Strainer: Range of Application

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Strainer

AT 4008

AT 4008

Dimension range

PN

Temperature range

Material

1/2 - 2"

16/25

-10 - 300 C

Nodular iron

Range of Application
Strainer for mechanical purification of warm, hot and cooling water, petroleum
products, saturated steam and air.

Quality Assurance
CE-marking
Fulfil PED 97/23/EC acc. to category I group 1 and 2.

Material Specification
1
2
3
4

Body, cover
Strainer basket
Gasget
Plug

nodular iron
stainless steel
graphite
brass

SIS 0717-2
SIS 2343

Dimension and Weight

DN
A
B
C
D
Plug
Height basket
Diam. basket
Weight

15

20

25

32

40

50

95
80
110
35
1/2
62
24
0,7

115
90
125
38
3/4
71
32
1,1

140
120
170
62
3/4
97
41
1,9

175
130
195
70
3/4
114
51
3,0

175
130
195
70
3/4
114
51
3,0

200
165
245
95
3/4
152
65
5,9

Measurements in mm, weight in kg.

Function and Design


Strainer with standard screen mesh size 0,6 mm which effectively separates solid
particles bigger than the mesh size when medium is passing through the cylindrical basket.

Technical Information
The chart applies to water and clean strainer with standard mesh size 0,6 mm.
To calculate pressure drop of other medium use Kv-value below.
DN

15

20

25

32

40

50

KVS

5,5

9,1

14,0

27,6

34,9

56,4

Edition 2, 2008-05-28

Sid 1 (3)

Strainer
AT 4008

Pressure drop chart

4
5
6
4
5
6

8
10

0,8
1
0,8
1

0,4
0,5
0,6
0,4
0,5
0,6

0,2

0,3

80

100

50
60

20
30
40

8
10

4
5
6

m /h

0,3

Pressure drop in bar

Pressure drop mbar

2000

1000
800
600
500
400
300
200

DN
100

0
15
0 DN
5
12
DN 00
1
DN

20

80

80
DN 5
6
DN

60
50
40
30

DN

20

10

DN

DN

40

DN

DN

DN

DN

50
32

25
20
15
10

1
0,8
0,6
0,5
0,4
0,3

8
10

0,2

100

80

50
60

20
30
40

8
10

4
5
6

0,1

0,2

Pressure drop in bar

Pressure drop mbar

Pressure and temperature


Working pressure

Working temperature

Fig. no.

DN.

max. bar(e)

min C

max C

AT 4008

DN 15-50

25
20
16

-10
-10
-10

120
200
300

Accessories and Options


On request the strainer can be provided with:
Screen 0.1, 0.25, 0.35, 0.5, 1,0, 1.5, 2.0, 2.5, 3.0, 5.0 and 8.0 mm.
Permanent magnet AT 4008P which effectively separates magnetises.
Blow-out valve AT 3591.
For installation in cooling system the strainer are available with external rust preventing according to system AT 1012.

Installation
For best function and easiest cleaning the strainer should be mounted in a hori-

Edition 2, 2008-05-28
Sid 2 (3)

Strainer
AT 4008
zontal pipe with the plug downwards and flow direction according to flow arrow.
Drain-valve can replace the plug to flush the strainer.

Maintenance and Spare parts


Substantial increasing pressure drop indicates that the strainer should be flushed
clean.
Strainer basket and gasket are available as spare parts.

Marking
Manufacturer, DN, PN, material and flow arrow.

How to order
Example: AT 4008-50
Fig. no.

DN / internal thread

Art. no.

AT 4008

15 /
20 /
25 /
32 /
40 /
50 /

4008-15
4008-20
4008-25
4008-32
4008-40
4008-50

1/2
3/4
1
1 1/4
1 1/2
2

Edition 2, 2008-05-28