Fanuc 18 Control
Cable
In MDI mode, press the OFFSET SETTING key until the Setting (Handy) screen is shown. Set the Parameter Write
value to ON:1. The machine will go into Alarm mode as you are setting the parameters. Press the OFFSET
SETTING key again and set the I/O Channel = 0 for RS-232. Press the SYSTEM key and Page down to Parameter
0100
Parameter 0100
ENS
IOP
ND3
NCR
0
CTV
0
Parameter 0101
NFD
0
ASI
0
http://wgmlti1/webhelp/html/fanuc_16_18_series_controls.html
SB2
0
30/08/2016
Pgina 2 de 2
Parameter 0102
DEVICE NUM. (CH 0) = 0
Parameter 0103
BAUDRATE (CH. 0) = 12 for 19,200 baud
1.
When finished setting the parameters set the Parameter Write value back to 0 and hit Reset. On the Setting page,
TV Check is 0 (Off), Punch Code is 1 (ISO), and I/O Channel is either 0 or 1.
2.
On 16-18 Series Controls using ISO format, only Baud rate and # of stop bits can be set. Always use Even parity,
Word length 7, and 2 Stop bits.
4.
To do Direct (Drip Feed) DNC, first change to tape mode on the CNC Contro. Pick your file to send at Multi-DNC to
Send and Wait for XON, hit Cycle Start at the CNC. To pause Direct DNC turn Feedrate Override to 0%.
Control Parameters
#0020=0 (I/O = 0 or =1)
Multi-DNC Setup
http://wgmlti1/webhelp/html/fanuc_16_18_series_controls.html