Professional Documents
Culture Documents
Bs en 10224
Bs en 10224
10220:2002
BRITISH STANDARD
Incorporating
corrigendum no. 1
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
BS EN 10220:2002
National foreword
This British Standard is the official English language version of
EN 10220:2002. It supersedes BS 3600:1997 and DD ENV 10220:1994 which
are withdrawn.
The UK participation in its preparation was entrusted to Technical Committee
ISE/8, Steel pipes, which has the responsibility to:
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
Date
16892
Corrigendum No. 1
Comments
BSI 2007
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
EUROPEAN STANDARD
EN 10220
NORME EUROPENNE
EUROPISCHE NORM
December 2002
English version
2002 CEN
B-1050 Brussels
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EN 10220:2002 (E)
Contents
page
Foreword......................................................................................................................................................................3
1
Scope ..............................................................................................................................................................4
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
Bibliography ................................................................................................................................................................9
2
Copyright British Standards Institution
Provided by IHS under license with BSI - Uncontrolled Copy
No reproduction or networking permitted without license from IHS
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
EN 10220:2002 (E)
Foreword
This document (EN 10220:2002) has been prepared by Technical Committee ECISS/TC 29, "Steel tubes and
fittings for steel tubes", the Secretariat of which is held by UNI.
When transforming the European Prestandard ENV 10220 into this European Standard EN 10220, ECISS/TC 29
regarded it as necessary to avoid any conflict with and to deviate as little as possible from ISO 4200:1991 because
of the international trade in steel tubes and tubular products.
Table 1 of ENV 10220, which is identical with Table 2 of ISO 4200:1991, was therefore left unchanged for
EN 10220.
Table 2 of EN 10220 contains dimensions for heavy wall tubes, that are not covered by ISO 4200:1991.
All parts of the European Standard series EN 10305 on steel tubes for precision applications contain tables with
preferred dimensions, that are specific for the various parts of the standards series and the products and fields of
application specified therein. Therefore, Table 3 from ENV 10220 with preferred dimensions for steel tubes for
precision applications has become unnecessary, and has not been included in this standard.
This document supersedes ENV 10220:1993.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,
Sweden, Switzerland and the United Kingdom.
3
Copyright British Standards Institution
Provided by IHS under license with BSI - Uncontrolled Copy
No reproduction or networking permitted without license from IHS
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by June 2003, and conflicting national standards shall be withdrawn at the latest by
June 2003.
EN 10220:2002 (E)
Scope
This European Standard specifies, for seamless and welded circular steel tubes for general purposes (e. g.
mechanical, pressure and structural applications), the following:
preferred dimensions for outside diameter and wall thickness in millimetres and
masses per unit length in kilogrammes per metre of plain end tube.
Technical Committees of ECISS and CEN should select these preferred dimensions for their product or functional
standards, where appropriate.
The outside diameters are classified into three series reflecting the availability of accessories for piping systems
(see Clause 4). This classification of outside diameters into different series and of preferred wall thicknesses
indicates the range of steel tubes usually produced.
NOTE
Information on dimensions for steel tubes for special applications can be found in other European
Standards, e.g. prEN 10255, EN 10305 series, EN ISO 11960 and EN ISO 11961, information on dimensions for
stainless steel tubes in EN ISO 1127.
Normative references
This European Standard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and publications are listed hereafter. For dated
references, subsequent amendments to or revisions of any of these publications apply to this European Standard
only when incorporated in it by amendment or revision. For undated references the latest edition of the publication
referred to applies (including amendments).
prEN 10266, Steel tubes, fittings and structural hollow sections Symbols and definition of terms for use in product
standards.
For the purpose of this European Standard the terms and definitions in prEN 10266 apply.
The outside diameters given in Tables 1 and 2 are classified into three series which may be described in the
following way:
series 1: outside diameters for which all the accessories needed for the construction of piping systems are
standardized;
series 2: outside diameters for which not all accessories are standardized;
series 3: outside diameters for which very few standardized accessories exist.
NOTE 1 It is recommended to select, for tubes intended to be used as components of piping systems, outside diameters from
series 1 in Table 1. Tubes with outside diameters in accordance with series 2 and 3 may not, or not easily, be available.
NOTE 2 Accessories for heavy wall tubes with dimensions in accordance with Table 2 may not be available regardless of the
series in Table 1 to which the relevant outside diameter is allocated.
4
Copyright British Standards Institution
Provided by IHS under license with BSI - Uncontrolled Copy
No reproduction or networking permitted without license from IHS
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
EN 10220:2002 (E)
The masses per unit length given in Tables 1 and 2 have been calculated from outside diameter D and wall
thickness T to at least five significant figures, using the formula given below. They have been rounded to three
significant figures for values of less than 100 and to the nearest whole number for larger values.
M = (D - T) T x 0,02466151) kg/m
where
NOTE EN 10088-1 provides distinguished density values for various groups of stainless steel grades which may be used for
calculating purposes.
Table 1 gives dimensions consisting of outside diameters D, from 3 series as described in Clause 4, and related
wall thicknesses T 65 mm and the calculated masses per unit length of plain end tube.
Table 2 gives dimensions consisting of outside diameters D and related wall thicknesses T from 70 mm to 100 mm
and the calculated masses per unit length of plain end tube.
1)
2)
3)
5
Copyright British Standards Institution
Provided by IHS under license with BSI - Uncontrolled Copy
No reproduction or networking permitted without license from IHS
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
The calculated values may also be applied to tubes with different density values, but have then to be multiplied by
a factor of
EN 10220:2002 (E)
Table 1 Dimensions (wall thicknesses T 65 mm) and masses per unit length
Outside diameter
D
mm
series
1
2
3
10,2
12
12,7
13,5
14
16
17,2
18
19
20
21,3
22
25
25,4
26,9
30
31,8
32
33,7
35
38
40
42,4
44,5
Wall thickness T, mm
0,5
0,6
0,8
1,2
1,4
1,6
1,8
0,120
0,142
0,150
0,160
0,166
0,191
0,206
0,216
0,228
0,240
0,256
0,265
0,302
0,307
0,326
0,364
0,386
0,388
0,409
0,425
0,462
0,487
0,517
0,543
0,142
0,169
0,179
0,191
0,198
0,228
0,246
0,257
0,272
0,287
0,306
0,317
0,361
0,367
0,389
0,435
0,462
0,465
0,490
0,509
0,553
0,583
0,619
0,650
0,706
0,746
0,790
0,835
0,883
0,931
0,185
0,221
0,235
0,251
0,260
0,300
0,324
0,339
0,359
0,379
0,404
0,418
0,477
0,485
0,515
0,576
0,612
0,616
0,649
0,675
0,734
0,773
0,821
0,862
0,937
0,990
1,05
1,11
1,17
1,24
1,37
1,42
1,49
1,61
1,74
0,227
0,271
0,289
0,308
0,321
0,370
0,400
0,419
0,444
0,469
0,501
0,518
0,592
0,602
0,639
0,715
0,760
0,765
0,806
0,838
0,912
0,962
1,02
1,07
1,17
1,23
1,31
1,38
1,46
1,54
1,70
1,78
1,85
2,01
2,17
0,266
0,320
0,340
0,364
0,379
0,438
0,474
0,497
0,527
0,556
0,595
0,616
0,704
0,716
0,761
0,852
0,906
0,911
0,962
1,00
1,09
1,15
1,22
1,28
1,39
1,47
1,56
1,65
1,75
1,84
2,04
2,12
2,22
2,41
2,60
2,97
3,16
3,35
0,304
0,366
0,390
0,418
0,435
0,504
0,546
0,573
0,608
0,642
0,687
0,711
0,815
0,829
0,880
0,987
1,05
1,06
1,12
1,16
1,26
1,33
1,42
1,49
1,62
1,71
1,82
1,92
2,03
2,14
2,37
2,47
2,58
2,80
3,02
3,46
3,68
3,90
0,339
0,410
0,438
0,470
0,489
0,568
0,616
0,647
0,687
0,726
0,777
0,805
0,923
0,939
0,998
1,12
1,19
1,20
1,27
1,32
1,44
1,52
1,61
1,69
1,84
1,95
2,07
2,19
2,32
2,44
2,70
2,82
2,94
3,19
3,44
3,95
4,20
4,45
4,95
5,18
5,45
5,51
5,95
6,21
6,58
0,373
0,453
0,484
0,519
0,542
0,630
0,684
0,719
0,764
0,808
0,866
0,897
1,03
1,05
1,11
1,25
1,33
1,34
1,42
1,47
1,61
1,70
1,80
1,90
2,06
2,18
2,32
2,45
2,60
2,74
3,03
3,16
3,30
3,58
3,87
4,43
4,71
4,99
5,56
5,82
6,12
6,19
6,69
6,98
7,39
7,81
8,52
9,65
0,404
0,493
0,528
0,567
0,592
0,691
0,750
0,789
0,838
0,888
0,952
0,996
1,13
1,15
1,23
1,38
1,47
1,48
1,56
1,63
1,78
1,87
1,99
2,10
2,28
2,42
2,56
2,71
2,88
3,03
3,35
3,50
3,65
3,97
4,29
4,91
5,23
5,54
6,17
6,46
6,79
6,87
7,42
7,74
8,20
8,67
9,46
10,7
12,0
13,4
48,3
51
54
57
60,3
63,5
70
73
76,1
82,5
88,9
101,6
108
114,3
127
133
139,7
141,3
152,4
159
168,3
177,8
193,7
219,1
244,5
273
323,9
355,6
406,4
457
508
559
610
2,3
2,6
2,9
Mass per unit length, kg/m
0,448
0,550
0,590
0,636
0,664
0,777
0,845
0,891
0,947
1,00
1,08
1,12
1,29
1,31
1,40
1,57
1,67
1,68
1,78
1,85
2,02
2,14
2,27
2,39
2,61
2,76
2,93
3,10
3,29
3,47
3,84
4,01
4,19
4,55
4,91
5,63
6,00
6,35
7,07
7,41
7,79
7,88
8,51
8,89
9,42
9,95
10,9
12,3
13,7
15,4
0,487
0,603
0,648
0,699
0,731
0,859
0,936
0,987
1,05
1,12
1,20
1,24
1,44
1,46
1,56
1,76
1,87
1,89
1,99
2,08
2,27
2,40
2,55
2,69
2,93
3,10
3,30
3,49
3,70
3,90
4,32
4,51
4,71
5,12
5,53
6,35
6,76
7,16
7,98
8,36
8,79
8,89
9,61
10,0
10,6
11,2
12,3
13,9
15,5
17,3
20,6
22,6
25,9
0,651
0,701
0,758
0,794
0,937
1,02
1,08
1,15
1,22
1,32
1,37
1,58
1,61
1,72
1,94
2,07
2,08
2,20
2,30
2,51
2,65
2,82
2,98
3,25
3,44
3,65
3,87
4,11
4,33
4,80
5,01
5,24
5,69
6,15
7,06
7,52
7,97
8,88
9,30
9,78
9,90
10,7
11,2
11,8
12,5
13,6
15,5
17,3
19,3
23,0
25,2
28,9
3,2
3,6
0,694
0,750
0,813
0,852
1,01
1,10
1,17
1,25
1,33
1,43
1,48
1,72
1,75
1,87
2,11
2,26
2,27
2,41
2,51
2,75
2,90
3,09
3,26
3,56
3,77
4,01
4,25
4,51
4,76
5,27
5,51
5,75
6,26
6,76
7,77
8,27
8,77
9,77
10,2
10,8
10,9
11,8
12,3
13,0
13,8
15,0
17,0
19,0
21,3
25,3
27,8
31,8
35,8
39,8
43,9
47,9
0,879
0,923
1,10
1,21
1,28
1,37
1,46
1,57
1,63
1,90
1,94
2,07
2,34
2,50
2,52
2,67
2,79
3,05
3,23
3,44
3,63
3,97
4,21
4,47
4,74
5,03
5,32
5,90
6,16
6,44
7,00
7,57
8,70
9,27
9,83
11,0
11,5
12,1
12,2
13,2
13,8
14,6
15,5
16,9
19,1
21,4
23,9
28,4
31,3
35,8
40,3
44,8
49,3
53,8
660
711
762
813
864
914
1016
1067
1118
1168
1219
1321
1422
1524
1626
1727
1829
1930
2032
2134
2235
2337
2438
2540
6
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
4,5
1,18
1,3
1,38
1,48
1,58
1,71
1,78
2,07
2,11
2,26
2,56
2,74
2,76
2,93
3,06
3,35
3,55
3,79
4,00
4,37
4,64
4,93
5,23
5,55
5,87
6,51
6,81
7,11
7,74
8,38
9,63
10,3
10,9
12,1
12,7
13,4
13,5
14,6
15,3
16,2
17,1
18,7
21,2
23,7
26,5
31,6
34,7
39,7
44,7
49,7
54,7
59,8
64,7
69,7
74,8
79,8
84,8
89,8
99,8
1,41
1,50
1,61
1,72
1,86
1,94
2,28
2,32
2,49
2,83
3,03
3,05
3,24
3,38
3,72
3,94
4,21
4,44
4,86
5,16
5,49
5,83
6,19
6,55
7,27
7,60
7,95
8,66
9,37
10,8
11,5
12,2
13,6
14,3
15,0
15,2
16,4
17,1
18,2
19,2
21,0
23,8
26,6
29,8
35,4
39,0
44,6
50,2
55,9
61,5
67,2
72,7
78,4
84,1
89,7
95,4
101
112
5,4
1,73
1,85
2,01
2,10
2,47
2,52
2,70
3,08
3,30
3,33
3,54
3,70
4,07
4,32
4,61
4,87
5,34
5,67
6,04
6,41
6,82
7,21
8,01
8,38
8,77
9,56
10,3
11,9
12,7
13,5
15,0
15,8
16,6
16,8
18,2
19,0
20,1
21,3
23,3
26,4
29,5
33,0
39,3
43,2
49,5
56,7
62,0
68,3
74,6
80,8
87,1
93,3
99,6
106
112
125
131
137
143
150
2,12
2,21
2,61
2,66
2,86
3,28
3,52
3,54
3,77
3,94
4,34
4,61
4,93
5,21
5,71
6,07
5,47
6,87
7,31
7,74
8,60
9,00
9,42
10,3
11,1
12,8
13,7
14,5
16,2
17,0
17,9
18,1
19,6
20,5
21,7
23,0
25,1
28,5
31,8
35,6
42,4
46,6
53,4
60,1
66,9
73,7
80,5
87,2
94,0
101
108
114
121
135
141
148
155
162
5,6
6,3
2,68
2,73
2,94
3,27
3,62
3,65
3,88
4,06
4,47
4,75
5,08
5,37
5,90
6,27
6,68
7,10
7,55
8,00
8,89
9,31
9,74
10,6
11,5
13,3
14,1
15,0
16,8
17,6
18,5
18,7
20,3
21,2
22,5
23,8
26,0
29,5
33,0
36,9
44,0
48,3
55,4
62,3
69,4
76,4
83,5
90,4
97,4
104
112
119
125
140
147
154
161
168
182
196
2,91
2,97
3,20
3,68
3,96
3,99
4,26
4,46
4,93
5,24
5,61
5,94
6,53
6,94
7,41
7,88
8,39
8,89
9,90
10,4
10,8
11,8
12,8
14,8
15,8
16,8
18,8
19,7
20,7
21,0
22,7
23,7
25,2
26,6
29,1
33,1
37,0
41,4
49,3
54,3
62,2
70,0
77,9
85,9
93,8
102
109
117
125
133
141
157
165
173
180
188
204
220
236
252
EN 10220:2002 (E)
Table 1 (continued)
Outside diameter
D
mm
series
1
2
3
Wall thickness T, mm
7,1
8,8
10
11
12,5
14,2
16
17,5
20
22,2
25
28
30
32
36
40
45
50
55
60
65
57,7
62,4
71,8
76,2
81,2
82,3
90,6
95,4
102
109
121
140
159
180
217
241
278
316
354
391
429
466
504
542
579
617
654
729
767
805
842
880
955
1030
1105
1181
1256
1331
1406
1481
1557
1631
1707
1782
1857
64,9
75,0
79,7
85,0
86,3
95,0
100
108
115
128
148
168
190
230
255
295
335
376
416
456
496
536
576
616
657
696
777
817
857
896
937
1017
1097
1177
1258
1338
1418
1498
1578
1659
1739
1819
1899
1979
80,8
86,1
92,1
93,5
103
109
117
126
140
163
185
210
256
284
329
374
419
464
510
554
599
645
690
735
780
870
915
961
1005
1050
1141
1231
1321
1412
1501
1592
1682
1772
1863
1952
2043
2133
2223
91,7
98,4
99,9
111
117
127
136
152
177
202
230
280
311
361
411
462
512
562
612
662
712
763
813
862
963
1013
1063
1113
1163
1264
1363
1464
1565
1664
1765
1864
1965
2066
2165
2266
2366
2466
119
127
137
147
165
193
221
253
310
345
401
457
514
570
627
683
739
796
852
909
964
1078
1134
1191
1246
1303
1416
1528
1641
1755
1867
1980
2092
2205
2318
2430
2544
2656
2769
146
158
177
209
240
275
338
377
439
502
565
628
691
752
815
878
941
1004
1065
1191
1254
1317
1379
1441
1567
1692
1818
1943
2068
2194
2318
2444
2570
2694
2820
2945
3070
167
188
223
257
296
365
408
477
545
614
684
753
821
890
959
1028
1097
1165
1303
1373
1442
1510
1579
1717
1854
1993
2131
2268
2406
2543
2682
2820
2957
3095
3232
3371
198
235
273
315
390
437
513
587
663
738
814
888
963
1039
1114
1190
1264
1415
1490
1556
1639
1715
1866
2015
2166
2317
2467
2618
2767
2918
3069
3218
3369
3519
3670
247
288
333
415
466
547
628
710
792
874
954
1036
1117
1199
1281
1361
1524
1606
1688
1768
1850
2013
2175
2339
2502
2664
2828
2990
3153
3317
3479
3642
3804
3967
10,2
12
12,7
13,5
14
16
17,2
18
19
20
21,3
22
25
30
31,8
32
33,7
35
38
40
42,4
44,5
48,3
51
54
57
60,3
63,5
70
73
76,1
82,5
88,9
101,6
108
114,3
127
133
139,7
141,3
152,4
159
168,3
177,8
193,7
219,1
244,5
273
323,9
355,6
406,4
457
508
559
610
660
711
762
813
864
914
1016
1067
1118
1168
1219
1321
1422
1524
1626
1727
1829
1930
2032
2134
2235
3,47
4,01
4,32
4,36
4,66
4,89
5,41
5,76
6,18
6,55
7,21
7,69
8,21
8,74
9,32
9,88
11,0
11,5
12,1
13,2
14,3
16,5
17,7
18,8
21,0
22,0
23,2
23,5
25,4
26,6
28,2
29,9
32,7
37,1
41,6
46,6
55,5
61,0
69,9
78,8
87,7
96,6
106
114
123
132
141
150
159
177
186
195
203
212
230
248
266
283
301
319
3,73
4,34
4,70
4,74
5,07
5,33
5,92
6,31
6,79
7,20
7,95
8,48
9,08
9,67
10,3
10,9
12,2
12,8
13,4
14,7
16,0
18,5
19,7
21,0
23,5
24,7
26,0
26,3
28,5
29,8
31,6
33,5
36,6
41,6
46,7
52,3
62,3
68,6
78,6
88,6
98,6
109
119
129
139
149
159
169
179
199
209
219
229
239
259
279
299
319
339
359
379
399
5,40
5,69
6,34
6,77
7,29
7,75
8,57
9,16
9,81
10,5
11,2
11,9
13,3
13,9
14,6
16,0
17,4
20,1
21,5
22,9
25,7
27,0
28,4
28,8
31,2
32,6
34,6
36,7
40,1
45,6
51,2
57,3
68,4
75,3
86,3
97,3
108
119
130
141
152
163
175
186
196
219
230
241
252
263
285
307
329
351
373
395
417
439
461
483
2337
2438
2540
6,91
7,40
7,99
8,51
9,45
10,1
10,9
11,6
12,4
13,2
14,8
15,5
16,3
17,9
19,5
22,6
24,2
25,7
28,9
30,3
32,0
32,4
35,1
36,7
39,0
41,4
45,3
51,6
57,8
64,9
77,4
85,2
97,8
110
123
135
148
160
173
185
198
211
223
248
261
273
286
298
323
348
373
399
423
449
4 74
499
524
549
574
599
624
9,09
10,1
10,9
11,7
12,5
13,4
14,2
16,0
16,8
17,7
19,4
21,1
24,6
26,3
28,0
31,5
33,1
34,9
35,3
38,4
40,1
42,7
45,2
49,6
56,5
63,3
71,1
84,9
93,5
107
121
135
149
162
176
190
204
218
231
245
273
286
300
314
328
355
383
410
438
466
493
521
548
576
604
631
658
686
9,86
11,0
11,9
12,8
13,7
14,7
15,7
17,7
18,7
19,6
21,6
23,6
27,5
29,4
31,4
35,3
37,1
39,2
39,7
43,1
45,2
48,0
51,0
55,9
63,7
71,5
80,3
96,0
106
121
137
153
168
184
200
215
231
247
262
278
309
325
341
356
372
403
435
466
497
529
560
591
623
654
685
717
748
779
13,9
15,0
16,1
17,3
19,5
20,6
21,7
23,9
26,2
30,6
32,8
35,1
39,5
41,6
43,9
44,5
48,4
50,7
54,0
57,3
62,9
71,8
80,6
90,6
108
120
137
155
173
191
209
226
244
262
280
298
315
351
369
387
404
422
458
493
529
564
600
636
671
707
742
778
813
849
885
17,5
18,7
21,3
22,5
23,7
26,2
28,8
33,8
36,3
38,8
43,8
46,2
48,8
49,4
53,8
56,4
60,1
63,8
70,1
80,1
90,2
101
121
134
154
174
194
214
234
254
274
294
314
335
354
395
415
435
455
475
515
555
595
635
675
715
755
795
836
876
916
956
996
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
25,4
26,9
22,7
24,0
25,3
28,1
30,8
36,3
39,1
41,8
47,3
49,8
52,7
53,4
58,2
61,1
65,1
69,2
76,0
87,0
98,0
110
132
146
168
190
212
234
256
277
299
321
343
365
387
431
453
475
497
519
563
606
650
694
738
782
825
869
913
957
1001
1045
1089
27,7
30,8
34,0
40,2
43,4
46,5
52,8
55,7
59,0
59,8
65,3
68,6
73,1
77,8
85,7
98,2
111
125
150
166
191
216
241
266
291
316
341
366
391
416
441
491
516
542
566
591
642
692
742
792
842
892
942
992
1043
1093
1143
1193
1243
33,0
36,5
43,5
47,0
50,4
57,4
60,7
64,3
65,2
71,3
74,9
80,0
85,2
93,9
108
122
137
165
183
210
238
266
294
322
349
377
405
433
461
488
544
572
600
627
655
711
766
822
878
933
989
1044
1100
1156
1211
1267
1323
1378
39,4
47,2
51,2
55,1
62,9
66,6
70,7
71,7
78,5
82,6
88,3
94,2
104
120
135
153
184
204
235
266
298
329
361
392
423
454
486
517
548
611
642
674
705
736
799
861
924
987
1049
1112
1175
1237
1300
1363
1425
1488
1551
50,8
55,2
59,6
68,4
72,5
77,1
78,2
85,9
90,5
96,9
103
114
132
149
169
204
226
261
296
331
367
402
436
472
507
542
577
612
682
717
753
787
822
893
963
1033
1103
1173
1244
1313
1384
1454
1524
1594
1664
1735
7
Copyright British Standards Institution
Provided by IHS under license with BSI - Uncontrolled Copy
No reproduction or networking permitted without license from IHS
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
EN 10220:2002 (E)
Table 2 Dimensions (wall thicknesses 70 mm T 100 mm) and masses per unit length
Outside Diameter
70
D
mm
219,1
244,5
273
323,9
355,6
406,4
457
508
559
610
660
711
257
301
350
438
493
581
668
756
844
932
1019
1107
Wall thickness T, mm
80
90
Mass per unit length
kg/m
325
381
481
544
644
744
844
945
1046
1144
1245
519
590
702
815
928
1041
1154
1265
1378
8
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
100
552
630
765
880
1006
1132
1258
1381
1507
EN 10220:2002 (E)
Bibliography
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT
BS EN
10220:2002
--`,``,,,`,`,`````,```,,,`,,,-`-`,,`,,`,`,,`---
BSI
389 Chiswick High Road
London
W4 4AL
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email: copyright@bsi-global.com.
Licensee=BP International/5928366101
Not for Resale, 08/12/2009 10:36:25 MDT