Professional Documents
Culture Documents
PLL 1426
PLL 1426
PLL 1426
Table of Contents
Contents
Open Loop 4
Specifications and Performance
5
Model Code
6
Operational Parameters
9
Life time recommendations
9
Tank connection
10
Pressure Fluids
11
LSC-System 12
Noise reduction 13
SPU silencer
13
Torque Transmission 15
Mounting Flange
16
Drive shaft
17
PTO through drive
18
Output shaft
18
PTO flange and output shaft
19
Gear pumps 20
Type of control 23
Load sensing LS
24
LP. LS with hydraulic pressure cut-off LP
25
E1L/H1L. Load Sensing with electric /hydraulic override
26
E1L. Load Sensing with electric override
27
H1L. Load Sensing with hydraulic override
28
Pump controllers with position feedback
29
TL2. Load Sensing with hyperbolic power limitation
30
Electrical properties
31
Pump controllers with position feedback
32
LEP. Load sensing with electro-proportional flow
33
limitation and pressure cut-off
ETP. Electro-proportional flow setting,
34
power limitation and pressure cut-off
Dimensions
LP-controller
35
H1L-controller
36
E1L-controller
37
TL2-controller
38
LEP- controller
39
Single pumps HPR-02 for LP, E1L, H1L
41
Single pumps HPR-02 for TL2, LEP, ETP
43
Double pumps and plug-in pumps
45
Multiple pumps
47
Modular System Features 49
Notes 50
LS-Controller
Design Characteristics
Optimum utilization
Swash Plate
Hydrostatic bearing
Piston-Slipper Assembly
21 swash angle
Housing
One piece design for high rigidity
Highly integrated
Actuator Piston
Power Take-Off
Dynamic response
Cylinder Barrel
Compact due to 21 technology
Suction Port
Optimized suction capacity without
tank pressurization
10 SPU
Reduced of pressure pulsation over the entire
operating range
Open loop
Function Diagram
B
A
B
B
Tank
Filter Cooler
LS
HPR R E1L
U
LS
P
T
Circuit Diagram
Tank
Filter Cooler
L
X1
LS2
X
LS1
T
LS
P
HPR R E1L
Manifold
Manifold
Specifications
Model
Rated Size
Maximum Displacement
cm 3 /rev
Speed* min -1
Volume Flow
Max. oil flow
1/min
Pressure
Nominal Pressure
bar
Peak Pressure
bar
Permissible Housing Pressure (absolute)
bar
Power**
Continous Power
Maximum Power
Input Torque
Max. Input torque at max.
operating pressure and Vmax
Response Times**
Vmax -> Vmin swashing at
constant max. system pressure HP
Vmin -> Vmax swashing from stand-by
pressure and zero outlet flow to
constant max. system pressure HP
Permissible Shaft Loads
Axial
Radial
Perm. Housing Temperature
Perm. Housing Temp. with min.
perm. viscosity > 10 cST
Weights
HPR without oil (approximate)
Maximum moment of inertia
189.8
246.8
312.1
347.8
420.2
507.4
493.5
695.5
kW
kW
61.9
104
79.1
132.8
102.8
172.7
130
218.5
144.9
243.4
175.1
294.1
211.4
355.2
205.6
306.7
289.8
431.8
Nm
368
507
702
907
1107
1404
1884
1245
1964
HP 100 bar ms
HP 200 bar ms
HP 100 bar ms
HP 200 bar ms
120
70
180
160
120
70
180
180
120
70
180
160
140
70
180
160
150
130
180
160
200
170
180
160
300
270
430
350
200
170
160
160
150
130
180
160
90
kg
kgm 2 x 10 -2
39
39
50
65
89
116
165
96
177
0.79 0.79 1.44 2.15 3.41 4.68 8.34 2.88 6.88
90
90
90
90
90
90
90
90
* Max. operating speed (rated speed) without tank pressurization Operating speed with tank pressurization see chapter operational parameters.
** Measured at fluid viscosity 20 cST and input speed 1500 rpm.
Performance Data
800
165D
700
600
500
105D
210
400
165
300
135
105
75
200
55
100
0
1450
1650
1850
2050
2250
2450
2650
2840
Model code
HPR Self-regulating Pump for Open Loop Operation
4 5 6
Product
9 10
11
12 13 14 15 16 17 18 19
20
21
23 24 25 26 27 28
22
HPR O
pen Loop Variable
Displacement Pump
4
055
075
105
135
165
210
280
7
R
L
8
0
1
2
3
4
5
6
9
S1
S2
S3
S4
T1
T2
T3
T4
K1
K2
11
M
D
12
A
B
C
D
E
F
Displacement
055 cc/r
075 cc/r
105 cc/r
135 cc/r
165 cc/r
210 cc/r
280 cc/r
Rotation
cw
ccw
l
l
l
l
l
l
l
l
Mounting Flange
Porting
Pump Control
17 18 19
20
l
l
0
D
R
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l l l l l
l l l l l
Available Option l Preferred Option t Separate Specification Required
l
l
l
l
1
2
21
l
l
l
38
l
l
l
l
l
l
l
l
l
l
l
l
000
value
value
value
10 Input Shaft
15 16
00
AC
37
Pressure Compensator
Setting (125-420)
00
AE
AM
AA
AD
AY
AJ
BN
BA
AH
BC
AC
36
33 34 35
29 30 31 32
22
0
A
B
C
D
E
F
Control Solenoids
Model code
HPR Self-regulating Pump for Open Loop Operation
4 5 6
9 10
11
12 13 14 15 16 17 18 19
20
21
23 24 25 26 27 28
22
0
1
24 25
0G
AA
AB
AB
AB
AB
AC
AD
AE
AF
AF
AF
AG
AG
AG
AH
AJ
AJ
AJ
AJ
AK
AL
AM
AN
AP
AQ
AR
AS
AT
l
l
l
l
l
l
l
l
l
l
BD
BE
BF
BG
BH
BJ
BK
BL
BM
BN
BP
BQ
BR
B
C
E
F
29
0
E
without
l
internal gear pump 16 cc
l
00
BA
BB
BC
28
30 31 32
Maximum Displacement
Setting
36
37
38
l
l
33 34 35
29 30 31 32
l
l
l
l
l
l
l
l
l
l
Model code
HPR Self-regulating Pump for Open Loop Operation
4 5 6
9 10
11
12 13 14 15 16 17 18 19
20
21
Operating Speed
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
34 35
00
36
37
38
Surface Coating
Unit Identification
Eaton
Eaton Shanghai
A
B
Special Requirements
0
A
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
22
23 24 25 26 27 28
29 30 31 32
33 34 35
36
37
38
Operational parameters
Life Time Recommendations
Speed
Operating Pressure
Max. Pressure
Viscosity
Power
Purity of Fluid
Speed
Operating pressure
Viscosity
Power
Purity of fluid
1,3
1,2
1,15
1,1
1,1
0,8
1,05
1,0
ba
rA
0,9
bs
olu
te
ba
ba
ba
ba
ba
Su
cti
on
Pre
s
su
0,95
re
0,9
0,85
0,5
0,55
0,6 0,65
0,7
0,75
0,8
0,85
0,9
0,95
Operational parameters
Tank connection
Operational Parameters.
Filtration
In order to guarantee
long-term proper function
and high efficiency of the
hydraulic pumps the
Hydraulic Fluid
Recommendation
03-401-2010. Maintaining
the recommended
Commissioning
The minimum cleanliness level requirement for the
hydraulic oil is based on the most sensitive component.
For commissioning we recommend a filtration in order to
achieve the required cleanliness level.
International standard
Code Number According to ISO 4406
18/16/13
10
Operational parameters
Pressure Fluids
[C]
-20to +90
[mm/s] = [cSt]
[mm/s] = [cSt]
10to 80
15to 30
[mm/s] = [cSt]
1000
Viscosity Recommendations
Working Temperature [C]
Viscosity[mm/s] = [cSt]at 40 C
Approx. 30 to 40
Approx. 40 to 60
Approx. 60 to 80
22
32
46 or 68
Further information regarding installation can be found in the operating instructions or Eaton document 03-401-2010.
11
LSC-System
Functionality
Additonal Functionality
Machine Equipment
Benefits
Demand-oriented
pump control
Priority control of
individual actuators
Excellent precision
control characteristics
without readjustment
Output control
Customized system
design for optimum
implementation of
customer requirements
Perfect matching of
the individual operating
functions for customized
machine characteristics
Optimum utilization
of the installed power
with simultaneous
improvement of
energy consumption
Reproducibility of
machine movements
through exact control
of actuators
Dynamic response
characteristics
Load-independent,
synchronous movements
of several actuators
Social oil distribution
even in the event of
overload
Automatic venting of
directional control
valve end caps
Optimum movement
continuity even for
combined movements
12
High-pressure protection
Regeneration function
Combined function
shuttle valve
Load holding function
Optimized energy
balance for reduced
fuel consumption and
enhanced handling
performance
Modular design of
valve sections
Reduced installation
times
Optimized piping
Unsurpassed reliability
even under harsh
operating conditions
Noise reduction
SPU Silencer
In hydraulic systems
pressure pulsations can
lead to noise emission.
These pressure pulsations
are a result of the inherent
non-uniformity of the
volume flow in rotary
piston pumps.
Reduction of operating
pressure and speed. This
reduces the pulsation
energy introduced into
the hydraulic system
Secondary measures
such as vibrationoptimized design and
installation of machine
components and soundproofing for noise
suppression
Noise Generation
Primary measures
for optimizing the
compression stroke in
rotary piston machines
with the aim of reducing
pulsation
Flow Ripple
Pressure Ripple
Fluid Borne Noise
System Excitation
Noise Radiation
Noise Reduction.
SPU Silencer
All Eaton hydraulic pumps
are optimized with respect
to pulsation characteristics and therefore noise
generation.
In addition to common
primary measures such as
exclusive use of pulsationoptimized port plates,
Eaton offers the SPU
silencer for HPR open
loop pumps.
Pressure Pulsations
With and Without SPU
Conventional Commutation
Speed [rpm]
SPU Commutation
Speed [rpm]
13
Noise reduction
SPU Silencer
Reduction of pressure
pulsations over the
entire operating range
Reduction of noise
emission by approx.
50% (equals approx.
3dB(A))
Reduction of volume
flow fluctuations
Minimum increase in
weight and volume
Noise Reduction
SPU Silencer
The following diagrams
illustrate the immediate
effect of pulsation level
reduction via SPU on the
Comparison of Sound Pressure Levels for a HPR 75-02 Pump With and Without SPU
At a Speed of 2500 rpm
1000
1500
2000
2500
Speed [rpm]
50
100
w/SPU
Outside Noise
Auengerusch
Noise
Level
in
Gerusch
in 2dB(A)
Schritten
2 dB(A) steps
Conventional
marktblich
With
SPU
mit
SPU
Dieseldrehzahl
(typischer
Betriebsbereich)
Diesel
speed (typical
operating
range)
14
150
Pressure [bar]
200
250
w/SPU
Torque transmission
A) Flange Profile
Rated SizeHPR
Bolt Holt
M1 Inside Diameter
M2 Outside Diameter
M3 Bolt Hole Length
M1
M2
M3
15
Torque transmission
Mounting Flange
Dimensions K (mm)
55
75
105
135
165
210
105D
181.0
X
X
X
181.0
X
X
228.6
X
228.6
X
224.5
X
251.8
X
X
X
428.6
X
X
X
280
X
X
2-hole Flange
4-hole Flange
16
165D
Torque transmission
Drive Shaft
SAE J744
Outside
Useable
Code (for
diameter Spline
Available for Rated Size HPR
centring
Length
Shaft
and shaft)
Type 55 75 105 105D 135 165 165D 210 280
12/24, 14 t
C
16/32, 21 t
12/24, 17 t
C-C
16/32, 23 t
8/16, 13 t
D, E
16/32, 27 t
8/16, 15 t
F
31.22
34.51
37.68
37.68
43.71
44.05
50.06
30
39.5
30
38.5
50
62
58
2
1
2
1
2
1
1
X
X
X*
X X
X*
X
X
X
X
X
X
X*
X
X*
X
Outside
diameter
Outside
diamter
Excess length
Excess length
Rated Size 55
75
105
105D
135
165
165D
210
280
Excess length
mm
54 55 55 61.3
75 75 75 75 75
17
Torque transmission
B) Dimensions PTO
Rated Size
Dimensions (mm)
55
75
105
135
165
210
280
B) Dimensions PTO
18
Torque transmission
Coupling muff,
Rated size
55
75
105
X
X
X
X X X
X
X
X
X
X X X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
135
165
210
280
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
55
75
105
135
165
210
280
219
433
302
598
418
763
540
1069
659
1069
836
1655
1122
2221
Nm
Nm
19
Gear pumps
cc/rev
16
19
22.5
31
38
44
IGP
SAE A
16/32, 18 t
External
EGP
SAE A
16/32, 9 t
External
IGP
SAE A
16/32, 18 t
External
EGP
SAE A
16/32, 9 t
External
EGP
SAE A
16/32, 13 t
External
EGP
SAE A
16/32, 13 t
External
40
210
40
165
275
220
0.8 (absolut)
3.0 (absolut)
Integrated
0.8 (absolut)
3.0 (absolut)
0.8 (absolut)
3.0 (absolut)
Integrated
0.8 (absolut)
3.0 (absolut)
0.8 (absolut)
3.0 (absolut)
0.8 (absolut)
3.0 (absolut)
>> Port names clockwise rotation: A pressure port, B suction port (as shown)
>> Port names counter-clockwise rotation: A suction port, B pressure port (not shown)
>> Ports according to ISO 6149-1
>> Alternatively DIN 3852-1
>> Suction port of the IGP according to ISO 8434-1 L28
X1
LS2
LS1
X
P
MAX
20
Gear pumps
M
A
X1
LS2
LS1
P
L
MAX
External Suction
HPR
External suction
The gear pump supplies the main circuit with oil from the oil tank.
The internal connection is closed.
21
Gear pumps
SAE A
SAE B
SAE B-B
SAE C
16/32 9 t
82.55
M 10
106.4
7
-
75
107
16/32 13 t
101.6
M 12
146
11
55
175
250
16/32 15 t
101.6
M 12
146
11
55
175
250
12/24 14 t
127
M16
181
13
72
175
250
L2
L2
D2
L1
D1
D2
L1
D1
22
Type of control
Technical Data
Type of Control
Additional Option
Swashplate
Position
Feedback
Name of Regulator
Load Sensing
With Pressure Cut-off Without LP
With Power Limitation, Hyperbolic With TL2
With Electric Override
Without
E1L
Control
With Hydraulic Override
Without
H1L
Electro-proportional flow
With
LEP
limitation and pressure cut-off
Electro-proportional flow
Without
ETP
setting, power limitation
and pressure cut-off
LP-Controller
TL2-Controller
E1L-Controller
H1L-Controller
LEP-Controller
ETP-Controller
23
Type of control
Load sensing LS
Load Sensing.
Flow on Demand Control.
Pressure
To Actuator
LS-Signal
p
Orifice
L
Actual energy
requirement of
system
Vmax
Max
Regulating
Pump
LS
Volume Flow
Volume Flow
LS-Function at p = Constant
LS-Regulator
Benefits of LS-control
Any volume flow below the pump`s maximum
can be set
24
Type of control
LS
LS
P
L
MAX
Operating pressure is
maintained
No operation in the
overload range
Any operating point
under the power curve
remains accessible
Demand-oriented
volume flow generation
Possible maximum
pressure control
setting ranges
125 - 230 bar
231 - 350 bar
351 - 420 bar
LP-Regulator
LP-Characteristic Curve
Pressure
Pmax
p
Actual energy
requirement of
system
Vmax
25
Type of control
Mode-control
A mode control (mode
selection) modulates
electrically the p LS-signal
at an orifice (e.g. directional
control valve). The current
p LS value is reduced proportionally or in steps and
the pump output adjusted
via the pressure reducing
valve (see the diagrams on
following pages). In this
way the volume flow of
E1L/H1L-characteristic curve
Volume Flow
Vmax
1 - Flow
2 - Pressure
Maximum performance range of the pump
26
In principle, the p LS
value acting at the LS-pilot
can be modulated down
to zero, whereas modified
times of the pump system
should be expected in the
operating range near zero.
irrespective of ambient
influences and the number
of actuators.
Type of control
E1L. Load Sensing with electric override
M
A
X1
LS2
LS1
X
P
L
MAX
U
Pressure p LS [bar]
p LS-reduction
controller at another
HPR pump, which follows
the first pump with the
E1L controller (masterslave-operation).
E1L-controller
27
Type of control
A
LS2
LS1
D1
P1
X
P
max
H1L-controller
30
25
p LS [bar]
20
15
1
10
10
15
20
25
30
1
2
3
4
28
16 bar p setting
20 bar p setting
25 bar p setting
28 bar p setting
Type of control
Pump controllers with position feedback
2
+175
+150
+125
+105
+75
+50
+35
Z1
0
-35
-30
Z2
-75
-100
1 - Displacement
2 - Pressure
10
12
14
16
18
20
p [bar]
210
280
19 151
24 184
32 221
7.4
7.4
7.8
-3.3
-3.3 -3.4
80
80 80
250
250 250
25
25 25
29
Type of control
TL2. Load Sensing with hyperbolic power limitation
Z1
Z2
X
L
P
TL2-Characteristic Curve
Z1
Z2
Vmax
1 - Flow
2 - Pressure
Maximum performance range of the pump
30
Regulating p
Type of control
Electrical properties
12
Control types
Digital control via
Pulse Width Modulation PWM
Analogue
Connector type
Protection class
Voltage type
Power consumption
W
Rated current limiting current
mA
Relative duty cycle
%
24
E1L-controller
ETP controller
31
Type of control
2
XD
420
pmax
pmax
m= 4,3
3
Qmax
1 - Displacement volume
2 - Pressure
pXD
Flow
100 %
Qmax
100 %
RB
Control current
1 - Displacement volume
2 - Pressure
Maximum performance range of the pump
32
1
RE
Control current
12 V
24 V
464 mA
490 mA
524 mA
1200 mA
232 mA
245 mA
262 mA
600 mA
Rated size
Provided power
RB
Regulation begin
RE
Regulation end
105, 135
210
280
105 - 280
Type of control
LS
P1
XD
S1
S2
D1
X
E
P/E
P
0
max
LEP-controller
2
XD
Pmax
Qmax
1 - Flow
2 - Pressure
Maximum performance range of the pump
Regulating p
Provided power
33
Type of control
Characteristic ETP-controller
2
XD
Pmax
Z1
Z2
Qmax
1 - Displacement
2 - Pressure
34
Provided power
Dimensions
LP-controller
LS
LS
P
L
MAX
35
Dimensions
H1L-controller
A
LS2
P1
LS1
D1
X
P
36
max
Dimensions
E1L-controller
M
A
X1
LS2
LS1
X
P
L
MAX
Dimensions:
Connections:
M14x1.5
M14x1.5
LS1, 2
M14x1.5
P1
M18x1.5
37
Dimensions
TL2-controller
LS
Z1
Z2
X
38
Dimensions:
Connections:
M14x1.5
LS
M14x1.5
Z1/Z2
M14x1.5
Dimensions
LEP- controller
LS
P1
XD
S1
S2
D1
X
E
P/E
P
0
max
Dimensions:
Connections:
M14x1.5
M14x1.5
XD
M14x1.5
LS
M14x1.5
M14x1.5
M14x1.5
39
Dimensions
ETP controller
Z2
XD
Z1
40
Dimensions:
Connections:
M14x1.5
M14x1.5
XD
M14x1.5
Z1/Z2
M14x1.5
M14x1.5
Dimensions
Single pumps HPR-02 for LP, E1L, H1L
55 75 105
135
165
210
280
D
L1
L2
L3
H1
H2
B1
B2
B3
B4
Ports
Rated size
55 75 105
135
165
210
280
P
P(L)
P(H)
P(B)
T
T(L)
T(H)
T(B)
L/U
L(L)
L(H)
L(B)
U(L)
U(H)
U(B)
1
1
1
1
1
182.8 164.3 218 243.5 283.1 295 344.5
23.5 23.5 26 3. 43 27 46
91
90.5
100
107 134.5 134.5 149.5
1
1
2
2
2
3
3
189.8 201.3 227 249.5 285.6 298 344.5
94 94 103.5
120
119
149
167
21 21 25 30
0 57
57
M22x1.5 M22x1.5 M22x1.5 M27x2 M27x2 M27x2 M33x2
112.8 124.3 142
164 180.6 197.5 215.5
52 52 53 61
65
71.5
80.5
86.5 86.5 85 101.5
108 128
145
72 72 72 74.5
81.1
83
109
44 44 54 54
62
60
68
78.5 78.5 92.5 92.5
101 118
129.5
41
Dimensions
Single pumps HPR-02 for LP, E1L, H1L
View 1
42
View 2
View 3
View 4
View 5
Dimensions
Single pumps HPR-02 for TL2, LEP, ETP
-1
-2
-1
-1
-1
-2
127 125 125.4 165.1 165 224
262 272 284.5 348 403 403
301 311
323.5 387 442 442
108.9 118.5 82.8 138.5 168 168
104.5 104.5 111.5
134.5
152 152
134 134 144
144.3
200.7
238
104.5 104.5 104 135 135 144.5
194.5 194.5 214.8
266.3
314.5
314.5
208 208 256.5
269
272
272
118
116
106.7 102.4 119.5 120.2
64 64 64
64
82.5
82.5
Ports
Rated size
P
P(L)
P(H)
P(B)
T
T(L)
T(H)
T(B)
L/U
L(L)
L(H)
L(B)
U(L)
U(H)
U(B)
E*
E(L)
E(H)
E(B)
1
1
1
1
1
1
218
228
243.5 295 344.5 344.5
26 26 30
27
46
46
100 100 107
144.5
154.1
155.5
2
2
2
3
3
3
227
237
249.5 298 344.5 344.5
104 104 120
149
167
167
25 25 39.5
27
44
57
M22x1.5 M22x1.5 M22x2 M27x2 M33x2
M33x2
142
152
164 191 215.5 215.5
53 53 61
97.5
80.5
80.5
92.5 92.5 101 128 129.5
144.9
72
82
74.5 83 109 109
54 54 54
60
68
68
85 85 92
118
159.5
131.3
M14x1.5 M14x1.5 M14x1.5
M14x1.5
M14x1.5
M14x1.5
240.8 250.8 249.5 303 375 346
135.6 135.6 142.6
165.6
183.1
183.1
15 15 16
20
20
20
43
Dimensions
Single pumps HPR-02 for TL2, LEP, ETP
View 1
44
View 2
View 3
View 4
View 5
Dimensions
105D
Circuit
Flange
D1(mm)
D2(mm)
D3(mm)
B1(mm)
B2(mm)
B4(mm)
H1(mm)
H2(mm)
H3(mm)
(105:Le 165 E1L)
H4(mm)
H5(mm) port P
H6(mm) port T
H7(mm)
L1(mm)
L2(mm)
L3(mm)
L4(mm)
P (SAE)
T (SAE)
L
U
105D
105D
165D
165D
SAE 3
SAE J617a
SAE J617a
SAE J617a
147
136
162.3
116
116
170
255
80
0
260
587.6
625
50.1
310.6
2 x 1
1 x 4
M27x2
M27x2
45
Dimensions
Double pumps and plug-in pumps
H5
P1
P2
Shaft Profile W
L3
B1
B4
B2
H4
H3
SPU
H1
P2
46
H6
P1
L4, 5, 6
L1
L2
H7
D1
H2
Plug-in flange
Dimensions
Multiple pumps
Rear Pump
L1
Front Pump
L2
L3
Rear Pump
HPR 55
Front pump
HPR 55
HPR 75
HPR 105
HPR 135
HPR 165
HPR 210
HPR 280
Charge pump
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
16 cc/rev
22.5 cc/rev
22.5 cc/rev
22.5 cc/rev
38 cc/rev
38 cc/rev
38 cc/rev
488
- - - - - 548
- - - - - 602
- - - - - 500
511
- - - - 565
576
- - - - 620
631
- - - - 520
531
562
- - - 585
596
627
- - - 640
651
682
- - - 536
547
578
619
- - 596
612
643
684
- - 671
667
698
759
- - 579
591
621
679
728
-
754 766 796 854 903 -
829 841 871 929 978 -
600
612
642
701
749
751
775 787 817 876 924 926 850 862 892 951 999 1001 669
680
711
727
775
790
845
844
855 886 902 950 965 1020
919 930 961 977 1025 1040 1095
HPR 75
HPR 105
HPR 135
HPR 165
HPR 210
HPR 280
47
Dimensions
Multiple pumps
Rear Pump
Front Pump
L1
L2
L3
48
Rated Size
Rear Pump
HPR 55
Front pump
HPR 55
HPR 75
HPR 105
HPR 135
HPR 165
HPR 210
HPR 280
Charge pump
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
16 cc/rev
22.5 cc/rev
22.5 cc/rev
22.5 cc/rev
38 cc/rev
38 cc/rev
38 cc/rev
493
- - - - - 553
- - - - - 607
- - - - - 504
521
- - - - 569
586
- - - - 624
641
- - - - 525
542
567
- - - 590
607
632
- - - 645
662
687
- - - 541
558
583
623
- - 601
623
648
688
- - 676
678
703
763
- - 584
601
626
683
715
-
759 776 801 858 890 -
834 851 876 933 965 -
605
622
647
704
736
749
780 797 822 879 911 924 855 872 897 954 986 999 674
691
716
730
762
788
834
849 866 891 905 937 963 1009
924 941 966 980 1012 1038 1048
HPR 75
HPR 105
HPR 135
HPR 165
HPR 210
HPR 280
Size
Port threads
Vmax
Silencer SPU
Mounting flange
Type of control
Coupling flange
Drive shaft
Electrical voltage
Direction of rotation
Solenoid connector
PTO-direct mounting
Tandem pump
Swash speed
Drain port U + L
Surface treatment
Name plate
49
Notes
50
Notes
51
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics
2015 Eaton
All Rights Reserved
Printed in USA
Document No. E-PUPI-MC008-E3
Supersedes E-PUPI-MC008-E2
May 2015
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Group Asia Pacific
Eaton Building
No.7 Lane 280 Linhong Road
Changning District, Shanghai
200335 China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 2230 7240