Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 6

Foundation Calculation for Refrigerant Surge Tanks, V-503-001A/B/C

Fill in only yellow cells


Do not unprotect the sheets
Mahshahr Facilities
BB2C
V-503-001ABC, Rev.0b

PROJECT NO.:
CLIENT:
VESSEL NO.:

BY:
CHECKED:
DATE:

TCR
DGV
4/26/2010

All dimensions in kN and meters (UON)


H.P.P.=
0.98
1. Geometrical data:

Pier:

C1=
C2=
C3=
L1=
L2dry=
L2wet=
L4=
L5=
TOG =
C0=

Overall diameter (OD + insulation)


1.375
H1=
3.86
0.000
H2=
0.000
H3=
7.300
3.650 (by default assume 0.5*L1)
3.650 (by default assume 0.5*L1)
1.214
1.214
2.480
2.200 Pw=
2.600 Pt=

D1=
D2=
D3=

2.706
0.000
0.000

L3dry=
L3wet=

3.650
3.650

0.400

2. Vertical load
Equip.
Id.
C
B
A

Weights
Dry
0.00
0.00
275.00

Wet
Bundle
0.00
0.00
0.00
0.00
456.00
0.00

Loads at saddles elevation


Add (10- Erection Weight Operating Weight
20%)
Pe1
Pe2
Po1
Po2
Operatin
sliding
fixed
sliding
fixed
g
1.00
1.00
1.20 165.0
165.0
273.6
273.6

3. Wind load

(INBC Part 6, Loading, Wind Loads)

basic wind speed V (km/h)


q (kN/m2)=0.005*V2
Ce

162.00
1.31

Cq (round tanks)

0.8

Cq (square/rectangular)

1.4

INBC-6-6-3
INBC-6-6-9-1

Formulas
P=Ce*Cq*q (kN/m2)
Ae =De*h (m2)
F=P*Ae (kN)
Effective diameter, De = Overall OD x Area Increase Factor

Overall Diameter
D0 900mm

Area Increase Factor

(C & S Design Criteria, Secn.4.4)

1.50

901mm D0 1400mm

1.40

1401mm D0 2000mm

1.30

2001mm D0 2600mm

1.20

2600mm < D0
De =
3.193

1.18
Loads at equip. elevations and center lines
Transversal
Longitudinal

Equip.
Id.

zi (m)

C
B
A
Pier

2.88
0.75

Ce INBC p=CeCq q(kN/m2)


6-6-6-1
INBC-6-6-5

2.00
2.00

2.10
3.67

Ftr (kN)

Flg (kN)

65.2
7.3

16.8
7.2

Transversal
Equip.
Id.

Distanc Distanc
Ftr1
e C.L. to e C.L. to
sliding
sliding
fixed

C
B
A
3.65
3.65
Pier
Loads at saddles

Ftr2
fixed

32.6
3.6
36.3

32.6
3.6
36.3

Longitudinal
Mtr1
sliding

Mtr2
fixed

44.8

44.8

44.8

44.8

Flg 1&2
sliding
& fixed

Pax1
sliding

11.99

7.36

Pax2
fixed

-7.36

4. Thermal load

1.10E-05

m/m/C

Tinlet=
61.1 C
Toutlet=
0
(m)= * L1 * (Tavg - 20 ) =
Ff=3 * Ec * Ip * / C03 /2=
where: Ec=
Ip = Pw * Pt3 /12=
Ft (min(0.3*Po1, Ff))=

mild steel
stainless steel
Tavg=
61.1 C

82.08 (expansion - opposite signs on piers!)


(Iranian Code STD. No. 2800, 3rd Edition)

5. Seismic load, V
Seismic coefficients:
Design base acceleration, A
Soil profile classification,
Seismic parameter S
Seismic parameter T0

1.10E-05
1.60E-05
61.1 C
0.003
159.88
24800 mPa
0.014

0.2
IV
2.25
0.15

Seismic parameter Ts
Building importance factor (high), I
Non-building behavior factor, R
T, sec =
B=
B/R=
C=
V=

1
1.2
3

0.11
2.66
0.89
0.000
0.00

(2-7)
(2-3)
(2-14-1c and d)
(2-1)

Transversal

Vsliding, kN= V*L2/ L1=


Msliding, kNm=Vsliding*C1=

0.00
0.00

Vfixed, kN=V*(L1-L2)/L1=
Mfixed, kNm=Vfixed*C1=

0.00
0.00

Longitudinal

Vfix&mob, kN=V/2=
Vax sliding, kN=V*C1/L1=

0.00
0.00

Vax fixed, kN= -V*C1/L1=

0.00

You might also like