Mrs. Lazatin 2 Model
Mrs. Lazatin 2 Model
TIE BARS
(TYPICAL)
L1/4
As
L2/4
Cs
BL
L2/4
Ds
BL
19 CLR.
(TYP'L.)
19 CLR.
(TYP'L.)
GENERAL NOTES
19 CLR.
(TYP'L.)
Bs
1. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE FOLOWING: a. ACI 316-89
b. AISC 1984 c. NSCP 1992 d. UBC 1994
Bs
50
50
50
EXTERIOR
BEAM SUPPORT
2. IN THE INTERPRETATION OF THE DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN AND THE DISTANCES
OR SIZES ARE NOT TO BE SCALED FOR CONSTRUCTION PURPOSES.
Lx/4
50
50
FIRST INTERIOR
BEAM SUPPORT
SECOND INTERIOR
BEAM SUPPORT
3. FOR ALL OTHER REQUIREMENTS, REFER TO ARCHITECTURAL, SANITARY, ELECTRICAL, AND MECHANICAL
WORKING DRAWINGS.
ONE-WAY SLAB
L3/4
4. ALL CONCRETE MUST BE DEPOSITED, VIBRATED, AND CURED IN ACCORDANCE WITH ACI STANDARDS.
COLUMN NOTES
TIE BARS
(TYPICAL)
EL
L4/4
Lx/4
EL
19 CLR.
(TYP'L.)
L4/4
19 CLR.
(TYP'L.)
REGION.
FOOTING NOTES
19 CLR.
(TYP'L.)
Fs
50
Es
Fs
1. FOOTINGS ARE DESIGNED FOR ALLOWABLE SOIL PRESSURE AS PER INVESTIGATION REPORT. CONTRACTOR
SHALL REPORT TO THE STRUCTURAL ENGINEER ANY INDICATION OF SOFT SOIL CONDITION. (AT 1500MM DEPTH
FROM NATURAL GRADE, qa = 3000 PSF)
Fs
50
L3/5
50
L3/5
EXTERIOR
BEAM SUPPORT
ES
Fs
L4/5
FIRST INTERIOR
BEAM SUPPORT
SPAN L2 (INTERIOR SPAN)
50
50
L4/5
Lx/5
SECOND INTERIOR
BEAM SUPPORT
TWO-WAY SLAB
3. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 76MM CLEAR FOR CONCRETE
DEPOSITED AGAINST THE GROUND AND 51MM CLEAR FOR CONCRETE DEPOSITED AGAINST THE FRAMEWORK.
L1/4
CONCRETE SLAB
L1/4
L2/4
L2/4
L3/4
SECOND INTERIOR
BEAM SUPPORT
FIRST INTERIOR
BEAM SUPPORT
L4/4
L4/4
SECOND INTERIOR
BEAM SUPPORT
FIRST INTERIOR
BEAM SUPPORT
L7/4
As
Cs
FIRST INTERIOR
BEAM SUPPORT
Ds
SPAN L/6
CENTER EACH WAY AT CENTER OF SLAB. CONSTRUCTION JOINT FOR SLAB SHALL NOT BE MORE THAN 3000MM
APART.
BL
L 1/4
L 2/4
Fs
EXTERIOR
BEAM
SUPPORT
Bs
EXTERIOR
BEAM
SUPPORT
Bs
SPAN L2
L 2/6
L1
EL
EL
L3/5
L3/5
L4/5
SPAN L3
L4/5
SPAN L4
TWO-WAY SLAB
25MM CLEAR
DISTANCE
(MINIMUM)
L 1/6
Es
Fs
AL
SPAN L1
L 1/6
Es
L 2/4
X
CANTILEVER BEAM
FL
L6/5
L5/4
(1.0 MAX.)
BL
L 1/4
L7/5
L6/4
SPAN L5
4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE TENSION FACE AND SHALL NOT BE
LESS THAN 0.025BT.
L7/4
FL
L6/5
3. UNLESS OTHERWISE SHOWN IN DETAIL FOR SLABS, THE REINFORCING BARS SHALL BE BENDED, EXTENDED,
OR CUT AS FOLLOWS:
CL
SPAN L/7
L5/4
(1.0 MAX.)
2. FOR TWO-WAY SLAB ALONG THE LONGER SLAB SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN
AT CENTER AND OVER THE LONGER SPAN BARS NEAR THE SUPPORT UNLESS OTHERWISE INDICATED OR
SHOWN IN DETAILS. THE SPACING OF THE BARS AT THE COLUMN STRIPS CAN BE APPROXIMATELY 1 31 OF THE
MIDDLE STRIP IN NO CASE GREATER THAN 2 31 TIMES THE SLAB THICKNESS.
L7/5
1. ALL REINFORCEMENT SHALL BE 19MM CLEAR FROM TOP & BOTTOM OF SLAB.
SCALE
NTS
L 2/6
L2
37.7MM CLEAR
DISTANCE (MINIMUM)
FOR BEAMS & GIRDERS
NTS
37.7MM CLEAR DISTANCE FOR BEAMS & GIRDERS.
DESIGNER:
CERTIFIED BY :
W O O D Y A. D A V I D
ARCHITECT
Cel No.:09086168144
Email ad.:donwudz @ yahoo.com
UAP
CIVIL ENGINEER
PRC NO.
TIN
PTR NO.
DATE
PLACE
PROJECT TITLE :
OWNER :
LOCATION :
OWNER'S APPROVAL
SHEET CONTENTS :
AS SHOWN ABOVE
SHEET NUMBER :
S-3