Professional Documents
Culture Documents
User-Manual Item50288 en 3-2010
User-Manual Item50288 en 3-2010
User-Manual Item50288 en 3-2010
USB CARD
50288
S.p.A.
via Grieco 25/27 - 40024 Castel S. Pietro Terme - Bologna ITALY
Tel. +390516954411 Fax +390516954490 http://www.tecna.net
DOCUMENT
NUMBER:
EDITION:
DISTRIBUTOR:
MAN 4208
MARCH 2010
S.p.A.
ART. 50288
User Manual
2/20
User Manual
ART. 50288
S.p.A.
TABLE OF CONTENTS
CHAPTER 1 DESCRIPTION OF THE USB CARD......................... 4
1.1 MAIN FEATURES ......................................................................................... 4
3/20
S.p.A.
ART. 50288
User Manual
4/20
User Manual
ART. 50288
S.p.A.
FEATURES MENU
FIRST INSERT. 70
>SERIAL COM.
USB
NET ADDRESS
01
and the NET ADDRESS parameter to the control unit's ID number so as to
differentiate multi control units of the same type.
FEATURES MENU
FIRST INSERT. 70
SERIAL COM.
USB
>NET ADDRESS
01
The control unit compels the user to turn the machine on and off in order to activate
the functions of the USB card correctly.
RESTART
MACHINE
5/20
S.p.A.
ART. 50288
User Manual
FEATURES MENU
>BACKUP USB
<+>
RESTORE USB
<+>
SET DATE-TIME <+>
BACKUP USB
Use this parameter to save all the parameters inside the control unit directly to the
USB key. For any further information, refer to the specific chapter.
RESTORE USB
Use this parameter to call all the previously saved parameters directly from the USB
key. For any further information, refer to the specific chapter.
SET DATE-TIME
Use this parameter to set the time, day, month and year of the clock inside the USB
card. For any further information, refer to the specific chapter.
6/20
User Manual
ART. 50288
S.p.A.
FEATURES MENU
BACKUP USB
<+>
RESTORE USB
<+>
>SET DATE-TIME <+>
Use this key
in the SET DATE-TIME parameter inside the FEATURES MENU to
access the following screen:
DESCRIPTION
VALUE RANGE
hh
00 23
mm
00 59
mm
01 12
dd
01 31
yy
00 99
and
to increase or decrease the single values or keys
Use keys
to move the cursor ^ to the right or to the left.
Press key
to save any modifications and exit from this menu.
and
7/20
S.p.A.
ART. 50288
User Manual
4.1 - BACKUP
Use the BACKUP USB function to save all the parameters, set inside the control
unit menus, to the USB key.
FEATURES MENU
>BACKUP USB
<+>
RESTORE USB
<+>
SET DATE-TIME <+>
First of all, insert the USB key and wait until it is recognized. If the backup
procedure is launched before the memory is ready, the following message will be
displayed for a few seconds.
Start the backup procedure after the USB key has been inserted and duly
recognized by the card.
The USB key must not be disconnected until the procedure is
finished otherwise saved data will not be guaranteed and data
will not
contained inside the USB key used might be lost.
be held liable for the improper use of the device.
8/20
User Manual
ART. 50288
On pressing key
S.p.A.
, the control unit begins transmitting all data to the USB key.
WAIT....
BACKUP PROGRAM:
023
The BACKUP OK message displayed on the control unit informs the user that the
backup procedure is finished and that the USB key may now be removed.
BACKUP OK
A FILE.BK is present inside the memory (for example 55023701.BK) and is made
up as follows:
generated
file
Example
File
extension
ID number of the control
unit set in the NET
ADDRESS parameter
(e.g. 01)
Software version of the control unit (e.g. 2.37)
Control unit model (e.g. TE550)
9/20
S.p.A.
ART. 50288
User Manual
Each time the software version of the control unit changes, the
user must repeat the BACKUP USB procedure otherwise it will
NOT be possible to carry out a file RESTORE USB with a different
version as compared to the one installed in the control unit.
If the BACKUP USB procedure is not carried out correctly, the control unit will
display the BACKUP FAIL message to inform the user that the procedure failed.
WAIT....
BACKUP FAIL
In this case, remove the USB key and repeat the procedure from the beginning.
10/20
User Manual
ART. 50288
S.p.A.
4.2 - RESTORE
Use the RESTORE USB function to call all previously saved data with a BACKUP
USB through the USB key and transmit them to the control unit.
FEATURES MENU
BACKUP USB
<+>
>RESTORE USB
<+>
SET DATE-TIME <+>
Each time the RESTORE USB procedure is carried out the control
unit cuts off power supply to the outputs to compel the user to
turn the control unit off and on.
First of all, backup the previously saved FILE.BK to a USB key.
The file must have the same typology (control unit, software
version and ID number) as the control unit in which the RESTORE
USB is carried out.
This procedure CANNOT be carried out with a FILE.BK of a
different software version as compared to the one installed in the
control unit.
Insert the USB key and wait until it is recognized. If the RESTORE procedure is
launched before the key is ready, the following message will be displayed for a few
seconds.
Start the RESTORE procedure once the USB key has been inserted and duly
recognized by the card.
The USB key must not be disconnected until the procedure is
finished otherwise saved data will not be guaranteed and data
contained inside the USB key and in the control unit might be lost.
will not be held liable for the improper use of the device.
11/20
S.p.A.
On pressing key
FILE.BK.
ART. 50288
User Manual
WAIT....
RESTORE PROGRAM:
176
The following message informs the user that the restore procedure was finished
correctly and that a key must be pressed to continue.
RESTORE OK
PUSH A KEY TO CONT.
Now the USB key may be removed. Turn off the control unit and then turn it on
again.
12/20
User Manual
ART. 50288
S.p.A.
But, if the RESTORE USB procedure is launched with a FILE.BK that does not
match the foregoing characteristics, a few seconds later the control unit displays the
RESTORE FAIL message to inform the user that the procedure failed.
WAIT....
RESTORE FAIL
PUSH A KEY TO CONT.
After having pressed a key, remove the USB key, turn off the control unit and then
turn it on again.
Repeat the procedure after having checked that the FILE.BK copied to the USB
key matches the characteristics (type of control unit, software version and ID
number) of the control unit in which the RESTORE procedure is carried out.
13/20
S.p.A.
ART. 50288
User Manual
14/20
User Manual
ART. 50288
S.p.A.
A FILE.TXT is created inside the USB key that saves all weld data of all welds
carried out by the control unit.
The name of the FILE.TXT (for example SPT55001.TXT) is made up as follows:
generated file
Example
File extension
ID number of the control unit
set in the NET ADDRESS
parameter (e.g.: 01)
Control unit (e.g.: TE550)
Abbreviation of SPOTS
Example of data saved during the welding cycle of a TE550 control unit:
PROG CYCLES CURRENT DEGREE ENERGY SPOTS THICKNESS INDENTATION LIMIT
001
001
002
002
003
003
004
004
05.0
05.0
04.0
04.0
10.0
10.0
08.0
08.0
12.88KA
12.91KA
05.17KA
05.17KA
02.84KA
02.88KA
09.96KA
09.94KA
096
096
062
062
048
048
085
085
00000J
00000J
00000J
00000J
00000J
00000J
00000J
00000J
00001
00002
00003
00004
00005
00006
00007
00008
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
------- 10:12:39
------- 10:12:41
CUR OK 10:12:42
CUR OK 10:12:44
CUR MIN 10:12:45
CUR MIN 10:12:47
CUR MAX 10:12:47
CUR MAX 10:12:47
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
08.0
03.0
03.0
03.0
03.0
03.0
03.0
09.94KA
03.12KA
03.12KA
03.11KA
03.11KA
03.12KA
03.11KA
085
049
049
049
049
049
049
00000J
00000J
00000J
00000J
00000J
00000J
00000J
00008
00009
00010
00011
00012
00013
00014
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
00.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
0.000mm
CUR MAX
-------------------------------------
10:12:47
12:44:57
12:44:59
12:45:01
12:45:03
12:45:04
12:45:07
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
04-02-10
15/20
S.p.A.
ART. 50288
User Manual
16/20
User Manual
ART. 50288
S.p.A.
3) CREATE an interruption line between the current value and the acronym [KA]
following the instructions supplied by the program and then press [Next>]
4) Here the user can select each column and set the data format.
Select the current column and go to settings [Advanced...]
After having confirmed the change, end the import procedure by clicking [End].
17/20
S.p.A.
ART. 50288
18/20
User Manual
User Manual
ART. 50288
S.p.A.
COMPULSORY
TO THROW AWAY EXPIRED BATTERIES INTO
THE SPECIFIC BATTERY RECYCLE BINS.
19/20
S.p.A.