Flow Rate and Valve Sizing
Flow Rate and Valve Sizing
In order to design valves for a process system correctly, the valve size is determined by the required flow rate.
The Kv-value serves as a calculation basis for the different process conditions.
This value is stated in the following table with regard to nominal diameter and standards.
Conversion:
For the correct Kv to Cv conversion calculation, use only
the stated units formulas below.
The Kv-value must be converted from (cubic meter / hour)
by utilising the following conversion factors.
In the US the flow rate of water is measured with the
Cv-value in US-gallons per minute (gpm) with a pressure
drop of p 1 PSI.
Conversion of Kv in Cv
Cv = 1,17 x Kv
Conversion of Cv in Kv
Kv = 0,86 x Cv
Test stand to determine and document flowrates and Kv (Cv) values
Kv-value
The Kv-value is a parameter defining the flow rate of
valves. It describes the amount of water from 5 to 30C
which flows through the valve at a pressure loss of 1 bar.
The Kvs-value describes the Kv-value when the valve is
100% open.
For water 5-30C applies:
Explanations:
Kv m3/h
Q m3/h
kg/m3
p1
bar
p2
bar
p
bar
Aseptic valve Kv
Valve type
188/195/307/
289/295/397
NPS
4
6
8
10
15
8
10
15
20
15
20
25
32
40
50
65
1/4
3/8
1/2
1/4
3/8
1/2
3/4
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
8
8
8
8
8
10
10
10
10
25
25
25
40
40
50
80
Nominal diameter
ISO 1127 DIN 11850 ASME-BPE
2,4
2,7
3,9
5,3
10,5
13,0
15,5
43,0
50,0
64,0
95,0
2,3
2,5
4,7
5,5
9,5
11,5
14,2
43,0
52,0
89,0
0,7
1,4
2,0
1,4
2,2
4,6
6,8
12,0
40,0
48,0
85,0
01294GB-2013/R02
385/402/407/ 495/
985/995/997
DN
MA
size
www.asconumatics.eu
99