Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Utilisation Factor Table

Luminaire
Lamp
Lampflux
Measurement code
Measurement date
Measurement status

: TBS160 4x18W M1
: 4 x TL-D18W/840 / 840
: 4 x 1350 lm
: LVN8828200
:
: Unknown

Utilisation factor table


Reflectances (%) for ceiling, walls and working plane (CIE)
Room
Index
k

0.80
0.50
0.30

0.80
0.50
0.10

0.70
0.50
0.30

0.70
0.50
0.20

0.70
0.50
0.10

0.70
0.30
0.10

0.50
0.30
0.10

0.50
0.10
0.10

0.30
0.30
0.10

0.30
0.10
0.10

0.00
0.00
0.00

0.60
0.80
1.00
1.25
1.50
2.00
2.50
3.00
4.00
5.00

0.37
0.44
0.51
0.56
0.60
0.67
0.71
0.73
0.77
0.79

0.35
0.42
0.47
0.52
0.55
0.59
0.62
0.64
0.66
0.68

0.36
0.44
0.50
0.55
0.59
0.65
0.69
0.71
0.74
0.76

0.36
0.43
0.48
0.53
0.57
0.62
0.65
0.67
0.70
0.71

0.35
0.41
0.46
0.51
0.54
0.59
0.62
0.64
0.66
0.67

0.30
0.37
0.42
0.47
0.51
0.56
0.59
0.61
0.64
0.66

0.30
0.37
0.42
0.47
0.50
0.55
0.58
0.60
0.63
0.64

0.27
0.34
0.39
0.44
0.47
0.53
0.56
0.59
0.62
0.63

0.30
0.36
0.41
0.46
0.49
0.54
0.57
0.60
0.62
0.63

0.27
0.33
0.39
0.43
0.47
0.52
0.56
0.58
0.61
0.62

0.26
0.32
0.37
0.42
0.46
0.51
0.54
0.57
0.59
0.61

Ceiling mounted

CalcuLuX Photometrics 4.1

Philips Lighting B.V.

Page: 1/5

Utilisation Factor Table


Luminaire
Lamp
Lampflux
Measurement code
Measurement date
Measurement status

: TBS160 2x36W M1
: 2 x TL-D36W/840 / 840
: 2 x 3350 lm
: LVN8828200
:
: Unknown

Utilisation factor table


Reflectances (%) for ceiling, walls and working plane (CIE)
Room
Index
k

0.80
0.50
0.30

0.80
0.50
0.10

0.70
0.50
0.30

0.70
0.50
0.20

0.70
0.50
0.10

0.70
0.30
0.10

0.50
0.30
0.10

0.50
0.10
0.10

0.30
0.30
0.10

0.30
0.10
0.10

0.00
0.00
0.00

0.60
0.80
1.00
1.25
1.50
2.00
2.50
3.00
4.00
5.00

0.36
0.44
0.50
0.55
0.59
0.66
0.70
0.72
0.76
0.78

0.35
0.41
0.46
0.51
0.54
0.59
0.61
0.63
0.65
0.67

0.36
0.43
0.49
0.54
0.58
0.64
0.68
0.70
0.73
0.75

0.35
0.42
0.47
0.52
0.56
0.61
0.64
0.66
0.69
0.70

0.34
0.41
0.46
0.50
0.53
0.58
0.61
0.63
0.65
0.66

0.30
0.36
0.42
0.46
0.50
0.55
0.58
0.61
0.63
0.65

0.30
0.36
0.41
0.46
0.49
0.54
0.57
0.60
0.62
0.63

0.27
0.33
0.38
0.43
0.47
0.52
0.56
0.58
0.61
0.62

0.29
0.36
0.41
0.45
0.49
0.54
0.57
0.59
0.61
0.62

0.27
0.33
0.38
0.43
0.46
0.52
0.55
0.57
0.60
0.61

0.26
0.32
0.37
0.42
0.45
0.50
0.54
0.56
0.58
0.60

Ceiling mounted

CalcuLuX Photometrics 4.1

Philips Lighting B.V.

Page: 2/5

Utilisation Factor Table


Luminaire
Lamp
Lampflux
Ballast
Measurement code
Measurement date
Measurement status

: TCS398 2x58W WH D6
: 2 x TL-D58W / 840
: 2 x 5200 lm
: HF Performer
: LVW1155600
: 1998-12-03
: Released

Utilisation factor table


Reflectances (%) for ceiling, walls and working plane (CIE)
Room
Index
k

0.80
0.50
0.30

0.80
0.50
0.10

0.70
0.50
0.30

0.70
0.50
0.20

0.70
0.50
0.10

0.70
0.30
0.10

0.50
0.30
0.10

0.50
0.10
0.10

0.30
0.30
0.10

0.30
0.10
0.10

0.00
0.00
0.00

0.60
0.80
1.00
1.25
1.50
2.00
2.50
3.00
4.00
5.00

0.41
0.49
0.55
0.60
0.64
0.70
0.73
0.76
0.78
0.80

0.39
0.46
0.51
0.55
0.58
0.62
0.65
0.66
0.68
0.69

0.40
0.48
0.54
0.59
0.63
0.68
0.71
0.74
0.76
0.78

0.39
0.46
0.52
0.57
0.60
0.65
0.68
0.69
0.71
0.72

0.38
0.45
0.50
0.55
0.58
0.62
0.64
0.66
0.67
0.68

0.34
0.41
0.47
0.51
0.55
0.59
0.62
0.64
0.66
0.67

0.34
0.41
0.46
0.51
0.54
0.59
0.61
0.63
0.65
0.66

0.32
0.38
0.44
0.49
0.52
0.57
0.60
0.62
0.64
0.65

0.34
0.41
0.46
0.50
0.53
0.58
0.60
0.62
0.64
0.65

0.31
0.38
0.43
0.48
0.52
0.56
0.59
0.61
0.63
0.64

0.30
0.37
0.42
0.47
0.50
0.55
0.58
0.60
0.61
0.62

Ceiling mounted

CalcuLuX Photometrics 4.1

Philips Lighting B.V.

Page: 3/5

Utilisation Factor Table


Luminaire
Lamp
Lampflux
Ballast
Measurement code
Measurement date
Measurement status

: FBS291 M
: 2 x PL-C/4P26W / 840
: 2 x 1800 lm
: HF Performer
: LVF0114400
: 2002-01-02
: Released

Utilisation factor table


Reflectances (%) for ceiling, walls and working plane (CIE)
Room
Index
k

0.80
0.50
0.30

0.80
0.50
0.10

0.70
0.50
0.30

0.70
0.50
0.20

0.70
0.50
0.10

0.70
0.30
0.10

0.50
0.30
0.10

0.50
0.10
0.10

0.30
0.30
0.10

0.30
0.10
0.10

0.00
0.00
0.00

0.60
0.80
1.00
1.25
1.50
2.00
2.50
3.00
4.00
5.00

0.29
0.35
0.40
0.44
0.48
0.52
0.55
0.57
0.60
0.61

0.27
0.33
0.37
0.41
0.43
0.47
0.49
0.50
0.52
0.52

0.28
0.34
0.39
0.43
0.46
0.51
0.54
0.56
0.58
0.59

0.27
0.33
0.38
0.42
0.44
0.48
0.51
0.52
0.54
0.55

0.27
0.32
0.36
0.40
0.43
0.46
0.48
0.50
0.51
0.52

0.23
0.29
0.33
0.37
0.40
0.44
0.46
0.48
0.50
0.51

0.23
0.29
0.33
0.37
0.39
0.43
0.46
0.47
0.49
0.50

0.21
0.26
0.31
0.35
0.38
0.42
0.44
0.46
0.48
0.49

0.23
0.28
0.33
0.36
0.39
0.43
0.45
0.47
0.48
0.49

0.21
0.26
0.31
0.34
0.37
0.41
0.44
0.46
0.47
0.48

0.20
0.25
0.30
0.33
0.36
0.40
0.43
0.44
0.46
0.47

Ceiling mounted

CalcuLuX Photometrics 4.1

Philips Lighting B.V.

Page: 5/5