Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A

B
8400

C
8400

8400

8400

G
92400
8400

8400

8400

8400

K
8400

L
8400

M
8400

4750

RC FLAT ROOF OF LIFT MOTOR ROOM


ALUM. TRELLIS

3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
3850
4200
4200
4200
4200

ALUM. CLADDING

ROOF LEVEL

WATER TANK ROOM

38TH STOREY LEV.

OFFICE

ALUM. FIN TO DETAIL

OFFICE

GLAZING AS SPECIFIC

37TH STOREY LEV.

OFFICE

OFFICE

36TH STOREY LEV.

OFFICE

OFFICE

35TH STOREY LEV.

OFFICE

OFFICE

34TH STOREY LEV.

OFFICE

OFFICE

33RD STOREY LEV.

OFFICE

OFFICE

32ND STOREY LEV.

OFFICE

OFFICE

31ST STOREY LEV.

OFFICE

30TH STOREY LEV.

OFFICE

29TH STOREY LEV.

OFFICE

28TH STOREY LEV.

OFFICE

27TH STOREY LEV.

OFFICE

26TH STOREY LEV.

OFFICE

25TH STOREY LEV.

OFFICE

24TH STOREY LEV.

OFFICE

OFFICE

LIFT MOTOR ROOM

MACHINE
ROOM

23RD STOREY LEV.

22ND STOREY LEV.

21ST STOREY LEV.

20TH STOREY LEV.

19TH STOREY LEV.

18TH STOREY LEV.

WATER TANK ROOM

17TH STOREY LEV.

LIFT MOTOR ROOM

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

MACHINE
ROOM

16TH STOREY LEV.

15TH STOREY LEV.

14TH STOREY LEV.

13TH STOREY LEV.


GLAZING AS SPECIFIC

GLAZING AS SPECIFIC

12TH STOREY LEV.

11TH SYOREY LEV.

10TH STOREY LEV.

9TH STOREY LEV.

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

LOBBY

"I have inspected the building and investigated its overall


structure and that, in my opinion, the building is capable
of resisting the forces and moments which may be
increased or altered by reason of the repairs, alterations
or additions shown on these plans".

8TH STOREY LEV.

7TH STOREY LEV.

6TH STOREY LEV.

5TH STOREY LEV.


GLAZING AS SPECIFIED

GLAZING AS SPECIFIED

4TH STOREY LEV.

OFFICE

3RD STOREY LEV.

OFFICE

GRANITE CLADDING
TO EXISTING WALL

EXISTING ROOF CANOPY TO BE


DEMOLISHED

2ND STOREY LEV.

30M WIDE WALKWAY

1ST STOREY LEV.

SHOPS

NEW ROOF CANOPY

LOBBY

2800

1ST BASEMENT LEV.


2ND BASEMENT LEV.

2800

3325

ALUM. FIN TO DETAIL

LIFT MOTOR ROOM

LIFT MOTOR ROOM LEVEL

3RD BASEMENT LEV.

LOBBY
CARPARK

DRIVEWAY

CARPARK

DRIVEWAY

CARPARK

FAN RM

LIFT
PIT

SERVICE
AREA

LOBBY
LIFT
PIT

DRIVEWAY

STORE

LOBBY

VOID

WATER TANK ROOM

LIFT
PIT

PUMP
ROOM
LIFT
PIT

LOBBY

LOBBY

PUMP ROOM

SERVICE
AREA

LIFT
PIT

LIFT
PIT

WATER TANK ROOM

SECTION C - C

22 SHEET OF 23

APPROVED UNDER SECTION 6 OF THE


BUILDING CONTROL ACT (CHAPTER 29)

BUILDING AND CONSTRUCTION AUTHORITY

Project Ref. No: A0537-031-1999-BP01

For Commissioner Of Building Control

RECORD OF DRAWINGS
APPROVED BY BCA
ON 08 NOVEMBER 2002

HONG LEONG PROPERTIES PTE LTD


36 ROBINSON ROAD #20-01
CITY HOUSE

OWNER'S SIGNATURE :

ADDRESS :

SECTION C - C

DRAWING TITLE :

PROJECT TITLE :

ARCHITECTS :

PROPOSED RECLADDING WORKS TO


THE EXISTING 38 STOREY IBM TOWERS
ON LOT 595 TS 03 AT 80 ANSON
ROAD

"I, Goh Peng Thong hereby certify, subject to any waiver/


modification granted under Section 14 of the Act, that the
preparation of these building plans and the building works
shown on these plans are strictly in accordance with the
provisions of the Building Control Act (Cap 29) and the
Regulations made thereunder".

GOH PENG THONG


B.Arch (S'pore) M.S.I.A.
Director

BP

STAGE :

APPROVED :
GPT

REV:

DIGITAL FILE NO

J1620BP00

00

ALFRED WONG PARTNERSHIP


AWP
PTE LTD
ARCHITECTS
CHARTERED

KCK/PO

CHECKED :

#12-02/04 PENINSULA PLAZA 111 NORTH BRIDGE ROAD (179098)

CONSULTANT REF NO. :

99AWP1

DATE : MARCH 2001

SCALE :
1 : 250

DRAWN :JP/JAMIE

99AWP1/BP/621

PROJ. ARCH. : KCK

DRAWING NO.

COPYRIGHT BY ALFRED WONG PARTNERSHIP PTE LTD . THIS DRAWING IS


THE PROPERTY OF ALFRED WONG PARTNERSHIP PTE LTD AND CANNOT BE
COPIED REPRODUCED PARTLY OR WHOLLY WITHOUT THE WRITTEN
PERMISSION OF ALFRED WONG PARTNERSHIP PTE LTD.

You might also like