4.1.

1 Analisa data standart AWS


1. Calculate the sensitivity level (EPS) for radiograph.
EPS =

Diameter wire terkecil


tw
0,41
14

x 100%

x 100%

= 2,93 %
2. What is the wire ID or wire diameter that must appear on radiograph? (based
on your calculation).
wire = 0,41mm
Wire diameter must appear = 4
3. Calculate the Ug based on the parameters given.
Ug =

F x tw
SOD
4,2 x 14
400

= 0,15

4.1.1 Analisa data standart ASME


1. Calculate the sensitivity level (EPS) for radiograph.
EPS =

Diameter wire terkecil


tw
0,41
14 ,5

x 100%

x 100%

= 2,83 %
2. What is the wire ID or wire diameter that must appear on radiograph? (based
on your calculation).
Wire ID = #8
wire = 0,41mm
Wire diameter must appear = 4
3. Calculate the Ug based on the parameters given.
Ug =

F x tw
SOD
4,2 x 14
400

= 0,15