Vertical Turbine Pumps Engineering Data: Effective April 1, 2003

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Vertical Turbine Pumps

Engineering Data
Effective April 1, 2003

Lineshaft Turbine Bowl Assembly Data___________________________________________________________


Model
and
Size
5C
5T
5WA
6C
6DH
6RA
7C
7RA
7T
7WA
8DH
8I
8RA
8RJ
9B
9RA
9RC
9T
9WA
10DH
10L
10RA
10RJ
10WA
11C
11RA
11WA
12C
12DH
12FR
12WA
12RJ
13C
13RA
14DH
14F
14H
14RH

Bowl Assembly Length


L0
1.81
1.81
1.81
2.50
2.06
2.06
2.38
2.38
2.38
2.38
2.38
2.38
2.38
2.38
3.00
2.38
3.00
3.00
3.00
2.94
2.94
2.94
2.94
3.00
3.50
4.13
3.50
4.13
4.13
4.13
4.13
4.13
4.13
3.13
3.13
6.50
6.50
6.50

L1
N/A
N/A
N/A
N/A
N/A
N/A
0.88
1.19
0.88
0.88
0.88
0.88
0.88
0.88
1.25
1.19
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.00
2.13
1.00
2.13
2.13
N/A
2.13
2.13
N/A
3.00
3.00
N/A
N/A
N/A

L2
4.75
4.75
4.75
4.75
5.13
5.13
4.38
4.38
4.38
4.38
4.38
4.38
4.38
4.38
5.25
4.38
5.25
5.25
5.25
5.19
7.63
5.19
5.19
5.25
5.75
5.75
5.75
5.75
5.75
8.25
5.75
5.75
5.75
9.00
9.00
13.50
13.50
13.50

L3
4.63
4.81
4.00
5.13
5.50
3.75
6.38
4.50
7.09
5.50
7.38
6.38
5.00
6.50
7.63
5.50
8.50
9.25
6.63
9.25
8.75
6.63
8.40
7.63
9.88
8.00
8.75
11.00
11.25
12.50
9.00
9.60
11.13
9.50
13.25
13.63
13.63
13.63

L4
5.00
5.00
5.00
5.00
5.38
N/A
5.88
N/A
5.88
6.13
6.00
6.88
N/A
6.25
9.19
N/A
9.25
9.25
9.25
8.38
9.38
N/A
9.69
9.19
10.13
N/A
10.13
10.38
9.50
9.13
9.75
10.38
10.13
N/A
10.75
10.88
10.88
10.88

L5
N/A
N/A
3.00
3.94
5.38
3.00
3.13
3.75
3.13
3.25
6.00
3.75
3.19
3.50
5.06
3.25
5.00
5.00
5.00
5.75
9.38
3.94
5.88
5.06
5.63
4.63
5.63
6.88
8.00
8.00
6.88
6.88
5.56
7.00
10.75
8.00
10.88
8.00

L6
18.50
18.63
17.88
19.88
21.06
19.19
22.00
20.38
22.81
21.25
24.75
23.00
20.63
22.53
27.13
21.88
28.00
28.75
26.13
30.63
30.81
25.06
28.13
27.13
30.25
28.63
29.38
32.63
33.25
33.75
29.88
30.81
32.00
31.38
37.00
40.25
40.25
40.25

L7
N/A
N/A
26.81
28.13
30.13
28.25
30.00
28.38
30.81
29.25
32.75
31.00
28.63
30.53
35.38
29.88
36.25
37.00
34.38
38.88
41.50
33.31
36.44
35.38
38.50
36.25
37.63
40.25
40.88
43.88
37.50
38.50
39.63
43.25
49.88
53.25
53.25
53.25

O
0.63
0.63
0.63
0.63
1.75
N/A
1.00
N/A
1.00
1.00
2.88
0.75
N/A
1.00
1.00
N/A
0.88
0.88
0.88
4.44
4.00
N/A
0.94
1.00
0.88
N/A
0.88
0.88
2.50
2.88
1.00
0.88
1.00
N/A
5.88
3.75
3.75
3.75

O1
N/A
N/A
2.63
1.69
1.75
4.00
3.75
3.38
3.75
3.75
2.88
4.13
3.69
3.75
5.13
4.13
5.13
5.13
5.13
7.06
4.00
5.69
4.75
5.13
5.38
6.00
5.38
4.38
4.00
4.00
3.88
4.38
5.56
5.50
5.88
6.63
3.75
6.63

Basket
Floor
Bowl Bowl
Strainer
Clearance O.D. Shaft
(Optional)
Dia.
E
F
X
D
N/A
N/A
2.00
5.20
1.00
N/A
N/A
2.00
5.20
1.00
5.40 6.70
6.00
5.20
1.00
5.40 6.70
2.00
5.88
1.00
5.40 6.70
4.63
5.44
1.00
5.40 6.70
6.00
5.50
1.00
5.30 7.50
4.50
7.13
1.19
5.40 6.70
5.38
7.50
1.00
5.30 7.50
5.50
7.13
1.19
5.63 7.63
8.00
7.13
1.19
8.25 8.38
9.00
7.50
1.19
5.30 7.50
6.50
7.50
1.19
5.63 7.63
5.88
7.50
1.19
5.30 7.50
6.50
7.50
1.19
6.70 10.62
9.00
9.50
1.50
5.30 7.50
7.25
7.50
1.19
6.70 10.63
7.13
9.25
1.50
6.70 10.63
7.13
9.25
1.50
6.70 10.63
7.13
9.25
1.50
11.38 13.75
14.00
9.50
1.69
6.76 10.63
6.50
9.50
1.69
7.25 8.50
7.88
9.50
1.50
6.70 10.63
7.50
9.50
1.50
6.70 10.63
9.00
9.50
1.50
6.38 12.13
8.00
11.00
1.69
6.70 10.63
8.13
11.60
1.69
6.38 12.13
9.50
11.00
1.69
6.38 12.13
8.00
11.75
1.69
6.38 12.13
13.00
11.60
1.94
6.38 12.13
13.00
11.75
1.94
6.38 12.13
8.00
11.60
1.69
6.38 12.13
8.00
11.60
1.69
6.38 12.13
8.00
12.38
1.94
7.75 15.50
7.63
13.38
1.94
12.88 14.50
18.00
13.25
2.19
14.50 15.38
15.00
14.00
2.19
14.50 15.38
12.00
14.00
2.19
14.50 15.38
15.00
14.00
2.19

(All dimensions are in inches and weights in lbs.)

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE


Continue on next page

Available
Lineshaft
Size

Col.
Pipe
Size

1.00
1.00
1.00
1.00
1.00
1.00
1.00-1.19
1.00
1.00-1.19
1.00-1.19
1.00-1.19
1.00-1.19
1.00-1.19
1.00-1.19
1.00-1.50
1.00-1.19
1.00-1.50
1.00-1.50
1.00-1.50
1.00-1.69
1.00-1.69
1.00-1.50
1.00-1.50
1.00-1.50
1.00-1.69
1.00-1.69
1.00-1.69
1.00-1.69
1.00-1.94
1.00-1.94
1.00-1.69
1.00-1.69
1.00-1.94
1.00-1.94
1.19-2.19
1.19-2.19
1.19-2.19
1.19-2.19

3,4
3,4
3,4
3,4
4,5
3,4
4,5,6
3,4
5,6
4,5,6
5,6
5,6
4,5,6
5,6
4,6,8
4,5,6
5,6,8
5,6,8
5,6,8
6,8
8,10
4,6,8
6,8
4,6,8
6,8,10
6,8,10
5,6,8
6,8,10
6,8,10
10
6,8,10
6,8,10
8,10
8,10,12
10,12
10,12
10,12
10,12

1st stg
Suct.
Add'l
Bowl
Pipe
Stage
Size Assembly Wt. Wt.
W/L
O/L
4
42 N/A
13
4
43 N/A
13
4
40 N/A
13
4
47
55
17
4,5
48
57
16
N/A
42
52
20
5
50
72
28
N/A
51
69
28
5
53
71
31
4
54
76
30
6
80
95
34
5
75
90
33
N/A
67
82
36
5
77
92
34
6
126
160
56
N/A
66
126
46
6
144
182
64
6
150
188
70
6
138
176
58
8
140
170
64
8
195
225
64
N/A
141
176
76
6
130
165
60
6
126
160
56
8,10
240
265
97
N/A
216
231
103
8
229
254
90
8,10
263
295
124
10
275
300
129
10
255
320
129
6
240
265
95
8
250
275
95
10
315
380
150
N/A
374
459
164
12
405
490
169
10
493
568
195
10
493
568
195
10
493
568
195

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003

Lineshaft Turbine Bowl Assembly Data___________________________________________________________


Model
and
Size

Bowl Assembly Length

L0
14RJ
15F Bell
15F
Bowl
16B
16DH
Bell
16DH
Bowl
16DM
16F
16RG
18B
18C
18D
18GX
18H
18L
20B
20C
20E
20G
20H
24C
24D
24E
24F
24G
26G
28B
28C
28G
28T
30B

1.94 1.00-1.94
2.19 1.19-2.19
2.19 1.19-2.19

8,10,12
12,14
12,14

10
N/A
12,14

390
535
535

475
620
620

155
222
222

N/A N/A 10.00 14.00 N/A


4.25 N/A 12.75 15.25 N/A

10.25 C/F
C/F N/A
8.00 37.50 52.00 N/A

4.75 17.00 19.00


4.75 12.25 17.50

8.00
17.00

16.13
15.25

2.44 1.19-2.44
2.44 1.19-2.44

8,10,12
12,14

N/A
N/A

465
660

680
764

300
281

4.25 N/A 12.75 15.25 N/A

8.00 37.50 52.00 N/A

4.75 N/A

N/A

17.00

15.25

2.44 1.19-2.44

12,14

N/A

660

764

281

17.00
18.50
18.50
18.75
18.00
18.75
19.75
19.50
24.50
21.00
21.00
23.25
23.25
24.13
25.50
26.00
26.75
25.50
26.00
28.50
29.50
29.50
29.50
23.63
34.00

15.00
15.00
15.00
15.00
8.50
10.50
9.38
13.25
11.75
12.00
10.00
12.50
15.63
11.38
12.38
12.88
13.00
13.38
15.38
16.00
18.00
18.00
18.00
21.00
18.25

16.00
16.00
16.00
17.50
17.50
17.75
18.50
18.00
18.00
19.75
20.50
18.94
20.75
19.75
25.00
24.25
22.25
24.25
24.25
26.00
26.88
29.12
26.88
26.12
29.50

2.44
2.44
2.44
2.44
2.44
2.69
2.44
2.69
2.44
2.44
2.44
2.44
2.44
2.69
2.44
2.44
2.44
2.44
2.94
2.94
2.68
2.44
2.94
3.18
2.94

14
14
12,14
12,14,16
10,12,14,16
12,14,16
12,14,16
12,14,16
16,18
10,12
12,14,16,18
12,14,16
16
12,14,16
14,16,18,20
16,18,20
16,18,20
16,18,20
16,18,20
16,18,20,24
16,18,20
16,18,20
18,20,24
16,18,20
18,20,24

14
14
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

740
740
450
514
450
661
RF
648
616
730
720
600
714
665
1300
1570
1320
1120
1110
RF
1500
RF
RF
1260
1820

760
760
RF
742
680
905
RF
886
1020
N/A
1000
896
1150
965
1800
2150
RF
RF
1800
RF
2030
RF
RF
1860
2400

265
265
310
354
310
482
N/A
371
456
395
500
392
519
462
900
1090
880
780
770
RF
1050
RF
RF
870
1330

10.75
8.00
8.00
8.50
10.69
11.88
10.88
8.88
12.75
12.13
12.56
12.50
12.50
12.50
15.38
16.25
14.56
14.68
14.43
15.56
12.94
17.94
16.19
13.38
14.94

L6

46.25
49.25
47.63
36.13
37.25
43.63
38.00
44.63
39.00
37.56
RF
39.00
42.25
33.75
50.25
48.00
44.00
52.50
48.00
50.75
42.88
RF
52.75
54.25
42.88

L7

51.88
52.13
53.25
47.88
54.50
54.00
62.00
55.00
54.88
56.69
RF
54.88
63.25
52.88
71.25
67.50
54.50
82.50
67.50
RF
60.88
RF
RF
78.75
60.88

2.50
1.13
N/A
N/A
N/A
2.50
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

O1

4.50
8.63
8.63
3.63
5.56
4.25
3.12
7.88
2.38
3.13
5.22
3.50
3.13
2.25
6.38
5.75
3.94
8.44
3.31
3.81
3.81
3.81
3.94
10.6
5.56

16.25
17.00
17.00
17.00
17.00
18.50
18.75
17.00
26.25
26.25
20.00
21.00
21.00
19.00
24.00
27.25
26.00
24.00
24.75
26.00
27.75
27.75
27.63
22.25
32.12

All dimensions are in inches and weights in lbs.)


SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

Add'l
Stage
Wt.

13.63
14.75
14.75

12.75
15.50
N/A
N/A
N/A
13.63
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

L5

1st stg
Bowl
Assembly
Wt.
W/L O/L

10.00
16.00
16.00

15.25
15.25
16.38
13.00
16.38
16.75
18.75
17.63
18.63
16.31
19.13
18.00
21.50
14.50
23.25
22.75
21.00
24.00
24.75
26.88
22.00
27.13
27.88
25.00
24.00

L4

Suct.
Pipe
Size

3.13 3.00 9.00 11.50 10.38 6.25 31.75 43.63 1.13 5.25 9.75 14.00
5.75 N/A 13.00 16.00 N/A
8.00 38.50 51.75 N/A 4.75 12.25 17.50
5.75 N/A 13.00 16.00 12.63 N/A 45.25 58.50 5.38 N/A N/A N/A

9.88
9.88
9.88
11.25
11.25
9.88
9.88
9.88
9.88
N/A
9.88
9.88
15.00
13.13
15.00
13.50
15.00
24.00
13.50
RF
12.00
RF
RF
18.50
12.00

L3

Col. Pipe
Size

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

L2

Floor
Bowl Bowl Available
Clearance O.D. Shaft Lineshaft
Dia.
Size
X

10.25
13.00
10.25
5.50
N/A
5.50
NA
5.50
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

L1

Basket
Strainer
(Optional)

1.19-2.44
1.19-2.44
1.19-2.44
1.19-2.44
1.68-2.43
1.19-2.69
1.68-2.44
1.19-2.69
1.19-2.44
1.19-2.44
1.68-2.43
1.19-2.44
1.19-2.44
1.19-2.69
1.68-2.43
1.68-2.43
1.68-2.43
1.68-2.43
1.68-2.93
1.68-2.93
1.68-2.68
1.68-2.43
1.68-2.93
1.68-3.18
1.68-2.93

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003
Permormance Correction Factors
Use the multipliers listed below to de-rate head, capacity and efficiency for special materials
bowls and impellers. Apply both multipliers listed if both bowl and impeller are of special construction.
Bowl Multiplier
MODEL

C.I. CL30 without


Enamel or Coating

5C,5T,
5WA,6C,6D,6RA
7C,7RA,7T,7WA
8DH
8RA,8RJ,8I
9RA,9WA,9RC,9T
10DH
10RA,10WA
10RJ
10L
11C,11WA
11RA
12C,12DH,12FR
12WA,12RJ
13C,13RA
14DH, 14F,14H,14RH14RJ
15F,16F
16B
16DH
18B,18G, 18H,18L
18D
20B,20C,20H
20E, 20G
24C, 24D, 24E, 24F, 24G
28B, 28C, 28G, 28T
30B

1.00
0.98
0.98
0.98
0.98
0.98
0.99
0.98
0.98
0.99
0.99
0.98
0.99
0.99
0.98
0.99
0.99
0.99
1.00
0.99
1.00
0.99
0.98
0.99
0.99
0.99

Impeller Multiplier

D.I. and other


Material without
Enamel or Coating
0.99
0.97
0.97
0.97
0.97
0.97
0.98
0.97
0.98
0.98
0.98
0.97
0.98
0.98
0.97
0.98
0.99
0.98
0.99
0.99
1.00
0.99
0.98
0.98
0.98
0.98

C.I. CL30,
Aluminum-Brz

D.I. and other


Material

0.98
0.98
0.98
0.99
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.00
0.99
0.99
0.99
0.99
0.99
0.99
0.99

0.98
0.97
0.97
0.97
0.97
0.97
0.98
0.97
0.98
0.98
0.98
0.97
0.98
0.98
0.97
0.98
0.97
0.97
0.99
0.97
0.97
0.97
0.97
0.98
0.98
0.98

Example:
Customer's rating is 1000 GPM at 50 ft. head with a 316 SS bowl
and impeller construction. A 12RJMO at 1760 RPM was selected.

Referring to the bowl assembly performance


curve, the efficiency at the corrected rating is

From the table, both the bowl and impeller correction is 0.98.
To determine pump efficiency, the rating must be corrected:

85% minus 3 points de-rate for one stage which


equals 82%. This efficiency must now be derated:

Corrected capacity = 1000 GPM


0.98 x 0.98
Corrected head
=
50 ft.
0.98 x 0.98

= 1041 GPM

The pump efficiency = 82% x 0.98 x 0.98 = 78.8%


Therefore, the pump performance is 1000 GPM,
50 ft. and 78.8% efficiency.

= 52 ft.
BHP = 1000 x 50 = 16.02 HP
3960 x 0.788

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003
Bowl Assembly Pressure Limits

__________________________________________________________

Maximum Bowl Working Pressure (PSIG) *1

MODEL
5C
5T,5WA
6C
6DH *2
6RA
7C
7RA
7T
7WA
8DHC
8DHO *2
8I
8RA
8RJ
9B
9RA
9WA
9RC
9T
10DH
10LC
10RA
10RJ
10WA
11C,11WA
11RA
12C
12DH
12FR
12WA
12RJ
13C
13RA

Ductile Iron *3
Double Bolting
Std Bolts (Grade 8) Std Bolts (Grade 8)
480
720
480
720
420
720
200
430
790
415
720
430
790
310
720
364
680
364
600
300
364
720
430
790
425
790
375
790
450
850
530
920
400
860
530
920
322
600
244
500
450
850
430
790
375
790
380
680
400
632
340
680
327
600
300
600
390
720
340
632
327
632
430
680

Maximum Bowl Working Pressure (PSIG) *1

Cast Iron CL 30

Cast Iron CL 30
MODEL
14DH
14F
14H
14RH
14RJ
15F
16DH
16DM
16B
16F
16RG
18C
18B
18D
18G
18H
18L
20B
20C
20E
20G
20H
24C
24D
24E
24F
24G
26G
28B
28C
28G
28T
30B

Std Bolts (Grade 8)


330
330
330
330
340
260
240
335
322
420
420
275
348
308
225
373
160
327
250
380
300
307
247
256
344
320
302
200
285
200
180
290
216

Ductile Iron *3
Double Bolting
Std Bolts (Grade 8)
700
700
700
700
720
410
480
620
643
750
750
656
562
293
537
636
650
534
524
430
492
603
470
550
500
440
540

Notes:
1. Pressure units based on maximum operating pressure of pump at any point on performance curve, normally occurring at
shutoff.
2. Threaded bowl connection.
3. To insure proper sealing at bowl mating surfaces:
Either O-ring or liquid gasket material recommended on all ductile iron, double-bolted bowl assemblies.

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003
Minimum Submergence Required for Vortex Suppression

NOTES: 1. Submergence values above are for vortex free operation. Check performance curves for NPSH required.
Submergence to satisfy NPSH requirement may be greater than S.
2. Minimum submergence is based on 2 times the bell distance between pump centerlines and other ideal flow
conditions. Refer to latest H. I. Standard on Intake Design or refer to factory for more information
regarding your particular installation, as less than ideal conditions will require additional submergence.

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003
Turbine Impeller Mechanical Data

MODEL
5C

Allowable
Allowable Eye
Lateral (in)
Sphere
Area
(in)
(sq. in)
Bearing Type
Bronze Rubber
0.25
NA
0.22
3.08

_____________________________________________________

Impeller Weight
(lbs.)

Impeller Identification

Wet
WR2
(lb-ft2)
0.03

L
3.72

A = Inches
M
-

H
3.72

B = Inches
L
M
H
0.43
0.43

No. of Vanes
L
M
H
5
8

3.54

0.62

0.62

Closed
2.00

Open
NA

2.40

NA
NA

5T

0.25

NA

0.43

5.02

0.03

3.54

5WA

0.50

0.50

0.15

1.62

0.05

4.00

4.00

0.21

0.21

2.40

6C

0.38

0.25

0.22

4.05

0.07

4.22

4.22

0.46

0.46

2.30

NA

6D

0.56

0.44

0.46

6.86

0.05

3.75

3.75

1.00

1.06

1.50

2.20
NA

6RA

0.25

NA

0.15

1.62

0.05

4.00

4.00

0.21

0.21

2.40

7C

0.50

0.50

0.43

7.54

0.14

5.25

5.25

0.60

0.60

3.10

NA

7RA

0.25

NA

0.18

2.65

0.08

4.75

4.75

0.25

0.25

3.30

NA

7T

0.38

0.38

0.83

10.40

0.18

4.93

4.93

1.26

1.26

5.10

NA

7WA

0.50

0.31

0.29

5.04

0.25

5.40

5.40

0.49

0.49

4.20

NA

8D

0.56

0.56

0.46

13.48

0.21

5.06

5.06

1.31

1.31

6.80

4.50

8I

0.62

0.44

0.25

6.10

0.22

6.03

6.03

0.44

0.44

5.70

NA

8RA

0.25

0.25

0.25

3.08

0.16

5.50

5.50

0.28

0.28

3.60

NA

8RJ

0.56

0.44

0.43

8.51

0.29

5.25

5.25

0.71

0.71

5.70

4.20

9B

0.63

0.44

0.45

8.60

0.58

7.31

7.31

0.73

0.73

7.90

NA

9RA

0.31

0.31

0.31

5.05

0.25

5.56

5.56

0.38

0.38

6.20

NA

9WA

0.56

0.56

0.40

6.84

0.45

6.69

6.69

0.46

0.46

11.50

NA

9RC

0.88

0.88

0.56

12.56

0.33

6.88

6.88

1.00

1.00

7.00

NA

9T

0.75

0.75

1.00

16.94

0.50

6.44

6.44

1.44

1.44

10.00

NA

10DH

0.75

0.75

0.68

20.92

0.97

6.37

6.37

1.62

1.62

14.00

NA

10L

0.50

0.50

0.62

27.18

0.94

5.81

1.68

10.50

NA

10RA

0.31

0.31

0.40

6.84

0.45

6.69

6.69

0.46

0.46

11.50

NA

10RJ

0.75

0.50

0.68

13.40

0.77

6.62

6.62

6.62

0.90

0.90

0.90

10.50

6.50

10WA

0.75

0.50

0.45

8.60

0.58

7.31

7.31

0.73

0.73

7.90

NA
10.00

11C

0.88

0.88

0.68

15.60

0.89

8.13

8.13

8.13

0.90

0.90

0.90

13.00

11RA

0.37

0.37

0.50

9.90

1.00

8.00

8.00

0.55

0.55

13.00

NA

11WA

0.75

0.75

0.50

11.20

0.93

8.38

8.38

0.82

0.82

11.60

NA

12C

1.00

0.88

0.73

20.43

1.65

8.69

8.69

8.69

1.20

1.20

1.20

18.00

14.50

12DH

1.00

0.88

0.81

31.47

2.36

7.75

7.75

2.00

2.12

19.50

19.50

Continue on next page

MODEL
12FR

Allowable Eye
Allowable
Sphere
Area
Lateral (in)
(in)
(sq. in)
Bearing Type
Bronze Rubber
1.00
0.88
0.81
38.3

Wet
WR2
(lb-ft2)

Impeller Weight
(lbs.)

Impeller Identification

2.42

L
-

A = Inches
M
-

H
7.25

L
-

B = Inches
M
H
2.12

No. of Vanes
L
M
H
8

Closed
19

Open
16

12WA

0.75

0.68

0.56

13.70

1.65

8.94

8.94

8.94

0.75

0.75

0.75

14

NA

12RJ

1.00

0.88

0.81

19.91

1.63

8.00

8.00

8.12

1.09

1.09

1.09

18

11
NA

13C

0.88

0.75

0.75

19.78

1.69

9.20

9.20

9.20

1.00

1.00

1.00

22

13RA

0.50

0.50

0.56

20.21

1.69

9.63

9.63

0.66

0.66

18

NA

14DH

1.00

1.00

0.87

43.42

3.72

9.06

9.06

2.31

2.31

NA

26.5
NA

14F

1.00

1.00

1.50

49.00

5.10

9.88

2.31

29

14H

0.75

0.75

1.18

36.06

5.05

9.88

1.62

29

29

14RH

1.00

1.00

1.18

38.00

5.05

9.88

9.88

9.88

1.62

1.62

1.62

32

28

14RJ

1.31

1.31

0.98

30.24

3.12

9.82

9.82

9.82

1.34

1.34

1.34

27

27

15F

1.25

1.25

1.62

70.00

8.70

9.75

3.00

30

NA

16B

0.88

0.88

0.75

29.50

11.44

12.25

12.25

1.03

1.03

60

NA

16DH

0.88

0.88

1.00

57.96

9.33

10.44

10.44

2.68

2.68

48.5

48.5

16DM

0.75

0.75

0.72

40.37

9.65

11.62

1.41

62

NA

16F

1.00

1.00

1.62

74.00

14.10

10.19

3.13

70

NA

16RG

1.00

1.00

1.20

58.13

10.45

10.45

2.22

2.22

NA

18B

0.75

0.75

1.12

46.90

13.96

12.94

12.94

1.28

1.28

88

NA

18D

0.75

0.75

0.75

49.00

13.30

12.75

12.69

1.55

1.75

60.7

NA

18GX

1.14

1.14

1.37

92.65

13.0

12.12

2.52

18H

0.75

0.75

1.75

68.40

21.68

12.62

2.50

65

NA

18L

1.12

1.12

1.25

78.40

18.04

10.41

2.78

87.5

NA

20B

0.81

0.81

1.00

38.25

19.32

14.25

1.26

95

NA
NA

NA

20E

0.88

0.88

1.75

80.70

17.16

13.31

13.31

1.97

1.97

68

20G

1.38

1.38

1.56

99.90

15.80

13.50

13.50

3.00

3.00

77

NA

20H

0.87

0.88

1.50

72.40

21.68

14.00

14.00

14.00

1.75

1.75

1.75

74

NA

24C

1.13

1.13

1.62

86.12

68.50

19.00

19.00

1.94

1.94

138

NA

24D

1.18

1.18

1.00

95.65

69.9

17.38

2.09

158

NA

24DX

1.18

1.18

1.00

155.52

69.9

18.22

2.52

158

NA

24E

0.63

0.63

2.00

87.27

52.12

15.56

15.56

2.29

2.29

82.5

NA

24F

1.37

1.37

2.75

126.47

52.12

16.11

116

NA

24G

1.50

1.50

1.75

138.71

40.5

15.81

15.50

3.38

3.45

150

NA

24GX

1.62

1.62

1.75

161.86

40.5

15.78

3.38

150

N/A

26G

1.37

1.37

1.50

162.05

84

17.62

3.54

249

249

28B

1.13

1.13

1.50

145.67

90.31

19.44

19.44

2.46

2.46

148.8

NA

28C

1.00

1.00

1.75

118.87

94.8

22.25

271

NA

28G

1.50

1.50

1.75

174.48

96.5

18.26

3.67

28T

0.81

0.81

1.87

120.0

22.48

15.75

15.75

3.12

3.12

30B

1.00

1.00

1.87

172.0

133.0

20.12

20.12

3.5

3.5

238

238

104

104

220

NA

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003

Low NPSH Impellers


Bowl Model

Low NPSH Impeller

9RALC, 9RAHC
10RALC, 10RAHC
11RAHC, 11RALC
12RJLC
12RJMC, 12RJHC
12DHHC, 12DHLC
12WALC, 12WAMC, 12WAHC
13RALC, 13RAHC
14DHLC
14RHLC,14RHMC, 14RHHC
14RJLC,14RJMC, 14RJHC
16BLC, 16BHC
16DHLC
16DMC
18BLC, 18BHC
18CHC
20BHC
16RGLC, 16RGHC
18DMC, 18DHC
20CLC, 20CHC
18HMC
18LHC
20GHC, 20GLC
24DMC
28BLC, 28BHC
24GLC, 24GHC
26GHC
28GHC

9RAXC
10RAXC
11RAXC
12DX
12WAHX
13RAXC
14DXC

16DXC

16GHX
18DXC
18HXC
18LHXC
20GHXC
24DXC
24GHXC
26GHXC
28GHXC

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2003

Calculating Axial Thrust


Axial thrust is a force caused mainly by the differences in pressure that exist between the suction side and discharge
side of an impeller. Axial thrust can be very small for double suction type impellers where flow enters both sides of
the impeller. Axial thrust for the vertical turbines can be quite large depending upon the impeller design, the
generated differential head., the pump length and several other factors.
Under normal circumstances vertical turbine Pump has a thrust load acting parallel to the pump shaft and in a
downward direction. The load is due to unbalanced pressures, dead weight and liquid direction change. Optimum
selection of the motor bearing and correct determination of the required bowl lateral for deep setting pumps require
accurate knowledge of the magnitude and direction of these forces. In addition, but with a less significant role, thrust
influences shaft horsepower rating and shaft critical speeds.
The components of the axial thrust are:
1.
2.
3.
4.

Hydraulic thrust (usually down)


Dead weight (always down)
Shaft thrust (usually up)
Sleeve thrust (always up)

We will discuss each of these components separately.


HYDRAULIC THRUST
The largest component of the axial thrust is usually the hydraulic thrust produced by the impeller. Most of time the
hydraulic thrust of an impeller is in the downward direction is due to the unbalanced pressure acting on the surfaces of
the impeller ( See the picture below).

The higher discharge pressure pushes down on the top side of the impeller while lower pressure pushes up on the
suction. The result of these two forces is always thrust toward the suction side of the impeller (downward direction for
the vertical turbines).
We obtain hydraulic thrust by multiplying the thrust factor ( K-factor) by the pressure differential across the impeller
measured in feet (total dynamic head of the pump) and times the specific gravity of the liquid being pumped. The Kfactor is shown on each performance curve. It is either estimated by analyzing the geometry of the impeller or
determined by test.
Hydraulic Thrust = K x TDH x S.G.

DEAD WEIGHT
In addition to the hydraulic thrust produced by the impeller, the dead weight of the impellers and the entire shaft
assembly weight are acts downward. The shaft assembly weight is calculated by multiplying the length of the column
assembly times the weight of the shaft per foot from table on page 200.B2. The bowl assembly shaft and the head
shaft weights are usually insignificant. The total impeller weight equals impeller weight from impeller data page (page
10 of this Section.) times the number of stages.
SHAFT THRUST
Shaft thrust occurs because different pressures act on the different places on the shaft assembly. Suction pressure
pushes up on the bottom of the bowl assembly shaft. Discharge pressure pushes down on the bowl assembly shaft
where it is turned down to couple to the lineshaft. Since the top of the shaft assembly is pushed down only by the
atmospheric pressure, up-thrust can occur where high suction pressure exists. The shaft up-thrust can be calculated
as shown below:
Shaft Up-thrust = Pump-shaft cross-section area X Suction pressure
- Shaft step area x Discharge pressure

SLEEVE THRUST
Finally, there can be an upward force across a head shaft sleeve or mechanical seal sleeve. For most applications,
these forces are small; however, when there is a danger of up-thrust or high suction pressure, these forces can be
significant.
The sleeve up-thrust can be calculated by multiplying the sleeve area in square inches times the pressure differential
across the sleeve.
Sleeve Up-thrust = Sleeve Area x Discharge Pressure
TOTAL PUMP THRUST
Total pump thrust is the sum of the component we discussed above:
Total Thrust = Hydraulic thrust (down)
+ Dead weight (down)
- Shaft thrust (up)
- Sleeve thrust (up)
Note that if total thrust is negative or in the up direction, the pump will not operate properly. Vertical turbine pump
shaft will not run straight under compression. Something must be done to prevent operation at any point where upthrust exist. A simple solution is to restrict the operation of the pump to flows where no up-thrust occur. Alternate
solutions are to eliminate the shaft sleeve or try to reduce the pressure on the bottom of the shaft.
NOTE: If you are using a low NPSHR first stage, the impeller K-factor for the first stage will be different from the
upper stages. You will need to do separate calculations for the first stage and add to the calculation for the additional
stages.

Vertical Turbine Pumps


Engineering Data
Effective April 1, 2002

Cone Strainers

Threaded Basket Strainer

Pipe Size
4
5
6
8
10
12
14

"A"
12.87
14.00
16.75
20.00
30.75
32.75
44.75

Pipe Size
4
5
6
8
10
12
14

Footvalve with strainer


B

Pipe Size
4
5
6

"A"
11.50
14.50
17.00

"B"
5.25
6.50
7.75

"A"
6.0
7.0
9.0
11.0
13.0
15.0
15.0

"B"
8.0
10.0
10.0
12.0
18.0
18.0
20.0

You might also like