Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

10/27/2016

ElectricalTestandMeasurementEquipment

ICEwebhasnearly100Control,Instrumentation,Fire&Gas,Safety
InstrumentedSystemscorepagesandatotalofmorethan300pages
ItReallyisCoolEngineeringByEngineersforEngineersitmust
bejustabouttheWorld'sfirstchoiceforTechnicalInformation.
Whilsteveryeffortismadetoensuretechnicalaccuracyoftheinformationsuppliedoniceweb.com.au,KeyfleetPty
Ltdanditsemployeesacceptnoliabilityforanylossordamagecausedbyerrororomissionfromthedatasupplied.
Usersshouldmakeandrelyontheirownindependentinquiries.Byaccessingthesiteusersacceptthiscondition.
Shouldyounoteanyerror/omissionoranarticleoffendspleasedonotignoreit,contactthewebmasterandwewill
review,rectifyandremoveasnecessary.
ThefollowingreferencesarefromsourceswhichprovidewhatICEwebconsiderstobethebesttechnicalandeducational
informationonthesubject.Wealwaysacknowledgetheauthorandsource.ShouldtherebeanyissuewithICEwebproviding
thisinformation,pleasecontactusandwewillremoveitimmediately.Wealsowelcomenoncommercialtechnicaldocuments
(subjecttoeditorialreview)andpostthemfree.
Like Bethefirstofyourfriendstolikethis.

ElectricalTestandMeasurementEquipment
ZedfloAustraliaisaWesternAustraliancompanyestablishedin
1982.Theyareproudoftheexcellentreputationandstrong
relationshipsthathavedevelopedwithindustryoverthelast20
yearsandcontinuetostrivetobuildnewrelationships.Zedflo
suppliesacomprehensiverangeofprocesscontrolfield
instrumentation,test&calibrationequipmentandnonintrusive
ultrasonicflowmetering,providingsolutionstotheoil,gas,
process,miningandchemicalindustries.
GotoSpecificSubject:ElectricalInstallationSafetyTestingusingTestandMeasurementEquipment|Electrical
InsulationTesters|ElectricalInsulationTesting|TestingofResidualCurrentDevices|LowVoltageElectrical
InstallationsSafetyandMeasurementsinPractice|OtherUsefulElectricalTestandMeasurementInformation|
ElectricalLowResistanceTesting|ElectricalSafety|InspectionandTestingofElectricalEquipment|SelfTraining
ManualforElectricalMeasuringEquipment|UseofElectricalTestEquipment|ICEweb'sElectricalTechnical
InformationSection|
ThefollowingTechnicalInformationisprovidedbyoursponsorZedfloAustralia,theyareexpertsinElectricalTestand
MeasurementEquipment.Shouldyouhaveanyquestionsorrequirefurtherinformationyoucancontactthemhere.

ElectricalTestandMeasurementEquipmentisanessentialpartofanyElectrician'stoolkit.With
today'stechnologicaladvanceshighqualityelectricaltestandmeasurementtoolsarerequired.By
purchasinghighlyspecifiedequipmentonecanbeassuredofsafety,accuracyandrobustnessalong
withuserinterfaceswhichmakethemmoreuserfriendly.Theequipmentisusedtotestandverify
safetyandoperatingparametersofElectricalEquipment.TypicalElectricalTestandMeasurement
EquipmenttestsInsulationresistance,Continuityofprotectiveconductorsandequipotentialbonding,
ResidualCurrentDevices,LineImpedance,FaultLoopImpedance,EarthResistance,Phase
Sequence,VoltageandFrequency,PETestTerminal,OvervoltageCategory,HV,Step/ContactVoltage
andEarthResistance.

ElectricalInstallationSafetyTestingusingTestandMeasurementEquipment
ElectricalInstallationSafetyTipsThisisasuperelectricalinstallationsafetyinformationresourcewhichcoversElectrical
InstallationSafetyTesting,testingsafetyofelectricalinstallations,Insulationresistance,Continuityofprotectiveconductors
http://www.iceweb.com.au/Electrical%20Test%20and%20Measurement/Electrical%20Test%20and%20Measurement.htm

1/4

10/27/2016

ElectricalTestandMeasurementEquipment

andequipotentialbonding,RCDtesting,Lineimpedance,Faultloopimpedance,Earthresistance,Phasesequence,voltageand
frequency,PEtestterminal,Overvoltagecategory,HV,Step/ContactVoltageandEarthResistance,Basicsofinsulation
measurements,Typesofinsulationtesting,Testingsafetyofelectricalequipment,Testingthesafetyofmachinesand
switchboards,PowerQualityTesting,LANCablingCertification,IndoorEnvironmentQuality,Multimeter/Clamp/Voltageand
ContinuityTesters.
GuidetoTestingandTaggingPortableElectricalEquipmentandResidualCurrentDevicesatWorkplacesAs
prescribedbytheOccupationalSafetyandHealthRegulations1996(theOSHregulations),thepersonhavingcontrolofa
workplaceoraccesstothatworkplace,i.e.Employer,selfemployedperson,maincontractor,mustensurethatallportable
pluginelectricalequipmentandresidualcurrentdevices(RCDs)attheworkplacearesafeandappropriatelyinspected,tested
andmaintainedbyacompetentperson.Thisdocumentwillassistwithregulatorycompliancebyprovidingguidanceonwho
caninspectand/ortestandtagsuchportableequipmentanddevicesfromWorksafeWA.

ElectricalInsulationTesters
ElectricalInsulationTestersPeterGabrovekThisWhitePapercoversDangersfortheElectrician,HowTransientsand
SurgesOccur,HowHighEnergybreakdownstakePlace,WhyaBreakdownattheOriginofInstallationcanhaveMoreSevere
Ramifications,HowtheStandardsDealwithOvervoltages,OvervoltageProtectionCategoriesasDefinedinIEC/EN60364,
OvervoltageCategoriesandElectricalInstallationTesters,ProtectiveMeasuresinInstallationTesters,OtherSafety
Considerations,CommonMisinterpretationoftheOvervoltageProtectionClasses.

ElectricalInsulationTesting
GuidetoModernInsulationTestingManualTheintentionofthis48pagehandbookistobetteracquaintthereaderwith
theextensiveproblemsassociatedwithinsulationmeasurements.Themanualcovers
Thebasicsofinsulationmeasurementandtermsthatareregulatingthisfield.Specialattentionisgiventotermsand
definitionsthatusersofmeasuringequipmentmeetdaily.
Typesofinsulationtesting.
Typicalproblemsduringinsulationmeasurement.
Importantconnectionsfortestinginsulationresistance.Thecompletesequenceisshown,fromtheperceptionofthe
problem,preparationandmeasurement,alongwithanalysisandresults.

TestingofResidualCurrentDevices
TestingofResidualCurrentDevices(RCD)BtypeRCDthisWhitepaperdetailsthebasicsaboutRCD's,Producersof
RCD's,InternationalReferenceStandardsforRCD's,TestingofBtypeRCDsandTestInstruments.

LowVoltageElectricalInstallationsSafetyandMeasurementsinPractice
ShortTheoryaboutTheSafetyandMeasurementsinPracticeonLowVoltageElectricalInstallationsJanezGuzelj
ThiswhitepapercoverstheTNSystem,TTSystem,EnsuringSafetyalongwithActualPracticeoftheMeasurementsonthe
ElectricalInstallation.
MeasurementsonElectricInstallationsinTheoryandPracticeInstructionManualThismanualisdesignedfor
electricalengineerswhodealwithmeasurementsonnewormodifiedlowvoltageelectricalinstallationsinbuildingsorwith
themaintenanceoftheseinstallations.Inthemanualtheusercanfindanexplanationformanypracticalproblemswhilst
performingmeasurementsanddirectionsonhowtosolvetheproblemsbyusingthemeasurementinstrumentsproducedby
METRELd.d.

OtherUsefulElectricalTestandMeasurementInformation
http://www.iceweb.com.au/Electrical%20Test%20and%20Measurement/Electrical%20Test%20and%20Measurement.htm

2/4

10/27/2016

ElectricalTestandMeasurementEquipment

MeasuringInstrumentsandTestersThisTechnicalCataloguecoversElectricalInstallationSafety,HighVoltage
Insulation/Continuity/Earth,Appliance/Machine/SwitchboardSafety,PowerQualityAnalysis,LANCabling
Certification,IndoorEnvironmentQuality,DigitalMultimeters/ClampMeters/VoltageandContinuityTesters,Variable
transformers/EquipmentforlaboratoriesandSchoolsfromMETREL

ElectricalLowResistanceTesting
AGuidetoLowResistanceTestingUnderstandingandMeasuringLowResistancetoEnsureElectricalSystem
PerformanceThepurposeofthisbookletistohelptheengineer,technicianoroperatorunderstand:
Therationalebehindlowresistancetesting.
Howtomakealowresistancemeasurement.
Howtoselecttheproperinstrumentforthetestingapplication.
Howtointerpretandusetheresults.
ThankstoTechrentals

ElectricalSafety
ManagingElectricalRisksinTheWorkplaceCodeofPracticeThisCodeprovidespracticalguidanceforpersons
conductingabusinessorundertakingonmanagingelectricalrisksintheworkplace.Itappliestoallworkplaceswhereaperson
conductingabusinessorundertakinghasmanagementorcontrolofelectricalequipment,includingelectricalinstallations,or
carriesoutelectricalworkonornearenergisedelectricalequipment,includingelectricalinstallationsfromSafework
Australia.
DepartmentofEnergyHandbookonElectricalSafetyTheElectricalSafetyHandbookpresentstheDepartmentof
Energy(DOE)safetystandardsforDOEfieldofficesorfacilitiesinvolvedintheuseofelectricalenergy.Ithasbeenprepared
toprovideauniformsetofelectricalsafetyguidanceandinformationforDOEinstallationstoeffectareductionorelimination
ofrisksassociatedwiththeuseofelectricalenergy.Theobjectivesofthishandbookaretoenhanceelectricalsafetyawareness
andmitigateelectricalhazardstoemployees,thepublic,andtheenvironment.Ithasasectiononworkingwithtestinstruments
andequipment.
AReviewofCommonElectricalSafetyTestRequirementsDwayneMDavisFourTestsarecommonlyusedtoverify
electricalsafety,theyareLineLeakage,InsulationResistance,GroundBondingandDielectricwithstandtesting.Thiswhite
paperdetailseachofthesetestsfromassociatedresearch.
ElectricalSafetyTestingReferenceGuideThisdocumentfromthePowerSourcesManufacturersAssociationisauseful
informationsource.ItexplainstheneedforandthebasisforElectricalSafetyTesting.
ElectricalTestEquipmentforUsebyElectriciansThisdocumentgivesguidancetoelectricallycompetentpeopleinvolved
inelectricaltesting,diagnosisandrepair.Electricallycompetentpeoplemayincludeelectricians,electricalcontractors,test
supervisors,technicians,managersorappliancerepairers.Itoffersadviceintheselectionanduseoftestprobes,leads,lamps,
voltageindicatingdevicesandmeasuringequipmentforcircuitswithratedvoltagesnotexceeding650VfromtheHSE(UK).

InspectionandTestingofElectricalEquipment
TestingManualforElectricalEquipmentNahedAlHajeriandAnanthaMadhavanThepurposeofthistestingmanualis
toprovideguidelinesforinspectionandtestingofElectricalEquipmentincompliancetorelevantinternational
standards/specifications.ItprovidesinformationonproceduresandtestingofMajorElectricalequipmenttobefollowedduring
testingbyengineersandalsofurnishevidencethatanelectricalequipment/deviceisfreeofinherentflawsorfaults.Thetests
onequipment/systemhavebeenbroadlycategorizedintotwocategoriesviz.FactoryAcceptanceTest(FAT)andSite
AcceptanceTests(SAT).Thesetestshavebeentailoredtoensuredesign,constructionandperformancerequirementsofthe
equipment.ThistestingmanualincludesHighVoltageSwitchboards,LowVoltageSwitchboards,Transformer,Diesel
GeneratorSets,InductionMotors,Cables,UninterruptedPowerSupply(UPS),RingMainUnit,LightFittings,MOV
Actuators,IsolatorSwitchandEarthingSystemsetc.HoweverinthisPaperonlyhighlightsthehighvoltagecablesandrelated
testmethodsfromEPPM.
http://www.iceweb.com.au/Electrical%20Test%20and%20Measurement/Electrical%20Test%20and%20Measurement.htm

3/4

10/27/2016

ElectricalTestandMeasurementEquipment

SelfTrainingManualforElectricalMeasuringEquipment
IntroductiontoTestEquipmentThis272pageTrainingModulefromtheUSNavyisanintroductiontosomeofthemore
commonlyusedtestequipmentandtheirapplications.WhilstdesignedforNavaluseitisaveryusefulselftrainingtool.

UseofElectricalTestEquipment
UseofElectricalTestEquipmentTestequipmentisnecessaryfordeterminingpropersetup,adjustment,operation,and
maintenanceofelectricalsystemsandcontrolpanels.ThefollowingisageneralprocedureforuseoftestequipmentfromUS
ForestService.

ICEweb'sElectricalTechnicalInformationSection
Basicsof
Electricity

Cable
Tray

Cables

Electrical
Motors

Hazardous
Areas

High
Voltage

Uninterruptible Variable
Power
Speed
Supplies
Drives

Circuit
Documentation
Protection
Earthing

Electrical
Wiring

Lightning&
Surge
Protection

PLC

Lighting

MCC's

Electrical
Safety

Enclosures

Suppliers Terminations

Windfarm
Turbines

http://www.iceweb.com.au/Electrical%20Test%20and%20Measurement/Electrical%20Test%20and%20Measurement.htm

4/4

You might also like