1/4 BSP.F

EFGM-06Y-2090

1-1/4 NPT

16 (35.3)

EFG -10
EFCG

EFGM-10Y-10

1-1/2, 2
Flange
Mounting

EFGM-10Y-1080

1-1/2, 2
Flange
Mounting

EFGM-10Y-1090

1-1/2, 2
Flange
Mounting

37 (81.6)

Sub-plate
Model Numbers

EFG -02
EFCG
EFG -03
EFCG

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should
have a good machined finish.
When ordering the EFGM-10Y, see Type F3 Pipe Flange Kits on Catalogue No. Pub. EC-3001 and order an appropriate pipe flange kit also.

Models with Pressure Compensator Stroke Adjustment Screw


A models with pressure compensator stroke adjustment screw is optionally available to minimize the actuator protrusion
(jumping) at startup. For the details, please consult us or your Yuken distributors.

Instructions
Drain Back Pressure
Check that the drain back pressure does not exceed 0.2 MPa (29 PSI).
Models with Check Valve
A models with check valve makes it possible to obtain a free flow in the direction opposite that of the controlled flow
without respect to the input current.

No.5

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03/06/10
CONTROLS
Installation Drawing
EFG/EFCG-02--31/3190
EFG/EFCG-03--26/2690

Cable Departure
Cable Applicable: Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area . . . Not Exceeding 1.5 mm2
(.002 sq. in.)
39
P
(1.54)

Inlet Port for Controlled Flow or


Outlet Port for Reversed Free Flow

Drain Port
Outlet Port for
Controlled Flow or
Inlet Port for
C
Reversed Free
Flow

45
40
(1.77) (1.57)

Air Vent
3 (.12) Hex. Soc.

97
(3.82)
85
(3.35)

Connector
The direction can
be altered to every
90 degree angles.

Locating Pin
6 (.24) Dia.
"U" Places
Mounting Surface
(O-Rings Furnished)

"Q" Dia. Through


"S" Dia. Spotface
4 Places

B
A

6
(.24)

T
N
L

Manual Adjustment
M4 Thd. (Internal Thd.)

INC.

Manual adjustment can be done by screwing for example an M420 L screw in the M4 thread or pushing
in a rod etc. there.
Dimensions

Model
Numbers

mm (Inches)
J

EFG-02

96
76.2
(3.78) (3.00)

9.9
(.39)

38.1
106
82.6 11.7
(1.50) (4.17) (3.25) (.46)

108
46.3
195
81
8.8
66
(1.82) (7.68) (3.19) (2.60) (4.25) (.35)

14
(.55)

65
(2.56)

EFG-03

125 101.6
(4.92) (4.00)

11.7
(.46)

50.8
130 101.6 14.2
(2.00) (5.12) (4.00) (.56)

125
61.8
212
98
11
85
(2.43) (8.35) (3.86) (3.35) (4.92) (.43)

17.5
(.69)

84
(3.31)

EFG/EFCG-06-250-22/2290
EFG/EFCG-10-500-11/1190

DIMENSIONS IN
MILLIMETRES (INCHES)
Cable Departure
Cable Applicable: Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area . . . Not Exceeding 1.5 mm2
(.002 sq. in.)
39
Q
(1.54)

Inlet Port for Controlled Flow or


Outlet Port for Reversed Free Flow

Air Vent
3 (.12) Hex. Soc.

97
(3.82)
85
(3.35)
40
(1.57)

Connector
The direction can
be altered to every
90 degree angles.

Two Locating Pins


"V" Dia.

45
(1.77)

Drain Port

Outlet Port for


Controlled Flow or
Inlet Port for
Reversed Free
C
Flow

Mounting Surface
(O-Rings Furnished)

B
A

"S" Dia. Through


"T" Dia. Spotface
4 Places

N
L

Manual Adjustment
M4 Thd. (Internal Thd.)

INC.

Manual adjustment can be done by screwing for example an M420 L screw in the M4 thread or pushing
in a rod etc. there.
Model
Numbers

Dimensions
A

mm (Inches)
K

EFG-06

17
180 146.1
(7.09) (5.75) (.67)

73.1
174 133.4 20.3
(2.88) (6.85) (5.25) (.80)

105
99
244
130
(3.90) (9.61) (5.12) (4.13)

7
(.28)

157
17.5
(6.18) (.69)

26
103.5
(1.02) (4.07)

16
(.63)

EFG-10

244 196.9 23.5


(9.61) (7.75) (.93)

25
98.5
228 177.8
(3.88) (8.98) (7.00) (.98)

137
160
144.5 274
(5.69) (10.79) (6.30) (5.93)

10
(.39)

21.5
187
(7.36) (.85)

32
135
(1.26) (5.31)

18
(.71)

No.6

E Series
Sub-plate for
PROPORTIONAL
40 Series Flow Control (and Check) Valves
CONTROLS
Installation Drawing
Sub-plate
EFGM-02X/02Y-20/2080/2090

Sub-plate
Model Numbers

96(3.78)
79.4(3.13)
76.2(3.00)
54
(2.13)
38.1
(1.50)
9.5
(.37)

2.5(.10)
21.9(.86)
E

10
(.39)

120(4.72)

EFGM-02X-20
EFGM-02Y-20

Rc 1/2

EFGM-02X-2080

3/8 BSP.F

EFGM-02Y-2080

1/2 BSP.F

EFGM-02X-2090

3/8 NPT

EFGM-02Y-2090

1/2 NPT

Thread Size
"B" Thd.

"C" Thd.

Rc 1/4
M8
1/4 BSP.F
1/4 NPT

5/16-18 UNC

7(.28) Dia.
10(.39) Deep

EFGM-02Y-20

11.5
(.45)

"K" Dia.
"B" Thd.
(From Rear)

EFGM-02X-2080

8.6
(.34)

Dimensions mm (Inches)
E
F
H
J
75.9
25
(2.99) (.98)
14
(.55)
72.9
35
(2.87) (1.38) 14
(.55) 15.2
75.9
25
(2.99) (.98)
(.60)

EFGM-02Y-2080

11.5
(.45)

35
72.9
(2.87) (1.38)

EFGM-02X-2090

8.6
(.34)

75.9
25
(2.99) (.98)

EFGM-02Y-2090

11.5
(.45)

72.9
35
(2.87) (1.38)

82.6(3.25)

78(3.07)

106(4.17)

"A" Thd.
2 Places
(From Rear)

52.4(2.06)

44.3(1.74)

23.8(.94)

8.8(.35) Dia. Through


14(.55) Dia. Spotface
4 Places

14
(.55)

"C" Thd.
"H" Deep
4 Places

"J" Dia.
2 Places

11.1(.44)

9.9
(.39)

"A" Thd.
Rc 3/8

EFGM-02X-20

15
(.59)
16
(.63)

140(5.51)

Sub-plate
Model Numbers

D
8.6
(.34)

15
(.59)
18
(.17)

14
(.55)

K
11
(.43)

11.7
(.46)

11
(.43)

DIMENSIONS IN
MILLIMETRES (INCHES)

EFGM-03Y/03Z-20/2080/2090

47.8
(1.88)
92.2(3.63)

86.5(3.41)

EFGM-03Y-20

"A" Thd.
Rc 3/4

EFGM-03Z-20

Rc 1

EFGM-03Y-2080 3/4 BSP.F


EFGM-03Z-2080

1 BSP.F

EFGM-03Y-2090

3/4 NPT

EFGM-03Z-2090

1 NPT

Thread Size
"B" Thd.
"C" Thd.

D
mm(in.)

Rc 1/4
M10

18
(.71)

3/8-16 UNC

21
(.83)

1/4 BSP.F
1/4 NPT

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places
11(.43) Dia.

146(5.75)
168(6.61)

40
(1.57)

11
(.43)

101.6(4.00)

11.1(.44)
22.2(.87)

Sub-plate
Model Numbers

19
(.75)
20
(.79)

"A" Thd.
2 Places
(From Rear)

7(.28) Dia. 8(.31) Deep


2 Places

61.8(2.43)

16.1
(.63)
54
(2.13)

81.5(3.21)

130(5.12)

14.2
(.56)

"B" Thd.
(From Rear)

"C" Thd. "D" Deep


4 Places

28.6
(1.13)

125(4.92)
102.4(4.03)
101.6(4.00)
75
(2.95)
50.8
(2.00)
20.6
(.81)

11.7(.46)
0.8(.03)

23(.91) Dia.
2 Places

No.7

E Series
Sub-plate for
PROPORTIONAL
40 Series Flow Control (and Check) Valves
CONTROLS
Installation Drawing
180(7.09)
146.1(5.75)
144.4(5.69)
104.8(4.13)

17
(.67)

"C" Thd.
"P" Deep
4 Places

29(1.14) Dia.
2 Places
17.5(.69) Dia. Through
26(1.02) Dia. Spotface
4 Places

73(2.87)

12.7(.50)

24
(.94)

22.2(.87)

"B" Thd. (From Rear)

14(.55) Dia.

19
(.75)

"A" Thd.

EFGM-06X-20

Rc 1

EFGM-06Y-20

Rc 1-1/4

EFGM-06X-2080

1 BSP.F

Thread Size
"B" Thd.

"C" Thd.

Rc 3/8
M16
3/8 BSP.F
EFGM-06Y-2080 1-1/4 BSP.F
EFGM-06X-2090

1 NPT
3/8 NPT

5/8-11 UNC

EFGM-06Y-2090 1-1/4 NPT

D
101.1
(3.98)
95.3
(3.75)
101.1
(3.98)
95.3
(3.75)
101.1
(3.98)
95.3
(3.75)

E
14.3
(.56)
19.3
(.76)
14.3
(.56)
19.3
(.76)
14.3
(.56)
19.3
(.76)

F
55.2
(2.17)
67
(2.64)
55.2
(2.17)
67
(2.64)
55.2
(2.17)
67
(2.64)

48(1.89) Dia.
2 Places
(From Rear)

98.5(3.88)
"B" Thd.
"C" Deep
4 Places

36
(1.42)

244(9.61)
198.4(7.81)
196.9(7.75)
144.5(5.69)
34.9
(1.37)

73
(2.87)

43.5(1.71) Dia.
2 Places
"D" Thd. "E" Deep
8 Places (From Rear)

Sub-plate
Model Numbers

14(.55) Dia.

"A" Thd.
(From Rear)

183.5(7.22)
284(11.18)
334(13.15)

No.8

50(1.97)

48(1.89)

"F3" Series Pipe Flange Kits


Refer to the Catalogue
No. Pub. EC-3001.

Rc 3/8
3/8 BSP.F

EFGM-10Y-1090

3/8 NPT

EFGM-10Y-10
21.5(.85) Dia. Through
32(1.26) Dia. Spotface
4 Places

"A" Thd.

EFGM-10Y-1080

Sub-plate
Model Numbers

80
(3.15)

25
(.98)

73
43.5 (2.87)
(1.71)
148.5(5.85)

250(9.84)

73
(2.87)

228(8.98)

29(1.14)

73
(2.87)

17.3(.68)

55.5(21.9)

144.5(5.69)

177.8(7.00)

EFGM-10Y-10

20(.79) Dia.
15(.59) Deep
2 Places

mm (Inches)
K
N
P
Q
S
34
35
(1.38) (1.34)
106
14
(4.17) (.55)
39
40
(1.57) (1.54) 30
34 (1.18)
15.2
35
(1.38) (1.34)
116 (.60)
(4.57) 15
39
40
(.59)
(1.57) (1.54)
34
35
(1.38) (1.34) 35
106
14
39 (1.38) (4.17) (.55)
40
(1.57) (1.54)

DIMENSIONS IN
MILLIMETRES (INCHES)

25
(.98)

1.6(.06)

Dimensions
H
J
45
137.8
(5.43) (1.77)
60
132
(5.20) (2.36)
45
137.8
(5.43) (1.77)
60
132
(5.20) (2.36)
45
137.8
(5.43) (1.77)
60
132
(5.20) (2.36)

EFGM-10Y-10/1080/1090
23.5(.93)

212(8.35)
250(9.84)

Sub-plate
Model Numbers

133.4(5.25)

99(3.90)

17(.67) Dia.
10(.39) Deep
2 Places

33(1.30)

"A" Thd.
2 Places
(From Rear)

104.8(4.13)

3.7
(.15)
D

126(4.96)

174(6.85)

1.6(.06)

41.3(1.63)

EFGM-06X/06Y-20/2080/2090

EFGM-10Y-1080
EFGM-10Y-1090

Thread Size
"B" Thd.

"C" Thd.

M20

M16

3/4-10 UNC

5/8-11 UNC

mm (Inches)
D
E
30 (1.18)

30 (1.18)

34 (1.34)

35 (1.38)

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03/06/10
CONTROLS
Typical Performance Characteristics
Input Current vs. Flow
EFG -02
EFCG

U.S.GPM L /min
8
30
25

EFG-02-30

Flow Rate

6
5
4
3

Flow Rate

U.S.GPM
32.5
30.0

20
15
10

2
1
0

5
EFG-02-10
0
0 100 200 300 400 500 600

25.0
20.0

100
80

15.0

60

10.0

40

5.0

20

Input Current mA

EFG -03
EFCG

L /min
125
120

EFG-03-125

EFG-03-60

0
0

100 200 300 400 500 600

Input Current mA

EFG
EFCG -06

EFG
EFCG -10

50
40
30

U.S.GPM L /min
140
500
120
400
100

200

Flow Rate

Flow Rate

U.S.GPM L /min
250
65
60

150

60

20
50
0
0

300
200

40

100

20
10

80

100
0
0

100 200 300 400 500 600 700

Input Current mA

100 200 300 400 500 600

Input Current mA

EFG
EFCG -02

Flow Rate

U.S.GPM L /min
8.5
32
8.0
30
7.5
28
4.1
4.0
3.9
3.8

15.5
15.0
14.5

.550
.525
.500

2.1
2.0
1.9
0.4

1.0
100

2.0

5.0

200 500

10

U.S.GPM
34
33
32

L /min
130
125
120

Flow Rate

Differential Pressure vs. Metred Flow

14.0
13.5
13.0

52.5
50.0
47.5

.96
.90

3.7
3.5
3.3

EFG
EFCG -03

0.8 1.0

20 MPa

150 200

1000 2000 3000


PSI

Flow Rate

28
26
24

110
100
90

2.8
2.6
2.4

11
10
9
1

EFG
EFCG -06

2
200 300 500

10
1000

20 MPa

2000 3000
PSI

Differential Pressure

U.S.GPM
132
130
128
126

L /min
500
490
480

Flow Rate

L /min
260
250
240

5.0

10

20 MPa

500 1000 2000 3000


PSI

Differential Pressure

Differential Pressure

U.S.GPM
68
66
64

2.0

82
80
78
76

310
300
290

1.45
1.40
1.35
1.30

5.4
5.2
5.0
1

EFG
EFCG -10

2
300

5
500

20 MPa

10
1000

2000 3000
PSI

Differential Pressure

No.9

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03/06/10
CONTROLS
Typical Performance Characteristics
Step Response

Viscosity vs. Flow

These characteristics have been obtained by measuring on each valve.


Therefore , they may vary according to a hydraulic circuit to be used.

L /min
35

U.S.GPM L /min
140
35
120
30
100
25
80
20
60
15
40
10

30 L /min
(7.9 U.S.GPM)

30
25
20

15 L /min
(4 U.S.GPM)

15
10

0.2s

5
0

125 L /min
(33 U.S.GPM)

Flow Rate

Flow Rate

U.S.GPM
9
8
7
6
5
4
3
2
1
0

EFG -03
EFCG

5
0

Step Signal

Flow Rate

EFG -02
EFCG

U.S.GPM
8.5
8.0
7.5
7.0
5.0
4.5
4.0
3.5

60 L /min
(15.9 U.S.GPM)

1.5
1.0
.5
0

Step Signal

Time

EFG
EFCG -02

Oil: ISO VG 46 Oil

30
27
19
16
13
6
3

0
10 20 30 40 50 60 70 C
Temperature
50 60 80 100 120 140 160 F
200 10075 50 40 30 20 15 mm2/s
Viscosity
1000 500 300 200
100 80 SSU

0.2s

20

L /min
33

Time

EFG -03
EFCG

150

10
0

50

100

0.2s
Step Signal

50

200

25

100

Flow Rate

125 L /min
(33 U.S.GPM)

500 L /min
(132 U.S.GPM)

250 L /min
(66 U.S.GPM)
0.2s
Step Signal

Time

Time

U.S.GPM L /min
280
70
250
65
60
220

Frequency (Hz)

Frequency (Hz)

0.7 1

4 7 10 20 40
Gain

Phase

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

Input Current : 440 100 mA


Pressure : 6.9 MPa (1000 PSI)

0
-10
-20

Gain
Phase

7 10

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

0
-5
-10
-15
-20

0.1 0.2

0.7 1

Gain

Input Current : 475 125 mA


Pressure : 6.9 MPa (1000 PSI)

EFG
EFCG -06

Oil: ISO VG 46 Oil

155
125
95
60
30

0
10 20 30 40 50 60 70 C
Temperature
50 60 80 100 120 140 160 F
200 10075 50 40 30 20 15 mm2/s
Viscosity
1000 500 300 200
100 80 SSU

4 710 20

Phase

40
35
30
25
15
10
5
0

Gain
Phase

Gain (dB)

Input Current : 460 70 mA


Pressure : 6.9 MPa (1000 PSI)

No.10

30

Frequency (Hz)

Phase (deg.)

0
-5
-10
-15
-20
Gain (dB)

Phase (deg.)

0
-20
-40
-60
-80
-100
-120

4 7 10

EFG
EFCG -10

Frequency (Hz)
0.7 1

0.7 1 2

Input Current : 460 70 mA


Pressure : 6.9 MPa (1000 PSI)

EFG
EFCG -06
0.1 0.2

0.1 0.2

Gain (dB)

0
-10
-20

EFG
EFCG -03

Phase (deg.)

0
-20
-40
-60
-80
-100
-120
-140
-160
-180

0.2

EFG
EFCG -02

Gain (dB)

Phase (deg.)

Frequency Response

U.S.GPM L /min
560
140
500
130
120
440

Flow Rate

40
30
20

U.S.GPM L /min
600
150
500
125
400
100
300
75

250 L /min
(66 U.S.GPM)

Flow Rate

Flow Rate

U.S.GPM L /min
300
70
250
60
200
50

EFG -10
EFCG

Flow Rate

EFG
EFCG -06

U.S.GPM L /min
Oil: ISO VG 46 Oil
140
35.0
125
32.5
30.0
110
75
20.0
17.5
60
15.0
12.5
45
30
7.5
5.5
15
2.5
0
0
10 20 30 40 50 60 70 C
Temperature
50 60 80 100 120 140 160 F
200 10075 50 40 30 20 15 mm2/s
Viscosity
1000 500 300 200
100 80 SSU

80
70
60
50
30
20
10
0

EFG -10
EFCG

Oil: ISO VG 46 Oil

310
250
190
120
60

0
10 20 30 40 50 60 70 C
Temperature
50 60 80 100 120 140 160 F
200 10075 50 40 30 20 15 mm2/s
Viscosity
1000 500 300 200
100 80 SSU

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03/06/10
CONTROLS
Typical Performance Characteristics
Pressure Drop for Reversed Free Flow (Only for "EFCG" Models)
Oil Viscosity: 35 mm2/s (164 SSU)
Specific Gravity: 0.850

PSI

MPa
0.5

PSI
70
60
50
40
30
20
10
0

EFCG-03

Throttle Closed

0.4
0.3

Pressure Drop

Pressure Drop

EFCG-02

Throttle Fully Open

0.2
0.1
0

80

Throttle Closed

60

10

20

2.5

5.0

30
7.5

40
10.0

0.4
Throttle Fully Open

40
20
0

MPa
0.6

0.2
0
0

50 L /min

50

12.5 U.S.GPM

10

100
20

30

1.0
P

Throttle Closed

0.8
0.6
Throttle Fully Open

0.4
0.2
0

100
25

200
50

40

50 U.S.GPM

EFCG-10

Pressure Drop

Pressure Drop

EFCG-06
MPa

200 L /min

Free Flow

Free Flow

PSI
160
140
120
100
80
60
40
20
0

150

300
75

400 L /min
100 U.S.GPM

PSI
160
140
120
100

MPa

80
60
40
20
0

0.6

1.0
Throttle Closed

0.8

Throttle Fully Open

0.4
0.2
0
0

200

50

Free Flow

400

100

600

150

800 L /min

200 U.S.GPM

Free Flow

For any other viscosity, multiply the factors in the table below.
mm2/s 20 40 60 80 100
SSU 98 186 278 371 464
Factor
0.87 1.03 1.14 1.23 1.30

Viscosity

For any other specific gravity (G'), the pressure drop ( P') may be obtained from the formula below.
P'= P (G'/0.850)

No.11

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-02/03
CONTROLS
Spare Parts List
EFG/EFCG-02--31/3190
EFG/EFCG-03--26/2690
EFG-03
13 31 8

7 40 2 21

44

24 39 5

EFG-02

6 12 29 36

5 39 33 4 29 36

15 32 35

25 10 34 11

Detail of A
38 16 37 3

1 27 34

43 42 23

41

1 30

26 1

6 22 15 12 30 35

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

With Check Valve (EFCG-02, 03)


1

18 9 28 14 17

List of Seals and Solenoids Ass'y


Item

Name of Parts

23
27
28
29
30
31
32
33
41
42
43
44

Solenoid Ass'y
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Fastener Seal

Part Numbers
EFG-02
EFG-03
E321-45-20
E321-45-20
SO-NB-P18
SO-NB-P18
SO-NB-P21
SO-NB-P10A
SO-NB-P28
SO-NB-P18
SO-NB-P31
SO-NB-P22
SO-NB-G35
SO-NB-G25
SO-NB-P18
SO-NB-P22
SO-NB-G45
SO-NB-G45
SO-NB-G35
SO-NB-G35
SO-NA-P4
SO-NA-P4
SG-FCF-4
SG-FCF-4

List of Seal Kits


Qty.
1
1
1
2
1
1
1
1
1
1
1
1

Note: O-rings (Item 41, 42, 43) and the fastener seal (Item 44) are
included in the solenoid assembly.
Note: The connector assembly GDM-211-B-11 (Item 24) is not
included in the solenoid assembly.
Note: When ordering seals, please specify the seal kit number from the
table right.

No.12

Model Numbers
EFG-02--31
EFCG-02--31
EFG-03--26
EFCG-03--26

Seal Kit Numbers


KS-EFG-02-31
KS-EFCG-02-31
KS-EFG-03-26
KS-EFCG-03-26

E Series
40 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-06/10
CONTROLS
Spare Parts List
EFG/EFCG-06-250-22/2290
EFG/EFCG-10-500-11/1190
12 5 26 15 11 26 14 30 13

44

24 35 22 2

9 29 20
21 19 32 25

Detail of A

6 34 1 10

43 42 23

41

28

1 27

With Check Valve (EFCG-06, 10)

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

16 18 31 14

Section B-B

Item

Name of Parts

23
26
27
28
29
30
31
32
41
42
43
44

Solenoid Ass'y
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Fastener Seal

Part Numbers
EFG-06
EFG-10
E321-45-20
E321-45-20
SO-NB-G75
SO-NB-P50
SO-NB-G60
SO-NB-P44
SO-NB-P50
SO-NB-P34
SO-NB-P48
SO-NB-P32
SO-NB-P34
SO-NB-P21
SO-NB-P26
SO-NB-P21
SO-NA-P10
SO-NA-P10
SO-NB-G45
SO-NB-G45
SO-NB-G35
SO-NB-G35
SO-NA-P4
SO-NA-P4
SG-FCF-4
SG-FCF-4

List of Seal Kits

List of Seals and Solenoid Ass'y


Qty.
1
3
1
1
2
1
1
1
1
1
1
1

Model Numbers
EFG-06-250-22
EFCG-06-250-22
EFG-10-500-11
EFCG-10-500-11

Seal Kit Numbers


KS-EFG-06-22
KS-EFCG-06-22
KS-EFG-10-11
KS-EFCG-10-11

Note: O-rings (Item 41, 42, 43) and the fastener seal (Item 44) are
included in the solenoid assembly.
Note: The connector assembly GDM-211-B-11 (Item 24) is not
included in the solenoid assembly.
Note: When ordering seals, please specify the seal kit number from the
table right.

No.13

E Series
10 Series Flow Control (and Check) Valves
PROPORTIONAL
EFG/EFCG-03/06 (3/8, 3/4)
CONTROLS
Sub-plate Mounting
Specifications / Model Number Designation

Specifications
Model No.
Description
Max. Operating Pressure
MPa (PSI)
Metred Flow Adj. Range
L /min (U.S.GPM)

EFG -03- 60
EFCG
125

EFG -06-250
EFCG

20.6 (3000)

24.5 (3550)

60 : 1-60
(.26-15.9)
125 : 1-125
(.26-33)

2.5-250
(.66-66)

Min. Differential Pressure 1


MPa (PSI)

1.0 (145)

1.0 (145)

Free Flow (EFCG Models Only)


L /min (U.S.GPM)

130 (34.3)

280 (74.0)

1.0 (145)

1.5 (220)

Min Pilot Pressure

MPa (PSI)
at Normal
Pilot Flow
L /min (U.S.GPM) at Transition

0.5 (.13)

1 (.26)

2.6 (.69)

4 (1.06)

Rated Current

780 mA

820 mA

10

10

Less than 3%

Less than 3%

Less than 1%

Less than 1%

10 (22.1)

25 (55.1)

Coil Resistance
Hysteresis
Repeatability
Approx. Mass

kg (lbs.)

Graphic Symbols
Internal Pilot

1. Min pressure difference required between inlet and outlet ports to maintain function as
pressure compensator.
2. The minimum required value for the external pilot type.

O
M

EFG-

Model Number Designation

EFC

-03

-125

Series Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

03

60 : 60 (15.9)
125 : 125 (33)

EF :
Proportional
Electro-Hydraulic
Flow Control Valve
EFC :
Proportional
Electro-Hydraulic
Flow Control and
Check Valve

G:
Sub-plate
Mounting

-E

-51

Design
Pilot
Connection Number

None:
Internal
Pilot

Design
Standards

Refer to
06

250 : 250 (66)

E:
External
Pilot

51

O
M

EFCG-

External Pilot

51

Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

No.14

O
M

EFG-

O
M

EFCG-

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Sub-plate / Instructions / Others
Attachment
Mounting bolts
Socket Head Cap Screw

Valve Model
Numbers

Qty.

Japanese Std. "JIS" and European Design Std.

N. American Design Std.

M10 80 Lg.

3/8-16 UNC 3-1/4 Lg.

M16 130 Lg.

5/8-11 UNC 5 Lg.

EFG-03

EFG-06

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
the Catalogue No. Pub. EC-1305).
Model Numbers: AME-D-10--20
AME-D2-1010--10
SK1022---11
SK1015-11 (For DC power supply)
AMN-D-10 (For DC power supply)

Sub-plate
Valve
Model
Numbers

Japanese Standard "JIS"

European Design Standard

N. American Design Standard

Thread Size

Sub-plate
Model Numbers

Thread Size

Sub-plate
Model Numbers

Thread Size

Approx. Mass
kg (lbs.)

EFGM-03Y-30

Rc 3/4

EFGM-03Y-3080

3/4 BSP.F

EFGM-03Y-3090

3/4 NPT

5.7 (12.6)

EFGM-03Z-30

Rc 1

EFGM-03Z-3080

1 BSP.F

EFGM-03Z-3090

1 NPT

5.6 (12.3)

EFGM-06X-30

Rc 1

EFGM-06X-3080

1 BSP.F

EFGM-06X-3090

1 NPT

12.5 (27.6)

EFGM-06Y-30

Rc 1-1/4

EFGM-06Y-3080

1-1/4 BSP.F

EFGM-06Y-3090

1-1/4 NPT

16 (35.3)

Sub-plate
Model Numbers

EFG -03
EFCG
EFG -06
EFCG

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used,
the mounting surface should have a good machined finish.

[Example of Circuit]

Instructions
Drain Back Pressure
Check that the drain back pressure dose not exceed
0.2 MPa (29 PSI).
Pilot Type Selection
This valve is constructed so as to operate at a predetermined pilot pressure. For the 03, a pilot pressure of
1 MPa (145 PSI) or higher is required. For the 06, the
requied pilot pressure is 1.5 MPa (220 PSI) or higher.
To obtain such a required pilot pressure, select the pilot
type according to the circuit examples on the right.
/ 2
Use the external pilot type (pilot connection code: E)
whether a metre-in or metre-out circuit is employed.

1
P.P.

P.P.
O
M

EFCG-03--E-51
06

EFCG-03--E-51
06
A

4
P.P.

O
M

O
M

EFG-03--51
06

O
M

EFG-03--E-51
06

Use the internal pilot type (pilot connection code: None)


4

Use the external pilot type (pilot connection code: E)

No.15

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Installation Drawing
EFG -03- 60 - -51/5190
EFCG
125

Drain Port

11.7
(.46)

Cable Departure
Cable Applicable: Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area . . . Not Exceeding 1.5 mm2
(.002 sq. in.)
39
(1.54)

50.8
(2.00)
101.6
(4.00)
125
(4.92)

158.1
(6.22)

69.5
(2.74)
57.5
(2.26)

61.8
(2.43)
101.6
(4.00)
125
(4.92)

Connector
The direction can
be altered to every
90 degree angles.

Outlet Port for


Controlled Flow or
Inlet Port for
Reversed Free
Flow

11 (.43) Dia. Through


17.5 (.69) Dia. Spotface
4 Places
11.7
(.46)

Air Vent
3 (.12) Hex. Soc.
3 Places

Manual
Adjustment
Screw
3 (.12) Hex. Soc.

Two Locating Pins


6 (.24) Dia.
Mounting Surface
(O-Rings Furnished)
INC.

68
(2.68)
69
(2.72)
88
(3.46)

Inlet Port for Controlled


Flow or Outlet Port for
Reversed Free Flow
Pilot Port

6
(.24)

235.5
(9.27)

DIMENSIONS IN
MILLIMETRES (INCHES)

EFG -06-250- -51/5190

EFCG

Outlet Port for


Controlled Flow or
Inlet Port for
Reversed Free
Flow
17
(.67)

No.16

39
(1.54)

Manual
Adjustment
Screw
3 (.12) Hex. Soc.

73
(2.87)
146
(5.75)
180
(7.09)

199.1
(7.84)

69.5
(2.74)
57.5
(2.26)

Drain Port

Cable Departure
Cable Applicable: Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area . . . Not Exceeding 1.5 mm2
(.002 sq. in.)

20.3
(.80)

Air Vent
3 (.12) Hex. Soc.
3 Places

104.8
(4.13)
133.4
(5.25)
174
(6.85)

Connector
The direction can
be altered to every
90 degree angles.

Inlet Port for Controlled


Flow or Outlet Port for
Reversed Free Flow

Two Locating Pins


16 (.63) Dia.

Mounting Surface
(O-Rings Furnished)
104
(4.09)
105
(4.13)
120
(4.72)

INC.

17.5 (.69) Dia. Through


26 (1.02) Dia. Spotface
4 Places
Pilot Port

276.5
(10.89)

7
(.28)

E Series
Sub-plate for
PROPORTIONAL
10 Series Flow Control (and Check) Valves
CONTROLS
Installation Drawing
Sub-plate
EFGM-03Y, 03Z-30/3080/3090
125(4.92)

11.7(.46)

102.4(4.03)
75
(2.95)
50.8
(2.00)
20.6
(.81)

"D" Thd. "E" Deep


4 Places

86.5(3.41)

11.1
(.44)
28.6
(1.13)
61.8
(2.43)

92(3.62)

7(.28) Dia. 8(.31) Deep


2 Places

81.5
(3.21)
54
(2.13)
16.1
(.63)

14.2
(.56)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

130(5.12)

23(.91) Dia.
2 Places

101.6(4.00)

101.6(4.00)

0.8
(.03)

"C" Thd.
(From Rear)

Sub-plate
Model Numbers
22.2(.87)

"B" Thd.
2 Places

6(.24) Dia. "C" Thd.


(From Rear)

47.8
(1.88)

11(.43) Dia.

92.2(3.63)

EFGM-03Y-30

Rc 3/4

EFGM-03Z-30

Rc 1

19(.75)

146(5.75)

40
(1.57)

168(6.61)

EFGM-03Z-3080

1 BSP.F

EFGM-03Y-3090

3/4 NPT

EFGM-03Z-3090

1 NPT

E
mm(in.)

Rc 1/4

EFGM-03Y-3080 3/4 BSP.F


20(.79)

11
(.43)

Thread Size
"C" Thd.
"D" Thd.

"B" Thd.

M10

18
(.71)

3/8-16 UNC

21
(.83)

1/4 BSP.F
1/4 NPT

DIMENSIONS IN
MILLIMETRES (INCHES)

EFGM-06X, 06Y-30/3080/3090
180(7.09)
17
(.67)

"A" Thd.
2 Places

104.8(4.13)
"C" Thd. "D" Deep
4 Places

136(5.35)

"B" Thd.
(From Rear)

33(1.30)
E

Sub-plate
Model Numbers

"B" Thd.
(From Rear)

"Q" Dia.

133.4(5.25)

126(4.96)

174(6.85)

85.7(3.37)

1.6
(.06)

104.8(4.13)

3.7(.15)

24
(.94)

22.2(.87)

41.3(1.63)

73(2.87)

12.7(.50)

17.5(.69) Dia. Through


26(1.02) Dia. Spotface
4 Places

29(1.14) Dia.
2 Places

146(5.75)
144.5(5.69)
108(4.25)

17(.67) Dia.
10(.39) Deep
2 Places

F
147(5.79)

19
(.75)

6(.24) Dia.

212(8.35)

EFGM-06X-30

"A" Thd.
Rc 1

EFGM-06Y-30

Rc 1-1/4

EFGM-06X-3080

1 BSP.F

EFGM-06Y-3080 1-1/4 BSP.F

250(9.84)

EFGM-06X-30

E
55.2 (2.17)

F
137.8 (5.43)

40 (1.57)

60 (2.36)

116
(4.57)

34 (1.34)

35 (1.38)

45 (1.77) 15.2 (.60)

39 (1.54)

40 (1.57)

60 (2.36)

15 (.59)

106
(4.17)

34 (1.34)

35 (1.38)

45 (1.77)

39 (1.54)

40 (1.57)

60 (2.36)

11
(.43)

132 (5.20)

14.3 (.56)

101.1 (3.98)

EFGM-06Y-3080

52 (2.05)

132 (5.20)

19.3 (.76)

91.3 (3.59)

EFGM-06X-3090

55.2 (2.17)

137.8 (5.43)

14.3 (.56)

101.1 (3.98)

52 (2.05)

132 (5.20)

19.3 (.76)

91.3 (3.59)

EFGM-06Y-3090

35
(1.38)

3/8 NPT 5/8-11 UNC

P
45 (1.77)

137.8 (5.43)

30
(1.18)

M16
3/8 BSP.F

N
35 (1.38)

52 (2.05)

EFGM-06X-3080

Rc 3/8

Dimensions mm (Inches)
H
J
K
L
14.3 (.56) 101.1 (3.98)
34 (1.34)
106
(4.17) 39 (1.54)
19.3 (.76) 91.3 (3.59)

55.2 (2.17)

EFGM-06Y-30

1 NPT

EFGM-06Y-3090 1-1/4 NPT

EFGM-06X-3090

Sub-plate
Model Numbers

Thread Size
"B" Thd. "C" Thd.

Q
11
(.43)

No.17

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Typical Performance Characteristics
Input Current vs. Flow
EFG -03
EFCG

EFG -06
EFCG
U.S.GPM L /min
250
65
60

U.S.GPM L /min
125
35
30

20

200

100

50
EFG-03-125

75

Flow Rate

Flow Rate

25

15

40
30

50

150

100

20

10
25

50

EFG-03-60

10

200

400

600

800

0
0

1000

200

Input Current mA

400

600

800

Input Current mA

Step Response
EFG -03
EFCG
L /min
150

U.S.GPM
35

Flow Rate

U.S.GPM
125 L /min
(33 U.S.GPM)

125

30

EFG -06
EFCG
70

25
20
15
10

75

60 L /min
(15.9 U.S.GPM)

50

0.2s

25

Step Signal

L /min
300

250 L /min
(66 U.S.GPM)

250

60

100

Flow Rate

These characteristics have been


obtained by measuring on each
valve. Therefore , they may vary
according to a hydraulic circuit
to be used.

50

200

40

150

125 L /min
(33 U.S.GPM)

100

0.2s

30
20
10

50

Step Signal

Time

Time

Frequency Response
0.1

0
-20

-10

-40

-20

-60

-30

-80
-100
-120

0.2

0.4

0.7 1

Frequency (Hz)
2
4

7 10

20

40

70

40

70

Gain

Gain (dB)

Phase (deg.)

EFG -03
EFCG

Phase

-140
Flow Rate : 6515 L /min (174.0 U.S.GPM)
Supply Pressure : 13.7 MPa (2000 PSI)

-160
-180

0
-20

Phase (deg.)

0.1

-20

-60

-30

-80
-100
-120

0.2

0.4

0.7 1

Frequency (Hz)
2
4

7 10

-10

-40

Gain (dB)

EFG
EFCG -06

Gain

Phase

-140
-160
-180

No.18

Flow Rate : 12525 L /min (336.6 U.S.GPM)


Supply Pressure : 13.7 MPa (2000 PSI)

20

1000

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Typical Performance Characteristics
Viscosity vs. Flow

EFG -03
EFCG

U.S.GPM L /min
37.5
140
35.0
125
32.5

75

12.5

45

7.5
5.0
2.5

30

Flow Rate

110

20.0
17.5
15.0

U.S.GPM L /min
75
280
70
250
65
60
220

Oil: ISO VG 46 Oil

60

15
0
10

20

30

40

50

60

70 C

Temperature

40
35
30
25

155

15
10
5
0

60

Oil: ISO VG 46 Oil

125
95

30
0
10

20

30

40

50

60

70 C

140
20

160 F
2
15 mm /s

Temperature

50 60
200

80
100 75

100
120
50 40 30

140
20

160 F
15 mm2/s

Viscosity

50 60
200

80
100 75

100
120
50 40 30

Viscosity
1000 500

300 200

100

Differential Pressure vs. Metred Flow

1000

SSU

U.S.GPM
37.5
35.0
32.5
30.0

Flow Rate

EFG -03
EFCG

80

500

300 200

100

80

SSU

L /min
140
125
110

22.5
20.0
17.5
15.0

85

10.0
7.5
5.0
2.5

40

70
55

25
10
0
0

500

1000

12
1500

16
2000

20
2500

MPa

3000 PSI

Differential Pressure

EFG -06
EFCG

U.S.GPM L /min
70 270

Flow Rate

Flow Rate

30.0

EFG -06
EFCG

65

250

60

230

35

140

30
25

120

10

40

20

100

0
0

500

1000

12
1500

16
2000

20
2500

MPa

3000 PSI

Differential Pressure

No.19

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Spare Parts List
CAUTION

EFG -03- - -51/5190

EFCG
18 32 16

When making replacement of seals, please do it carefully after reading


through the relevant instructions in the Operator's Manual.

29 37 17 19

26 4

42 5 13 10

40 34 27

List of Seal Kits

15 14 41 30 31

25 7 28 12 11 31 39 35

31 38 33

21 22 36 24 23

Model Numbers
EFG-03---51
EFCG-03---51

Seal Kit Numbers


KS-EFG-03-51
KS-EFCG-03-51

List of Seals and Solenoid Ass'y

With Check Valve (EFCG-03)


Note: The connector assembly GDM-211-B-11 (Item 26) is not included in the solenoid
assembly.
Note: When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for solenoid ass'y is included in the seal kit.
For the detail of the solenoid ass'y seals, see the Catalogue No. Pub. EC-1302.

Item
25
32
33
34
35
36
37
38
39
40

Name of Parts
Solenoid Ass'y
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Qty.
Part Numbers
E318-Y06M1-28-61 1
1
SO-NB-G35
1
SO-NB-P28
2
SO-NB-P28
1
SO-NB-P26
1
SO-NB-P16
1
SO-NB-P14
1
SO-NB-P9
2
SO-NB-P6
1
SO-NA-A016

EFG -06-250- -51/5190

EFCG
23 21 34 22 18 19 39 20

32 42 46 49 30 38 17

12 40 47 11 10

47 40 12

38
29

Detail of Section C-C

C
C

35

List of Seal Kits

33
16

13 44

45 44 34 24

31 43

41 36 15 37 14 38 41

With Check Valve (EFCG-06)


5

48 28

39
27
26

Detail of "A"

Section B-B
Note: The connector assembly GDM-211-B-11 (Item 32) is not included in the solenoid
assembly.
Note: When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for solenoid ass'y is included in the seal kit.
For the detail of the solenoid ass'y seals, see the Catalogue No. Pub. EC-1302.

No.20

Model Numbers

Seal Kit Numbers

EFG-06-250--51
EFCG-06-250--51

KS-EFG-06-51
KS-EFCG-06-51

List of Seals and Solenoid Ass'y


Item
31
33
34
35
36
37
38
39
40
41

Name of Parts
Solenoid Ass'y
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Qty.
Part Numbers
E318-Y06M1-28-61 1
1
SO-NA-P21
3
SO-NB-P50
1
SO-NB-P46
1
SO-NB-P36
2
SO-NB-P34
4
SO-NB-P32
1
SO-NA-P21
2
SO-NB-P10
3
SO-NB-P9

Two O-rings are required for the EFCG.

E Series
10 Series Flow Control (and Check) Valves PROPORTIONAL
EFG/EFCG-03/06
CONTROLS
Interchangeability between Current and New Design
Interchangeability between Current and New Design
EFG/EFCG-03/06 series valves have changed model from 50 to 51 design in line with the model change of solenoid
ass'y (E318).
Specifications and characteristics
No change in specifications and characteristics between current and new design.
Mounting Interchangeability
There is an interchangeability in the mounting dimensions between current and new design, however, note that
because of improvements made on the solenoids, the overall shapes have been changed as shown below.

Current: Design 50

New: Design 51

Air Vent
3(.12) Hex. Soc.
Adaptor
22(.87) Hex.

Manual Adj. Screw


3(.12) Hex. Soc.

Manual Adj. Screw


3(.12) Hex. Soc.
See EDG-01 (Catalogue No. Pub. EC-1302)
for the details of the solenoid ass'y.

Air Vent
3(.12) Hex. Soc.
3 Places

See EDG-01
(Catalogue No. Pub. EC-1302)
for the details of the solenoid ass'y.

DIMENSIONS IN
MILLIMETRES (INCHES)

No.21

E Series
40 -10 Series Flow Control and Relief Valves PROPORTIONAL
EFBG-03/06/10 (3/8, 3/4, 1-1/4), Sub-plate Mounting
CONTROLS
Specifications / Model Number Designation

Specifications
Model No.

EFBG-03
-125--17

EFBG-06
-250--17

EFBG-10
-500--17

24.5 (3550)

24.5 (3550)

24.5 (3550)

L /min (U.S.GPM)

125 (33)

250 (66)

500 (132)

Metred Flow Adjustment Range


L /min (U.S.GPM)
Rated Current
Coil Resistance
Differential Pressure
MPa (PSI)

1-125
(.26-33)

2.5-250
(.66-66)

5-500
(1.32-132)

600 mA
43.5

580 mA
43.5

700 mA
43.5

0.6 (85)

0.7 (100)

0.9 (130)

Less than 7%
Less than 1%

Less than 7%
Less than 1%

Less than 7%
Less than 1%

C : 1.4-13.7
(205-2000)
H : 1.4-20.6
(205-3000)

C : 1.5-13.7
(220-2000)
H : 1.5-20.6
(220-3000)

C : 1.6-13.7
(230-2000)
H : 1.6-20.6
(230-3000)

Rated Current

C : 750 mA
H : 750 mA

C : 690 mA
H : 730 mA

C : 690 mA
H : 690 mA

Coil Resistance
Hysteresis
Repeatability

10
Less than 3%
Less than 1%

Description
Max. Operating Pressure
MPa (PSI)

Flow Controls

Max. Flow

Hysteresis
Repeatability
2

Pressure Controls

Pres. Adj. Range

MPa (PSI)

Approx. Mass

kg (lbs.)

10
10
Less than 3%
Less than 3%
Less than 1%
Less than 1%
Refer to page 24 to 26

1. The specifications for pressure controls are applied to models with proportional pilot relief
valve. (Ex. EFBG-03-125-C--17)
2. The maximum pressure adjustment range of the models without proportional pilot relief valves
is 24.5 MPa (3550 PSI).

Model Number Designation

EFB

-03

-125

-C

-17

Series
Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

Proportional Pilot Relief Valve


Pressure Adjustment Range

Design
Number

Design
Standards

EFB :
Proportional
ElectroHydraulic
Flow Control
and Relief
Valve

G:
Sub-plate
Mounting

03

125 : 125 ( 33)

06

250 : 250 ( 66)

10

500 : 500 ( 132)

17

C, H :
See Specifications

17

None :
Without Proportional
Pilot Relief Valve

Refer to

17

Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Graphic Symbols
A

A
Y

O
M

O
M

V
T

With Proportional Pilot Relief Valve

No.22

Without Proportional Pilot Relief Valve

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Sub-plate / Instructions / Others


Attachment
Mounting Bolts
Socket Head Cap Screw

Valve Model
Numbers

Japanese Std. "JIS" and European Design Std.


M10 100 Lg.
M16 130 Lg.
M20 130 Lg.

EFBG-03
EFBG-06
EFBG-10

N. American Design Std.


3/8-16 UNC 4 Lg.
5/8-11 UNC 5 Lg.
3/4-10 UNC 5 Lg.

Qty.
4
4
4

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
the Catalogue No. Pub. EC-1305).
Model Numbers
EFBG-03-125-17/1790
EFBG-06-250-17/1790
EFBG-10-500-17/1790
03
EFBG-06--C
H-17/1790
10

Power Amplifier Model Numbers


For Flow Control
AME-D-S--32
AME-DF-S--22
AME-T-S--22

For Pres. Control

AME-D2-H1--12

Sub-plate
Valve
Model
Numbers
EFBG-03
EFBG-06

EFBG-10

Japanese Standard "JIS"


Sub-plate
Model Numbers

European Design Standard

N. American Design Standard

Approx. Mass
kg (lbs.)

Thread Size

Sub-plate
Model Numbers

Thread Size

Sub-plate
Model Numbers

Thread Size

EFBGM-03Y-10

Rc 3/4

EFBGM-03Y-1080

3/4 BSP.F

EFBGM-03Y-1090

3/4 NPT

EFBGM-03Z-10

Rc 1

EFBGM-03Z-1080

1 BSP.F

EFBGM-03Z-1090

1 NPT

EFBGM-06X-10

Rc 1

EFBGM-06X-1080

1 BSP.F

EFBGM-06X-1090

1 NPT

12.5 (27.6)

EFBGM-06Y-10

Rc 1-1/4

EFBGM-06Y-1080

1-1/4 BSP.F

EFBGM-06Y-1090

1-1/4 NPT

16 (35.3)

EFBGM-10Y-10

1-1/2, 2
Flange
Mounting

EFBGM-10Y-1080

1-1/2, 2
Flange
Mounting

EFBGM-10Y-1090

1-1/2, 2
Flange
Mounting

37 (81.6)

6 (13.2)

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should
have a good machined finish.
When ordering the EFBGM-10Y, see Type F3 Pipe Flange Kits on the Catalogue No. Pub. EC-3001 and order an appropriate pipe flange kit also.

Instructions
Drain Back Pressure
Check that the drain back pressure dose not exceed 0.2 MPa (29 PSI).
When Relief Valve Passing Flow Rate is Low in Pressure Control State
To avoid preselected pressure instability, use a passing flow rate of 10 L/min (2.6 U.S.GPM) or higher for nominal sizes
03 and 06 or 15 L/min (4.0 U.S.GPM) or higher for nominal size 10.
Further, check that the tank-line back pressure does not exceed 0.5 MPa (70 PSI).
Safety Valve Pressure Setting
The pressure of the safety valve is preset at the value equal to the upper limit of the pressure adjustment range plus
2 MPa (290 PSI). Please adjust the pressure of the valve so preset to meet the pressure to be used actually.
To lower the pressure setting, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure
to tighten the lock nut.

No.23

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-03

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-03-125-C-17/1790
H

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Air Vent
3 (.12) Hex. Soc.
188
(7.40)

Pressure Adj. Screw


for Safety Valve
3 (.12) Hex. Soc. INC.

61.7
(2.43)

35.5
(1.40)
14.2
(.56)

Inlet Port "P"


37.7
(1.48)

Fully Extended
216(8.50)
100.6
39
(3.96)
(1.54)

61.8
(2.43)
101.6
(4.00)
130
(5.12)

38
(1.50)

Lock Nut 10 (.39) Hex.

11.7
(.46)

The direction can


be altered to every
90 degree angles

50.8
(2.00)
101.6
(4.00)
125
(4.92)

11 (.43) Dia. Through


17.5 (.69) Dia. Spotface
4 Places
Tank Port "T"
Manual Flow Adjustment
M4 Thd. (Internal Thd.)
INC.

Vent Port "V"

Outlet Port "A"


Drain Port "Y"

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Connector

Connector
The direction can be altered
to 90 degree angles.

80
(3.15)

Air Vent 3 (.12) Hex. Soc.


3 Places
39
(1.54)

Manual Pressure Adj. Screw


3 (.12) Hex. Soc.

Mounting Surface
(O-Rings Furnished)

6
(.24)

DIMENSIONS IN
MILLIMETRES (INCHES)

85
(3.35)
125
(4.92)

110.5
(4.35)
41
57.5
(1.61) (2.26)

212
(8.35)

INC.

Two Locating Pins


6(.24) Dia.

Manual flow adjustment can be done by screwing for example an


M4 20L screw in the M4 thread or pushing in a rod etc. there.

Models without Proportional Pilot Relief Valve


EFBG-03-125-17/1790

Approx. Mass ...... 16 kg


(35.3 lbs.)
174
(6.85)
47.7
(1.88)

Fully Extended
102.5
(40.4)

29.7
(1.17)

Lock Nut 10 (.39) Hex.


Pressure Adjustment
Screw for Safety Valve
3(.12) Hex. Soc.
INC.

For other dimensions, please refer to the models with proportinal pilot relief valve.

No.24

Approx. Mass ...... 14 kg


(30.9 lbs.)

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-06

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-06-250-C-17/1790
H
247
(9.72)

Lock Nut
10(.39) Hex.
Fully
Extended
32.5
(1.28)

67
(2.64)

Inlet Port "P"


43
(1.69)

20.3
(.80)

Pressure Adj. Screw


for Safety Valve
3(.12) Hex. Soc. INC.

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

82
(3.23)
133.4
(5.25)
174
(6.85)

39
(1.54)

106.2
(4.18)

Fully Extended
216(8.50)

Air Vent
3 (.12) Hex. Soc.

The direction can


be altered to every
90 degree angles.

17
(.67)

73
(2.87)
146.1
(5.75)
180
(7.09)

Outlet Port "A"


Drain Port "Y"

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Tank Port "T"


Manual Flow Adjustment
M4 Thd. (Internal Thd.)

80
(3.15)

Connector
The direction can be altered
to 90 degree angles.

DIMENSIONS IN
MILLIMETRES (INCHES)

Mounting Surface
(O-Rings Furnished)
INC.

Two Locating Pins


16 (.63) Dia.

245
(9.65)

7
(.28)

107
(4.21)
157
(6.18)

131.5
(5.18)
62
57.5
(2.44) (2.26)

Air Vent
3 (.12) Hex. Soc.
3 Places

Manual Pressure
Adjustment Screw
3(.12) Hex. Soc.

INC.

Vent Port "V"

39
(1.54)

Connector

17.5(.69) Dia. Through


26(1.02) Dia. Spotface
4 Places

Approx. Mass ...... 30 kg (66.2 lbs.)

Manual flow adjustment can be done by screwing for example an M4 20L screw in the M4 thread or
pushing in a rod etc. there.

Models without Proportional Pilot Relief Valve


EFBG-06-250-17/1790

238
(9.37)
58
(2.28)

Fully Extended
119(4.69)

43
(1.69)

Lock Nut
10(.39) Hex.

Manual Pressure Adj. Screw


3(.12) Hex. Soc.

INC.

Approx. Mass ...... 28 kg (61.7 lbs.)


For other dimensions, please refer to the models with Proportional Pilot Relief Valve.

No.25

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-10

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-10-500-C-17/1790
H
Pressure Adj. Screw

Inlet Port "P"

INC.
315
(12.40)

Lock Nut
10(.39) Hex.

23
(.91)

116.5
(4.59)

115
(4.53)
177.8
(7.00)
224
(8.82)

22.5
(.89)

48.5
(1.91)

39
(1.54)
The direction can
be altered to every
90 degree angles.

23.5
(.93)

21.5(.85) Dia. Through


32(1.26) Dia. Spotface
4 Places

98.5
(3.88)
196.9
(7.75)
244
(9.61)

Tank Port "T"


Manual Flow Adjustment
M4 Thd. (Internal Thd.)

Outlet Port "A"

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Drain Port "Y"

Connector
The direction can be altered
to 90 degree angles.

Connector

70
(2.76)

107
(4.21)
187
(7.36)

57.5
(2.26)
150
(5.91)

219.5
(8.64)

INC.

Air Vent
3 (.12) Hex. Soc.
3 Places

Mounting Surface
(O-Rings Furnished)

DIMENSIONS IN
MILLIMETRES (INCHES)

39
(1.54)

80
(3.15)
Manual Pressure
Adjustment Screw
3(.12) Hex. Soc.

INC.

Vent Port "V"

Two Locating Pins


18(.71) Dia.

274
(10.79)

Fully Extended
216(8.50)

Air Vent
3 (.12) Hex. Soc.

M8 Thd. 16(.63) Deep


2 Places
For Eye Bolts

73.5
(2.89)

10
(.39)

for Safety Valve


3(.12) Hex. Soc.

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Approx. Mass ...... 60 kg (132 lbs.)


Manual adjustment can be done by screwing for example an M4 20 L screw in the M4 thread or pushing
in a rod etc. there.

Models without Proportional Pilot Relief Valve


EFBG-10-500-17/1790

301
(11.85)
59.5
(2.34)

Fully Extended
145.5(5.73)

41.5
(1.63)

Lock Nut
10(.39) Hex.

Pressure Adj. Screw


for Safety Valve
3(.12) Hex. Soc.

INC.

Approx. Mass ...... 58 kg (128 lbs.)


For other dimensions, please refer to the models with Proportional Pilot Relief Valve.

No.26

E Series
Sub-plate for
40 -10 Series Flow Control and Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-plate
EFBGM-03Y/03Z-10/1080/1090
11.7
(.46)
0.8
(.03)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

23(.91) Dia.
3 Places

101.6(4.00)
77.8(3.06)
50.8(2.00)

7(.28) Dia.
7(.28) Deep
2 Places

23.8(.94)

12.7
28.6 (.50)
(1.13)
88.9(3.50)

59(2.32)
20(.79)

80(3.15)

100(3.94)

14.2
(.56)
130(5.12)

101.6(4.00)

125(4.92)
102.4(4.03)

22.2
(.87)
"E" Dia.
"B" Thd.(From Rear)
11
(.43)

95.3(3.75)

"C" Thd. "D" Deep


4 Places

"A" Thd.
(From Rear)
3 Places

39.2
(1.54)

Sub-plate
Model Numbers

106.8(4.20)
146(5.75)

EFBGM-03Y-10
EFBGM-03Z-10
EFBGM-03Y-1080
EFBGM-03Z-1080
EFBGM-03Y-1090
EFBGM-03Z-1090

"B" Thd.

168(6.61)

20
(.79)

40
(1.57)

6(.24) Dia.

mm (in.)
Thread Size
"A" Thd. "B" Thd. "C" Thd.
D
E
Rc 3/4
11
Rc 1/4
(.43)
Rc 1
M10
18 (.71)
3/4 BSP.F
11.7
1/4 BSP.F
(.46)
1 BSP.F
3/4 NPT
11
1/4 NPT 3/8-16 UNC 21 (.83)
(.43)
1 NPT

DIMENSIONS IN
MILLIMETRES (INCHES)

EFBGM-06X/06Y-10/1080/1090
29(1.14) Dia.
3 Places

20.3
(.80)
133.4(5.25)

107(4.21)

"E" Thd.
3 Places (From Rear)

33(1.30)
19(.75)

41.3(1.63)

17(.67) Dia. 10(.39) Deep


2 Places

85.7(3.37)

B
16(.63)

126(4.96)

174(6.85)

24
(.94)

17.5(.69) Dia. Through


26(1.02) Dia. spotface
4 Places

180(7.09)
146.1(5.75)
144.5(5.69)
118.1(4.65)
73.1(2.88)
28.1(1.11)
1.6(.06)

12.7(.50)

17
(.67)

3.7(.15)

"J" Thd. "K" Deep


4 Places

212(8.35)

6.2(.24) Dia.
"H" Thd. (From Rear)

250(9.84)

"L" Dia.
"F" Thd. (From Rear)

Sub-plate
Model No.
EFBGM-06X-10
EFBGM-06Y-10
EFBGM-06X-1080
EFBGM-06Y-1080
EFBGM-06X-1090
EFBGM-06Y-1090

"E" Thd.
Rc 1
Rc 1-1/4
1 BSP.F
1-1/4 BSP.F
1 NPT
1-1/4 NPT

Dimensions
mm (in.)
B
C
D
EFBGM-06X 103.3 (4.07) 45 (1.77)
35 (1.38)
EFBGM-06Y 95 (3.74)
60 (2.36)
40 (1.54)
Sub-plate
Model No.

Thread Size
"F" Thd.
"H" Thd.

"J" Thd.

mm (in.)
K
L
30
14
(1.18) (.55)

Rc 3/8

Rc 1/4

M 16

3/8 BSP.F

1/4 BSP.F

M 16

30
(1.18)

15.2
(.60)

3/8 NPT

1/4 NPT

5/8-11 UNC

35
(1.38)

14
(.55)

No.27

E Series
Sub-plate for
40 -10 Series Flow Control and Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing
EFBGM-10Y-10/1080/1090

DIMENSIONS IN
MILLIMETRES (INCHES)
244(9.61)
23.5
(.93)

"D" Thd. "F" Deep


4 Places

196.9(7.75)

"E" Thd. "F" Deep


12 Places (From Rear)

162(6.38)

21.5(.85) Dia. Through


32(1.26) Dia. spotface
4 Places

20(.79) Dia. 15(.59) Deep


2 Places
23
(.91)

36.1
(1.42)

98.5
(3.88)
73
1.6
35
(.06) (1.38) (2.87)

43.5
(1.71)

73
(2.87)

29
(1.14)
224
(8.82)

177.8(7.00)
144.5(5.69)
119(4.69)
55.5
(2.19) 17.5
(.69)

250(9.84)

43.5(1.71) Dia.
3 Places

198.4(7.81)

48(1.89) Dia.
3 Places (From Rear)

73
(2.87)

73
(2.87)
72
(2.83)

"H" Dia.
"B" Thd. (From Rear)
212(8.35)

25
(.98)

284(11.18)
334(13.15)

50
(1.97)

80
(3.15)

6.2(.24) Dia.
"C" Thd. (From Rear)

Sub-plate
Model No.
EFBGM-10Y-10
EFBGM-10Y-1080
EFBGM-10Y-1090

"B" Thd.
Rc 3/8
3/8 BSP.F
3/8 NPT

Sub-plate
Model No.
EFBGM-10Y-10
EFBGM-10Y-1080
EFBGM-10Y-1090

No.28

Thread Size
"D" Thd.
"C" Thd.
Rc 1/4
M20
1/4 BSP.F
1/4 NPT 3/4-10 UNC
mm (in.)
F

H
14 (.55)
32 (1.26)
15.2 (.60)
34 (1.34) 14 (.55)

"E" Thd.
M16
5/8-11 UNC

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Step Response
These characteristics have been obtained by measuring on each valve.
Therefore, they may vary according to a hydraulic circuit to be used.
Flow Controls

EFBG-06

100

20
15

80

10
5
0

40

70

0.1s

60

Flow Rate

Flow Rate

25

EFBG-10

U.S.GPM L /min
80
300
250

60
50

200

40

150

30

0.1s

100

20
0

400

75

300

50

200

25

100

50

10

Time

100

Step Signal

20

Step Signal

U.S.GPM L /min
600
150
500
125

Flow Rate

EFBG-03
U.S.GPM L /min
160
40
140
35
120
30

0.1s

Step Signal

Time

Time

Pressure Controls

EFBG-03

EFBG-06

EFBG-10

MPa
22

PSI
3000

3000

2500

14

2000
1500

EFBG-03-125-C
0.2s

10

1000

18

Step Signal

Pressure

Pressure

2500

3000

EFBG-03-125-H

18

MPa
22

PSI

2000

14

1500

10

1000

EFBG-10-500-H

EFBG-06-250-H
18

2500

EFBG-06-250-C
0.2s

Step Signal

Pressure

MPa
22

PSI

2000

14

1500

10

1000

EFBG-10-500-C
0.2s
Step Signal

Time

Time

Time

Input Current vs. Flow

EFBG-03

EFBG-06
U.S.GPM L /min
80

15

50

40

150

50

10
0
0

0
0

100 200 300 400 500 600

Input Current mA

PSI MPa
25
3500

1500

3000

15

Pressure

Pressure

2500
2000

EFBG-03-125-C

5
500
200

400 600 800 1000

Input Current mA

200

25

100
0
0

PSI MPa
25
3500
3000

20 EFBG-06
-250-H

2000

15

1000
5

EFBG-06-250-C

EFBG-10

20 EFBG-10
-500-H

2500
2000
1500

10

100 200 300 400 500 600 700

Input Current mA

EFBG-06

500
0
0

50

100 200 300 400 500 600 700

2500

1500

10

1000

PSI MPa
25
3500

20
EFBG-03
-125-H

300

Input Current mA

Input Current vs. Pressure


EFBG-03
3000

75

100

20

25

400

100

200

50

30

10
5

250

60

Flow Rate

75

500

125

Pressure

20

U.S.GPM L /min

300

70

100

25

Flow Rate

Flow Rate

U.S.GPM L /min
35
125
30

EFBG-10

15
10

1000

EFBG-10-500-C

5
500

0
0

200 400 600 800 1000

Input Current mA

0
0

200

400 600 800 1000

Input Current mA

No.29

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-03/06

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-03-125--17/1790
EFBG-06-250--17/1790

48
18 37 38 17 2 25 53 35 6 33 7

52 31

23

25

28

20

46

16

49

15
21

A
A

27

32

41

42

11

43

24

44

26

45

39

49 47

19 36 29 34

22
40
41
32

50

15

10

16

13 51 12 30 14

28

Detail of "B"

17 23 37 38 18
48

Without Proportional
Pilot Relief Valve

Section A-A
List of Seals
Item

Name of Parts

23
24
25
26
27
28
29
30
31
32

O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Part Numbers
EFBG-06

EFBG-03
SO-NA-P6
SO-NB-G30
SO-NB-P32
SO-NB-P28

CAUTION
Qty.

SO-NA-P6
SO-NB-P44
SO-NB-P42
SO-NB-P32
SO-NB-P34
SO-NB-P14
SO-NB-P11
SO-NA-P10
SO-NB-P9
SO-NB-A013

SO-NB-P14
SO-NB-P11
SO-NB-P9
SO-NB-A013

1
1
2
3
1
1
1
1
1
1

When making replacement of seals, please do it


carefully after reading through the relevant
instructions in the Operator's Manual.

List of Seal Kits


Model Numbers

Seal Kit Numbers

EFBG-03-125-17
EFBG-03-125-C/H-17
EFBG-06-250-17
EFBG-06-250-C/H-17

KS-EFBG-03-17
KS-EFBG-03-C-17
KS-EFBG-06-17
KS-EFBG-06-C-17

Solenoid Ass'y and Safety valves


Valve Model Numbers
EFBG-03-125-C/H-17/1790
EFBG-06-250-C/H-17/1790

47 Solenoid Ass'y Model No.

46 Solenoid Ass'y Model No.

48 Safety Valve Model No.

E321-45-20

SB1094-2002

E318-Y06M2-05-61

EFBG-03-125-17/1790
EFBG-06-250-17/1790
Note: The connector assembly GDM-211-B-11 is not included in the solenoid assembly.
When ordering seals, please specify the seal kit number from the table above.
In addition to the above o-rings, o-rings for solenoid ass'y 46 and 47 are included in the seal kit.
For the details of seals for solenoid ass'y 46 , see page12 and for solenoid ass'y 47 see Catalogue No. Pub. EC-1302.

No.30

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-10

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-10-500--17/1790
29 32 21 35 6

7 33 3

4 21 5 30

42
45
45

22

31

43

9
11
8
A

10
20
23
39

2 32 27 32 33 36 26 34

Section A-A
Detail of Safety Valve
(Item 44)
28 15 25 19 37 38

41

29 2

14
12
B

24
13
44

Detail of "C"

Section B-B

Without Proportional
Pilot Relief Valve

List of Seals and Solenoid Ass'y


Item
19
20
21
22
23
24
25
26
27
28
42

Name of Parts
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Solenoid Ass'y

16 18 17

40

Part Numbers
SO-NA-P6
SO-NB-G60
SO-NB-G55
SO-NB-P50
SO-NB-P48
SO-NA-P10
SO-NB-P14
SO-NB-P11
PO-NB-P11
SO-NB-A013
E321-45-20

Qty.
1
1
2
1
3
1
1
1
1
1
1

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

List of Seal Kits


Model Numbers
EFBG-10-500-17
EFBG-10-500-C/H-17

Seal Kit Numbers


KS-EFBG-10-17
KS-EFBG-10-C-17

Note: The connector assembly GDM-211-B-11 is not included in the solenoid assembly.
When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for Pilot Valve and solenoid ass'y are included in the seal kit.

Pilot Valves and Safety Valves


Valve Model Numbers

43 Proportional Pilot Relief Valve Model Numbers

44 Safety Valve Model Numbers

SB1094-2002

EFBG-10-500-17/1790
EFBG-10-500-C-17/1790

EDG-01V-C-1-P18T17-5103

EFBG-10-500-H-17/1790

EDG-01V-H-1-PNT13-5103

Note: Refer to Catalogue No.Pub.EC-1302 of the Proportional Pilot Relief Valve for details of the pilot valve.

No.31

E Series
40 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
Model changes have been made from 15 to 17-design in the EFBG-03/06 because of changes in the pilot valve buildingin method and in EFBG-10 because of model changes in the pilot valve.
Specification and Characteristics
No changes in specifications and characteristics between current and new design.
Interchangeability in Installation
EFBG-03/06
There is an interchangeability in installation. However, the method of building in the pilot valve has been changed,
bringing about changes in the appearance shapes and dimensions as shown below.
Current : Design 15
Fully Extended A
B

Solenoid Ass'y
E321-45-10

New : Design 17
Fully Extended A

Air Vent

Solenoid Ass'y
E321-45-20

Manual Pressure
Adj. Screw

Cable Deperture

Pressure Adj. Screw


for Safety Valve

Cable Deperture

See EDG-01 (Catalogue No. Pub. EC-1302)


for the details of the solenoid ass'y

Pressure Adj. Screw


for Safety Valve

Manual Pressure Adj. Screw

(Current)
(New)
(Current)
(New)

Model Numbers
EFBG-03-125--17/1790
EFBG-03-125--15/1590
EFBG-06-250--17/1790
EFBG-06-250--15/1590

Air Vent
3 Places

See EDG-01 (Catalogue No. Pub. EC-1302)


for the details of the solenoid ass'y

A
216 (8.50)
217 (8.54)
216 (8.50)
217 (8.54)

B
38 (1.50)
47 (1.85)
32.5 (1.28)
39.5 (1.56)

C
23.5 (.93)
25.7 (1.01)
3 (.12)
5.5 (.22)

D
164 (6.46)
164.3 (6.47)
196 (7.72)
196.3 (7.73)

E
212 (8.35)
213 (8.39)
245 (9.65)
245 (9.65)

F
41 (1.61)
101.5 (4.00)
62 (2.44)
130 (5.12)

EFBG-10
The mounting surface are interchangeable. Only the appearance shapes are different as follows;
Current : Design 15
Solenoid Ass'y
E321-45-10

Pressure Adj. Screw


for Safety Valve

New : Design 17

Air Vent

Manual Pressure
Adj. Screw

Solenoid Ass'y
E321-45-20

Manual Pressure
Adj. Screw

Pressure Adj. Screw


for Safety Valve

Air Vent
3 Places

Proportional Pilot Valve


EDG-01-50Design

See EDG-01
(Catalogue No. Pub. EC-1302)
for the details of the solenoid ass'y

Proportional Pilot Valve


EDG-01-51Design

DIMENSIONS IN
MILLIMETRES (INCHES)

No.32

See EDG-01
(Catalogue No. Pub. EC-1302)
for the details of the solenoid ass'y

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03/06/10 (3/8, 3/4, 1-1/4), Sub-plate Mounting

PROPORTIONAL
CONTROLS

Specifications

Specifications
Model Numbers

EFBG-03
-125---61

EFBG-06
-250---61

EFBG-10
-500---51

24.5 (3550)

24.5 (3550)

24.5 (3550)

L /min (U.S.GPM)

125 (33)

250 (66)

500 (132)

Metred Flow Adjustment Range


L /min (U.S.GPM)
Min. Pilot Pressure
MPa (PSI)
at Normal
Pilot Flow
L /min (U.S.GPM) at Transition
Rated Current
Coil Resistance
Differential Pressure
MPa (PSI)

1-125
(.26-33)

2.5-250
(.66-66)

5-500
(1.32-132)

1.5 (220)
1 (.26)
3 (.79)
800 mA
10

1.5 (220)
1 (.26)
4 (1.06)
750 mA
10

1.5 (220)
1 (.26)
6 (1.59)
900 mA
10

0.7 (100)

0.7 (100)

0.9 (130)

Less than 3%
Less than 1%

Less than 3%
Less than 1%

Less than 3%
Less than 1%

C : 1.4-15.7
(200-2275)
H : 1.4-24.5
(200-3550)

C : 1.4-15.7
(200-2275)
H : 1.4-24.5
(200-3550)

C : 1.5-15.7
(220-2275)
H : 1.5-24.5
(220-3550)

C : 890 mA
H : 930 mA

C : 820 mA
H : 880 mA

C : 800 mA
H : 900 mA

Description
Max. Operating Pressure
MPa (PSI)

Flow Controls

Max. Flow

Pressure Controls

Hysteresis
Repeatability
2

Pres. Adj. Range

MPa (PSI)

Rated Current

10
Less than 3%
Less than 1%

Coil Resistance
Hysteresis
Repeatability
Approx. Mass

kg (lbs.)

10
10
Less than 3%
Less than 3%
Less than 1%
Less than 1%
Refer to page 35 to 37

1. The specifications for pressure controls are applied to models with proportional pilot relief
valve. (Ex. EFBG-03-125-C--61)
2. The maximum pressure adjustment range of the models without proportional pilot relief
valves is 24.5 MPa (3550 PSI).

Graphic Symbols
With Proportional Pilot Relief Valve
External Pilot

Without Proportional Pilot Relief Valve


External Pilot

Internal Pilot

Internal Pilot

A
Y

X
O
M

X
O
M

O
M

O
M

V
T

No.33

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Model Number Designation / Others


Model Number Designation

EFB

-03

-125

-C

-E

-61

Series
Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

Proportional Pilot Relief


Valve Pressure Adj. Range

Pilot
Connection

Design
Number

Design
Standards

EFB :
Proportional ElectroHydraulic Flow
Control and Relief
Valve

C, H :
See Specifications
None :
Without Proportional
Pilot Relief Valve

None :
Internal Pilot

61

G:
Sub-plate
Mounting

03

125 : 125 ( 33)

06

250 : 250 ( 66)

10

500 : 500 ( 132)

61

E:
External Pilot

Refer to

51

Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Attachment
Mounting Bolts
Socket Head Cap Screw

Valve Model
Numbers

Japanese Std. "JIS" and European Design Std.

N. American Design Std.

EFBG-03
EFBG-06
EFBG-10

M10 65 Lg.
M16 100 Lg.
M20 130 Lg.

3/8-16 UNC 2-1/2 Lg.


5/8-11 UNC 4 Lg.
3/4-10 UNC 5 Lg.

Qty.
4
4
4

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see Catalogue
No. Pub. EC-1305).
Power Amplifier Model Numbers

Model Numbers
EFBG-03-125-(E)-61/6190
EFBG-06-250-(E)-61/6190
EFBG-10-500-(E)-51/5190
EFBG-03-125-C/H-(E)-61/6190
EFBG-06-250-C/H-(E)-61/6190
EFBG-10-500-C/H-(E)-51/5190

For Pres. Control

For Flow Control


AME-D-10--20
AMN-D-10 (For DC Power Supply)
AME-D2-1010--10

Sub-plate
Valve
Model
Numbers
EFBG-03
EFBG-06

EFBG-10

Japanese Standard "JIS"

European Design Standard

N. American Design Standard

Approx. Mass
kg (lbs.)

Sub-plate
Model Numbers

Thread Size

Sub-plate
Model Numbers

Thread Size

Sub-plate
Model Numbers

Thread Size

EFBGM-03Y-20

Rc 3/4

EFBGM-03Y-2080

3/4 BSP.F

EFBGM-03Y-2090

3/4 NPT

EFBGM-03Z-20

Rc 1

EFBGM-03Z-2080

1 BSP.F

EFBGM-03Z-2090

1 NPT

EFBGM-06X-20

Rc 1

EFBGM-06X-2080

1 BSP.F

EFBGM-06X-2090

1 NPT

12.5 (27.6)

EFBGM-06Y-20

Rc 1-1/4

EFBGM-06Y-2080

1-1/4 BSP.F

EFBGM-06Y-2090

1-1/4 NPT

16 (35.3)

EFBGM-10Y-20

1-1/2, 2
Flange
Mounting

EFBGM-10Y-2080

1-1/2, 2
Flange
Mounting

EFBGM-10Y-2090

1-1/2, 2
Flange
Mounting

37 (81.6)

6 (13.2)

Sub-plates are available. Specify the sub-plate model number from the table above. When sub-plates are not used, the mounting surface should
have a good machined finish.
When ordering the EFBGM-10Y, see Type F3 Pipe Flange Kits on the Catalogue No. Pub. EC-3001 and order an appropriate pipe flange kit also.

Instructions
Drain Back Pressure
Check that the drain back pressure dose not exceed 0.2 MPa (29 PSI).
When Relief Valve Passing Flow Rate is Low in Pressure Control State
To avoid preselected pressure instability, use a passing flow rate of 15 L /min (4.0 U.S.GPM) or higher.
Further, check that the tank-line back pressure dose not exceed 0.5 MPa (70 PSI).
Safety Valve Pressure Setting
The pressure of the safety valve is preset at the value equal to the upper limit of the pressure adjustment range plus
2 MPa (290 PSI). Please adjust the pressure of the valve so preset to meet the pressure to be used actually.
To lower the pressure setting, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure
to tighten the lock nut.

No.34

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve

Outlet Port "A"


12.8
(.50)

50.8
33.3
(2.00)
(1.31)
57.5
(2.26)
101.6
(4.00)
125
(4.92)

Vent Port "V"

11.7
(.46)

Pilot Pressure Port "X"

11(.43) Dia. Through


17.5(.69) Dia. C'Bore
4 Places

Inlet Port "P"

Tank Port "T"


Drain Port "Y"

Manual Pressure Adj. Screw


3(.12) Hex. Soc.

2
(.08)

14.2
(.56)

130
(5.12)
101.6
(4.00)
94.8
(3.73)
61.8
(2.43)

132
(5.20)

EFBG-03-125-C-(E)-61/6190
H

Manual Flow Adj. Screw


3(.12) Hex. Soc.

INC.

INC.

View Arrow Z

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Models without
Proportional Pilot Relief Valve

EFBG-03-125-(E)-61/6190
Air Vent
3 (.12) Hex. Soc.
3 Places

Air Vent
3 (.12) Hex. Soc.
3 Places

39
(1.54)

Pressure Adj. Screw


for Safety Valve
3(.12) Hex. Soc.

59
(2.32)
48.2
(1.90)

171.2
(6.74)

Fully Extended
161(6.34)

248.5
(9.78)

INC.
Pressure Adj. Screw
for Safety Valve
3(.12) Hex. Soc.

6
(.24)

Lock Nut
10(.39) Hex.

INC.

Lock Nut
10(.39) Hex.

Two Locating Pins


6 (.24) Dia.

Mounting Surface
(O-Rings Furnished)

Approx. Mass ...... 14 kg (30.9 lbs.)

For other dimensions, please refer to the models with


Proportional Pilot Relief Valve.

DIMENSIONS IN
MILLIMETRES (INCHES)

Approx. Mass ...... 13.3 kg (29.3 lbs.)

No.35

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-06

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-06-250-C-(E)-61/6190
H

17.5(.69) Dia. Through


26(1.02) Dia. Spotface
4 Places

Inlet Port "P"

Manual Pressure
Adj. Screw
3(.12) Hex. Soc.

Drain Port "Y"


Air Vent
3 (.12) Hex. Soc.
3 Places

54
57.5
(2.13)
(2.26)
73.1
(2.88)
146.1
(5.75)
180
(7.09)

Air Vent
3 (.12) Hex. Soc.
3 Places

Tank Port "T"

17
(.67)

20.3
(.80)

174
(6.85)
133.4
(5.25)
129.7
(5.11)
85.7
(3.37)
19.7
(.78)

INC.

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Models without
Proportional Pilot Relief Valve

Pilot Pressure Port "X"

EFBG-06-250-(E)-61/6190

Vent Port "V"


Outlet Port "A"
Manual Flow Adj. Screw
3(.12) Hex. Soc.

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

39
(1.54)

Pressure Adj. Screw


for Safety Valve
3(.12) Hex. Soc.

Fully Extended
195(7.68)

77
(3.03)
76
(2.99)
8
(.31)

Lock Nut
10(.39) Hex.

INC.

Lock Nut
10(.39) Hex.

289.5
(11.40)
212.2
(8.35)

INC.
Pressure Adj. Screw
for Safety Valve
3(.12) Hex. Soc.

INC.

Mounting Surface
(O-Rings Furnished)

Two Locating Pins


16(.63) Dia.

Approx. Mass ...... 22 kg (48.5 lbs.)

For other dimensions, please refer to the models with


Proportional Pilot Relief Valve.
Approx. Mass ...... 21.3 kg (47.0 lbs.)

No.36

DIMENSIONS IN
MILLIMETRES (INCHES)

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-10

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-10-500-C-(E)-51/5190
H
Sling Fitting
2 Places

21.5 (.85) Dia. Through


32 (1.26) Dia. Spotface
4 Places
Inlet Port "P"

Drain Port "Y"


Air Vent 3 (.12) Hex. Soc.
3 Places
23.6
(.93)

21
(.83)

Lock Nut 10 (.39) Hex.

57.5
(2.26)
69.5
(2.74)
98.5
(3.88)

39
(1.54)

Vent Port "V"

12
(.47)

65.4
(2.57)

Connector
The direction can be
altered to every 90 degree
angles.

Tank Port "T"

220
(8.66)
177.8
(7.00)
115
(4.53)
41
(1.61)

DIMENSIONS IN
MILLIMETRES (INCHES)

Outlet Port "A"

Manual Pressure Adj. Screw


3 (.12) Hex. Soc.

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

INC.
Manual Flow Adj. Screw
3 (.12) Hex. Soc.

Models without
Proportional Pilot Relief Valve

196.9
(7.75)
244
(9.61)

Pressure Adj. Screw


for Safety Valve
3 (.12) Hex. Soc. INC.

INC.

Pilot Pressure Port "X"

Fully Extended
226(8.90)

EFBG-10-500-(E)-51/5190

57.5
(2.26)
Pressure Adj. Screw
for Safety Valve
3 (.12) Hex. Soc.

107
(4.21)
106
(4.17)

INC.

244.2
(9.61)
321.5
(12.66)

31
(1.22)

310.5
(12.22)
241
(9.49)

Lock Nut
10 (.39) Hex.

39
(1.54)

Air Vent
3 (.12) Hex. Soc.
3 Places

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

176
(6.93)

10
(.39)

Two Locating Pins


18(.71) Dia.

Connector
The direction can be altered
to 90 degree angles.

A
Mounting Surface
(O-Rings Furnished)

Approx. Mass ...... 64 kg (141 lbs.)

For other dimensions, please refer to the models with


Proportional Pilot Relief Valve.
Approx. Mass ...... 62 kg (137 lbs.)

No.37

E Series
Sub-plate for
10 -10 Series Flow Control and Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-plate
EFBGM-03Y-20/2080/2090
03Z
125(4.92)
11.7(.46)

102.4(4.03)

Y
T

95.3(3.75)

59(2.32)

45(1.77)

P
20(.79)

80(3.15)

28.6(1.13)

12.7(.50)

14.2
(.56)

50.8(2.00)
23.8(.94)

100(3.94)

130(5.12)

7(.28) Dia. 7(.28) Deep


2 Places

77.8(3.06)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

101.6(4.00)

23(.91) Dia.
3 Places

101.6(4.00)

0.8(.03)

88.9(3.50)

"C" Thd. "D" Deep


4 Places

Sub-plate
Model Numbers

22.2(.87)

6(.24) Dia.
"B" Thd. (From Rear)
"E" Dia.
"B" Thd. (From Rear)
11
(.43)

"A" Thd.
(From Rear)
3 Places

39.2
(1.54)
106.8(4.20)

6(.24) Dia.

146(5.75)
168(6.61)

40
(1.57)

20(.79)

EFBGM-03Y-20

Rc 3/4

EFBGM-03Z-20

Rc 1

mm (in.)
D
E

Rc 1/4

EFBGM-03Y-2080 3/4 BSP.F

"B" Thd.
19(.75)

Thread Size
"B" Thd.
"C" Thd.

"A" Thd.

EFBGM-03Z-2080

1 BSP.F

EFBGM-03Y-2090

3/4 NPT

EFBGM-03Z-2090

1 NPT

18
(.71)

M10
1/4 BSP.F
1/4 NPT

3/8-16 UNC

11
(.43)
11.7
(.46)

21 11
(.83) (.43)

DIMENSIONS IN
MILLIMETRES (INCHES)

EFBGM-06X-20/2080/2090
06Y
180(7.09)

20.3
(.80)

"J" Thd.
(From Rear)

133.4(5.25)

X A Y

107(4.21)

3.7(.15)

41.3(1.63)

17(.67) Dia. 10(.39) Deep


2 Places

28.1(1.11)

16(.63)

24
(.94)

1.6
(.06)

126(4.96)

73.1(2.88)

174(6.85)

17.5(.69) Dia. Through


26(1.02) Dia. Spotface
4 Places

6.2(.24) Dia.

29(1.14) Dia.
3 Places

144.5(5.69)
118.1(4.65)

85.7(3.37)

1.9(.07)
"K" Thd. "L" Deep
4 Places

146.1(5.75)

12.7(.50)

17(.67)

33(1.30)
19
(.75)

"F" Thd.
(From Rear)
3 Places

212(8.35)
250(9.84)

"N" Dia.
"H" Thd. (From Rear)

6.2(.24) Dia.
"J" Thd. (From Rear)

Sub-plate
Model Numbers

EFBGM-06X
EFBGM-06Y

Sub-plate
Model Numbers
EFBGM-06X-20

"F" Thd.
Rc 1

EFBGM-06Y-20

Rc 1-1/4

EFBGM-06X-2080

1 BSP.F

EFBGM-06Y-2080 1-1/4 BSP.F


EFBGM-06X-2090

1 NPT

EFBGM-06Y-2090 1-1/4 NPT

No.38

A
103.3
(4.07)

Dimensions mm (in.)
B
C
D
63.3
45
35
(2.49)
(1.77)
(1.38)

E
34
(1.34)

95
(3.74)

53.3
(2.10)

39
(1.54)

Thread Size
"H" Thd. "J" Thd.
Rc 3/8

Rc 1/4

3/8 BSP.F 1/4 BSP.F


3/8 NPT

1/4 NPT

60
(2.36)

40
(1.57)

mm (in.)
"K" Thd.

M16

30
(1.18)

14
(.55)

M16

30
(1.18)

15.2
(.60)

5/8-11 UNC

35
(1.38)

14
(.55)

E Series
Sub-plate for
10 -10 Series Flow Control and Relief Valves

PROPORTIONAL
CONTROLS

Installation Drawing
EFBGM-10Y-20/2080/2090

DIMENSIONS IN
MILLIMETRES (INCHES)

244(9.61)

48(1.89) Dia.
3 Places
142(5.59)

80(3.15)

73(2.87)

49(1.93)

224
(8.82)
25
(.98)

284(11.18)
334(13.15)

73
(2.87)

73
(2.87)
72
(2.83)
212
(8.35)

"H" Dia.
6.2(.24) Dia.
"B" Thd.

Sub-plate
Model Numbers
EFBGM-10Y-20

"B" Thd.
Rc 3/8

EFBGM-10Y-2080 3/8 BSP.F


EFBGM-10Y-2090

3/8 NPT

Thread Size
"C" Thd.
"D" Thd.
Rc 1/4
1/4 BSP.F
1/4 NPT

M20
3/4-10 UNC

73
(2.87)

43.5(1.71) Dia.
3 Places

41.9(1.65)

X
Y

43.5(1.71)

6.2(.24) Dia.

"C" Thd.

50(1.97)
29
(1.14)

35
(1.38)

20(.79) Dia.
15(.59) Deep
2 Places

73
(2.87)

17.5(.69)

55.5(2.19)

162(6.38)
98.5(3.88)

115(4.53)

119(4.69)

36.1
(1.42)
144.5(5.69)

250(9.84)

177.8(7.00)

196.9(7.75)

74
(2.91)
119
(4.69)
144.5
(5.69)
177.8
(7.00)

1.6(.06)

21.5(.85) Dia. Through


32(1.26) Dia. Spotface
4 Places

"E" Thd. "F" Deep


12 Places

198.4(7.81)

7.5(.30)

23.5(.93)

23
(.91)

"D" Thd. "F" Deep


4 Places

"C" Thd.

mm (in.)
"E" Thd.

M16

32(1.26)

5/8-11 UNC 34(1.34)

H
14(.55)
15.2(.60)
14(.55)

No.39

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Step Response
These characteristics have been obtained by measuring on each valve.
Therefore , they may vary according to a hydraulic circuit to be used.
Flow Controls

EFBG-03

U.S.GPM L /min
300
70
250
60
200
50
40
150
30
100
20
50
10
0
0

125
100
75

0.1s

50
25
Step Signal

EFBG-06

U.S.GPM L /min
600
150
500
125

Flow Rate

L /min
150

Flow Rate

Flow Rate

U.S.GPM
40
35
30
25
20
15
10
5
0

0.1s

Step Signal

Time

100

400

75

300

50

200

25

100

EFBG-10

0.1s

Step Signal

Time

Time

Pressure Controls

EFBG-03

Pressure

3000

3000

20

EFBG-03-125-C

2000

3000

20

EFBG-06-250-C

10
Step Signal

EFBG-10
EFBG-10-500-H

20

EFBG-10-500-C
0.2s

10

Step Signal

1000

Time

MPa
30

2000

0.2s

1000

Step Signal

1000

4000

EFBG-06-250-H

2000

0.2s
10

4000

EFBG-03-125-H

PSI

MPa
30

Pressure

4000

EFBG-06
PSI

MPa
30

Pressure

PSI

Time

Flow Rate
: 125 L /min (33 U.S.GPM)
Trapped Oil Volume : < 1 L (.264 U.S.Gallons)

Time

Flow Rate
: 250 L /min (66 U.S.GPM)
Trapped Oil Volume : < 1 L (.264 U.S.Gallons)

Flow Rate
: 500 L /min (132 U.S.GPM)
Trapped Oil Volume : < 1 L (.264 U.S.Gallons)

Input Current vs. Flow

EFBG-03

EFBG-06
60

100

20

50

Flow Rate

75

15

50

40
30

200

100

150
100

400

75

300

50

200

25

100

20

10
25

0
0

10
200

400

600

800 1000

50
0
0

Input Current mA

3000

EFBG-03-125-H

3000

2000
1500

Pressure

2500
15

EFBG-03-125-C

0
0

200

400

600

800 1000

Input Current mA

No.40

0
0

20

2000

400

600

800 1000

EFBG-10
PSI
3500

EFBG-06-250-H

3000

MPa
25

20

EFBG-10-500-H

2500
15

10

1000

EFBG-06-250-C

200

Input Current mA

MPa
25

0
0

2000
1500

15

10

1000

EFBG-10-500-C

5
500

500

500

800 1000

2500

1500

10

1000

600

EFBG-06
PSI
3500

MPa
25

20

400

Input Current mA

Input Current vs. Pressure


EFBG-03
PSI
3500

200

Pressure

Flow Rate

25

Flow Rate

30

Pressure

EFBG-10
U.S.GPM L /min
500
125

U.S.GPM L /min
250
65

U.S.GPM L /min
125
32.5

200

400

600

800 1000

Input Current mA

0
0

200

400

600

800 1000

Input Current mA

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03/06

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-03-125---61/6190
EFBG-06-250---61/6190

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

35

35 34 49 21 44

33

20

29

53

22

19

26

40

27

56
15

58

18

11

57

28

59

12

32

25

53

51

14

31

24

46

45

13

37

10

51

51

30

43

52

46

25

39

50

55

45

42 41

24
47

Section X-X

46 16

2 23 36 38

List of Seals
Item

Name of Parts

36
37
38
39
40
41
42
43
44
45
46
47

O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

List of Seal Kits


Part Numbers
EFBG-03
SO-NA-A016
SO-NA-P6
SO-NB-P28
SO-NB-P32
SO-NB-P28
SO-NB-P28
SO-NB-G30
SO-NB-P28
SO-NB-P15
SO-NB-P11
SO-NB-P9
SO-NB-A016

Qty.
1
1
1
1
1
3
1
1
1
2
5
1

EFBG-06
SO-NA-P26
SO-NA-P6
SO-NB-P44
SO-NB-P42
SO-NB-P36
SO-NB-P32
SO-NB-P30
SO-NB-P28
SO-NB-P15
SO-NB-P11
SO-NB-P11
SO-NB-A016

Qty.
1
1
1
1
1
3
1
1
1
2
4
1

Model Numbers

Seal Kit Numbers

EFBG-03-125-61
EFBG-03-125-C/H-61
EFBG-06-250-61
EFBG-06-250-C/H-61

KS-EFBG-03-61
KS-EFBG-03-C-61
KS-EFBG-06-61
KS-EFBG-06-C-61

Note: When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for solenoid ass'y are included in the
seal kit.
For the detail of the solenoid ass'y seals, see the Catalogue No. Pub. EC-1302.

Solenoid Ass'y
Valve Model Numbers

33 Solenoid Ass'y Model Numbers

34 Solenoid Ass'y Model Numbers

EFBG-03-125-C/H-(E)-61/6190
E318-Y06M1-04-61
EFBG-06-250-C/H-(E)-61/6190

E318-Y06M1-28-61

EFBG-03-125-(E)-61/6190
EFBG-06-250-(E)-61/6190
Note: The connector assembly GDM-211-B-11 (Item 35) is not included in the solenoid assembly.

No.41

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-10

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-10-500---51/5190

28
25

37

33

42

40

20
21

44

40

45

36

40

18

31

12

35
Z

31

32

34

29

33

33

19

36

27

23
14
15
11
10

30
17

47 57 48 50 51 52

8 36 9 13 41 7 16 41 10 36 8

Section Z-Z

54 53 55 49 26

Section W-W
Only for Models without
Pilot Relief Valve

List of Seals

CAUTION

Qty.
Item Name of Parts
29
30
31
32
33
34
35
36
53
54
55

O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Part Numbers

Models with
Models without
Pilot Relief Valve Pilot Relief Valve

SO-NA-P34
SO-NB-G60
SO-NB-G55
SO-NB-P50
SO-NB-P48
SO-NB-P42
SO-NB-P36
SO-NB-P11
SO-NB-P14
SO-NB-A013
SO-NA-P6

1
1
3
1
5
1
1
8

1
1
3
1
5
1
1
8
1
1
1

When making replacement of seals, please do it


carefully after reading through the relevant
instructions in the Operator's Manual.

List of Seal Kits


Model Numbers

Seal Kit Numbers

EFBG-10-500-51
EFBG-10-500-C/H-51

KS-EFBG-10-51
KS-EFBG-10-C-51

Note: When ordering seals, please specify the seal kit number from the table right. In addition to the
above o-rings, o-rings for pilot valve and solenoid ass'y are included in the seal kit.
For the detail of the pilot valve and solenoid ass'y seals, see the Catalogue No. Pub. EC-1302.

Pilot Valve and Solenoid Ass'y


Valve Model Numbers

25 Pilot Valve Model Numbers

EFBG-10-500-C-(E)-51/5190

EDG-01V-C-1-PNT12-5103

EFBG-10-500-H-(E)-51/5190

EDG-01V-H-1-PNT12-5103

27 Solenoid Ass'y Model No.

E318-Y06M1-28-61

EFBG-10-500-(E)-51/5190
Note: The connector assembly GDM-211-B-11 (Item 28) is not included in the solenoid assembly.

No.42

26 Safety Valve Model No.

SB1094-2002

E Series
10 -10 Series Flow Control and Relief Valves
EFBG-03/06/10

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
Model changes have been made from 50, 51 to 61 design in the EFBG-03/06 because of changes in the pilot valve buildingin method and model changes have been made from 50 to 51-design in the EFBG-10 because of improvement in Solenoid
Ass'y.
Specification and Characteristics
No changes in specifications and characteristics between current and new design
Interchangeability in Installation
EFBG-03/06
50 51 Design 61 Design
The mounting surface are interchangeable. However, the method of building in the pilot valve has been changed, bringing
about changes in the appearance shapes and dimensions as shown below.
Current : Design 50 51
Air Vent

See EDG-01
(Catalogue No. Pub.EC-1302)
for the details of
the solenoid ass'y

Fully Extended A

Air Vent

New : Design 61

Manual Flow Adj. Screw

Manual Pressure
Adj. Screw

Front Side :
Manual Flow Adj. Screw
Rear Side :
Manual Pressure Adj. Screw

Air Vent 6 Places


See EDG-01
(Catalogue No. Pub.EC-1302)
for the details of
the solenoid ass'y

Pilot Valve
EDG-01,50 Design

Pressure Adj. Screw


for Saftey Valve

Pressure Adj. Screw


for Saftey Valve

Model Numbers

(Current) EFBG-03-125---50/5090
51/5190

217
(8.54)

93.2
(3.67)

155
(6.10)

236.5
(9.31)

EFBG-03-125---61/6190

132
(5.20)

18.7
(1.74)

248.5
(9.78)

(Current) EFBG-06-250---50/5090
51/5190

217
(8.54)

53.3
(2.10)

196
277.5
(7.72) (10.93)

EFBG-06-250---61/6190

159.5
(6,28)

(New)

(New)

289.5
(11.40)

60 Design 61Design
The mounting surface are interchangeable. There are no changes in the appearance shapes and dimensions.
EFBG-10
Mounting compatibility is provided.
Note that because of improvements made on the solenoids, the overall shapes have been changed as shown below.
Current : Design 50

New : Design 51

Manual Flow
Adj. Screw

Air Vent

Manual Flow Adj. Screw

Air Vent
3 Places
Manual Pressure
Adj. Screw

Manual Pressure
Adj. Screw

Air Vent
3 Places

Air Vent

DIMENSIONS IN
MILLIMETRES (INCHES)

No.43

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03/06 (3/8, 3/4), Sub-plate Mounting

PROPORTIONAL
CONTROLS

Specifications

Specifications
Model No.

EFBG-03
-250---51

EFBG-06
-500---51

24.5 (3550)

24.5 (3550)

L /min (U.S.GPM)

250 (66)

500 (132)

Metred Flow Adjustment Range


L /min (U.S.GPM)
Min. Pilot Pressure
MPa (PSI)
at Normal
Pilot Flow
L /min (U.S.GPM) at Transition
Rated Currnt
Coil Resistance
Differential Pressure
MPa (PSI)

2.5-250
(.66-66)

5-500
(1.32-132)

1.5 (220)
1 (.26)
4 (1.06)
850 mA
10

1.5 (220)
1 (.26)
6 (1.59)
765 mA
10

0.8 (115)

0.9 (130)

Less than 3%
Less than 1%

Less than 3%
Less than 1%

C : 1.6-15.7
(230-2275)
H : 1.8-24.5
(260-3550)

C : 1.5-15.7
(220-2275)
H : 1.5-24.5
(220-3550)

C : 850 mA
H : 870 mA

C : 820 mA
H : 880 mA

Description
Max. Operating Pressure
MPa (PSI)

Flow Controls

Max. Flow

Pressure Controls

Hysteresis
Repeatability
2

Pres. Adj. Range

MPa (PSI)

Rated Current

Coil Resistance
Hysteresis
Repeatability
Approx. Mass

10
10
Less than 3%
Less than 3%
Less than 1%
Less than 1%
Refer to page 46 to 47

kg (lbs.)

1. The specifications for pressure controls are applied to models with proportional pilot relief valve. (Ex. EFBG-03-250-C--51)
2. The maximum pressure adjustment range of the valves without proportional
pilot relief valves is 24.5 MPa (3550 PSI).

Graphic Symbols
Without Proportional Pilot Relief Valve

With Proportional Pilot Relief Valve


External Pilot

External Pilot

Internal Pilot

Internal Pilot

A
Y

X
O
M

O
M

X
O
M
V

O
M

V
T
T

No.44

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03/06

PROPORTIONAL
CONTROLS

Model Number Designation / Others


Model Number Designation

EFB

-03

-250

-C

-E

-51

Series
Number

Type of
Mounting

Valve
Size

Max. Metred Flow


L /min (U.S.GPM)

Proportional Pilot Relief


Valve Pressure Adj. Range

Pilot
Connection

Design
Number

Design
Standards

EFB :
Proportional ElectroHydraulic Flow
Control and Relief
Valve

G:
Sub-plate
Mounting

C, H :
See Specifications
None :
Without Proportional
Pilot Relief Valve

None :
Internal Pilot

51

E:
External Pilot

51

03

250 : 250 ( 66)

06

500 : 500 ( 132)

Refer to

Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Attachment
Mounting Bolts
Valve Model
Numbers
EFBG-03
EFBG-06

Socket Head Cap Screw


Japanese Std. "JIS" and European Design Std.
M12 120 Lg.
M16 120 Lg.

N. American Design Std.


1/2-13 UNC 4-3/4 Lg.
5/8-11 UNC 4-3/4 Lg.

Qty.
4
4

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see the Catalogue
No. Pub. EC-1305).
Model Numbers
EFBG-03-250(-E)-51/5190
EFBG-06-500(-E)-51/5190
EFBG-03-250-C/H(-E)-51/5190
EFBG-06-500-C/H(-E)-51/5190

Power Amplifier Model Numbers


For Flow Control

For Pres. Control

AME-D-10--20
AMN-D-10 (For DC power supply)
AME-D2-1010--10

Instructions
Drain Back Pressure
Check that the drain back pressure dose not exceed 0.2 MPa (29 PSI).
When Relief Valve Passing Flow Rate is Low in Pressure Control State
To avoid preselected pressure instability, use a passing flow rate of 15 L /min (4.0 U.S.GPM) or higher.
Further, check that the tank-line back pressure dose not exceed 0.5 MPa (70 PSI).
Safety Valve Pressure Setting
The pressure of the safety valve is preset at the value equal to the upper limit of the pressure adjustment range plus
2 MPa (290 PSI). Please adjust the pressure of the valve so preset to meet the pressure to be used actually.
To lower the pressure setting, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure
to tighten the lock nut.
Interchangeability in installation with conventional valves (10 -10 Series)
EFBG-03
There is no interchangeability in installation.
EFBG-06
A product in the high-flow series can be mounted on the conventional mounting surface but no conventional product
can be mounted on the mounting surface of the high-flow series.

No.45

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03

PROPORTIONAL
CONTROLS

Installation Drawing
EFBG-03-250-C(-E)-51/5190, EFBG-03-250 (-E)-51/5190
H

Vent Port "V"

Drain Port "Y"

13.5(.53) Dia. Through


21(.83) Dia. Spotface
4 Places
Outlet Port "A"

Tank Port "T"

11.7
(.46)

14.2
(.56)

26.2
(1.03)

153
(6.02)
101.6
(4.00)
26.8
(1.06)

V
T
Y

103.3
(4.07)
139.5
(5.49)

130
(5.12)
101.6
(4.00)
45.8
(1.80)

P
Inlet Port "P"
Pilot Pressure Port "X"
11.7
(.46)
Manual Flow Adj.Screw
3(.12) Hex. Soc.

Cable Departure (For Flow Control)


Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

85.8
(3.38)
125
(4.92)

Manual Pressure Adj.Screw


3(.12) Hex. Soc.

Air Vent
3(.12) Hex. Soc.
3 Places

Pressure Adj. Srerw


for Safety Valve
3(.12) Hex Soc.
INC.

View Arrow Z

INC.

Air Vent
3(.12) Hex. Soc.
3 Places

Cable Departure (For Pressure Control)


Cable Applicable:
Outside Dia. . . . . . . 8-10 mm (.31 - .39 in.)
Conductor Area . . . Not Exceeding 1.5 mm2 (.002 sq. in.)
Models with proportional pilot
relief valve (EFBG-03-250-C/H)
only.

255.2
(10.05)
293.5
(11.56)

274.5
(10.81)
236.2
(9.30)

Lock Nut
10(.39) Hex.

100
(3.94)
99
(3.90)

Approx. Mass ...... 19 kg (41.9 lbs.)

6
(.24)

DIMENSIONS IN
MILLIMETRES (INCHES)

101.6(4.00)

130
(5.12)

X
A

EFBG-03-250---5190 1/2-13 UNC

V
11.7
(.46)

No.46

M12

95.3(3.75)

14.2
(.56)

EFBG-03-250---51

"B" Thd.

7(.28) Dia. 7(.28) Deep 2 Places


(For Locating Pin)

101.6(4.00)

0.8
(.03)

Prepare a mounting surface as shown to the right.


Also finish it finely.

6.2(.24) Dia. (Max.)


3 Places ("V", "X" & "Y" Port)

24.8
(.98)

45
(1.77)
59(2.32)

Dimensions of valve mounting surface

Model Numbers

26(1.02) Dia. (Max.)


3 Places ("P", "A" & "T" Port)

76.8(3.02)
50.8(2.00)

87.9(3.46)

12.7
(.50)
28.6
(1.13)

Two Locating Pins


6(.24) Dia.

102.4(4.03)
Mounting Surface
(O-Rings Furnished)

"B" Thd 24(.94) Deep 4 Places


125
(4.92)

E Series
High Flow Series Flow Control and Relief Valves
EFBG-06

PROPORTIONAL
CONTROLS

Installation Drawing
Models with Proportional Pilot Relief Valve
EFBG-06-500-C(-E)-51/5190
H
Pressure Adj. Screw
for Safety Valve
3(.12) Hex. Soc.
INC.

180
(7.09)
146.1
(5.75)

Inlet Port "P"

Pilot Pressure Port "X"


(Rear Side)
Air Vent 3(.12) Hex. Soc.
3 Places

151.3
(5.96)
215.8
(8.50)

180
(7.09)
133.4
(5.25)
112
(4.41)

26.3
(1.04)

Manual Flow Adj.Screw


3(.12) Hex. Soc.
INC.
17.5(.69) Dia. Through
26(1.02) Dia. Spotface
17
4 Places
(.67)

Models without Proportional Pilot


Relief Valve
EFBG-06-500(-E)-51/5190

Pressure Adj. Screw


for Safety Valve
3(.12) Hex. Soc.

INC.

Lock Nut
10(.39) Hex.

33
(1.30)
111
(4.37)

Tank Port "T"


Drain Port "Y"

Outlet Port "A"


Vent Port "V"

Cable Departure (For Pressure Control)


Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

Cable Departure (For Flow Control)


Cable Applicable:
Outside Dia. . . . 8-10 mm
(.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

For other dimensions, please refer to the models


with Proportional Pilot Relief Valve.

Air Vent 3(.12) Hex. Soc.


3 Places
Manual Pressure Adj.Screw
3(.12) Hex. Soc.
INC.

Sling Fitting
2 Places

8
(.31)

96
(3.78)
95
(3.74)

288.5
(11.36)

311.5
(12.26)
273.2
(10.76)

Approx. Mass ...... 33 kg (72.8 lbs.)

Mounting Surface
(O-Rings Furnished)

Two Locating Pins


16(.63) Dia.

Approx. Mass ...... 35 kg (77.2 lbs.)

DIMENSIONS IN
MILLIMETRES (INCHES)

146.1
(5.75)
144.5
(5.69)
115
(4.53)
73.1
(2.88)

Prepare a mounting surface as shown to the right.


Also finish it finely.

35(1.38) Dia. (Max.)


3 Places ("P", "A" & "T" Port)
"B" Thd. "C" Deep
4 Places

Model Numbers
EFBG-06-500---51

"B" Thd.

M16

30 (1.18)

EFBG-06-500---5190 5/8-11 UNC

35 (1.38)

180
(7.09)
26.3
(1.04)

7.5
(.30)
41.3
(1.63)

31
(1.22)
1.6
(.06)
P
X Y
T
A
7(.28) Dia. (Max.)
17
(.67)

85.7
(3.37)
110
(4.33)
133.4
(5.25)

Dimensions of valve mounting surface

1.9
(.07)
180
(7.09)

17(.67) Dia. 10(.39) Deep


2 Places
(For Locating Pin)
14(.55) Dia. (Max.)

No.47

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03/06

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Step Response
These characteristics have been obtained by measuring on each valve.
Therefore , they may vary according to a hydraulic circuit to be used.
Flow Controls

40

EFBG-03-250

150
100

0.25s

20
50
0

80

300
200

0.25s

40
100
0

Step Signal

EFBG-06-500

U.S.GPM L /min
500
120
400

Flow Rate

Flow Rate

U.S.GPM L /min
250
60
200

Step Signal

Time

Time

Pressure Controls
MPa
PSI
EFBG-03-250-H

MPa
28

PSI
4000

28

4000

24

24
3000

20

Pressure

Pressure

3000

16

2000

12

0.2s

1000

20
16

2000

12
8

1000

0.25s

4
0

EFBG-06-500-H

Step Signal

Step Signal

Time

Time

Input Current vs. Flow


EFBG-03-250

U.S.GPM L /min
250

120

60

40

200

150

30
100

80

300

60
200
40

20
10

400

100

Flow Rate

Flow Rate

50

EFBG-06-500

U.S.GPM L /min
500

50
0
0

100

20

200

400

600

800

0
0

900

200

400

800

600

1000

Input Current mA

Input Current mA

Input Current vs. Pressure


PSI
3500
3000

EFBG-03-250

MPa
25

PSI
3500
3000

20

EFBG-06-500

MPa
25

20
EFBG-06-500-H

2000

15

Pressure

Pressure

EFBG-03-250-H
2000

10

10

1000

EFBG-03-250-C

1000

0
0

200

400

600

Input Current mA

No.48

EFBG-06-500-C
5

15

800

900

0
0

200

400

600

Input Current mA

800

900

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-03-250---51/5190

57

32

28

30

46

Y
X

Detail of Safety Valve


(Item 31)

29

31

43 52

32

42 60 61 59 62 64 63

15

47

48

26

14

27

13

25

16

37

24

56

23

44 40 45 58

Section X-X
17
21

42

39

51

34

36

33

20

12

54

19

50

22

51

49

18

41

11

42 10 38

35

40 55

Section Y-Y
53

Section W-W

List of Seals
Item
33
34
35
36
37
38
39
40
41
42
43
44
45

Name of Parts
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Section Z-Z
Part Numbers
SO-NB-P42
SO-NB-P32
SO-NB-P30
SO-NB-P28
SO-NB-P22
SO-NB-P21
SO-NB-P20
SO-NB-P14
SO-NB-P11
SO-NB-P9
SO-NB-G30
SO-NB-A013
SO-NA-P6

Qty.
1
1
1
1
1
1
1
2
2
6
3
1
1

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

List of Seal Kits


Model Numbers

Seal Kit Numbers

EFBG-03-250-51
EFBG-03-250-C/H-51

KS-EFBG-03-250-51
KS-EFBG-03-250-C-51

O-rings, ref. Nos. 37 and 39, are used only with the proportional pilot relief
valve (EFBG-03-250-C/H).
Note: When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for solenoid ass'y are included in the
seal kit.
For the detail of the solenoid ass'y seals, see the Catalogue No. Pub. EC-1302.

Solenoid Ass'y and Safety Valve


Valve Model Numbers
EFBG-03-250-C/H(-E)-51/5190
EFBG-03-250(-E)-51/5190

29 Solenoid Ass'y Model No.

E318-Y06M1-04-61

30 Solenoid Ass'y Model No.

31 Safety Valve Model No.

E318-Y06M1-28-61

SB1094-2002

Note: The connector assembly GDM-211-B-11 (Item 32) is not included in the solenoid assembly.

No.49

E Series
High Flow Series Flow Control and Relief Valves
EFBG-06

PROPORTIONAL
CONTROLS

Spare Parts List


EFBG-06-500---51/5190

Detail of Safety Valve (Item 24)


Models Without Pilot Relief
Valve : EFBG-06-500(-E)

21
48

22

38

24

35

23
25

55 56 54 51 53 52

28

32
Q
W

50 37 31 36
Section S-S

39
16

17

40

42

19

44

11

20

29

33

34

26

46

33

10

42

14

18

27

12

49
13 35 2 30

47

32

33 43

Section U-U

Section Q-Q

28 1 15 6

List of Seals
Item
26
27
28
29
30
31
32
33
34
35
36
37

Name of Parts
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring

Part Numbers
SO-NB-P46
SO-NB-P42
SO-NB-P40
SO-NB-P36
SO-NB-P34
SO-NB-P14
SO-NB-P11
SO-NB-P9
SO-NB-G55
SO-NB-G30
SO-NB-AO13
SO-NA-P6

Qty.
1
1
3
1
1
1
4
4
1
2
1
1

O-rings, ref. Nos. 31, 36 and 37, are used only with the proportional pilot relief
valve [EFBG-06-500(-E)].
Note: When ordering seals, please specify the seal kit number from the table right.
In addition to the above o-rings, o-rings for pilot valve and solenoid ass'y are
included in the seal kit. For the detail of the pilot valve and solenoid ass'y seals,
see the Catalogue No. Pub. EC-1302.

40
41 40

Section Z-Z

Section W-W

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

List of Seal Kits


Model Numbers
EFBG-06-500-51
EFBG-06-500-C/H-51

Seal Kit Numbers


KS-EFBG-06-500-51
KS-EFBG-06-500-C-51

Pilot Valve and Solenoid Ass'y


Valve Model Numbers

22 Pilot Valve Model Numbers

EFBG-06-500-C(-E)-51/5190

EDG-01V-C-1-PNT11-5103

EFBG-06-500-H(-E)-51/5190

EDG-01V-H-1-PNT11-5103

23 Solenoid Ass'y Model No.

E318-Y06M1-28-61

EFBG-06-500(-E)-51/5190
Note: The connector assembly GDM-211-B-11 (Item 25) is not included in the solenoid assembly.

No.50

24 Safety Valve Model No.

SB1094-2002

E Series
High Flow Series Flow Control and Relief Valves
EFBG-03/06

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Interchangeability between Current and New Design
EFBG-03/06 series valves have changed model from 50 to 51 design in line with the model change of solenoid ass'y.
Specifications and Characteristics
No changes in specifications and characteristics between current and new design.
Mounting Interchangeability
There is an interchangeability in the mounting dimensions between current and new design, however, note that
because of improvements made on the solenoids, the overall shapes have been changed as shown below.

EFBG-03
Current : Design 50

New : Design 51

Manual Pressure Adj. Screw


Manual Flow Adj. Screw

Manual Pressure Adj. Screw


Manual Flow Adj. Screw

Air Vent
Air Vent

Air Vent
3 Places

Air Vent
3 Places

EFBG-06
Current : Design 50
Manual Flow Adj. Screw

Pressure Adj. Screw


for Safety Valve

New : Design 51
Manual Flow Adj. Screw

Pressure Adj. Screw


for Safety Valve

Air Vent
3 Places

Air Vent
Air Vent

Air Vent
3 Places
Manual Pressure Adj. Screw

Manual Pressure
Adj. Screw

No.51

Pub. EC-1304

E SERIES
PROPORTIONAL DIRECTIONAL AND
FLOW CONTROL VALVES
EDFHG-03/04/06 (3/8,1/2,3/4) Sub-plate Mounting

PROPORTIONAL
CONTROLS

General Information
Up to 24.5 MPa (3550 PSI), 280 L/min (74.0 U.S.GPM)
These valves are double-deck directional and flow control valves
employing as their pilot the electro-hydraulic proportional pressure
reducing valves with two proportional solenoids. The flow rate can be
controlled by changing an input current to the solenoids and the direction
of the flow can be controlled by providing the current to either solenoid
of the two.
By combining the valves with the power amplifiers specially designed
for the valves, the speed control, acceleration, deceleration and directional control can be done with a single valve, which eventually makes
the hydraulic circuits simple and contributes the cost of the hydraulic
systems.
a

b
Y X

Hydraulic Fluids
Fluid Types
Any type of hydraulic fluid listed in the table below can be used.
Petroleum base oils
Synthetic Fluids
Water Containing Fluids

Use fluids equivalent to ISO VG 32 or VG 46.


Use phosphate ester or polyol ester fluid. When phosphate ester fluid is used, prefix "F-" to the
model number because the special seals (fluororubber) are required to be used.
Use water-glycol fluid.

Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

Recommended Fluid Viscosity and Temperature


Use hydraulic fluids which satisfy the both recommended viscosity and oil temperatures given in the table below.
Viscosity

Temperature

20 - 400 mm2/s
(98 - 1800 SSU)

0 - +60C
(32 - 140F)

Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise
lead to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638Grade 11. Use 20 m or finer line filter.

No.1

E Series
Directional and Flow Control Valves
EDFHG-03/04/06

PROPORTIONAL
CONTROLS

Specifications / Model Number Designation


Specifications
Model No.
Description

EDFHG-03

EDFHG-04

Max. Operating Pressure

24.5 (3550)

MPa (PSI)
Rated Flow
L /min (U.S.GPM)
at Valve Pressure Difference:
1.0 MPa (145 PSI)
Pilot Pressure 1
MPa (PSI)
at Normal
Pilot Flow
L /min (U.S.GPM) at Transition
Max. Tank Line Back Pressure
MPa (PSI)
Max. Drain Line Back Pressure
MPa (PSI)
Rated Current
Coil Resistance
Hysteresis
Repeatability
Approx. Mass
kg (lbs.)

EDFHG-06

100 (26.4)

140 (37.0)

1 (.26)
3 (.79)

1.5 - 16 (220 - 2320)


1 (.26)
4 (1.06)

16 (2320)

21 (3050)
3.0 (435)

800 mA

280 (74.0)

1 (.26)
6 (1.59)
21 (3050)

980 mA
10
Less than 5%
Less than 1%

11 (24.3)

900 mA
3
3

12 (26.5)

15 (33.1)

1. Take care to keep the difference between the pilot pressure and drain port back pressure
consistently greater than 1.5 MPa (220 PSI).
2. To obtain stable performance, keep the drain port back pressure low and minimize its fluctuations.
3. The hysteresis and repeatability values indicated in the specifications for each control valve are
determined under the following conditions:
Hysteresis Value: Obtained when Yuken's applicable power amplifier is used.
Repeatability Value: Obtained when Yuken's applicable power amplifier is used under the
same conditions.

Model Number Designation

F-

EDFHG -03

-100

-XY

-E

-31

Direction
of Flow

Pilot
Connection

Design
Number

Design
Standards

-3C2

Special
Seals

Series
Number

Valve
Size

Rated Flow
L /min (U.S.GPM)

F:
Special
Seals for
Phosphate
Ester Type
Fluids
(Omit if not
required)

EDFHG:
Proportional
ElectroHydraulic
Directional &
Flow Control
Valves
(Sub-Plate
Mtg.)

03

100 : 100 (26.4)

04

140 : 140 (37.0)

06

280 : 280 (74.0)

Spool Type

31
3C2

3C40

E:
External Pilot

XY : Metre-in
Metre-out

None :
Internal Pilot

31

1. Spool type shown in the column is for the centre position.


2. Design Standards: None ........... Japanese Standard "JIS" and European Design Standard
90 ............... N. American Design Standard

Graphic Symbols
External Pilot Type
a

No.2

31

b
Y X

Internal Pilot Type


a

b
Y

Refer to

E Series
Directional and Flow Control Valves
EDFHG-03/04/06

PROPORTIONAL
CONTROLS

Sub-plate / Instructions / Others


Attachment
Mounting Bolts
Model
Numbers
EDFHG-03
EDFHG-04
EDFHG-06

Socket Head Cap Screw


Japanese Standard "JIS"
European Design Standard
M6 35 Lg.
M6 45 Lg.
M10 50 Lg.
M12 60 Lg.

N. American Design Standard

Qty.

1/4-20 UNC 1-1/2 Lg.


1/4-20 UNC 1-3/4 Lg.
3/8-16 UNC 2 Lg.
1/2-13 UNC 2-1/2 Lg.

4
2
4
6

Tightening Torque
Nm (in. lbs.)
12 - 15 (106 - 133)
12 - 15 (106 - 133)
58 - 72 (513 - 637)
100 - 123 (885 - 1089)

Sub-Plates
Valve
Model
Numbers
EDFHG-03
EDFHG-04
EDFHG-06

Japanese Standard "JIS"


Approx.
Sub-plate
Thread
Mass
Model Numbers
Size
kg (lbs.)

European Design Standard


Sub-plate
Model Numbers

Thread
Size

Approx.
Mass
kg (lbs.)

N. American Design Standard


Approx.
Sub-plate
Thread
Mass
Model Numbers
Size
kg (lbs.)

DHGM-03Y-10

Rc 3/4

4.7 (10.4)

DHGM-03Y-1080

3/4 BSP.F

4.7 (10.4)

DHGM-03Y-1090

3/4 NPT

4.7 (10.4)

DHGM-04-20

Rc 1/2

4.4 (9.7)

DHGM-04-2080

1/2 BSP.F

4.4 (9.7)

DHGM-04-2090

1/2 NPT

4.4 (9.7)

DHGM-04X-20

Rc 3/4

4.1 (9.0)

DHGM-04X-2080

3/4 BSP.F

4.1 (9.0)

DHGM-04X-2090

3/4 NPT

4.1 (9.0)

DHGM-06-50

Rc 3/4

7.4 (16.3)

DHGM-06-5080

3/4 BSP.F

8.5 (18.7)

DHGM-06-5090

3/4 NPT

7.4 (16.3)

Rc 1

7.4 (16.3)

DHGM-06X-5080

1 BSP.F

8.5 (18.7)

DHGM-06X-5090

1 NPT

7.4 (16.3)

DHGM-06X-50

Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.

Applicable Power Amplifiers


For stable performance, it is recommended that Yuken's applicable power amplifiers be used (for details see
the Catalogue No. Pub. EC-1305).
Model Numbers: SK1091-D24-10

Instructions
Mounting Position
Be sure to mount the Directional and Flow Control
Valve so that the air vents come upside.
[Bad example]

[Good example]
Air Vent

SOL b

SOL a

SOL a

Air Vent

Air Vent

SOL b

Air Bleeding
To ensure stable control, bleed the air form solenoid
completely and fill its icon core with oil. For this purpose,
it is recommended to provide the drain line with a check
valve having a cracking pressure of about 0.04 MPa (5.8
PSI).
Bleeding can be done by slowly loosening an air vent.
There are three air vents. Chose one that appears most
helpful (see the figure below).
In addition, be sure to extend the end of the drain line into
the oil.

Air Vent
Solenoid

Manual Adjustment
In the event of an electric fault or emergency, a manual
shift can be made by screwing in the manual adjustment screw. Take care, however, that this manual shift
has no flows adjusting function.
For this operation, set the pilot pressure (or P-port
pressure on an internal-pilot model) below 7 MPa (1020
PSI).
After operation, be sure to return the manual adjustment screw completely to the original position (see the
figure right).

Air Vent
3 Places

Manual Adj. Screw

10 Series Solenoid

No.3

E Series
Directional and Flow Control Valves
EDFHG-03/04

PROPORTIONAL
CONTROLS

Installation Drawing
EDFHG-03-100-3C-XY--31/3190

Mounting Surface:

Main port ... Conform to ISO 4401-AC-05-4-A.


Pilot/drain ports ... Conform to ISO.
Cylinder Port "B"

Pressure Port "P"


Cylinder Port "A"

Pilot Drain Port "Y"

Pilot Pressure Port "X"


285.8
(11.25)
114.9
(4.52)

46
(1.81)
70
(2.76)

54
(2.13)

12
(.47)

Connector
The direction can be altered
to every 90 degree angles.

Connector
The direction can be altered
to every 90 degree angles.

7(.28) Dia. Through


11(.43) Dia. Spotface
4 Places

Tank Port "T"

37.6 39
(1.48) (1.54)

93.6
(3.68)

Air Vent
3(.12) Hex. Soc.
3 Places
(Both Ends)

SOL a

SOL b

26(1.02)

Manual
Adjustment
Screw
3(.12) Hex.Soc.
(Both Ends)
Mounting Surface
(O-Rings Furnished)

DIMENSIONS IN
MILLIMETRES (INCHES)

79
(3.11)

212
(8.35)

Mounting surface: Conform to ISO4401-AD-07-4-A.


Pressure Port "P"
285.8
(11.25)
101.6
(4.00)
34(1.34)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

91.3
(3.59)

Connector

Air Vent
3(.12) Hex. Soc.
3 Places
(Both Ends)

3(.12) Dia. Two Locating Pins

No.4

4
(.16)

34
(1.34)
35
(1.38)
116
(4.57)
185.5
(7.30)

57.5
(2.26)

27.5
(1.08)

48
(1.89)

Cylinder Port "A"


50
Cable Departure
(1.97)
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.) 7(.28) Dia. Through
11(.43) Dia. Spotface
Conductor Area
2 Places
. . . Not Exceeding 1.5 mm2
65.6
(.002 sq. in.)
(2.58)

1.5
(.06)

69.8
(2.75)

Position of cable departure can


be changed. For details, refer to
above EDFHG-03.

Pilot Pressure Port "X"

Pilot Drain Port "Y"


Cylinder Port "B"
65.6
(2.58)

SOL a

39
(1.54)

SOL b

Manual
Adjustment
Screw
3(.12) Hex.Soc.
(Both Ends)
Mounting Surface
(O-Rings Furnished)
204
(8.03)

50.4
(1.98)

91
(3.58)

Tank Port "T"

72.9
(2.87)

EDFHG-04-140-3C-XY--31/3190

9.1
(.36)

110
57.5
(4.33)
(2.26)
179.5
(7.07)

27.5
(1.08)

48
(1.89)

Cable Departure
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
. . . Not Exceeding 1.5 mm2
(.002 sq. in.)

27(1.06)

Of the two tank ports "T", the tank


port in the left side is normally used
in our standard sub-plate, though,
either side of the tank port "T" can be
used without problem.

E Series
Directional and Flow Control Valves
EDFHG-06

PROPORTIONAL
CONTROLS

Installation Drawing / Others


EDFHG-06-280-3C-XY--31/3190

Mounting surface: Conform to ISO4401-AE-08-4-A.


Pressure Port "P"
Pilot Drain Port "Y"
285.8
(11.25)
130.2
(5.13)

65.4
(2.57)
53.2
(2.09)

Pilot Pressure Port "X"


Connector
48
(1.89)

77
(3.03)

Cylinder Port "A"


Cable Departure
Cylinder Port "B"
Cable Applicable:
Outside Dia. . . . 8-10 mm (.31 - .39 in.)
Conductor Area
39
65.6
65.6
. . . Not Exceeding 1.5 mm2
(2.58)
(1.54) (2.58)
(.002 sq. in.)
Air Vent
3(.12) Hex. Soc.
3 Places
(Both Ends)

6(.24) Dia. Two Locating Pins

206.5
(8.13)

SOL a

13.5(.53) Dia. Through


20(.79) Dia. Spotface
6 Places

SOL b

Manual
Adjustment
Screw
3(.12) Hex.Soc.
(Both Ends)

6
(.24)

137
(5.39)

41
(1.61)

57.5
(2.26)

27.5
(1.08)

13
(.51)

92.1
(3.63)

Tank Port "T"

118
(4.65)

Position of cable departure can be changed. For


details, refer to EDFHG-03 valve on page 4.

50.3
(1.98)

Mounting Surface
(O-Rings Furnished)
255
(10.04)

DIMENSIONS IN
MILLIMETRES (INCHES)

Interchangeability between Current and New Design


Specifications and Characteristics
No changes in specifications and characteristics between current and new design.
Mounting Interchangeability
The mounting surface are interchangeable.
Note that because of improvements made on the solenoids, the overall shapes and dimensions have been changed as
shown below.

Current: Design 30

New: Design 31
Air Vent
Manual
Adjustment
Screw

Manual
Adjustment
Screw
SOL a

SOL b

Air Vent
3 Places

No.5

E Series
Sub-Plate for
Directional and Flow Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-Plates

DHGM-03Y-10/1080/1090
Sub-plate
Model Numbers
DHGM-03Y-10

120
(4.72)
15
(.59)
18
(.71)

"C" Thd.

DHGM-03Y-1090

F
mm (in.)

M6

13(.51)

1/4-20 UNC

15(.59)

Rc 1/4

Rc 3/4

1/4 BSP.F

DHGM-03Y-1080 3/4 BSP.F

90
(3.54)

"E" Thd.

"D" Thd.

1/4 NPT

3/4 NPT

62
(2.44)
54
(2.13)

37.3(1.47)

43(1.69)

10
(.39)

47
(1.85)

19
(.75)

11
(.43)

70
(2.76)

76
(2.99)

25(.98)

3.2
(.13)
12
(.47)

6.4(.25)

21.5(.85)

32.5(1.28)

80
(3.15)
45
(1.77)

42(1.65)

16.7(.66)

46
(1.81)

90
(3.54)

110
(4.33)

19
(.75)

27(1.06)

8(.31)

10
(.39)
22(.87)

25
(.98)

50
(1.97)

11(.43) Dia.
4 Places

16(.63)

"D" Thd.
Used only on external
pilot type valves.
To be plugged on internal
pilot type valves.

A
6.2(.24) Dia.

"C" Thd.
4 Places

6.2(.24) Dia.

19
(.75)

"D" Thd.

92
(3.62)

"E" Thd. "F" Deep


4 Places

DIMENSIONS IN
MILLIMETRES (INCHES)

04
DHGM- 04X -20/2080/2090
Sub-plate
Model Numbers

20
(.79)

10.1
(.40)

19
(.75)

90
(3.54)

P X
B
Y

57.1
(2.25)

16
(.63)

1.6(.06)

14.2
(.56)

55.6
(2.19)

69.8
(2.75)

13.1
(.52)
71.4
(2.81)

12
(.47)
96
(3.78)

18.3(.72)

125
(4.92)
Refer to

"C" Thd.
4 Places

90
(3.54)
46
(1.81)

X
Y

76
(2.99)

"E" Thd.
17(.67) Deep
4 Places

34(1.34)

120
(4.72)

36
(1.42)

33(1.30)

76.7
(3.02)
50
(1.97)

"F" Thd.

21.5(.85)

101.6
(4.00)

"E" Thd.

29
(1.14)

32.2(1.27)

65
(2.56)

166
(6.54)

"D" Thd.

DHGM-04-20
Rc 1/2
Rc 1/4
Rc 3/4
DHGM-04X-20
M10
M6
DHGM-04-2080 1/2 BSP.F
1/4 BSP.F
DHGM-04X-2080 3/4 BSP.F
DHGM-04-2090
1/2 NPT
1/4 NPT 3/8-16 UNC 1/4-20 UNC
DHGM-04X-2090 3/4 NPT

190
(7.48)
12(.47)

"C" Thd.

A
11(.43) Dia. Through
17.5(.69) Dia. Spotface
4 Places
3.6(.14) Dia.
5(.20) Deep
2 Places

65.8
(2.59)
14.2
(.56)

88.1
(3.47)
130
(5.12)

6(.24) Dia. 2 Places


17.5(.69) Dia.
4 Places
"F" Thd. 12(.47) Deep
2 Places

"D" Thd.
2 Places

58
(2.28)
102
(4.02)
137.5
(5.41)

Used only on external pilot type valves. To be plugged on internal pilot


type valves.

No.6

E Series
Sub-Plate for
Directional and Flow Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
Sub-Plates

06
DHGM- 06X -50/5090
204
(8.03)
12
(.47)

180
(7.09)

25
(.98)

130.2
(5.13)

Sub-plate
Model Numbers

"C" Thd.

DHGM-06-50
DHGM-06X-50
DHGM-06-5090
DHGM-06X-5090

Rc 3/4
Rc 1
3/4 NPT
1 NPT

"D" Thd.

"E" Thd.

F
mm (in.)

Rc 1/4

M12

24 (.94)

1/4 NPT

1/2-13 UNC

26 (1.02)

112.7
(4.44)
11(.43) Dia.
"D" Thd. (From Rear)
4 Places

94.5
(3.72)
77
(3.03)

"E" Thd. "F" Deep


6 Places

53.2
(2.09)
29.4(1.16)

17.5(.69)

19.1(.75)

Y
B

17.5
(.69)

100.8
(3.97)

7(.28) Dia.
8(.31) Deep
2 Places

12.5
(.49)

34(1.34)

11(.43) Dia. Through


17.5(.69) Dia. Spotface
4 Places

29.5
(1.16)

Used only on external


pilot type valves.
To be plugged on internal
pilot type valves.

73.1
(2.88)

46.1
(1.81)

TP

96.9
(3.81)

Not used
(plug is not required)

5.6(.22)

74.6
(2.94)

92.1
(3.63)
12
(.47)

116
(4.57)

Not used
(plug is not required)

35(1.38)
50
(1.97)

23(.91) Dia.
"C" Thd. (From Rear)
4 Places

126.2
(4.97)
156
(6.14)

DIMENSIONS IN
MILLIMETRES (INCHES)

06
DHGM- 06X -5080
D
E

12.5
(.49)
156
(6.14)

11(.43) Dia.
4 Places

DHGM-06-5080
DHGM-06X-5080

"C" Thd.

D
E
3/4 BSP.F 151.2 (5.95) 137.7 (5.42)
1 BSP.F

155.2 (6.11)

148 (5.83)

Y
B

N
L

"C" Thd.
4 Places

24.5(.96) Dia.
4 Places

Sub-plate
Model Numbers

F
102 (4.02)

Dimensions
H
54.4 (2.14)

106 (4.17)

50 (1.97)

mm (Inches)
J
K
30.6 (1.20) 125.8 (4.95)
25

55
(2.17)
83.5
(3.29)

A B

Not used
(plug is not
required)

28
(1.10)

PY

H
Not used
(plug is not
required)

116
(4.57)

26.4
(1.04)

8.9
(.35)

12
(.47)

50
(1.97)
35
(1.38)

130.2
(5.13)

11.9
(.47)

25
(.98)

1/4 BSP.F Thd.


4 Places

82
(3.23)

12
(.47)

134
(5.28)
110
(4.33)
92.1
(3.63)

M12 Thd.
24(.94) Deep
6 Places

204
(8.03)
180
(7.09)

(.98)

130 (5.12)

Used only on external


pilot type valves.
To be plugged on internal
pilot type valves.

L
78.2 (3.08)

N
42.5 (1.67)

74 (2.91)

32 (1.26)

For other dimensions, refer to "DHGM-06-50/5090" above.

No.7

E Series
Directional and Flow Control Valves
EDFHG-03/04/06

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Input Current vs. Flow

Valve Pressure Difference vs. Flow

Viscosity : 30 mm2/s (141 SSU)


Valve Pres. Difference : P A (B), B (A) T 1 MPa (145 PSI)

Viscosity : 30 mm2/s (141 SSU)

EDFHG-03

3500 PSI
1000 2000 3000
U.S.GPM
35 A B

0
140
U.S.GPM

120

30
A B

80

P T

P T

25
20

60

15

40

10

20

1000 800 600 400 200 0 200 400 600 800 1000
Input Current mA

Flow Rate

A B

Flow Rate

100

750 mA

80

10
600 mA

AB

10

24
24.5
40 Valve Pres. Diff. MPa

20

80

600 mA

700 mA

30

120

750 mA

P T 35

P T

20

40

Valve Pres. Diff.


MPa
24.5
24
16
8

30
700 mA

140

U.S.GPM
3000 2000 1000
PSI 3500

16

Flow Rate

L /min

L /min 120
Flow Rate

EDFHG-03

L /min

EDFHG-04

3500 PSI
1000 2000 3000
U.S.GPM

0
280
L /min

U.S.GPM

160

40

140
AB

P T

P T

80

20

60
40

80

20

24.5
24

700 mA

24
24.5
Valve Pres. Diff. MPa
80

40
1000 800 600 400 200 0 200 400 600 800 1000
Input Current mA

160

0
AB

20

20
0

40

700 mA

10

800 mA
900 mA

60

AB

60 P T

800 mA

160

Valve Pres. Diff.


MPa
16
8

30

100

Flow Rate

Flow Rate

120

AB

900 mA

240

P T 70

280

U.S.GPM
3000 2000 1000
PSI 3500

16

Flow Rate

L /min

70

240
Flow Rate

EDFHG-04

L /min

EDFHG-06

3500 PSI
1000 2000 3000
U.S.GPM
100 A B
900 mA

EDFHG-06

300

400
L /min

U.S.GPM
80
70

250
AB

60

P T

P T

50

30

Valve Pres. Diff.


MPa
24.5
24
16
8

50

1000 800 600 400 200 0 200 400 600 800 1000
Input Current mA

20

20

10

40

60
AB
P T

100

700 mA
0

700 mA

100
200

24
24.5
Valve Pres. Diff. MPa

300

80
800 mA
100

L /min

900 mA

400

U.S.GPM
3000 2000 1000
PSI 3500

20

600 mA

600 mA

100

No.8

60

200

Flow Rate

40

150

80 P T

40
Flow Rate

Flow Rate

200

AB

800 mA
300

Flow Rate

L /min

16

E Series
Directional and Flow Control Valves
EDFHG-03/04/06

PROPORTIONAL
CONTROLS

Typical Performance Characteristics


Frequency Response

Step Response
These characteristics have been obtained by measuring
on each valve. Therefore, they may vary according to a
hydraulic circuit to be used.

0
-10
-20
-30

Frequency (Hz)
0.2 0.4 0.7 1
2
4

7 10

20

40
Viscosity : 30 mm2/s(141 SSU)
Supply Pressure : 15.7 MPa(2275 PSI)

Gain
Phase

U.S.GPM L/min
140
35
120
30

Flow Rate

0
- 20
- 40
- 60
- 80
-100
-120
-140
-160
-180

Gain (dB)

Phase (deg.)

EDFHG-03

Model Number : EDFHG-03-100-3C2-E-31


Viscosity : 30 mm2/s(141 SSU)
Pilot Pressure : 15.7 MPa(2275 PSI)
Travel of Spool : 10% of Maximum Stroke

EDFHG-03

100
20

80

0.1 s

60
10

40

Step Signal

0
-10
-20
-30

Frequency (Hz)
0.2 0.4 0.7 1
2
4

7 10

20

Time

40
U.S.GPM L/min

Gain

45

175

40

150

Phase

Flow Rate

0
- 20
- 40
- 60
- 80
-100
-120
-140
-160
-180

Gain (dB)

Phase (deg.)

EDFHG-04

Model Number : EDFHG-04-140-3C2-E-31


Viscosity : 30 mm2/s(141 SSU)
Pilot Pressure : 15.7 MPa(2275 PSI)
Travel of Spool : 10% of Maximum Stroke

125
30
100
20

50

Frequency (Hz)
0.2 0.4 0.7 1
2
4

Time
7 10

Gain

Phase

Model Number : EDFHG-06-280-3C2-E-31


Viscosity : 30 mm2/s(141 SSU)
Pilot Pressure : 15.7 MPa(2275 PSI)
Travel of Spool : 10% of Maximum Stroke

Step Signal

10

20

40

U.S.GPM L/min
400
100
350

Flow Rate

Gain (dB)

Phase (deg.)

0
-10
-20
-30

0.1 s

75

EDFHG-06
0
- 20
- 40
- 60
- 80
-100
-120
-140
-160
-180

EDFHG-04

80

EDFHG-06

300
250

60
200
40

0.1 s

150
100

Step Signal

20

Time

No.9

E Series
Directional and Flow Control Valves
EDFHG-03/04/06

PROPORTIONAL
CONTROLS

Spare Parts List


EDFHG-03-100-3C-XY--31/3190
EDFHG-04-140-3C-XY--31/3190
EDFHG-06-280-3C-XY--31/3190

15

16

Removed for
internal pilot models

8 17 14 6 21 26 18 20 25 7 19 24 29 22
23
28
27

Section X-X

X
B

16

10

11

12

15

13

Section Y-Y
List of Seals & Solenoid Ass'y
Item
6
11
12
13
14
25
26

Name of Parts

EDFHG-03

EDFHG-04

EDFHG-06

Part Numbers

Part Numbers
Part Numbers
Qty.
Qty.
Qty.
Solenoid Ass'y E318-Y06M1-28-61 2 E318-Y06M1-28-61 2 E318-Y06M1-28-61 2
O-Ring
2
2
2
SO-NB-P34
SO-NB-P40
SO-NB-P28
O-Ring
4
4
5
SO-NB-P30
SO-NB-P22
SO-NB-A014
O-Ring
SO-NB-P14
2
SO-NB-P9
2
SO-NB-P9
2
O-Ring
SO-NB-P9
SO-NB-P10
SO-NB-P9
2
2
6
O-Ring
SO-NB-P9
SO-NB-P9
SO-NB-P9
4
4
4
O-Ring
SO-NB-P4
SO-NB-P4
SO-NB-P4
2
2
2

Note: The GDM-211-B-11 connector assembly is not included in the solenoid assembly.
When ordering seals, please specify the seal kit number from the table below. In addition to the above o-rings,
o-rings for solenoid ass'y are included in the seal kit.
For the detail of the solenoid ass'y o-rings, see the Catalogue No. Pub. EC-1302.

List of Seal Kits

No.10

Model Numbers

Seal Kit Numbers

EDFHG-03
EDFHG-04
EDFHG-06

KS-EDFHG-03-31
KS-EDFHG-04-31
KS-EDFHG-06-31

CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.

Pub. EC-1305

POWER AMPLIFIERS / SETTING ADJUSTERS


FOR PROPORTIONAL ELECTRO-HYDRAULIC PROPORTIONAL
CONTROLS
CONTROL VALVES
Power Amplifiers
These are power amplifiers to be used exclusively to operate the electro-hydraulic proportional valves. Various type
and models on available for a variety of applications.

Type

Model Numbers

Applicable to
Control Valve

AME-D-10--20

Pressure and
Flow Control
(For 10 Sol.)

AME-D-S--32

Flow Control
(For 40 Sol.)

DC Input
AME-D2-H1--12
AME-D2-1010--10

Pressure and
Flow Control
(For 40 -10 Sol.)
Pressure and
Flow Control
(For 10 -10 Sol.)

SK1022---11

Pressure and
Flow Control
(For 10 Sol.)

AME-DF-S--22

Flow Control
(For 40 Sol.)

AME-T-S--22

Flow Control
(For 40 Sol.)

DC Input-Feedback

Slow Up-Down

SK1015-11
Pressure and
Flow Control
(For 10 Sol.)
AMN-D-10
DC Input
For DC Power
24 V DC
SK1091-D24-10

Directional and
Flow Control

Function

Page

By giving the command of DC voltage (0-10 V) to the amplifier,


current in proportion to that voltage will flow into the solenoid of
the control valve in order to control pressure or flow rate.
An external setting unit which makes the command voltage of 0-10
V and a DC power supply (or a function generator) are necessary,
but if a variable resistor for external setting is only one, the internal
power supply for amplifier can be used.

14
Variable
Resistor
1 k
Amplifier

Valve

Basically, this is a DC input type with a feedback operating unit. This


is for high-accuracy control and used to feedback the pressure or flow
rate converted to electric signals.

14

A slow up-down signal generator and the functions of a DC input


type are incorporated. This is used to control the pressure or flow
rate by slow up-down pattern and the command signals are given by
relay contacts, limit switches, timer contacts, etc.
An amplifier which is operated by a battery power supply (24V).
By giving the command of DC voltage to the amplifier, current in
proportion to that voltage will flow in the solenoid of the control
valve in order to control pressure or flow rate.
An external setting unit which makes the command voltage and a DC
power supply (or a function generator) are necessary, but if a variable
resistor for external setting is only one, the internal power supply for
amplifier can be used.
Variable
Resistor

18
Amplifier

Valve

SK1015 amplifier can be used in automobile construction machine.

No.1

POWER AMPLIFIERS / SETTING ADJUSTERS


FOR PROPORTIONAL ELECTRO-HYDRAULIC PROPORTIONAL
CONTROLS
CONTROL VALVES
Setting Adjusters
The setting adjuster supplies the command signal voltage to the power
amplifier. Since the setting adjuster is closely related to actual machine
operating procedure, the user generally provides this device.
Yuken makes the following standard setting adjusters for general use and
designs and manufactures special setting adjusters to order:

Type

Model Numbers

Function

Page

MC-01

This is the simplest setting adjuster, consisting of a trimmer (1 k ) and a dial.

18

MC-02

Consisting of a centre-tapped trimmer (1 k -1 k ) and a dial, this setting


adjuster is ideal for a servo system.

18

6-point Setting Adjuster

AMC-V6-S--10

Six trimmers are incorporated, so it is possible to set six points.

19

Multifunction Slope
Controller

AMC-T-20

This multifunction slope controller generates any desired 2-channel analog voltage
pattern outputs. It can also be used with slope-proportional and time-proportional
systems.

20

Manually Operated
Setting Adjuster

Instructions for Power Amplifiers


The power amplifiers should be kept away from hot and humid conditions which may deteriorate some components of
the power amplifiers. They also should be installed in the clean and dry place where the vibration is minimal.
Please avoid to install the power amplifiers in the complete enclosure or get them enclosed totally as they need to radiate
the heat from semiconductors or ICs inside.
Please use shielded wires for input signal transmission to prevent the amplifiers from any interference such as noise from
outside.

No.2

Power Amplifiers
For 10 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers are used to drive the 10 series proportional


electro-hydraulic pressure and flow control valves.

Model Number Designation

AME

-D

-10

-100

-20

Series
Number

Type of Function

Coil Resistance
of Valve

Power Supply

Design
Number

AME

D : DC Input Type

10 : 10

100 : 100 V AC
200 : 200 V AC

20

Applicable to Valve

SK1022

-A

Series Number

-100

Type of Function

SK1022 :
DC Input-Feedback
Type

-11

Power Supply

A : Polarity of Feedback
Voltage...(-)

100 : 100 V AC

B : Polarity of Feedback
Voltage...(+)

200 : 200/220 V AC

Design
Number

11

SK1015 :
DC Input Type
for DC Power
Supply

11

Name of Valve

Model Numbers

Pilot Relief Valves

EDG-01

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

Use with 24 V DC since this is for a battery power supply.

Specifications
Model No.

AME-D-10--20

SK1022-A--11

SK1022-B--11

SK1015-11

DC Input Type

DC Input
Feedback Type

DC Input
Feedback Type

DC Input Type

Max. Output Current

1 A (10 Solenoid)

1 A (10 Solenoid)

1 A (10 Solenoid)

0.9 A (10 Solenoid)

Max. Input Voltage

+ 10 V DC

+ 10 V DC

+ 10 V DC

+ 10 V DC

0 to -10V

0 to +10V

Description
Type of Fuction

Feedback Voltage
10 k

50 k

50 k

50 k

Max. Gain

1A/5V

1 A / 0.5 V

1 A / 0.5 V

0.9 A / 5 V

Dither

Variable

Fix

Fix

Fix

0.2 mA /C

0.2 mA /C

0.2 mA /C

1 mA /C

Input Impedance

Temperature Drift (Max.)


Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

100 V AC, 200 V AC


(50/60 Hz)

100 V AC, 200/220 V AC 10% (50/60 Hz)

22-30 V DC

55 VA

45 VA

45 VA

25 VA

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

1 k

1 k

1 k

10 k

2.1 kg (4.6 lbs.)

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

0.4 kg (.88 lbs.)

Serviceable Range; 100 V AC can be used from 90 to 132 V AC, 200 V AC can be used from 180 to 264 V AC.

Instructions
Power supply for the setting adjuster can be provided from this power amplifier, but for only one. However, please use
the variable resistor or potentiometre of which impedance is 1 k (in case of model SK1015, use 10 k ) for the
setting adjuster.

No.3

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D-10--20

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5

Setting Adjuster
MC-01

220

+12V

DITHER
MAX

MIN

1 k

SOL

7
8
9
10
11
12

8
10

11

12

Power Supply

Ammeter
(Output Current)

Max. Adjuster

Zero Adjuster

Name
Input Signal
Input Signal

IN
COM

Input Signal

COM

Internal Power Supply


(10 V at 1 k )
Output to Valve
Solenoid

+12 V
SOL

Ground
Power Supply
100/200 V AC

Terminal Board
(Refer to table above)

MIN

199(7.83)

MAX

Power Fuse

189(7.44)

CURRENT
MONITOR

IN
COM

COM

12V

Supply Switch
F

SOL

DITHER

POWER

4.5(.18) Dia. Through


4 Places

1
2
3
4
5
6
7
8

G
AC

9
10
11
12

178(7.01)

POWER AMP

Dither Adjuster
Indicator Lamp

70
(2.76)
80
(3.15)

25
(.98)

170
(6.69)
185.5
(7.30)

76
(2.99)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

DIMENSIONS IN
MILLIMETRES (INCHES)

No.4

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
SK1022-A--11
B

Terminal Board

[ Example Diagram ]
Setting Adjuster
MC-01
470

10

15V
REF

DITHER

1
GAIN

1 k

SOL
8

11
3

F.B

NULL

Terminal
Number
1
2
3
4
5
6
7
8
9

Name

Pressure
Sensor

12

13

14

Output to Valve
Solenoid

SOL

Terminal Board
(Refer to table above)

GAIN

199(7.83)

NULL

FB

189(7.44)

REF COM

Feedback 3
Adjuster
Gain Adjuster

SOL

Power Fuse
100 V AC : 2A
200/220 V AC :
1A

Indicator Lamp

+15V
G
AC

POWER

F1

8 REF
9 COM

1
2

10 F.B
11COM
12
13

3
4
5
6

14

178
(7.01)

Check Terminal
3 Places

Zero 2
Adjuster
Supply
Switch

Power Supply
100 V AC, 200V AC : 13, 14
220 V AC : 12, 14

Ammeter (Output Current)

Reference
Adjuster

+15V

Ground

11
12
13
14

Power Supply

REF
COM
F.B
COM

Power Supply for


Setting Adjuster
(10 V at 1 k)

10

Input Signal
Input Signal
Feedback Signal
Feedback Signal

Output
Fuse (2A)

F2

4.5(.18) Dia.
Through
4 Places

1.
2.
3.
4.

120
(4.72)

240(9.45)

105(4.13)
125(4.92)

22
(.87)

260(10.24)

Adjustment of upper limit of usable range


Adjustment of lower limit of usable range
Adjustment of feedback voltage ratio
Adjustment of input voltage ratio

DIMENSIONS IN
MILLIMETRES (INCHES)

SK1015-11

1 k

Blue

White

Black

1
2
3
4
5
6
7

GAIN

Blue

Black
10 k

100(3.94)

NULL

Red

SOL

4(.16) Dia.
Through
4 Places

45
(1.77)

3
(.12)

75(2.95)
85(3.35)

Setting
Adjuster
Yellow

120(4.72)

Lead Wire
Approx.
200
(7.87)

[ Example Diagram ]

24 V DC

Zero Adjuster

Gain Adjuster

Lead Wire Detail


1
2
3
4
5
6
7

White........Plus of 24 V DC
Black........Zero of 24 V DC
Blue..........
Blue.......... Output to Valve Solenoid
Yellow......15 V Power Supply for Setting Adjuster (10 V at 10 k)
Red...........Input Signal
Black........Zero of Input Signal

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

No.5

Power Amplifiers
For 10 Series Control Valves

PROPORTIONAL
CONTROLS

Specifications / Others
Compact power amplifiers for 10 proportional solenoids. The power
supply is 24 V DC. It uses a new circuitry to be slow to heat.

Model Number Designation

AMN

-D

-10

Series Number

Type of Function

Design
Number

AMN

D : DC Input Type

10

Specifications

Applicable to Valve

Model No.

Name of Valve

AMN-D-10

Description
Type of Function

DC Input Type

Max. Output Current

1 A (10 Solenoid)

Power Input (Max.)

+ 10 V DC
10 k

Input Impedance
Max. Gain

1A/5V

Dither

Variable

Temperature Drift (Max.)

0.2 mA /C

Power Supply

24 V DC (20 - 30 V DC)

Max. Input Power

25 W

Ambient Temperature

Model Numbers

Pilot Relief Valves

EDG-01

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

0 - 50C (32 - 122F)


1 k

External Setting Resistance


Approx. Mass

0.2 kg (.44 lbs.)

AMN-D-10

DIMENSIONS IN
MILLIMETRES (INCHES)

[Example Diagram]
Setting Adjuster
MC-01

MIN

+12V

3.5(.14) Dia.
Through
2 Places

5
SPAN

1 k

SOL

Zero Adjuster

Power Supply
Span Adjuster

POWER

100(3.94)

SPAN

90(3.54)

MIN

DITHER

Terminal Board
Terminal
Number
1
2
3
4
5
6
7
8

No.6

1 2 3 4 5 6 7 8

Name
Power Supply
Power Supply
Ground
Internal Power Supply
Input Signal
Input Signal
Output to Valve
Solenoid

+24 V
0V
G
+12 V
IN
COM
SOL

Terminal Board
(Refer to table on
the left.)
2.5
(.10)
30
(1.18)

50
(1.97)
60
(2.36)

Indicator
Lamp

Power Amplifiers
For 40 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers are used to drive the 40 series proportional


electro-hydraulic flow control valves.

Model Number Designation

AME
Series
Number

-D

-S

-100

-32

Type of Function

Type of
Mounting

Power Supply

Design
Number

S : Panel
Mounting
Type

100 :
100 V AC
200 :
200/220 V AC

32

D : DC Input Type
AME

DF : DC Input
Feedback Type
T : Slow Up Down
Type

22
22

Applicable to Valve
Name of Valve

Model Numbers

40 Series
Flow Control Valve

EFG -02/03/06/10
EFCG

40 -10 Series
Flow Control and
Relief Valve

EFBG-03/06/10

Specifications
Model No.
Description
Type of Function

AME-D-S--32

AME-DF-S--22

AME-T-S--22

DC Input Type

DC Input Feedback Type

Slow Up Down Type

Max. Output Current

0.8 A (40 Solenoid)

0.8 A (40 Solenoid)

0.8 A (40 Solenoid)

Max. Input Voltage

+ 10 V DC

+ 10 V DC

Feedback Voltage
Input Impedance

0 to -10 V
10 k

50 k

0.8 A / 5 V

0.8 A / 5 V

Slow Up Down Range


Max. Gain
Dither
Temperature Drift (Max.)

0.05 to 1 s /100 mA
Fix

Fix

Fix

0.2 mA /C

0.2 mA /C

0.2 mA /C

100 V AC, 200/220 V AC 10% (50/60 Hz)

Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

90 VA

90 VA

90 VA

0-50C (32-122F)

0-50C (32-122F)

0-50C (32-122F)

1 k

1 k

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

4.5 kg (9.9 lbs.)

Instructions
When DC input type (AME-D-S) or DC input-feedback type (AME-DF-S) power amplifier is used, power supply for
the setting adjuster can be provided from this power amplifier, but for only one. However, please use the variable
resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.7

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D-S--32

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5
6
7
8
9

Setting Adjuster
MC-01

10 470

15V
DITHER

GAIN

1
1 k

NULL

SOL

9
11

12

Name

13 14

Output to Valve Solenoid SOL


Power Supply for Setting
+15 V
Adjuster (10 V at 1 k )
Ground
G

10

Power Supply

IN
COM

Input Signal
Input Signal

11
12
13
14

Power Supply
100 V AC, 200 V AC: 13, 14
220 V AC: 12, 14

Ammeter
(Output Current)

NULL

GAIN

Supply Switch

199(7.83)

Gain Adjuster
189(7.44)

Zero Adjuster

POWER

4.5(.18) Dia.
Through
4 Places

Indicator
Lamp
105
(4.13)
125
(4.92)

240
(9.45)
260
(10.24)

22
(.87)

Terminal Board
(Refer to table above)

8
9
10
11
12
13
14

SOL
+15V
G

DIMENSIONS IN
MILLIMETRES (INCHES)

Power Fuse
100 V AC: 3 A
200/220 V AC: 1.5 A

AC

1
2
3
4
5
6
7

IN
COM

F1

F2

120
(4.72)

View Arrow X

No.8

178(7.01)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range

Output
Fuse (1.5 A)

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-DF-S--22

Terminal Board
Terminal
Number

[Example Diagram]
Setting Adjuster
MC-01

10

470

15V
DITHER

REF

1
GAIN

1 k

SOL

8
11
F.B

NULL

Name

1
2
3
4
5
6
7
8
9

Input Signal
Input Signal
Feedback Signal
Feedback Signal

Output to Valve Solenoid SOL


Power Supply for Setting
+15 V
Adjuster (10 V at 1 k )
Ground
G

10

Sensor

12

13

14

11
12
13
14

Power Supply

IN
COM
F.B
COM

Power Supply
100 V AC, 200 V AC: 13, 14
220 V AC: 12, 14

Ammeter
(Output Current)
Check Terminal
3 Places
Reference Adjuster

Feedback Adjuster

Supply Switch

REF COM

NULL

FB

GAIN

POWER

199(7.83)

189(7.44)

Zero Adjuster

Gain Adjuster

Indicator Lamp

4.5(.18) Dia.
Through
4 Places
240
(9.45)
260
(10.24)

22
(.87)

Terminal Board
(Refer to table above)

1. Adjustment of upper limit of usable range


2. Adjustment of lower limit of usable range
3. Adjustment of feedback voltage ratio
4. Adjustment of input voltage ratio

8
9

SOL

10
11
12
13
14

+15V
G

DIMENSIONS IN
MILLIMETRES (INCHES)

AC

Power Fuse
100 V AC: 3 A
200/220 V AC: 1.5 A

F1

REF

1
2

COM
F.B

3
4
5
6
7

COM

F2

178(7.01)

105
(4.13)
125
(4.92)

Output
Fuse (1.5 A)

120
(4.72)

View Arrow X

No.9

Power Amplifiers
For 40 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-T-S--22

Terminal Board

[Example Diagram]

1
2
3
Limit Switch

4
10

CH1

CR1

DITHER

Input Command

CR1

Input Command

CR2

Input Command

CR3

Input Command

CR4

SOL

CR3

Output to Valve Solenoid

SOL

6
7

CH2

Sequence Holding
Circuit

Name

CR2

CR4

Trminal
Number
1

14

10

Input Command

Power Supply

11

Ground

12 13

12

CR. COM
G

Power Supply

13

100 V AC, 200 V AC: 13, 14

14

220 V AC: 12, 14

Ammeter (Output Current)


Indicator Lamp
(CH2)

Terminal Board
(Refer to table above)

Indicator Lamp
(CH1)

MIN

MAX

MIN

UP

DOW

UP

DOW

POWER

NULL

Power Fuse
100 V AC : 3A
200/220 V AC :
1.5 A

Null Adjuster

4.5(.18) Dia.
Through
4 Places
Indicator Lamp

105(4.13)
125(4.92)

F1

F2

Output
Fuse
(1.5 A)

120
(4.72)

240(9.45)
260(10.24)

22
(.87)

1
2
3
4
5
6
7

8
9
10
11
12
13
14

178
(7.01)

Supply Switch

MAX

189(7.44)
199(7.83)

CH2 Adjuster

CH1 Adjuster

[Output Current Pattern]


CH1
(Channel 1)
Current
MAX.1

DOWN.1

UP.1
NULL

DIMENSIONS IN
MILLIMETRES (INCHES)

CH2
(Channel 2)
DOWN.2

MAX.2
UP.2

MIN.1

MIN.2
Time
Terminal
1 & 10 in Short-Circuit

CR1.ON

2 & 10 in Short-Circuit

CR2.ON
CR3.ON
CR4.ON

3 & 10 in Short-Circuit
4 & 10 in Short-Circuit

Note: 1. CR1 to CR4: Relays in the power amplifier.


The output patterns CH1 and CH2 can not be obtained simultaneously nor can they be transmitted halfway to
another pattern.
2. The words such as MAX, MIN, UP and DOWN show the volume adjustment of the power amplifier.

No.10

Power Amplifiers
For 40 Series Control Valves
How to Calculate Accelerating and Decelerating Time

PROPORTIONAL
CONTROLS

How to Calculate Accelerating and Decelerating Time (Example)

Question: Wish to accelerate and decelerate the actuator in between 5 L/min (1.32 U.S. GPM) and 25 L/min
(6.6 U.S. GPM) in the use of proportional flow control valve model EFG-02-30.
In such case, what are the maximum and minimum time adjustable for the acceleration and
deceleration?
Answer: The input current for EFG-02-30 at the flow rate of 5 L/min (1.32 U.S.GPM) and 25 L/min (6.6
U.S. GPM) can be obtained respectively from the chart below. The chart shows:
Input current at 5 L/min (1.32 U.S. GPM)
300 mA
Input current at 25 L/min (6.6 U.S. GPM)
520 mA
Then, the difference between the above two can be obtained with the following formula:
520 mA-300 mA=220 mA
While, the specification for the model AME-T-S shows the amplifier's gradient for acceleration
or deceleration as being between 0.05 s/100 mA and 1.0 s/100 mA (which means that the minimum
time is 0.05 second and the maximum time is 1.0 second for every 100 mA variation).
Therefore, the minimum and maximum adjustable time can be obtained as follows:

220 mA
0.05 second = 0.11 second (Minimum)
100 mA
220 mA
1.0 second = 2.2 second (Maximum)
100 mA
The result above are as illustrated on the below.

H
[Flow Pattern]

[Input Current vs. Flow]


EFG-02

U.S.GPM L /min
30
8

L /min
(U.S.GPM)

Flow Rate

25 L /min
(6.6 U.S.GPM)

25

5 L /min
(1.3 U.S.GPM)

Min.
0.11 s
Max. 2.2 s

Min.
0.11 s

Time s

Max. 2.2 s

Flow Rate

6
5
4
3

20
15
10

2
1
0

5
0
0

10

200 300 400 500

Input Current

600

mA

No.11

Power Amplifiers
For 40 -10 Series Control Valves

PROPORTIONAL
CONTROLS

Specifications / Others

These power amplifiers are specially designed to combine and


incorporate the functions of pressure control (10 solenoid) and
flow control (40 solenoid) into one and can be used for the
proportional electro-hydraulic flow control and relief valves of
which model numbers are as shown below.

Model Number Designation


AME

-D2

-H1

Series Number

Type of Function

Type of Mounting

AME

D2: DC Input Type

H1: Wall Tapestry Type

-100

-12

Power Supply

Design
Number

100: 100 V AC
200: 200/220 V AC

12

Applicable to Valve
Name of Valve
40- 10 Series
Flow Control and
Relief Valve

Model Numbers
03-125
EFBG-06-250-C
H
10-500

Specifications
Model No.
Description
Type of Function
Max. Output Current
Max. Input Voltage
Input Impedance
Max. Gain
Dither
Temperature Drift (Max.)
Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

AME-D2-H1--12
Flow Controls (40 Solenoid)
Pressure Controls (10 Solenoid)
DC Input Type
DC Input Type
1 A (10 Solenoid)
0.8 A (40 Solenoid)
+10 V DC
+10 V DC
10 k
10 k
0.8 A / 5 V
1A/5V
Fix
Fix
0.2 mA /C
0.2 mA /C
100 V AC, 200/220 V AC 10% (50/60 Hz)
130 VA
0-50C (32-122F)
1 k
1 k
5.6 kg (12.3 lbs.)

Instructions
Power supply for the setting adjuster up to 2 set can be provided from this power amplifier. However, please use the
variable resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.12

Power Amplifiers
For 40 -10 Series Control Valves
Installation Drawing
AME-D2-H1--12

PROPORTIONAL
CONTROLS

Terminal Board
Terminal
Number

[Example Diagram]

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Flow Setting
Adjuster
20

DITHER

12V

19

Flow Control Valve

SPAN

9
17

MIN

18

DITHER
SPAN

8
6

40 SOL

Pres.Control Valve
10 SOL

TOFF TON
MIN

Pres. Setting
Adjuster

Terminal Board
(Refer to the table
on the right above.)

Pres. Zero-Point Adjuster

Flow Zero-Point Adjuster

Name
Power Supply
100 V AC, 200 V AC: 1, 2
220 V AC: 1, 3
G

Ground

Output to Pressure Control


Valve (10 ) Solenoid
PR. SOL
Ammeter
Output to Flow Control
Valve (40 ) Solenoid
Ammeter
Common

-12 V OUT
Common
+12 V OUT
Common
Input Signal for PRES.
Input Signal for FLOW
+12 V OUT

FL. SOL
COM

-12 V
COM
+12 V
COM
PR.IN
FL.IN
+12 V

F1

10

20

19

18

17

16

15

14

13

12

11

PRES FLOW

2
4

MIN
SPAN
T ON
T OFF

POWER

F2

Pres. Span Adjuster


Flow Span Adjuster

174
(6.85)

188(7.40)

200(7.87)

POWER
AMPLIFIER

Pres. Rising Time Adjuster


Indicator Lamp
Pres. Falling Time Adjuster

Flow Output Fuse


1.5 A
Pres. Output Fuse
2A

6(.24)
60
(2.36)

100(3.94)
220(8.66)

Supply Switch
145
(5.71)

1. Minimum Pressure Setting


2. Variable Pressure Range Setting
3. Minimum Flow Setting
4. Variable Flow Range Setting

DIMENSIONS IN
MILLIMETRES (INCHES)

No.13

Power Amplifiers
For 10 -10 Series Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

These power amplifiers can drive two solenoid of 10 load simultaneously


or separately, and the control can be done in the same way even though the
object is separated by pressure system and flow rate system. Although the
display of control unit on the front panel is PRESS and FLOW , they
are exactly the same circuit, so there is no distinction between the two system
when used.

Model Number Designation

AME
Series
Number
AME

-D2
Type of Function
D2 :
DC Input Type

Applicable to Valve

-1010

-100

Coil Resistance
of Valve
1010 : 10 2

Power Supply
100 : 100 V AC
200 : 200/220 V AC

-10
Design
Number

Model No.
Type of Function

AME-D2-1010--10
1 A (10 Solenoid)

Max. Input Voltage

+ 10 V DC

Max. Gain
Dither
Temperature Drift (Max.)
Power Supply
Power Input (Max.)
Ambient Temperature
External Setting Resistance
Approx. Mass

Relief Valves

EBG-03
EBG-06
EBG-10

Reducing and
Relieving Valves

ERBG-06
ERBG-10

10 Series
Flow Control Valves

EFG - 03
EFCG 06

10 -10 Series
High Flow Series
Flow Control and
Relief Valves

EFBG-03
EFBG-06
EFBG-10

DC Input Type

Max. Output Current


Input Impedance

Model Numbers
EDG-01

10

Specifications
Description

Name of Valve
Pilot Relief Valves

10 k
1A/5V

Applicable to Piston Pump


Name of Pump

Variable 100-300 mA
0.2 mA /C
100 V AC, 200/220 V AC 10% (50/60 Hz)
120 VA
0-50C (32-122F)
1 k
4.3 kg (9.5 lbs.)

"A" Series Variable


Displacement
Piston Pump
Proportional
Electro-Hydraulic
Load Sensing Type

Model Numbers
A16
A22
- -R-04
A37
A56
A70
A90 --R-04
A145
Also, double pumps
combined with the
models listed above
and fixed displacement vane pumps.

Instructions
Power supply for the setting adjuster up to 2 set can be provided from this power amplifier. However, please use the
variable resistor or potentiometre of which impedance is 1 k for the setting adjuster.

No.14

Power Amplifiers
For 10 -10 Series Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
AME-D2-1010--10

Terminal Board
Terminal
Number
1

[Example Diagram]

Flow
Setting Adjuster
17
16

DITHER

+12V
SPAN

MIN

14
15

FL.
SOL

DITHER
SPAN

MIN

PR.
SOL

Pressure
Setting Adjuster

Power Supply

Name
Power Supply

100 V AC, 200 V AC: 1, 2

220 V AC: 1, 3
G

Ground

Output to Pressure Control

Valve Solenoid

Ammeter

Output to Flow Control

Valve Solenoid

10

Ammeter

PR.SOL

FL.SOL

11

12 V OUT

12

Common

12 V
COM

13

+12V OUT

+12 V

14

Common

COM

15

Input Signal for PRES.

PR. IN

16

Input Signal for FLOW

FL. IN

17

+12V OUT

+12 V

Pres. Dither Adjuster


Pres. Span Adjuster

Terminal Board
(Refer to table on
the right above.)

Pres. Zero-Point Adjuster

Flow Zero-Point Adjuster

Flow Span Adjuster

POWER AMPLIFIER

6 +12V

13

5 COM

12

4 12V

11

PR
SOL
GND

Flow Dither Adjuster

FLOW

PRESS

15
MIN

14

Indicator Lamp

SPAN

DITHER

3
AC220V

2
AC200V

POWER

F3
US

F2
US

F1
US

188(7.40)

200(7.87)

16

AME-D2-1010-200-10

17

FL
IN
PR
IN
COM

FL
SOL

+12V

175
(6.89)

10

145
(5.71)

6(.24)
60
(2.36)

100(3.94)
220(8.66)
Power Fuse
100 V AC : 2A
200 V AC :1A

Supply Switch
Pres. Output Fuse
(1.5A)
Flow Output Fuse
(1.5A)

DIMENSIONS IN
MILLIMETRES (INCHES)

No.15

Power Amplifiers
For Directional and Flow Control Valves
Specifications / Others

PROPORTIONAL
CONTROLS

Model Number Designation

SK1091

-D24

-10

Series Number

Power Supply

Design Number

SK1091

D24 : 24 V DC

10

Applicable to Valve
Name of Valve

Model Numbers

Directional and
Flow Control Valve

03
EDFHG-04
06

Specifications
Model No.
Description

SK1091-D24-10

Max. Output Current

1 A (10 Solenoid)

Max. Input Voltage

-10 V DC for SOL a


+10 V DC for SOL b

Input Impedance
Max. Gain

10 k
1 A / 5 V

Dither

Variable

Delay Time Adjustment


Range

0.15-3 s

Temperature Drift (Max.)


Power Supply
Required Current
Power Input (Max.)

0.2 mA /C
24 V DC (21-28 V Included Ripple)
More than 1.5 A
25 W

Ambient Temperature

0-50C (32-122F)

Ambient Humidity

Less than 90%RH

External Setting Resistance


Approx. Mass

2 k
1.0 kg (2.2 lbs.)

Instructions
Power Supply for the Setting Adjuster
Power supply for the setting adjuster can be provided from this power amplifier, but for only one. However, please use
the variable resistor or potentiometre of which impedance is 2 k for the setting adjuster.
Power Switch
The power amplifier has no power supply switch. As soon as it is connected to a power supply , it comes to be alive.
Provide a power switch externally.

No.16

Power Amplifiers
For Directional and Flow Control Valves

PROPORTIONAL
CONTROLS

Installation Drawing
SK1091-D24-10

MINa

Setting Adjuster
4

For SOL a

DOWNa

UPa

MC-02

SPANa

+12V

8 SOLa

1
6
5
2 k

Output Current (A)

[Input-Output Characteristics]

[Example Diagram]

DELAY

-12V

SPAN a

10 SOLb

UPb

MIN a

11
DOWNb SPANb

14
24V

12

-V

DITHER

MINb

For SOL b

SPAN b
MIN b

Approx. 0.1V

Input Voltage

+V

0V

13

Power Supply

Terminal Board
Terminal
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14

Name
Input Signal
Input Signal

IN
COM

Power Supply for Setting Adjuster


Power Supply for Setting Adjuster
Power Supply for Setting Adjuster

+12V
COM
-12V

Input Voltage 0

Output to Valve Solenoid

SOL a

Output Current 0

Output to Valve Solenoid

SOL b

[Delay Function]

+V

-V

24 V
0V
FG

Power Supply
Power Supply
Ground

UP b
DOWN b

UP a
DOWN a

DIMENSIONS IN
MILLIMETRES (INCHES)

Indicator Lamp
Delay Time
Adjuster
for SOL a
POWER

SOL a, b
Indicator Lamp
1

SOLa
SOLb

Delay Time
Adjuster
for SOL b

DOWNa

150(5.91)

SPANb

14

13

12

11

10

SPANa

180(7.09)

DOWNb

166(6.54)

UPb

UPa

Span Adjuster

MINa
MINb

DITHER

Zero-Point Adjuster
Terminal Board
(Refer to the table
on the above.)
6
(.24)

Dither Adjuster

10
(.39)

100
(3.94)

48
(1.89)

No.17

Setting Adjusters
Manually Operated Setting Adjusters
Installation Drawing

PROPORTIONAL
CONTROLS

MC-01
[Example Diagram]
Setting Adjuster
(MC-01)
3

3
Clockwise
Rotation
2

1k

[Mounting Panel]
M4 Thd.
4 Places

Power Amplifier
(AME-D-10)
6
7

62(2.44)
70(2.76)

[Electric Circuit]

10
1

11

12

Power Supply
62(2.44)
70(2.76)

70

20

80

10

3
2

90
0

60
(2.36)

60

30

80(3.15)

50

5(.20)

40

70(2.76)

4.5(.18) Dia.
Through
4 Places

2 3 4

100

YUKEN MODEL MC-01

70(2.76)

2.3(.09)

80(3.15)

30
(1.18)

60
(2.36)

60
(2.36)

10
(.39)

DIMENSIONS IN
MILLIMETRES (INCHES)

MC-02
[Example Diagram]

This setting adjuster is for using positive and


negative voltages to the right and left of the zero
point. Most suitable for servo systems.
Please contact us for usage details.

M4 Thd.
4 Places
Power Amplifier
SK1091-D24-10
4
+12V
1
Input
6
12V
5 0V

Setting Adjuster
(MC-02)
3
2

[Electric Circuit]

1
4

Servo Amplifier

1k

3
Clockwise
Rotation
2

1k

2k

[Mounting Panel]

62(2.44)
70(2.76)

[How to Use]

62(2.44)
70(2.76)

40
60

60

3
2
1

80

80
100

60
(2.36)

20 INC.

40

80(3.15)

70(2.76)

DEC. 20

5(.20)

4.5(.18) Dia.
Through
4 Places

2 3 4

100

YUKEN MODEL MC-02

70(2.76)
80(3.15)

No.18

2.3(.09)
30
(1.18)

60
(2.36)

10
(.39)

60
(2.36)

Setting Adjusters
6-Point Setting Adjusters

PROPORTIONAL
CONTROLS

Installation Drawing
AMC-V6-S--10

Terminal Board

Power Supply
100............100 V AC
200............200 V AC
220............220 V AC

[Electric Circuit]
12
AC
Power Supply

10 VDC
Power
Supply

13
14

10V

VR1

VR2 VR3 VR4

VR5

VR6

Terminal
Number
1

1 OUT (VR1)

2 OUT (VR2)

3 OUT (VR3)

4 OUT (VR4)

5 OUT (VR5)

6 OUT (VR6)

Name

0V

COM

0V

9
11

8(0V)

10

11

Ground

12
13

[Example Diagram]
Relay Circuit

Setting Adjuster
(AMC-V6-S)

1
2
3
4
5
6
8
13 14

14

Power Supply
85-265 V AC

Power Amplifier
(AME-D-S)

SOL

13 14 11

11
AC
Power Supply

Supply Switch

8
9
10
11
12
13
14

189(7.44)
199(7.83)

F1

POWER

70(2.76)
80(3.15)

1
2
3
4
5
6
7

178
(7.01)

Terminal Board
(Refer to the table above)

4.5(.18) Dia. Through


4 Places

Adjusting Dial
6 Places

Indicator
Lamp

22
(.87)

240(9.45)
260(10.24)

76
(2.99)
Power Fuse (1A)

DIMENSIONS IN
MILLIMETRES (INCHES)

No.19

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Specifications / Others
This controller can generate any desired 2-channel analog voltage pattern outputs
and can be used with slope-proportional and time-proportional systems.

Model Number Designation

AMC

-T

-20

Series Number

Type of Function

Design
Number

AMC : Setting Adjuster

T : Acceleration/deceleration signal type


(Slope Controller)

20

Specifications
Model No.

AMC-T-20

Description
Number of Output Channels

2 channels (A, B)

Maximum Output Range

0 - +5 V , 0 - 5 V, 0 - +10 V, 0 - 10 V (The settings are DIP switch selectable)

Two Categories of Slopes

Slope-constant
With a level change, the slope will not change (but arrival time changes.)
Time-constant
With a level change, the time will not change (but the slope changes.)

Acceleration/Deceleration
Signal Type

: 1 Type
4 Types Polygonal Line Signal
Curve Compensation Signal : 3 Types

Maximum Slope Time

The level and slope settings are variable in 0.1% units from 0 to 99.9%
Mode 1, 4-bit binary code input, 15 patterns
Mode 2, 6-bit binary code input, 63 patterns
Mode 3, Timer control, 9 patterns (4 variations)

Control Mode
Number of Preselected Patterns

Control Input Signal


Control Output Signal
Data Save
Power Supply
Power Input
Ambient Temperature
Ambient Humidity
Approx. Mass
Note:

to be selected
by DIP switch

5 s , 20 s, 50 s, 100 s (The settings are DIP switch selectable)

Setting Resolution

Stop Mode
Applicable Only for
Control Mode 1

ON

: The stop mode is to retain the state of controller output at the instant an external input signal is
interrupted. When the external signal is input again, the operation is resumed from the retained state.
OFF : When external input signal is interrupted, function goes back to the initial setting (Pattern No.0).
Current input type, 10 mA /bit max.
Usable as a voltage input type (voltage range: 8 to 48V DC) Photocoupler insulation input
Output from transister open collector
Max. 30V, 50 mA
EEP-ROM (Battery not needed)
100/200 V AC, 50/60 Hz (85-260 V AC)
Less than 10 VA
0-50C (32-122F)
Less than 85%RH (Bedewing must be avoided)
1 kg (2.2 lbs.)

Indicates preset conditions.

Instructions
Since this controller incorporates a micro computer, do subject it to undue electrical noise.

No.20

to be selected
by DIP switch

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Control Modes / Setting Example / Slope Type


Control Modes

Setting Example

One among the following 3 types of control modes


can be chosen by changing DIP swicth.

Control Mode 1

Control Mode 1
Channels A and B generate optional slopes
independently each other.
Channel-A
Code Input
Pattern No.

0000

0001

0010

0011

0000

A Channel

Code Input

Pattern Setting %
No. Level Slope

Remarks

A8

A4

A2

A1

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

99.9

40.0

Cylinder forward
acceleration

OFF

OFF

ON

OFF

-80.0

60.0

Cylinder backward
acceleration

OFF

OFF

ON

ON

10.0

50.0

Cylinder forward
deceleration

ON

ON

ON

ON

15

10.0

10.0

Stop

Output
Channel-B
Code Input

0000

0101

0100

0000

Pattern No.

Backward

Forward

Output
Pattern 3

Pattern 1
{
Level
99.9%

Output

Control Mode 2
A slope is generated by a strobe signal (signal for
change to next signal). Channels A and B operate
synchronously.

Pattern 2

Level

Slope Level
50.0% 10.0%

Slope
40.0%

-80.0%

|
0000 0001

0010

0011

0000

Slope
Code Input

Code Input
Strobe Signal
Pattern No.

60.0%

ON
A1

ON

ON

A2

Channel-A
Output

Slope Type
One among the following 4 types can be chosen by changing
DIP switch.

Channel-B
Output

Type 1
(%)
100

Straight
Slope Waveform

50

Channel-A

1.0

1.1

1.2

1.3

Output

Output

3.0 3.1

3.2 3.3 3.4 3.5 3.6 3.7 3.8

3.9

Type 3

Type 4
(%)
100

50
R
0

25

The 0 to 25% and


75 to 100% portions
of the slope
waveform are
rounded with arcs.
Time

Two portions above


and below 50% of
the waveform are
rounded with arcs.
Time

Output Voltage

Pattern No.

Output Voltage

Start Signal 3

50

Time

(%)
100

Channel-B

75

Start Signal 1
Pattern No.

Output Voltage

Output Voltage

Control Mode 3
The internal timer is activated by a start signal,
causing the slopes to be generated successively in
memory.
Channels A and B operate independently.

Type 2

(%)
100

R
50
30
0

Two portions above


and below 30% of
the waveform are
rounded with arcs.
Time

No.21

Setting Adjusters
Multifunction Slope Controllers

PROPORTIONAL
CONTROLS

Installation Drawing
AMC-T

[Example Diagram]
AMC-T-20

(Ex.)
EHDFG-03

Sequence Controller
A1

A2

A4

A8

B1

B2

9
10

B8

11

D/A

IN

D/A

DC24V

EHDFG-03
B

RAM
a
FG

20

IN

19

DC
Power
Supply

COM 12

CO.A 13

3 B out

18

Isolation
Power
Supply

IN

ROM

1 A out
2 COM

IN
B4

CPU

AC
85-260V

C
DC24V

Voc

CO.B 14
M.SV 15

OUT

ALM. 16
17
DOC

DIMENSIONS IN
MILLIMETRES (INCHES)

DC Power
Supply

Terminal Board
Name
A out
COM
B out
A1
A2
A4
A8
B1
B2
B4

Channel A Output
Common
Channel B Output
Code Input
Code Input
Code Input
Code Input
Code Input
Code Input
Code Input

Terminal
Number
11
12
13
14
15
16
17
18
19
20

Name

D : Slope Display
M: Channel B Output

1
2
3
4
5
6
7
8
9
10
11
12
13
POWER
14
ON
15
16
OFF
17 18 19 20

A
B

AMC-T

199(7.83)

189(7.44)

Indicator Lamp
D : Time Display
DIP switch
D : Alteration of Level
Slope Time Values

Panel Operating Key


Data Set (D)
Monitor (M)
70
(2.76)
80
(3.15)

No.22

AC

Power Supply

D : Level Display
M: Channel A Output

Pattern No.
Display

D : Channel
Selection

B8
DCOM
CO.A
CO.B
M.SV
ALM.
DOC
FG

Code Input
Code Input Common
Coincidental Output Signal with "A"
Coincidental Output Signal with "B"
Data Save Signal
Alarm Signal Output
Output Common
Ground

D : Pattern No.
Designation After
Channel Selection

4.5(.18) Dia. Through


4 Places

25
(.98)

60
(2.36)
72
(2.83)

178(7.01)

Terminal
Number
1
2
3
4
5
6
7
8
9
10

Terminal Board
(Refer to table above)

Supply
Switch

Setting Adjusters
Multifunction Slope Controllers
Interchangeability between Current and New Design

PROPORTIONAL
CONTROLS

Interchangeability between Current and New Design


Specifications
Specifications unchanged unless specified below.
Model No.

New : AMC-T-20

Current : AMC-T-10

Output from transister open collector


Max. 30 V, 50 mA

Output from transister open collector


Max. 30 V, 10 mA

Description
Control Output Signal

: 1 Type
4 Types Polygonal Line Signal
Curve Compensation Signal : 3 Types

Slope Types

to be selected
by DIP switch

1 Type : Polygonal Line Signal

Stop Mode
(Applicable only for Control Mode 1)

ON, OFF

Data Save

EEP-ROM Battery not needed

Battery Required

Approx. Mass

1 kg (2.2 lbs.)

1.8 kg (4.0 lbs.)

Terminal
The following are differences between current and new.
Name

Terminal
Number

New : Design 20

Current : Design 10

13

Coincidental Output Signal with "A"


"CO.A"

Coincidental Output Signal with "A"


"DO1"

14

Coincidental Output Signal with "B"


"CO.B"

Coincidental Output Signal with "B"


"DO2"

15

Data Save Signal


"M.SV"

16

Alarm Signal Output


"ALM."

Remarks

Abbreviation of the terminals are changed,


though functionally the same.

Added new functions.

Interchangeability in Installation
There is an interchangeability in installation, although depths (dimensions "A" and "B") are different.

Model Numbers
1
2
3
4
5
6
7
8
9
10
11
12
13
POWER
14
ON
15
16
OFF
17 18 19 20

A
B

AMC-T

mm (Inches)
A

Current

AMC-T-10

185
(7.28)

200
(7.87)

New

AMC-T-20

60
(2.36)

72
(2.83)

A
B

No.23

You might also like