Professional Documents
Culture Documents
Ground Floor
Ground Floor
Ground Floor
10
11
12
13
69 300
25 200
6 300
18 900
6 300
6 300
6 300
6 300
25 200
6 300
6 300
6 300
6 300
6 300
6 300
A
DOCTOR'S
LOUNGE
ER
LABORATORY
HEMS
OFFICE
NURSES
LOUNGE
X-RAY ROOM
LAN
ROOM
FEMALE
DOCTOR'S
QUARTER
11 000
MRI
SYSTEM
COMPONENT
ROOM
X-RAY ROOM
DARK ROOM
OFFICE
RAD TECHS
ROOM
MRI
CONTROL
ROOM
5 000
5 000
STO.
STUDENT
LOUNGE
MRI SCAN
ROOM
HALL
WAY
CORRIDOR
MALE
DOCTOR'S
QUARTER
X-RAY ROOM
X-RAY ROOM
X-RAY
CONSULTANT'S
ROOM
SUB-WAITING AREA
SUB-WAITING AREA
ER STOCK
ROOM
OBSERVATION ROOM
ER STOCK
ROOM
SUB-WAITING AREA
CORRIDOR
STRETCHERS/
WHEELCHAIR
HOLDING
AREA
C
FEMALE PUBLIC
TOILET
STO.
ELEVATOR
AND STAIR
LOBBY
FAMILY
MEDICINE
ISO
OFFICE
ENT / OPTHA
ULTRA
SOUND
ROOM
DN
PWD
TOILET
NURSE
STATION
ELEVATOR
ULTRA
SOUND
ROOM
MAMMOGRAPHY
ROOM
RECEPTION/
RECEIVING/
RELEASING
WAITING AREA
CORRIDOR
6 000
27 000
UP
PEDIA
HOMIS
OFFICE
11 000
LIGHTWELL
OPEN BELOW & ABOVE
27 000
6 000
EMERGENCY
AREA
CT SCAN
CONTROL
ROOM
SUB
WAITING
AREA
D
INFO.
RECEPTION
6 000
CORRIDOR
5 000
BATTERY
& UPS
ROOM
TRAUMA ROOM
ADMITTING
UNIT
UP
ORTHO
CLINIC
INFO./
RECEPTION
CASHIER'S
DN
2D ECHO
ECG
5 000
MAIN LOBBY
ELEVATOR
EMERGENCY ROOM
LOBBY
OB-GYNE
EXISTING
CT SCAN ROOM
NEW CT SCAN
ROOM
ELEVATOR
ELEVATOR
MEDICAL
SOCIAL
SERVICE
ADMITTING
OFFICE
TREATMENT
ECG
READING ROOM
PRIVATE
ADMITTING
SUB-WAITING
AREA
5 000
16 000
HALLWAY
ORTHO
OPD
CONTROL
ROOM
UTILITY AREA
RAMP UP
DN
STAIR UP
RAMP UP
GROUND FLOOR
FLOOR AREA =
VE
PD
AM
ER
L
HIC
6 300
6 450
6 800
3 000
3 075
3 225
6 300
6 300
6 300
6 300
6 300
6 300
69 300
2 650
SCHEME NO. 5
1
A
HEALTH FACILITY
DEVELOPMENT BUREAU
BAGUIO CITY
CORDILLERA ADMINISTRATIVE REGION
ARCHITECT OF RECORD
SCALE
1 000
RA 9266 SECTION 33
Drawings and specifications and
other contract documents duly signed,
stamped or sealed, as instruments of
service, are the intellectual property
and documents of the architect,
whether the object for which they are
made is executed or not. It shall be
unlawful for any person to duplicate
or make copies of said documents for
use in the repetition of and for other
projects or buildings, whether
executed partly or in whole, without
the written consent of the architect or
author of said documents.
1 : 100 METERS
PROJECT TITLE
5 000
SHEET CONTENTS
10m
10 000mm
RECOMMENDING APPROVAL
APPROVED
CONCURRED
END-USERS
INITIALS
SHEET NO.
PROPOSED REPAIR/RENOVATION OF
MARIA MINNIE O. ABAN
ARCHITECT IV, DOH-HFDB
LOCATION
ARIEL D. MAGBANUA
ARCHITECT IV, DOH-HFDB
A-2
FLAVIER BUILDING
GROUND FLOOR PLAN
DIRECTOR III
HEALTH FACILITY DEVELOPMENT BUREAU
: BongL
CHECKED BY : fal/moa/adm/RMP
DATE
: April 2015
REVISIONS
: June 2015