Splice Detail for Air Cooler C-856
Check Geometric Properties
Properties of Air Cooler Column
W8X31 (Please see attached sketch)
2
A= #REF!
in , Total Cross Sectional Area
d= #REF!
in, total depth
bf= #REF!
in, flange width
tf= #REF!
in, flange thickness
Af= #REF!
in2, flange area
tw= #REF!
in, web thickness
Aw= #REF!
in2, web area
Ix= #REF!
in4, strong axis moment of inertia
Sx= #REF!
in3, strong axis section modulus
Iy= #REF!
in4, weak axis moment of inertia
Sy= #REF!
in3, weak axis section modulus for plates
*-9-*-9
Flange Splice Plates
w= 200.00
mm, plate width
t= 16.00
mm, plate thickness
db= 21.00
mm, bolt hole dia
An1= 2528.00
mm2, net area, w(t-(2 x db))
An1= 3.92
in2, net area per flange plate
An1>Af OK
Ipx= 185.00
in4, strong axis moment of inertia
Spx= 39.96
in3, strong axis section modulus for plates
Spx>Sx OK
Ipy= 51.25
in4, weak axis moment of inertia
Spy= 13.02
in3, weak axis section modulus for plates
Spy>Sy OK
Check Bolt Capacities
Use 3/4 " dia A490 bolts Type X Connectiion, Min tensile stress Fu=150 ksi
Bolt Shear
Fv= 17.70
Sa= 21.60
Ta= 84.64
fv= 14.11
Fv>fv OK
Plate Bearing
d= 0.75
t= 0.44
Fp= 22.71
fp= 14.11
Fp>fp, OK
kips, allowable bolt load in shear, per Table 1-D, AISC ASD Ninth ED
ksi, allowable stress in tension = 0.6Fy
kips, allowable tensionload on each plate.
kips,developed shear load per bolt, Ta/6 (number bolts=6)
file:///var/www/apps/conversion/tmp/scratch_4/335325614.xls
CALCULATION NOTES
Project: Petrox Hydrogen Plant # 2
Document # 31032-000-1835-100 Rev 0
SUBJECT:
Splice Detail for C-856
By:
Date:
SA
6/8/04
Ckd
JL
Date:
6/8/04
Page:6/6
file:///var/www/apps/conversion/tmp/scratch_4/335325614.xls