MTU ONSITE ENERGY

DIESEL GENERATOR SETS

contents

04

Rating definitions for diesel generator sets

combining our resources


to supply you with
dependable energy:
anytime. anywhere.
30

Prime Power 60 Hz/1800 rpm

08

Standby Power 50 Hz/1500 rpm

34

Grid Stability Power 50 Hz/1500 rpm

12

Standby Power 50 Hz/1500 rpm


only available in South America

36

Continuous Power 50 Hz/1500 rpm

38

Container/Enclosures 50 Hz/1500 rpm

14

Standby Power 60 Hz/1800 rpm

42

Enclosures 60 Hz/1800 rpm

18

Standby Power with overload


50 Hz/1500 rpm

46

Power Modules 50Hz/1500 rpm and


60 Hz/1800 rpm

20

Data Center Continuous Power


50 Hz/1500 rpm

48

Classifications for Data Centers


according to Uptime Institute

22

Data Center Continuous Power


60 Hz/1800 rpm

49

Footnotes

50

Website

51

Local Support

24

Prime Power 50 Hz/1500 rpm

28

Prime Power 50 Hz/1500 rpm


only available in South America

2 / // /

MTU Onsite Energy

MTU Onsite Energy is one of the core brands


of Rolls-Royce Power Systems AG, which is a
world-leading provider of high- and medium-speed
diesel and gas engines, complete drive systems,
distributed energy systems and fuel injection
systems for the most demanding environments.

Our product portfolio covers diesel generator sets up


to 3,250 kW, gas-powered cogeneration systems up
to 2,500 kW and gas turbines up to 50,000 kW,
furthermore medium-speed engines for land-based
energy solutions up to 9,300 kWe as part of the
Rolls-Royce Power Systems AG product portfolio.

MTU Onsite Energy offers complete power system


solutions: from mission critical to standby power to
continuous power, to combined heat and cooling.
We also provide a full line of service products to
help you get the most from your equipment.

More than 60 years of power generation systems


expertise and over a century of diesel engine
engineering experience have enabled us to provide
complete solutions all over the globe.
We continue to develop sustainable alternatives,
with systems that produce greener energy from
climate-neutral, regenerative fuels, such as
combined heat and power (CHP) plants.

Customers around the world trust us to provide


reliable power for a wide range of applications.

MTU Onsite Energy

/ // /

rating definitions for


diesel generator sets
Standby ratings

Prime ratings

Standby Power

Prime Power

Standby Power ratings apply to installations served by a reliable utility


source. The standby ratings are applicable to varying loads for the
duration of a power outage.
Typical applications: industrial and manufacturing plants, residential
areas, healthcare and hospitals, airports.

Prime Power ratings apply to installations where utility power is


unavailable or unreliable. At varying load, the number of generator set
operating hours is unlimited.
Typical applications: construction sites, remote areas. 10% overload is
available.

Standby Power with Overload (A)

Grid Stability Power (A)

Standby Power with Overload ratings apply to installations served by a


reliable utility source. The standby ratings are applicable to varying
loads for the duration of a power outage.
Typical applications: industrial and manufacturing plants, residential
areas, healthcare and hospitals, airports. 10% overload is available.

Grid Stability Power ratings apply to installations operating in support


of utility networks or grids (especially when renewable power sources
are used). At constant or varying load.
Typical applications: peak shaving, grid stability and capacity
programs. 10% overload is available.

Data Center Continuous Power


Data Center Continuous Power ratings apply to data center installations
where a reliable utility power is available and comply with Uptime
Institute* Tier III and IV requirements. At constant or varying load.
Typical applications: data centers. 10% overload is available.

* The Uptime Institute is a pioneer in creating and operating knowledge communities

Continuous ratings
Continuous Power (A)
Continuous Power ratings apply to installations where one or several
generator sets serve as utility. At constant or varying load, the number
of generator set operating hours is unlimited.
Typical applications: power stations. 10% overload is available.

for improving uptime effectiveness in data center facilities and information technology
organizations.

4 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

rating definitions
Overview
Standby ratings

Prime ratings

Standby Power
Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)
Uptime compliant

MTU Onsite Energy


variable
85%
no
500 h
Tier I & Tier II

ISO 8528-1 (ESP)


variable
70%
not specified
200 h
not specified

Prime Power
Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)
Uptime compliant

MTU Onsite Energy


variable
75%
yes
unlimited
Tier I & Tier II

ISO 8528-1 (PRP)


variable
70%
not specified
unlimited
not specified

Standby Power with Overload (A)


Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)
Uptime compliant

Data Center Continuous Power
Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)
Uptime compliant

MTU Onsite Energy


variable
85%
yes
500 h
Tier I & Tier II

ISO 8528-1 (ESP)


variable
70%
not specified
200 h
not specified

MTU Onsite Energy


continuous
100%
yes
1000 h; 500 h with 100% load
w/o interruption
Tier I & Tier II

ISO 8528-1 (LTP)


continuous
100%
not specified
500 h

MTU Onsite Energy


continuous
100%
yes
unlimited (B)
Tier III & Tier IV

ISO 8528-1
n.a.
n.a.
n.a.
n.a.
n.a.

Grid Stability Power (A)


Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)

Uptime compliant

Continuous rating
Continuous Power
Load
Load factor
10% overload (ICXN)
Max. operating hours (per year)
Uptime compliant

MTU Onsite Energy


constant
100%
yes
unlimited
Tier III & Tier IV

ISO 8528-1 (COP)


constant
100%
not specified
unlimited
not specified

6 / // /

MTU Onsite Energy

not specified

MTU Onsite Energy

/ // /

8 / // /

MTU Onsite Energy

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x

Cooling
variant (3)

Genset type

F32 AM 1A
F32 SM 1A
F32 TM 1A
NEF45 SM 1A
NEF45 SM 2A
NEF45 SM 5
4R924G60F
4R924G70F
4R924G80F
6R926G60F
6R926G70F
6R926G80F
6R926G90F
6R 1600 G70F
6R 1600 G80F
8V 1600 G70F
8V 1600 G80F
10V 1600 G70F
10V 1600 G80F
12V 1600 G70F
12V 1600 G80F
12V 2000 G65
12V 2000 G65TB
16V 2000 G25
16V 2000 G25TB
16V 2000 G65
16V 2000 G65TB
18V 2000 G65
18V 2000 G65TB
12V 2000 G76F
12V 2000 G86F
16V 2000 G76F
16V 2000 G86F
18V 2000 G76F

A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
W2A
A2A
W2A
A2A
W2A
A2A
W2A
A2A
A2A
A2A
A2A
A2A

MTU 4R0080 DS33


MTU 4R0080 DS45
MTU 4R0080 DS55
MTU 4R0113 DS63
MTU 4R0113 DS80
MTU 4R0113 DS94
MTU 4R0120 DS90
MTU 4R0120 DS110
MTU 4R0120 DS140
MTU 6R0120 DS175
MTU 6R0120 DS200
MTU 6R0120 DS235
MTU 6R0120 DS250
MTU 6R1600 DS300
MTU 6R1600 DS330
MTU 8V1600 DS400
MTU 8V1600 DS440
MTU 10V1600 DS500
MTU 10V1600 DS560
MTU 12V1600 DS660
MTU 12V1600 DS730
MTU 12V2000 DS850
MTU 12V2000 DS890
MTU 16V2000 DS1000
MTU 16V2000 DS1050
MTU 16V2000 DS1100
MTU 16V2000 DS1140
MTU 18V2000 DS1250
MTU 18V2000 DS1290
MTU 12V2000 DS825
MTU 12V2000 DS1000
MTU 16V2000 DS1100
MTU 16V2000 DS1250
MTU 18V2000 DS1400

Standby Power
50 Hz

Engine type

Container

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

Enclosure

x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier III & Tier IV

under FLEX program

NFPA 110
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier I & Tier II

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compl.

ISO 8528-5 - G3

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528-5 - G2

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x

CE / IEC

ISO 8528

x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage II

compliant
EPA Tier 2

Certifications

NEA Singapore for


ORDE

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

10500 V (3 Phase)

25
28
37
54
87
122
71
89
112
139
162
188
205
244
264
320
356
400
448
528
584
680
712
800
840
880
912
1000
1032
660
800
880
1000
1120

Emissions

10000 V (3 Phase)

415 V (3 Phase)

33(4)
45(4)
55(4)
63(4)
80(4)
94(4)
89
111
140
174
202
235
256
305(4)
330(4)
400(4)
445(4)
500(4)
560(4)
660(4)
730(4)
850
890
1000
1050
1100
1140
1250(5)
1290
825
1010
1100
1250
1400

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380V (3 Phase)

MTU 2000 DS-G06

MTU 2000 DS-G05

MTU 1600 DS

MTU 0120 DS

MTU 0080/0113 DS

Power
output (1)

German Grid Code

Standby Power 50 Hz/1500 rpm

x
x
x
x
x

MTU Onsite Energy

/ // /

Standby Power 50 Hz/1500 rpm

10 / // /

MTU Onsite Energy

Tier I & Tier II

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 4000 G23


12V 4000 G23
12V 4000 G63
16V 4000 G23
16V 4000 G63
20V 4000 G23
20V 4000 G63
20V 4000 G63L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1650


MTU 12V4000 DS1750
MTU 12V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 20V4000 DS2650
MTU 20V4000 DS3100
MTU 20V4000 DS3200

Standby Power
50 Hz

ISO 8528-5 - G3

x
x
x
x
x
x
x
x

Engine type

Container

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

Housing

Enclosure

German Grid Code

x
x
x
x
x
x
x
x

Tier III & Tier IV

NFPA 110

Uptime
compl.

CE / IEC

under FLEX program

Exhaust emission EU
97/68 EC Stage IIIA

Perform.
class (2)

ISO 8528

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

x
x
x
x
x
x
x
x

compliant
EPA Tier 2

x
x
x
x
x
x
x
x

Certifications

NEA Singapore for


ORDE

x
x
x
x
x
x
x
x

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x

10500 V (3 Phase)

1360
1440
1600
1840
1920
2160
2520
2600

Emissions

10000 V (3 Phase)

415 V (3 Phase)

1700
1800
2000
2300
2600
2700
3200
3400

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380V (3 Phase)

MTU 4000 DS

Power
output (1)

MTU Onsite Energy

/ // /

11

12 / // /

MTU Onsite Energy

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x

Standby Power 50 Hz
only in South America

Engine type

Cooling
variant (3)

Genset type

3029 TFG89
4045 TF280
4045 HF280
4R 924 G60F
4R 924 G70F
4R 924 G80F
6R 924 G60F
6R 924 G70F
6R 924 G80F
6R 1600 G70F
6R 1600 G80F
8V 1600 G70F
8V 1600 G780F
10V 1600 G70F
10V 1600 G80F
12V 1600 G70F
12V 1600 G80F
18V 2000 G76F

TC only
TC only
TC only
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A

MTU 3R0096 DS34


MTU 3R0096 DS44
MTU 3R0096 DS55
MTU 4R0120 DS90
MTU 4R0120 DS110
MTU 4R0120 DS140
MTU 6R0120 DS165
MTU 6R0120 DS200
MTU 6R0120 DS220
MTU 6R1600 DS300
MTU 6R1600 DS330
MTU 8V1600 DS400
MTU 8V1600 DS440
MTU 10V1600 DS500
MTU 10V1600 DS550
MTU 12V1600 DS650
MTU 12V1600 DS715
MTU 18V2000 DS1400

Container

Housing

Enclosure

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier III & Tier IV

German Grid Code

NFPA 110

ISO 8528

under FLEX program

CE compliant
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compl.

Tier I & Tier II

x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528-5 - G3

x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage II

compliant
EPA Tier 2

Certifications

NEA Singapore for


ORDE

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

10500 V (3 Phase)

x
x
x
x
x
x
x
x
x

10000 V (3 Phase)

x
x
x
x
x
x
x
x
x

Emissions

3300 V (3 Phase)

415 V (3 Phase)

24
32
40
71
89
111
134
160
178
240
264
320
352
400
440
520
572
1120

400 V (3 Phase)

30
40
50
89
111
139
167
200
222
300
330
400
440
500
550
650
715
1400

380 V (3 Phase)

kWe

220 V (3 Phase)

kVA

Available voltages

220 V (1 Phase)

MTU 2000 DS

MTU 1600 DS

MTU 0120 DS

MTU 0096 DS

Power
output (1)

ISO 8528-5 - G2

Standby Power 50 Hz/1500 rpm only available in South America

MTU Onsite Energy

/ // /

13

Standby Power 60 Hz/1800 rpm

14 / // /

MTU Onsite Energy

x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

3029TF289
4045TF280
4045TF280
4045TF280
4045HF280
4045HF285
4045HF285
4045HF285
6068HF285
6068HF485
6068HF485
4R 924 G60S
4R 924 G70S
4R 924 G80S
6R 926 G60S
6R 926 G70S
6R 926 G80S
6R 1600 G70S
6R 1600 G70S
6R 1600 G70S
6R 1600 G80S
8V 1600 G70S
8V 1600 G80S
10V 1600 G70S
10V 1600 G80S
12V 1600 G70S
12V 1600 G80S

TC only
TC only
TC only
TC only
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A

MTU 3R0096 DS30


MTU 4R0113 DS35
MTU 4R0113 DS40
MTU 4R0113 DS50
MTU 4R0113 DS60
MTU 4R0113 DS80
MTU 4R0113 DS100
MTU 4R0113 DS125
MTU 6R0113 DS150
MTU 6R0113 DS180
MTU 6R0113 DS200
MTU 4R0120 DS80
MTU 4R0120 DS100
MTU 4R0120 DS125
MTU 6R0120 DS150
MTU 6R0120 DS180
MTU 6R0120 DS200
MTU 6R1600 DS230
MTU 6R1600 DS250
MTU 6R1600 DS275
MTU 6R1600 DS300
MTU 8V1600 DS350
MTU 8V1600 DS400
MTU 10V1600 DS450
MTU 10V1600 DS500
MTU 12V1600 DS550
MTU 12V1600 DS600

Standby Power
60 Hz

Engine type

Container

Enclosure

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

Tier III & Tier IV

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compliant

Tier I & Tier II

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

IBC 2012

NFPA 110

x
x
x

UL2200

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

ISO 8528

Fuel consumption
optimized

Certifications

EPA Tier 2

EPA Tier 3

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 4i

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

13800 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

13200 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

12470 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

4160 V (3 Phase)

600 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

480 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

380 V (3 Phase)

38
44
50
63
75
100
125
156
188
225
250
90
113
139
169
204
225
288
313
344
375
438
500
563
625
688
750

Emissions

240 V (3 Phase)

30
35
40
50
60
80
100
125
150
180
200
72
90
111
135
163
180
230
250
275
300
350
400
450
500
550
600

240 V Re-connectable (1Ph.)

kVA

240 V Dedicated (1Phase)

kWe

Available voltages

208 V (3 Phase)

MTU 1600 DS

MTU 0120 DS

MTU 0096/0113 DS

Power
output (1)

MTU Onsite Energy

/ // /

15

Standby Power 60 Hz/1800 rpm

16 / // /

MTU Onsite Energy

x
x
x
x
x
x
x

x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 2000 G45


12V 2000 G85
12V 2000 G85
16V 2000 G45
16V 2000 G85
18V 2000 G85
18V 2000 G76S
12V 4000 G43
12V 4000 G83
16V 4000 G43
16V 4000 G83
16V 4000 G83L
20V 4000 G43
20V 4000 G83L
20V 4000 G83L
20V 4000 G83L

W2A
W2A
W2A
W2A
W2A
A2A
A2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V2000 DS650


MTU 12V2000 DS750
MTU 12V2000 DS800
MTU 16V2000 DS900
MTU 16V2000 DS1000
MTU 18V2000 DS1200
MTU 18V2000 DS1250
MTU 12V4000 DS1500
MTU 12V4000 DS1750
MTU 16V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 16V4000 DS2500
MTU 20V4000 DS2800
MTU 20V4000 DS3000
MTU 20V4000 DS3250

Standby Power
60 Hz

x
x
x
x
x
x

Engine type

Container

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Enclosure

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

Tier III & Tier IV

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compliant

Tier I & Tier II

IBC 2012

x
x
x
x
x
x
x

NFPA 110

x
x
x
x
x
x
x
x
x
x

UL2200

x
x
x
x
x
x
x
x
x
x

ISO 8528

x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x

Certifications

EPA Tier 2

x
x
x
x
x

EPA Tier 3

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 4i

4160 V (3 Phase)

x
x
x
x
x

13800 V (3 Phase)

600 V (3 Phase)

x
x
x
x
x

13200 V (3 Phase)

480 V (3 Phase)

x
x
x
x
x

12470 V (3 Phase)

380 V (3 Phase)

813
938
1000
1125
1250
1475
1563
1875
2188
2500
2813
3125
3125
3500
3750
4063

Emissions

240 V (3 Phase)

650
750
800
900
1000
1180
1250
1500
1750
2000
2250
2500
2500
2800
3000
3250

240 V Re-connectable (1Ph.)

kVA

240 V Dedicated (1Phase)

kWe

Available voltages

208 V (3 Phase)

MTU 4000 DS

MTU 2000 DS

Power
output (1)

MTU Onsite Energy

/ // /

17

18 / // /

MTU Onsite Energy

ISO 8528-5 - G3

Tier I & Tier II

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Engine type

Cooling
variant (3)

Genset type

12V 4000 G23


12V 4000 G23
12V 4000 G63
16V 4000 G23
16V 4000 G63
20V 4000 G23
20V 4000 G63
20V 4000 G63L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1650


MTU 12V4000 DS1750
MTU 12V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 20V4000 DS2650
MTU 20V4000 DS3100
MTU 20V4000 DS3200

Container

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

Housing

Enclosure

German Grid Code

x
x
x
x
x
x
x
x

Tier III & Tier IV

NFPA 110

Uptime
compl.

CE/IEC

x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528

x
x
x
x
x
x
x
x

under FLEX program

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

NEA Singapore for


ORDE

x
x
x
x
x
x
x
x

compliant
EPA Tier 2

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x

Certifications

10500 V (3 Phase)

1240
1320
1480
1680
1800
2080
2280
2480

Emissions

10000 V (3 Phase)

415 V (3 Phase)

1550
1650
1850
2100
2250
2600
2850
3100

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380 V (3 Phase)

MTU 4000 DS

Power
output (1)

MTU Onsite Energy

/ // /

19

Standby Power with


Overload 50 Hz

Standby Power with Overload 50 Hz/1500 rpm

Data Center Continuous Power 50 Hz/1500 rpm

20 / // /

MTU Onsite Energy

ISO 8528-5 - G3

Tier I & Tier II

Tier III & Tier IV

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 4000 G23


12V 4000 G23
12V 4000 G63
16V 4000 G23
16V 4000 G63
20V 4000 G23
20V 4000 G63
20V 4000 G63L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1650


MTU 12V4000 DS1750
MTU 12V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 20V4000 DS2650
MTU 20V4000 DS3100
MTU 20V4000 DS3200

MTU Onsite Energy

/ // /

21

Data Center Continuous


Power 50 Hz

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

Engine type

Container

German Grid Code

x
x
x
x
x
x
x
x

Housing

Enclosure

NFPA 110

Uptime
compl.

CE/IEC

x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528

x
x
x
x
x
x
x
x

under FLEX program

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

NEA Singapore for


ORDE

x
x
x
x
x
x
x
x

compliant
EPA Tier 2

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x

Certifications

10500 V (3 Phase)

1240
1320
1480
1680
1800
2080
2280
2480

Emissions

10000 V (3 Phase)

415 V (3 Phase)

1550
1650
1850
2100
2250
2600
2850
3100

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380 V (3 Phase)

MTU 4000 DS

Power
output (1)

Data Center Continuous Power 60 Hz/1800 rpm

22 / // /

MTU Onsite Energy

Tier I & Tier II

Tier III & Tier IV

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 4000 G43


12V 4000 G43
12V 4000 G83
16V 4000 G43
16V 4000 G83
20V 4000 G43
20V 4000 G83
20V 4000 G83L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1250


MTU 12V4000 DS1500
MTU 12V4000 DS1750
MTU 16V4000 DS2000
MTU 16V4000 DS2250
MTU 20V4000 DS2500
MTU 20V4000 DS2800
MTU 20V4000 DS3000

MTU Onsite Energy

Data Center Continuous


Power 60 Hz

IBC 2012

x
x
x
x
x
x
x
x

Engine type

Container

NFPA 110

x
x
x
x
x
x
x
x

Enclosure

UL2200

Housing

ISO 8528

x
x
x
x
x

Uptime
compliant

Fuel consumption
optimized

x
x
x
x
x

Certifications

EPA Tier 2

x
x
x
x
x

EPA Tier 3

x
x
x
x
x
x
x
x

EPA Tier 4i

x
x
x
x
x
x
x
x

13800 V (3 Phase)

x
x
x
x
x
x
x
x

13200 V (3 Phase)

4160 V (3 Phase)

x
x
x
x
x
x
x
x

12470 V (3 Phase)

600 V (3 Phase)

Emissions

480 V (3 Phase)

240 V (3 Phase)

1419
1750
2000
2281
2555
2844
3125
3500

208 V (3 Phase)

1135
1400
1600
1825
2045
2275
2500
2800

240 V Re-connectable (1Ph.)

kVA

240 V Dedicated (1Phase)

kWe

Available voltages

380 V (3 Phase)

MTU 4000 DS

Power
output (1)

/ // /

23

24 / // /

MTU Onsite Energy

x
x
x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

Cooling
variant (3)

Genset type

F32 AM 1A
F32 SM 1A
F32 TM 1A
NEF45 SM 1A
NEF45 SM 2A
NEF45 SM 5
4R924G10F
4R924G20F
4R924G30F
6R926G10F
6R926G20F
6R926G30F
6R926G40F
6R 1600 G10F
6R 1600 G20F
8V 1600 G10F
8V 1600 G20F
10V 1600 G10F
10V 1600 G20F
12V 1600 G10F
12V 1600 G20F
12V 2000 G65
12V 2000 G65TB
16V 2000 G25
16V 2000 G25TB
16V 2000 G65
16V 2000 G65TB
18V 2000 G65
18V 2000 G65TB
12V 2000 G16F
12V 2000 G26F
16V 2000 G16F
16V 2000 G26F
16V 2000 G36F
18V 2000 G26F

A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
W2A
A2A
W2A
A2A
W2A
A2A
W2A
A2A
A2A
A2A
A2A
A2A
A2A

MTU 4R0080 DS33


MTU 4R0080 DS45
MTU 4R0080 DS55
MTU 4R0113 DS63
MTU 4R0113 DS80
MTU 4R0113 DS94
MTU 4R0120 DS90
MTU 4R0120 DS110
MTU 4R0120 DS140
MTU 6R0120 DS175
MTU 6R0120 DS200
MTU 6R0120 DS235
MTU 6R0120 DS250
MTU 6R1600 DS300
MTU 6R1600 DS330
MTU 8V1600 DS400
MTU 8V1600 DS440
MTU 10V1600 DS500
MTU 10V1600 DS560
MTU 12V1600 DS660
MTU 12V1600 DS730
MTU 12V2000 DS850
MTU 12V2000 DS890
MTU 16V2000 DS1000
MTU 16V2000 DS1050
MTU 16V2000 DS1100
MTU 16V2000 DS1140
MTU 18V2000 DS1250
MTU 18V2000 DS1290
MTU 12V2000 DS825
MTU 12V2000 DS1000
MTU 16V2000 DS1000
MTU 16V2000 DS1100
MTU 16V2000 DS1250
MTU 18V2000 DS1400

x
x
x
x
x
x

MTU Onsite Energy

/ // /

25

Prime Power
50 Hz

x
x
x
x
x
x
x

x
x
x
x
x

Engine type

Container

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

Enclosure

x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier III & Tier IV

under FLEX program

Exhaust emission EU
97/68 EC Stage IIIA

NFPA 110
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier I & Tier II

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compl.

ISO 8528-5 - G3

x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

CE / IEC

x
x
x
x
x
x
x
x
x

ISO 8528

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

compliant
EPA Tier 2

Certifications

NEA Singapore for


ORDE

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

10500 V (3 Phase)

24
33
40
48
58
68
63
81
102
126
146
170
185
224
240
280
320
368
408
480
528
616
656
720
728
800
824
904
928
600
640
730
800
900
1000

Emissions

10000 V (3 Phase)

415 V (3 Phase)

30(4)
41(4)
50(4)
60(4)
73(4)
85(4)
79
101
127
158
182
213
231
280(4)
300(4)
350(4)
400(4)
460(4)
510(4)
600(4)
660(4)
770
820
900
910
1000
1030
1130 (5)
1160
750
800
910
1000
1135
1250

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380 V (3 Phase)

MTU 2000 DS-G06

MTU 2000 DS-G05

MTU 1600 DS

MTU 0120 DS

MTU 0080/0113 DS

Power
output (1)

German Grid Code

Prime Power 50 Hz/1500 rpm

Prime Power 50 Hz/1500 rpm

Tier I & Tier II

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 4000 G23


12V 4000 G23
12V 4000 G63
16V 4000 G23
16V 4000 G63
20V 4000 G23
20V 4000 G63
20V 4000 G63L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1650


MTU 12V4000 DS1750
MTU 12V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 20V4000 DS2650
MTU 20V4000 DS3100
MTU 20V4000 DS3200

Prime Power
50 Hz

ISO 8528-5 - G3

x
x
x
x
x
x
x
x

Engine type

Container

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

Housing

Enclosure

German Grid Code

x
x
x
x
x
x
x
x

Tier III & Tier IV

NFPA 110

Uptime
compl.

CE / IEC

x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528

x
x
x
x
x
x
x
x

under FLEX program

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

NEA Singapore for


ORDE

x
x
x
x
x
x
x
x

compliant
EPA Tier 2

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x

Certifications

10500 V (3 Phase)

1240
1320
1480
1680
1800
2080
2280
2480

Emissions

10000 V (3 Phase)

415 V (3 Phase)

1550
1650
1850
2100
2250
2600
2850
3100

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380 V (3 Phase)

MTU 4000 DS

Power
output (1)

26 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

27

28 / // /

MTU Onsite Energy

x
x
x
x
x
x
x
x

x
x
x
x
x
x

Engine type

Cooling
variant (3)

Genset type

3029 TFG89
4045 TF280
4045 HF280
4R 924 G10F
4R 924 G20F
4R 924 G30F
6R 926 G10F
6R 926 G20F
6R 926 G30F
6R 1600 G10F
6R 1600 G20F
8V 1600 G10F
8V 1600 G20F
10V 1600 G10F
10V 1600 G20F
12V 1600 G10F
12V 1600 G20F
18V 2000 G26F

TC only
TC only
TC only
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A

MTU 3R0096 DS34


MTU 3R0096 DS44
MTU 3R0096 DS55
MTU 4R0120 DS90
MTU 4R0120 DS110
MTU 4R0120 DS140
MTU 6R0120 DS165
MTU 6R0120 DS200
MTU 6R0120 DS220
MTU 6R1600 DS300
MTU 6R1600 DS330
MTU 8V1600 DS400
MTU 8V1600 DS440
MTU 10V1600 DS500
MTU 10V1600 DS550
MTU 12V1600 DS650
MTU 12V1600 DS715
MTU 18V2000 DS1400

Container

Enclosure

Tier III & Tier IV

German Grid Code

NFPA 110

CE compliant

ISO 8528

under FLEX program

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

MTU Onsite Energy

/ // /

29

Prime Power 50 Hz
only South America

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compl.

Tier I & Tier II

x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528-5 - G3

x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage II

compliant
EPA Tier 2

Certifications

NEA Singapore for


ORDE

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

10500 V (3 Phase)

x
x
x
x
x
x
x
x
x

10000 V (3 Phase)

x
x
x
x
x
x
x
x
x

Emissions

3300 V (3 Phase)

415 V (3 Phase)

27
35
44
64
80
100
120
144
160
220
240
292
320
360
400
472
520
1000

400 V (3 Phase)

34
44
55
80
100
125
150
180
200
275
300
365
400
450
500
590
650
1250

380 V (3 Phase)

kWe

220 V (3 Phase)

kVA

Available voltages

220 V (1 Phase)

MTU 2000 DS

MTU 1600 DS

MTU 0120 DS

MTU 0096 DS

Power
output (1)

ISO 8528-5 - G2

Prime Power 50 Hz/1500 rpm only available in South America

Prime Power 60 Hz/1800 rpm

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Engine type

Cooling
variant (3)

Genset type

3029TFG89
4045TF280
4045TF280
4045TF280
4045HF280
4045HF285
4045HF285
4045HF285
6068HF285
6068HF485
4R 924 G10S
4R 924 G20S
4R 924 G30S
6R 926 G10S
6R 926 G20S
6R 926 G30S

TC only
TC only
TC only
TC only
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A

MTU 3R0096 DS30


MTU 4R0113 DS35
MTU 4R0113 DS40
MTU 4R0113 DS50
MTU 4R0113 DS60
MTU 4R0113 DS80
MTU 4R0113 DS100
MTU 4R0113 DS125
MTU 6R0113 DS150
MTU 6R0113 DS180
MTU 4R0120 DS80
MTU 4R0120 DS100
MTU 4R0120 DS125
MTU 6R0120 DS150
MTU 6R0120 DS180
MTU 6R0120 DS200

Container

x
x
x
x
x
x
x
x
x
x

Enclosure

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

Tier III & Tier IV

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier I & Tier II

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compliant

Prime Power
60 Hz

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

IBC 2012

NFPA 110

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

UL2200

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

ISO 8528

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Certifications

EPA Tier 2

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 3

600 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 4i

480 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

13800 V (3 Phase)

380 V (3 Phase)

34
44
50
56
69
100
113
139
169
225
90
113
139
169
204
225

13200 V (3 Phase)

240 V (3 Phase)

27
35
40
45
55
80
90
111
135
180
72
90
111
135
163
180

12470 V (3 Phase)

kVA

4160 V (3 Phase)

kWe

208 V (3 Phase)

Emissions

240 V Re-connectable (1Ph.)

Available voltages
240 V Dedicated (1Phase)

MTU 0120 DS

MTU 0096/0113 DS

Power
output (1)

30 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

31

Prime Power 60 Hz/1800 rpm

32 / // /

MTU Onsite Energy

x
x
x
x
x

x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Engine type

Cooling
variant (3)

Genset type

6R 1600 G10S
6R 1600 G10S
6R 1600 G10S
6R 1600 G20S
8V 1600 G10S
8V 1600 G20S
10V 1600 G70S
10V 1600 G20S
12V 1600 G10S
12V 1600 G20S
12V 2000 G45
12V 2000 G85
12V 2000 G85
16V 2000 G45
16V 2000 G85
18V 2000 B76
12V 4000 G43
12V 4000 G43
12V 4000 G83
16V 4000 G43
16V 4000 G83
20V 4000 G43
20V 4000 G83
20V 4000 G83L

A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
A2A
W2A
W2A
W2A
W2A
A2A
A2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 6R1600 DS230


MTU 6R1600 DS250
MTU 6R1600 DS275
MTU 6R1600 DS300
MTU 8V1600 DS350
MTU 8V1600 DS400
MTU 10V1600 DS450
MTU 10V1600 DS500
MTU 12V1600 DS550
MTU 12V1600 DS600
MTU 12V2000 DS650
MTU 12V2000 DS750
MTU 12V2000 DS800
MTU 16V2000 DS900
MTU 16V2000 DS1000
MTU 18V2000 DS1250
MTU 12V4000 DS1250
MTU 12V4000 DS1500
MTU 12V4000 DS1750
MTU 16V4000 DS2000
MTU 16V4000 DS2250
MTU 20V4000 DS2500
MTU 20V4000 DS2800
MTU 20V4000 DS3000

Container

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Enclosure

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Tier III & Tier IV

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Housing

MTU Onsite Energy

Prime Power
60 Hz

x
x
x
x
x

Tier I & Tier II

x
x
x
x
x
x
x
x
x

IBC 2012

x
x
x
x
x
x
x
x

NFPA 110

x
x
x
x
x
x
x

UL2200

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Uptime
compliant

ISO 8528

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Certifications

EPA Tier 2

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 3

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

EPA Tier 4i

4160 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

13800 V (3 Phase)

600 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

13200 V (3 Phase)

480 V (3 Phase)

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

12470 V (3 Phase)

380 V (3 Phase)

263
288
313
344
406
456
500
563
625
688
769
850
906
1000
1125
1250
1406
1750
2000
2250
2556
2813
3125
3500

240 V (3 Phase)

210
230
250
275
325
365
400
450
500
550
615
680
725
800
900
1000
1125
1400
1600
1800
2045
2250
2500
2800

208 V (3 Phase)

kVA

Emissions

240 V Re-connectable (1Ph.)

kWe

Available voltages
240 V Dedicated (1Phase)

MTU 4000 DS

MTU 2000 DS

MTU 1600 DS

Power
output (1)

/ // /

33

Grid Stability Power 50 Hz/1500 rpm

Tier I & Tier II

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x

Cooling
variant (3)

Genset type

12V 4000 G23


12V 4000 G23
12V 4000 G63
16V 4000 G23
16V 4000 G63
20V 4000 G23
20V 4000 G63
20V 4000 G63L

W2A
W2A
W2A
W2A
W2A
W2A
W2A
W2A

MTU 12V4000 DS1650


MTU 12V4000 DS1750
MTU 12V4000 DS2000
MTU 16V4000 DS2250
MTU 16V4000 DS2500
MTU 20V4000 DS2650
MTU 20V4000 DS3100
MTU 20V4000 DS3200

Grid Stability Power


50 Hz

ISO 8528-5 - G3

x
x
x
x
x
x
x
x

Engine type

Container

ISO 8528-5 - G2

x
x
x
x
x
x
x
x

Housing

Enclosure

German Grid Code

x
x
x
x
x
x
x
x

Tier III & Tier IV

NFPA 110

Uptime
compl.

CE / IEC

x
x
x
x
x
x
x
x

Perform.
class (2)

ISO 8528

x
x
x
x
x
x
x
x

under FLEX program

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage IIIA

x
x
x
x
x
x
x
x

Exhaust emission EU
97/68 EC Stage II

NEA Singapore for


ORDE

x
x
x
x
x
x
x
x

compliant
EPA Tier 2

Exhaust emission
optimized acc. TA-Luft

x
x
x
x
x
x
x
x

Fuel consumption
optimized

x
x
x
x
x
x
x
x

11000 V (3 Phase)

x
x
x
x
x
x
x
x

Certifications

10500 V (3 Phase)

1240
1320
1480
1680
1800
2080
2280
2480

Emissions

10000 V (3 Phase)

415 V (3 Phase)

1550
1650
1850
2100
2250
2600
2850
3100

6600 V (3 Phase)

kWe

6300 V (3 Phase)

kVA

400 V (3 Phase)

Available voltages

380 V (3 Phase)

MTU 4000 DS

Power
output (1)

34 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

35

kWe
400 V (3 Phase)
415 V (3 Phase)

750
800
1000
600
640
800
x
x
x
x
x
x
x
x
x

36 / // /
MTU Onsite Energy

x
x
x
x
x
x
x

German Grid Code


ISO 8528-5 - G2
ISO 8528-5 - G3
Tier I & Tier II
Tier III & Tier IV

Perform.
class (2)
Uptime
compl.

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Container

NFPA 110

Certifications

Enclosure

CE / IEC

Emissions

ISO 8528

under FLEX program

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage IIIA

Exhaust emission EU
97/68 EC Stage II

compliant
EPA Tier 2

NEA Singapore for


ORDE

Available voltages
Exhaust emission
optimized acc. TA-Luft

Fuel consumption
optimized

11000 V (3 Phase)

10500 V (3 Phase)

10000 V (3 Phase)

6600 V (3 Phase)

Power
output (1)

6300 V (3 Phase)

kVA
380 V (3 Phase)

MTU 2000 DS

Housing

x
x
x
x
x

Engine type
Cooling
variant (3)
Genset type

12V 2000 B26F


16V 2000 B26F
18V 2000 B26F
A2A
A2A
A2A
MTU 12V2000 DS1000
MTU 16V2000 DS1250
MTU 18V2000 DS1400

MTU Onsite Energy

Continuous Power
50 Hz

Continuous Power 50 Hz/1500 rpm

/ // /

37

Container 50 Hz/1500 rpm


Noise level *

Noise level * with silencer


box and add. exhaust silencer

Fuel tank

dBA @ 1m

dBA @ 7m

dBA @ 1m

dBA @ 7m

dBA @ 1m

dBA @ 7m

Capacity (l)

CSS certification

Emissions

Height (mm)

(option)

Width (mm)

with silencer box

Length (mm)

without silencer box

20ft HC
20ft HC
20ft HC
20ft HC
20ft HC

6058
6058
6058
6058
6058

2438
2438
2438
2438
2438

2896
2896
2896
2896
2896

C/F
C/F
C/F
C/F
97

C/F
C/F
C/F
C/F
88

C/F
C/F
C/F
C/F
86

C/F
C/F
C/F
C/F
77

C/F
C/F
C/F
C/F
80

C/F
C/F
C/F
C/F
71

500
500
500
500
500

x
x
x
x
x

Genset type

MTU 12V2000 DS825


MTU 12V2000 DS1000
MTU 16V2000 DS1100
MTU 16V2000 DS1250
MTU 18V2000 DS1400

Contiainer
50 Hz

Noise level *

Size
MTU 2000 DS

Dimensions

* All levels in accordance with European Noise Directive (2000/14/EC)

38 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

39

Enclosures 50 Hz/1500 rpm


Fuel tank

Width (mm)

Height (mm)

dBA @ 7m

Capacity (l)

(option)

2100
2100
2300
2750
2750
2750
2750
2750
2750
C/F
C/F
C/F
C/F
4100
4100
4500
4500
4500
4500
5000
5000
C/F
C/F
7100
7100

957
957
1050
1100
1100
1100
1100
1100
1100
C/F
C/F
C/F
C/F
1600
1600
1800
1800
1800
1800
2100
2100
C/F
C/F
2190
2190

1349
1349
1458
1760
1760
1760
1760
1760
1760
C/F
C/F
C/F
C/F
2200
2200
2340
2340
2340
2340
2369
2369
C/F
C/F
2480
2480

61.7
60
59.3
61.2
61.3
61.5
C/F
C/F
C/F
C/F
C/F
C/F
C/F
63
63.2
62.8
62.8
62.8
62.8
72.2
74.5
C/F
C/F
C/F
C/F

100
100
130
288
288
288
288
288
288
C/F
C/F
C/F
C/F
597
597
740
740
740
740
950
950
900
900
900
900

Genset type

MTU 4R 0080 DS33


MTU 4R 0080 DS45
MTU 4R 0080 DS55
MTU 4R 0113 DS63
MTU 4R 0113 DS80
MTU 4R 0113 DS94
MTU 4R 0120 DS90
MTU 4R 0120 DS110
MTU 4R 0120 DS140
MTU 6R 0120 DS175
MTU 6R 0120 DS200
MTU 6R 0120 DS235
MTU 6R 0120 DS250
MTU 6R 1600 DS300
MTU 6R 1600 DS330
MTU 8V 1600 DS400
MTU 8V 1600 DS440
MTU 10V 1600 DS500
MTU 10V 1600 DS560
MTU 12V 1600 DS660
MTU 12V 1600 DS730
MTU 12V 2000 DS825
MTU 12V 2000 DS1000
MTU 16V 2000 DS1100
MTU 16V 2000 DS1250

Enclosures
50 Hz

Noise level *

Standard

Length (mm)
MTU 2000 DS

MTU 1600 DS

MTU 0120 DS

MTU 0080/0113 DS

Dimensions

* All levels in accordance with European Noise Directive (2000/14/EC)

40 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

41

Enclosures 60 Hz/1800 rpm

Level 3 (dBA @ 7m)

UL 2200

CSA

ISO 9001:2008

68.4
C/F
C/F
72
70.8
75.2
74.9
81.8
82.9
83
na
C/F
C/F
C/F
C/F
C/F
C/F
78.7
78.8
78.5
78.4
84.2
84.1
87.1
87.1
86.9
86.9

60.8
C/F
C/F
64.3
67.4
70.9
70.9
71.9
73.1
73.9
na
C/F
C/F
C/F
C/F
C/F
C/F
69.1
69.7
69.8
69.9
72.7
72.8
C/F
75.4
76.1
76.5

68.8
C/F
C/F
78.2
76.8
78.9
78.9
82.8
84.5
85.1
85.1
C/F
C/F
C/F
C/F
C/F
C/F
80.3
80.5
80.9
81
85.3
85.9
87.6
87.8
88.5
88.5

68.1
73.4
73.6
71.9
71.1
75.2
75.2
81.7
83
83
83
C/F
C/F
C/F
C/F
C/F
C/F
78.8
78.5
78.4
78.6
84.3
84.6
87.1
87.1
86.9
86.8

59.2
66.5
65.1
64.7
67.8
70.9
70.9
72
73.4
73.9
73.7
C/F
C/F
C/F
C/F
C/F
C/F
69.1
69.2
69.3
69.2
72.8
72.9
75.4
75.4
76.5
76.7

x
x
x
x
x
x
x
x
x
x
x
C/F
C/F
C/F
C/F
C/F
C/F
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
C/F
C/F
C/F
C/F
C/F
C/F
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
C/F
C/F
C/F
C/F
C/F
C/F
x
x
x
x
x
x
x
x
x
x

42 / // /

MTU Onsite Energy

x
x
x
x
x
x
C/F
C/F
C/F
C/F
C/F
C/F
x
x
x
x
x
x
x
x
x
x

MTU 4R 0060 DS30


MTU 4R 0113 DS35
MTU 4R 0113 DS40
MTU 4R 0113 DS50
MTU 4R 0113 DS60
MTU 4R 0113 DS80
MTU 4R 0113 DS100
MTU 4R 0113 DS125
MTU 6R 0113 DS150
MTU 6R 0113 DS180
MTU 6R 0113 DS200
MTU 4R 0120 DS80
MTU 4R 0120 DS100
MTU 4R 0120 DS125
MTU 6R 0120 DS150
MTU 6R 0120 DS180
MTU 6R 0120 DS200
MTU 6R 1600 DS230
MTU 6R 1600 DS250
MTU 6R 1600 DS275
MTU 6R 1600 DS300
MTU 8V 1600 DS350
MTU 8V 1600 DS400
MTU 10V 1600 DS450
MTU 10V 1600 DS500
MTU 12V 1600 DS550
MTU 12V 1600 DS600

Enclosures
60 Hz

Level 2 (dBA @ 7m)

68.2
C/F
C/F
77.6
76.7
78.9
79
82.5
84.3
85.1
na
C/F
C/F
C/F
C/F
C/F
C/F
79.9
80.3
80.5
80.9
85.5
85.5
C/F
87.6
88.5
88.3

IBC 2012/OSHPD

Level 1 (dBA @ 7m)

Genset type

Level 3 (dBA @ 7m)

Certifications

Level 2 (dBA @ 7m)

Standby Power

Level 1 (dBA @ 7m)


MTU 1600 DS

MTU 0120 DS

MTU 0060/0113 DS

Prime Power

MTU Onsite Energy

/ // /

43

Enclosures 60 Hz/1800 rpm

Level 3 (dBA @ 7m)

UL 2200

CSA

ISO 9001:2008

C/F
C/F
82.1
C/F
C/F
C/F
C/F
C/F
C/F

C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F
C/F

89
89
86.1
89.5
93
C/F
C/F
C/F
C/F

86.4
86.4
82
86.5
91.7
88
89.2
90.2
91.8

71.9
71.9
76
80.5
81.5
75.9
76.2
77.2
84

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x

MTU 12V 2000 DS650


MTU 12V 2000 DS750
MTU 12V 2000 DS800
MTU 12V 2000 DS900
MTU 12V 2000 DS1000
MTU 12V 4000 DS1250
MTU 12V 4000 DS1500
MTU 12V 4000 DS1750
MTU 16V 4000 DS2000

Enclosures
60 Hz

Level 2 (dBA @ 7m)

C/F
C/F
86
C/F
C/F
C/F
C/F
C/F
C/F

IBC 2012/OSHPD

Level 1 (dBA @ 7m)

Genset type

Level 3 (dBA @ 7m)

Certifications

Level 2 (dBA @ 7m)

Standby Power

Level 1 (dBA @ 7m)


MTU 4000 DS

MTU 2000 DS

Prime Power

44 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

45

x
x
x
x
x
x
x
x

x
x
x
x

Engine type

Cooling
variant (3)

Genset type

12V 1600 G20F


16V 4000 G63
16V 4000 G63
16V 4000 G63
12V 1600 G20S
16V 4000 G83
16V 4000 G83
16V 4000 G83

A2A
W2A
W2A
W2A
A2A
W2A
W2A
W2A

MTU 12V1600 DS550


MTU 16V4000 DS1955
MTU 16V4000 DS1955
MTU 16V4000 DS1955
MTU 12V1600 DS550
MTU 16V4000 DS1955
MTU 16V4000 DS1955
MTU 16V4000 DS1955

CSC certification

NFPA 110

50
50
50
50
60
60
60
60

ISO 8528

2896
2896
2896
2896
2896
2896
2896
2896

Standby Power

2438
2438
2438
2438
2438
2438
2438
2438

Prime Power

6058
12203
12203
12203
6058
12203
12203
12203

Certifications

Continuous Power

20ft HC
40ft HC
40ft HC
40ft HC
20ft HC
40ft HC
40ft HC
40ft HC

Applikation

x
x
x
x
x
x
x
x

Power Modules
50 Hz and 60 Hz

x
x
x

Frequency

Height (mm)

x
x
x
x

Width (mm)

x
x
x
x

Length (mm)

x
x
x
x

Size

520
1500
1720
1900
440
1760
1955
2160

Dimensions

EPA Tier 2

650
1875
2150
2375
550
2200
2443
2700

Fuel consumption
optimized

kWe

600 V

kVA

Emissions

480 V

Available
voltages

400 V

Power
output (1)

280 V

MTU 60 Hz

MTU 50 Hz

Power Modules 50 Hz/1500 rpm and 60 Hz/1800 rpm

46 / // /

MTU Onsite Energy

MTU Onsite Energy

/ // /

47

Classification for Data


Center Continuous Power
according to
Uptime Institute

Footnotes

Tier I

Only available for 50Hz markets

Tier I is composed of a single path for power and cooling distribution, without redundant components,
providing 99,67% availability.

Unlimited hours in data center application where a reliable grid/utility is present.

Tier II
Tier II is composed of a single path for power and cooling distribution, with redundant components,
providing 99,74% availability.

(1) P
 ower output based on 400V, fuel consumption opt. emission level and standard or optional generator.
For arrangements with other emissions, voltages and/or optional generators, ratings may vary.
Series 4000 without cooling package.

Tier III

(2) Ambient conditions and load application acc. to ISO 8528

Tier III is composed of multiple active power and cooling distribution paths, but only one active path
has redundant components and is concurrently maintainable, providing 99,98% availability.

(3) Cooling variants: A2A: air-to-air charge air cooling (TD); W2A: water-to-air charge air cooling (TB)

Tier IV

(5) Power available up to 25C intake air temperature / 100m site altitude above sea level

Tier IV is composed of multiple active power and cooling distribution paths, has redundant components
and is fault tolerant, providing 99,99% availability.

(6)

Application descriptions, e.g. load factor, applies to MTU powered equipment.

(4) Power available up to 32C intake air temperature / 400m site altitude above sea level

All levels in accordance with European Noise Directive (2000/14/EC)

C/F: Consult factory


Tier I

Tier II

Tier III

Tier IV

Delivery paths

One

One

Two Active

Redundant components

No

Yes

Simultaneously maintainable

No

No

One Active +
One Passive
Yes
(for active path)
Yes

Fault tolerance (single event)

No

No

No

Yes

Compartmentalisation

No

No

No

Yes

Availability

99,67%

99,74%

99,98%

99,99%

Suitable MTU Onsite Energy


application

Standby Power
Standby Power with Overload
Prime Power
Grid Stability Power

For complete definition see http://uptimeinstitute.com/

48 / // /

MTU Onsite Energy

Yes
(for two active paths)
Yes

Data Center Continuous Power


Continuous Power

Cooling variants:
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
Available power for diesel generator sets 50Hz / 1500 rmp
Standard:
// Site altitude above sea level: 400 m
// Intake air temperature:
40C
TA-Luft:
// Site altitude above sea level: 100 m
// Intake air temperature:
25C
NEA Singapore:
// Site altitude above sea level: 100 m
// Intake air temperature:
40C
Available power for diesel generator sets 60Hz / 1800 rmp
Standard:
// Site altitude above sea level: 400 m
// Intake air temperature:
25 C

MTU Onsite Energy

/ // /

49

Website.
Tools and Downloads.

Local support.
Worldwide.

From PS-SPEC sizing software to building information models (BIM) and


spec sheets for all our products, MTU Onsite Energy has the tools and
software to assist you with all aspects of your project design. Case studies
and technical articles are also available for download to reference existing
MTU Onsite Energy projects.

The reliability and performance of your MTU Onsite Energy systems are crucial for your success and
competitiveness. We are committed to your support. Our convenient global service network provides you
this assurance. Whenever and wherever you need expert support, MTU Onsite Energy specialists are
available. This continuous and long-term care ensures high availability, dependability and efficiency
throughout the lifecycle of your equipment. We ensure that you receive individualized support from our
extensive, global network of authorized MTU Onsite Energy service partners anywhere, anytime.

PS-SPEC Power System Sizing and Specification Software:


PS-SPEC Power System Sizing and Specification is a powerful, fully-featured
sizing and specification program for generator sets suitable for projects of
any size. PS-SPEC is a tool for consulting engineers, contractors, and other
professionals involved in the design, application load analysis or installation
of generator sets. PS-SPEC asks you to supply basic information about your
project requirements and then provides you with all the information you need
to select the appropriate equipment.
For detailed product information, please visit our website:
www.mtuonsiteenergy.com/products/diesel-generator-sets

50 / // /

MTU Onsite Energy