Professional Documents
Culture Documents
Vortex
Vortex
Vortex
Item No.
Tag No.
Rgst. No.
Quantity
not select
50mm 2in
Liquid
Other Liquid
25
5
95.0
10
10
920
30
0
0
23.557
:E10
:C20,F10
:C45,B10,F40
:C31,D21
:C26,D26,F27
:B45
:B21
:D10
m3/h
m3/h
degC
mbar abs
bar gauge
kg/m3
cP
m3/pulse
m3/pulse
m3/h
Turn down
CAVITATION
15mm 1/2in
25mm 1in
40mm 1-1/2
50mm 2in
80mm 3in
0
20
Measurable Zone
Min. Flow Rate
(* Refer to GS01F06A00-01E)
Nominal Size
Result
Reason of NG
Reynolds Number at Max. Flow
Maximum Measurable Flowrate(m3/h)
Minimum Measurable Flowrate(m3/h)
Flow Velocity at Maximum Flowrate(m/s)
Minimum Measurable Flow Velocity(m/s)
Min. Flow for Specified Accuracy(1.0%)(m3/h)
Min. Flow for Specified Accuracy(0.75%)(m3/h)
Predicted Error
at Low Reynolds Number(of reading)
40
60
80
100%
0.2
0.4
0.6
0.8
1.1
25mm 1in
No Good
No Range
10551
18.675
11.848
13.387
6.344
47.390
91.345
+12.40%
17053 mbar
1776 mbar
312 mbar
114 mbar
30 mbar
Max.=25 m3/h
Pres. drop
40mm 1-1/2
No Good
No Range
6830
44.563
18.301
5.610
4.107
73.206
145.314
+12.40%
80mm 3in
No Good
Over Size
3819
142.531
32.731
1.754
2.296
130.922
464.775
+12.40%
CHECKED.BY
RE
YOKOGAWA
REMARKS
DATE REV.BY
Software Ver. Eng. 8.00 WS 01F06A00-01EN