bp220 pd957

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

COMAPARATIVE ANALYSIS OF FEATURES B/N BP 220 & PD 957

FEATURES

BP 220

Project Size
Range

Up to 2.5 Ha

Land allocation
Saleable
Common Area
Locational
Considerations

No fixed Ratio

Utilities/Facilities
a. Water

Above
2.5 to
15.0 Has
No fixed
Ratio

Above
15.0 to
30.0 Has.
No fixed
Ratio

Above 30.0
Has

MODEL A
None

PD 957
MODEL B
None

MODEL C
None

No fixed Ratio

1. The Actual setting of the project size shall determine the


type and degree of development to be required regardless
of political boundaries. With respect to this, the degree on
the level of development shall be defined as follows;
a. Underdeveloped Area: characterized by the
absence of utility system or networks, especially
water supply, roads and power.
b. Developed Area: characterized by the presence of
utility system or networks, especially water supply,
roads and power.
a. Underdeveloped Areas
1. Water supply must at least be 43 liters/capita/day
2. Provision of communal wells
b. Developed Areas
1. water supply must at least be 75 liters/capita/day
2. Public Water Supply system or independent water supply
system

70%
30%
1. All cities/
municipalities
regardless of
class

70%
30%
1. 2nd class
municipalities and
below.
2. As variance in
cities and 1st class
municipalities

70%
30%
1. 3rd class
municipalities
and below
2. As variance in
2nd class
municipalities or
in urban land
reform zones or
blighted areas.

Public Water
System or
centralized
water supply
system.

Public Water
System or
centralized water
supply system.

Public Water
system or
communal/
Individual well.

Maximum Block
Length
a. bounded by
streets on both
ends

400 m. block length.


Exceeding 250 m., not beyond 400m shall be provided by a alley
at midlength.

Water supply
Water supply
Water supply
must be at least
must be at least
must be at least 75
43
75
liters/capita/day
liters/capita/day
liters/capita/day
400 block length.
Exceeding 250 m., but not beyond 400 m. shall be
provided by a alley at midlenght.

b. Bounded by

150.00 m.

Not allowed

150.00 m

150.00 m

150.00

Not allowed

Not allowed

streets on both
ends
c. Bounded on
both ends
pathwalks
Minimum Lot
Frontages
a. Single Detached
b. Single Attached
c. Row House
d. Corner Lot
e. Interior and thru
lot
f.Irregular

Required Areas for


Community
Facilities ( % of
Gross Area)

Required Areas for


Parks/Playgrounds
(% of Gross Area)

Sewage Disposal

Drainage

Power/Electricity

m
100.00 m

150.00 m

100.00 m

100.00
m

Not allowed

Not allowed

Not allowed

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

8.00 m
6.00 m
3.50 m

3.50 m

3.50 m

3.50 m

3.50 m

6.00 m

4.00 m

4.00 m

a. 1% for 150 and below lots/ or living units


per hectare.
b. 1.5% for 151 to 225 lots/ or living units
per hectare.
c. 2.0% for 226 and above the lots living
units per
hectare.
a. 3.5% for 150 and below lots/ or living
units per hectare.
b. 7.0% for 151 to 225 lots/ or living units
per hectare.
c. 9.0% for 226 and above lots or living units
per hectare.
a. The minimum requirement for sewage
disposal shall be
the use of septic a tank.
b. Communal septic tank may be allowed.
a. open canal on each side of the circulation
network
b. Catchments area for drainage discharge
shall be
provided to prevent flooding.
Optional, however, developer shall provide
sufficient land area for easement of power
facilities.

Variable

Variable

Variable

a. 3.5% for 20 and below lots/ or living units per hectare.


b. 7.0% for 21 to 65 lots/ or living units per hectare.
c. 9.0% for 66 to 100 above lots or living units per hectare.

Individual Septic Tanks,


If possible,
Sewer system
Underground draining into
public drainage system

Required, primary and


alternative source of power.

Individual Septic
Tanks,
If possible,
Sewer system
Underground
draining into
public drainage
system

Individual Septic
Tanks

Required,
primary and
alternative

Optional

Open Canal

Garbage Disposal
Street
Specifications
1.Row
a. Major
b. Minor
1. Collector
2. Service
c. Alley
d.Pathwalk/
Footpath
e. Sidewalk
2. Maximum
Length/Dead End
a. Major
b. Minor
1. Collector
2. Service

Shall be undertaken by the local government or


in the absence thereof, the individual lot owner.
3.00 m
2.00 m

8.00 m
8.00 m
3.00 m
2.00 m

10.00 m
10.00 m
8.00 m
6.50 m
3.00 m
2.00 m

12.50 m
12.50 m
10.00 m
8.00 m
3.00 m
2.00 m

15.00 m
15.00 m
12.50 m
10.00 m
4.00 m

Variable according to
road class

Variable

Dead not
allowed

Dead not
allowed

Dead end not allowed

Dead end not


allowed

Dead end not


allowed

Dead end not


allowed

Terminus
connecting to
street
-

120.00 m. (dead-end ) provide for turn-around


If 50.00 m or less, turn-around space not
required.

c. Alley

150.00 m both ends connecting to a minor road;


75.00 m dead end

d. Pathwalks

100.00 m both ends connecting to an alley;


50.00 m dead end
Undev.Dev.
Undev.
Dev.
Undev.
Macadam
Asphalt
Macadam
Asphalt Macadam

3. Pavement
a. Major
b. Minor

1.Collector
2. Service

source of power.
Undertaken by the subdivision in conjunction with the local government.

Aggre-Macadam AggreMacadam Aggregates


gates
gates

Dead end not allowed, space


for turn around must be
provided
Dev.
Asphalt

Undev.
Dev.
Macadam Asphalt
Aggregates

Concrete/
Asphalt
Macadam Concrete/
Asphalt
Concrete/
Asphalt
Concrete/

10.00 m
10.00 m
8.00 m
4.00 m
4.00 m

Dead
not
allowed

8.00 m
8.00 m
6.50 m
4.00 m
4.00 m

Asphalt

Macadam

Asphalt

4 thk
gravel on
compacted
earth

Asphalt
3. Alley

Aggre-Aggregates gates

AggreAggregates
gates

Aggregates

Aggregates

Aggregates

Aggregates

c. Pathwalks

Aggre-Aggregates gates

AggreAggregates
gates

Aggre-

Aggregates

Aggregates

Aggregates

d. Sidewalk

Lot Sizes Minimum


Area
a. Detached
b. SemiDetached
c.Cluster/Rowhouse

72.00
m2
54.00
m2
Corner
Lot
36.00
m2

72.00
m2
54.00
m2
Corner
Lot
36.00
m2

BUILDING DESIGN STANDARDS

72.00
m2
54.00
m2
Corner
Lot
36.00
m2

Asphalt

Pre-fab
slabs
CHB/
Asphalt
Pre-fab
slabs
CHB/
Asphalt

72.00 m2

100.00 m2

100.00 m2

100.00 m2

54.00 m2Corner Lot

100.00 m2

100.00 m2

100.00 m2

36.00 m2

50.00 m2

50.00 m2

50.00 m2

Pre-fab
slabs
CHB/Asphalt
Pre-fab
slabs
CHB/Asphalt

BP 220
Single Family Dwellings
Multi-Family Dwellings

PD 1096 National Building Code

1. Minimum Floor area Requirement

20.00 m2

36.00 m2Living Unit

2. Ceiling Height- w/out ceilings


Minimum Head Clearance)
3. Mezzanine Floors

2.0 m

2.0 m

a. Rooms for human habitations


6.00 m2 : 2.00 m least dimension.
b. Kitchen 3.00 m2 : 1.5 m least
dimension.
c. Toilet & bath 1.20 m2 : .90
least dimension.
2.40 m

a. 1.80 m above and below


it
b. Not cover 50% of the

a. 1.80 m above and


below it
b. Not cover 50% of

1.80 m above and below it

4 thk
gravel on
compacted
earth
Gravel

Gravel

4. Openings
A. Doors

1. Clear Width
a. Main door
b. service/bedroom
c. Bathroom door
2. Clear Heights
a. Main door
b. Service/Bedroom
c. Bathroom door
B. Windows

Bathroom window
5. Corridors and Exterior exit, Balconies

a. Minimum Width
b. Projections

c. Dead Ends

floor area below


At least 1 entrance and 1
exit shall be provided for
occupants not more than
10, 2 entrances/exits for
occupants greater than 10

the floor area below


The requirements of
the building or portion
thereof shall be
determined by the
occupant load which
gives the largest
number of persons
(occupant load = no.
of living units x 6)

0.80 m
0.70 m
0.60 m

0.80 m
0.70 m
0.60 m

0.90 m (Chapter 12)


0.90 m (Chapter 12)
0.90 m (Chapter 12)

2.00 m
2.00 m
1.80 m
10% of the floor area of the
room, provided that such
opening shall not be less
than 1 sq. m.

2.00 m
2.00 m
1.80 m
10% of the floor area
of the room, provided
that such opening
shall not be less than
1 sq. m.
1/20 of the floor area,
provided that is not
less than 240 sq. mm.
Shall apply to every
corridor and exterior
exit balcony serving as
a required exit for an
occupant load > 50.
1.20 m
Shall be unobstructed.
Door in any position
shall not reduce the
require width of
corridor by more than
one half ( of corridor
width)
Are permitted when
the dead end does not
exceed 12.00 m. in

2.00 m
2.00 m
1.80 m
10% of the floor area of the
room, provided that such opening
shall not be less than 1 sq. m.

1/20 of the floor area,


provided that is not less
than 240 sq. mm.

Minimum of 1 entrance and


another 1 exit (Chapter 7, sec
709; ii) Minimum requirements
for group A dwellings.
More than 185m2/18m least
dimension.

1/20 of the floor area,


provided that is not less than 240
sq. mm.
Shall apply to every corridor and
exterior exit balcony serving as a
required exit for an occupant load
> 10.
1.10 m
Shall be unobstructed, handrails
and doors when fully opened
shall not reduce the required
width of corridor by more than
200 mm.
Are permitted when the dead
ends does not exceed 6.00 m. in
length.

length.
6. Stairways
a. Minimum Clear Width

0.60 m

0.60 m

b. Handrails

Shall have one rail on one


side, provided there is a
guard or wall on the other
side.

c. Rise and Run

Maximum rise 250 mm.


Minimum run 200 mm.
Dimension shall be
measured in the direction of
travel equal to the width of
the staircase.
Maximum vertical distance
3.60 m.
2.00 m.

Stairways less than


3.00 m wide shall
have at least one
handrail, provided
there is a guard or
wall on the other
side.
200 mm
250 mm
Dimension shall be
measured in the
direction of travel
equal to the width of
the staircase.
Maximum vertical
distance 3.60 m.
2.00 m.

50% of lot
20% of lot
10% of lot

50% of lot
20% of lot
10% of lot

50% of lot
20% of lot
10% of lot

5% of lot
1.50 m

5% of lot
1.50 m

5% of lot
1.50 m (Art 704, NBC)

6.00 m
2.00 m

6.00 m
2.00 m

n.a.
n.a.

10.00 m
6.00 m

d. Landining

e. Distance between Landings


f. Minimum Headroom Clearance
7. Plot Planning
a. Open Space Requirements
1. Interior lot
2. Inside lot
3. Corner lot
4. Open lot
8. Minimum Horizontal Clearance
between 2 roof eaves
a. Taller Buildings 3 to 4 stories
Minimum Horizontal clearance between
eaves.
b. Taller Buildings more than 4 stories
Minimum Horizontal Clearance
between eaves
9. Abutments

Permitted on all sides provided that:


a. A firewall extending at least 0.30 m from the

Occupant Load Minimum Width


>50 = 1.10m.
<50 = 1.10m. *exclusive of
railings
<10 = 0.75m.
Shall not reduce required width
by 100 mm

200 mm
250 mm
Dimension shall be measured in
the direction of travel equal to the
width of the staircase.
Maximum vertical distance 3.60
m.
2.00 m.

Permitted for r-2 and r3 on the


front and rear property lines,

roofline is constructed.
b. There shall be no opening on the party
firewall.
c. The firewall shall have a minimum of one
hour fire resistance.
d. The open space requirements are complied
with

10. Parking

a. Open Spaces such as


streets/easement of seashore,
rivers, esteros
b. Setback requirements
No. of Storey
1-2
3
4
5
6
7
8
9
10
11
12
11. Sizes and dimensions of Courts and
Yards
a. Minimum Horizontal dimension
b. Minimum width
1. Single Family Dwellings
2. Multi-Family Dwellings(Cluster
Living)

1 slot in 20 Living
Units
PD 1096

provided that the following


requirements are complied with:
a. Open space are complied
with as prescribed in
Table I (BP 220)
b. Window opening as
prescribed in Section 7
c. Firewall with the minimum
of 1 hour rating
constructed with a
minimum height
clearance of 1.00 m
above roof.
Low income single detached
living units in housing project
areas with individual lots not
more than 100.
PD 1096
Minimum Setback Required per
storey
2.00 m
2.30 m
2.60 m
2.90 m
3.20 m
3.50 m
3.80 m
4.10 m
4.40 m
4.70 m
5.00 m

n.a
n.a
n.a
n.a
n.a
n.a
n.a
n.a
n.a
n.a
n.a

2.00 m

2.00 m

2.00 m

2.00 m
1.50 m

2.00 m
1.50 m

2.00 m
1.50 m

12. Distance Between buildings


Taller building has not more than 2
stories

4.00 m

4.00 m

Buildings on the same property


and court walls shall be assumed
to have a property line between
them. (Chapter 7).
Common Parking Slot is oneslot/ten living units.

You might also like