Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CRAWLER CRANE DEFECT REPORT

STATUTORY INSTRUMENTS 1998 No. 2307


The Lifting Operations and Lifting Equipment Regulations 1998
STATUTORY INSTRUMENTS 1992 No. 3073
The Supply of Machinery (Safety) Regulations 1992
STATUTORY INSTRUMENTS 1998 No. 2306
The Provision and Use of Work Regulations 1998
REPORT NO: EG 3360/01

TESTER/EXAMINER: HASSAN ADEL

QUALIFICATION: LEEA&ASNT II

DATE OF TEST/EXAMINATION: 02/02/2012

TYPE OF CERTIFICATE: DEFECT REPORT


IDENTIFICATION NO

QTY

N/A

DESCRIPTION OF EQUIPMENT

SWL

CRAWLER CRANE

N/A

DATE OF NEXT
EXAMINATION

EXAMINED IN ACCORDANCE WITH BS 466 / 5744 /7121

ORIGINAL CERTIFICATE NO

ORIGINAL CERTIFICATE DATE

NAME OF CERTIFYING BODY

DATE OF LAST EXAMINATION

PARTICULARS OF DEFECTS FOUND WHICH ARE, OR COULD,


BECOME A DANGER TO PERSONS OR NONE
1-EXCESSIVE CORROSION IN BOOM STRUCTURE AND
CORROSION OF ALL STRUCTURE OF THE CRANE
2-BROKEN WIRES, DEFORMATION, CORROSION OF WIRE
3- DISTORTION OF THE BODY OF THE CRANE
4-INDICATOR ,LIMIT SWITCHES NOT FOUND
5- HOOK BLOCK &HOOK NOT STANDARD , NOT USED FOR
LIFTING OPERATIONS
6-DAMAGE OF CABIN ,FRAME, Hydraulic HOSES AND
CONNECTIONS
NAME AND ADDRESS OF EQUIPMENT OWNER:

PARTICULARS OF ANY REPAIR, ALTERATION TO REMEDY


DEFECT OR NONE

GUPCO

DAIMETTE

ADDRESS OF PREMISES WHERE TEST/EXAMINATION WAS


HELD:

We hereby certify that on 02/02/2012 the item/s described in this report was/were thoroughly examined, so far as accessible, and the above
particulars are correct. If installation is relevant, the equipment checked and examined is UNSAFE to operate.

SIGNATURE OF PERSON
CONDUCTING EXAMINATION
DATE: 02/02/2012

NAME OF PERSON: HASSAN ADEL


VISUAL

You might also like