Cold Working and Electrical Conductivity
Electrical Conductivity
[(V-m)21]
6.8
6.0
4.3
3.8
1.6
1.0
0.94
0.6
0.2
3
3
3
3
3
3
3
3
3
107
107
107
107
107
107
107
107
107
400
300
100
+100
Cu + 3.32 at% Ni
5
Electrical resistivity (108 m)
200
Cu + 2.16 at% Ni
Deformed
Cu + 1.12 at% Ni
2
i
"Pure" copper
t
250
200
150
100
50
+50
Temperature (C)
Matthiessens rule
for a metal, total
electrical resistivity
equals the sum of
thermal, impurity,
and deformation
contributions
Matthiessens rule
mechanisms act independently of one another. This may be represented in mathematical form as follows:
rtotal 5 rt 1 ri 1 rd
(18.9)
in which rt, ri, and rd represent the individual thermal, impurity, and deformation
resistivity contributions, respectively. Equation 18.9 is sometimes known as
Matthiessens rule. The influence of each r variable on the total resistivity is demonstrated in Figure 18.8, a plot of resistivity versus temperature for copper and several coppernickel alloys in annealed and deformed states. The additive nature of
the individual resistivity contributions is demonstrated at 21008C.
Influence of Temperature
For the pure metal and all the coppernickel alloys shown in Figure 18.8, the resistivity rises linearly with temperature above about 22008C. Thus,
Dependence of
thermal resistivity
contribution on
temperature
Impurity resistivity
contribution (for
solid solution)
dependence on
impurity
concentration
(atom fraction)
rt 5 r0 1 aT
(18.10)
where r0 and a are constants for each particular metal. This dependence of the thermal resistivity component on temperature is due to the increase with temperature
in thermal vibrations and other lattice irregularities (e.g., vacancies), which serve as
electron-scattering centers.
Influence of Impurities
For additions of a single impurity that forms a solid solution, the impurity resistivity ri is related to the impurity concentration ci in terms of the atom fraction
(at%y100) as follows:
ri 5 Aci 11 2 ci 2
(18.11)
m)
50
40
30
20
10
10
20
30
40
50
where A is a composition-independent constant that is a function of both the impurity and host metals. The influence of nickel impurity additions on the roomtemperature resistivity of copper is demonstrated in Figure 18.9, up to 50 wt% Ni;
over this composition range nickel is completely soluble in copper (Figure 9.3a).
Again, nickel atoms in copper act as scattering centers, and increasing the concentration of nickel in copper results in an enhancement of resistivity.
For a two-phase alloy consisting of a and b phases, a rule-of-mixtures expression
may be utilized to approximate the resistivity as follows:
Impurity resistivity
contribution (for
two-phase alloy)
dependence on
volume fractions and
resistivities of two
phases
ri 5 raVa 1 rbVb
(18.12)
where the Vs and rs represent volume fractions and individual resistivities for the
respective phases.