CENTRO DE SALUD ACOBAMBA

ING. JULIO CURI

Cantilever wall analysis


Input data
Project
Task
: CENTRO DE SALUD ACOBAMBA
Author : ING. JULIO CURI
Date : 16/03/2013
Material of structure
Unit weight = 24.00 kN/m3
Analysis of concrete structures carried out according to the standard ACI 31802.
Concrete : Concrete ACI
Compressive strength
Tensile strength
Elastic modulus
Longitudinal steel : A616/60
Tensile strength
Elastic modulus

fc = 21.00
MPa
fr = 2.85
MPa
Ec = 21689.22 MPa
fy = 413.69
MPa
Es = 199947.90 MPa

Geometry of structure
Coordinate Depth

No.

X [m]

Z [m]

0.00

0.00

0.00

3.15

1.10

3.15

1.10

3.50

-0.85

3.50

-0.85

3.15

-0.25

3.15

8
-0.25
0.00
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 1.47 m2.
Name : Geometry

Stage : 1

0.25

3.50 3.150.00:1
0.35

0.60

3.50
1.10
1.95

Basic soil parameters


No.

Name

Pattern

Gravelly silt (MG), consistency firm

ef

cef

su

[]

[kPa]

[kN/m3]

[kN/m3]

[]

24.40

5.00

18.00

8.00

24.00

Soil parameters to compute pressure at rest

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

No.

Name

Pattern

Gravelly silt (MG), consistency firm

Type

OCR

Kr

calculation

[]

[-]

[-]

[-]

cohesive

0.35

Soil parameters
Gravelly silt (MG), consistency firm
Unit weight :
Stress-state :

= 18.00
effective

kN/m3

Angle of internal friction :

ef = 24.40

Cohesion of soil :

cef = 5.00

kPa

Angle of friction struc.-soil :


Soil :

= 24.00
cohesive

Poisson's ratio :

Saturated unit weight :

sat = 18.00

= 0.35
kN/m3

Geological profile and assigned soils


No.

Layer
[m]

Assigned soil

20.00

Gravelly silt (MG), consistency firm

Gravelly silt (MG), consistency firm

Pattern

Terrain profile
Terrain behind construction has the slope 1: 1.60 (slope angle is 32.01 ).
Embankment height is 5.00 m, embankment length is 8.00 m.
Water influence
Ground water table is located below the structure.
Resistance on front face of the structure
Resistance on front face of the structure: passive
Soil on front face of the structure - Gravelly silt (MG), consistency firm
Soil thickness in front of structure h = 1.50 m
Angle of friction struc.-soil
= 20.00
Terrain in front of structure is flat.
Analysis settings
Active earth pressure calculation - Coulomb (CSN 730037)
Passive earth pressure calculation - Coulomb
Standard for concrete structures - ACI 31802
Analysis carried out according to classical theory (safety factor)
Safety factor for slip
= 1.50
Safety factor for overturning
= 1.50
Factor of safety for bearing capacity = 1.00
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1
Passive pressure on front face of the structure - partial results

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

1.00

0.00

24.40

5.00

18.00

-20.00

3.904

0.15

0.00

24.40

5.00

18.00

-20.00

3.904

0.00

89.87(24.40)

24.40

5.00

18.00

-20.00

2.569

0.35

0.00

24.40

5.00

18.00

-20.00

3.904

Kp

Comment

MODIFIED

Passive pressure distribution on front face of the structure


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

19.76

18.57

-6.76

1.00

18.00

0.00

90.02

84.59

-30.79

1.00

18.00

0.00

90.02

84.59

-30.79

1.15

20.70

0.00

100.56

94.50

-34.39

1.15

20.70

0.00

69.21

23.82

64.98

1.15

20.72

0.00

69.27

23.84

65.04

1.15

20.72

0.00

100.66

94.59

-34.43

1.50

27.00

0.00

125.15

117.61

-42.80

1
2
3
4

Active pressure behind the structure - partial results


Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

0.26

0.00

24.40

5.00

18.00

24.40

1.247

0.12

0.00

24.40

5.00

18.00

24.40

1.247

3.45

0.00

24.40

5.00

18.00

24.40

0.363

0.35

0.00

24.40

5.00

18.00

24.00

0.363

Ka

Comment

Active pressure distribution behind the structure (without surcharge)


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

-0.69

0.00

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.30

6.94

0.00

2.79

2.54

1.15

-0.30

6.94

0.00

2.79

2.54

1.15

3.15

69.08

0.00

52.53

47.83

21.70

3.15

69.08

0.00

52.53

47.99

21.36

3.50

75.38

0.00

54.81

50.08

22.30

1
2
3
4

Forces acting on construction


Fhor

App.Pt.

Fvert

App.Pt.

Design

[kN/m]

Z [m]

[kN/m]

X [m]

coefficient

Weight - wall

0.00

-1.11

35.28

0.84

1.000

FF resistance

-102.03

-0.57

-37.04

0.38

1.000

Weight - earth wedge

0.00

-2.10

69.18

1.42

1.000

Name

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

Active pressure

104.26

-1.33

47.15

1.95

1.000

Verification of complete wall


Check for overturning stability
Resisting moment
Mres = 205.54 kNm/m
Overturning moment Movr = 81.10 kNm/m
Safety factor = 2.53 > 1.50
Wall for overturning is SATISFACTORY
Check for slip
Resisting horizontal force
Active horizontal force

Hres = 61.72 kN/m


Hact = 2.23 kN/m

Safety factor = 27.73 > 1.50


Wall for slip is SATISFACTORY
Forces acting at the centre of footing bottom
Overall moment M = -12.73 kNm/m
Normal force
N = 114.57 kN/m
Shear force
Q = 2.23
kN/m
Overall check - WALL is SATISFACTORY
Name : Verification

Stage : 1; Analysis : 1

69.18
3.50

3.50
114.43

35.28

108.55

+x
1.95
+z

Bearing capacity of foundation soil


Forces acting at the centre of the footing bottom
Numb Moment
er
[kNm/m]

Norm. force

Shear Force

Eccentricity

Stress

[kN/m]

[kN/m]

[m]

[kPa]

114.57

2.23

0.00

58.75

-12.73

Bearing capacity of foundation soil check


Eccentricity verification
Max. eccentricity of normal force e
= 0.0
mm
Maximum allowable eccentricity
ealw = 643.5 mm
Eccentricity of the normal force is SATISFACTORY
Footing bottom bearing capacity verification
Max. stress at footing bottom
= 58.75 kPa
Bearing capacity of foundation soil Rd = 150.00 kPa
Safety factor = 2.55 > 1.00
Bearing capacity of foundation soil is SATISFACTORY
Overall verification - bearing capacity of found. soil is SATISFACTORY

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

Name : Bearing cap.

1.95

58.75

3.50

58.75

3.50

Stage : 1

Dimensioning No. 1
Passive pressure on front face of the structure - partial results
Layer Thickness

cd

d
[]

Kp

No.

[m]

[]

[]

[kPa]

[kN/m3]

1.00

0.00

24.40

5.00

18.00

-20.00

3.904

0.15

0.00

24.40

5.00

18.00

-20.00

3.904

Comment

Passive pressure distribution on front face of the structure


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

19.76

18.57

-6.76

1.00

18.00

0.00

90.02

84.59

-30.79

1.00

18.00

0.00

90.02

84.59

-30.79

1.15

20.68

0.00

100.47

94.42

-34.36

1
2

Pressure at rest behind the structure - partial results


Layer Thickness

cd

Kr

No.

[m]

[]

[]

[kPa]

[kN/m3]

3.15

0.00

24.40

5.00

18.00

Comment

0.836

Pressure at rest distribution behind the structure (without surcharge)


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

0.00

0.00

0.00

3.15

56.68

0.00

65.25

65.25

0.00

Forces acting on construction


Fhor

App.Pt.

Fvert

App.Pt.

Design

[kN/m]

Z [m]

[kN/m]

X [m]

coefficient

Weight - wall

0.00

-1.57

18.89

0.13

1.000

FF resistance

-64.89

-0.45

-23.62

0.00

1.000

Pressure at rest

102.72

-1.05

0.00

0.25

1.000

Name

Wall stem check


Reinforcement and dimensions of the cross-section
Bar number
=
5

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI
Number of bars
Reinforcement cover
Cross-section width
Cross-section depth
Reinforcement ratio
= 0.62 %
Reinforcement ratio
= 0.62 %
Ultimate moment
Mn = 78.84 kNm
Cross-section is SATISFACTORY.

=
6
=
50.0
mm
=
1.00
m
=
0.25
m
> 0.33 %
= min
< 1.63 %
= max
> 75.93 kNm = Mu

Name : Dimensioning

18.89

3.50

102.72

Stage : 1; Dimensioning : 1

3.50

69.06
1.95

Dimensioning No. 2
Passive pressure on front face of the structure - partial results
Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

1.00

0.00

24.40

5.00

18.00

-20.00

3.904

0.15

0.00

24.40

5.00

18.00

-20.00

3.904

Kp

Comment

Passive pressure distribution on front face of the structure


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

19.76

18.57

-6.76

1.00

18.00

0.00

90.02

84.59

-30.79

1.00

18.00

0.00

90.02

84.59

-30.79

1.15

20.68

0.00

100.47

94.42

-34.36

1
2

Pressure at rest behind the structure - partial results


Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

3.15

0.00

24.40

5.00

18.00

Kr

Comment

0.836

Pressure at rest distribution behind the structure (without surcharge)


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

0.00

0.00

0.00

3.15

56.68

0.00

65.25

65.25

0.00

Forces acting on construction


Name

Fhor

Fvert

App.Pt.

App.Pt.

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

Design

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

[kN/m]

Z [m]

[kN/m]

X [m]

coefficient

Weight - wall

0.00

-1.57

18.89

0.13

1.000

FF resistance

-64.89

-0.45

-23.62

0.00

1.000

Pressure at rest

102.72

-1.05

0.00

0.25

1.000

Wall check at the construction joint 3.15 m from the wall crest
Reinforcement and dimensions of the cross-section
Bar number
=
5
Number of bars
=
6
Reinforcement cover
=
50.0
mm
Cross-section width
=
1.00
m
Cross-section depth
=
0.25
m
Reinforcement ratio
= 0.62 %
> 0.33 %
= min
Reinforcement ratio
= 0.62 %
< 1.63 %
= max
Ultimate moment
Mn = 78.84 kNm > 75.93 kNm = Mu
Cross-section is SATISFACTORY.

Name : Dimensioning

3.50

18.89
3.15
102.72

Stage : 1; Dimensioning : 2

3.50

69.06
1.95

Dimensioning No. 3
Passive pressure on front face of the structure - partial results
Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

1.00

0.00

24.40

5.00

18.00

-20.00

3.904

0.15

0.00

24.40

5.00

18.00

-20.00

3.904

0.00

89.87(24.40)

24.40

5.00

18.00

-20.00

2.569

0.35

0.00

24.40

5.00

18.00

-20.00

3.904

Kp

Comment

MODIFIED

Passive pressure distribution on front face of the structure


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

19.76

18.57

-6.76

1.00

18.00

0.00

90.02

84.59

-30.79

1.00

18.00

0.00

90.02

84.59

-30.79

1.15

20.70

0.00

100.56

94.50

-34.39

1.15

20.70

0.00

69.21

23.82

64.98

1.15

20.72

0.00

69.27

23.84

65.04

1.15

20.72

0.00

100.66

94.59

-34.43

1
2
3
4

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

1.50

27.00

0.00

125.15

117.61

-42.80

Active pressure behind the structure - partial results


Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

0.26

0.00

24.40

5.00

18.00

24.40

1.247

0.12

0.00

24.40

5.00

18.00

24.40

1.247

3.45

0.00

24.40

5.00

18.00

24.40

0.363

0.35

0.00

24.40

5.00

18.00

24.00

0.363

Ka

Comment

Active pressure distribution behind the structure (without surcharge)


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

-0.69

0.00

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.30

6.94

0.00

2.79

2.54

1.15

-0.30

6.94

0.00

2.79

2.54

1.15

3.15

69.08

0.00

52.53

47.83

21.70

3.15

69.08

0.00

52.53

47.99

21.36

3.50

75.38

0.00

54.81

50.08

22.30

1
2
3
4

Forces acting on construction


Fhor

App.Pt.

Fvert

App.Pt.

Design

[kN/m]

Z [m]

[kN/m]

X [m]

coefficient

Weight - wall

0.00

-1.11

35.28

0.84

1.000

FF resistance

-102.03

-0.57

-37.04

0.38

1.000

Weight - earth wedge

0.00

-2.10

69.18

1.42

1.000

Active pressure

104.26

-1.33

47.15

1.95

1.000

Name

Front wall jump check


Stress at the footing bottom for wall jump dimensioning is assuemd as uniform.
Reinforcement and dimensions of the cross-section
Bar number
=
4
Number of bars
=
8
Reinforcement cover
=
75.0
mm
Cross-section width
=
1.00
m
Cross-section depth
=
0.35
m
Reinforcement ratio
= 0.38 %
> 0.33 %
= min
Reinforcement ratio
= 0.38 %
< 1.63 %
= max
Ultimate moment
Mn = 96.93 kNm > 9.64 kNm = Mu
Cross-section is SATISFACTORY.

Name : Dimensioning

Stage : 1; Dimensioning : 3

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

69.18
3.50

3.50
114.43

35.28

1.95

78.84

38.66

108.55

Dimensioning No. 4
Passive pressure on front face of the structure - partial results
Layer Thickness

cd

d
[]

Kp

No.

[m]

[]

[]

[kPa]

[kN/m3]

1.00

0.00

24.40

5.00

18.00

-20.00

3.904

0.15

0.00

24.40

5.00

18.00

-20.00

3.904

0.00

89.87(24.40)

24.40

5.00

18.00

-20.00

2.569

0.35

0.00

24.40

5.00

18.00

-20.00

3.904

Comment

MODIFIED

Passive pressure distribution on front face of the structure


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

0.00

0.00

0.00

19.76

18.57

-6.76

1.00

18.00

0.00

90.02

84.59

-30.79

1.00

18.00

0.00

90.02

84.59

-30.79

1.15

20.70

0.00

100.56

94.50

-34.39

1.15

20.70

0.00

69.21

23.82

64.98

1.15

20.72

0.00

69.27

23.84

65.04

1.15

20.72

0.00

100.66

94.59

-34.43

1.50

27.00

0.00

125.15

117.61

-42.80

1
2
3
4

Active pressure behind the structure - partial results


Layer Thickness

cd

No.

[m]

[]

[]

[kPa]

[kN/m3]

[]

0.26

0.00

24.40

5.00

18.00

24.40

1.247

0.12

0.00

24.40

5.00

18.00

24.40

1.247

3.45

0.00

24.40

5.00

18.00

24.40

0.363

0.35

0.00

24.40

5.00

18.00

24.00

0.363

Ka

Comment

Active pressure distribution behind the structure (without surcharge)


Layer Start [m]

Pressure

Hor. comp.

Vert. comp.

No.

End [m]

[kPa]

[kPa]

[kPa]

[kPa]

[kPa]

-0.69

0.00

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.43

4.71

0.00

0.00

0.00

0.00

-0.30

6.94

0.00

2.79

2.54

1.15

1
2

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

3
4

-0.30

6.94

0.00

2.79

2.54

1.15

3.15

69.08

0.00

52.53

47.83

21.70

3.15

69.08

0.00

52.53

47.99

21.36

3.50

75.38

0.00

54.81

50.08

22.30

Forces acting on construction


Fhor

App.Pt.

Fvert

App.Pt.

Design

[kN/m]

Z [m]

[kN/m]

X [m]

coefficient

Weight - wall

0.00

-0.18

9.24

1.40

1.000

Weight - earth wedge

0.00

-2.10

69.18

1.42

1.000

Active pressure

104.26

-1.33

47.15

1.95

1.000

Contact tractions

0.00

0.00

-74.26

1.43

1.000

Name

Back wall jump check


Reinforcement and dimensions of the cross-section
Bar number
=
4
Number of bars
=
8
Reinforcement cover
=
75.0
Cross-section width
=
1.00
Cross-section depth
=
0.35
Reinforcement ratio
= 0.38 %
> 0.33 %
Reinforcement ratio
= 0.38 %
< 1.63 %
Ultimate moment
Mn = 96.93 kNm > 1.25 kNm
Cross-section is SATISFACTORY.

mm
m
m
= min
= max
= Mu

Name : Dimensioning

Stage : 1; Dimensioning : 4

69.18
3.50

3.50
114.43
9.24
74.26
1.95

Slope stabilty analysis

Project
Analysis type : in effective parameters
Interface
Numbe
Interface location
r

Coordinates of interface points [m]


x

-10.00
-0.25
10.50

13.00
15.00
20.00

-0.85
0.00

13.00
15.00

-0.25
8.00

13.00
20.00

0.00
1.10

15.00
11.50

0.00
10.50

11.85
11.50

1.10

11.85

10

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

-10.00
-0.25

11.50
11.85

-0.85
-0.25

11.50
13.00

-0.85

11.50

1.10

11.50

-10.00

-5.00

0.00

-5.00

4
5

-0.85

11.85

10.50

-5.00

Soil parameters - effective stress state


Numbe
Name
r
1

Pattern

Gravelly silt (MG), consistency firm

ef

cef

[]

[kPa]

[kN/m3]

30.00

5.00

20.00

sat

[kN/m3]

[kN/m3]

[]

Soil parameters - uplift


Numbe
Name
r
1

Pattern

Gravelly silt (MG), consistency firm

20.00

Soil parameters
Gravelly silt (MG), consistency firm
Unit weight :

Angle of internal friction :

ef = 30.00

Cohesion of soil :

cef = 5.00

kPa

Saturated unit weight :

sat = 20.00

kN/m3

= 20.00

kN/m3

Rigid bodies
Numbe
Name
r
1

Sample

Rigid body

[kN/m3]
24.00

Assigning and surfaces


Numbe
Surface position
r

Coordinates of surface points [m]


x

Assigned
z

soil

0.00
1.10
10.50
0.00

11.85
11.50
20.00
15.00

1.10
10.50
8.00

11.85 Gravelly silt (MG),


11.50 consistency firm
20.00

1.10
0.00
-0.25
-0.25
-0.85

11.50
11.85
15.00
11.85
11.50

1.10
0.00
-0.25
-0.85

11.85
Rigid body
15.00
13.00
11.85

-0.85
-0.25
-0.85
-10.00

11.50
11.85
13.00
11.50

-0.85
-0.25
-10.00

11

11.85 Gravelly silt (MG),


13.00 consistency firm
13.00

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

0.00
10.50
-0.85
-10.00

-5.00
11.50
11.50
-5.00

10.50
1.10
-10.00

-5.00 Gravelly silt (MG),


11.50 consistency firm
11.50

0.00
-10.00
10.50

-5.00
-10.00
-5.00

-10.00
10.50

-5.00 Gravelly silt (MG),


-10.00 consistency firm

Water
Water type : No water
Tensile crack
Tensile crack not inputted.
Earthquake
Earthquake not included.
Analysis settings
Analysis settings : Standard
Analysis type :
Safety factor
Safety factor :
1.50

Results (Stage of construction 1)


Analysis 1
Circular slip surface
Slip surface parameters
Center :
Radius :

x=

-0.15 [m]

z=

20.41 [m]

R=

9.19 [m]

Angles :

1 =

-36.26 []

2 =

87.44 []

Analysis of the slip surface without optimization.


Slope stability verification (Bishop)
Sum of active forces :
Fa = 373.92 kN/m
Sum of passive forces : Fp = 686.93 kN/m
Sliding moment :
Resisting moment :

Ma = 3436.32 kNm/m
Mp = 6312.88 kNm/m

Factor of safety = 1.84 > 1.50


Slope stability ACCEPTABLE
Name : Analysis

Stage - analysis : 1 - 1

12

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

13

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

CENTRO DE SALUD ACOBAMBA


ING. JULIO CURI

14

[Geo 5 - Cantilever wall (demoversion) | version 5.9.14.0 | Copyright (c) FINE Ltd. 2009 | www.finesoftware.eu]

You might also like