Professional Documents
Culture Documents
Global Chimney and Exhaust Solutions Global Chimney and Exhaust Solutions
Global Chimney and Exhaust Solutions Global Chimney and Exhaust Solutions
GLOBAL CHIMNEY
AND EXHAUST
CHIMNEY
AND EXHAUST
SOLUTIONS
SOLUTIONS
designmanufactureinstallationmaintenance
POUJOULAT
GROUP: GLOBAL
SUPPLIER OF ALL
METAL CHIMNEY
SOLUTIONS
A Turnkey - DESIGN,
MANUFACTURE & BUILD
service, with maintenance!
DESIGN
Our engineering teams carry out structural, acoustic and thermal
calculations and expert Assessments, to provide the best value
engineered solution.
MANUFACTURING
All products are manufactured within Poujoulat Factories to the
highest quality respecting relevant standards, the environment
and promoting safety. Manual welding operations are certied
to EN 287-1 and EN 1418 for fully mechanized and automated
welding processes and our all welding procedures are accredited
and tested to EN ISO 15614-1.
INSTALLATION
Our installers are specically trained to the highest level in the
necessary skills and competencies to complete the most
complex installations, providing a quality nish, in the safest
manner, throughout Europe.
MAINTENANCE
We carry out maintenance programs designed to minimise
operational interference and maximise the life cycle and security
of the chimney and plant.
Our detailed expertise extends to the maintenance of concrete,
brick and metal Industrial chimneys.
For more information, please contact your local Poujoulat Project Manager.
Wood
Solid Fuel
Gas
Oil
POUJOULAT CHIMNEYS:
YOUR BEST CHOICE!
X
OPTIMIZATION
The Performance, Mechanical Stability and Structural properties, and the Thermal and
uid dynamic design of our chimneys, ue sections and raw materials are compliant to
EN 13084 or EN 13384, ensuring the best material and section optimization for your
project.
LIFETIME
Modular system chimney are manufactured and CE marked to EN 1856
and installed to EN 15287 and come with an AXA backed 10-year guarantee.
Self-supporting steel chimneys are designed according EURO CODES EN 1993-3-2.
Specifying the requirements for resistance (strength, stability and fatigue) of steel
chimneys; dening the life cycle and required maintenance of the chimney.
INTEGRATION
We provide a complete Turnkey Package, Design, Manufacture, Installation and
Maintenance that will fully integrate into the build and whole life cycle needs of your
project, with our knowledge and expertise always there to provide guidance.
ASSISTANCE
By your side our experienced project managers and engineers follow each step of the
project from conception to commissioning and handover.
PARTNERSHIP
As a global partner, our activity aims to contribute to your success achieving your
customers satisfaction, with the philosophy of a long term partnership.
X
EXPERIENCE
GROUP SOLIDITY
THE CE-MARKING
Since 2008, all Poujoulat Chimney Systems are CE-marked to European regulations.
The CE-marking on modular and free standing chimneys identifies clearly the correct
information regarding the performance of the products.
The compliance of our chimneys with these European standards (CE) guarantees the
mechanical resistance, the stability, the security and energy savings.
A S O L U T I O N F O R A L L A P P L I C AT I O N S A N D F U E L S
DOUBLE-CHAMBER RESONATOR
for boilers
Silencers for boilers, are designed to reduce low frequency noises
generated by the combustion process and then transmitted via
the ue.
Diesel generators
Dynamic
vibration
damper
Expansion
chamber
Perfectly watertight
partition welded
to the inner wall of
the silencer
BEIRENS
free-standing,
self-supporting
multi-ue
chimney
Connecting pipe
BAFFLES SILENCER
for fans and for turbines*
Silencers for fans reduce medium and high frequency sounds
generated by the high speed ow of gases circulating in the duct,
exhausts or chimney.
BEIRENS
free-standing
ChemInnov
chimney
Condensor
single wall ue
Bafes
Outer jacket
Mineral wool
Insulation
Therminox
insulated ue
BEIRENS
free-standing,
self-supporting
double wall
chimney
Absorptive
bulb silencer
Implosion
and explosion
protection
Insulated ue
Therm GEP 50
Pressure
resistance H1
Box frame
*note: turbines require specic and dedicated design
DOUBLE-CHAMBER RESONATOR,
ABSORBENT WALL BULB
SILENCER (REACTIVE SILENCER)
Silencer
Silencer
BEIRENS
free-standing,
single wall chimney
Cascade System
Leading cone
Non-return valve
Perforated plate
Expansion
chamber
Fibreglass
CONDENSOR
THERMINOX - CONDENSOR
THERMINOX
THERM+ GEP
CHEMINNOV
SINGLE-FLUE CHIMNEYS
High quality, stainless steel, twin wall, preinsulated exhaust system for engines.
POUJOULAT GROUP
AND BEIRENS WORLDWIDE
BUREAU VERITAS
Certification
ISO 9001
POUJOULAT BV
Ettensestraat 60 NL - 7061 AC TERBORG
Tel.: 0315-340050 Fax: 0315-340150
www.poujoulat.nl info@poujoulatbv.nl
Some photographs in this brochure have been created for indicative illustration purposes only and
may not represent actual installation requirements. This brochure is copyright 2013 and may not be
reproduced in any part or form without prior written consent from Poujoulat Belux SA and poujoulat BV.
FM 559916