Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

Pile Cap of Footing F1:

fc'(N/mm2) = 21
fy(N/mm2) = 275
Total SL on Column(kN) =
Column dia(mm) =
Total number of pile =
Dia of pile(mm) =
Pile c/c Spacing(times dia) =
Edge offset of Cap(mm) =
Short dimension of cap(mm) =
Long dimension of cap(mm) =
Av. Load factor =
Total FL on Column(kN) =
FL on Each Pile(kN) =

805
625
2
450
3
150
925
2100
1.45
1167
584

Depth of Cap(mm) = 1000

Column Punching:
Effective Depth of Cap(mm) =
Design Shear Strength(N/mm2) =
Punching area(mm2) =
Concrete Punching Shear(kN) =

820
1.29
1517000
1963
OK

Pile Punching:
Effective Depth of Cap(mm) =
Design Shear Strength(N/mm2) =
Punching area(mm2) =
Concrete Punching Shear(kN) =

820
1.29
758500
981
OK

Flexaral Shear:
Dist. Of CS from CC(mm) =
Dist. Of PC from CC(mm) =
Applied Shear(kN) =
Design Shear Strength(Nmm2) =
Design Shear(kN) =

1097
675
0
0.65
491
OK

Moment:
Moment(kN-m) = 232
Mu(kN-m) Mu(kN-m)
(ABS)
232.28
232.28

E. depth
(mm)
820

Width
(mm)
925

Mu1
(kN-m)
3413.21

Mu2
(kN-m)
0.00

As(mm2)

As'(mm2)

1158

Temperature reinf.(mm2)= 578

Minimum reinf.(mm2)= 3861


1.33 TimesMinimum reinf.(mm2)= 1540