Download as pdf or txt
Download as pdf or txt
You are on page 1of 200

energy for a better world

PRODUCT CATALOGUE 2014

Foreword
TRITEC means clean energy. The cleanest energy comes
from the sun: today and in the future. Energy for a better
world is our motto. This guiding theme includes not only
the environmental aspect, but it also and simultaneously
places an important social demand on the global energy
supply.
For more than 27 years, TRITEC has been an international
photovoltaic system supplier and centre of competence in
the area of renewable energies. All components of a photovoltaic system must be perfectly coordinated, in order
to achieve optimal efficiency. As your solar specialist and
partner, we will advise and support you in planning your
solar systems. You will find everything regarding technical
advice, product software, documentation and training in
the chapter Customer Support and Services.
In addition to the perfect coordination of the individual
PV components, the quality of each individual product is
essential. After all, systems generating solar energy are exposed to the hardest weather conditions for many years.
For this reason we only use A-brands as we only work with
manufacturers guaranteeing the highest quality. You can
find our products and photovoltaic system components on
page 10 et seqq.
TRITEC is also a system integrator and manufacturer of
own brand products. During the planning and installation
of small and medium-sized photovoltaic systems we work
with qualified partner companies. As international system
integrator we implement large photovoltaic systems and
test state-of-the-art installation technologies, which will
then be established in practical use. To see examples of
our range of applications, please visit www.tritec-energy.
com/reference-cases.

Solar Power Plant 11.6 kWp, Jungfraujoch (Switzerland)


In co-operation with TRITEC

As a manufacturer of our own products, we are focused


on PV mounting systems and PV measuring technology.
Our own mounting systems include our TRI-STAND and
TRI-FLAT variants, as well as TRI-VENT and TRI-ROOF (see
chapter Mounting Systems). The dimensioning software
TRI-DESIGN is used for the optimum dimensioning of PV
systems for any type of roof. TRI-KA, the handy characteristics analyser, is the ideal device for the performance
check of PV systems.
Do you want to know more about our products?
Get advice or visit a product training course in your area.
Our catalogue is continuously updated; find more information at: www.tritec-energy.com/products

Contents
PHOTOVOLTAICS
Introduction

Grid-connected Systems

PRODUCTS
Solar Modules

11-29

Grid-connected Inverters

31-67

Control and Measuring Instruments

69-87

Mounting Systems Components

89-121

Mounting Systems Applications

123-147

Accessories

149-175

Storage Systems

177-189

CUSTOMER SUPPORT AND SERVICES


Product Software

193

Training Courses / Product Documentations

195

COMPANY
General Terms and Conditions

196

TRITEC Contacts

198

Imprint

199

Introduction to Photovoltaics
History of Photovoltaics

Potential of Photovoltaics

Photovoltaics are an essential part of the portfolio of renewable energies. At the EU level, the passing of the
Directive for Renewable Energies set a mandatory target:
By 2020, 20 per cent of the energy demand must be supplied by renewable energies. Feed-in tariffs and subsidies
have resulted in a boom in the construction of photovoltaic
installations worldwide. Currently, the 30 GW mark in solar power output has been exceeded worldwide. That output can provide 10 million households with clean energy.
And the newly installed photovoltaic output continues to
grow every year. Until 2015, average global growth of
33% per year can be expected.

The amount of sun energy impacting the earth as light and


warmth is 1.5 1018 kWh per annum; this corresponds approximately to the 15000-fold of the entire primary energy
consumption of humanity in 2006 (1.0 1014 kWh/year). This
irradiation energy can be captured by the photovoltaic
effect and partially converted to electricity, without the
generation of undesirable by-products such as emissions
(e.g. CO2) or nuclear waste.

Already in 1839, the French physicist Alexandre Edmond


Becquerel had discovered the photoelectric effect. But it
took more than 100 years, until the first technical application in satellite technology could be realised at the end of
the 50s. Driven by the energy crises of the 70s and supported by an increased environmental awareness, photovoltaics began to move towards economic efficiency 20
years later.

Central Europe on average can assume an annually irradiated output of 1000 kWh/m2, Southern Europe achieves
values of 1700 kWh/m2, some desert regions even more than
2300 kWh/m2. If Central Europe wanted to cover the worlds
power needs with the irradiated solar energy, an area of
400 by 400 kilometres would be required.

In a few years, these efforts will result in the so-called grid


parity the point when power generation using photovoltaics will be equal in costs to conventional power.

16,50

17
16
15
14
13
12

GWp/a

11
10
9
8
7,20

7
5,75

6
5
4

1,42

1,60

2,59

1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010

Year

Global market volume for photovoltaics systems

Global annual solar irradiation in kWh/m

Solarpraxis

meteonorm

Stade de Suisse 1.35 MWp, Bern (Switzerland)


Designed and installed by TRITEC

The Functional Principle of the Solar Cell

Todays solar cells mostly consist of the base material silicon,


that is divided into two layers (p and n layer) with different
electric properties by doping with boron or phosphorus
and thus becomes a diode. In contrast to the conventional
semiconductor diode found in electronic circuits and rectifiers, the solar cell is optimised to exploit incident sun light.
For this purpose solar cells are manufactured with as large
a surface as possible. The so-called p-n junction here is only
just below the surface exposed to the solar irradiation.
At the p-n junction an electric field is building that has a
pull effect on free (mobile in the material) charge carriers.
The photons (light energy packages) of the incident sun
light penetrate the cell material and now produce free
charge carriers (electrons and holes) in proximity to the p-n
junction. These are separated from the inner field and
swept to the electric connecting contacts on the top and
bottom side of the cell. There they are available for use in
an external circuit. Each cell has a usable voltage of 0.5 to
0.6 Volt, which can be increased to any value by connecting
several cells in series. In solar modules the cells are partially
connected in series and parallel, in order to achieve the optimum usable operating voltages.
The production rate of the free charge carriers increases in
proportion to the intensity of the solar irradiation. The
photons energy is converted to electric power to the
amount of approx. 15 % corresponding to the cells efficiency. The rest heats the solar cell and is discharged to the environment by means of heat transport processes. At standard test conditions (STC: 1000 W/m2, temperature 25 C,
AirMass 1.5) up to 2.5 Ampere solar power and therefore
approx. 1.5 W electric peak capacity can be expected per
dm2 of cell surface.
Due to their energy and material efficiency and therefore
due to their lower costs, thin-film technologies show the
greatest potential in the long term. Currently three different technologies are on the market: the amorphous/microcrystalline silicon technology, the CdTe based technology
and the copper indium selenide (CIS) technology. Though
these technologies are still in their infancy, manufacturers
are working flat out on their development.

Yield of a Photovoltaic Installation


The yield generated by a photovoltaic installation during a
year is also called solar yield. A significant factor for the
yield assessment of photovoltaic installations is the performance ratio. For this the yield of the photovoltaic installation is divided by the installed photovoltaic output and
the annual irradiation. A performance ratio of more than
80 % indicates a good ratio of yield and irradiated solar output. Among the factors affecting the yield are the location
of the photovoltaic installation, the orientation and the
climate or the intensity and length of the solar irradiation.

By means of special diagrams, the solar irradiation can be


calculated depending on the mounting angle and the orientation. In Central Europe the solar irradiation is greatest
at an orientation to the South and an angle of 30. A system with orientation to the South-West and a mounting
angle of 30 for example, would achieve an annual solar
irradiation of approx. 95 % of the maximum.
In order to enable photovoltaic installations to achieve
high yields, detailed planning is necessary. On the one
hand the used components must be adapted perfectly to
the individual requirements, and on the other attention
must be given to correct dimensioning and placement with
the least possible clouding. In addition, solar modules are
daily exposed to wind and weather and must work faultlessly in spite of all adversities. Therefore, high-quality and
durable products are another important prerequisite for
good yields of photovoltaic systems.

Grid-connected
Photovoltaic Systems
Design of Grid-connected Photovoltaic
Installations
Grid-connected systems are photovoltaic installations that
are connected to the public grid and feed the entire electric
power generated by the solar energy to the grid. The size
of a grid-connected system depends on different factors:
roof/facade surface, financial resources and statutory provisions. Most European private grid-connected systems have
an output of two to ten kilowatt. If an installation on a
pitched roof is supposed to achieve such a yield, the required roof surface for two kilowatt (PV) is approximately
18 m2 and approximately 90 m2 for ten kilowatt.
The essential components of grid-connected PV installation
are photovoltaic modules, inverters, a mounting system, a
protective device to automatically switch off in case of
mains malfunctions and a meter to record the amount of
power supplied. Two factors are essential for a high-yield
system: 1. The quality of the installed products, incl. accessories (e.g. wiring); 2. The different components must be
optimally coordinated.
For 27 years now, TRITEC has been a photovoltaic system
provider with a wide and premium range of quality products. We are happy to support you in the planning as well
as in case of queries regarding the approval and financing
of photovoltaic installations.

Functional principle of a crystalline solar cell

Solarpraxis

Annual irradiation (%)

DGS / Solarpraxis

1
2
8

1. PV array
2. Mounting system
3. Wiring
4. PV array combiner/junction box
5. Grid-connected inverter
6. Import/export meter
7. Connection to grid
8. Consumer loads

7
6

Principle of a grid-connected photovoltaic system

Solarpraxis

Solar Modules
To be able to guarantee top quality and long-term
investment returns despite harshest weather conditions,
we offer exclusively rst-class brand name products of
leading manufacturers. These are solar modules of the
latest generation suitable for photovoltaic systems of
any size.
11

HAREON SOLAR
JA SOLAR
KYOCERA
LG
PANASONIC
Q.CELLS
REC

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

Hareon Solar HR-Mono Modules with


monocrystalline cells
Hareon Solar
12

Hareon Solar Technology Co., Ltd. was founded in 2004


and, today, it is one of the largest silicon-wafer producers in China. With its completion of the rst module
production lines, Hareon Solar has at its disposal, since
2008, a fully-integrated production of PV components
from ingots to modules.

Reliable modules

With an outstanding module and cell efciency, the


modules of the HR-Mono series achieve very high efciencies. Even with a reduced incidence of light, the
modules realize a good performance yield thanks to
their excellent low-light behaviour. Before and after
lamination, every module is subjected to an electroluminescence test.

The solar modules manufactured by Hareon Solar have been


tested and certied by all recognised test institutes worldwide.

TRITEC quality controls


n

Regular quality controls in cooperation with the


Fraunhofer Institute in Freiburg
External quality controls of production on location
on behalf of TRITEC
Mechanical TV load test with the TRITEC mounting
system TRISTAND

Certicates and warranties


n

n
n
n

IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE, UL


Listed, CEC, VDE, RoHS, TV, PV CYCLE
25-year linear performance warranty
10-year product warranty
European warranty processing

The Ningbo plugs allow easy wiring of the modules, while


the specically developed module frames withstand loads
of up to 5400 N/m.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101538

0101355

0101554

0101528

0101550

0101527

Model

Hareon HR-200W24/Aab Mono


200 W +5 W, -0 W
1000 V
37.93 V
5.27 A
45.68 V
5.69 A
-0.310 %/C

Hareon HR-205W24/Aa Mono


205 W +5 W, -0 W
1000 V
37.83 V
5.42 A
45.68 V
5.90 A
-0.310 %/C

Hareon HR-250W18/Cbb Mono EU


250 W +5 W, -0 W
1000 V
30.59 V
8.17 A
37.59 V
8.79 A
-0.322 %/C

Hareon HR-255W18/Cbb Mono EU


255 W +5 W, -0 W
1000 V
30.69 V
8.31 A
37.73 V
8.93 A
-0.322 %/C

Hareon HR-265W18/Cb Mono EU


265 W +5 W, -0 W
1000 V
30.70 V
8.63 A
37.91 V
9.31 A
-0.322 %/C

Hareon HR-270W18/Cb Mono


270 W +5 W, -0 W
1000 V
30.80 V
8.77 A
38.10 V
9.45 A
-0.322 %/C

Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient open circuit
voltage
Temp. coefcient short circuit
current
Temp. coefcient nominal
power
Reverse current load
Max. string protection
Number of bypass diodes
Cells per module
Cell dimensions (L / W)
Cell connection
Cell technology
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per container
Max. load
Performance warranty *
Product warranty
Norms

0.047 %/C

0.047 %/C

0.055 %/C

0.055 %/C

0.055 %/C

0.055 %/C

-0.410 %/C

-0.410 %/C

-0.428 %/C

-0.428 %/C

-0.428 %/C

-0.428 %/C

15 A
15 A
3 pc.
72 pc.
125 mm / 125 mm
2 bus bar
Monocrystalline silicon
Ningbo, cable
900 mm each (+ / )
Black anodized
aluminium
Black
1580 mm / 808 mm /
40 mm
15.8 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

15 A
15 A
3 pc.
72 pc.
125 mm / 125 mm
2 bus bar
Monocrystalline silicon
Ningbo, cable
900 mm each (+ / )
Anodized aluminium
White
1580 mm / 808 mm /
40 mm
15.8 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Monocrystalline silicon
Ningbo, cable
900 mm each (+ / )
Black anodized
aluminium
Black
1636 mm / 992 mm /
40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Monocrystalline silicon
Ningbo, cable
900 mm each (+ / )
Black anodized
aluminium
Black
1636 mm / 992 mm /
40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Monocrystalline silicon
GZX, cable 900 mm
each (+ / )
Anodized aluminium
White
1636 mm / 992 mm /
40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Monocrystalline silicon
Ningbo, cable
900 mm each (+ / )
Anodized aluminium
White
1636 mm / 992 mm /
40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC
61730, CE, UL
Listed, CEC, RoHS,
ISO 9001, ISO
14001, TVdotCOM-ID:
0000026038, MCS,
PV CYCLE

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and
then a maximum output reduction of 0.7 % per year
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.
For Switzerland:
Art. No. 0101549 instead of 0101550
Art. No. 0101526 instead of 0101528

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

13

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

Hareon Solar HR-Poly Modules with polycrystalline cells


Hareon Solar
14

Hareon Solar Technology Co., Ltd. was founded in 2004


and today, it is one of the largest silicon-wafer producers in China. With its completion of the rst module
production lines, Hareon Solar has at its disposal, since
2008, a fully-integrated production of PV components
from ingots to modules.

Reliable modules

With an outstanding module and cell efciency, the


modules of the HR-Poly series achieve very high efciencies. Even with a reduced incidence of light, the
modules realize a good performance yield thanks to
their excellent low-light behaviour. Before and after
lamination, every module is subjected to an electroluminescence test.

The HR-Poly of Hareon Solar have been tested and certied


by all recognised test institutes worldwide.

TRITEC quality controls


n

Regular quality controls in cooperation with the


Fraunhofer Institute in Freiburg
External quality controls of production on location
on behalf of TRITEC
Mechanical TV load test with the TRITEC mounting
system TRISTAND

Certicates and warranties


n

n
n
n

IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE, UL


Listed, CEC, VDE, RoHS, TV, PV CYCLE
25-year linear performance warranty
10-year product warranty
European warranty processing

With their Ningbo connectors and the specically developed


40 mm frame (loads up to 5400 N/m), the Hareon solar
modules are suitable for universal applications.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101519

0101525

0101532

0101553

Model

Hareon HR-250P-18/Bb Poly


3BB EU
250 W +5 W, -0 W
1000 V
29.98 V
8.34 A
37.41 V
8.79 A
-0.32 %/C

Hareon HR-260P-18/Bb Poly


3BB
260 W +5 W, -0 W
1000 V
30.51 V
8.52 A
37.65 V
9.09 A
-0.32 %/C

Hareon HR-260P-18/Bb Poly


4BB
260 W +5 W, -0 W
1000 V
30.51 V
8.52 A
37.65 V
9.09 A
-0.32 %/C

Hareon HR-265P-18/Bb Poly


4BB EU
265 W +5 W, -0 W
1000 V
30.71 V
8.63 A
37.81 V
9.24 A
-0.32 %/C

Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient open circuit
voltage
Temp. coefcient short circuit
current
Temp. coefcient nominal
power
Reverse current load
Max. string protection
Number of bypass diodes
Cells per module
Cell dimensions (L / W)
Cell connection
Cell technology
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per container
Max. load
Performance warranty *
Product warranty
Norms

0.055 %/C

0.055 %/C

0.055 %/C

0.055 %/C

-0.44 %/C

-0.44 %/C

-0.44 %/C

-0.44 %/C

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
Ningbo, cable 900 mm each
(+ / )
Anodized aluminium
White
1636 mm / 992 mm / 40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, CE, UL
Listed, CEC, RoHS, ISO 9001,
ISO 14001, TVdotCOM-ID:
0000026038, MCS, PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
Ningbo, cable 900 mm each
(+ / )
Anodized aluminium
White
1636 mm / 992 mm / 40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, CE, UL
Listed, CEC, RoHS, ISO 9001,
ISO 14001, TVdotCOM-ID:
0000026038, MCS, PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
4 bus bar
Polycrystalline silicon
Ningbo, cable 900 mm each
(+ / )
Anodized aluminium
White
1636 mm / 992 mm / 40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, CE, UL
Listed, CEC, RoHS, ISO 9001,
ISO 14001, TVdotCOM-ID:
0000026038, MCS, PV CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
4 bus bar
Polycrystalline silicon
Ningbo, cable 900 mm each
(+ / )
Anodized aluminium
White
1636 mm / 992 mm / 40 mm
19.3 kg
700 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, CE, UL
Listed, CEC, RoHS, ISO 9001,
ISO 14001, TVdotCOM-ID:
0000026038, MCS, PV CYCLE

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and
then a maximum output reduction of 0.7 % per year
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

15

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

JA Solar Mono High reliability, top efciency


Convincing price/benet ratio
16

As one of the worldwide leading manufacturers of


high-powered photovoltaic products, JA Solar presents
high-quality modules with its JAM series. Due to their
outstanding efciencies, the modules realize an excellent price/benet ratio.

Solar modules for any application

Due to the optimized, highly-transparent, low-iron


tempered glass surfaces with very low reection values
and high-efciency silicon cells, JA modules provide
outstanding performance even in low light. Thanks
to their rugged construction, the modules withstand
even the most adverse weather conditions. A black
module variant is available for visually particularly
attractive PV systems.

A waterproof standard junction box with a bypass diode


and its rugged construction guarantee reliability for many
years.

Uncompromising quality
n

n
n
n

Tested resistance of the modules against ammonia


and salt mist
No PID effect
Dual electroluminescence test
State-of-the-art, automated production lines and
strict process controls
European test standards for module performance
controls

Certicates and warranties


n

n
n
n

IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE, UL


Listed, CEC, VDE, RoHS, TV, PV CYCLE
25-year linear performance warranty
10-year product warranty
European warranty processing

Thanks to highly efcient crystalline silicon cells, excellent


performance is ensured at low light conditions. Moreover,
the classication by current classes ensures optimum system
performance.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101488

0101542

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Operating module
temperature
Cells per module
Cell type
Cell dimensions (L / W)
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per container
Max. load
Performance warranty *
Product warranty
Norms

JA Solar JAM6(BK)-60-255/SI Mono


255 W +5 %, -0 %
1000 V
30.62 V
8.31 A
38.10 V
8.72 A
-0.430 %/C
-0.340 %/C
0.049 %/C
15 A
-40 to +85 C

JA Solar Percium JAM6-60-285-PR


285 W +5 %, -0 %
1000 V
32.26 V
8.83 A
39.43 V
9.38 A
-0.410 %/C
-0.340 %/C
0.049 %/C
15 A
-40 to +85 C

60 pc.
Monocrystalline silicon
156 mm / 156 mm
Cables 4 mm with TongLing connectors
Black anodized aluminium
Black
1650 mm / 991 mm / 40 mm
18.5 kg (approx.)
728 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, protection class II, CE mark, MCS, ISO
9001 (2008), ISO 14001 (2004), BS OHSAS 18001 (2007)

60 pc.
Monocrystalline silicon
156 mm / 156 mm
Cables 4 mm with TongLing connectors
Anodized aluminium
White
1650 mm / 991 mm / 40 mm
18.2 kg (approx.)
728 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, protection class II, CE mark, MCS, ISO
9001 (2008), ISO 14001 (2004), BS OHSAS 18001 (2007)

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and
then a maximum output reduction of 0.708 % per year
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

17

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

The KD series of Kyocera Large-format high


performance modules
Manufacturer with cutting-edge technology
18

Kyocera also decisively furthered the developments in


solar technology. Seven years after its foundation in
1975, the company had its rst series production of
polycrystalline silicon solar cells. In addition to its complete module production, Kyocera excels at its special
innovations in research and development. This regularly results in novel production methods and procedures and modules with record efciencies.

rugged aluminium frame withstands even high wind


and snow loads.

Highest quality demands


n

Long-lasting performance

The modules' outstanding efciency over a number of


years has been conrmed by several long-term tests
and by Stiftung Warentest (the leading German product testing and consumer advocacy organization). As a
protection against severest climate conditions, the cells
are embedded between a tempered glass cover and
EVA lm and sealed on the back with PET lm. The

Certicates and warranties


n

The junction box on the rear is provided with bypass diodes


which prevent the overheating risk of individual solar cells
(hot spot effect). Several series-connected PV modules may
be simply wired by pre-installed solar cables and plugs.

Low light reection of the modules due to the


"reactive ion etching" method (RIE) for higher efciency and optimum area utilization
Specied 5-step development process for every
module
Pairing: Sorting method ensures nominal performance of two paired modules
No PID effect

IEC 61215, IEC 61730, IEC 62716, IEC 61701, TV, CE,
MCS, PV CYCLE
Performance warranty: 10 years on 90 % and 25 years
on 80 % of the nominal power
10-year product warranty

Thanks to the textured silicon nitride, the 6" cell receives a


minor light reection and homogeneous coloration.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101544

0101431

0101545

0101434

0101547

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient open circuit
voltage
Temp. coefcient short circuit
current
Temp. coefcient nominal
power
Reverse current load
Max. string protection
Number of bypass diodes
Cells per module
Cell dimensions (L / W)
Cell connection
Cell technology
Connection

KD195GH-4FU
195 W 5 %
1000 V
23.60 V
8.27 A
29.50 V
9.05 A
-106.2 mV/K, 0.36 %/K

KD220GH-4YU
220 W +5 %, -3 %
1000 V
26.60 V
8.28 A
33.20 V
8.98 A
-119.52 mV/K, 0.36 %/K

KD220GH-4FU
220 W +5 %, -3 %
1000 V
26.60 V
8.28 A
33.20 V
8.98 A
-119.52 mV/K, 0.36 %/K

KD250GH-4YB2
250 W +5 %, -3 %
1000 V
29.80 V
8.39 A
36.90 V
9.09 A
-132.84 mV/K, 0.36 %/K

KD250GH-4FB2
250 W +5 %, -3 %
1000 V
29.80 V
8.39 A
36.90 V
9.09 A
-132.84 mV/K, 0.36 %/K

5.43 mA/K, 0.06 %/K

5.388 mA/K, 0.06 %/K

5.388 mA/K, 0.06 %/K

5.454 mA/K, 0.06 %/K

5.454 mA/K, 0.06 %/K

-897 mW/K, -0.46 %/K

-1012 mW/K, 0.46 %/K -1012 mW/K, 0.46 %/K -1150 mW/K, 0.46 %/K -1150 mW/K, 0.46 %/K

15 A
15 A
3 pc.
48 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
SMK PV-03, cables, 840
() / 1030 (+) mm
Black anodized
aluminium
White
1338 mm 2.5 mm /
990 mm 2.5 mm /
46 mm
16.0 kg
760 pc.
5400 N/m
10 / 25 years
10 years
IEC 61215 ed. 2, IEC
61730, protection class
II, TVdotCOM-ID:
0000023299, MCS, PV
CYCLE

15 A
15 A
3 pc.
54 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
SMK PV-03, cables, 900
() / 1100 (+) mm
Black anodized
aluminium
White
1500 mm 2.5 mm /
990 mm 2.5 mm /
46 mm
18.0 kg
680 pc.
5400 N/m
10 / 25 years
10 years
IEC 61215 ed. 2, IEC
61730, protection class
II, TVdotCOM-ID:
0000023299, MCS, PV
CYCLE

Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per truck
Max. load
Performance warranty *
Product warranty
Norms

15 A
15 A
3 pc.
54 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
SMK PV-03, cables, 900
() / 1100 (+) mm
Black anodized
aluminium
White
1500 mm 2.5 mm /
990 mm 2.5 mm /
46 mm
18.0 kg
680 pc.
5400 N/m
10 / 25 years
10 years
IEC 61215 ed. 2, IEC
61730, protection class
II, TVdotCOM-ID:
0000023299, MCS, PV
CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
SMK PV-03, cables, 960
() / 1190 (+) mm
Black anodized
aluminium
White
1662 mm 2.5 mm /
990 mm 2.5 mm /
46 mm
20.0 kg
640 pc.
5400 N/m
10 / 25 years
10 years
IEC 61215 ed. 2, IEC
61730, protection class
II, TVdotCOM-ID:
0000023299, MCS, PV
CYCLE

15 A
15 A
3 pc.
60 pc.
156 mm / 156 mm
3 bus bar
Polycrystalline silicon
SMK PV-03, cables, 960
() / 1190 (+) mm
Black anodized
aluminium
White
1662 mm 2.5 mm /
990 mm 2.5 mm /
46 mm
20.0 kg
640 pc.
5400 N/m
10 / 25 years
10 years
IEC 61215 ed. 2, IEC
61730, protection class
II, TVdotCOM-ID:
0000023299, MCS, PV
CYCLE

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC)
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

19

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

LG Solar MonoX Neon & Black High-quality


modules for any requirements
LG Electronics
20

LG Electronics, Inc. is among the worldwide leading


companies for electronic, information and communications products. Moreover, for 20 years LG has been
relying on the technology of renewable energies. The
company's offer comprises high-quality solar cells and
modules which are completely manufactured in Korea.

ance modules result in a higher output per area, lower


system costs and higher yields.

Premium quality "A" without any exception


n

Powerful technology

State-of-the-art manufacturing plants, certied test


laboratories and strict controls guarantee the high
quality of monocrystalline modules. Moreover, the
MonoX Black series combines top technical performance and a sophisticated design. The MonoX Neon
modules are based on N-type silicon. This results in a
higher efciency than with conventional P-type cells.
Thanks to the N-type technology, the high-perform-

LG solar modules have a high load capacity even in


extreme wind and weather conditions.

n
n

High quality standard exceeds statutory requirements


Comprehensive electroluminescence tests in different production stages
Tested resistance against ammonia and salt mist
Screwed frame for high stability

Certicates and warranties


n

n
n

IEC 61215, IEC 61730-1/-2, ISO 14001, ISO 9001,


OHSAS 18001, UL 1703
25-year linear performance warranty
10-year product warranty

MonoX Black modules combine technical progress and aesthetic appearance.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101502

0101555

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Operating module
temperature
Cells per module
Cell type
Cell dimensions (L / W)
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per truck
Max. load
Performance warranty *
Product warranty
Norms

LG 255 S1K-A3 MonoX Black


255 W +3 %, -0 %
1000 V
30.9 V
8.26 A
37.9 V
8.78 A
-0.44 %/C
-0.31 %/C
0.05 %/C
15 A
-40 to +90 C

LG 300 N1C-B3 MonoX Neon


300 W +3 %, -0 %
1000 V
32.0 V
9.40 A
39.8 V
9.98 A
-0.41 %/C
-0.29 %/C
0.04 %/C
20 A
-40 to +90 C

60 pc.
60 pc.
Monocrystalline silicon
Monocrystalline silicon
156 mm / 156 mm
156 mm / 156 mm
Cables 4 mm with MC4 connectors
Cables 4 mm with MC4 connectors
Black anodized aluminium
Black anodized aluminium
Black
White
1640 mm / 1000 mm / 35 mm
1640 mm / 1000 mm / 35 mm
16.8 kg 0.5 kg
16.8 kg 0.5 kg
756 pc.
756 pc.
5400 N/m
5400 N/m
25 years
25 years
10 years
10 years
IEC 61215, IEC 61730-1/-2, ISO 14001, ISO 9001, OHSAS 18001, IEC 61215, IEC 61730-1/-2, ISO 14001, ISO 9001, OHSAS 18001,
UL 1703
UL 1703

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % (MonoX Neon: 98 %) of the nominal power
for the 1st year and then a maximum output reduction of 0.7 % per year
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

21

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

Panasonic Modules with powerful HIT solar cells


HIT solar cell technology
22

All Panasonic modules are based on HIT solar cells


(Heterojunction with Intrinsic Thin layer). They consist
of monocrystalline hybrid wafers which are coated
with thin, amorphous silicon. Thanks to the state-ofthe-art manufacturing process, solar cells can be produced with very high efciencies and optimum energy
returns.

More performance per area

As compared to conventional solar cells of crystalline


silicon, HIT cells are convincing with their high energy
yield even at high temperatures. Even in bad light
conditions, excellent performance is achieved thanks
to the anti-reective glass.

Consistent quality testing


n

n
n
n

Certicates and warranties


n

The modules of the Panasonic HIT-N series are based on


hybrid HIT solar cells (amorphous and monocrystalline silicon) with the highest levels of efciency.

Minimal failure rate of below 0.01 % with over


3 million delivered modules in Europe
Guaranteed durability of the modules by long-term
TV test
Tested resistance against ammonia and salt mist
No PID effect
Uninterrupted traceability: all modules are measured and provided with an individual bar code

IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE, UL


Listed, CEC, VDE, RoHS, MCS, PV CYCLE
Performance warranty: 10 years on 90 % and 25 years
on 80 % of the nominal power
10-year product warranty

HIT cells generate solar electricity simultaneously on the


front and on the back side.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101530

0101531

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Cells per module
Cell type
Cell dimensions
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per truck
Max. load
Performance warranty *
Product warranty
Norms

Panasonic VBHN240SJ25
240 W +10 %, -5 %
1000 V
43.6 V
5.51 A
52.4 V
5.85 A
-0.29 %/C
-131 mV/C
1.76 mA/C
15 A
72 pc.
HIT solar cell, monocrystalline
125 / 125 mm
SMK connectors, cable 960 mm each (+ / )
Black anodized aluminium
White
1580 mm / 798 mm / 35 mm
15.0 kg
200 pc.
2400 N/m
10 / 25 years
10 years
IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOMID: 0000023431, MCS, PV CYCLE

Panasonic VBHN245SJ25
245 W +10 %, -5 %
1000 V
44.3 V
5.54 A
53.0 V
5.86 A
-0.29 %/C
-133 mV/C
1.76 mA/C
15 A
72 pc.
HIT solar cell, monocrystalline
125 / 125 mm
SMK connectors, cable 960 mm each (+ / )
Black anodized aluminium
White
1580 mm / 798 mm / 35 mm
15.0 kg
200 pc.
2400 N/m
10 / 25 years
10 years
IEC 61730, IEC 61215, CE mark, protection class II, TVdotCOMID: 0000023431, MCS, PV CYCLE

* - Manufacturer's performance warranty: 10 years on 90 % / 25 years on 80 % of the minimal nominal power under standard testing conditions (STC)
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

23

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

Hanwha Q.Cells High-quality monocrystalline


third generation modules
Leading in research and development

24

Within a few years, Hanwha Q.Cells has developed


from a solar cell manufacturer to a worldwide leading
photovoltaic systems enterprise. The quality modules
from German and Malaysian production are based on
the results of intensive research and development.
Since its foundation, Hanwha Q.Cells has developed
product standards which are valid until today for
example, the 6-inch solar cell or the full-square monocrystalline solar cell. The company has the largest technology centre of the solar industry which also comprises an accredited test laboratory and a module test
centre.

The third module generation yet higher


standards

In terms of performance, technology, design and tests,


maximum demands are made on the Q.Peak-G3 series.
In monocrystalline solar modules, the solar cell with its
full-square format and a new busbar layout provides
2 % more module power. Q.Peak BLK-G3 has a completely black design and thus also meets top aesthetic

High module efciency is guaranteed thanks to the fullsquare monocrystalline cell.

demands. Additionally, the slim module concept provides cost benets since 40 % more modules per container can be loaded.

Powerful and resilient


n

A 35 mm frame with aluminium alloy for low weight


and a high load capacity of up to 5400 Pa
Module glass with anti-reection technology
reduces undesirable reections by about 50 %
Salt water and ammonia resistant junction box and
plug connector with low contact resistance
Increased exibility thanks to an MC4-combinable
plug

Certicates and warranties


n

n
n
n
n

Since 2011, continuous and successful participation


in the VDE's Quality Tested Program
No PID effect
IEC 61215 (ed. 2), IEC 61730 (ed. 1), PV CYCLE, CE
Successful salt mist corrosion test
Product warranty for 12 years, and a 25-year linear
performance warranty

An open eld installation in Germany with Q.Peak modules.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101511

0101512

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Operating module
temperature
Cells per module
Cell type
Cell dimensions (L / W)
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per container
Max. load
Performance warranty *
Product warranty
Norms

Q.Peak-G3 270 Mono


270 W +5 W, -0 W
1000 V
31.16 V
8.74 A
38.67 V
9.28 A
-0.43 %/C
-0.33 %/C
0.04 %/C
20 A
-40 to +85 C

Q.Peak BLK-G3 265 Mono


265 W +5 W, -0 W
1000 V
31.32 V
8.54 A
38.52 V
8.98 A
-0.43 %/C
-0.33 %/C
0.04 %/C
20 A
-40 to +85 C

60 pc.
Monocrystalline silicon
156 mm / 156 mm
Cables 4 mm with Tyco PV4 connectors
Black anodized aluminium
White
1670 mm / 1000 mm / 35 mm
19 kg
754 pc.
5400 N/m
25 years
12 years
CE, VDE Quality Tested, IEC 61215 (ed. 2), IEC 61730 (ed. 1)

60 pc.
Monocrystalline silicon
156 mm / 156 mm
Cables 4 mm with Tyco PV4 connectors
Black anodized aluminium
Black
1670 mm / 1000 mm / 35 mm
19 kg
754 pc.
5400 N/m
25 years
12 years
CE, VDE Quality Tested, IEC 61215 (ed. 2), IEC 61730 (ed. 1)

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and
then a maximum output reduction of 0.6 % per year (25th year: 83 % of the nominal power)
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

25

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

Hanwha Q.Cells High-quality polycrystalline


third generation modules
Leading in research and development

26

Within a few years, Hanwha Q.Cells has developed


from a solar cell manufacturer to a worldwide leading
photovoltaic systems enterprise. The quality modules
from German and Malaysian production are based on
the results of intensive research and development.
Since its foundation, Hanwha Q.Cells has developed
product standards which are valid until today for
example, the 6-inch solar cell or the full-square monocrystalline solar cell. The company has the largest technology centre of the solar industry which also comprises an accredited test laboratory and a module test
centre.

The third module generation yet higher


standards

In terms of performance, technology, design and tests,


maximum demands are made on the Q.Pro-G3 series.
The polycrystalline solar modules are based on the
novel Q.Antum cell concept which guarantees high
performance classes. The electrical rear structure
reects light rays which passed unused through the
cell. Otherwise lost light energy can thus be converted

Use of the Q.Antum world record cell concept guarantees


high efciencies.

into current. Additionally, the slim module concept


provides cost benets since 40 % more modules per
container can be loaded.

Powerful and resilient


n

A 35 mm frame with aluminium alloy for low weight


and a high load capacity of up to 5400 Pa
Module glass with anti-reection technology
reduces undesirable reections by about 50 %
Salt water and ammonia resistant junction box and
plug connector with low contact resistance
Increased exibility thanks to an MC4-combinable
plug

Certicates and warranties


n

n
n
n
n

Since 2011, continuous and successful participation


in the VDE's Quality Tested Program
No PID effect
IEC 61215 (ed. 2), IEC 61730 (ed. 1), PV CYCLE, CE
Successful salt mist corrosion test
Product warranty for 12 years, and a 25-year linear
performance warranty

Q.Cells'modules meet maximum requirements in the


mechanical load test.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101508

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Operating module
temperature
Cells per module
Cell type
Cell dimensions (L / W)
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per container
Max. load
Performance warranty *
Product warranty
Norms

Q.Pro-G3 250 Poly


250 W +5 W, -0 W
1000 V
29.89 V
8.45 A
37.78 V
8.94 A
-0.43 %/C
-0.33 %/C
0.04 %/C
20 A
-40 to +85 C

27

60 pc.
Polycrystalline silicon
156 mm / 156 mm
Cables 4 mm with Tyco PV4 connectors
Anodized aluminium
White
1670 mm / 1000 mm / 35 mm
19 kg
754 pc.
5400 N/m
25 years
12 years
CE, VDE Quality Tested, IEC 61215 (ed. 2), IEC 61730 (ed. 1)

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the nominal power for the 1st year and
then a maximum output reduction of 0.6 % per year (25th year: 83 % of the nominal power)
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
SOLAR MODULES

Framed Modules

...................................................................................................................................................................

REC Peak Energy series Polycrystalline modules


with maximum power
Reliability and sustainability
28

The Norwegian REC Group with production facilities in


the U.S. and in Singapore is worldwide one of the
largest manufacturers of silicon materials, PV wafers,
solar cells and modules. The enterprise is also committed to sustainability in production where highest environmental standards apply. Thanks to new processes,
silicon production requires up to 90 % less energy than
conventional methods.

the glass increases energy generation even at low solar


irradiation.

Top quality
n

n
n

Outstanding stability and energy yield

The modules are easy to install and without earthing


wire. Despite their low weight, the modules have a
rugged and durable design which guarantees maximum durability for decades even under the most
adverse weather conditions. A special treatment of

Certicates and warranties


n

n
n

REC maximum performance modules combine sustainable


quality and reliable power output.

Cutting-edge production facilities with maximum


quality requirements
Completely vertical production chain from raw silicon all the way to the module
Outstanding low-light performance
Robust and sustainable product design
No PID effect

IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE, MCS,
PV CYCLE, BBA
25-year linear performance warranty
10-year product warranty

A fruit farm in Germany with a photovoltaics system from


REC.

...................................................................................................................................................................
Framed Modules

SOLAR MODULES

...................................................................................................................................................................

Art. No.

0101495

Model
Nominal power
Max. system voltage
Operating voltage
Operating current
Open circuit voltage
Short circuit current
Temp. coefcient power
Temp. coefcient voltage
Temp. coefcient current
Reverse current load
Operating module
temperature
Cells per module
Cell type
Cell dimensions (L / W)
Connection
Mounting frame
Back sheet
Dimensions (L / W / H)
Weight
Number per truck
Max. load
Performance warranty *
Product warranty
Norms

REC 260 PE Poly


260 W +5 W, -0 W
1000 V
30.7 V
8.50 A
37.8 V
9.01 A
-0.40 %/C
-0.27 %/C
0.024 %/C
25 A
-40 to +80 C

29

60 pc.
Polycrystalline silicon
156 mm / 156 mm
Cables 4 mm with MC4 connectors
Anodized aluminium
White
1665 mm 2.5 mm / 991 mm 2.5 mm / 38 mm 1 mm
18 kg
600 pc.
5400 N/m
25 years
10 years
IEC 61215, IEC 61730, IEC 62716, IEC 61701, CE mark, MCS, PV CYCLE, BBA

* - Manufacturer's performance warranty: 25 years linear performance warranty guarantees at least 97 % of the actual power output for the 1st year
and then a maximum output reduction of 0.7 % per year
The electrical specications are under standard test conditions (STC) of irradiance of 1000 W/m, spectrum of 1.5 air mass and cell temperature of 25C.
Photos REC

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

Grid-connected Inverters
For grid-connected photovoltaic systems of any size, our
offer includes suitable PV inverters from brand name
manufacturers. Whether single phase or three phase, with
or without transformers we are offering exclusively
equipment with maximum efciencies for high energy
yields over the long term.

SMA
KACO
KOSTAL
SAMIL POWER

31

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

SMA Sunny Boy


Flexible pioneers

32

As the rst manufacturer of an inverter suitable for


mass production, SMA has concentrated on repeatedly
diversifying the implementation possibilities with new
technologies, so that today any system constellation
from 400 Wp and upwards can be optimally realized
with an SMA inverter. SMA develops and manufactures
the inverters for a life span of more than 20 years and
produces at the company headquarters in Niestetal,
near Kassel, Germany.

The choice is yours: with or without transformer

SMA inverters are available with or without transformers. While the transformerless concept offers the ability to use such latest technologies as H5 topology and is
also extremely lightweight, the transformer device is
the rst choice for those who want galvanic isolation.
In addition, transformer-based devices offer the best
possibilities for combination with thinlm modules.

A new generation of electrically isolated inverters: Full of


state-of-the-art SMA technology, the Sunny Boy HF delivers
the highest yields for inverters with transformers of this
performance class.

The new generation: globally communicative

Just radio where previously cables were required


Bluetooth makes it possible. The Sunny Boys of the
new generation are provided with this innovative
radio technology. Set for international action: the
new Sunny Boy speaks German, English, French, Spanish, Italian, and Greek.

Easy installation of the new Sunny Boy

In addition to its completely new installation and wiring concept, the new Sunny Boy is not only 20 percent
lighter, it is also clearly reduced in volume. Installation
in a ash on a top hat rail or wall xture is thus
guaranteed. The concept is rounded off by wiring without tools due to special SMA spring-type clamps and
effective anti-theft device.

The new generation of the Sunny Boy series: with Bluetooth


and exible country settings as standard.

...................................................................................................................................................................
Single-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201741

0201539

0201018

0201742

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type

SMA SB 1300TL-10
125 - 480 V
600 V
11 A
1300 W
1400 W
1 pc.
180 - 260 V
1
50 Hz -4.5 Hz, +2.5 Hz
96.0 %
94.3 %
0.1 W
-25 to +60 C
IEC 60721-3-4, 4K4H
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
LC display
Aluminium
440 mm / 339 mm / 214 mm
16 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, UTE C15-712-1,
VDE-AR-N 4105, RD1699

SMA SB 1600TL-10
155 - 480 V
600 V
11 A
1600 W
1700 W
1 pc.
180 - 260 V
1
50 Hz -4.5 Hz, +2.5 Hz
96.0 %
95.0 %
0.1 W
-25 to +60 C
IEC 60721-3-4, 4K4H
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
LC display
Aluminium
440 mm / 339 mm / 214 mm
16 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, UTE C15-712-1,
VDE-AR-N 4105, RD1699

SMA SB 2100TL-10
200 - 480 V
600 V
11 A
1950 W
2200 W
1 pc.
180 - 260 V
1
50 Hz -4.5 Hz, +2.5 Hz
96.0 %
95.2 %
0.1 W
-25 to +60 C
IEC 60721-3-4, 4K4H
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
LC display
Aluminium
440 mm / 339 mm / 214 mm
16 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, UTE C15-712-1,
VDE-AR-N 4105, RD1699

SMA SB 2500TLST21
180 - 500 V
750 V
15 A
2500 W
2650 W
1 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.0 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
23 kg
5 years
CE mark, VDE 0126-1-1, G83/11, C10/11, G59/2, VDE-AR-N
4105

Art. No.

0201743

0201583

0201744

0201584

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type

SMA SB 3000TLST21
213 - 500 V
750 V
15 A
3000 W
3200 W
1 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.1 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
23 kg
5 years
CE mark, VDE 0126-1-1, G83/11, C10/11, G59/2, VDE-AR-N
4105

SMA SB 3000TL-21
175 - 500 V
750 V
2 x 15 A
3000 W
3200 W
2 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.0 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
26 kg
5 years
CE mark, VDE 0126-1-1,
C10/11, VDE-AR-N 4105

SMA SB 3600TL-21
175 - 500 V
750 V
2 x 15 A
3680 W
3880 W
2 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.3 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
26 kg
5 years
CE mark, VDE 0126-1-1,
C10/11, VDE-AR-N 4105

SMA SB 4000TL-21
175 - 500 V
750 V
2 x 15 A
4000 W
4200 W
2 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.4 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
26 kg
5 years
CE mark, VDE 0126-1-1,
C10/11, VDE-AR-N 4105

Grid monitoring
Fault current monitoring
Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Grid monitoring
Fault current monitoring
Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

33

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

34

Art. No.

0201585

0201118

0201119

0201120

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type

SMA SB 5000TL-21
175 - 500 V
750 V
2 x 15 A
4600 W
5300 W
2 pc.
180 - 280 V
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
97.0 %
96.5 %
1.0 W
-25 to +60 C
0 to 100 %, no condensation
Convection
IP65
Transformerless, singlephased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
490 mm / 519 mm / 185 mm
26 kg
5 years
CE mark, VDE 0126-1-1,
C10/11, VDE-AR-N 4105

SMA SB 2000HF-30
175 - 560 V
700 V
12 A
2000 W
2100 W
1 pc.
180 - 280 V
1
50 Hz 4.5 Hz
96.3 %
95.0 %
1.0 W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
High frequency transformer,
single-phased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
348 mm / 580 mm / 145 mm
17 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, IEC 61727,
SI4777, UTE C15-712-1, VDEAR-N 4105, RD1699

SMA SB 2500HF-30
175 - 560 V
700 V
15 A
2500 W
2600 W
1 pc.
180 - 280 V
1
50 Hz 4.5 Hz
96.3 %
95.3 %
1.0 W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
High frequency transformer,
single-phased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
348 mm / 580 mm / 145 mm
17 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, IEC 61727,
SI4777, UTE C15-712-1, VDEAR-N 4105, RD1699

SMA SB 3000HF-30
210 - 560 V
700 V
15 A
3000 W
3150 W
1 pc.
180 - 280 V
1
50 Hz 4.5 Hz
96.3 %
95.4 %
1.0 W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
High frequency transformer,
single-phased
Yes
Fault current monitoring
according to VDE 0126
Graphic LC display
Aluminium
348 mm / 580 mm / 145 mm
17 kg
5 years
CE mark, VDE 0126-1-1, G83/11, PPC, AS 4777, EN 50438,
C10/11, PPDS, IEC 61727,
SI4777, UTE C15-712-1, VDEAR-N 4105, RD1699

Grid monitoring
Fault current monitoring
Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

* - Can optionally be extended to 10 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

35

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

Kaco Powador 00 Series


Inverters without transformers
Higher efciency

36

Without transformers, the inverters of the Kaco 00


series achieve optimal efciency. As a specialist for
inverters without transformers, Kaco has equipped all
devices of the 00 series with a full bridge and omitted
the boost converters. The self-controlled devices emulate the sinus voltage curve of the public power grid
using a H4 bridge. Prerequisite for using the 00 series
inverters is an input voltage higher than the grid peak
voltage.

rent-operated protective device, facilitates the grid


connection, even in the case of systems with several
inverters.

Long service life

All inverters operate up to outputs of 8 kW with silent


and purely passive cooling. The lost heat is optimally
dissipated by the cooling element on the back. This
cooling without mechanical fans reduces error sources
and thus achieves a long life-cycle of the devices.

Simple installation

100 % feed-in

The Powador 3200 5500 without transformers can be single-phase connected individually, due to their nominal output.

The single-phase Powador 6600 9600 have a nominal output of more than 5 kW; for this reason the unbalanced load
between feed-in phases should be considered during the
dimensioning.

With a MPP range of 350 to 600 V and an off-load


voltage of 800 V the conditions for a simple system
dimensioning are ideal. The devices are connected to
the grid by screw terminals. The redundant 3-phase
monitoring, including an AC/DC sensitive residual-cur-

The Kaco Powador 7900 was specically developed for


applications with connections limits of 20 kW. Due to
the 100 % symmetrical feed-in of 20 kW, not one watt
of power is wasted, not even in Spain, Italy or Greece.

...................................................................................................................................................................
Single-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201462

0201463

0201464

0201465

0201466

Model

Kaco Powador 3200


DCS INT
350 - 600 V
800 V
8.6 A
2600 W
3200 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.6 %
95.8 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:200602, VDE AR-N 4105
Two-line LC display
PCB clip up to max.
10 mm
Aluminium
500 mm / 340 mm /
200 mm
19 kg
10 years
DIN VDE 0126-1-1:200602, EN 50178, DIN EN
50178, IEC 62103, RAL
seal of approval (RAL
GZ 966), VDE AR-N 4105

Kaco Powador 4400


DCS INT
350 - 600 V
800 V
12.0 A
3600 W
4400 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.5 %
95.9 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:200602, VDE AR-N 4105
Two-line LC display
PCB clip up to max.
10 mm
Aluminium
550 mm / 340 mm /
220 mm
21 kg
10 years
DIN VDE 0126-1-1:200602, EN 50178, DIN EN
50178, IEC 62103, RAL
seal of approval (RAL
GZ 966), VDE AR-N 4105

Kaco Powador 5300


DCS INT
350 - 600 V
800 V
14.5 A
4400 W
5300 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.4 %
95.8 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:200602, VDE AR-N 4105
Two-line LC display
PCB clip up to max.
10 mm
Aluminium
550 mm / 340 mm /
220 mm
26 kg
10 years
DIN VDE 0126-1-1:200602, EN 50178, DIN EN
50178, IEC 62103, RAL
seal of approval (RAL
GZ 966), VDE AR-N 4105

Kaco Powador 5500


DCS INT
350 - 600 V
800 V
15.2 A
4600 W
5500 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.3 %
95.7 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:200602, VDE AR-N 4105
Two-line LC display
PCB clip up to max.
10 mm
Aluminium
600 mm / 340 mm /
220 mm
28 kg
10 years
DIN VDE 0126-1-1:200602, EN 50178, DIN EN
50178, IEC 62103, RAL
seal of approval (RAL
GZ 966), VDE AR-N 4105

Kaco Powador 6600


DCS INT
350 - 600 V
800 V
18.0 A
5500 W
6600 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.3 %
95.8 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:200602, VDE AR-N 4105
Two-line LC display
PCB clip up to max.
10 mm
Aluminium
600 mm / 340 mm /
220 mm
30 kg
10 years
DIN VDE 0126-1-1:200602, EN 50178, DIN EN
50178, IEC 62103, RAL
seal of approval (RAL
GZ 966), VDE AR-N 4105

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Grid monitoring
Display
Connection
Casing
Dimensions (W / H / D)
Weight
Warranty
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

37

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

38

Art. No.

0201467

0201468

0201469

0201470

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type

Kaco Powador 7700 DCS INT


350 - 600 V
800 V
19.0 A
6400 W
7700 W
1 pc.
190 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
96.6 %
96.2 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:2006-02,
VDE AR-N 4105
Two-line LC display
PCB clip up to max. 10 mm
Aluminium
810 mm / 340 mm / 220 mm
38 kg
10 years
DIN VDE 0126-1-1:2006-02, EN
50178, DIN EN 50178, IEC
62103, RAL seal of approval
(RAL GZ 966), VDE AR-N 4105

Kaco Powador 7900 DCS INT


350 - 600 V
800 V
19.7 A
6650 W
7900 W
1 pc.
190 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
96.7 %
96.2 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:2006-02,
VDE AR-N 4105
Two-line LC display
PCB clip up to max. 10 mm
Aluminium
810 mm / 340 mm / 220 mm
38 kg
10 years
DIN VDE 0126-1-1:2006-02, EN
50178, DIN EN 50178, IEC
62103, RAL seal of approval
(RAL GZ 966), VDE AR-N 4105

Kaco Powador 8600 DCS INT


350 - 600 V
800 V
21.4 A
7200 W
8600 W
1 pc.
190 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
96.6 %
96.2 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:2006-02,
VDE AR-N 4105
Two-line LC display
PCB clip up to max. 10 mm
Aluminium
810 mm / 340 mm / 220 mm
38 kg
10 years
DIN VDE 0126-1-1:2006-02, EN
50178, DIN EN 50178, IEC
62103, RAL seal of approval
(RAL GZ 966), VDE AR-N 4105

Kaco Powador 9600 DCS INT


350 - 600 V
800 V
24.0 A
8000 W
9600 W
1 pc.
190 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
96.6 %
96.2 %
0W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, transformerless
Integrated
DIN VDE 0126-1-1:2006-02,
VDE AR-N 4105
Two-line LC display
PCB clip up to max. 10 mm
Aluminium
810 mm / 340 mm / 220 mm
38 kg
10 years
DIN VDE 0126-1-1:2006-02, EN
50178, DIN EN 50178, IEC
62103, RAL seal of approval
(RAL GZ 966), VDE AR-N 4105

DC load disconnector
Grid monitoring
Display
Connection
Casing
Dimensions (W / H / D)
Weight
Warranty
Norms

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

39

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

Kaco Powador 02 Series


Great exibility, simple installation

40

New current sensor

Electrical isolation

Effortless installation

Advantages in brief

The new current sensor of the Kaco Powador 02 series


enables more precise control and better MPP tracking.
The inverters with electrical isolation satisfy with their
effortless installation, good efciency as well as optimal operation by means of thin-lm modules.

The connections are situated on their own PCB within


the casing and can be connected easily. For a faster and
easier wiring, all communication connections are
mounted separately on a PCB. A DC circuit breaker is
integrated into the device.

Due to the electrical isolation, the devices can be installed even in places that would be impossible for
devices without transformers. The wide input voltage
range makes the devices extremely exible and enables feed-in even at low irradiation.

n
n
n
n
n
n
n
n

The integrated transformer of the Powador 02 series ensures electrical isolation from the mains, which allows the
use of thin-lm modules without any problems.

International inverters for 16 countries


New current sensor
Electrical isolation
Simple installation
High efciency
Simple wiring
Optimal for thin-lm modules
Display of earthing status of the PV generator

With an efciency of 96 %, the inverters of the Kaco Powador 02 series are among the top-rated of their class.

...................................................................................................................................................................
Single-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201124

0201126

0201128

0201130

0201132

Model
MPP voltage range
Open circuit voltage *
Max. input current
Nominal output **
Max. DC power
MPP tracker
Output voltage
Power factor cos phi

Kaco Powador 2002 INT


125 - 510 V
600 V
14.3 A
1650 W
2000 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
95.9 %
95.3 %
0.4 W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, electrically isolated, HF
transformer
Integrated
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105
Two-line LC display,
LEDs
PCB clip up to max.
6 mm
Aluminium
450 mm / 340 mm /
200 mm
14.5 kg
10 years
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105, EN 50178,
DIN EN 50178, IEC
62103, RAL seal of
approval (RAL GZ 966),
G83

Kaco Powador 3002 INT


200 - 510 V
600 V
13.5 A
2500 W
3000 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
96.0 %
95.4 %
0.4 W
-20 to +60 C
Free convection / no fan
IP54
Self-controlled, electrically isolated, HF
transformer
Integrated
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105
Two-line LC display,
LEDs
PCB clip up to max.
6 mm
Aluminium
500 mm / 340 mm /
200 mm
20.0 kg
10 years
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105, EN 50178,
DIN EN 50178, IEC
62103, RAL seal of
approval (RAL GZ 966),
G83

Kaco Powador 4202 INT


200 - 510 V
600 V
18.5 A
3500 W
4200 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
95.9 %
95.1 %
0.4 W
-25 to +60 C
Free convection / no fan
IP54
Self-controlled, electrically isolated, HF
transformer
Integrated
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105
Two-line LC display,
LEDs
PCB clip up to max.
6 mm
Aluminium
600 mm / 340 mm /
240 mm
26.0 kg
10 years
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105, EN 50178,
DIN EN 50178, IEC
62103, RAL seal of
approval (RAL GZ 966),
G83

Kaco Powador 5002 INT


200 - 510 V
600 V
22.4 A
4200 W
5000 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
95.9 %
95.3 %
0.4 W
-25 to +60 C
Fan
IP54
Self-controlled, electrically isolated, HF
transformer
Integrated
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105
Two-line LC display,
LEDs
PCB clip up to max.
6 mm
Aluminium
600 mm / 340 mm /
240 mm
28.0 kg
10 years
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105, EN 50178,
DIN EN 50178, IEC
62103, RAL seal of
approval (RAL GZ 966),
G83

Kaco Powador 6002 INT


200 - 510 V
600 V
26.5 A
4600 / 5000 W
6000 W
1 pc.
190 - 264 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
95.9 %
95.3 %
0.4 W
-25 to +60 C
Fan
IP54
Self-controlled, electrically isolated, HF
transformer
Integrated
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105
Two-line LC display,
LEDs
PCB clip up to max.
6 mm
Aluminium
600 mm / 340 mm /
240 mm
28.0 kg
10 years
DIN VDE 0126-11:2006+E A1:2011, VDE
AR-N 4105, EN 50178,
DIN EN 50178, IEC
62103, RAL seal of
approval (RAL GZ 966),
G83

Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Grid monitoring
Display
Connection
Casing
Dimensions (W / H / D)
Weight
Warranty
Norms

* - Inverter starts only at voltages < 550 V for the protection of hardware
** - Art. No. 0201132: Depending on country setting

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

41

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Single-phased

...................................................................................................................................................................

Kostal Piko The single-phase All-in-One solution


Versatile application

42

With a generator power of 3 kW, the Kostal Piko


single-phase inverter is convincing not only for its exible range of applications in virtually all PV systems.
Transformerless conversion as well as the standard
integrated DC disconnect are just two of the numerous
features of the Piko series. Moreover, and in addition
to its high reliability, the inverter provides ease of
installation and a simplied country conguration.

Single-phase inverter

As single-phase inverter of the Piko series, Kostal Piko


3.0 offers many special equipment features. Already
integrated are the switch contact for own consumption
control, an electronic DC disconnect as well as a datalogger and web server for system monitoring. Additionally provided are standard interfaces such as

The single-phase Kostal inverter is transformerless and provided with an integrated datalogger.

RS485, S0, two Ethernet as well as four analogue inputs


allowing communications with other system components.

Advantages in brief
n
n
n
n

n
n

Transformerless conversion
Easy handling with grip depressions on the side
Broad input voltage range
Integrated switch contact for internal consumption
control
Integrated robust electronic DC switch
Integrated datalogger and web server for system
monitoring
Various communication interfaces integrated as a
standard
Graphic display with 3-button operating concept

The Piko sensor allows to compare actual irradiation and


temperature conditions with the performance data of the
PV system.

...................................................................................................................................................................
Single-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201884

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Relative humidity
Protection mode
Circuit type
DC load disconnector
Surge protection
Grid monitoring
Display
Connection (input / output)
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Kostal Piko 3.0


270 - 730 V
900 V
12.5 A
3000 W
4300 W
1 pc.
230 V
1, 0.9 inductive, 0.9 capacitive
50 Hz
96.20 %
95.50 %
< 1.7 W
-20 to +60 C
Controlled air cooling
0 to 95 %, no condensation
IP55
Transformerless, single-phased
Integrated
Integrated
DIN V VDE 0126-1-1, VDEW-compliant
Graphic display with 3-button operating concept
MC4 / spring-loaded terminal strip
Sheet steel
500 mm / 385 mm / 222 mm
22 kg
5 years
DIN VDE 0100-712, DIN EN 61000-3-2:2006, DIN EN 61000-6-3:2007, DIN V VDE V 0126-1-1 (VDE V 0126-1-1):2006-02, VDE-AR-N
4105, OVE/ONORM E 8001-4-712:2009-12, appendix A (AT), G83/1-1, G59/2

* - Can optionally be extended to 10 / 20 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

43

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

SMA Sunny Tripower Three-phase feed for


simple system planning
Greatest efciency

44

Cost-effective, safe and exible these qualities make


the SMA Sunny Tripower inverters extremely efcient
inverters. With an efciency of 98%, open circuit voltage up to 1000 V and power ratings of 5 to 20 kW, the
inverters are perfectly suited for all applications.

The latest technology

The innovative product qualities of the Sunny Tripower


series guarantee simple installation, high yields and
safe grid support. The multi-string technology and
the large input voltage range make the inverters ready
for all system dimensioning from 5 kW to the megawatt range.

fore a reliable part of the grid management. The safety


concept with string failure detection, electronic string
protection and integrable lightning protection function ensures greatest availability and reduces system
costs.

Advantages in brief
n
n
n

n
n
n
n

Best safety

Integrated DC circuit breaker ESS


String current monitoring
Flexible module dimensioning with two boost converters
Tool-free cable connection
Innovative DC connector system
Easily accessible connection area
Communication via Bluetooth

The Sunny Tripower inverters meet the requirements


of the VDEW Mean Voltage directives and are there-

The SMA Sunny Tripower efcient, innovative and safe.

Monitoring of system data with the SMA Sunny Beam.

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201748

0201749

0201750

0201751

0201752

Model
MPP voltage range
Open circuit voltage
Max. input current (Input A /
Input B)
MPP tracker
Nominal output
Max. DC power
Output voltage

STP 5000TL-20
245 - 800 V
1000 V
11 A / 10 A

STP 6000TL-20
295 - 800 V
1000 V
11 A / 10 A

STP 7000TL-20
290 - 800 V
1000 V
15 A / 10 A

STP 8000TL-20
330 - 800 V
1000 V
15 A / 10 A

STP 9000TL-20
370 - 800 V
1000 V
15 A / 10 A

2 pc.
5000 W
5100 W
160 - 280 V, threephased
1, 0.8 (leading) 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.1 %
1W
-25 to +60 C
0 to 100 %, no
condensation
OptiCool fan
IP65
Transformerless, threephased
Yes
Fault current
monitoring according
to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm /
240 mm
37 kg (approx.)
5 years
CE mark, VDE 0126-1-1,
UTE C15-712-1, VDE-ARN 4105

2 pc.
6000 W
6125 W
160 - 280 V, threephased
1, 0.8 (leading) 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.4 %
1W
-25 to +60 C
0 to 100 %, no
condensation
OptiCool fan
IP65
Transformerless, threephased
Yes
Fault current
monitoring according
to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm /
240 mm
37 kg (approx.)
5 years
CE mark, VDE 0126-1-1,
UTE C15-712-1, VDE-ARN 4105

2 pc.
7000 W
7175 W
160 - 280 V, threephased
1, 0.8 (leading) 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.5 %
1W
-25 to +60 C
0 to 100 %, no
condensation
OptiCool fan
IP65
Transformerless, threephased
Yes
Fault current
monitoring according
to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm /
240 mm
37 kg (approx.)
5 years
CE mark, VDE 0126-1-1,
UTE C15-712-1, VDE-ARN 4105

2 pc.
8000 W
8200 W
160 - 280 V, threephased
1, 0.8 (leading) 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.6 %
1W
-25 to +60 C
0 to 100 %, no
condensation
OptiCool fan
IP65
Transformerless, threephased
Yes
Fault current
monitoring according
to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm /
240 mm
37 kg (approx.)
5 years
CE mark, VDE 0126-1-1,
RD 661/2007, PPC, AS
4777, EN 50438,
C10/11, PPDS, UTE C15712-1, G59/2, VDE-AR-N
4105, BDEW 2008,
RD1699

2 pc.
9000 W
9225 W
160 - 280 V, threephased
1, 0.8 (leading) 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.6 %
1W
-25 to +60 C
0 to 100 %, no
condensation
OptiCool fan
IP65
Transformerless, threephased
Yes
Fault current
monitoring according
to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm /
240 mm
37 kg (approx.)
5 years
CE mark, VDE 0126-1-1,
UTE C15-712-1, VDE-ARN 4105

Power factor cos phi


Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Fault current monitoring
Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

45

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

46

Art. No.

0202118

0201111

0202119

0201112

Model
MPP voltage range
Open circuit voltage
Max. input current (Input A /
Input B)
MPP tracker
Nominal output
Max. DC power
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Fault current monitoring

STP 10000TL-20
370 - 800 V
1000 V
18 A / 10 A

STP 10000TL-10
320 - 800 V
1000 V
22 A / 11 A

STP 12000TL-20
370 - 800 V
1000 V
18 A / 10 A

STP 12000TL-10
380 - 800 V
1000 V
22 A / 11 A

2 pc.
10000 W
10250 W
160 - 280 V, three-phased
0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
98.0 %
97.6 %
1W
-25 to +60 C
0 to 100 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm / 240 mm
37 kg (approx.)
5 years
AS 4777, CE, CEI 0-21,
C10/11:2012, DIN EN 62109-1,
EN 50438, G59/3, G83/2, IEC
62109-2, NEN EN 50438, NRS
097-2-1, PPC, PPDS, RD
661/2007, RD 1699:2011, SI
4777, UTE C15-712-1, VDE
0126-1-1, VDE AR-N 4105, VFR
2013, VFR 2014

2 pc.
10000 W
10200 W
160 - 280 V, three-phased
1
50 Hz 5 Hz
98.1 %
97.7 %
<1W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 690 mm / 265 mm
65 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, BDEW 2008,
RD1699, CEI 0-21

2 pc.
12000 W
12275 W
160 - 280 V, three-phased
0.8 (leading) - 0.8 (lagging)
50, 60 Hz 5 Hz
98.2 %
97.9 %
1W
-25 to +60 C
0 to 100 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
470 mm / 730 mm / 240 mm
38 kg (approx.)
5 years
AS 4777, CE, CEI 0-21,
C10/11:2012, DIN EN 62109-1,
EN 50438, G59/3, G83/2, IEC
62109-2, NEN EN 50438, NRS
097-2-1, PPC, PPDS, RD
661/2007, RD 1699:2011, SI
4777, UTE C15-712-1, VDE
0126-1-1, VDE AR-N 4105, VFR
2013, VFR 2014

2 pc.
12000 W
12250 W
160 - 280 V, three-phased
1
50 Hz 5 Hz
98.1 %
97.7 %
<1W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 690 mm / 265 mm
65 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, BDEW 2008,
RD1699, CEI 0-21

Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201113

0201114

0201731

0201732

Model
MPP voltage range
Open circuit voltage
Max. input current (Input A /
Input B)
MPP tracker
Nominal output
Max. DC power
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Relative humidity
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Fault current monitoring

STP 15000TL-10
360 - 800 V
1000 V
33 A / 11 A

STP 17000TL-10
400 - 800 V
1000 V
33 A / 11 A

STP 15000TLEE-10
580 - 800 V
1000 V
36 A / -

STP 20000TLEE-10
580 - 800 V
1000 V
36 A / -

2 pc.
15000 W
15300 W
160 - 280 V, three-phased
1
50 Hz 5 Hz
98.2 %
97.7 %
<1W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 690 mm / 265 mm
65 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, BDEW 2008,
RD1699, CEI 0-21

2 pc.
17000 W
17400 W
160 - 280 V, three-phased
1
50 Hz 5 Hz
98.2 %
97.7 %
<1W
-25 to +60 C
0 to 98 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 690 mm / 265 mm
65 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, BDEW 2008,
RD1699, CEI 0-21

1 pc.
15000 W
15260 W
160 - 280 V, three-phased
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz -6 Hz, +5 Hz
98.5 %
98.3 %
1W
-25 to +60 C
0 to 100 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 680 mm / 265 mm
45 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, RD 1699, CEI
0-21

1 pc.
20000 W
20450 W
160 - 280 V, three-phased
1, 0.8 (leading) - 0.8 (lagging)
50, 60 Hz -6 Hz, +5 Hz
98.5 %
98.2 %
1W
-25 to +60 C
0 to 100 %, no condensation
OptiCool fan
IP65
Transformerless, three-phased
Yes
Fault current monitoring
according to VDE 0126
LCD graphics display
Aluminium
665 mm / 680 mm / 265 mm
45 kg (approx.)
5 years
CE mark, VDE 0126-1-1, RD
661/2007, PPC, AS 4777, EN
50438, C10/11, PPDS, IEC
61727, UTE C15-712-1, G59/2,
VDE-AR-N 4105, RD 1699, CEI
0-21

Display
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

* - Can optionally be extended to 10 / 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

47

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

Kaco Powador TL3 and TR3 series


Inverters from 5 to 17 kW
The latest technology

48

Kaco only uses state-of-the-art technology for the


manufacture of the new grid inverters of the TL3 and
TR3 series. The devices have extremely exible applications within a range of 5 to 17 kW and satisfy the
highest quality requirements. Real three-phase devices, they supply sinusoidal alternating current with a
phase shift of 120. The inverters meet all requirements
of the new low and mean voltage directive.

Powador TR3 series

The inverters with transformers of the TR3 series provide the best solution for systems in which electrical
isolation is required. Three strings can be connected
per DC input, which enables the connection of up to
nine strings. Three separate MPP trackers achieve the
optimal adjustment. The peak efciency is 96.2 %.

Other benets at a glance


n

Powador TL3 series

The transformerless inverters of the TL3 series operate


with two separate MPP trackers and can process solar
energy from up to four strings which can be completely
asymmetrically loaded. The input voltage range is designed particularly wide with 350 to 800 V. The start
voltage is already at 250 V, peak efciency is 98 %.

The transformerless inverters of the Powador TL3 series convince with the highest efciency of >98.0 %.

n
n

n
n
n
n

Cooling by temperature-controlled fans


RS485 interface for communication
Integrated web server for seamless monitoring via
Ethernet
USB interface for easy software updates
Graphic display to show the operating data
Simple installation due to compact housing
Asymmetrical dimensioning possible

The TR3 inverter series with transformers is particularly


suited to modules requiring grounding due to their electrical isolation.

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201298

0201299

0201300

0201250

Model
MPP voltage range *
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Grid monitoring
Display
Connection

Kaco Powador 6.0 TL3


200 - 800 V
1000 V
2 x 11.0 A
5000 W
6000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
97.8 %
96.3 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 7.8 TL3


200 - 800 V
1000 V
2 x 11.0 A
6500 W
7800 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
97.8 %
96.7 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 9.0 TL3


200 - 800 V
1000 V
2 x 11.0 A
7500 W
9000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
97.9 %
96.9 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 10.0 TL3


200 - 800 V
1000 V
2 x 18.6 A
9000 W
10000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
98.0 %
97.4 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Art. No.

0201251

0201252

0201301

0201302

Model
MPP voltage range *
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Grid monitoring
Display
Connection

Kaco Powador 12.0 TL3


200 - 800 V
1000 V
2 x 18.6 A
10000 W
12000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
98.0 %
97.5 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 14.0 TL3


200 - 800 V
1000 V
2 x 18.6 A
12500 W
14000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
98.0 %
97.6 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 18.0 TL3


200 - 800 V
1000 V
2 x 18.6 A
15000 W
18000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
98.0 %
97.7 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
40 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Kaco Powador 20.0 TL3


200 - 800 V
1000 V
2 x 18.6 A
17000 W
20000 W
2 pc.
400 / 230 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
97.9 %
97.6 %
1.5 W
-25 to +60 C
Temperature-controlled fan
IP65
Transformerless, three-phased
Integrated
DIN VDE 0126-1-1:2006-02
Graphic display & LED
MC4, AC screw connection
M40 and terminal
Aluminium
690 mm / 420 mm / 200 mm
44 kg (approx.)
7 years
DIN VDE V 0126-1-1:2006+E
A1:2011, VDE-AR-N 4105,
BDEW-MSR-compliant, CEI 021, C10/11 06.2012, G59/2,
G83/1, EN 50438

Casing
Dimensions (W / H / D)
Weight
Warranty **
Norms

Casing
Dimensions (W / H / D)
Weight
Warranty **
Norms

* - TL3 series: At voltages < 350 V, possible input power is reduced


Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

49

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

** - Can optionally be extended to 10 years

50

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

51

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

Kaco Powador central inverters


Efcient and reliable
Individual performance

52

With generator outputs of 25 to 1000 kW, the central


inverters of the Kaco Powador series cover an enormous performance range completely. The ability of
combining all devices freely enables any project to be
realised optimally and individually from single-family
houses to megawatt solar parks.

Powador TL3 series

Based on the concept of the successful 30 kW family


and the switching concept of the Powador 14.0 TL3,
these devices have been redesigned completely: As
three-phase devices they feed in between the phases
with a typical shift of 120. A number of country-specic presets are programmed into the inverters; simply
select the required ones on site on the devices. To
achieve optimal adjustment the devices operate three
separate MPP trackers, which can be loaded asymmetrically. The input voltage range is designed particularly
wide with 350 to 800 V.

Powador XP series

The central inverters of the Powador XP series are


leading with regard to user-friendliness and investment returns. The latest signal processor technology
provides highest performance, reliability and efciency. The completely digital control allows userfriendly operation and maintenance as well as extensive monitoring and communication options.

Advantages in brief
n
n
n
n

The transformerless three-phase current inverters of the


Powador TL3 series can be used internationally and are
extremely exible regarding their design.

Ability to combine all devices


Patented MPP control
New IGBT circuit breaker
3-phase voltage monitoring for devices without
transformers
Grid monitoring by means of BiSi for devices with
transformers
Integrated string collector with string fuse and
overvoltage protection (with Powador 30.0 72.0
TL3 XL variants)
Lowest kW price with Powador 60.0 and 72.0 TL3

The Kaco Powador Megawatt Station consists of three combined XP350-HV TL.

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201241

0201247

0201242

0201248

0201243

Model

Kaco Powador 30.0 TL3


M INT
350 - 800 V
1000 V
3 x 34 A
25000 W
30000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 30.0 TL3


XL INT
350 - 800 V
1000 V
3 x 34 A
25000 W
30000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 36.0 TL3


M INT
350 - 800 V
1000 V
3 x 34 A
30000 W
36000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 36.0 TL3


XL INT
350 - 800 V
1000 V
3 x 34 A
30000 W
36000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 39.0 TL3


M INT
350 - 800 V
1000 V
3 x 34 A
33300 W
39000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Display
DC load disconnector
Line fuses
Surge protection
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

53

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

54

Art. No.

0201249

0201284

0201285

0201286

0201287

Model

Kaco Powador 39.0 TL3


XL INT
350 - 800 V
1000 V
3 x 34 A
33300 W
39000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.0 %
<1W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 40.0 TL3


M INT
350 - 800 V
1000 V
3 x 34 A
36000 W
40000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.8 %
1.5 W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 40.0 TL3


XL INT
350 - 800 V
1000 V
3 x 34 A
36000 W
40000 W
3 pc.
400 / 230 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.8 %
1.5 W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, VDE-ARN 4105, IEC 621091:2010, EN 61000-61:2007, EN 61000-63:2007, EN 61000-312:2005, EN 61000-311:2000, EN 50438, CEI
0-21, C10/11 06.2012,
G59/2, G83/1

Kaco Powador 48.0 TL3


Park M INT
410 - 800 V
1000 V
3 x 34 A
40000 W
48000 W
3 pc.
480 / 277 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.8 %
1.5 W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, IEC
62109-1:2010, EN
61000-6-1:2007, EN
61000-6-3:2007, EN
61000-3-12:2005, EN
61000-3-11:2000

Kaco Powador 48.0 TL3


Park XL INT
410 - 800 V
1000 V
3 x 34 A
40000 W
48000 W
3 pc.
480 / 277 V
0.8 inductive,
0.8 capacitive
50 Hz
<3%
98.0 %
97.8 %
1.5 W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, threephased
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm /
355 mm
151 kg
5 years
DIN VDE 0126, IEC
62109-1:2010, EN
61000-6-1:2007, EN
61000-6-3:2007, EN
61000-3-12:2005, EN
61000-3-11:2000

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Display
DC load disconnector
Line fuses
Surge protection
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201288

Model

Kaco Powador 60.0 TL3 M INT Kaco Powador 60.0 TL3 XL INT Kaco Powador 72.0 TL3 Park
M INT
480 - 850 V
480 - 850 V
580 - 850 V
1000 V
1000 V
1000 V
3 x 36 A
3 x 36 A
3 x 36 A
49900 W
49900 W
60000 W
60000 W
60000 W
72000 W
3 pc.
3 pc.
3 pc.
400 / 230 V
400 / 230 V
480 / 277 V
0.8 inductive, 0.8 capacitive
0.8 inductive, 0.8 capacitive
0.8 inductive, 0.8 capacitive
50 Hz
50 Hz
50 Hz
<3%
<3%
<3%
98.0 %
98.0 %
98.0 %
97.8 %
97.8 %
97.8 %
1.5 W
1.5 W
1.5 W
-20 to +60 C
-20 to +60 C
-20 to +60 C
Forced cooling / speedForced cooling / speedForced cooling / speedcontrolled fan
controlled fan
controlled fan
IP54
IP54
IP54
Transformerless, three-phased Transformerless, three-phased Transformerless, three-phased
DIN V VDE 0126-1-1, VDEWDIN V VDE 0126-1-1, VDEWDIN V VDE 0126-1-1, VDEWcompliant
compliant
compliant
Graphic display & LED
Graphic display & LED
Graphic display & LED
Integrated
Integrated
Integrated
Integrated
Integrated
Sheet steel
Sheet steel
Sheet steel
840 mm / 1360 mm / 355 mm 840 mm / 1360 mm / 355 mm 840 mm / 1360 mm / 355 mm
173 kg
173 kg
173 kg
5 years
5 years
5 years
DIN VDE 0126, IEC 62109DIN VDE 0126, VDE-AR-N
DIN VDE 0126, VDE-AR-N
1:2010, EN 61000-6-1:2007, EN
4105, IEC 62109-1:2010, EN
4105, IEC 62109-1:2010, EN
61000-6-3:2007, EN 61000-361000-6-1:2007, EN 61000-661000-6-1:2007, EN 61000-612:2005, EN 61000-3-11:2000
3:2007, EN 61000-3-12:2005,
3:2007, EN 61000-3-12:2005,
EN 61000-3-11:2000, EN
EN 61000-3-11:2000, EN
50438, CEI 0-21, C10/11
50438, CEI 0-21, C10/11
06.2012, G59/2, G83/1
06.2012, G59/2, G83/1

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Display
DC load disconnector
Line fuses
Surge protection
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

0201289

0201290

0201291

Kaco Powador 72.0 TL3 Park


XL INT
580 - 850 V
1000 V
3 x 36 A
60000 W
72000 W
3 pc.
480 / 277 V
0.8 inductive, 0.8 capacitive
50 Hz
<3%
98.0 %
97.8 %
1.5 W
-20 to +60 C
Forced cooling / speedcontrolled fan
IP54
Transformerless, three-phased
DIN V VDE 0126-1-1, VDEWcompliant
Graphic display & LED
Integrated
Integrated
Integrated
Sheet steel
840 mm / 1360 mm / 355 mm
173 kg
5 years
DIN VDE 0126, IEC 621091:2010, EN 61000-6-1:2007, EN
61000-6-3:2007, EN 61000-312:2005, EN 61000-3-11:2000

* - Can optionally be extended to 10 / 15 / 20 years

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

55

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

56

Art. No.

0201234

0201192

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Harmonic distortion
Max. efciency
Euro efciency
Ambient temperature
Heat dissipation
Protection mode
Circuit type
Grid monitoring
Display
Casing
Dimensions (W / H / D)
Weight
Warranty
Norms

Kaco Powador 500 kW Station INT


450 - 830 V
1000 V
2 x 611 A
500000 W
600000 W
4 pc.
According to country-specic requirements
0.8 inductive, 0.8 capacitive
50 / 60 Hz
<3%
98.1 %
97.8 %
-20 to +50 C
Fan (max. 13000 m/h)
IP43
Digital control, transformerless
According to country-specic requirements
TFT LC display touch screen
Sheet steel
5600 mm / 3180 mm / 2700 mm
11000 kg (approx.)
5 years
EN 60950-1:2006, EN 50178:1997, EN 61000-6-1:2007, EN
61000-6-2:2005, EN 61000-6-4:2007, EN 61000-3-11:2000, EN
61000-3-12:2005, DIN VDE 0126-1-1:2006-02

Kaco Powador Megawatt Station INT


450 - 830 V
1000 V
3 x 856 A
1050000 W
1200000 W
4 pc.
According to country-specic requirements
0.8 inductive, 0.8 capacitive
50 / 60 Hz
<3%
98.3 %
98.0 %
-20 to +50 C
Fan (max. 18000 m/h)
IP24
Digital control, transformerless
According to country-specic requirements
TFT LC display touch screen
Sheet steel
7000 mm / 3000 mm / 3600 mm
52000 kg (approx.)
3 years
EN 60950-1:2006, EN 50178:1997, EN 61000-6-1:2007, EN
61000-6-2:2005, EN 61000-6-4:2007, EN 61000-3-11:2000, EN
61000-3-12:2005, DIN VDE 0126-1-1:2006-02

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

57

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

Samil Power Solar Lake Transformerless, gridconnected PV inverters


Efciency due to state-of-the-art technology

58

With its Solar Lake inverters, Samil Power offers threephase, grid-connected inverters at the highest technical level. Two independent MPP trackers enable the
transformerless devices to provide maximum power
yield with various orientations or in partial shade. Its
integrated control of inherent consumption and its
recording of environmental data, as well as performance reduction and reactive power control make the
Samil Power Solar Lake a highly efcient inverter with
a maximum efciency of 98 %.

Flexibility for different applications

The large input voltage range renders Solar Lake inverters extremely exible. Due to IP65, it can be used
indoors as well as outdoors; the light-weight housing
provides for ease of transportation as well as for a swift
and simple installation of the devices. A "plug and
play" connection for installation and maintenance,
the multi-lingual display, as well as the easy conguration for different country-specic grid standards
enable the device to be used in a multitude of applica-

The new Solar Lake TL-PM series offers a wide range from
5.5 to 30 kW.

tions. The standard integrated WiFi module wirelessly


transmits all relevant inverter data.

Designed for long-term operation

The inverters of the Solar Lake series are designed for


long-term operation. Accordingly, the devices have
already integrated the automatic protection against
overvoltage and undervoltage, against overload and
underload, against islanding and short-circuiting. For
all devices, the standard warranty is 10 years, which
may be extended for up to 25 years.

Characteristics at a glance
n

n
n
n
n
n

Maximum power yield thanks to two independent


MPP trackers
Maximum efciency of 98 %
High exibility thanks to a large input voltage range
Possible application indoors and outdoors
Fast and efcient installation and maintenance
Integrated protective equipment for a long service
life

The proven Solar Lake TL series from 10 to 17 kW.

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201882

0201883

0201885

0201886

0201887

Model

SAMIL POWER Solar


Lake SL5500TL-PM
450 - 800 V / 5000 W,
225 - 800 V / 2500 W
1000 V
11.5 A
5500 W
5750 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.00 %
97.20 %
0W
-25 to +60 C
Convection
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Aluminium
450 mm / 580 mm /
200 mm
24.0 kg
10 years
CE, TV, VDE 0126-1-1,
RD 1669, G83/2,
DK5940, EN 50178, EN
61000-3-2, EN 6100-61/2/3/4, IEC-62109, VDEAR-N-4105, CEI 0-21,
AS4777, CQC (6-10, 2530)

SAMIL POWER Solar


Lake SL7000TL-PM
450 - 800 V / 5000 W,
225 - 800 V / 2500 W
1000 V
11.5 A
7000 W
7400 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.00 %
97.50 %
0W
-25 to +60 C
Convection
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Aluminium
450 mm / 580 mm /
200 mm
24.0 kg
10 years
CE, TV, VDE 0126-1-1,
RD 1669, G83/2,
DK5940, EN 50178, EN
61000-3-2, EN 6100-61/2/3/4, IEC-62109, VDEAR-N-4105, CEI 0-21,
AS4777, CQC (6-10, 2530)

SAMIL POWER Solar


Lake SL8500TL-PM
450 - 800 V / 5000 W,
225 - 800 V / 2500 W
1000 V
11.5 A
8500 W
8900 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.00 %
97.50 %
0W
-25 to +60 C
Convection
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Aluminium
450 mm / 580 mm /
200 mm
24.0 kg
10 years
CE, TV, VDE 0126-1-1,
RD 1669, G83/2,
DK5940, EN 50178, EN
61000-3-2, EN 6100-61/2/3/4, IEC-62109, VDEAR-N-4105, CEI 0-21,
AS4777, CQC (6-10, 2530)

SAMIL POWER Solar


Lake SL10000TL-PM
450 - 800 V / 5000 W,
225 - 800 V / 2500 W
1000 V
11.5 A
10000 W
10350 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.00 %
97.60 %
0W
-25 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Aluminium
450 mm / 580 mm /
200 mm
24.0 kg
10 years
CE, TV, VDE 0126-1-1,
RD 1669, G83/2,
DK5940, EN 50178, EN
61000-3-2, EN 6100-61/2/3/4, IEC-62109, VDEAR-N-4105, CEI 0-21,
AS4777, CQC (6-10, 2530)

SAMIL POWER Solar


Lake SL10000TL
320 - 800 V

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Surge protection
Grid monitoring
Display
Connection
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

1000 V
16.0 A
10000 W
10400 W
2 pc.
400 / 230 V
1, 0.9 inductive,
0.9 capacitive
50 Hz
97.90 %
97.40 %
<5W
-20 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Sheet steel
520 mm / 716 mm /
230 mm
50.0 kg
10 years
CE, TV, BDEW, VDEAR-N 4105, VDE 0126-1,
G59, RD1663, DK5940,
CEI 0-21, CEI 0-16,
AS4777, ABNT CB-03,
EN 50178, EN 61000-3-2,
EN 6100-6-1/2/3/4, IEC62109

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

59

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

60

Art. No.

0201888

0201889

0201890

0201894

0201895

Model

SAMIL POWER Solar


Lake SL12000TL
380 - 800 V
1000 V
16.0 A
12000 W
12500 W
2 pc.
400 / 230 V
1, 0.9 inductive,
0.9 capacitive
50 Hz
97.90 %
97.40 %
<5W
-20 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Sheet steel
520 mm / 716 mm /
230 mm
50.0 kg
10 years
CE, TV, BDEW, VDEAR-N 4105, VDE 0126-1,
G59, RD1663, DK5940,
CEI 0-21, CEI 0-16,
AS4777, ABNT CB-03,
EN 50178, EN 61000-3-2,
EN 6100-6-1/2/3/4, IEC62109

SAMIL POWER Solar


Lake SL15000TL
380 - 800 V
1000 V
20.0 A
15000 W
15600 W
2 pc.
400 / 230 V
1, 0.9 inductive,
0.9 capacitive
50 Hz
98.00 %
97.60 %
<5W
-20 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Sheet steel
520 mm / 716 mm /
230 mm
50.0 kg
10 years
CE, TV, BDEW, VDEAR-N 4105, VDE 0126-1,
G59, RD1663, DK5940,
CEI 0-21, CEI 0-16,
AS4777, ABNT CB-03,
EN 50178, EN 61000-3-2,
EN 6100-6-1/2/3/4, IEC62109

SAMIL POWER Solar


Lake SL17000TL
430 - 800 V
1000 V
20.0 A
17000 W
17700 W
2 pc.
400 / 230 V
1, 0.9 inductive,
0.9 capacitive
50 Hz
98.00 %
97.60 %
<5W
-20 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
Amphenol
Sheet steel
520 mm / 716 mm /
230 mm
50.0 kg
10 years
CE, TV, BDEW, VDEAR-N 4105, VDE 0126-1,
G59, RD1663, DK5940,
CEI 0-21, CEI 0-16,
AS4777, ABNT CB-03,
EN 50178, EN 61000-3-2,
EN 6100-6-1/2/3/4, IEC62109

SAMIL POWER Solar


Lake SL25000TL-PM
440 - 800 V
1000 V
30.0 A
25000 W
26300 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.30 %
98.00 %
<5W
-25 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
MC4
Aluminium
600 mm / 880 mm /
239 mm
63.0 kg
10 years
CE, TV, BDEW, CEI 016, VDE 0126-1-1, RD
1669, G59, DK5940, EN
50178, EN 61000-3-2, EN
6100-6-1/2/3/4, IEC62109, VDE-AR-N-4105,
CEI 0-21, AS4777, CQC
(6-10, 25-30)

SAMIL POWER Solar


Lake SL30000TL-PM
460 - 800 V
1000 V
35.0 A
30000 W
32000 W
2 pc.
400 / 230 V
1, 0.8 inductive,
0.8 capacitive
50 / 60 Hz
98.40 %
98.00 %
<5W
-25 to +60 C
Fan
IP65
Transformerless, threephased
Optional
Integrated
DIN V VDE 0126-1-1,
VDEW-compliant
3.5 inch LCD
MC4
Aluminium
600 mm / 880 mm /
239 mm
63.0 kg
10 years
CE, TV, BDEW, CEI 016, VDE 0126-1-1, RD
1669, G59, DK5940, EN
50178, EN 61000-3-2, EN
6100-6-1/2/3/4, IEC62109, VDE-AR-N-4105,
CEI 0-21, AS4777, CQC
(6-10, 25-30)

MPP voltage range


Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Protection mode
Circuit type
DC load disconnector
Surge protection
Grid monitoring
Display
Connection
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

* - Can optionally be extended to 15 / 20 / 25 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

61

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

Kostal Piko The three-phase All-in-One solution


Versatile application

62

With a generator power between 3 and 10 kW, the


Kostal Piko series single-phase and three-phase inverters are convincing not only for their exible range of
applications in virtually all PV systems. Transformerless
conversion as well as the standard integrated DC disconnect are just two of the numerous features of the
Piko series. Moreover, and in addition to their high
reliability, the inverters provide ease of installation
and a simplied country conguration.

Three-phase inverters

With three-phase feed-in, the inverter models Kostal


Piko 4.2, Piko 5.5, Piko 7.0, Piko 8.3 and Piko 10.1
realize nominal outputs of up to 10 kW. Parallel connection allows an increase in maximum DC input current with all devices (except Piko 5.5). Moreover, Kostal
Piko 5.5 and Piko 10.1 are also provided with three
independent MPP trackers. All three-phase inverters
are provided with an integrated switch contact for

All three-phase Kostal inverters are transformerless and provided with an integrated datalogger.

own consumption measurement, an integrated electronic DC disconnect, a datalogger and web server for
system monitoring as well as the communication interfaces Ethernet, RS485, S0 and four analogue inputs.
Piko 7.0, Piko 8.3 and 10.1 are moreover equipped
with an additional Ethernet interface with integrated
switch for the direct connection of several inverters as
well as a graphics display. These three devices are also
optionally available with arc detection.

Advantages in brief
n
n
n
n
n
n
n

Versatile use
Three-phase feed-in already as low as 4.2 kW
Transformerless conversion
Integrated electronic DC disconnect
Effortless installation
Simple country conguration
Integrated datalogger and web server for system
monitoring

The Piko sensor allows to compare actual irradiation and


temperature conditions with the performance data of the
PV system.

...................................................................................................................................................................
Three-phased

GRID-CONNECTED INVERTERS

...................................................................................................................................................................

Art. No.

0201546

0201547

0201745

0201737

0201548

Model
MPP voltage range
Open circuit voltage
Max. input current
Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi

Kostal Piko 4.2 EU DCS


360 - 850 V
950 V
9.0 A
4200 W
4400 W
2 pc.
400 / 230 V
1, 0.95 inductive,
0.95 capacitive
50 Hz
96.50 %
95.40 %
<1W
-20 to +60 C
Controlled air cooling
0 to 95 %, no
condensation
IP55
Transformerless, threephased
Integrated
Type II / III
DIN V VDE 0126-1-1,
VDEW-compliant
Two-line LC display,
LEDs
MC4 / spring-loaded
terminal strip
Sheet steel
420 mm / 211 mm /
350 mm
20.5 kg
5 years
DIN VDE 0100-712, DIN
EN 61000-3-2:2006, DIN
EN 61000-6-3:2007, DIN
V VDE V 0126-1-1 (VDE
V 0126-1-1):2006-02,
VDE-AR-N 4105,
OVE/ONORM E 8001-4712:2009-12, appendix
A (AT), G83/1-1, G59/2

Kostal Piko 5.5 EU DCS


360 - 850 V
950 V
9.0 A
5500 W
5800 W
3 pc.
400 / 230 V
1, 0.95 inductive,
0.95 capacitive
50 Hz
96.20 %
95.70 %
<1W
-20 to +60 C
Controlled air cooling
0 to 95 %, no
condensation
IP55
Transformerless, threephased
Integrated
Type II / III
DIN V VDE 0126-1-1,
VDEW-compliant
Two-line LC display,
LEDs
MC4 / spring-loaded
terminal strip
Sheet steel
420 mm / 211 mm /
350 mm
21.1 kg
5 years
DIN VDE 0100-712, DIN
EN 61000-3-2:2006, DIN
EN 61000-6-3:2007, DIN
V VDE V 0126-1-1 (VDE
V 0126-1-1):2006-02,
VDE-AR-N 4105,
OVE/ONORM E 8001-4712:2009-12, appendix
A (AT), G83/1-1, G59/2

Kostal Piko 5.5 10A


360 - 850 V
950 V
10 A
5500 W
6000 W
2 pc.
184 - 264.5 V
0.9 inductive,
0.9 capacitive
50 Hz (2.5 Hz, +1.5 Hz)
96.20 %
95.70 %
< 2.7 W
-25 to +60 C
Controlled air cooling
0 to 95 %, no
condensation
IP55
Transformerless, threephased
Integrated
Type II / III
DIN V VDE 0126-1-1,
VDEW-compliant
Two-line LC display,
LEDs
MC4 / spring-loaded
terminal strip
Sheet steel
420 mm / 211 mm /
350 mm
21.1 kg
5 years
DIN VDE 0100-712, DIN
EN 61000-3-2:2006, DIN
EN 61000-6-3:2007, DIN
V VDE V 0126-1-1 (VDE
V 0126-1-1):2006-02,
VDE-AR-N 4105,
OVE/ONORM E 8001-4712:2009-12, appendix
A (AT), G83/1-1, G59/2

Kostal Piko 7.0 EU DCS


400 - 850 V
950 V
12.5 A
7000 W
7700 W
2 pc.
400 / 230 V
1, 0.95 inductive,
0.95 capacitive
50 Hz
96.00 %
95.30 %
<1W
-20 to +60 C
Controlled air cooling
0 to 95 %, no
condensation
IP55
Transformerless, threephased
Integrated
Type II / III
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic LC display

Kostal Piko 8.3 EU DCS


400 - 800 V
950 V
12.5 A
8300 W
8700 W
2 pc.
400 / 230 V
1, 0.95 inductive,
0.95 capacitive
50 Hz
97.00 %
96.30 %
<1W
-20 to +60 C
Controlled air cooling
0 to 95 %, no
condensation
IP55
Transformerless, threephased
Integrated
Type II / III
DIN V VDE 0126-1-1,
VDEW-compliant
Graphic LC display

MC4 / spring-loaded
terminal strip
Sheet steel
520 mm / 230 mm /
450 mm
33.0 kg
5 years
DIN VDE 0100-712, DIN
EN 61000-3-2:2006, DIN
EN 61000-6-3:2007, DIN
V VDE V 0126-1-1 (VDE
V 0126-1-1):2006-02,
VDE-AR-N 4105,
OVE/ONORM E 8001-4712:2009-12, appendix
A (AT), G83/1-1, G59/2

MC4 / spring-loaded
terminal strip
Sheet steel
520 mm / 230 mm /
450 mm
33.0 kg
5 years
DIN VDE 0100-712, DIN
EN 61000-3-2:2006, DIN
EN 61000-6-3:2007, DIN
V VDE V 0126-1-1 (VDE
V 0126-1-1):2006-02,
VDE-AR-N 4105,
OVE/ONORM E 8001-4712:2009-12, appendix
A (AT), G83/1-1, G59/2

Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Relative humidity
Protection mode
Circuit type
DC load disconnector
Surge protection
Grid monitoring
Display
Connection (input / output)
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

63

...................................................................................................................................................................
GRID-CONNECTED INVERTERS

Three-phased

...................................................................................................................................................................

64

Art. No.

0202073

0202064

0202065

0202066

Model
MPP voltage range
Open circuit voltage
Max. input current

Kostal Piko 10
290 - 800 V
1000 V
18 A / 18 A (symmetrical
dimensioning), 20 A / 10 A
(asymmetrical dimensioning)
10000 W
10800 W
2 pc.
185 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz (2.5 Hz, +1.5 Hz)
97.70 %
97.10 %
< 1.8 W
-25 to +60 C
Controlled air cooling
4 to 100 %, no condensation
IP55
Transformerless, three-phased
Integrated
Type II / III
DIN V VDE 0126-1-1, VDEWcompliant
Graphic LC display
MC4 / spring-loaded terminal
strip
Aluminium
580 mm / 445 mm / 248 mm
37.5 kg
5 years
DIN VDE 0100-712, DIN EN
61000-3-2:2006, DIN EN 610006-3:2007, DIN V VDE V 0126-11 (VDE V 0126-1-1):2006-02,
VDE-AR-N 4105, OVE/ONORM
E 8001-4-712:2009-12,
appendix A (AT), G83/1-1,
G59/2

Kostal Piko 12
290 - 800 V
1000 V
18 A / 18 A (symmetrical
dimensioning), 20 A / 10 A
(asymmetrical dimensioning)
12000 W
12900 W
2 pc.
185 - 264 V
0.8 inductive, 0.8 capacitive
50 Hz (2.5 Hz, +1.5 Hz)
97.70 %
97.10 %
< 1.8 W
-25 to +60 C
Controlled air cooling
4 to 100 %, no condensation
IP55
Transformerless, three-phased
Integrated
Type II / III
DIN V VDE 0126-1-1, VDEWcompliant
Graphic LC display
MC4 / spring-loaded terminal
strip
Aluminium
580 mm / 445 mm / 248 mm
37.5 kg
5 years
DIN VDE 0100-712, DIN EN
61000-3-2:2006, DIN EN 610006-3:2007, DIN V VDE V 0126-11 (VDE V 0126-1-1):2006-02,
VDE-AR-N 4105, OVE/ONORM
E 8001-4-712:2009-12,
appendix A (AT), G83/1-1,
G59/2

Kostal Piko 15
260 - 800 V
1000 V
20 A / 20 A / 20 A (symmetrical
and asymmetrical
dimensioning)
15000 W
16900 W
3 pc.
184 - 264.5 V
0.8 inductive, 0.8 capacitive
50 Hz (2.5 Hz, +1.5 Hz)
97.90 %
97.20 %
< 1.8 W
-25 to +60 C
Controlled air cooling
4 to 100 %, no condensation
IP55
Transformerless, three-phased
Integrated
Type II / III
DIN V VDE 0126-1-1, VDEWcompliant
Graphic LC display
MC4 / spring-loaded terminal
strip
Aluminium
700 mm / 540 mm / 265 mm
48.5 kg
5 years
DIN VDE 0100-712, DIN EN
61000-3-2:2006, DIN EN 610006-3:2007, DIN V VDE V 0126-11 (VDE V 0126-1-1):2006-02,
VDE-AR-N 4105, OVE/ONORM
E 8001-4-712:2009-12,
appendix A (AT), G83/1-1,
G59/2

Kostal Piko 17
295 - 800 V
1000 V
20 A / 20 A / 20 A (symmetrical
and asymmetrical
dimensioning)
17000 W
19200 W
3 pc.
184 - 264.5 V
0.8 inductive, 0.8 capacitive
50 Hz (2.5 Hz, +1.5 Hz)
98.00 %
97.30 %
< 2.15 W
-25 to +60 C
Controlled air cooling
4 to 100 %, no condensation
IP55
Transformerless, three-phased
Integrated
Type II / III
DIN V VDE 0126-1-1, VDEWcompliant
Graphic LC display
MC4 / spring-loaded terminal
strip
Aluminium
700 mm / 540 mm / 265 mm
48.5 kg
5 years
DIN VDE 0100-712, DIN EN
61000-3-2:2006, DIN EN 610006-3:2007, DIN V VDE V 0126-11 (VDE V 0126-1-1):2006-02,
VDE-AR-N 4105, OVE/ONORM
E 8001-4-712:2009-12,
appendix A (AT), G83/1-1,
G59/2

Nominal output
Max. DC power
MPP tracker
Output voltage
Power factor cos phi
Frequency
Max. efciency
Euro efciency
Night-time consumption
Ambient temperature
Heat dissipation
Relative humidity
Protection mode
Circuit type
DC load disconnector
Surge protection
Grid monitoring
Display
Connection (input / output)
Casing
Dimensions (W / H / D)
Weight
Warranty *
Norms

* - Can optionally be extended to 10 / 20 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

65

GRID-CONNECTED INVERTERS Special products Switzerland

SolarMax Inverters
From Switzerland, for Switzerland

66

Swiss quality

MT series clever multi-tracking

Quality has top priority: All inverters are tested according to current product safety standards and are
provided with the TV quality seal Bauart geprft
(Design tested). Development, production and all
quality controls take place in Switzerland.

PV systems with inverters of the SolarMax MT series use roof areas more efficiently yet. Thanks to
an innovative and flexible multi-tracking concept,
the operating point of individual module arrays is
individually adjusted and thus optimized. During its
installation already, the solar generator can be specifically subdivided to also minimize performance
losses which may result due to temporary shading.

Maximum return
Investments in SolarMax inverters are risk-free. The
solidly built high-quality devices have a long service
life and, due to their consistently high yield, get the
maximum out of any solar system. A profitable investment.

Single-phase and three-phase string inverters with nominal outputs between 1.8 and 15 kW are designed for small
and medium-sized solar power systems.

SolarMax central inverters are convincing due to their


compact design, flexibility and their excellent price/benefit ratio.

Special products Switzerland GRID-CONNECTED INVERTERS

P series single-phase string inverters (2 5 kW)


The P series inverters were designed specifically for roof-mounted systems on
residential buildings. Along with high efficiencies of up to 98 %, they are characterised by simple and, thus, time- and cost-saving installation and commissioning, as well as customised configuration options. The P series inverters are real
powerhouses and can be operated in single- or dual-tracker mode.

MT series three-phase string inverters (6 15 kW)


Three-phase feeding inverters of high efficiency. The MT series string inverters
are suitable for medium-sized house systems already; however, their range of
application extends even to industrial large-scale projects. Thanks to the multitracking concept, different angles of inclination and orientations present no
problem.

TS series three-phase central inverters (50 300 kW)


The TS series is a systematic further development of the proven C series. Maximum energy yields and utmost flexibility devices of this series are set for the
future.

TS-SV three-phase central inverters (360 kW)


The SolarMax 360TS-SV inverter is the best selection for PV installations which
are directly connected to the medium-voltage grid. Thanks to the systematic use
of film capacitors and the intelligent monitoring of power semi-conductors, this
inverter is particularly durable and reliable.

SolarMax inverters from the TRITEC product range are exclusively available for Switzerland.
Further information about SolarMax inverters: www.solarmax.ch

TRITEC Group www.tritec-energy.com | 20140211-1 | The content of this datasheet is subject to change without prior notice

67

Control and Measuring


Instruments
Only regular maintenance and monitoring will guarantee
long-term high yields of a PV system. In addition to
dataloggers and displays, we also offer own products in
the area of measuring technology: The characteristics
analyser TRI-KA will measure fast and simply the
current/voltage curve of module strings and individual
modules. Our sensors measure not only the outside
temperature, but also the module temperature and thus
improve the measuring results of a datalogger.

TRITEC
SOLAR-LOG
4-NOKS
SOLARFOX

69

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Characteristics Analyser

...................................................................................................................................................................

TRI-KA The mobile characteristics analyser: Now


even more efcient
Mobile portable measuring instrument

70

The new TRIKA not only identies the current voltage


curves of module strings, but also of individual photovoltaic modules. The I-U characteristic curve, output,
short-circuit current and open-circuit voltage are
recorded by a 16 bit processor. During each measurement the TRIKA adjusts the measuring range and
sample rate optimally. The device is easily and intuitively operated using the menus on the colour touch
screen. The characteristic curve measured by the
TRIKA can be converted to a STC characteristic curve
based on the values measured by the sensor TRISEN
and displayed. In addition, the STC ideal characteristic
curve of the manufacturer can be displayed, due to the
integrated module data base.

measuring of the irradiation can be either a monocrystalline or a polycrystalline cell.

Evaluation software

The evaluation software was also completely overhauled. The TRIKA software can evaluate, manage
and store the measured module data on the PC. With
a few steps of the guided Wizard, the measured data is
saved to the respective customer or system directory.
Further measurements of the same system can then be
added, sorted by date, and compared with the software.

Advantages in brief
n
n

Wireless sensor

Without contact, the wireless sensor TRISEN measures


the cell temperature, the angle of inclination and the
irradiation at the solar module level. The measured
values are wirelessly transferred directly to the main
instrument, the TRIKA. The reference cell for the

The TRIKA characteristics analyser and the TRISEN irradiation and temperature sensor are easy to operate and provide reliable measurements.

n
n
n
n
n

Mobile portable measuring instrument


Wireless sensor
Simple menu navigation on colour touch screen
Large measuring range: 1.0 1000 V and 0.1 15.0 A
Creation of system and maintenance protocols
Output comparison for several years
Simple identication of errors and faults of PV systems and PV modules

With the evaluation software the individual strings are evaluated and combined to individual installations. Measurement reports from single strings, single modules and from
the entire systems can be printed.

...................................................................................................................................................................
Characteristics Analyser

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802201

Model
Included in delivery

TRI-KA complete set


1 TRIKA, 1 TRISEN, 1 rugged case with rubber foam padding, TRIKA measurement cable sets (MC3, MC4, Huber+Suhner, Tyco,
SunClix and without connectors), 1 TRISEN mounting, 1 SD card (PC user software with user guide), 1 USB SD/SDHC card reader,
2 power supply units (chargeable), operating instructions

Specications

71
Model
Measuring

TRI-KA
I/U characteristic curve, short-circuit current, open-circuit
voltage, MPP current, MPP voltage
Calculated values
STC values (short-circuit current, open-circuit voltage, MPP
current, MPP voltage), ll factor, MPP output, ideal
characteristic curve of module manufacturer
Voltage measuring range
1.0 - 1000 V (< 1 %) (Uoc > 5 V)
Current measuring range
0.1 - 15.0 A (< 1 %)
Temperature measuring range Irradiation measuring range
Measuring connection
Measuring cable
Characteristic curve measuring 15 - 30 seconds
duration
Save slots for measured curves Depending on size of SD memory card (> 1000 measured
curves with 1 GB)
Reference cells
Display
3.2 inch colour LCD touch screen (240 x 320 pixels, RGB)
Power supply
Lithium polymer accumulator, run-time app. 8 hours
Auto power-off
Adjustable (1 - 15 minutes)
Interface
2 measuring cables to PV string, wireless connection to
TRISEN, SD/SDHC memory card for PC
Ambient temperature
0 to +50 C
Protection mode
IP20
Insulation
Protection class II
Measuring category
CAT II 1000 V, CAT III 600 V
Dimensions (L / W / H)
210 mm / 105 mm / 41 mm
Weight
500 g
Warranty
2 years
Norms
EN 61010-1, EN 61010-2-030, EN 61010-031, CE mark
Spare parts
Art. No.
0801101
0801102
0801103
0801104
0801110
0802202
0802203
0802205
0802206
0802208
0802209

Model
TRI-KA measurement cable replacement set for MC3
TRI-KA measurement cable replacement set for MC4
TRI-KA measurement cable replacement set for
Huber+Suhner
TRI-KA measurement cable replacement set for Tyco
TRI-KA measurement cable replacement set without
connector
TRI-SEN mounting
TRI-KA measurement cable replacement set for
SunClix
TRI-KA SD/SDHC card reader
TRI-KA SD/SDHC memory card
TRI-KA rugged case, empty
TRI-KA chargeable power supply unit

TRI-SEN
Global irradiation, module temperature, angle of inclination
0 - 100 C (3 % in relation to a black body)
100 - 1200 W/m (5 %)
Non-contact measurement
1 x monocrystalline cell, 1 x polycrystalline cell
B/W LC display (2-line, 16 characters)
Lithium polymer accumulator, run-time app. 8 hours
Wireless connection to TRIKA
0 to +60 C
IP20
160 mm / 82 mm / 41 mm
200 g
2 years
EN 61010-1, CE mark

Belongs to Art. No.


0802201
0802201
0802201
0802201
0802201
0802201
0802201
0802201
0802201
0802201
0802201

For measurements of (certain) thin-layer modules and special module technologies, please consult TRITEC.
System requirements user software: Microsoft Windows XP / Vista / 7; Pentium processor with a minimum of 600 MHz or similar; minimum of 256 MB
memory or more; VGA graphics card with at least 16 bit colour depth (High Color) and a resolution of 1024 x 768 pixels; free hard disc memory of at least
500 MB; keyboard; mouse; USB interface

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Datalogger

...................................................................................................................................................................

The Solar-Log series The monitoring system for


all photovoltaic systems
State-of-the-art technology

72

The devices of the Solar-Log series provide simple monitoring of solar systems of all types. Due to state-ofthe-art technology, the operation, analysis and display
of all parameters are handled by the web browser. And
the web browser is independent of the operating system.

Great exibility

Various interfaces allow the connection and analysis of


all current inverters. The Solar-Log series is a manufacturer-independent complete solution, which provides
all tools for the professional monitoring and analysis of
solar systems.

The new Solar-Log300, Solar-Log1200 and Solar-Log2000 are


multilingual and can be connected to almost any inverter
during installation.

Features
n
n

n
n
n
n
n

String monitoring
Monitoring of failure and performance of individual
inverters
Status and fault monitoring via integrated LCD display
Completely internet-enabled; sends messages via email and SMS
Existing broadband router can also be used
S0 output for large displays
S0 input for electric meter
USB port for simple data transfer
Connection of Solar-Log SensorBox or Sensor basic
for the recording of environmental data

Solar-LogTM Web offers the perfect display of all data of a


photovoltaic system.

...................................................................................................................................................................
Datalogger

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802273

0802274

0802275

0802276

0802277

Model
Number of inverters
Number of inverter
manufacturers
Software conguration
Recommended max. system
size
Max. cable length
Voltage (Supply / Device)
Power consumption
Ambient temperature
Protection mode
Casing
Display
Interface

Solar-Log 300

Solar-Log 300 WiFi


Any
1

Solar-Log 300 BT, SMA


Bluetooth
Any
1

Solar-Log 300 WiFi BT,


SMA Bluetooth
Any
1

Solar-Log 300 GPRS

Any
1
Flexible
15 kWp

Flexible
15 kWp

Flexible
15 kWp

Flexible
15 kWp

Flexible
15 kWp

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display
1 x Ethernet - RJ45 bush
- 10/100 MBit,
1 x RS485/RS422, 1 x USB,
2 x S0-In

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display
1 x Ethernet - RJ45 bush
- 10/100 MBit,
1 x RS485/RS422, 1 x USB,
2 x S0-In, WiFi

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display
1 x Ethernet - RJ45 bush
- 10/100 MBit,
1 x RS485/RS422, 1 x USB,
2 x S0-In, Bluetooth

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display
1 x Ethernet - RJ45 bush
- 10/100 MBit,
1 x RS485/RS422, 1 x USB,
2 x S0-In, GPRS

Weight
Warranty

Via web browser


Multi-lingual
Integrated web server
225 mm / 285 mm /
40 mm
0.80 kg
5 years

Via web browser


Multi-lingual
Integrated web server
225 mm / 285 mm /
40 mm
0.80 kg
5 years

Via web browser


Multi-lingual
Integrated web server
225 mm / 285 mm /
40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display
1 x Ethernet - RJ45 bush
- 10/100 MBit,
1 x RS485/RS422, 1 x USB,
2 x S0-In, Bluetooth,
WiFi
Via web browser
Multi-lingual
Integrated web server
225 mm / 285 mm /
40 mm
0.80 kg
5 years

Via web browser


Multi-lingual
Integrated web server
225 mm / 285 mm /
40 mm
0.80 kg
5 years

Art. No.

0802278

0802279

0802280

0802281

0802282

Model

Solar-Log 300 PM+,


Power Management

Solar-Log 300 Meter

Solar-Log 1200

Number of inverters
Number of inverter
manufacturers
Software conguration
Recommended max. system
size
Max. cable length
Voltage (Supply / Device)
Power consumption
Ambient temperature
Protection mode
Casing
Display

Any
1

Solar-Log 300 PM+ WiFi, Solar-Log 300 PM+


Power Management
GPRS, Power
Management
Any
Any
1
1

Any
1

Any
2

Flexible
15 kWp

Flexible
15 kWp

Flexible
15 kWp

Flexible
15 kWp

Flexible
100 kWp

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display

Handling
Languages
Data interpretation
Dimensions (L / W / H)

Interface

Handling
Languages
Data interpretation
Dimensions (L / W / H)
Weight
Warranty

Any
1

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display,
graphic display with
touch screen
1 x Ethernet - RJ45 bush 1 x Ethernet - RJ45 bush 1 x Ethernet - RJ45 bush 1 x Ethernet - RJ45 bush 1 x RS485/RS422,
1 x RS485, 1 x Ethernet - 10/100 MBit,
- 10/100 MBit,
- 10/100 MBit,
- 10/100 MBit,
1 x RS485/RS422, 1 x USB, 1 x RS485/RS422, 1 x USB, 1 x RS485/RS422, 1 x USB, 1 x RS485/RS422, 1 x USB, RJ45 bush - 10/100 MBit,
1 x USB, 2 x S0-In,
2 x S0-In, 1 x external
2 x S0-In, WiFi, input for 2 x S0-In, GPRS, input
2 x S0-In, input for
1 x potential-free
for ripple control signal, meter current
ripple control signal,
ripple control signal,
contact (relay)
compatibility of power compatibility of power compatibility of power transformer
management with
management with
management with
inverter types on
inverter types on
inverter types on
request
request
request
Via web browser
Via web browser
Via web browser
Via web browser
Via web browser and
touch screen display
Multi-lingual
Multi-lingual
Multi-lingual
Multi-lingual
Multi-lingual
Integrated web server Integrated web server Integrated web server Integrated web server Integrated web server
225 mm / 285 mm /
225 mm / 285 mm /
225 mm / 285 mm /
225 mm / 285 mm /
225 mm / 285 mm /
40 mm
40 mm
40 mm
40 mm
40 mm
0.80 kg
0.80 kg
0.80 kg
0.80 kg
0.80 kg
5 years
5 years
5 years
5 years
5 years

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

73

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Datalogger

...................................................................................................................................................................

74

Art. No.

0802283

0802284

0802285

0802286

Model

Solar-Log 1200 WiFi


Any
2

Solar-Log 1200 BT, SMA


Bluetooth
Any
2

Solar-Log 1200 WiFi BT, SMA


Bluetooth
Any
2

Solar-Log 1200 GPRS

Number of inverters
Number of inverter
manufacturers
Software conguration
Recommended max. system
size
Max. cable length
Voltage (Supply / Device)
Power consumption
Ambient temperature
Protection mode
Casing
Display

Any
2

Flexible
100 kWp

Flexible
100 kWp

Flexible
100 kWp

Flexible
100 kWp

Languages
Data interpretation
Dimensions (L / W / H)
Weight
Warranty

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), WiFi
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), Bluetooth
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), WiFi, Bluetooth
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), GPRS
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

Art. No.

0802287

0802288

0802289

0802290

Model

Solar-Log 1200 PM+, Power


Management
Any
2

Solar-Log 1200 PM+ WiFi,


Power Management
Any
2

Solar-Log 1200 PM+ GPRS,


Power Management
Any
2

Solar-Log 1200 Meter


Any
2

Flexible
100 kWp

Flexible
100 kWp

Flexible
100 kWp

Flexible
100 kWp

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), input for ripple control
signal, compatibility of power
management with inverter
types on request
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), WiFi, input for ripple
control signal, compatibility of
power management with
inverter types on request
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), GPRS, input for ripple
control signal, compatibility of
power management with
inverter types on request
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
1 x RS485/RS422, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), input for ripple control
signal, 1 x external meter
current transformer

Interface

Handling

Number of inverters
Number of inverter
manufacturers
Software conguration
Recommended max. system
size
Max. cable length
Voltage (Supply / Device)
Power consumption
Ambient temperature
Protection mode
Casing
Display
Interface

Handling
Languages
Data interpretation
Dimensions (L / W / H)
Weight
Warranty

Via web browser and touch


screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
Datalogger

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802291

0802292

0802293

0802294

Model

Solar-Log 2000

Solar-Log 2000 GPRS

Number of inverters
Number of inverter
manufacturers
Software conguration
Recommended max. system
size
Max. cable length
Voltage (Supply / Device)
Power consumption
Ambient temperature
Protection mode
Casing
Display

Any
3

Any
3

Solar-Log 2000 PM+, Power


Management
Any
3

Solar-Log 2000 PM+ GPRS,


Power Management
Any
3

Flexible
2000 kWp

Flexible
2000 kWp

Flexible
2000 kWp

Flexible
2000 kWp

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
2 x RS485 / 1 x CAN, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), 1 x alarm contact

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
2 x RS485 / 1 x CAN, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), 1 x alarm contact,
GPRS

Via web browser and touch


screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

Via web browser and touch


screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
2 x RS485 / 1 x CAN, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), 1 x alarm contact,
input for ripple control signal,
compatibility of power
management with inverter
types on request
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

1000 m
115 - 230 V / 12 V
3W
-10 to +50 C
IP20
Plastic
LCD status display, graphic
display with touch screen
2 x RS485 / 1 x CAN, 1 x RS485,
1 x Ethernet - RJ45 bush 10/100 MBit, 1 x USB, 2 x S0-In,
1 x potential-free contact
(relay), 1 x alarm contact,
GPRS, input for ripple control
signal, compatibility of power
management with inverter
types on request
Via web browser and touch
screen display
Multi-lingual
Integrated web server
225 mm / 285 mm / 40 mm
0.80 kg
5 years

Interface

Handling
Languages
Data interpretation
Dimensions (L / W / H)
Weight
Warranty

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

75

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Datalogger

...................................................................................................................................................................

76

Accessories
Art. No.
0802174

Model
Solar-Log cable set to SMA, 3 m

0802176

Solar-Log cable set to Danfoss, 3 m

0802190

Solar-Log SensorBox for


200/500/1000/1200/2000

0802191

Solar-Log wind sensor, accessory for


SensorBox

0802192

Solar-Log temperature sensor,


accessory for SensorBox

0802197

Solar-Log cable set to Kaco, 3 m

0802215

Solar-Log RS485 radio package, min.


80 m range

0802216

Solar-Log Powerline package, twopiece

0802217

Solar-Log Powerline package single,


one-piece

0802221

Solar-Log cable set to Fronius, 3 m

0802222

Solar-Log cable set to Sunways, 3 m

0802242

Solar-Log cable set to Kostal, 3 m

0802247

Solar-Log Sensor basic for


200/300/500/1000
Solar-Log 3-phase current meter,
calibrated

0802265

0802266

Solar-Log 3-phase current meter


ISKRA, non-calibrated

0802295

Solar-Log 300 overvoltage


protection set

0802296

Solar-Log 1200/2000 overvoltage


protection set

0802297

Solar-Log meter current


transformer - Solar-Log 300 Meter
Solar-Log meter current
transformer - Solar-Log 1200 Meter

0802298

Description
Accessory RS485 cable

Belongs to Art. No.


0802273, 0802274, 0802275, 0802276, 0802277,
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Accessory RS485 cable
0802273, 0802274, 0802275, 0802276, 0802277,
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Measuring irradiation and module 0802282, 0802283, 0802284, 0802285, 0802286,
temperature
0802287, 0802288, 0802289, 0802290, 0802291,
0802292, 0802293, 0802294
Measuring wind speed
0802282, 0802283, 0802284, 0802285, 0802286,
0802287, 0802288, 0802289, 0802290, 0802291,
0802292, 0802293, 0802294
Measuring ambient temperature
0802282, 0802283, 0802284, 0802285, 0802286,
0802287, 0802288, 0802289, 0802290, 0802291,
0802292, 0802293, 0802294
Accessory RS485 cable
0802273, 0802274, 0802275, 0802276, 0802277,
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Radio connection inverter to Solar- 0802273, 0802274, 0802275, 0802276, 0802277,
Log
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Powerline connection Solar-Log to 0802273, 0802274, 0802275, 0802276, 0802277,
PC
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Powerline connection Solar-Log to 0802273, 0802274, 0802275, 0802276, 0802277,
PC
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Accessory RS485/422 cable
0802273, 0802274, 0802275, 0802276, 0802277,
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Accessory RS485 cable
0802273, 0802274, 0802275, 0802276, 0802277,
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
For 200/500/1000, accessory RS485 0802273, 0802274, 0802275, 0802276, 0802277,
cable
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Measuring irradiation and module 0802273, 0802274, 0802275, 0802276, 0802277,
temperature
0802278, 0802279, 0802280, 0802281
Digital current meter RS485, S0
0802273, 0802274, 0802275, 0802276, 0802277,
impulse
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
Digital current meter, S0 impulse,
0802273, 0802274, 0802275, 0802276, 0802277,
analogue display
0802278, 0802279, 0802280, 0802281, 0802282,
0802283, 0802284, 0802285, 0802286, 0802287,
0802288, 0802289, 0802290, 0802291, 0802292,
0802293, 0802294
0802273, 0802274, 0802275, 0802276, 0802277,
Solar-Log device protection
0802278, 0802279, 0802280, 0802281
RS485/422 interface, including
extended cover & overvoltage
protection
0802282, 0802283, 0802284, 0802285, 0802286,
Solar-Log device protection
0802287, 0802288, 0802289, 0802290, 0802291,
RS485/422 interface, including
0802292, 0802293, 0802294
extended cover & overvoltage
protection
Monitoring of up to two 3-phase
0802281
lines
Monitoring of up to two 3-phase
0802290
lines

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

77

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Datalogger

...................................................................................................................................................................

Elios4you: PV monitoring and own consumption


control with mobile smart app
Continuously monitors yield and consumption

Elios4you continuously monitors generation, feed-in


and consumption in all three current phases. With
that information, Elios4you determines the available
energy for own photovoltaic consumption.
78

Renders surplus solar energy usable

Elios4you renders surplus, self-generated solar energy


usable for you. Intelligent control can determine as of
which surplus level electrical consumers are automatically switched on.

manufacturers of inverters or system monitoring and


control.

Installation without interference with existing installation

Elios4you is swiftly and easily installed and just as easily


set up without any interference with the existing
installation.

User-friendly app with clearly arranged diagrams


n
n

To be used in any existing PV system with up


to 50 kW
Elios4you may be used in any existing photovoltaic
system with up to 50 kW feed-in rate, independent of

Convenient and simple by means of intelligent monitoring


and control via tablet computer or smart phone, at home or
on the road with the Elios4you smart app.

by

n
n
n

For power generation


Power consumption
Feed-in power
Mains power consumption
Alarm in case of failing power generation

Elios4you continuously monitors power generation, feed-in


and consumption in all three power phases.

...................................................................................................................................................................
Datalogger

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802304

Model
General features

Elios4you WIFI logger up to 15 kW DIN rail installation


6 LEDs for the display of operating functions, system
parameter conguration with iOS or android app for tablet
computer/smart phone
IEEE 802.11b, access point (AP), station (STA)
Power supply single phase 230 Vac, 1.8 W, voltage
measurement 400 V 20 % (single-phase + neutral conductor)

WLAN standard
Power supply
Data storage
Max. length of current sensor
lines
Max. length analogue output
lines *
Stand-by power consumption
Current measuring accuracy
Connections
WLAN antenna
Dimensions
Norms

0802305

Elios4you WIFI logger up to 50 kW DIN rail installation


6 LEDs for the display of operating functions, system
parameter conguration with iOS or android app for tablet
computer/smart phone
IEEE 802.11b, access point (AP), station (STA)
Power supply single phase 230 Vac, 1.8 W, Y-connection for
voltage measurement 400 V 20 % (three-phase + neutral
conductor)
Update every 5 seconds; 15-minute mean values for up to 2 Update every 5 seconds; 15-minute mean values for up to 2
months, via Elios4you smart app unlimited on mobile terminal months, via Elios4you smart app unlimited on mobile terminal
device
device
20 m shielded
20 m shielded
20 m shielded

20 m shielded

2W
Accuracy class 2 (max. 2 % deviation from the actual value of
100 % 5 % of the nominal current; max. 2.5 % deviation at
less than 5 % of the nominal current)
Screw-type terminals for AC power supply and voltage
measurement, for current transformer, for alarm signal input
and for analogue output
Indoor omnidirectional antenna on an RP-SMA screw
connection
Housing with DIN rail, width: 6 modules, 105 x 110 mm
ETSI EN 301 489-1 v1.8.1:2008, ETSI EN 301 489-17 v2.1.1:2009,
ETSI EN 300 328 v1.7.1:2006, EN 61010:2011, EN 61326-1:2007

2W
Accuracy class 2 (max. 2 % deviation from the actual value of
100 % 5 % of the nominal current; max. 2.5 % deviation at
less than 5 % of the nominal current)
Screw-type terminals for AC power supply and voltage
measurement, for current transformer, for alarm signal input
and for analogue output
Indoor omnidirectional antenna on an RP-SMA screw
connection
Housing with DIN rail, width: 6 modules, 105 x 110 mm
ETSI EN 301 489-1 v1.8.1:2008, ETSI EN 301 489-17 v2.1.1:2009,
ETSI EN 300 328 v1.7.1:2006, EN 61010:2011, EN 61326-1:2007

* - Elios4you + Power Reducer

by
TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

79

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Sensors

...................................................................................................................................................................

Spektron irradiation sensors

80

The Spektron 210 and 320 are silicon sensors used for
measuring the solar irradiation. The Spektron 210 provides a voltage proportionally to the intensity of the
solar irradiation. The Spektron 320 has an integrated
amplier. Therefore the sensor signal is amplied and
output as a norm signal. The output signal ranges from
0 to 10 V, 0 to 3.125 V, 0 to 150 mV, and 4 to 20 mA at 0
to 1500 W/m.

Range of application
n

Output and operational check of thermal and photovoltaic solar plants


Controlling of shading equipment on buildings

Spektron 210: The 2-core extension cable is UV-resistant. All


Spektron devices are calibrated beneath a sun light simulator against a reference sensor, which has been calibrated by
the Fraunhofer ISE.

n
n

Instruction and training


Sensor for control systems

Ease of use

The Spektron can be connected directly to a voltmeter


or a datalogger. The voltage measured by the Spektron
210 can be converted into the unit of irradiation
(W/m), using the calibration value imprinted on the
sensor.

Robust casing

The Spektron can be used irrespective of the weather


conditions and under any angle of inclination.

The Spektron 320 can output up to four different norm


signals, due to its integrated circuit board. This board has
to be powered with 5 to 30 V DC or 12 to 30 V DC.

...................................................................................................................................................................
Sensors

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802183

0802259

Model
Measuring range
Sensor type
Sensor accuracy
Outlet
Calibration
Design of the sensor
Supply voltage

Spektron 210
0 - 1500 W/m
Monocrystalline cell (13 mm / 33 mm)
5 % annual mean
Approx. 75 mV at 1000 W/m
Sun Simulator Solar Constant 1200 with reference sensor
calibrated by the ISE
Measuring cell laminated in novaon and EH foil
-

Power consumption
Casing

Z-proled aluminium plate, connection encapsulated

Protection mode
Connection

IP65
Cable 3 m, 2 x 1.0 mm

Spektron 320
0 - 1500 W/m
Monocrystalline cell (33 mm / 40 mm)
5 % annual mean
4 - 20 mA or 0 - 10 V or 0 - 3.125 V or 0 - 150 mV
Sun Simulator Solar Constant 1200 with reference sensor
calibrated by the ISE
Measuring cell enclosed in glass
5 - 30 V DC (at output signal ranges 0 - 3.125 V, 0 - 150 mV, 4 20 mA) or 12 - 30 V DC (at output signal ranges 0 - 10 V, 0 3.125 V, 0 - 150 mV, 4 - 20 mA)
Approx. 30 mW
Polycarbonate, UV-resistant, with PG screw joint and pressure
differential valve
IP65
Connection terminals, 1.5 mm

Mounting
Dimensions (L / W / H)
Weight
Warranty
Norms

6 mm drill hole to be xed with screws


118 mm / 50 mm / 44 mm
250 g (incl. cable)
2 years
CE mark

Mounting with drill hole to be xed with a screw


150 mm / 80 mm / 60 mm
300 g
2 years
CE mark

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

81

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Sensors

...................................................................................................................................................................

TRITEC temperature sensors


TRITEC surface temperature sensor Pt1000

The surface temperature sensor Pt1000 is an adhesive


foil sensor. It was designed for measurements on surfaces and is primarily used for temperature measurements of solar modules.
82

by 0.43 %/K with increasing temperature. By monitoring the temperature at the solar cells, conclusions can
be drawn about the behaviour of the output curve.

TRITEC outside temperature sensor Pt1000

By installing the surface temperature sensor at the


back of a solar module, the module temperature can
be measured. The temperature of solar modules is
crucial for their output, because the output decreases

The outside temperature sensor Pt1000 is integrated in


a weather-proof macrolone housing. Its compact
design makes the sensor extremely exible: it can be
installed anywhere. The UV-resistant plastic housing is
equipped with a two-core connection cable.

TRITEC surface temperature sensor Pt1000

TRITEC outside temperature sensor Pt1000

...................................................................................................................................................................
Sensors

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802118

0802258

Model
Measuring principle
Measuring range
Protection mode
Connection
Dimensions (W / H / D)
Casing

TRITEC surface temperature sensor Pt1000


Platinum resistance wire
-20 to +150 C
IP66
Cable, 3 m, two-conductor connection
50 mm / 50 mm / 8 mm
Injection moulded plastic with aluminium plate, incl. adhesive
tape
120 g
2 years

TRITEC outside temperature sensor Pt1000


Platinum resistance wire
-20 to +150 C
IP56
Cable, 3 m, two-conductor connection
52 mm / 50 mm / 32 mm
Macrolone housing

Weight
Warranty

120 g
2 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

83

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Large-scale Display

...................................................................................................................................................................

Solarfox displays
Making clean energy visible
Individual display

84

Solarfox displays allow the individual and appealing


display of solar data. Using the visually attractive displays indoors and outdoors, all data of a solar system
can be displayed almost in real-time. Combined with
individual features, such as company logos or weather
details, not only system data are communicated, but
the entire displayed content can be customised.

Simple handling

The displays designed for continuous operation (24/7)


can be set up as easily as they are operated. The setup
takes less than 10 minutes, following a user-friendly
setup menu. The devices are operated via the Internet,
and the entire display content can be edited using a
web browser application. In addition to continuous
operation, the devices can be used with a time switch
control activating them on certain days and time.

the appropriate device for any application. Present the


solar data to your guests in your own home, show your
customers the yield of your system directly in the reception area of your company or show the CO2 savings at
the entrance of a public building. The various Solarfox
displays offer a solution for every application. Data
communication between display and datalogger is
provided via the Internet. The display can thus be
very exibly positioned.

Advantages in brief
n

n
n

Flexible application

Be it on private land or company grounds, large or


small displays, indoors or outdoors Solarfox provides

Solarfox SF-200 and SF-300 indoor display Individual and


appealing display of the various parameters and information.

Daily, monthly, annually and overall view of the


energy yield
Possibility of inserting marketing material for system
operators and installers
Visualisation of several PV systems possible with one
display system
Online access to the content of the display
Numerous modules, such as weather forecast, CO2
savings, news, RSS feeds, news ticker, etc.
Compatible with nearly all standard dataloggers

Solarfox SF-400 outdoor display The outdoor displays of


Solarfox are visually attractive and optimally protected.

...................................................................................................................................................................
Large-scale Display

CONTROL AND MEASURING INSTRUMENTS

...................................................................................................................................................................

Art. No.

0802223

0802224

0802225

0802226

Model
Display size
Resolution
Display technology
Application
Casing
Handling
Languages

Dimensions (L / W / H)
Weight
Warranty **

Solarfox SF-200 24"


61 cm (24 inch)
1920 x 1080 pixels
LCD
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 25 W
<6W
170
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
585 mm / 360 mm / 80 mm
12.0 kg
2 years

Solarfox SF-200 32"


81 cm (32 inch)
1366 x 768 pixels
LCD
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 83 W
<8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
100 mm / 800 mm / 490 mm
19.0 kg
2 years

Solarfox SF-200 37"


94 cm (37 inch)
1920 x 1080 pixels
LCD
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 130 W
<8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
120 mm / 930 mm / 570 mm
28.0 kg
2 years

Solarfox SF-200 42"


107 cm (42 inch)
1920 x 1080 pixels
LCD
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 185 W
<8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
110 mm / 1000 mm / 590 mm
29.0 kg
2 years

Art. No.

0802227

0802268

0802269

0802270

Model
Display size
Resolution
Display technology
Application
Casing
Handling
Languages

Solarfox SF-200 47"


119 cm (47 inch)
1920 x 1080 pixels
LCD
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 240 W
<8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
120 mm / 1120 mm / 660 mm
35.0 kg
2 years

Solarfox SF-300 32"


81 cm (32 inch)
1920 x 1080 pixels
LED
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 47 W
8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
764 mm / 484 mm / 35 mm
12.0 kg
2 years

Solarfox SF-300 42"


107 cm (42 inch)
1920 x 1080 pixels
LED
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 109 W
8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
990 mm / 590 mm / 40 mm
15.0 kg
2 years

Solarfox SF-300 47"


119 cm (47 inch)
1920 x 1080 pixels
LED
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 114 W
8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
1100 mm / 650 mm / 40 mm
19.0 kg
2 years

Data visualisation PV system

Additional visualisation
options
Rel. ambient temperature
Protection mode
Power consumption *
Stand-by power consumption
Max. angle of view
Data communication
Other features
Mounting

Data visualisation PV system

Additional visualisation
options
Rel. ambient temperature
Protection mode
Power consumption *
Stand-by power consumption
Max. angle of view
Data communication
Other features
Mounting
Dimensions (L / W / H)
Weight
Warranty **

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

85

...................................................................................................................................................................
CONTROL AND MEASURING INSTRUMENTS

Large-scale Display

...................................................................................................................................................................

86

Art. No.

0802271

0802229

0802230

0802232

Model
Display size
Resolution
Display technology
Application
Casing
Handling
Languages

Solarfox SF-300 55"


140 cm (55 inch)
1920 x 1080 pixels
LED
Indoors
Plastic, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
0 to +50 C
IP0
< 145 W
8W
178
LAN, optional: WLAN, UMTS
Continuous operation or time
switch for individual days and
time
Wall-mounted, ceiling
installation or stand
1282 mm / 825 mm / 38 mm
25.0 kg
2 years

Solarfox SF-400 32"


81 cm (32 inch)
1366 x 768 pixels
LCD
Outdoors
Steel, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
-30 to +45 C
IP65
< 155 W
6 W (without ventilation)
178
LAN
Continuous operation or time
switch for individual days and
time
Wall-mounted model

Solarfox SF-400 42"


107 cm (42 inch)
1920 x 1080 pixels
LCD
Outdoors
Steel, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds, power consumption
-30 to +45 C
IP65
< 250 W
6 W (without ventilation)
178
LAN
Continuous operation or time
switch for individual days and
time
Wall-mounted model

Solarfox SF-400 55"


132 cm (55 inch)
1920 x 1080 pixels
LCD
Outdoors
Steel, black
Via web browser
English / French / German /
Spanish / Italian / Dutch
Current output, daily,
monthly, annual, overall
energy, CO2 savings,
remuneration
Marketing inserts, company
logos, weather forecast, news,
RSS feeds
-30 to +45 C
IP65
< 250 W
6 W (without ventilation)
178
LAN
Continuous operation or time
switch for individual days and
time
Wall-mounted model

232 mm / 895 mm / 630 mm


54.0 kg
2 years

232 mm / 1127 mm / 761 mm 232 mm / 1351 mm / 936 mm


73.0 kg
113.0 kg
2 years
2 years

Data visualisation PV system

Additional visualisation
options
Rel. ambient temperature
Protection mode
Power consumption *
Stand-by power consumption
Max. angle of view
Data communication
Other features
Mounting
Dimensions (L / W / H)
Weight
Warranty **

* - Depending of the ambient temperature, values can vary


** - Warranty for screen: 3 years

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

87

Mounting Systems
Components
Our mounting systems exclusively comprise high-quality
components of stainless steel and aluminium. Tests on
components and proles demonstrate excellent stability
with maximum snow and wind loads.

TRITEC

89

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

TRISTAND mounting system


For pitched roofs, at roofs and fronts
TRISTAND The mounting system

90

The development of the new mounting system


TRISTAND is based on well-founded know-how and
years of practical experience. The knowledge gained
from the implementation of numerous solar systems
resulted in a mounting system that is ideally suited for
all applications from small stand-alone systems to
large grid-connected systems, on pitched and at roofs
as well as fronts.

Insertion prole TS The aluminium prole

The insertion prole TS of the TRISTAND mounting


system allows the easy, quick and thus efcient installation of all popular framed solar modules. After the
insertion of the modules into the aluminium prole,
the modules are held in place by their own weight and
friction. The photovoltaic modules do not need to be
screwed in.

Universal proles UP / UP-L / UP-S The base


proles
The universal proles UP, UPL and UPS are the basic
proles of the TRISTAND mounting system. The universal prole UP is used for standard systems. For appli-

Insertion of modules into the cross bracing of proles the


stable and installation-friendly version for pitched roofs.

cations with low static stresses the universal prole


UPL is used, however for great static stresses UPS.
The revolutionary design of the universal proles
allows for two types of installation: the easy to install
insertion system with cross bracing and the insertion
prole TS or the cost-effective clip system with middle
and end clips. The choice is yours.

SafeClick SC The secure connector

SafeClicks connect the universal proles of the


TRISTAND mounting system securely and easily with
its insertion proles. The practical design of the SafeClick allows easy installation by simply clicking in the
insertion proles. Drilling is not necessary.

Middle rail TS-M The optimal reinforcement

In the case of vertical module insertion and acceptance


of pressures of more than 2400 N/m, some module
manufacturers specify the use of a middle support.
The TRISTAND middle rail TS-M is specically designed
for the mounting system and the ideal support for all
popular modules.

The upright installation represents the more exible and


installation-friendly version for at roofs, which can compensate for any unevenness.

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502622

1502199

1502694

1502200

1502800

Model

TRISTAND insertion
prole TS-31, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
31 mm
6000 mm / 54 mm /
47 mm
1.195 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-34, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
34 mm
6000 mm / 54 mm /
50 mm
1.107 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-35, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
35 mm
3000 mm / 54 mm /
51 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-35, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
35 mm
6000 mm / 54 mm /
51 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-38, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
38 mm
3000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502798

1502695

1502201

1502696

1502202

Model

TRISTAND insertion
prole TS-38, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
38 mm
6000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
40 mm
3000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
40 mm
6000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-42, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
42 mm
3000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-42, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
42 mm
6000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502697

1502661

1502699

1502203

1502700

Model

TRISTAND insertion
prole TS-45, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
45 mm
3000 mm / 54 mm /
61 mm
1.196 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-45, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
45 mm
6000 mm / 54 mm /
61 mm
1.196 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
46 mm
3000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
46 mm
6000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-50, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
50 mm
3000 mm / 54 mm /
66 mm
1.236 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502204

1502707

1502212

1502708

1502653

Model

TRISTAND insertion
prole TS-50, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
50 mm
6000 mm / 54 mm /
66 mm
1.236 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
3000 mm / 40 mm /
41 mm
1.344 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
6000 mm / 40 mm /
41 mm
1.344 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
3000 mm / 40 mm /
41 mm
0.976 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
6000 mm / 40 mm /
41 mm
0.976 kg
IEC 61215 ed. 2 (10.16),
TV

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

91

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

Art. No.

1502824

1502711

1502213

1502715

1502680

Model

TRISTAND universal
prole UP-L, 6.200 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
6200 mm / 40 mm /
41 mm
0.976 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-S, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
3000 mm / 70 mm /
41 mm
1.585 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-S, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
6000 mm / 70 mm /
41 mm
1.585 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-TS, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
3000 mm / 54 mm /
41 mm
1.216 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-TS, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
6000 mm / 54 mm /
41 mm
1.216 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502714

1502211

1502623

1502205

1502702

Model

TRISTAND middle rail


TS-M, 3.000 m, blank
aluminium
Pitched roof, at roof
and building exterior
Any
3000 mm / 85 mm /
17 mm
0.775 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND middle rail


TS-M, 6.000 m, blank
aluminium
Pitched roof, at roof
and building exterior
Any
6000 mm / 85 mm /
17 mm
0.775 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-31, 6.000 m,
black
Pitched roof, at roof
and building exterior
31 mm
6000 mm / 54 mm /
47 mm
1.195 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-34, 6.000 m,
black
Pitched roof, at roof
and building exterior
34 mm
6000 mm / 54 mm /
50 mm
1.107 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-35, 3.000 m,
black
Pitched roof, at roof
and building exterior
35 mm
3000 mm / 54 mm /
51 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502206

1502801

1502799

1502703

1502207

Model

TRISTAND insertion
prole TS-35, 6.000 m,
black
Pitched roof, at roof
and building exterior
35 mm
6000 mm / 54 mm /
51 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-38, 3.000 m,
black
Pitched roof, at roof
and building exterior
38 mm
3000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-38, 6.000 m,
black
Pitched roof, at roof
and building exterior
38 mm
6000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 3.000 m,
black
Pitched roof, at roof
and building exterior
40 mm
3000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 6.000 m,
black
Pitched roof, at roof
and building exterior
40 mm
6000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502704

1502208

1502705

1502209

1502706

Model

TRISTAND insertion
prole TS-42, 3.000 m,
black
Pitched roof, at roof
and building exterior
42 mm
3000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-42, 6.000 m,
black
Pitched roof, at roof
and building exterior
42 mm
6000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 3.000 m,
black
Pitched roof, at roof
and building exterior
46 mm
3000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 6.000 m,
black
Pitched roof, at roof
and building exterior
46 mm
6000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-50, 3.000 m,
black
Pitched roof, at roof
and building exterior
50 mm
3000 mm / 54 mm /
66 mm
1.236 kg
IEC 61215 ed. 2 (10.16),
TV

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

92

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502210

1502712

1502415

1502713

1502654

Model

TRISTAND insertion
prole TS-50, 6.000 m,
black
Pitched roof, at roof
and building exterior
50 mm
6000 mm / 54 mm /
66 mm
1.236 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP, 3.000 m,
black
Pitched roof, at roof
and building exterior
Any
3000 mm / 40 mm /
41 mm
1.344 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP, 6.000 m,
black
Pitched roof, at roof
and building exterior
Any
6000 mm / 40 mm /
41 mm
1.344 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 3.000 m,
black
Pitched roof, at roof
and building exterior
Any
3000 mm / 40 mm /
41 mm
0.976 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 6.000 m,
black
Pitched roof, at roof
and building exterior
Any
6000 mm / 40 mm /
41 mm
0.976 kg
IEC 61215 ed. 2 (10.16),
TV

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms

Art. No.

1502416

1502739

1502740

1502414

Model

TRISTAND universal prole


UP-S, 6.000 m, black
Pitched roof, at roof and
building exterior
Any
6000 mm / 70 mm / 41 mm
1.585 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND universal prole


UP-TS, 6.000 m, black
Pitched roof, at roof and
building exterior
Any
6000 mm / 54 mm / 41 mm
1.216 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND middle rail TS-M,


3.000 m, black
Pitched roof, at roof and
building exterior
Any
3000 mm / 85 mm / 17 mm
0.775 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND middle rail TS-M,


6.000 m, black
Pitched roof, at roof and
building exterior
Any
6000 mm / 85 mm / 17 mm
0.775 kg
IEC 61215 ed. 2 (10.16), TV

Application
Frame thickness
Dimensions (L / W / H)
Weight *
Norms
* - Per meter
Accessories
Art. No.

Model

1502214

1502307

1502215

1502436

1502216

TRISTAND insertion
prole connector TS-C

Application
Dimensions (L / W / H)
Weight

TRISTAND end bracket TRISTAND end bracket TRISTAND SafeClick SC TRISTAND special
TS-E, blank aluminium TS-E, black
SafeClick, with 7 mm
drill hole
Pitched and at roof
Pitched and at roof
Pitched and at roof
Pitched roof
32 mm / 29 mm / 33 mm 32 mm / 29 mm / 33 mm 13 mm / 45 mm / 70 mm 13 mm / 45 mm / 70 mm
0.010 kg
0.010 kg
0.050 kg
0.050 kg

Pitched and at roof


95 mm / 64 mm / 17 mm
0.080 kg

Art. No.

1502217

1502218

1502222

1502223

Model

TRISTAND universal
prole connector UP-C
Pitched and at roof
120 mm / 51 mm /
41 mm
0.130 kg

TRISTAND slide nut M8 TRISTAND slide nut


M10
Pitched and at roof
Pitched and at roof
32 mm / 21 mm / 9 mm 32 mm / 21 mm / 9 mm

TRISTAND FlexFix (20 70)


Flat roof
65 mm / 40 mm / 35 mm

0.010 kg

0.150 kg

TRISTAND Z adapter
UP-Z
Pitched and at roof
102 mm / 30 mm /
34 mm
0.200 kg

Application
Dimensions (L / W / H)
Weight

1502219

0.010 kg

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

93

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

Art. No.

1502224

Model

1502410

1502226

1502227

TRISTAND middle clip


(41 - 50 mm), blank
aluminium
Pitched and at roof
70 mm / 35 mm / 27 mm
0.100 kg

TRISTAND middle clip


(31 - 40 mm), black

Application
Dimensions (L / W / H)
Weight

TRISTAND spacer UP-D, TRISTAND spacer UP-D, TRISTAND middle clip


3 mm
6 mm
(31 - 40 mm), blank
aluminium
Pitched and at roof
Pitched and at roof
Pitched and at roof
56 mm / 35 mm / 3 mm 56 mm / 35 mm / 6 mm 70 mm / 35 mm / 27 mm
0.050 kg
0.100 kg
0.100 kg

Pitched and at roof


70 mm / 35 mm / 27 mm
0.100 kg

Art. No.

1502228

1502229

1502230

1502233

Model

TRISTAND middle clip


(41 - 50 mm), black

TRISTAND end clip


34 mm, blank
aluminium
Pitched and at roof
50 mm / 34 mm / 27 mm
0.040 kg

TRISTAND end clip


35 mm, blank
aluminium
Pitched and at roof
50 mm / 35 mm / 27 mm
0.040 kg

TRISTAND end clip


40 mm, blank
aluminium
Pitched and at roof
50 mm / 40 mm / 27 mm
0.040 kg

1502632

1502225

94

Application
Dimensions (L / W / H)
Weight

TRISTAND end clip


31 mm, blank
aluminium
Pitched and at roof
Pitched and at roof
70 mm / 35 mm / 27 mm 50 mm / 31 mm / 27 mm
0.100 kg
0.040 kg

Art. No.

1502234

1502665

1502235

1502236

Model
Application
Dimensions (L / W / H)
Weight

TRISTAND end clip 42 mm,


blank aluminium
Pitched and at roof
50 mm / 42 mm / 27 mm
0.040 kg

TRISTAND end clip 45 mm,


blank aluminium
Pitched and at roof
50 mm / 45 mm / 27 mm
0.040 kg

TRISTAND end clip 46 mm,


blank aluminium
Pitched and at roof
50 mm / 46 mm / 27 mm
0.040 kg

TRISTAND end clip 50 mm,


blank aluminium
Pitched and at roof
50 mm / 50 mm / 27 mm
0.040 kg

Art. No.

1502633

1502237

1502238

1502241

Model
Application
Dimensions (L / W / H)
Weight

TRISTAND end clip 31 mm,


black
Pitched and at roof
50 mm / 31 mm / 27 mm
0.040 kg

TRISTAND end clip 34 mm,


black
Pitched and at roof
50 mm / 34 mm / 27 mm
0.040 kg

TRISTAND end clip 35 mm,


black
Pitched and at roof
50 mm / 35 mm / 27 mm
0.040 kg

TRISTAND end clip 40 mm,


black
Pitched and at roof
50 mm / 40 mm / 27 mm
0.040 kg

Art. No.

1502242

1502243

1502244

1502777

Model

TRISTAND end clip 42 mm,


black
Pitched and at roof
50 mm / 42 mm / 27 mm
0.040 kg

TRISTAND end clip 46 mm,


black
Pitched and at roof
50 mm / 46 mm / 27 mm
0.040 kg

TRISTAND end clip 50 mm,


black
Pitched and at roof
50 mm / 50 mm / 27 mm
0.040 kg

TRISTAND bending tool

Application
Dimensions (L / W / H)
Weight

Pitched and at roof


292 mm / 18 mm / 6 mm
0.231 kg

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1302257

1302258

1502245

1502246

Model

TRISTAND grounding clamp


for insertion prole TS
Pitched and at roof
16 mm / 10 mm / 13 mm
0.002 kg

TRISTAND grounding clamp


for connector TSC
Pitched and at roof
21 mm / 10 mm / 13 mm
0.002 kg

TRISTAND cross cable clip


block UP-K
Pitched and at roof
22 mm / 22 mm / 16 mm
0.002 kg

TRISTAND edge clip TSEC

Application
Dimensions (L / W / H)
Weight

Pitched and at roof


18 mm / 15 mm / 11 mm
0.001 kg

TRISTAND has successfully passed the TV tests. Patent applications have been led for SafeClick and FlexFix.
Other TRISTAND prole types upon request.
For the insertion system, please comply with the module manufacturer's instructions.

95

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

TRISTAND Aero
Aerodynamically optimised mounting system
The mounting system for large at roofs

TRISTAND Aero is the logically consistent development of the proven PV mounting system TRISTAND.
The new mounting system is based on TRISTAND components, but is designed especially for efcient use on
large at roofs.

96

Smaller loads, less costs

Due to its aerodynamically optimised shape, the


mounting system TRISTAND Aero offers signicant
advantages in terms of load and costs. The new PV
mounting system puts considerably less weight on
roofs than conventional module supports. Compared
to the conventional at roof supports, TRISTAND Aero
needs at least 50 % less ballast for the installation.

pressure loads on the underside of the modules. The


centrepiece is the newly developed TS-F bracket. It is
used to attach the module to the bottom proles and
the vertical proles providing support on the back. The
bracket makes the diagonal prole superuous and
thus saves material costs. Instead, the module is
screwed directly onto the mounting holes.

Less shading, more output

The back of the elevation is clad with a metal sheet that


both reduces the dynamic pressure and prevents wind

Since the PV modules are supported at an angle of 20


degrees, the shading distances reduce and the output
per square metre increases. Installing the TRISTAND
Aero system keeps the roof covering intact. The system
is designed for modules with a width of 790 810 mm
and 990 1010 mm. Modules with these dimensions
are state-of-the-art. The required back sheets are tailored to these dimensions. As a result, customers are
spared expensive customised components and benet
from an efcient product.

The TRISTAND Aero mounting system load and cost-optimised.

The TS-F bracket is the centrepiece of the TRISTAND Aero


mounting system.

The centrepiece the TS-F bracket

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502730

1502732

1502733

Model

TRISTAND Aero TS-F


bracket (6 per module)

TRISTAND Aero
threaded plate A2 (4
per module)
Flat roof
Any
Module width 790 810 mm and 990 1010 mm
40 mm / 14 mm / 5 mm

TRISTAND Aero drilling TRISTAND Aero wind


screw 6.3 x 25 A2
deector, 790 - 810 mm

Dimensions (L / W / H)

TRISTAND Aero
hexagon set screw M6 x
16 A2
Flat roof
Flat roof
Any
Any
Module width 790 Module width 790 810 mm and 990 810 mm and 990 1010 mm
1010 mm
89 mm / 40 mm / 39 mm 22 mm / 8 mm / 8 mm

Weight
Norms

0.024 kg
Wind channel test

0.005 kg
Wind channel test

0.010 kg
Wind channel test

0.004 kg
Wind channel test

2500 mm / 345 mm /
83 mm
2.800 kg
Wind channel test

Art. No.

1502736

1502744

1502254

1502737

1502738

Model

TRISTAND Aero wind


deector, 990 1010 mm
Flat roof
Any
Module width 990 1010 mm

TRISTAND hammerTRISTAND self-locking


head screw M10 x 20 A2 nut with serrated
bearing surface M10 A2
Flat roof
Flat roof
Any
Any
Module width 790 Module width 790 810 mm and 990 810 mm and 990 1010 mm
1010 mm
20 mm / 10 mm / 10 mm 20 mm / 20 mm / 10 mm

TRISTAND Aero
universal prole UP-L,
0.272 m
Flat roof
Any
Module width 790 810 mm

TRISTAND Aero
universal prole UP-L,
0.341 m
Flat roof
Any
Module width 990 1010 mm

Application
Frame thickness
Module brand

Application
Frame thickness
Module brand
Dimensions (L / W / H)

1502731

Weight
Norms

2500 mm / 412 mm /
83 mm
3.260 kg
Wind channel test

Art. No.

1502742

1502743

Model

TRISTAND Aero universal


prole UP-L, 1.140 m

TRISTAND Aero universal


prole UP-L, 1.340 m

Application
Frame thickness
Module brand

Flat roof
Any
Module width 790 - 810 mm

Dimensions (L / W / H)
Weight
Norms

1502735

Flat roof
Any
Module width 790 810 mm and 990 1010 mm
31 mm / 8 mm / 8 mm

272 mm / 40 mm /
41 mm
0.021 kg
0.011 kg
0.265 kg
IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), Wind channel test
TV
TV
1502708

Flat roof
Any
Module width 790 810 mm

341 mm / 40 mm /
41 mm
0.333 kg
Wind channel test
1502653

1140 mm / 40 mm / 41 mm
1.110 kg
Wind channel test

TRISTAND universal prole


UP-L, 3.000 m, blank
aluminium
Flat roof
Flat roof
Any
Any
Module width 990 - 1010 mm Module width 790 - 810 mm
and 990 - 1010 mm
1340 mm / 40 mm / 41 mm
3000 mm / 40 mm / 41 mm
1.308 kg
3.000 kg
Wind channel test
IEC 61215 ed. 2 (10.16), TV

TRISTAND universal prole


UP-L, 6.000 m, blank
aluminium
Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
6000 mm / 40 mm / 41 mm
6.000 kg
IEC 61215 ed. 2 (10.16), TV

Art. No.

1502824

1502707

1502711

Model

TRISTAND universal prole


UP-L, 6.200 m, blank
aluminium
Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
6200 mm / 40 mm / 41 mm
6.200 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND universal prole


TRISTAND universal prole
TRISTAND universal prole
UP, 3.000 m, blank aluminium UP, 6.000 m, blank aluminium UP-S, 3.000 m, blank
aluminium
Flat roof
Flat roof
Flat roof
Any
Any
Any
Module width 790 - 810 mm Module width 790 - 810 mm Module width 790 - 810 mm
and 990 - 1010 mm
and 990 - 1010 mm
and 990 - 1010 mm
3000 mm / 40 mm / 41 mm
6000 mm / 40 mm / 41 mm
3000 mm / 70 mm / 41 mm
3.900 kg
7.800 kg
4.800 kg
IEC 61215 ed. 2 (10.16), TV
IEC 61215 ed. 2 (10.16), TV
IEC 61215 ed. 2 (10.16), TV

Application
Frame thickness
Module brand
Dimensions (L / W / H)
Weight
Norms

1502212

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

97

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

Art. No.

1502213

1502217

1502245

1502246

Model

TRISTAND universal prole


UP-S, 6.000 m, blank
aluminium
Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
6000 mm / 70 mm / 41 mm
9.600 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND universal prole


connector UP-C

TRISTAND cross cable clip


block UP-K

TRISTAND edge clip TSEC

Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
120 mm / 51 mm / 41 mm
0.130 kg
IEC 61215 ed. 2 (10.16), TV

Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
22 mm / 22 mm / 16 mm
0.002 kg
IEC 61215 ed. 2 (10.16), TV

Flat roof
Any
Module width 790 - 810 mm
and 990 - 1010 mm
18 mm / 15 mm / 11 mm
0.001 kg
IEC 61215 ed. 2 (10.16), TV

...................................................................................................................................................................

Application
Frame thickness
Module brand
Dimensions (L / W / H)
Weight
Norms

98

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

99

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

TRISTAND East-West for at roofs


Energy for higher own consumption

100

With TRISTAND East-West, TRITEC provides the ideal


solution for PV systems with an east/west orientation.
The advantage of these systems is their more uniform
and longer energy generation during the course of the
day as compared with southern exposure systems.
Own consumption of solar power can thus be signicantly increased, as well as the protability of the PV
system especially in combination with storage systems.

Flexible, simple and quick

degrees. The insertion variant is particularly simple and


quick and provides for an optimum load distribution.

Proven components, maximum security

TRISTAND East-West is a further development of the


TRISTAND mounting system which has been proven in
many years of practice and in TV testing. The components are exclusively manufactured of high-quality aluminium and special stainless V2A steel. TRISTAND
East-West is also suitable for locations with high wind
and snow loads of up to 5400 N/m.

Few components, the plug-in system and the use of


long rails provide for the uncomplicated installation
within the shortest possible time and without damage
to the roong. TRISTAND East-West is particularly
exible: It may be installed both in the insertion system
and the clip system at an angle of inclination of 10 or 20

Aerodynamically optimized

With TRISTAND East-West, any size of systems may be realized optimally adjusted to the specic own consumption.

The OW-h 10 support allows fast and screwless installation


of the triangle supports.

TRISTAND East-West may be used on all at roofs even


if they can only take minor loads. Thanks to its aerodynamically optimized form, the mounting system cannot only save loads but costs as well.

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502821

1502825

1502826

1502808

1502809

Model

TRISTAND OW 10 end
bracket
Flat roof
Any
Module width 600 1050 mm
50 pc.
105 mm / 40 mm / 5 mm

TRISTAND OW 20 end
bracket
Flat roof
Any
Module width 600 1050 mm
50 pc.
102 mm / 40 mm / 5 mm

TRISTAND OW 10
bracket
Flat roof
Any
Module width 600 1050 mm
50 pc.
172 mm / 40 mm / 5 mm

TRISTAND OW 20
bracket
Flat roof
Any
Module width 600 1050 mm
50 pc.
159 mm / 40 mm / 5 mm

Weight *
Norms

TRISTAND ballast sheet


for UP proles
Flat roof
Any
Module width 600 1050 mm
25 pc.
190 mm / 354 mm /
42 mm
0.210 kg
DIN EN 1999-1-1

0.136 kg
DIN EN 1993-1-1

0.136 kg
DIN EN 1993-1-1

0.176 kg
DIN EN 1993-1-1

0.176 kg
DIN EN 1993-1-1

Art. No.

1502810

1502822

1502708

1502653

1502824

Model

Application
Frame thickness
Module brand (examples)
Packaging unit
Dimensions (L / W / H)

TRISTAND OW-h 10
support, horizontal
installation
Flat roof

TRISTAND end clip


insert for longitudinal
clamping
Flat roof

TRISTAND universal
prole UP-L, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
Any
Any
Module width 600 Module width 600 Basic prole for all
1050 mm
1050 mm
TRISTAND insertion
proles
50 pc.
50 pc.
100 pc.
221 mm / 22 mm / 5 mm 40 mm / 21 mm / 5 mm 3000 mm / 40 mm /
41 mm
0.176 kg
0.031 kg
1.000 kg
DIN EN 1993-1-1
DIN EN 1999-1-1
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
Basic prole for all
TRISTAND insertion
proles
100 pc.
6000 mm / 40 mm /
41 mm
1.000 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-L, 6.200 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
Basic prole for all
TRISTAND insertion
proles
100 pc.
6200 mm / 40 mm /
41 mm
1.000 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502711

1502213

1502693

1502622

1502199

Model

TRISTAND universal
prole UP-S, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
Basic prole for all
TRISTAND insertion
proles
100 pc.
3000 mm / 70 mm /
41 mm
1.600 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND universal
prole UP-S, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
Any
Basic prole for all
TRISTAND insertion
proles
100 pc.
6000 mm / 70 mm /
41 mm
1.600 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-31, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
31 mm
SolarWorld

TRISTAND insertion
prole TS-31, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
31 mm
SolarWorld

TRISTAND insertion
prole TS-34, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
34 mm
SolarWorld, Isofoton,
Naps Systems, Solartec

100 pc.
3000 mm / 54 mm /
47 mm
1.100 kg
IEC 61215 ed. 2 (10.16),
TV

100 pc.
6000 mm / 54 mm /
47 mm
1.100 kg
IEC 61215 ed. 2 (10.16),
TV

100 pc.
6000 mm / 54 mm /
50 mm
1.100 kg
IEC 61215 ed. 2 (10.16),
TV

Application
Frame thickness
Module brand (examples)
Packaging unit
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Module brand (examples)
Packaging unit
Dimensions (L / W / H)
Weight *
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

101

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

Art. No.

1502694

1502200

1502695

1502201

1502696

Model

TRISTAND insertion
prole TS-35, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
35 mm
Sanyo, Solarfabrik,
Wrth Solar, Canadian
Solar, DAY4 Energy, GE
Energy, Mitsubishi
Heavy Industries,
Solara, Solarfun Power,
Suntech Power,
Viessmann
100 pc.
3000 mm / 54 mm /
51 mm
1.100 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-35, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
35 mm
Sanyo, Solarfabrik,
Wrth Solar, Canadian
Solar, DAY4 Energy, GE
Energy, Mitsubishi
Heavy Industries,
Solara, Solarfun Power,
Suntech Power,
Viessmann
100 pc.
6000 mm / 54 mm /
51 mm
1.100 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
40 mm
Hareon Solar, JA Solar,
Isofoton, Topsolar,
Bisol, Canadian Solar,
Kaneka, MSK, Siliken

TRISTAND insertion
prole TS-40, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
40 mm
Hareon Solar, JA Solar,
Isofoton, Topsolar,
Bisol, Canadian Solar,
Kaneka, MSK, Siliken

TRISTAND insertion
prole TS-42, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
42 mm
Kaneka, Five Star
Energy, Ibersolar
Energia, MDT
technologies, Scheuten
Solar Technology, Solon

100 pc.
3000 mm / 54 mm /
56 mm
1.200 kg
IEC 61215 ed. 2 (10.16),
TV

100 pc.
6000 mm / 54 mm /
56 mm
1.200 kg
IEC 61215 ed. 2 (10.16),
TV

100 pc.
3000 mm / 54 mm /
58 mm
1.200 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502202

1502697

1502661

1502699

1502203

Model

TRISTAND insertion
prole TS-46, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
46 mm
Kyocera, Sharp,
Sunpower, Chaori,
Kaneka, Mitsubishi
Electric, MSK, Sanyo
Electric, Shanghai
Chaori Solar Energy,
Vaillant
100 pc.
100 pc.
100 pc.
100 pc.
6000 mm / 54 mm /
3000 mm / 54 mm /
6000 mm / 54 mm /
3000 mm / 54 mm /
58 mm
61 mm
61 mm
62 mm
1.200 kg
1.200 kg
1.200 kg
1.200 kg
IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16),
TV
TV
TV
TV

Application
Frame thickness
Module brand (examples)

102

Packaging unit
Dimensions (L / W / H)
Weight *
Norms

Application
Frame thickness
Module brand (examples)

Packaging unit
Dimensions (L / W / H)
Weight *
Norms

TRISTAND insertion
prole TS-42, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
42 mm
Kaneka, Five Star
Energy, Ibersolar
Energia, MDT
technologies, Scheuten
Solar Technology, Solon

TRISTAND insertion
prole TS-45, 3.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
45 mm
Hareon Solar, Jinko

TRISTAND insertion
prole TS-45, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
45 mm
Hareon Solar, Jinko

TRISTAND insertion
prole TS-46, 6.000 m,
blank aluminium
Pitched roof, at roof
and building exterior
46 mm
Kyocera, Sharp,
Sunpower, Chaori,
Kaneka, Mitsubishi
Electric, MSK, Sanyo
Electric, Shanghai
Chaori Solar Energy,
Vaillant
100 pc.
6000 mm / 54 mm /
62 mm
1.200 kg
IEC 61215 ed. 2 (10.16),
TV

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502700

1502204

1502247

1502248

Model

TRISTAND insertion prole


TS-50, 3.000 m, blank
aluminium
Pitched roof, at roof and
building exterior
50 mm
Schott, Yingli, Aleo, BP Solar,
Unisolar, Eging, Advent Solar,
Aleo Solar, Atersa, MDT
technologies, Solara,
Solarfabrik, Solarwatt, Sunlink
PV, Suntech Power, Sunways
Photovoltaic, Vaillant,
Viessmann
100 pc.
3000 mm / 54 mm / 66 mm
1.200 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND insertion prole


TS-50, 6.000 m, blank
aluminium
Pitched roof, at roof and
building exterior
50 mm
Schott, Yingli, Aleo, BP Solar,
Unisolar, Eging, Advent Solar,
Aleo Solar, Atersa, MDT
technologies, Solara,
Solarfabrik, Solarwatt, Sunlink
PV, Suntech Power, Sunways
Photovoltaic, Vaillant,
Viessmann
100 pc.
6000 mm / 54 mm / 66 mm
1.200 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND bracket 90,


without screw

TRISTAND bracket 110,


without screw

Flat roof

Flat roof

Application
Frame thickness
Module brand (examples)

Packaging unit
Dimensions (L / W / H)
Weight *
Norms

Any
Any
Module width 600 - 1050 mm Module width 600 - 1050 mm

20 pc.
92 mm / 40 mm / 52 mm
0.125 kg
DIN EN 1993

20 pc.
107 mm / 40 mm / 48 mm
0.125 kg
DIN EN 1993

* - Prole weight per meter


Accessories
Art. No.

1502215

1502214

1502216

1502217

1302257

TRISTAND universal
prole connector UP-C

TRISTAND grounding
clamp for insertion
prole TS
Pitched and at roof
16 mm / 10 mm / 13 mm

Model

TRISTAND SafeClick SC TRISTAND end bracket TRISTAND insertion


TS-E, blank aluminium prole connector TS-C

Application
Dimensions (L / W / H)
Weight

Pitched and at roof


Pitched and at roof
Pitched and at roof
Pitched and at roof
13 mm / 45 mm / 70 mm 32 mm / 29 mm / 33 mm 95 mm / 64 mm / 17 mm 120 mm / 51 mm /
41 mm
0.050 kg
0.010 kg
0.080 kg
0.130 kg

Art. No.

1302258

1502245

1502246

Model

TRISTAND cross cable


clip block UP-K

TRISTAND edge clip


TSEC

Application
Dimensions (L / W / H)
Weight

TRISTAND grounding
clamp for connector
TSC
Pitched and at roof
21 mm / 10 mm / 13 mm
0.002 kg

TRISTAND middle clip


(31 - 40 mm), blank
aluminium
Pitched and at roof
Pitched and at roof
Pitched and at roof
22 mm / 22 mm / 16 mm 18 mm / 15 mm / 11 mm 70 mm / 35 mm / 27 mm
0.002 kg
0.001 kg
0.100 kg

TRISTAND middle clip


(41 - 50 mm), blank
aluminium
Pitched and at roof
70 mm / 35 mm / 27 mm
0.100 kg

Art. No.

1502632

1502229

1502230

1502233

1502234

Model

TRISTAND end clip


31 mm, blank
aluminium
Pitched and at roof
50 mm / 31 mm / 27 mm
0.040 kg

TRISTAND end clip


34 mm, blank
aluminium
Pitched and at roof
50 mm / 34 mm / 27 mm
0.040 kg

TRISTAND end clip


35 mm, blank
aluminium
Pitched and at roof
50 mm / 35 mm / 27 mm
0.040 kg

TRISTAND end clip


40 mm, blank
aluminium
Pitched and at roof
50 mm / 40 mm / 27 mm
0.040 kg

TRISTAND end clip


42 mm, blank
aluminium
Pitched and at roof
50 mm / 42 mm / 27 mm
0.040 kg

Application
Dimensions (L / W / H)
Weight

1502225

0.002 kg
1502226

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

103

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

Art. No.

1502665

1502235

1502236

1502744

Model

TRISTAND end clip


45 mm, blank
aluminium
Pitched and at roof
50 mm / 45 mm / 27 mm
0.040 kg

TRISTAND end clip


46 mm, blank
aluminium
Pitched and at roof
50 mm / 46 mm / 27 mm
0.040 kg

TRISTAND end clip


50 mm, blank
aluminium
Pitched and at roof
50 mm / 50 mm / 27 mm
0.040 kg

TRISTAND hammerTRISTAND self-locking


head screw M10 x 20 A2 nut with serrated
bearing surface M10 A2
Pitched and at roof
Pitched and at roof
20 mm / 10 mm / 10 mm 20 mm / 20 mm / 10 mm
0.021 kg
0.011 kg

Application
Dimensions (L / W / H)
Weight

1502254

104

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

105

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

TRISTAND mounting accessories


Roof hooks

Hanger bolts

Roof fold clamps

Renosol plates

As standard, roof hooks are available in xed or once adjustable versions and are suited to almost any type of tile.

Using plate fold clamps, the TRISTAND proles can be


attached to the plate fold roof directly.

For the assembly of substructures rst fastenings must


be installed at the appropriate grid spacings. On tiled
roofs, the roof hooks are attached either directly to the
rafter or to distance battens above the rafter. Roof
hooks are available for almost any type of tile and
are secured by means of seating bolts.
106

In the case of plate fold roofs, the clamps are installed


directly at the fold. The clamps consist of two stainless
steel metal sheets, which are bolted together. The roof
fold clamps are available in a round version, especially
for Kalzip roofs. The substructure can be mounted on
the clamps, without disturbing the roof surface.

For the installation on a corrugated roof type, the


existing screws are replaced by hanger bolts. This
secures the corrugated roof, and at the same time
the hanger bolts can be used for the installation of
the substructure. This provides the base for the installation with a minimum of time and effort.

For at roofs, generally Renosol plates are used. The


gravel is removed from the required at roof area, a
protective mat or eece is laid and the Renosol plate is
placed on this. Then the TRISTAND proles UP and
UPS can be riveted directly to the Renosol plate.
Finally, the Renosol plates must be weighed down
again with gravel, in order to meet the static requirements.

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502247

1502248

1502249

1502305

1502306

Model

TRISTAND bracket 90,


without screw
Flat roof and building
exterior

TRISTAND bracket
110, without screw
Flat roof and building
exterior

TRISTAND bracket
120, without screw
Flat roof and building
exterior

TRISTAND bracket
150, without screw
Flat roof and building
exterior

TRISTAND bracket
160, without screw
Flat roof and building
exterior

Art. No.

1502308

1502250

1502251

1502252

1502253

Model

TRISTAND at
connector, for
stiffening
Flat roof and building
exterior

TRISTAND SafeClick
basic element

TRISTAND lens head


screw M8x25 A2

TRISTAND retaining
washer M8x25 A2

TRISTAND round-head
screw M10x30 A2

Pitched roof, at roof


and building exterior

Pitched roof, at roof


and building exterior

Pitched roof, at roof


and building exterior

Pitched roof, at roof


and building exterior

Art. No.

1502278

1502254

1502255

1502256

1502280

Model

TRISTAND round-head
screw M10x50 A2

TRISTAND hammerTRISTAND hexagon


head screw M10x30 A2 bolt M10x25 A2

TRISTAND cable tie


pliers

Application

Pitched roof, at roof


and building exterior

TRISTAND self-locking
nut with serrated
bearing surface M10 A2
Pitched roof, at roof
and building exterior

Pitched roof, at roof


and building exterior

Pitched roof, at roof


and building exterior

Pitched roof, at roof


and building exterior

Art. No.

1502257

1502258

1502259

1502260

1502279

Model

TRISTAND Renosol
plate 800x600x35

TRISTAND washer M8
23x8.4, for Peel rivet

TRISTAND rivet gun

Application

Flat roof

TRISTAND Peel rivet


TRISTAND Peel rivet
incl. washer, M8 73x6.3 without washer, M8
73x6.3
Flat roof
Flat roof

Flat roof

Flat roof

Art. No.

1502261

1502264

1502266

1502267

Model
Application

TRISTAND hanger bolt TRISTAND hanger bolt TRISTAND hanger bolt TRISTAND roof hook
M12x250
M12x300
M12x350
xed
Pitched and at roof
Pitched and at roof
Pitched and at roof
Pitched roof

TRISTAND roof hook


once variable
Pitched roof

Art. No.

1502270

1502271

1502273

1502274

Model

TRISTAND crown tile


roof hook xed

TRISTAND crown tile


TRISTAND slate roof
roof hook once variable hook xed

TRISTAND slate roof


hook once variable

Application

Pitched roof

Pitched roof

Pitched roof

TRISTAND trapezoidal
plate shoe, with
bracket, M10
Pitched roof

Application

Application

1502265

1502272

Pitched roof

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

107

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

108

Art. No.

1502867

1502275

Model
Application

TRISTAND fold clamp


for plate fold roof, M10,
strong
Pitched roof

TRISTAND fold clamp TRISTAND round fold


for plate fold roof, M10, clamp, M10
light
Pitched roof
Pitched roof

Art. No.

1502281

Model

TRISTAND seating bolt 8.0x80 TRISTAND seating bolt


8.0x120
Pitched roof
Pitched roof

Application

1502276

1502282

The hanger bolts are available in different lengths to allow


the perfect alignment with the existing corrugated roof
shape.

1502277

1502421

TRISTAND rectangle
clamp for Rib Roof 465,
M10
Pitched roof

TRISTAND rectangle
clamp for Rib Roof 500,
M10
Pitched roof

1502283

1502284

TRISTAND seating bolt


8.0x160
Pitched roof

TRISTAND seating bolt


8.0x200
Pitched roof

The Renosol plates are used for installations on at roofs


and weighed down with gravel for example.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

109

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

...................................................................................................................................................................

TRIFLAT East-West and TRIFLAT South for at


roofs
Low transport and storage costs

With these two TRIFLAT mounting systems, TRITEC


offers the ideal solution for PV systems at a south or
east-west orientation and with 10 or 15 supports.
Both systems are based on only a few components
which are all stackable and t on Euro pallets ideal
for economical and efcient transportation to the construction site.
110

No-tool module installation

Swift and uncomplicated installation is a special feature of TRIFLAT East-West and TRIFLAT South. The
bottom rails are telescopically pushed into each other
and xed in place by a special bending tool so that they
can be adjusted to the respective module size. The
installation does not require any roof penetration.
Both mounting systems are suitable for all framed
modules in transverse installation. These are clamped
on their long side by a simple click system.

With an east-west roof, up to double the area for power


generation will be available. The PV system ensures high
yields especially during the peak-consumption hours of
households, i.e. mornings and evenings.

Aerodynamically optimized

TRIFLAT East-West and TRIFLAT South were tested in


the wind tunnel. Accordingly, these systems can be
used on at roofs even if such roofs can accept only
minor loads. Any ballasting which is generally necessary only in the area of edges will be attached underneath the module and is accordingly not visible.

Applications at a glance
n

TRIFLAT East-West for PV systems with east-west


orientation
TRIFLAT South for PV systems with a southern orientation
Both systems are suitable for at roofs of up to 5
inclination
Suitable for at roofs, such as membrane roofs,
gravel, concrete and substrate roofs as well as for
green roofs

Normally, PV systems oriented towards the south provide


the best output (kWh/kWp). The atter the covering of at
roofs, the lower the amount of shading and the more modules can be used.

...................................................................................................................................................................
On-the-Roof System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502827

1502828

1502829

1502830

1502831

Model

TRIFLAT clip for


ballasting
Flat roof
Any
Module width 790 1050 mm
100 pc.
20 mm / 150 mm /
37 mm
0.022 kg
DIN EN 1999-1-1

TRIFLAT clip, bottom


Flat roof
Any
Module width 790 1050 mm
200 pc.
25 mm / 46 mm / 35 mm

TRIFLAT holder, top,


10
Flat roof
Any
Module width 790 1050 mm
100 pc.
40 mm / 78 mm / 64 mm

TRIFLAT holder,
bottom, 10
Flat roof
Any
Module width 790 1050 mm
100 pc.
41 mm / 88 mm / 42 mm

Weight
Norms

TRIFLAT bottom
prole, L = 1145 mm
Flat roof
Any
Module width 790 1050 mm
1 pc.
1145 mm / 100 mm /
36 mm
0.804 kg
DIN EN 1999-1-1

0.015 kg
DIN EN 1999-1-1

0.092 kg
DIN EN 1999-1-1

0.066 kg
DIN EN 1999-1-1

Art. No.

1502832

1502833

1502834

1502835

1502836

Model

Packaging unit
Dimensions (L / W / H)

TRIFLAT holder, top,


15
Flat roof
Any
Module width 790 1050 mm
100 pc.
40 mm / 78 mm / 64 mm

TRIFLAT holder,
bottom, 15
Flat roof
Any
Module width 790 1050 mm
100 pc.
41 mm / 88 mm / 42 mm

Weight
Norms

0.092 kg
DIN EN 1999-1-1

0.066 kg
DIN EN 1999-1-1

TRIFLAT carrier
module, L = 500 mm
Flat roof
Any
Module width 790 1050 mm
100 pc.
500 mm / 63 mm /
43 mm
0.257 kg
DIN EN 1999-1-1

TRIFLAT bracket, 10,


L = 142 mm
Flat roof
Any
Module width 790 1050 mm
25 pc.
142 mm / 47 mm /
192 mm
0.428 kg
DIN EN 1999-1-1

TRIFLAT bracket, 10,


L = 79 mm
Flat roof
Any
Module width 790 1050 mm
50 pc.
79 mm / 44 mm /
185 mm
0.221 kg
DIN EN 1999-1-1

Art. No.

1502837

1502838

1502839

1502840

1502841

Model

TRIFLAT intermediate TRIFLAT series


bracket, 15, L = 100 mm connector, L = 380 mm

TRIFLAT series
connector, L = 680 mm

TRIFLAT series
connector, L = 980 mm

Application
Frame thickness
Module brand

Weight
Norms

Flat roof
Any
Module width 790 1050 mm
100 pc.
100 mm / 45 mm /
110 mm
0.159 kg
DIN EN 1999-1-1

Flat roof
Any
Module width 790 1050 mm
200 pc.
380 mm / 36 mm /
32 mm
0.188 kg
DIN EN 1999-1-1

Flat roof
Any
Module width 790 1050 mm
1 pc.
680 mm / 36 mm /
32 mm
0.336 kg
DIN EN 1999-1-1

Flat roof
Any
Module width 790 1050 mm
1 pc.
980 mm / 36 mm /
32 mm
0.484 kg
DIN EN 1999-1-1

TRIFLAT set rear wall


panel 10, incl.
fastening
Flat roof
Any
Module width 790 1050 mm
10 pc.
920 mm / 45 mm /
215 mm
0.800 kg
DIN EN 1999-1-1

Art. No.

1502842

1502843

1502844

1502845

1502846

Model

TRIFLAT set rear wall


panel 15, incl.
fastening
Flat roof
Any
Module width 790 1050 mm
10 pc.
920 mm / 45 mm /
295 mm
1.100 kg
DIN EN 1999-1-1

TRIFLAT clamp XX =
35 mm

TRIFLAT clamp XX =
38 mm

TRIFLAT clamp XX =
40 mm

TRIFLAT clamp XX =
45 mm

Flat roof
Any
Module width 790 1050 mm
200 pc.
32 mm / 44 mm / 46 mm

Flat roof
Any
Module width 790 1050 mm
200 pc.
32 mm / 47 mm / 46 mm

Flat roof
Any
Module width 790 1050 mm
200 pc.
32 mm / 49 mm / 46 mm

Flat roof
Any
Module width 790 1050 mm
200 pc.
32 mm / 54 mm / 46 mm

0.022 kg
DIN EN 1999-1-1

0.022 kg
DIN EN 1999-1-1

0.022 kg
DIN EN 1999-1-1

0.022 kg
DIN EN 1999-1-1

Application
Frame thickness
Module brand
Packaging unit
Dimensions (L / W / H)

Application
Frame thickness
Module brand

Packaging unit
Dimensions (L / W / H)

Application
Frame thickness
Module brand
Packaging unit
Dimensions (L / W / H)
Weight
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

111

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

On-the-Roof System

Art. No.

1502847

1502848

Model

TRIFLAT clamp XX = 46 mm

...................................................................................................................................................................

1502849

1502850

Application
Frame thickness
Module brand
Packaging unit
Dimensions (L / W / H)
Weight
Norms

TRIFLAT clamp XX = 50 mm TRIFLAT protective building


mat
Flat roof
Flat roof
Flat roof
Any
Any
Any
Module width 790 - 1050 mm Module width 790 - 1050 mm Module width 790 - 1050 mm
200 pc.
200 pc.
1 pc.
32 mm / 55 mm / 46 mm
32 mm / 59 mm / 46 mm
1200 mm / 120 mm / 3 mm
0.022 kg
0.022 kg
0.295 kg
DIN EN 1999-1-1
DIN EN 1999-1-1
-

TRIFLAT protective building


mat, foil-clad
Flat roof
Any
Module width 790 - 1050 mm
1 pc.
14000 mm / 120 mm / 6 mm
7.375 kg
-

Art. No.

1502851

1502857

Model

TRIFLAT earthing plate

1502852

1502856

112

Application
Frame thickness
Module brand
Packaging unit
Dimensions (L / W / H)
Weight
Norms

TRIFLAT bending tool, 2 parts TRIFLAT carrier module,


L = 700 mm
Flat roof
Flat roof
Flat roof
Any
Any
Any
Module width 790 - 1050 mm Module width 790 - 1050 mm Module width 790 - 1050 mm
1 pc.
100 pc.
11 mm / 11 mm / 1 mm
300 mm / 70 mm / 20 mm
700 mm / 63 mm / 43 mm
0.001 kg
0.448 kg
0.360 kg
DIN EN 1993-1-1
DIN EN 1993-1-1
DIN EN 1999-1-1

TRIFLAT rear wall panel


holder
Flat roof
Any
Module width 790 - 1050 mm
100 pc.
82 mm / 49 mm / 3 mm
0.030 kg
DIN EN 1999-1-1

Art. No.

1502858

1502859

1502860

1502861

Model

TRIFLAT cable holder

TRIFLAT self-forming screw

TRIFLAT spacer plate

Application
Frame thickness
Module brand
Packaging unit
Dimensions (L / W / H)
Weight
Norms

TRIFLAT rear wall panel


reinforcement
Flat roof
Flat roof
Flat roof
Flat roof
Any
Any
Any
Any
Module width 790 - 1050 mm Module width 790 - 1050 mm Module width 790 - 1050 mm Module width 790 - 1050 mm
100 pc.
100 pc.
10 pc.
30 mm / 150 mm / 23 mm
30 mm / 11 mm / 11 mm
45 mm / 30 mm / 80 mm
300 mm / 40 mm / 40 mm
0.035 kg
0.006 kg
0.008 kg
0.120 kg
DIN EN 1999-1-1
DIN EN 1993-1-1
DIN EN 1993-1-1
DIN EN 1999-1-1

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

113

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

Trapezoidal Sheet System

...................................................................................................................................................................

TRIVENT mounting system


For trapezoidal sheet roofs
The mounting system

The development of the TRIVENT mounting system


particularly emphasised great exibility, good installation features and great safety. The system was specifically designed for the installation of solar systems on
trapezoidal sheet roofs and combines the above benets into a professional solution.
114

Greatest exibility

The different components of the system allow the


installation on almost any trapezoidal roof. Due to
the TRIVENT support proles with their different
lengths and several drill holes at intervals of 90 mm
to 350 mm, the system can be used for all roof types.
The two versions of the TRIVENT module armatures
can accommodate modules with frame strengths of
35 mm, 40 mm, 46 mm and 50 mm. Additionally, the
system allows for the solar modules to be installed
vertically and horizontally.

The TRIVENT support proles are only riveted to the roof at


the points required by the module installation.

Extremely easy installation

The complete system can be installed on the roof as


simply as possible and with a minimum number of
tools. Having measured the roof and drilled the holes,
the TRIVENT support proles are riveted to the roof.
Then the modules are inserted, followed by the module armatures, and then they are secured at the end of
each row, using the TRIVENT bending tool. Tiresome
screwing in is completely dispensed with. The short
proles and easy-to-handle components enable the
simple and easy transport of the system to and onto
the roof, thus saving energy, time and money.

Best safety

The system, designed for wind and snow loads, provides best stability and safety even in extreme weather
conditions. Each module is secured against slipping
with the TRIVENT retaining rings of the mounting
system. The support proles, bent with the TRIVENT
bending tool, give additional stability to the system
and prevent the slipping of all modules.

The few components of the TRIVENT mounting system


enable the easy, quick and safe installation.

...................................................................................................................................................................
Trapezoidal Sheet System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502634

Model

1502659

1502361

TRIVENT end module


armature (38 and
48 mm)
38 / 48 mm
REC

TRIVENT end module


armature (40 and
50 mm)
40 / 50 mm
Isofoton, Topsolar,
Bisol, Canadian Solar,
Kaneka, MSK, Siliken
Schott, Yingli, Aleo, BP
Solar, Unisolar, EGing,
Advent Solar, Aleo
Solar, Atersa, MDT
technologies, Solara,
Solarfabrik, Solarwatt,
Sunlink PV, Suntech
Power, Sunways
Photovoltaic, Vaillant,
Viessmann

Dimensions (L / W / H)
Weight
Application

TRIVENT end module


armature (35 and
46 mm)
35 / 46 mm
Sanyo, Solarfabrik,
Wrth Solar, Canadian
Solar, DAY4 Energy, GE
Energy, Mitsubishi
Heavy Industries,
Solara, Solarfun Power,
Suntech Power,
Viessmann, Kyocera,
Sharp, Sunpower,
Chaori, Kaneka,
Mitsubishi Electric,
MSK, Sanyo Electric,
Shanghai Chaori Solar
Energy, Vaillant
46 mm / 30 mm / 30 mm 49 mm / 30 mm / 30 mm 50 mm / 30 mm / 30 mm
0.040 kg
0.040 kg
0.040 kg
Trapezoidal sheet roof Trapezoidal sheet roof Trapezoidal sheet roof

Art. No.

1502636

1502660

1502363

Model

TRIVENT middle
module armature (38
and 48 mm)
38 / 48 mm
REC

TRIVENT middle
module armature (40
and 50 mm)
40 / 50 mm
Isofoton, Topsolar,
Bisol, Canadian Solar,
Kaneka, MSK, Siliken
Schott, Yingli, Aleo, BP
Solar, Unisolar, EGing,
Advent Solar, Aleo
Solar, Atersa, MDT
technologies, Solara,
Solarfabrik, Solarwatt,
Sunlink PV, Suntech
Power, Sunways
Photovoltaic, Vaillant,
Viessmann

Dimensions (L / W / H)
Weight
Application

TRIVENT middle
module armature (35
and 46 mm)
35 / 46 mm
Sanyo, Solarfabrik,
Wrth Solar, Canadian
Solar, DAY4 Energy, GE
Energy, Mitsubishi
Heavy Industries,
Solara, Solarfun Power,
Suntech Power,
Viessmann, Kyocera,
Sharp, Sunpower,
Chaori, Kaneka,
Mitsubishi Electric,
MSK, Sanyo Electric,
Shanghai Chaori Solar
Energy, Vaillant
46 mm / 20 mm / 20 mm 49 mm / 20 mm / 20 mm 50 mm / 20 mm / 20 mm
0.026 kg
0.026 kg
0.026 kg
Trapezoidal sheet roof Trapezoidal sheet roof Trapezoidal sheet roof

Art. No.

1502364

1502365

1502366

1502367

1502368

Model

TRIVENT support
prole 070

TRIVENT support
prole 090 - 150

TRIVENT support
prole 180 - 240

TRIVENT support
prole 235 - 295

Frame thickness
Module brand (examples)
Dimensions (L / W / H)

TRIVENT module
armature plate (end
and middle)
All framed modules
50 mm / 40 mm / 30 mm

Weight
Application

0.016 kg
Trapezoidal sheet roof

All framed modules


100 mm / 60 mm /
30 mm
0.077 kg
Trapezoidal sheet roof

All framed modules


230 mm / 60 mm /
30 mm
0.177 kg
Trapezoidal sheet roof

All framed modules


320 mm / 60 mm /
30 mm
0.246 kg
Trapezoidal sheet roof

All framed modules


385 mm / 60 mm /
30 mm
0.289 kg
Trapezoidal sheet roof

Frame thickness
Module brand (examples)

Frame thickness
Module brand (examples)

1502635

1502360

TRIVENT end module


armature (34 and
45 mm)
34 / 45 mm
SolarWorld, Hareon
Solar, Jinko, JA Solar

TRIVENT end module


armature (31 and
42 mm)
31 / 42 mm
SolarWorld

1502637

1502362

TRIVENT middle
module armature (34
and 45 mm)
34 / 45 mm
SolarWorld, Hareon
Solar, Jinko, JA Solar

TRIVENT middle
module armature (31
and 42 mm)
31 / 42 mm
SolarWorld

58 mm / 30 mm / 30 mm 60 mm / 30 mm / 30 mm
0.040 kg
0.040 kg
Trapezoidal sheet roof Trapezoidal sheet roof

58 mm / 20 mm / 20 mm 60 mm / 20 mm / 20 mm
0.026 kg
0.026 kg
Trapezoidal sheet roof Trapezoidal sheet roof

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

115

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

Trapezoidal Sheet System

...................................................................................................................................................................

Art. No.

1502369

1502370

1502371

1502372

1502378

Model

TRIVENT rubber seal


(2 per support prole)
All framed modules
30 mm / 20 mm / 1 mm

TRIVENT sealing rivets


(2 per support prole)
All framed modules
50 mm / 5 mm / 5 mm

TRIVENT retaining
rings (2 per module)
All framed modules
30 mm / 30 mm / 2 mm

TRIVENT edge clip


All framed modules
18 mm / 15 mm / 11 mm

Weight
Application

TRIVENT support
prole 290 - 350
All framed modules
430 mm / 60 mm /
30 mm
0.331 kg
Trapezoidal sheet roof

0.002 kg
Trapezoidal sheet roof

0.004 kg
Trapezoidal sheet roof

0.010 kg
Trapezoidal sheet roof

0.001 kg
Trapezoidal sheet roof

Accessories
Art. No.
1502373

Model
TRIVENT drilling gauge

Frame thickness
Module brand (examples)
Dimensions (L / W / H)

116

1502374

TRIVENT bending tool

1502379

TRIVENT riveting machine


PowerBird, (rivet 6.3 mm)
TRIVENT PowerBird
rechargeable battery 12V 2A

1502408

Description
For the measuring of the
TRIVENT system
Special tool for horizontal
xing
TRIVENT accessories, rivet
diameter 6.3 mm
TRIVENT accessories, rivet
diameter 6.3 mm

Dimensions (L / W / H)
Weight
2000 mm / 1000 mm / 100 mm 2.5 kg (approx.)
300 mm / 30 mm / 30 mm

0.5 kg (approx.)

500 mm / 500 mm / 100 mm

4.2 kg (approx.)

100 mm / 100 mm / 100 mm

1.2 kg (approx.)

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

117

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

Roof-integrated System

...................................................................................................................................................................

TRIROOF
The exible roof integration system
Compatibility and exibility

118

TRIROOF offers unlimited freedom when choosing


modules: The mounting system is suited for all framed
module types of all module manufacturers in the
TRITEC range. The simple insertion system was designed to be used independent of the module manufacturer. Thus, framed standard modules can be integrated into the roof. The mounting system is supplied
as a complete set. This includes as standard also the
edge connection plates, in addition to the proles and
insertion rails. The plates can be adjusted to the respective module size and thus offer the greatest exibility
possible.

Impermeability and resilience

The roof integration system TRIROOF replaces the


existing roong completely. The bulk of the rain water
is discharged from the PV modules. The remaining
water is collected and drained off in the specically
developed water-bearing carrier proles, so that the
impermeability of the roof is ensured. All TRIROOF
components are optimally designed for wind and
snow loads and are resistant to even extreme weather
conditions.

Maximum stability of the mounting system

Aesthetics and simplicity

The edge connection plates are made from aluminium


and have an anthracite coating. Combined with black
anodised insertion proles and modules with black
frames, every roof receives an aesthetically sophisticated PV system. The installation of the modules does
not require screws: they are locked into the insertion
proles by gravity. In addition to giving a pleasing
visual effect, this also enables the modules to be removed and inserted again during maintenance work.

Quality and safety

TRITEC guarantees the highest quality and greatest


safety. All proles and accessories manufactured under
the original label TRIROOF carry a manufacturer's
guarantee of 5 years from the date of delivery. This
guarantee covers both sound condition and technical
efciency of the products. The system is planned and
calculated with extraordinary efciency using the
TRIDESIGN dimensioning software, thus ensuring optimal design and best safety.

Simple insertion of the modules

...................................................................................................................................................................
Roof-integrated System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1502513

Model

TRIROOF universal
prole UP-I, 6.000 m

Application
Dimensions (L / W / H)
Weight *
Norms
Art. No.

1502518

1502523

1502528

1502534

TRIROOF universal
prole UP-I, 6.000 m,
inside milling
In-roof
In-roof
6000 mm / 170 mm /
6000 mm / 170 mm /
41 mm
41 mm
3.800 kg
3.800 kg
IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16),
TV
TV

TRIROOF universal
prole UP-I, 6.000 m,
outside milling
In-roof
6000 mm / 170 mm /
41 mm
3.800 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF universal
prole UP-I, 6.000 m,
double milling
In-roof
6000 mm / 170 mm /
41 mm
3.800 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF horizontal
prole TR-H, 4.900 m
In-roof
4900 mm / 139 mm /
22 mm
1.130 kg
IEC 61215 ed. 2 (10.16),
TV

1502544

1502550

1502551

1502552

1502545

119

Model

TRIROOF xing clip


TRC
In-roof
105 mm / 18 mm /
14 mm
0.010 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF ridge plate


right FR
In-roof
1230 mm / 560 mm /
88 mm
0.028 kg
1.440 kg
IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16),
TV
TV

TRIROOF ridge plate


centre FM
In-roof
2480 mm / 557 mm /
88 mm
3.000 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF ridge plate


left FL
In-roof
1230 mm / 560 mm /
88 mm
1.440 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502554

1502555

1502556

1502557

1502558

Model

TRIROOF side plate top


right SOR
In-roof
2480 mm / 300 mm /
40 mm
1.520 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF side plate top


left SOL
In-roof
2480 mm / 300 mm /
40 mm
1.520 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF side plate


right SR
In-roof
2330 mm / 285 mm /
40 mm
1.440 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF side plate left


SL
In-roof
2330 mm / 285 mm /
40 mm
1.440 kg
IEC 61215 ed. 2 (10.16),
TV

TRIROOF side plate


bottom right SUR
In-roof
2330 mm / 285 mm /
40 mm
1.430 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502559

1502560

1502561

1502562

1502622

Model

TRIROOF side plate


bottom left SUL

TRIROOF end plate side TRIROOF end plate


AS
bottom AU

Application
Dimensions (L / W / H)
Weight *
Norms

Application
Dimensions (L / W / H)
Weight *
Norms

Application
Dimensions (L / W / H)
Weight *
Norms

TRIROOF universal
prole retainer TR-U
In-roof
45 mm / 35 mm / 15 mm

TRIROOF plate retainer TRISTAND insertion


prole TS-31, 6.000 m,
blank aluminium
In-roof
In-roof
In-roof
In-roof
In-roof
2330 mm / 285 mm /
2480 mm / 285 mm /
2480 mm / 285 mm /
82 mm / 25 mm / 16 mm 6000 mm / 54 mm /
40 mm
45 mm
45 mm
47 mm
1.430 kg
0.500 kg
0.390 kg
0.004 kg
1.195 kg
IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16), IEC 61215 ed. 2 (10.16),
TV
TV
TV
TV
TV

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
MOUNTING SYSTEMS COMPONENTS

Roof-integrated System

...................................................................................................................................................................

Art. No.

1502199

1502200

1502798

1502201

1502202

Model

TRISTAND insertion
prole TS-34, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
50 mm
1.107 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-35, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
51 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-38, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-42, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502661

1502203

1502204

1502623

1502205

Model

TRISTAND insertion
prole TS-45, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
61 mm
1.196 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-50, 6.000 m,
blank aluminium
In-roof
6000 mm / 54 mm /
66 mm
1.236 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-31, 6.000 m,
black
In-roof
6000 mm / 54 mm /
47 mm
1.195 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-34, 6.000 m,
black
In-roof
6000 mm / 54 mm /
50 mm
1.107 kg
IEC 61215 ed. 2 (10.16),
TV

Art. No.

1502206

1502799

1502207

1502208

1502209

Model

TRISTAND insertion
prole TS-35, 6.000 m,
black
In-roof
6000 mm / 54 mm /
50 mm
1.115 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-38, 6.000 m,
black
In-roof
6000 mm / 54 mm /
54 mm
1.139 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-40, 6.000 m,
black
In-roof
6000 mm / 54 mm /
56 mm
1.155 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-42, 6.000 m,
black
In-roof
6000 mm / 54 mm /
58 mm
1.172 kg
IEC 61215 ed. 2 (10.16),
TV

TRISTAND insertion
prole TS-46, 6.000 m,
black
In-roof
6000 mm / 54 mm /
62 mm
1.204 kg
IEC 61215 ed. 2 (10.16),
TV

Application
Dimensions (L / W / H)
Weight *
Norms

120

Application
Dimensions (L / W / H)
Weight *
Norms

Application
Dimensions (L / W / H)
Weight *
Norms
Art. No.

1502210

1502211

1502214

1502307

Model
Application
Dimensions (L / W / H)
Weight *
Norms

TRISTAND insertion prole


TS-50, 6.000 m, black
In-roof
6000 mm / 54 mm / 66 mm
1.236 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND middle rail TS-M,


6.000 m, blank aluminium
In-roof
6000 mm / 85 mm / 17 mm
0.775 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND end bracket TS-E,


blank aluminium
In-roof
32 mm / 29 mm / 33 mm
0.010 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND end bracket TS-E,


black
In-roof
32 mm / 29 mm / 33 mm
0.010 kg
IEC 61215 ed. 2 (10.16), TV

Art. No.

1502215

1502216

1502217

1502777

Model

TRISTAND SafeClick SC
In-roof
13 mm / 45 mm / 70 mm
0.050 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND universal prole


connector UP-C
In-roof
120 mm / 51 mm / 41 mm
0.130 kg
IEC 61215 ed. 2 (10.16), TV

TRISTAND bending tool

Application
Dimensions (L / W / H)
Weight *
Norms

TRISTAND insertion prole


connector TS-C
In-roof
95 mm / 64 mm / 17 mm
0.080 kg
IEC 61215 ed. 2 (10.16), TV

In-roof
292 mm / 18 mm / 6 mm
0.231 kg
IEC 61215 ed. 2 (10.16), TV
Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
Roof-integrated System

MOUNTING SYSTEMS COMPONENTS

...................................................................................................................................................................

Art. No.

1302257

1302258

1502245

1502246

Model

TRISTAND grounding clamp


for insertion prole TS
In-roof
16 mm / 10 mm / 13 mm
0.002 kg
IEC 60439-1 (2004), NF EN
60068-2-11 (1999)

TRISTAND grounding clamp


for connector TSC
In-roof
21 mm / 10 mm / 13 mm
0.002 kg
IEC 60439-1 (2004), NF EN
60068-2-11 (1999)

TRISTAND cross cable clip


block UP-K
In-roof
22 mm / 22 mm / 16 mm
0.002 kg
IEC 61215 ed. 2 (10.16), TV

In-roof
18 mm / 15 mm / 11 mm
0.001 kg
IEC 61215 ed. 2 (10.16), TV

Description
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF
For TRIROOF

edge
edge
edge
edge
edge
edge
edge
edge
edge
edge
edge
edge
edge
edge

Application
Dimensions (L / W / H)
Weight *
Norms

TRISTAND edge clip TSEC

* - Per meter
Accessories
Art. No.
1502563
1502564
1502565
1502566
1502567
1502546
1502547
1502548
1502549
1502553
1502640
1502646
1502647
1502648

Model
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF
TRIROOF

Clean edge nish of the system

gland 4.5 x 35 A2, drill bit


roof connecting tape Perform, 4 m x 45 cm
special adhesive for ridge plates
adhesive for roof connecting tape Perform
adhesive tape FLEX-DICHT 3D
Z adapter TR-Z
round head screw 5.0 x 30 A2, for TR-U
round head screw 3.0 x 30 A2, for retainer
hammer-head screw M10 x 20 A2
ridge plate joint cover FS
hexagon set screw M10 x 25 A2
stainless steel rivet 3.2 x 6, for sheets
drill 3.3 mm for stainless steel rivet
collar sealing strip

Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting
Mounting

System
System
System
System
System
System
System
System
System
System
System
System
System
System

cover
cover
cover
cover
cover
cover
cover
cover
cover
cover
cover
cover
cover
cover

Optimal and aesthetically pleasing integration of the


system into the roof

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

121

Mounting Systems
Applications
TRISTAND, TRISTAND Aero, TRISTAND East-West,
TRIFLAT South, TRIFLAT East-West, TRIROOF and
TRIVENT are versatile, easy-to-install mounting systems
for numerous applications. They provide solutions for
virtually any type of roof both for standard installations
and special applications.

I. PITCHED ROOF: ROOF-TOP


II. PITCHED ROOF: ELEVATION
III. PITCHED ROOF: ROOF-INTEGRATED
IV. FLAT ROOF
V. FACADE

123

MOUNTING SYSTEMS APPLICATIONS I. PITCHED ROOF: ROOF-TOP 1. Tiles, shingles, corrugated panels

1.1 TRI-STAND on tiles | 1.1.1 Insertion system


11.5
odule +

mm) *

(m

module
69

35.7

ile

TS prof

ules + 69

r of mod

numbe

69

- 57.5 m

module
ule
PV mod
S
P or UPUP-L, U

8.5 3

69

mm
module

- 57.5 m

11.5

33.3

module
ule

PV mod

.5 mm

+ 11
module

124

POTENTIAL APPLICATIONS
for standard tiles
for flat beaver tail tiles
for shingles and slate
ADVANTAGES
Insertion system
time-saving no-screw module installation
homogeneous appearance due to small spaces between module rows
easy removal of modules for replacement or maintenance work
no clip marks
optimum load distribution
Flexibility
different profile gauges for both light-weight designs and statically optimized constructions
one or several roof hook variants for virtually any application
optionally black profiles for visually attractive systems with black modules
horizontal and vertical module installation
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C / TS-C profile connector
TS insertion profile
TS central rail

roof hooks
TS edging tool

the basic profile


profile for high static loads
material-optimized profile
secure connection of profiles
insertion profile for standard frame heights
additional reinforcement for vertical module insertion
and a pressure load assumption of over 2,400 N/m
variable or fixed, for loads of up to 170 kg per roof hook
for edge-trimming the profiles

1. Tiles, shingles, corrugated panels I. PITCHED ROOF: ROOF-TOP MOUNTING SYSTEMS APPLICATIONS

1.1 TRI-STAND on tiles | 1.1.2 Clip system


ule

PV mod

ule

PV mod
UP-S
, UP or

UP-L

125

POTENTIAL APPLICATIONS

for standard tiles


for flat beaver tail tiles
for shingles
for large rafter spacings

ADVANTAGES
Clip system
materials-saving
manufacturer-conforming mode of installation
low system costs per kWp
standard on the European market
For large rafter spacings since, by clipping, the module supports the system statics.
Flexibility
different profile gauges for both light-weight designs and statically optimized constructions
one or several roof hook variants for virtually any application
optionally black profiles and clamps for visually attractive systems with black modules
horizontal and vertical module installation
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C profile connector
roof hooks

the basic profile


profile for high static loads
material-optimized profile
secure connection of profiles
variable or fixed, for loads of up to 170 kg per roof hook

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS I. PITCHED ROOF: ROOF-TOP 1. Tiles, shingles, corrugated panels

1.2 TRI-STAND on shingles

(modu

69
35.7

- 57.5 m

module

+ 69 m

69
m

57.5 m
odule -

m
69

module

odules

ber of m

) * num

.5 mm
le + 11

8.5 3

11.5

33.3

module
ule

PV mod

ule

PV mod

le
TS profi

126

POTENTIAL APPLICATIONS
On all types of shingle roofs with hanger bolts
To be taken into account here:
Fastening of counter-battening (min. 45/45 mm) must be able to withstand the additional loads.
Set screws must be centrically set into the counter-battening.
Asbestos-containing roof shingles may only be worked on in compliance with standard regulations.
ADVANTAGES
Module installation
Insertion system: optimum load distribution and time-saving no-screw installation
Clip system: materials-saving mode of installation and low system costs per kWp
Flexibility
optionally black profiles and clamps for visually attractive systems with black modules
horizontal and vertical module installation
different profile gauges for both light-weight designs and statically optimized constructions
freely selectable degree of ventilation
Quality
no quality impairment of the subroof due to fastening screws in counter-battening
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C / TS-C profile connector
hanger bolts
TS central rail
TS edging tool

the basic profile


profile for high static loads
material-optimized profile
secure connection of profiles
specifically for fiber cement shingles
possibly required for insertion system
for edge-trimming the profiles

1. Tiles, shingles, corrugated panels I. PITCHED ROOF: ROOF-TOP MOUNTING SYSTEMS APPLICATIONS

1.3 TRI-STAND on corrugated panel roofs


69

(module

module

35.7
le

TS profi

number

9 mm

ules + 6

of mod

module

-5

module

69

11.5

33.3

8.5 3

- 57.5 m
module

69

m) *
11.5 m

7.5 mm

ule

PV mod

ule
PV mod
S
P or UP-

UP-L, U

127

POTENTIAL APPLICATIONS
for all types of pitched roofs with profiled or corrugated surfaces
for corrugated panels
for corrugated fiber cement panels
ADVANTAGES
Module installation
Insertion system: optimum load distribution and time-saving no-screw installation
Clip system: materials-saving mode of installation and low system costs per kWp
Flexibility
optionally black profiles and clamps for visually attractive systems with black modules
different profile gauges for both light-weight designs and statically optimized constructions
horizontal and vertical module installation
Different hanger bolt sizes allow for a freely selectable degree of ventilation and the correction of roof
irregularities
Quality
solid fastening even for comparatively thick and soft insulation layers
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C / TS-C profile connector
hanger bolts
TS central rail
TS edging tool

the basic profile


profile for high static loads
material-optimized profile
secure connection of profiles
in different sizes (M8, M10, M12)
possibly required for insertion system
for edge-trimming the profiles

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS I. PITCHED ROOF: ROOF-TOP 2. Trapezoidal sheet metal roof

2.1 TRI-VENT | 2.1.1 Horizontal installation

- 20
odules

r of m
numbe
le
+ 20) *
le
u
d
f modu
o
of m
width o
(width
0
2
le
f modu
width o

(in mm

le

f modu

20

width o

20

128

POTENTIAL APPLICATIONS
on trapezoidal sheet metal roofs
on sandwich elements
applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths
ADVANTAGES
Installation
riveting instead of bolting carrier profiles for higher loads up to 2400 N/m2
low cost and uncomplicated shipment thanks to few components and short profiles
No consequences due to heat expansion: Modules are set on short rails, tension-free and without clipping
suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses
installation possible by 1 person
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

central and end module anchor


carrier profile
sealing rivets
drilling gauge
TRI-VENT bending tool

each applicable for two different module widths


available in different lengths
for fastening the carrier profiles
for optimum alignment of drill holes
for secure fixation of end module anchors

2. Trapezoidal sheet metal roof I. PITCHED ROOF: ROOF-TOP MOUNTING SYSTEMS APPLICATIONS

2.1 TRI-VENT | 2.1.2 Vertical installation

mber
0) * nu
ule + 2
of mod
th
g
n
e
(l
ule
of mod
length
ing
le spac
tion ho

installa

of mo

upper in

20

stal.
lower in

n hole

stallatio

mm)

spacing

stal.

upper in

20

nh

stallatio

lower in

ing
ole spac

20 (in
dules -

129

POTENTIAL APPLICATIONS

on trapezoidal sheet metal roofs


on sandwich elements
applicable at all bead spacings between 90 and 350 mm due to carrier profiles of different lengths
suitable for uneven roofs

ADVANTAGES
Installation
riveting instead of bolting carrier profiles for higher loads up to 2400 N/m2
low cost and uncomplicated shipment thanks to few components and short profiles
No consequences due to heat expansion: Modules are set on short rails, tension-free and without clipping
no slipping of modules due to circlips
suitable for virtually any trapezoidal sheet metal roof and modules of different frame thicknesses
installation possible by 1 person
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

central and end module anchor


carrier profile
sealing rivets
drilling gauge
circlips
TRI-VENT bending tool

each applicable for two different module widths


available in different lengths
for fastening the carrier profiles
for optimum alignment of drill holes
2 pieces per module, suitable for all framed modules
for secure fixation of end module anchors

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS I. PITCHED ROOF: ROOF-TOP 2. Trapezoidal sheet metal roof

2.2 TRI-STAND
2.2.1 Insertion system with rivet SafeClick

mber of

height

ld =
odule fie

(length

rtion +

ule inse

of mod

* nu
.5 mm)

modules

+ 69 m

11

of m

th of
ing = leng

module

insertion

m)

+ 11.5 m

le spac

drilling ho

130

POTENTIAL APPLICATIONS
on trapezoidal sheet metal roofs
on sandwich elements
ADVANTAGES
Insertion system
time-saving no-screw module installation
homogeneous appearance due to small spaces between module rows
easy removal of modules for replacement or maintenance work
to clip marks
optimum load distribution
Installation
quick and easy since only one setting is required for the drilling gauge
module load possible up to 5400 N/m2
location-optimized load distribution to all outward beads thanks to continuous rails
Flexibility
horizontal and vertical module installation
Number of rivet SafeClick is selected depending on roof load, bead space, trapezoidal sheet metal gauge and material (aluminium or steel).
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

TS profile
TS-M central rail
rivet SafeClick
drilling gauge
rubber seal and rivet
TS edging tool

in aluminium or black
for TRI-STAND insertion profiles
quick and stable joining of SafeClick connections
for optimum calibration of drill holes
for optimum impermeability of the roof
for edge-trimming the profiles when using insertion system

2. Trapezoidal sheet metal roof I. PITCHED ROOF: ROOF-TOP MOUNTING SYSTEMS APPLICATIONS

2.2 TRI-STAND
2.2.2 Clip system with rivet SafeClick

(length
length

length

ule / 5

length

ule
of mod

ule *
of mod

0.6

of

+
module

of
length

umber
20) * n
20
/5
module

odule
th of m

/5

* 2 + 20

20

m)

0 (in m

ules - 2

of mod

length

ule / 5

of mod

(in mm

odule /

of m
length

leng

of mod

131

POTENTIAL APPLICATIONS
on trapezoidal sheet metal roofs
on sandwich elements
ADVANTAGES
Clip system
materials-saving
manufacturer-conforming mode of installation
low system costs per kWp
standard on the European market
Installation
vertical module installation
module load possible up to 5400 N/m2
location-optimized load distribution to all outward beads thanks to continuous rails
Flexibility
In case of interfering objects, the position of a UP-TS profile may be slightly changed without
displacement of the entire module field.
Number of rivet SafeClick is selected depending on roof load, bead space, trapezoidal sheet metal
gauge and material (aluminium or steel).
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

center clips
UP-TS profile
rivet SafeClick
drilling gauge

in aluminium or black
carrier profile for modules
quick and stable joining of SafeClick connections
for optimum calibration of drill holes

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS I. PITCHED ROOF: ROOF-TOP 3. Sheet metal roof

3.1 TRI-STAND
3.1.1 Insertion system on sheet metal folding clamps
odules

ber of m

height
module

ngth
eld = (le

of

fi
module

rtion +

ule inse

of mod

* num
.5 mm)

11

6.9

+ 69 m

- 57.5
module

mm

6.9

mm
le - 57.5

modu

6.9
m

- 57.5 m

6.9
S

P or UP-

UP-L, U

132

POTENTIAL APPLICATIONS
on sheet metal and Kalzip roofs by means of fastening on standing seams
with module installation in rows suitable for curved roof surfaces
ADVANTAGES
Insertion system
time-saving no-screw module installation
homogeneous appearance due to small spaces between module rows
easy removal of modules for replacement or maintenance work
no clip marks
optimum load distribution
Flexibility
optionally black profiles for visually attractive systems with black modules
horizontal and vertical module installation
clips fitting for different module frames
fastening with flat head screws or hammerhead bolts
Quality
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

sheet metal and Kalzip clamps


UP universal profile
UP-S universal profile
UP-L universal profile
TS edging tool

depending on type of roof, for different module frames


the basic profile
profile for high static loads
material-optimized profile
for edge-trimming the profiles with insertion system

3. Sheet metal roof I. PITCHED ROOF: ROOF-TOP MOUNTING SYSTEMS APPLICATIONS

3.1 TRI-STAND
3.1.2 Clip system on sheet metal folding clamps

20

P or UP-

UP-L, U

133

POTENTIAL APPLICATIONS
on sheet metal and Kalzip roofs by means of fastening on standing seams
ADVANTAGES
Clip system
materials-saving
manufacturer-conforming mode of installation
low system costs per kWp
standard on the European market
Flexibility
optionally black profiles and clamps for visually attractive systems with black modules
horizontal and vertical module installation
clips fitting for different module frames
fastening with flat head screws or hammerhead bolts
Quality
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

sheet metal and Kalzip clamps


UP universal profile
UP-S universal profile
UP-L universal profile

depending on type of roof, for different module frames


the basic profile
profile for high static loads
material-optimized profile

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS II. PITCHED ROOF: ELEVATION

1. TRI-STAND triangle installation with hanger bolts


90

le

du

mo

.5
11

75

ule

mm

+6

mm

shading angle

mm

-5

d
mo

-L,

UP

UP

or

-S

UP

134

POTENTIAL APPLICATIONS
as support on pitched roofs with up to 20 inclination
for southern orientation on north/east/west roofs
ADVANTAGES
Insertion system
time-saving no-screw module installation
easy removal of modules for replacement or maintenance work
homogeneous appearance due to small spaces between module rows
no clip marks
optimum load distribution
Flexibility
horizontal and vertical module installation
flexible module inclinations (20/30, 20 70) for optimum yield depending on location
also suitable for zones with high snow and wind loads (with central rail)
Quality
excellent inherent stability due to solid construction
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
TS profile
standard angle
FlexFix angle
SafeClick
hanger bolts
TS edging tool

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
insertion profile
fixed support angle 20 or 30
freely selectable angle between 20 and 70
secure profile connection
for fastening to the substructure on the roof
for edge-trimming the profiles

II. PITCHED ROOF: ELEVATION MOUNTING SYSTEMS APPLICATIONS

2. TRI-STAND triangle installation with roof hooks


m

le -

5m

57

u
od

90

le +

du

mo

5
11

mm
le -

+6

57

mm

shading angle

mm

du

mo

135

POTENTIAL APPLICATIONS
as support on pitched roofs with up to 20 inclination
for southern orientation on north/east/west roofs
ADVANTAGES
Insertion system
time-saving no-screw module installation
easy removal of modules for replacement or maintenance work
homogeneous appearance due to small spaces between module rows
no clip marks
optimum load distribution
Flexibility
horizontal and vertical module installation
flexible module inclinations (20/30, 20 70) for optimum yield depending on location
also suitable for zones with high snow and wind loads (with central rail)
Quality
excellent inherent stability due to solid construction
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
TS profile
standard angle
FlexFix angle
SafeClick
hanger bolts
TS edging tool

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
insertion profile
fixed support angle 20 or 30
freely selectable angle between 20 and 70
secure profile connection
for fastening to the substructure on the roof
for edge-trimming the profiles

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS III. PITCHED ROOF: ROOF-INTEGRATED

1. TRI-ROOF on wooden purlins


69

ule

mod

.5 m

- 57

69

le
odu

(m

ule

mod

.5
+ 11
.5

- 57

)*n

mm

dule

f mo

ro
mbe

m
+ 69
ule

mod

.5 m

- 57

69

mm

69
ule

mod

136

.5
- 57

mm

69

POTENTIAL APPLICATIONS

with roof refurbishment and new roofs


in combination with existing roof areas or as roof coverage over the whole area
with purlin spaces of up to 2.5 m
suitable for zones with high snow and wind loads (with central support)

ADVANTAGES
Flexibility
Insertion system: easy replacement of modules
compatible with framed standard modules
optionally black profiles for visually attractive systems with black modules
Impermeability
discharge of rain water for the most part via modules
specially developed water-bearing carrier profiles
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS
UP-I universal profile
TR-H profile

basic profile for vertical water drainage


profile for horizontal water drainage

100

III. PITCHED ROOF: ROOF-INTEGRATED MOUNTING SYSTEMS APPLICATIONS

2. TRI-ROOF on steel purlins


00

69 1

ule

mod

.5 m

- 57

69

dule

(mo

n
m) *
.5 m
+ 11 .5 mm
ule

mod

s+

dule

f mo

ro
mbe

m
69 m
ule

mod

.5

- 57

mm

69

- 57

69

ule

mod

.5

- 57

mm

69

137

POTENTIAL APPLICATIONS

with roof refurbishment and new roofs


in combination with existing roof areas or as roof coverage over the whole area
with purlin spaces of up to 2.5 m
suitable for zones with high snow and wind loads (with central support)

ADVANTAGES
Flexibility
Insertion system: easy replacement of modules
compatible with framed standard modules
optionally black profile for visually attractive systems with black modules
Impermeability
discharge of rain water for the most part via modules
specially developed water-bearing carrier profiles
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS
UP-I universal profile
TR-H profile

basic profile for vertical water drainage


profile for horizontal water drainage

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS III. PITCHED ROOF: ROOF-INTEGRATED

3. TRI-ROOF on tile battening


b
69

e - 57

17

.5 m

ul
mod

s+

dule

f mo

m) *

.5 m

le
odu

(m

ule -

57.5

+ 11

nu

ro
mbe

69 m

69

.5 m

e - 57

ul
mod

69

mm

mod

-235

69

00
0 1

10

10

138

POTENTIAL APPLICATIONS

with roof refurbishment and new roofs


in combination with existing roof areas or as roof coverage over the whole area
with purlin spaces of up to 2.5 m
suitable for zones with high snow and wind loads (with central support)

ADVANTAGES
Flexibility
Insertion system: easy replacement of modules
compatible with framed standard modules
with standard tile cover, supply of complete sheet metal flashing which can be adjusted to the module
size without special know-how
optionally black profiles for visually attractive systems with black modules
Impermeability
discharge of rain water for the most part via modules
specially developed water-bearing carrier profiles
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP-I universal profile


TR-H profile
ridge and lateral flashings
accessories for sealing

basic profile for vertical water drainage


profile for horizontal water drainage
optional with standard tiles
valley sealing strips, special adhesive, adhesive tape FLEX-DICHT

1. Flat roofs with low load capacity IV. FLAT ROOF MOUNTING SYSTEMS APPLICATIONS

1.1 TRI-STAND Aero


for

ule

mod

ths

wid

10
90-8

mm

and

0m

-101

990

shading angle

ballast

ballast

calculation as a function of the shading angle

(Aero 80) 859 mm, (Aero 100) 1062 mm

(Aero 80) 859 mm, (Aero 100) 1062 mm

hexagonal screw M10x25 A2


hexagonal screw M10x25 A2
hammer head bolt M10x20 A2
No Regupol protective strips
between module rows!

Regupol protective strip

hammer head bolt M10x20 A2

hammer head bolt M10x20 A2

Regupol protective strip

POTENTIAL APPLICATIONS
up to max. 5 roof inclination with horizontal module installation
with film cover or bitumen
gravel-covered roofs or green roof areas
ADVANTAGES
Installation
fast module installation with few components; yet more time-saving with preassembled supports
no penetration of roof membrane
possible module load of up to 5,400 N/m2
manufacturer-conforming module installation at installation drill holes
suitable for standard modules of a width of 790 to 820 mm and 990 to 1010 mm
Ballast
aerodynamically optimized for flat roofs with low load capacity
low net weight
flexible weighting on the rear by means of concrete slabs or flagstones
reduced dynamic and wind pressure load by means of wind deflector
Quality
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C connector
TS-F angle
wind baffle plate
regupol film

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
if necessary for the connection of continuous rails
fixed 20 inclination for optimum shading clearance
in two standard designs
for optimum roof protection

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

139

MOUNTING SYSTEMS APPLICATIONS IV. FLAT ROOF 1. Flat roofs with low load capacity

1.2 TRI-STAND East-West

140

POTENTIAL APPLICATIONS
for PV systems with an east-west exposure
gravel roofs and green roof areas
trapezoidal sheet metal and standing seam roofs
ADVANTAGES
Installation
insertion system: optimum load distribution and time-saving no-screw installation
clip system: materials-saving mode of installation and low system costs per kWp
no penetration of roof membrane
possible module load of up to 5,400 N/m2
low expenditures for materials and installation due to plug-in system
Ballast
aerodynamically optimized for flat roofs with low load capacity
flexible weighting on the rear by means of concrete slabs or flagstones
Quality
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN dimensioning software for optimum, standard planning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
support angle
UP-TS profile

the basic profile


profile for high static loads, required depending on design
material-optimized profile
10 and 20
for installation on trapezoidal sheet metal roof

1. Flat roofs with low load capacity IV. FLAT ROOF MOUNTING SYSTEMS APPLICATIONS

1.3 TRI-FLAT South

ab 972

130
120
100
90
80
50
40
0

220

279

398

458

518

696

756

141

POTENTIAL APPLICATIONS

for PV systems on flat roofs with southern orientation


foil roofs
concrete and gravel roofs
roofs with substrate and green cover
up to max. 5 roof inclination

ADVANTAGES
Mounting
suited for framed module in horizontal mounting
installation by means of a simple click system with few tools
simple module clipping using a click system
Logistics
easy warehousing: components fit on Euro pallets and are stackable
low-cost transport due to few and short components (< 1,20 m)
Quality
components of high-quality aluminium and V2A stainless steel
10-year guarantee
successful wind channel test
MOST IMPORTANT COMPONENTS

module clip
rear wall panel
bracket / intermdiate bracket
bending tool

for no-tool installation


guarantees low ballast through aerodynamics
for 10/15 support
for profile connection

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS IV. FLAT ROOF 1. Flat roofs with low load capacity

1.4 TRI-FLAT East-West

POTENTIAL APPLICATIONS

for PV systems on flat roofs with an east-west orientation


foil roofs
concrete and gravel roofs
roofs with substrate and green cover
up to max. 5 roof inclination

ADVANTAGES
Mounting
suited for framed module in horizontal mounting
installation by means of a simple click system with few tools
simple module clipping using a click system
Logistics
easy warehousing: components fit on Euro pallets and are stackable
low-cost transport due to few and short components (< 1,20 m)
Quality
components of high-quality aluminium and V2A stainless steel
10-year guarantee
successful wind channel test
MOST IMPORTANT COMPONENTS

module clip
rear wall panel
bracket / intermdiate bracket
bending tool

for no-tool installation


guarantees low ballast through aerodynamics
for 10/15 support
for profile connection

172

220

130
120
100
90
80
50
40
0

316

363

411

602

142

554

ab 786

2. Flat roofs with normal load capacity IV. FLAT ROOF MOUNTING SYSTEMS APPLICATIONS

2.1 TRI-STAND triangle installation on Renosol plates


m

0m

ule

mod

+ 69

m
.5 m

+ 11

5m

- 57

le
odu

shading angle

P or

L, U

UP-

UP-

Renosol panels 800x600x35

143

POTENTIAL APPLICATIONS
roof areas with gravel, granulate, bitumen or film cover
for additional module inclinations on pitched roofs with up to 20 roof pitch
gravel-covered roofs or green roof areas
ADVANTAGES
Insertion system
time-saving no-screw module installation
easy removal of modules for replacement or maintenance work
homogeneous appearance due to small spaces between module rows
no clip marks
optimum load distribution
Flexibility
horizontal and vertical module installation
flexible module inclinations (20/30, 20 70) for optimum yield depending on location
Quality
excellent inherent stability due to solid construction
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
TS profile
standard angle
FlexFix angle
SafeClick
Renosol plates
TS edging tool

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
insertion profile
fixed support angle 20 or 30
freely selectable angle between 20 and 70
secure profile connection
for fastening to the substructure on the roof
for edge-trimming the profiles

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS IV. FLAT ROOF 2. Flat roofs with normal load capacity

2.2 TRI-STAND upright installation


m

0m

ule

mod

144

m
.5 m

+ 11

+ 69

75 m

-5
dule

shading angle

mo

Renosol panel 800x600x35

POTENTIAL APPLICATIONS
flat roofs with inclinations from -5 to +5
roof areas with gravel, granulate, bitumen or film cover
for green roofs, uneven roofs and locations with heavy snowfall
ADVANTAGES
Insertion system
time-saving no-screw module installation
easy removal of modules for replacement or maintenance work
homogeneous appearance due to small spaces between module rows
no clip marks
optimum load distribution
Installation
horizontal and vertical module installation
flexible module inclinations (20/30) for optimum yield depending on location
large distance of modules to the roof, thus less shading
Quality
excellent inherent stability due to solid construction
TV certified
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
TS profile
standard angle
SafeClick
Renosol plates
TS edging tool

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
insertion profile
fixed support angle 20 or 30
secure profile connection
for fastening to the substructure on the roof
for edge-trimming the profiles

V. FACADE MOUNTING SYSTEMS APPLICATIONS

module - 57.5 mm
module - 57.5 mm

UP-L, UP or UP-S

height of module field = (length of module insertion + 115 mm) * number of modules + 69 mm

UP-L, UP or UP-S

145

module - 57.5 mm

length of module
lenght of module

(length od module + 20) * number of modules - 20 (en mm)

1. TRI-STAND vertical installation

POTENTIAL APPLICATIONS
on facades by means of hanger bolts
directly on facades by means of dowels or wood screws
ADVANTAGES
Module installation
Insertion system: optimum load distribution and time-saving no-screw installation
Clip system: materials-saving mode of installation and low system costs per kWp
Facade installation
low module load (only wind pressure and suction)
no plastering of facades necessary
developing new areas for PV systems
freely selectable degree of ventilation
Quality
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
UP-C universal profile
UP-TS profile
TS edging tool

the basic profile


profile for high static loads
material-optimized profile
secure connection of profiles with insertion system
for SafeClick installation directly on building exterior
for edge-trimming the profiles

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

MOUNTING SYSTEMS APPLICATIONS V. FACADE

2. TRI-STAND inclined installation


anchoring forces
AH, AV, BH and BV

anchoring forces
AH, AV, BH and BV

ule

69

75

ule

od

length of an individual wall rail

.5

11

module inclincation

module inclincation

-5

od

length of an individual wall rail

-S

,U

or

UP

-L

UP

UP profile

clearance for individual wall rails

row spacing

-S

,U

or

UP

-L

UP

length of an individual wall rail

UP

UP-S profile

-L

UP

or

length of horizontal support

UP-S profile

-S

UP

length of an individual wall rail

vertical row spacing

clearance for individual wall rails

ngle
ga
din
sha

146

ngle
ga
din
sha

length of horizontal support

UP profile

UP profile

POTENTIAL APPLICATIONS
PV systems with canopy roof function
ADVANTAGES
Module installation
on facades by means of hanger bolts
directly on facades by means of dowels or wood screws
Facade installation
developing new areas for PV systems
flexible angle of inclination (20 70)
Quality
components of high-quality aluminium and V2A stainless steel
5-year guarantee, with training extendable to 10 years
TRI-DESIGN software for optimum, standard planning and dimensioning of the system
(insertion system)
MOST IMPORTANT COMPONENTS

UP universal profile
UP-S universal profile
UP-L universal profile
TS profile
FlexFix angle
SafeClick
TS edging tool

the basic profile


profile for high static loads, required depending on dimensioning
material-optimized profile
insertion profile
freely selectable angle between 20 and 70
secure profile connection
for edge-trimming the profiles when using insertion system

147

TRITEC Group www.tritec-energy.com | 20130923-2 | Subject to technical changes

Accessories
Our accessories include exible cables particularly suited
for solar systems. The cables are extremely robust,
mechanically resistant, free of halogen as well as UV- and
weather-resistant. In addition, our range of accessories
includes any item needed for the assembly and
maintenance of solar systems.

HUBER+SUHNER
STUDER
MULTI-CONTACT
AMPHENOL
NINGBO
SMK
TYCO
RENNSTEIG
PHOENIX CONTACT

149

...................................................................................................................................................................
ACCESSORIES

Solar Cable

...................................................................................................................................................................

Radox solar cables UV-resistant, halogen-free


and extremely rugged
Radox solar cables are exible single-core and multicore cables specically suitable for the wiring of solar
installations both inside buildings and outside.

Long service life

150

The cables are extremely rugged, feature an extremely


high mechanical resistance and are extremely resistant
to heat, low temperature, oil, abrasion, UV, ozone and
weathering. These properties guarantee a long service
life. All these properties are achieved with small outside diameters thanks to Radox technology and high
precision.

Absolutely no shrinkage

material displays absolutely no shrinkage and absolutely no other changes over time. This is of advantage
particularly for coating and potting and for tting
connectors. Even at high temperatures, the electron
beam-crosslinked material does not melt or ow.
Nevertheless, the insulation can be stripped easily
from the cables.
The fact that the material contains no halogens means
that no corrosive or toxic gases are produced and little
smoke is generated in the event of a re. The cable
insulation is ame-retardant and can consequently not
catch re of its own accord.

The cables are easy to process owing to the close manufacturing tolerances. The electron beam-crosslinked

Radox solar cables used successfully worldwide for many


years now. Operating temperature range -40 to +120C,
short-circuit-resistant up to temperatures of +280C.

Radox single-core solar cable


1) Conductor: Tinned exible copper lead, ne-wire
2) Insulation: Radox black
3) Jacket: Radox, colours see technical data

...................................................................................................................................................................
Solar Cable

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302175

1302178

1302176

1302179

1302177

Model

Radox solar cable 4 rd,


100 m drum
4.0 mm
Red
5.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +120 C
+280 C (max. 5 seconds)

Radox solar cable 4 rd,


500 m drum
4.0 mm
Red
5.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +120 C
+280 C (max. 5 seconds)

Radox solar cable 4 bu,


100 m drum
4.0 mm
Blue
5.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +120 C
+280 C (max. 5 seconds)

Radox solar cable 4 bu,


500 m drum
4.0 mm
Blue
5.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +120 C
+280 C (max. 5 seconds)

Radox solar cable 4 bk,


100 m drum
4.0 mm
Black
5.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +120 C
+280 C (max. 5 seconds)

Insulation
Weight *
Warranty
Norms

Tinned exible copper


lead, ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV
type approved
certicate no. R
02210086

Tinned exible copper


lead, ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV
type approved
certicate no. R
02210086

Tinned exible copper


lead, ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV
type approved
certicate no. R
02210086

Tinned exible copper


lead, ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV
type approved
certicate no. R
02210086

Tinned exible copper


lead, ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV
type approved
certicate no. R
02210086

Art. No.

1302180

Model

Radox solar cable 4 bk, 500 m Radox solar cable 6 rd, 100 m Radox solar cable 6 rd, 500 m Radox solar cable 6 bu, 100 m
drum
drum
drum
drum
4.0 mm
6.0 mm
6.0 mm
6.0 mm
Black
Red
Red
Blue
5.8 mm 0.15 mm
6.9 mm 0.20 mm
6.9 mm 0.20 mm
6.9 mm 0.20 mm
1000 V DC
1000 V DC
1000 V DC
1000 V DC
4 x diameter
4 x diameter
4 x diameter
4 x diameter
-40 to +120 C
-40 to +120 C
-40 to +120 C
-40 to +120 C
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)

Cross section
Colour
Cable diameter
Rated voltage
Min. bending radius
Temperature range
Short-circuit-resistant up to
temperature of
Conductor

Cross section
Colour
Cable diameter
Rated voltage
Min. bending radius
Temperature range
Short-circuit-resistant up to
temperature of
Conductor

1302181

1302184

1302182

Insulation
Weight *
Warranty
Norms

Tinned exible copper lead,


ne-wire
Radox black
6.6 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Art. No.

1302185

1302183

1302186

1301323

Model

Radox solar cable 6 bu, 500 m Radox solar cable 6 bk, 100 m Radox solar cable 6 bk, 500 m Radox solar cable 10 bk
drum
drum
drum
6.0 mm
6.0 mm
6.0 mm
10.0 mm
Blue
Black
Black
Black
6.9 mm 0.20 mm
6.9 mm 0.20 mm
6.9 mm 0.20 mm
8.1 mm 0.15 mm
1000 V DC
1000 V DC
1000 V DC
1000 V DC
4 x diameter
4 x diameter
4 x diameter
6 x diameter
-40 to +120 C
-40 to +120 C
-40 to +120 C
-40 to +120 C
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)
+280 C (max. 5 seconds)

Cross section
Colour
Cable diameter
Rated voltage
Min. bending radius
Temperature range
Short-circuit-resistant up to
temperature of
Conductor
Insulation
Weight *
Warranty
Norms

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
9.2 kg
15 years
IEC 60228, class 5, TV type
approved certicate no. R
02210086

Tinned exible copper lead,


ne-wire
Radox black
14.4 kg
15 years
IEC 60228, class 5

* - Nominal kg/100 m

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

151

...................................................................................................................................................................
ACCESSORIES

Solar Cable

...................................................................................................................................................................

Studer Betaam Solar


Innovative solar cables
Leoni Studer AG Internationally proven

With more than 34,000 employees in over 100 locations


in 30 countries, the company is one of the leading
manufacturers of cables, conduits and grid systems.
The business unit "Wind and Solar Power" contributes
to a high-quality broad cable range for the sectors
industry, infrastructure and energy. It produces cables
and for these develops and processes superior compounds for conductor insulation. Leoni Studer AG is
part of the internationally active Leoni Group and
represents highest quality and innovative technology.

and can unreservedly be used as module and connecting cables for stand-alone and grid-connected systems.

Safe design
n
n

Advantages in brief
n

152

Best features

Long life-cycle and optimum weather resistance with


these features, Leoni Studer solar cables meet all requirements made of solar systems and their components. The double-insulated, electron beam crosslinked cables meet the highest standards of solar cables

The double insulated electron beam cross-linked solar cables


of Studer are suitable for grid-connected and stand-alone
systems.

Conductor: Braided copper wire, tinned, ne, class 5


Insulation: Polyolen Copolymer electron beam
cross-linked
Jacket: Polyolen Copolymer electron beam crosslinked

n
n
n
n
n
n

UV and ozone resistant


Hydrolysis resistant
Electron beam cross-linked compounds
High temperature resistance
Cold exibility
Long life-cycle
Compatible with all major connectors

The Studer solar cables are UV and ozone resistant and


suited for a temperature range of -40 up to +85C.

...................................................................................................................................................................
Solar Cable

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302197

1302203

1302198

1302204

Model

Studer Betaam 125 ex,


4 mm bk, 500 m drum
4.0 mm
Black
5.9 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +85 C
+280 C

Studer Betaam 125 ex,


4 mm bk, 100 m drum
4.0 mm
Black
5.9 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +85 C
+280 C

Studer Betaam 125 ex,


6 mm bk, 500 m drum
6.0 mm
Black
6.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +85 C
+280 C

Studer Betaam 125 ex,


6 mm bk, 100 m drum
6.0 mm
Black
6.8 mm 0.15 mm
1000 V DC
4 x diameter
-40 to +85 C
+280 C

Tinned exible copper lead,


ne-wire
Polyolen Copolymer electron
beam cross-linked
7.0 kg
2 years
IEC 60332-1, IEC 61034, EN
50268-2, DIN 51900, TV PfG
1169/08.2007 PV1-F

Tinned exible copper lead,


ne-wire
Polyolen Copolymer electron
beam cross-linked
7.0 kg
2 years
IEC 60332-1, IEC 61034, EN
50268-2, DIN 51900, TV PfG
1169/08.2007 PV1-F

Tinned exible copper lead,


ne-wire
Polyolen Copolymer electron
beam cross-linked
9.7 kg
2 years
IEC 60332-1, IEC 61034, EN
50268-2, DIN 51900, TV PfG
1169/08.2007 PV1-F

Tinned exible copper lead,


ne-wire
Polyolen Copolymer electron
beam cross-linked
9.7 kg
2 years
IEC 60332-1, IEC 61034, EN
50268-2, DIN 51900, TV PfG
1169/08.2007 PV1-F

Cross section
Colour
Cable diameter
Rated voltage
Min. bending radius
Temperature range
Short-circuit-resistant up to
temperature of
Conductor
Insulation
Weight *
Warranty
Norms

* - Nominal kg/100 m

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

153

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

Multi-Contact MC3 and MC4 connector systems


Multi-Contact AG was founded in 1962 and is currently
employing more than 700 staff. All manufacturing sites
are ISO 9001-certied and therefore meet the highest
quality demands.

n
n
n
n
n

MC connector systems

154

The components of the MC connector system for photovoltaics are designed to allow time-saving and safe
serial and parallel wiring of PV modules for buildingintegrated and free-standing solar installations. For
practical use the connector systems MC3 and MC4 are
available, depending on the existing modules or inverters.

The interlockable MC4 connector systems


n
n
n
n
n
n
n

The proven MC3 connector systems

Diameter 3 mm
Rated current
max. 30 A for 6 mm
max. 20 A for < 4 mm

The MC3 plugs and sockets, shown with associated contacts.

System voltage max. 1000 V


Degree of protection, connected IP65
Protection class II
Temperature range 40C to +90C
TV Rheinland type approved

Diameter 4 mm
Rated current max. 30 A
System voltage max. 1000 V
Degree of protection, connected IP67
Easy installation
Locking system "Snap in"
Protection class II
Temperature range 40C to +90C
TV Rheinland type approved

The MC4 plugs and sockets, shown with associated contacts.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302000

1302010

1302050

1302040

1302020

Model

Warranty

MultiContact PV-KBT3II
(A: 2 - 4 mm, D: 4.9 7.1 mm)
Female type MC3 for
Radox / Draka / Studer
4 mm
2 years

MultiContact PV-KST3II
(A: 2 - 4 mm, D: 4.9 7.1 mm)
Male type MC3 for
Radox / Draka / Studer
4 mm
2 years

MultiContact PVKBT3/6III (A: 6 mm, D:


6.5 - 9 mm)
Female type MC3 for
Radox / Draka / Studer
6 mm
2 years

MultiContact PVKST3/6III (A: 6 mm, D:


6.5 - 9 mm)
Male type MC3 for
Radox / Draka / Studer
6 mm
2 years

MultiContact PVKBT4/6II (A: 4 - 6 mm,


D: 5.5 - 9 mm)
Female type MC4 for
Radox / Draka / Studer
4 - 6 mm
2 years

Art. No.

1302030

1302073

1302085

1302086

1302087

Model

MultiContact PV-R-WZ3 MultiContact PV-ESCZM-19100 crimping


pliers insert
Installation device for
For MC4 (only use with
male and female MC3 locator)

MultiContact PV-CZM16100A crimping pliers

MultiContact PV-LOC
crimping pliers locator

For MC3 (MC4: insert


and locator necessary)

For MC4 (only use with


crimping pliers insert)

Warranty

MultiContact PVKST4/6II (A: 4 - 6 mm,


D: 5.5 - 9 mm)
Male type MC4 for
Radox / Draka / Studer 4
- 6 mm
2 years

2 years

2 years

2 years

Art. No.

1302116

Model
Description

Description

Description

2 years
1302118

1302115

MultiContact PV-WZ-AD/GWD MultiContact PV-SSE-AD4

MultiContact PV-PST test pin

Socket wrench insert for


crimping pliers PV-CZM
2 years

For MC type 4

Warranty

Socket wrench insert for


crimping pliers PV-CZM
2 years

MultiContact assembly key PVMS


For MC type 4

2 years

2 years

Art. No.

1302152

1302153

1302154

1302155

Model

MultiContact PV branch plug


MC3 PV-AZS3-UR
For MC type 3
2 years

MultiContact PV branch
socket MC3 PV-AZB3-UR
For MC type 3
2 years

MultiContact PV branch plug


MC4 PV-AZS4
For MC type 4
2 years

MultiContact PV branch
socket MC4 PV-AZB4
For MC type 4
2 years

Description
Warranty

1302117

The MC3 plugs are based on contacts with a diameter of


3 mm and comply with protection class IP65.

The interlockable MC4 plugs have contacts with diameters


of 4 mm and comply with protection class IP67.

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

155

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

Huber+Suhner Radox Connector


The innovative connector system
Photovoltaic solar cables and connectors are essential
components of solar installations. They ensure the electric connection between the modules and the inverters. They play an important role for the high efciency
and long service life of the installations. The expected
long service life, adverse exterior environmental inuences and great uctuations of temperatures and
humidity make heavy demands on design, material
and manufacture.

Solar cables and connectors combined


156

Huber+Suhner solar cables and connectors are perfectly matched, have been specically designed for
use in PV installations and have delivered optimal performances for many years.

in this form without lamella contacts. As exible elements, these contacts form the mechanical adjustment
between plug and socket. The lamella produces a
larger contact surface between the elements, thus providing a higher current load capacity with lowest constant contact resistance. All Huber+Suhner solar connectors are compatible for interconnection with each
other.

Connector characteristics
n
n
n
n
n
n

Lamella contacts The core of the connectors


Huber+Suhner's Radox solar connectors consist of casing and contact element. The core of the connectors
are the lamella contacts made from high-quality copper beryllium. Comparable values cannot be achieved

The interlockable Radox connectors are compatible with 4


or 6 mm Radox cables.

n
n
n
n

Temperature range 40C to +110C


Max. current carrying capacity 38 A
Max. system voltage 1000 V
Constant low transition resistance
High mechanical resistance
UV- and ozone resistant
Protection mode IP67 in mated condition
Interlockable by means of threads
Protection class II
TV approval

High-quality lamella contacts on turned contact elements


with integrated thread lock ensure high functionality and
safety.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302143

1302144

1302145

1302146

Model

Huber+Suhner Radox male


4 mm
4 mm
Brass, tin-plated
Copper beryllium lamella
contact
Radox cable 4 mm
-40 to +110 C
38 A at +85 C
1000 V DC
< 4 m
Class II
IP67 in mated condition
2 years
DIN VDE 0126-3, TV-certied
R 60017637

Huber+Suhner Radox female


4 mm
4 mm
Brass, tin-plated
Copper beryllium lamella
contact
Radox cable 4 mm
-40 to +110 C
38 A at +85 C
1000 V DC
< 4 m
Class II
IP67 in mated condition
2 years
DIN VDE 0126-3, TV-certied
R 60017637

Huber+Suhner Radox male


6 mm
4 mm
Brass, tin-plated
Copper beryllium lamella
contact
Radox cable 6 mm
-40 to +110 C
38 A at +85 C
1000 V DC
< 4 m
Class II
IP67 in mated condition
2 years
DIN VDE 0126-3, TV-certied
R 60017637

Huber+Suhner Radox female


6 mm
4 mm
Brass, tin-plated
Copper beryllium lamella
contact
Radox cable 6 mm
-40 to +110 C
38 A at +85 C
1000 V DC
< 4 m
Class II
IP67 in mated condition
2 years
DIN VDE 0126-3, TV-certied
R 60017637

Connector diameter
Contact carrier
Contact principle
Connectable cross-section
Temperature range
Current carrying capacity
Max. system voltage
Contact resistance
Protection class
Protection mode
Warranty
Norms
Accessories
Art. No.

1302147

Model
Description

Rennsteig crimping insert to Huber+Suhner 4 - 6 mm


Crimping insert for crimping pliers PEW 12

157

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

The Amphenol H4 PV connectors


Amphenol

Amphenol is one of the largest manufacturers of interconnect products in the world. The company designs
and manufactures electrical, electronic and bre optic
connectors along with coaxial and at-ribbon cables.

Connectores H4

The H4 connectors come from the innovative range of


Amphenol's Helios solar products. Quick and easy snap
lock mating and reliable crimp terminations make this
an ideal solution for eld installation. The long-term

UV and ozone resistance as well as the low resistance


self-cleaning contact grid distinguish the H4 as the
most efcient and durable solar connector option.
The H4 is fully intermateable with industry standards.

Product properties
n
n
n
n

Quick and easy snap lock mating


UV and ozone resistance
Self-cleaning contact grid
Protection mode IP68

158

The H4 connectors ensure quick and easy eld installation.

The Amphenol installation wrench ensures easy installation


and release of the connectors.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302241

1302242

1302243

1302244

Model

Warranty

Amphenol H4 CFC4DC female (A: 4 mm)


For Radox / Draka / Studer
4 mm
2 years

Amphenol H4 CMC4DC male (A: 4 mm)


For Radox / Draka / Studer
4 mm
2 years

Amphenol H4 CFC6DC female (A: 6 mm)


For Radox / Draka / Studer
6 mm
2 years

Amphenol H4 CMC6DC male (A: 6 mm)


For Radox / Draka / Studer
6 mm
2 years

Accessories
Art. No.

1302245

1302239

Amphenol H4 TW00001 - installation


wrench
For Amphenol H4, female / male 4 6 mm
2 years

Rennsteig crimping insert to


Rennsteig locator to Amphenol H4
Amphenol H4
For Amphenol H4, female / male 4 6 mm For Amphenol H4, female / male 4 6 mm
2 years
2 years

Description

Model
Description
Warranty

1302240

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

159

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

The Ningbo PV connectors


As an experienced manufacturer of electrical components for renewable energy systems, Ningbo Zhonghuan Sunter PV Technology Co. Ltd. produces primarily
connectors for use in solar modules and systems. Due to
its own research and development; Ningbo has been
successful in offering high-quality connectors since
2004.

Use

Ningbo connectors have a great exibility of use due to


their simple installation and reliable connection. Their
compact construction and high-quality workmanship
enable the system to be used even in difcult areas.

Product properties
n

Connection

160

For installation and mounting, the Ningbo plug-in system can be connected simply, quickly and thus highly
efciently. The rm connection of plug and socket is
ensured at any time by means of mechanical interlocking.

The Ningbo connectors are usable for 4 and 6 mm solar


cables.

n
n
n
n

Quick installation
Mechanical interlocking
High reliability of connections
Sturdy housing
TV-certied

Professional installation is ensured with Rennsteig crimping


tools.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302246

1302247

Model
Description
Warranty

Ningbo (PV-ZH202) - female (A: 4 - 6 mm)


For Radox / Draka / Studer 4 - 6 mm
2 years

Ningbo (PV-ZH202) - male (A: 4 - 6 mm)


For Radox / Draka / Studer 4 - 6 mm
2 years

Accessories
Art. No.

1302251

Model
Description

Rennsteig locator to Ningbo


Locator for crimping pliers PEW 12

161

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

The SMK PV connectors


SMK

Since 1925, SMK Corporation has been developing,


producing and distributing electrical and electronic
components, switches and remote controls for medical
applications as well as for all areas in renewable energies. Because of their many years of experience and
permanent optimization of development and production processes, SMK offers proven and top-quality technology. In product development, the company's particular focus is on sustainability and environmental protection.

Best conductivity

The product characteristics of SMK PV connectors incorporate know-how and ndings from many years of
development and production of connectors for various
application areas. Using the proven SMK multi-point
structure, PV connectors will realize optimum contactability and conductivity.

Characteristics at a glance
n
n
n

162

High reliability

Thanks to their well-conceived type of design and the


materials used, SMK connectors are a reliable product
in all weather conditions. Without any additional tools,
the connectors can be closed waterproof and thus
ensure ease of installation and optimum reliability.

SMK connectors can be used for 4 and 6 mm solar cables.

n
n
n

Optimum plug-in security


High ampacity
TV and UL certied
Protection mode IP67
Mechanical interlocking
Solar cable with 4 and 6 mm can be used

Professional installation is ensured with Rennsteig crimping


tools.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302252

1302253

1302254

1302255

Model
Description
Warranty

SMK PV-03 female 4 mm


For Radox / Studer 4 mm
2 years

SMK PV-03 male 4 mm


For Radox / Studer 4 mm
2 years

SMK PV-03 female 6 mm


For Radox / Studer 6 mm
2 years

SMK PV-03 male 6 mm


For Radox / Studer 6 mm
2 years

Accessories
Art. No.

1302233

1302234

Model
Description

Rennsteig crimping insert to SMK


Crimping insert for crimping pliers PEW 12

Rennsteig locator to SMK


Locator for crimping pliers PEW 12

163

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

Tyco Solarlok The photovoltaic connector


system
With 60 years of industry expertise, Tyco Electronics is a
worldwide supplier of passive electric and electronic
components and one of the leading manufacturers of
wiring systems for photovoltaics.

nents, in order to signicantly reduce the installation


costs of the whole photovoltaic system.

The Solarlok connectors overview


n

Easy and reliable interconnection

164

By continuously improving and expanding the Solarlok


connector system, Tyco Electronics contributes to the
establishment of this environmentally friendly and
future-oriented technology on the energy market.
The Solarlok connector system represents the easy
and reliable interconnection of individual solar modules to the inverter.

n
n
n
n

n
n
n

Easy processing on-site


Secure connection due to keyed housing
Mechanical interlocking
Easy multiple plugging
Accommodates solar cables of different diameters
reliably
High current carrying capacity
High temperature stability
TV and UL certied

The Solarlok concept

The entire system concept is based on cost-effective


and reliable processing of individual system compo-

The Tyco Solarlok connectors in different versions for 4 and


6 mm solar cables.

With the Tyco Solarlok system the female and the male are
both available with Plus and Minus conguration.

...................................................................................................................................................................
Plugs and Sockets

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302102

1302103

1302104

1302105

Model

Tyco Solarlok male minus


4.0 mm
For Radox / Draka / Studer
4 mm

Tyco Solarlok female minus


4.0 mm
For Radox / Draka / Studer
4 mm

Tyco Solarlok male plus


4.0 mm
For Radox / Draka / Studer
4 mm

Tyco Solarlok female plus


4.0 mm
For Radox / Draka / Studer
4 mm

Art. No.

1302106

1302107

1302108

1302109

Model

Tyco Solarlok male minus


6.0 mm
For Radox / Draka / Studer
6 mm

Tyco Solarlok female minus


6.0 mm
For Radox / Draka / Studer
6 mm

Tyco Solarlok male plus


6.0 mm
For Radox / Draka / Studer
6 mm

Tyco Solarlok female plus


6.0 mm
For Radox / Draka / Studer
6 mm

Art. No.

1302166

1302167

1302168

1302169

Model

Tyco T-connector (male/male)


plus
Parallel connection of Tyco
Solarlok connectors

Tyco T-connector (male/male)


minus
Parallel connection of Tyco
Solarlok connectors

Tyco T-connector
(female/male) plus
Parallel connection of Tyco
Solarlok connectors

Tyco T-connector
(female/male) minus
Parallel connection of Tyco
Solarlok connectors

Description

Description

Description

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

165

...................................................................................................................................................................
ACCESSORIES

Plugs and Sockets

...................................................................................................................................................................

Accessories
Art. No.

1302110

1302111

1302112

1302113

1302114

Model

Tyco Solarlok manual


crimping pliers

Tyco Solarlok press-out


tool

Tyco Solarlok support


protection

Tyco Solarlok service


case

Description

Universal, without
crimphead

Tyco Solarlok
crimphead for 4 and
6 mm
Go with Tyco Solarlok
manual crimping pliers

For dismantling of
Solarlok male/female

For all solar cables with 100 cable coupler /


1.5 / 2.5 / 4.0 / 6.0 mm crimp contacts, incl.
tools

166

Tyco Solarlok connectors 4 mm

Tyco Solarlok connectors 6 mm

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

167

...................................................................................................................................................................
ACCESSORIES

Fitting Tool

...................................................................................................................................................................

Rennsteig Tools Solar Tools for Cutting,


Stripping and Crimping
Rennsteig Werkzeuge GmbH this company in the
community of Viernau/Thuringia (Germany) follows
a long tradition of hand tools development and manufacture in this region. Based on this experience the
Rennsteig Werkzeuge GmbH, since 1991 a subsidiary of
Knipex Werk, was founded.

Cable shears

168

The forged cable shears are universally deployable for


cutting, stripping and peeling of cables with diameters
of up to 50 mm. The sharp, hardened blades with
precision grinding ensure easy and clean cuts, using
only one hand. Crushing and distortion of cable conductors and insulation are avoided.

Insulation stripping pliers

These special pliers with length stop are perfect for


high-quality and damage-free stripping and peeling.
During stripping the cable is not crushed or distorted.
The exchangeable knives allow working with cables of
diameters of 1.5 6 mm as standard. The compact

The Rennsteig Pro Kit contains cable shears, stripping pliers


and crimping pliers (one of each), suitable for MC3, MC4,
Ningbo and Tyco.

design and good handling of these pliers rest on the


ergonomical design of the two-component handles.

Crimping system pliers

The crimping pliers PEW 12 are recommended for


crimping of solar contacts of almost all connector systems. Crimping can ensure the exact electrical connection without soldering. The excellent handling, easy
exchange of the crimping insert bits and the possibility
of adding a positioning aid are facts in favour of these
crimping pliers.

Solar Kits

The practical plastic case of the Pro Kit contains cable


shears, stripping pliers and crimping pliers (one of
each). Thus the Pro Kit enables almost all jobs associated with cables and connectors. As standard, the
Pro Kit is equipped with crimping insert bits and
locators (positioning aids) for MC3, MC4, Ningbo and
Tyco. Additional insert bits are available as options. In
addition, the Universal Kit contains installation tools
for MC3 and MC4.

The Rennsteig crimping pliers PEW 12 are suited for various


connector systems, due to their different crimping insert
bits.

...................................................................................................................................................................
Fitting Tool

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302150

1302149

1302135

1302205

Model

Dimensions (L / W / H)
Weight
Warranty
Norms

Rennsteig cable shears D15


(1.5 - 50 mm)
Cable shears with cutting
width of up to 50 mm
170 mm / 110 mm / 20 mm
240 g
2 years
-

Rennsteig stripping pliers (1.5 6 mm)


Pliers for solar cables of 1.5 6 mm
200 mm / 110 mm / 20 mm
425 g
2 years
-

Rennsteig crimping pliers


PEW 12
Crimping pliers for various
insert bits
200 mm / 110 mm / 20 mm
620 g
2 years
DIN 60352-2, DIN 41641

Rennsteig assembly tool to


MC3
Installation of MC3 connectors
with 2.5 - 10 mm
335 mm / 95 mm / 33 mm
540 g
2 years
DIN 60352-2

Art. No.

1302206

1302142

1302207

Model

Rennsteig assembly key set to MC4

Description

Tightening / loosening of MC4 cable


screw joints

Rennsteig Pro Kit to MC3, MC4, Ningbo


and Tyco
Flexible case for everything to do with
solar cables

Dimensions (L / W / H)
Weight
Warranty
Norms

115 mm / 40 mm / 18 mm
40 g
2 years
DIN 60352-2

340 mm / 275 mm / 83 mm
1300 g
2 years
DIN 60352-2

Rennsteig Universal Kit to MC3, MC4,


Ningbo and Tyco
Flexible case for everything to do with
solar cables, incl. installation tools for
MC3 / MC4
350 mm / 310 mm / 110 mm
3500 g
2 years
DIN 60352-2

Accessories
Art. No.

1302136

1302137

1302138

1302139

1302251

Dimensions (L / W / H)
Weight
Warranty
Norms

Rennsteig crimping
insert to MC3
38 mm / 33 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to
MC3
39 mm / 39 mm / 29 mm
20 g
2 years
DIN 60352-2

Rennsteig crimping
insert to MC4 & Ningbo
32 mm / 32 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to
MC4
39 mm / 39 mm / 29 mm
20 g
2 years
DIN 60352-2

Rennsteig locator to
Ningbo
20 mm / 39 mm / 29 mm
70 g
2 years
DIN 60352-2

Art. No.

1302140

1302141

1302147

1302151

1302208

Model

Rennsteig crimping
insert to Tyco

Rennsteig locator to
Tyco

Rennsteig crimping
insert to Hirschmann
2.5 - 6 mm
32 mm / 32 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig crimping
insert to Yukita

Dimensions (L / W / H)
Weight
Warranty
Norms

Rennsteig crimping
insert to Huber+Suhner
4 - 6 mm
32 mm / 32 mm / 12 mm 39 mm / 39 mm / 29 mm 32 mm / 32 mm / 12 mm
50 g
20 g
50 g
2 years
2 years
2 years
DIN 60352-2
DIN 60352-2
DIN 60352-2

38 mm / 33 mm / 12 mm
50 g
2 years
DIN 60352-2

Art. No.

1302209

1302210

1302211

1302233

1302234

Model

Rennsteig locator to
Yukita
20 mm / 39 mm / 29 mm
70 g
2 years
DIN 60352-2

Rennsteig crimping
insert to Lumberg LC4
38 mm / 33 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to
Lumberg LC4
20 mm / 39 mm / 29 mm
70 g
2 years
DIN 60352-2

Rennsteig crimping
insert to SMK
32 mm / 32 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to
SMK
39 mm / 39 mm / 29 mm
20 g
2 years
DIN 60352-2

Description

Model

Dimensions (L / W / H)
Weight
Warranty
Norms

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

169

...................................................................................................................................................................
ACCESSORIES

Fitting Tool

...................................................................................................................................................................

Art. No.

1302237

1302238

1302239

1302240

Model

Rennsteig crimping insert to


TongLing TL4
38 mm / 33 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to TongLing


TL4
20 mm / 39 mm / 29 mm
70 g
2 years
DIN 60352-2

Rennsteig crimping insert to


Amphenol H4
38 mm / 33 mm / 12 mm
50 g
2 years
DIN 60352-2

Rennsteig locator to
Amphenol H4
20 mm / 39 mm / 29 mm
70 g
2 years
DIN 60352-2

Dimensions (L / W / H)
Weight
Warranty
Norms

170

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

171

...................................................................................................................................................................
ACCESSORIES

Lightning Protection

...................................................................................................................................................................

Phoenix Contact surge protection Lightning


protection concepts for PV systems
Surge protection devices

Surges, caused by lightning strikes or switching actions,


are frequently the cause of damages and failures in
electrical equipment. Inverter failures mean cost-intensive equipment damages. Yield losses and repair costs
are consequences, which can be prevented by surge
protection devices.

Protection circuit devices

172

Surge protection devices must be considered for all


circuits: On the DC side between L+, L- and the earth
potential, and on the AC side between the phases L1,
L2, L3, the neutral wire and the earth potential. In
addition, all other circuits (e.g. data and measuring
technology circuits), which are connected to the inverter, must be protected with suitable products.

Direct and indirect lightning protection

Direct (exterior) lightning protection must be implemented by observing the protection zones and galvanic separations by means of lightning rods for the
PV generator. For indirect (interior) lightning protection, several Phoenix Contact products are available,
which should be installed directly before the devices to
be protected (or at the lightning protection zone transitions).

Features of the PV SETS


n
n
n
n
n

The PV SET 1000DC is equipped with plug-in SunClix connectors and ideally suited for lightning and surge protection
of individual PV strings.

Surge protection for the DC side


Optional: Surge protection for the AC side
IP65 housing
Plug-in PV SET DC with SunClix
For one string as standard, optional multi-string
available
PE pins for a minimum of 6 mm connection to
potential equalisation

The PV SET 1000DC/AC can provide protection against


surges in PV strings and AC outputs of single-phase inverters.

...................................................................................................................................................................
Lightning Protection

ACCESSORIES

...................................................................................................................................................................

Art. No.

1302156

1302157

Model

Phoenix Contact VALMS 1000DC/2+V-FM

Surge protection

DC, 1 string

Max. DC open circuit voltage


Max. DC permanent voltage (LPE)
Rated voltage AC
Max. AC permanent voltage (LN / N-PE)
Max. pre-fuse AC
Rated current DC
Nominal lightning discharge
current (8/20) s (L-N / N-PE)
Max. lightning discharge
current (8/20) s
Lightning testing current
(10/350) s
Protection level (L-N / N-PE)
Response time (L-N / N-PE)
Cable connection (rigid /
exible)
Protection mode
Dimensions (L / W / H)

1000 V
1000 V

Phoenix Contact PV SET Phoenix Contact PV SET Phoenix Contact PV SET Phoenix Contact PV-SET
230AC/1P-RCBO
1000DC, PV string
1000DC/AC, PV string & 5ST/600DC
AC
DC, 1 string
AC and DC, 1 string
DC, max. 5 strings
AC, single-phased with
RCD and LS
1000 V
1000 V
600 V
1000 V
1000 V
600 V
-

335 / 260 V

230 V
250 V

80 A
15 kA

30 A
15 kA

125 A
80 A
15 kA

30 A
15 kA

16 A
20 kA

30 kA

30 kA

30 kA

40 kA

40 kA

< 5 kV
< 25 ns
0.5 - 35 mm / 0.5 25 mm
IP20
65.5 mm / 52.5 mm /
90 mm
367 g
2 years
IEC protection class II,
EN-Type T2

< 5 / - kV
< 25 ns
SunClix

< 5 / 1.5 kV
< 25 ns
0.5 - 35 mm / 0.5 25 mm
IP65
254 mm / 180.0 mm /
123 mm
1523 g
2 years
IEC protection class II,
EN-Type T2

< 3.6 kV
< 25 ns
0.5 - 35 mm / 0.5 25 mm
IP65
300 mm / 300.0 mm /
142 mm
3410 g
2 years
IEC protection class II,
EN-Type T2

< 1.5 kV
< 25 / < 100 ns
2.5 - 35 mm / 2.5 35 mm
IP65
122 mm / 200.0 mm /
125 mm
1100 g
2 years
IEC protection class II,
EN-Type T2

Weight
Warranty
Norms

IP65
125 mm / 200.0 mm /
122 mm
1217 g
2 years
IEC protection class II,
EN-Type T2

1302158

1302159

1302214

Art. No.

1302215

1302216

1302160

1302161

Model

Phoenix Contact PV-SET


600DC/32A-SC
DC, 2 strings, SunClix
600 V
600 V

Phoenix Contact PV-SET


1000DC/13A-SC
DC, 2 strings, SunClix
1000 V
1000 V

Phoenix Contact FLT-CP-PLUS3S-350, AC 3~, type 1


AC
-

Phoenix Contact VAL-CP-3S350, AC 3~, type 2


AC
-

240 V
350 / 350 V

240 V
350 / 264 V

25 A
10 kA

9A
10 kA

315 A
25 / 100 kA

125 A
60 / 20 kA

40 kA

120 / 40 kA

Surge protection
Max. DC open circuit voltage
Max. DC permanent voltage (LPE)
Rated voltage AC
Max. AC permanent voltage (LN / N-PE)
Max. pre-fuse AC
Rated current DC
Nominal lightning discharge
current (8/20) s (L-N / N-PE)
Max. lightning discharge
current (8/20) s
Lightning testing current
(10/350) s
Protection level (L-N / N-PE)
Response time (L-N / N-PE)
Cable connection (rigid /
exible)
Protection mode
Dimensions (L / W / H)
Weight
Warranty
Norms

100 kA

< 3.1 kV
< 25 ns
2.5 - 6 mm / 2.5 - 6 mm

< 4.48 kV
< 25 ns
2.5 - 6 mm / 2.5 - 6 mm

< 1.5 kV
< 100 / 100 ns
2.5 - 35 mm / 2.5 - 25 mm

< 1.4 / 1.5 kV


< 25 / 100 ns
2.5 - 25 mm / 2.5 - 16 mm

IP65
122 mm / 200.0 mm / 200 mm
1700 g
2 years
IEC protection class II, EN-Type
T2

IP65
112 mm / 200.0 mm / 200 mm
1700 g
2 years
IEC protection class II, EN-Type
T2

IP20
- / 142.8 mm / 1748 g
2 years
IEC protection class I, EN-Type
T1, IEC 61643-1 / EN 61643-11

IP20
- / 49.2 mm / 416 g
2 years
IEC protection class II, EN-Type
T2, IEC 61643-1 / EN 61643-11

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

173

...................................................................................................................................................................
ACCESSORIES

Lightning Protection

...................................................................................................................................................................

174

Art. No.

1302162

1302163

1302164

1302165

Model

Phoenix Contact VAL-CP-1S350, AC 1~, type 2


AC
-

Phoenix Contact DT-LANCAT.6+, Ethernet


Ethernet data circuit
3.3 V

Phoenix Contact DT-TELERJ45, Analogue & ISDN


Analogue & ISDN data circuit
185 V

Phoenix Contact Plugtrab PT,


sensor system
Sensor system
12.8 V

240 V
350 / 264 V

130 V

9V

125 A
20 / 20 kA

1.5 A
0.1 / 2 kA

0.38 A
5 / 5 kA

2A
0.69 / 10 kA

40 / 40 kA

10 kA

20 kA

Surge protection
Max. DC open circuit voltage
Max. DC permanent voltage (LPE)
Rated voltage AC
Max. AC permanent voltage (LN / N-PE)
Max. pre-fuse AC
Rated current DC
Nominal lightning discharge
current (8/20) s (L-N / N-PE)
Max. lightning discharge
current (8/20) s
Lightning testing current
(10/350) s
Protection level (L-N / N-PE)
Response time (L-N / N-PE)
Cable connection (rigid /
exible)
Protection mode
Dimensions (L / W / H)
Weight
Warranty
Norms

2.5 kA

< 1.4 / 1.5 kV


< 25 / 100 ns
2.5 - 25 mm / 2.5 - 16 mm

< 0.009 / 0.7 kV


< 1 / 100 ns
RJ45

< 0.25 / 0.25 kV


< 100 / 100 ns
RJ45, 0.14 - 1.5 mm

< 0.018 / 0.45 kV


< 1 / 100 ns
0.2 - 4 mm / 0.2 - 2.5 mm

IP20
- / 25.3 mm / 226 g
2 years
IEC protection class II, EN-Type
T2, IEC 61643-1 / EN 61643-11

IP20
102 mm / 25.0 mm / 65 mm
329 g
2 years
IEC protection class / EN-Type
B2, C2, D1, IEC 61643-21 / EN
50173-1

IP20
102 mm / 25.0 mm / 65 mm
333 g
2 years
IEC protection class / EN-Type
B2, C2, C3, D1, IEC 61643-21

IP20
- / 17.5 mm / 653 g
2 years
IEC protection class / EN-Type
C1, C2, C3, D1, IEC 61643-21

The PV SET 5ST/600DC is suited for up to 5 strings with a


maximum voltage of 600 V DC each, which can be
connected directly by means of terminals.

1. Phoenix Contact VAL-MS 1000DC/2+V-FM


2. Phoenix Contact PV SET 1000DC, PV string
3. Phoenix Contact PV SET 1000DC/AC, PV string & AC
4. Phoenix Contact PV SET 5ST/600DC
5. Phoenix Contact FLT-CP-PLUS-3S-350, AC 3~, type 1
6. Phoenix Contact VAL-CP-3S-350, AC 3~, type 2
7. Phoenix Contact VAL-CP-1S-350, AC 1~, type 2
8. Phoenix Contact DT-LAN-CAT.6+, Ethernet
9. Phoenix Contact DT-TELE-RJ45, Analogue & ISDN
10. Phoenix Contact Plugtrab PT, sensor system

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

175

Storage Systems
Storage systems enable efcient storage of generated
solar power. Economical own consumption is thus
provided at any time of day or night, and independence
from the public grid will be increased. In an AC storage
system, the solar store is separately connected with
batteries to the local home network system in which the
inverter of the PV system is installed. In contrast, in the DC
system, PV modules are directly connected with batteries
to the solar store.

SMA
KACO
BOSCH
KOSTAL

177

...................................................................................................................................................................
STORAGE SYSTEMS

AC System

...................................................................................................................................................................

SMA Sunny Island Maximum own consumption


Storage system

Due to the Sunny Island system, solar energy will


always be available when needed even after sundown or if the sun is hidden behind a cloud cover. By
means of its battery management, the system automatically charges and discharges the connected battery. Only if the battery is fully charged and no household consumer needs power will the PV inverter feed
generated power into the public grid.

Hoppecke batteries

Due to their high charge and discharge load, Hoppecke's sealed lead-gel batteries are optimally suitable
for solar power storage. Thanks to the gel technology,
OPzV tubular plate batteries have a cycle life of about
2500 cycles with a 50 % depth of discharge.

Advantages in brief
n
n

SMA Smart Home

178

Intelligent household energy management is very easy


with SMA Smart Home: It combines PV system, consumers and solar store and completely automatically
controls all energy ows. Its central component is the
Sunny Home Manager. It bundles all generation and
consumption data, analyses them and clearly displays
the most important values.

The Sunny Island system is characterised by a particularly


high degree of efciency.

n
n

Power supply through own solar energy


High degree of independence from the public grid
will be possible
Intelligent load and energy management for higher
own consumption rates and more independence
Suitable for retrotting of existing systems or for
new systems
Feeding excess electric power into the public grid
Maintenance-free batteries

Generated solar energy is efciently buffer-stored in extremely deep cycle Hoppecke batteries.

...................................................................................................................................................................
AC System

STORAGE SYSTEMS

...................................................................................................................................................................

Art. No.

0600373

Model
AC nominal power
AC output 25 C (30 min /
5 min / 3 s)
Number of phases
Output voltage
Line voltage
Frequency
AC output current
Max. AC output current (peak)
Harmonic distortion (output
voltage)
Power factor at nominal
power
AC input voltage
Input frequency
Max. AC input current
Max. AC input power
DC input voltage batteries
Max. battery charging current
Nominal DC charging current
battery
Battery type
Battery capacity
Charge control
Max. efciency
Power consumption (without
load / standby)
AC short circuiting /
AC overload
DC reverse polarity protection /
DC fuse
Excess temperature /
Exhaustive battery discharge
Overvoltage category
Capable of emergency power
Operating temperature
Protection mode
Multi-function relay
Paraller connection
Battery temperature sensor
Data communication
Display
Dimensions (W / H / D)
Weight
Warranty *
Norms

Sunny Island 6.0H


4600 W
6000 W / 6800 W / 11000 W
1
Sine wave
230 V (202 V 253 V)
50 Hz (45 Hz 65 Hz)
20 A
120 A
<4%
-1 to +1
230 V (172.5 V 264.5 V)
50 Hz (40 Hz 70 Hz)
50 A
11500 W
48 V (41 V 63 V)
110 A
100 A

179

FLA, VRLA
100 Ah 10000 Ah
IUoU charging process with automatic full and equalising charge
95 %
< 26 W / < 4 W
Yes / Yes
No / No
Yes / Yes
III
Yes
-25 to +60 C
IP54
2
Yes
Yes
Yes
Externally via SRC-20
467 mm / 612 mm / 242 mm
63 kg
5 years
EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007, EN 61000-6-4:2007, EN 61000-3-12:2005, EN 55022:2006 + A1:2007,
EN 50178:1997, EN 62109-1:2010, protection class I, climatic category 3K6

* - Can optionally be extended to 10 / 15 / 20 / 25 years

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

...................................................................................................................................................................
STORAGE SYSTEMS

AC System

...................................................................................................................................................................

Hoppecke batteries
Art. No.

0303083

0303084

0303085

Hoppecke sun.power pack 4.9 kWh


SMA SI 6.0H
4.9 kWh
48 V
103 Ah
12 V 2 OPzV sun.power 120
4 pc.
2500 (approx.)

Hoppecke sun.power pack 7.4 kWh


SMA SI 6.0H
7.4 kWh
48 V
154 Ah
12 V 2 OPzV sun.power 180
4 pc.
2500 (approx.)

Hoppecke sun.power pack 9.8 kWh


SMA SI 6.0H
9.8 kWh
48 V
205 Ah
6 V 2 OPzV sun.power 250
8 pc.
2500 (approx.)

Dimensions (W / H / D)
Weight
Warranty

4 x 12 V 2 OPzV sun.power 120,


installation rack, battery connection
lines, Hoppecke battery fuse in ISO
housing and fuse links
890 mm / 870 mm / 260 mm
275 kg
2 years

4 x 12 V 2 OPzV sun.power 180,


installation rack, battery connection
lines, Hoppecke battery fuse in ISO
housing and fuse links
890 mm / 870 mm / 260 mm
370 kg
2 years

8 x 6 V 2 OPzV sun.power 250, 2 x


installation rack with 4 batteries each,
battery connection lines, Hoppecke
battery fuse in ISO housing and fuse links
2 x 660 mm / 870 mm / 260 mm
495 kg
2 years

Accessories
Art. No.
0201590

Model
SMA Sunny Home Manager

0600375
0600378

SMA SRC20 Remote Control


SMA SI Speedwire data module

Model
Storage capacity of batteries
System voltage
Battery capacity (C10)
Battery
Number of batteries
Number of cycles (at 20 C,
50 % DoD)
Included in delivery

180

Description
Energy management incl.
monitoring
Remote control
Speedwire data module

Belongs to Art. No.


0600373
0600373
0600373

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

181

...................................................................................................................................................................
STORAGE SYSTEMS

AC System

...................................................................................................................................................................

Kaco Powador-gridsave eco The intelligent


energy storage manager

182

Modular and exible

As an intelligent energy storage management system,


the Kaco Powador-gridsave eco is modular and exible
and can be used both for existing and new installations. Thanks to its efcient control technology, it
mediates between inverter, solar system, battery and
public power grid and thus enables the optimum efciency of the entire system. It thus realizes the highest
possible own consumption of own generated energy.

one unit, it combines an energy management system


for regulating the feed-in performance and for communicating with the inverter, the load management,
the bi-directional inverters with a battery loading management and monitoring, as well as the mains isolation
facility for separating the system from the public
power grid. The monitoring software included in the
scope of supply provides convenient and simple access
to the system and all parameters.

Emergency power supply

Advantages in brief

In case of interruption or failure of the public grid, the


Powador-gridsave eco presents the basis for a reliable
emergency power supply. Virtually uninterrupted, it
switches from the operating condition of its own consumption optimisation to emergency power operation
and thus allows the use of energy stored in the connected batteries.

Home energy management

n
n
n

Modular and exible application due to variable


battery capacity
Optimum supplement for existing solar systems by
AC coupling
Very high peak performances
Convenient visualization via PC access
Grid monitoring with changeover to emergency
power mode operation in case of grid failure

The Kaco Powador-gridsave eco provides the optimum


solution in the area of home energy management. In

The Kaco Powador-gridsave eco provides the optimum solution for around-the-clock supply with environmentally
friendly and safe solar power.

The intelligent energy storage manager allows efcient regulation of feed-in performance and communication with
the inverter.

...................................................................................................................................................................
AC System

STORAGE SYSTEMS

...................................................................................................................................................................

Art. No.

1700005

Model
Recommended max. output of
the AC-coupled inverter
AC nominal power
AC peak output (< 30 s)
AC rated voltage
AC rated current
Nominal frequency
Number of phases
Harmonic distortion
Capable of emergency power
Max. current grid switchover
Changeover time grid
switchover
DC battery voltage (nominal)
DC input voltage PV
DC rated current (25 C)
Battery
Number of batteries
Storage capacity of batteries
(C100)
Max. efciency
Protection mode
Display
Data communication
Included in delivery

Kaco Powador-gridsave eco package - 9.6 kWh


10 kW

Compatible inverters *
Dimensions (W / H / D)
Weight
Warranty
Norms

5 kW
12 kW
230 V
22 A
50 / 60 Hz
1
<3%
Yes
32 A
< 30 ms
48 V
40 - 68 V
104 A
Hoppecke 12 V 3OPzV bloc 200
4 pc.
9.6 kWh
96 %
IP43
LED
RS485, RS232, Ethernet via external interface converter, USB
Powador-gridsave eco - INT, 4 x 12 V 3OPzV bloc solar.power (total capacity 200 Ah), battery rack, connection set battery safety
unit and installation set with external 3-phase measuring point, Powador protect, 2 external coupling relays, power switch and
RCD
Kaco Powador series 00 and 02
375 mm / 690 mm / 220 mm
40 kg
2 years
IEC 62040-1-1:2002, EN 61000-6-3:2007, VDE-AR-N 4105 when using Powador protect

* - Not included in the scope of supply; for compatibility, update is possibly required

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

183

...................................................................................................................................................................
STORAGE SYSTEMS

DC System

...................................................................................................................................................................

Bosch BPT-S 5 Hybrid Solar inverter with


integrated battery
Storage system from Bosch

The BPT-S 5 Hybrid enables the exible use of solar


power in terms of time because unused volumes can be
stored. In addition to feeding solar power with optimum efciency into the public power grid, the hybrid
allows the improvement of own consumption and
bridging over grid power failures.

Integrated energy management system

184

The BPT-S 5 Hybrid is the combination of a transformerless 5 kW inverter, a lithium ion battery with a capacity
ranging from 4.4 kWh up to 13.2 kWh and a management system with a colour touch display. As needed,
the energy produced by the PV system will be either
directly consumed in the household, stored in the battery, or directly supplied into the public power grid.

battery power which had been collected during the


day. This provides much greater independence from
the public power grid.

Intelligent system management

The system is equipped with a comprehensive monitoring system. It has a system management available
which controls and monitors the energy ows and
the function of components. The battery management
takes care of the optimum charge and discharge of the
lithium ion battery and thus ensures a long service life.

Advantages in brief
n

Optimization of own PV consumption

Due to the BPT-S 5 Hybrid energy storage, PV power


can be utilized with a time delay. It is accordingly
possible, without any problem, to use at night the

For individual power demand, the BPT-S 5 Hybrid is available


in ve storage sizes.

Integrated energy management system with 5 kW


nominal output and a capacity from 4.4 kWh up to
13.2 kWh
Grid feed-in with an efciency of 97.7 %
Powerful lithium ion batteries designed for a service
life of up to 20 years
Highly efcient DC coupling

All components are perfectly coordinated with each other


and together form a fully integrated system of a compact
format.

...................................................................................................................................................................
DC System

STORAGE SYSTEMS

...................................................................................................................................................................

Art. No.

1700007

1700008

1700009

1700010

1700011

Model
AC nominal power *
Number of phases
Output voltage
Line voltage
Frequency
Max. AC output current (peak)
Harmonic distortion (output
voltage)
Power factor at nominal
power
Recommended PV system
power
DC inputs PV
Independent MPP trackers
DC input voltage PV
MPP voltage range
Max. DC input current PV
Battery technology
Battery voltage nominal
Storage capacity of batteries
Max. depth of discharge (DOD)
Expected service life
Max. charge & discharge
power
Capable of emergency power

BPT-S 5 Hybrid 4.4 kWh


5000 W
1
Sine wave
230 V
50 Hz (47.5 - 51.5 Hz)
22 A
<3%

BPT-S 5 Hybrid 6.6 kWh


5000 W
1
Sine wave
230 V
50 Hz (47.5 - 51.5 Hz)
22 A
<3%

BPT-S 5 Hybrid 8.8 kWh


5000 W
1
Sine wave
230 V
50 Hz (47.5 - 51.5 Hz)
22 A
<3%

BPT-S 5 Hybrid 11.0 kWh


5000 W
1
Sine wave
230 V
50 Hz (47.5 - 51.5 Hz)
22 A
<3%

BPT-S 5 Hybrid 13.2 kWh


5000 W
1
Sine wave
230 V
50 Hz (47.5 - 51.5 Hz)
22 A
<3%

0.7 (leading) 0.7 (lagging)


5 kWp

0.7 (leading) 0.7 (lagging)


5 kWp

0.7 (leading) 0.7 (lagging)


5 kWp

0.7 (leading) 0.7 (lagging)


5 kWp

0.7 (leading) 0.7 (lagging)


5 kWp

1
1
240 - 940 V
275 - 750 V
19 A
Lithium ion
96 V
4.4 kWh
70 %
15 years
2.50 kW

1
1
240 - 940 V
275 - 750 V
19 A
Lithium ion
144 V
6.6 kWh
70 %
15 years
3.75 kW

1
1
240 - 940 V
275 - 750 V
19 A
Lithium ion
192 V
8.8 kWh
80 %
15 years
5.00 kW

1
1
240 - 940 V
275 - 750 V
19 A
Lithium ion
240 V
11.0 kWh
80 %
15 years
5.00 kW

1
1
240 - 940 V
275 - 750 V
19 A
Lithium ion
288 V
13.2 kWh
80 %
15 years
5.00 kW

Yes

Yes

Yes

5.00 kW

5.00 kW

5.00 kW

24 V DC / 0.5 A
1

24 V DC / 0.5 A
1

24 V DC / 0.5 A
1

-10 to +40 C
IP20
CAN, USB, RS485, LAN,
V-CAN
597 mm / 1693 mm /
706 mm
262.0 kg
5 years
Protection class I
according to IEC 62103;
grid monitoring VDE
0126-1-1, VDE-AR-N
4105, CEI-021; EMV EN
61000-6-2, EN 61000-63; grid reaction, IEC
61000-3-2/-3-12, IEC
61000-3-3/-3-11; system
EN 62109-1, EN 62040-1;
battery EN 61010-1,
VDE 0411-1, UN 38.3, CE
conformity, BG test
label

-10 to +40 C
IP20
CAN, USB, RS485, LAN,
V-CAN
597 mm / 1693 mm /
706 mm
280.5 kg
5 years
Protection class I
according to IEC 62103;
grid monitoring VDE
0126-1-1, VDE-AR-N
4105, CEI-021; EMV EN
61000-6-2, EN 61000-63; grid reaction, IEC
61000-3-2/-3-12, IEC
61000-3-3/-3-11; system
EN 62109-1, EN 62040-1;
battery EN 61010-1,
VDE 0411-1, UN 38.3, CE
conformity, BG test
label

-10 to +40 C
IP20
CAN, USB, RS485, LAN,
V-CAN
597 mm / 1693 mm /
706 mm
299.0 kg
5 years
Protection class I
according to IEC 62103;
grid monitoring VDE
0126-1-1, VDE-AR-N
4105, CEI-021; EMV EN
61000-6-2, EN 61000-63; grid reaction, IEC
61000-3-2/-3-12, IEC
61000-3-3/-3-11; system
EN 62109-1, EN 62040-1;
battery EN 61010-1,
VDE 0411-1, UN 38.3, CE
conformity, BG test
label

Limited, only in case of Limited, only in case of


available PV power
available PV power
3.75 kW
Max. output power emergency 2.50 kW
power operation
Emergency power relay
24 V DC / 0.5 A
24 V DC / 0.5 A
Number of phases feed-in
1
1
emergency power supply
Operating temperature
-10 to +40 C
-10 to +40 C
Protection mode
IP20
IP20
Data communication
CAN, USB, RS485, LAN, CAN, USB, RS485, LAN,
V-CAN
V-CAN
Dimensions (W / H / D)
597 mm / 1693 mm /
597 mm / 1693 mm /
706 mm
706 mm
Weight
222.0 kg
242.0 kg
Warranty **
5 years
5 years
Norms
Protection class I
Protection class I
according to IEC 62103; according to IEC 62103;
grid monitoring VDE
grid monitoring VDE
0126-1-1, VDE-AR-N
0126-1-1, VDE-AR-N
4105, CEI-021; EMV EN 4105, CEI-021; EMV EN
61000-6-2, EN 61000-6- 61000-6-2, EN 61000-63; grid reaction, IEC
3; grid reaction, IEC
61000-3-2/-3-12, IEC
61000-3-2/-3-12, IEC
61000-3-3/-3-11; system 61000-3-3/-3-11; system
EN 62109-1, EN 62040-1; EN 62109-1, EN 62040-1;
battery EN 61010-1,
battery EN 61010-1,
VDE 0411-1, UN 38.3, CE VDE 0411-1, UN 38.3, CE
conformity, BG test
conformity, BG test
label
label

* - For Germany: 4600 W


** - Can optionally be extended

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

185

...................................................................................................................................................................
STORAGE SYSTEMS

DC System

...................................................................................................................................................................

Kostal Piko BA The energy storage system for


numerous applications
Intelligent and powerful

The Kostal Piko BA energy storage system combines


the best inverter technology with an intelligent energy
management and a high-quality as well as powerful
battery system. Optimum coordination of all components and their high quality bring about a system
which achieves best efciencies and ensures many
years of efcient utilization.

Innovative inverter technology

186

With a module power between 4 and 11 kWp, the Piko


BA provides charge regulator and inverter in one housing. Controlled by an intelligent energy management
system, the Piko BA achieves a maximum efciency of
96.5 %. While feed-in is effected on a demand-oriented basis, the integrated CAN interface enables the
connection to the battery management system of the
external storage thus the system is optimally equipped for novel storage technologies. The overall Piko BA
package is rounded off by the integrated communications and monitoring package, as well as the two independent MPP trackers.

Energy for home consumption, for storage or for grid feedin very simple with the intelligent Piko BA system.

Energy storage at a high level

The Piko battery is the optimum energy storage for the


direct consumption of photovoltaic energy. High
energy yield, long life, small space requirement, as
well as a modular design for simple installation all
that results in a complete storage solution from one
source. Moreover, operating costs are saved thanks to
the system's maintenance-free battery technology.
Optimum storage and management of the generated
energy is ensured together with the integrated battery
management system.

Advantages in brief
n

n
n

High-quality individual components, optimally


adjusted to each other
Three-phase storage system
High efciency due to the energy management of
the Piko BA inverter and charge regulator
Energy storage with an integrated battery management system for high energy yields
Home consumption recording with the Piko BA sensor

Home consumption is recorded by analogue current measurement of the Piko BA sensor.

...................................................................................................................................................................
DC System

STORAGE SYSTEMS

...................................................................................................................................................................

Art. No.

1700001

Model
AC nominal power
Number of phases
Output voltage
Line voltage
Frequency
AC rated current
Short circuit current (peak)
Harmonic distortion (output
voltage)
Power factor at nominal
power
Recommended PV system
power
DC inputs
Independent MPP trackers
DC input voltage PV
MPP voltage range (onetracker operation / two-tracker
operation)
Max. DC input current PV
DC input voltage batteries
Max. battery charging current
Max. battery discharge current
Max. efciency
Capable of emergency power
Operating temperature
Protection mode
Electronic isolation unit
Data communication
Connection (input / output)
Dimensions (W / H / D)
Weight
Warranty *
Norms

Kostal Piko BA
10000 W
3
Sine wave
230 V (184 - 264.5 V)
50 Hz
14.5 A
20 A
<3%
0.9 - 1 - 0.9
4 - 11 kWp
2
2
180 - 950 V
180 - 850 V / 440 - 850 V
12 A
228 V (211 - 314 V)
12 A
12 A
96.5 %
Yes
-20 to +60 C
IP55
Integrated
RS485, 2 x Ethernet, S0, 4 x analogue inputs, CAN interface
MC4 / spring-loaded terminal strip
520 mm / 450 mm / 230 mm
33 kg
5 years
Protection class I according to IEC 62103, overvoltage category II according to IEC 60664-1 input side, overvoltage category III
according to IEC 60664-1 output side

* - Can optionally be extended to 10 / 20 years

Continued on next page

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

187

...................................................................................................................................................................
STORAGE SYSTEMS

DC System

...................................................................................................................................................................

Accessories
Art. No.

188

Model
Battery type
Battery technology
Number of cycles (50 % DoD)
Storage capacity of batteries
(C10)
Max. output power
Number of batteries
Rated voltage
Battery capacity (C100)
Ventilation
Operating temperature
Protection mode
Weight
Rated current primary
Rated current secondary
Burden
Accuracy class
Max. line diameter
Dimensions (W / H / D)
Norms

1700004

1700002

Kostal Piko Battery


Hoppecke 12 V OPzV blocsolar.power 70
Maintenance-free, cycle-optimized lead-gel battery
2500
11.6 kWh

Kostal Piko BA Sensor


-

2.7 kW (approx.)
19 pc. (each 12 V nominal voltage)
228 V
70 Ah
Inlet and outlet air vent with 154 cm cross-sectional area
+10 to +30 C
IP21
850 kg (approx.)
900 mm / 1584 mm / 388 mm
IEC 60896-21, IEC 61427

50 A
1A
1 VA
1
13.5 mm
105 mm / 90 mm / 54 mm
EN 60715

Photos Kostal

TRITEC Group www.tritec-energy.com | 20140828-1 | The content of this datasheet is subject to change without prior notice

189

Customer Support and


Services
Supported in every aspect: We not only plan and calculate
photovoltaic systems of all sizes, we also offer
photovoltaic insurance upon request. Our web site offers
you our product software, documentations and brochures.
In addition, we regularly provide training courses.

191

Product Software
You can find helpful downloadable working and planning
tools on our web site at www.tritec-energy.com/productsoftware or on the page for the respective product.

There is also a software version for our handy characteristics analyser TRI-KA for performance testing of installed
solar modules available for download on web site.

Using the dimensioning software TRI-DESIGN, our PV mounting systems TRI-STAND, TRI-FLAT, TRI-VENT and TRI-ROOF
can be dimensioned quickly and easily.

Using the TRI-KA software, the actual output of the solar


system can be compared with the target output and displayed visually. Due to the system configurator and the
protocol assistant, any size of PV systems can be controlled
and maintained. The system structure can conveniently be
prepared at the office using the TRI-KA software and then
saved to a SD card and transferred to the TRI-KA. The service technician in the field can then quickly and efficiently
test the system without the need of additional entries into
the characteristics analyser.

Essential benefits of TRI-DESIGN:


Quick and intuitive dimensioning of TRITEC mounting
systems with just a few clicks
Comprehensive solar module and inverter* database
Consideration of the respective roof features and the
used solar modules
Automatic creation of a bill of materials, which can be
exported, edited and sent

Find more information on TRI-KA training courses in your


area at www.tritec-energy.com/training!

Find more information on TRI-DESIGN training courses in


your area at www.tritec-energy.com/training!

193

The dimensioning software TRI-DESIGN allows the optimum adjustment of PV systems to the respective roof. Taking into consideration
the used modules and inverters, the best model of the mounting
system possible can be chosen.
TRITEC Services AG

TRI-DESIGN calculates and dimensions mounting systems according


to the directives of DIN 1055**. The two relevant directives are
DIN 1055-4** for wind loads and DIN 1055-5** for snow and ice loads
affecting the photovoltaic system and its substructure.
TRITEC Services AG

Dimensioning software TRI-DESIGN

Available in the fee-based license

**

European standard: EN 1991-1-3

Training Courses
We regularly offer product training courses and workshops. You will find the current training dates, subjects
and venues on our web site:
www.tritec-energy.com/training

Our special training offerings for 2014


Mounting systems TRI-STAND, TRI-FLAT, TRI-VENT and
TRI-ROOF in practice: an intensive training course with
guarantee benefits
Design the mounting systems TRI-STAND, TRI-FLAT,
TRI-VENT and TRI-ROOF quickly and safely: This intensive
training course teaches you all you need to know about
roofs, load effects and statics and gives you the opportunity to apply the gained knowledge in practice: with the
mounting systems TRI-STAND, TRI-FLAT, TRI-VENT and
TRI-ROOF and the dimensioning software TRI-DESIGN.

Characteristics analyser TRI-KA: Easy and quick output


checking of installed solar modules
Our characteristics analyser TRI-KA, the TRITEC product for
checking the output of installed solar modules, is precisely
tailored to todays and future requirements of PV installers.
By analysing the characteristics, the solar systems output
can be measured during the installation, handover or
maintenance of the system and compared with the target
output. Working with the characteristics measuring device
TRI-KA could not be more efficient: The device is extremely
easy to operate and extraordinarily flexible and versatile
thanks to its technical enhancements.
This training course informs you about all the typical output reducing factors of photovoltaic systems, characteristics
analysis and the measuring procedure with the characteristics analyser TRI-KA.

Extension of manufacturers guarantee: All installers,


who successfully attended a TRI-STAND, TRI-VENT and
TRI-ROOF intensive training course, will receive a guarantee extension for TRI-STAND, TRI-VENT and TRI-ROOF of an
additional 5 years to 10 years in total.

195

Product Documentations and Brochures


Our download section offers product documentations,
declarations of conformity, installation instructions and
guarantee terms for all our products. In addition to our
product catalogue, our company brochure is available.

Photovoltaics with a system. Customised solar systems.

Training Centre France, Montpellier

General Terms and Conditions by the TRITEC Group for Commerce

1 Scope
1. TRITECs supplies, services and offers shall be exclusively made on the basis of
the following Conditions of Sale and Delivery. The once agreed upon Conditions
of Sale and Delivery shall also be valid for all future business relations even if
they are not once again explicitly agreed upon. Any agreements which are made
between the customer and TRITEC for the purpose of the execution of this contract shall be recorded in writing.
2. These conditions shall be considered accepted at the latest upon the receipt
of goods or services. TRITECs silence to different provisions by the customer shall
not be considered as a consent to the customers conditions; their validity is
opposed. Any deviation from TRITECs Conditions of Sale and Delivery shall be
considered as a rejection of the order; any receipt of a delivery notwithstanding
even subject to reservations shall be considered as consent to TRITECs Conditions of Sale and Delivery.
3. Any agreements between the customer and TRITEC which supplement or
modify these General Terms and Conditions shall only be valid if they are agreed
upon in writing.

196

2 Offer and Contract Conclusion


1. TRITECs offers or, respectively, quotations shall be principally non-binding
and without engagement, unless explicitly otherwise agreed upon.
2. Decisive shall otherwise be the prices, plus appropriate statutory sales tax, as
indicated in TRITECs order confirmation. Additional deliveries and services shall
be separately invoiced.
3. Offers by TRITEC refer to the requirements known to us with regard to the
specified quantities at the time of tendering or the confirmation regarding material quality, dimensional tolerances and manufacturers conditions. Subsequent changes shall require our explicit consent and entitle us to change the
price accordingly. Data in our brochures such as photos, drawings and other
specifications are only approximately. Accordingly, they establish neither a
quality agreement nor any warranty and shall not be relevant for the contractual provision of the service and delivery item.
4. Drawings, illustrations, dimensions, weights or other performance data shall
only be binding if this is explicitly agreed upon in writing. Any illustrations,
drawings, calculations and other documents shall remain TRITEC property and
may not be transmitted to third parties without explicit consent. This shall also
apply for such written documents which are designated confidential.
5. The contract shall only become effective by TRITECs written order confirmation to the customer based on the customers order; this may also be done electronically (via email).
6. The contract shall be concluded with the proviso of correct and on-time delivery to TRITEC by TRITECs suppliers. This shall only apply in the event that TRITEC
is not responsible for the non-delivery, in particular, upon conclusion of a
congruent covering deal with the supplier. The customer shall be immediately
informed about the non-availability of performance. The quid pro quo shall be
immediately reimbursed.
7. Upon contract signature, the customer shall agree to use the products only for
the purpose of use intended by the manufacturer.
3 Prices and Terms of Payment
1. TRITEC shall principally deliver against prepayment. If no prepayment is requested, the payment claim shall become due and payable at the latest with
the provision of the delivery for the customer. Partial deliveries shall be paid
within the scope of the individual delivery. Payment dates shall be complied
with even if the delivery or acceptance of goods is delayed for reasons which
TRITEC is not responsible for. Payments may not be reduced or refused due to
complaints or unaccepted claims. Any discount deduction shall require a special
written agreement.
2. Unless otherwise agreed upon in the order confirmation, prices shall be valid
ex manufacturer or TRITEC warehouse, plus costs for packaging, insurance and
shipping; these costs shall be separately invoiced.
3. TRITEC shall be entitled to change prices correspondingly if cost reductions or
cost increases result, after contract conclusion, especially due to wage settlements or material price changes. This shall be substantiated to the customer
upon request.
4. Statutory regulations shall apply regarding the consequences of any default in
payment. Without prior notice of default, a penalty interest of 7 % effective as
of the payment due date shall be invoiced for receivables which are not paid as
agreed.
5. The customer shall only be entitled to offset rights if the customers counterclaims are recognized by declaratory judgment, uncontested, or have been acknowledged by us in writing. Moreover, the customer is entitled to exercise a
right of retention insofar as his/her counterclaim is based on the same contractual relationship.

4 Period of Delivery and Service


1. The written form shall be required for delivery periods or due dates which
may be agreed upon as binding or non-binding. TRITECs compliance with delivery and performance obligations shall require the prerequisite of the customers
on-time and proper performance of obligations. TRITEC shall be entitled at any
time to partial deliveries and partial services, unless the partial delivery or the
partial service is unsuitable for the customer.
2. Even in case of bindingly agreed upon time limits and due dates, TRITEC shall
not be responsible for delivery and performance delays due to force majeure
and due to events which make any delivery for TRITEC not only temporarily considerably impaired or impossible this includes, in particular, strike, lock-out,
official orders, etc., even if they occur at our suppliers or their subcontractors.
This shall entitle TRITEC to postpone delivery or, respectively, performance by
the period of impairment, plus a reasonable start-up period or to rescind the
contract wholly or in parts because of the part not yet performed.
3. If the obstruction takes more than three months, the customer shall be entitled to rescind the contract with regard to the not yet performed part after
having granted a reasonable extension of time. If the delivery or performance
period is extended or if TRITEC is released from its obligations, the customer may
not derive any damage claims therefrom. TRITEC can only rely on the indicated
circumstances if it notifies the customer within a reasonable period of time.
4. As far as TRITEC is responsible for the non-compliance with bindingly promised time limits and due dates or if it is in delay, the customer shall be entitled to
a compensation for the delay in the amount of one half percent for every completed week of delay; at maximum, however, to a total of up to five percent of
the deliveries and services affected by the delay. Any claims in excess thereof
shall be excluded, unless the delay is due to at least gross negligence by TRITEC.
5. If the customer is in delay of acceptance, TRITEC shall be entitled to demand
restitution of the damage incurred. Unless already transferred, the risk of accidental deterioration and accidental loss shall pass over to the customer upon the
onset of the delay in acceptance.
5 Passage of Risk
1. The risk shall pass to the customer as soon as the shipment has been handed
over to the person carrying out the transport or has left our warehouse for the
purpose of shipment. If shipment is delayed upon the customers request, the
risk shall pass to the customer with the ready-for-shipment note.
2. If personal delivery is not possible due to the absence of the customer or a customers representative, TRITECs agent shall leave the material. The customers
risk and duty of care shall begin with the point in time of delivery, even without
any personal delivery.
6 Warranty
1. TRITEC shall be notified in writing of objections and complaints regarding
deliveries and services within five days after receipt of the shipment, or for turnkey plants within five days after first commissioning. Warranty claims by the
customer shall require that customer has properly complied with legally due requirements of examination and giving notice of defects.
2. Insofar as there is a defect of the goods, TRITEC shall be entitled, at its option,
to post-performance in the form of a remedy of defects or delivery of new, nondefective goods. In case of a remedy of defects, TRITEC shall be obligated to bear
all expenditures required for the purpose of the remedy of defects, in particular
the costs of transport, infrastructure, work and material insofar as they do not
increase due to the fact that the goods were taken to another location than the
place of performance.
3. If post-performance fails, the customer shall be entitled to optionally demand
rescission or reduction.
4. If the customer receives deficient assembly instructions, TRITEC shall merely be
obligated to deliver faultless assembly instructions; this, however, only if the
deficiency in the assembly instructions conflicts with proper assembly.
5. The warranty period shall be one year as of delivery. For consumers, the period
of limitation shall be two years as of delivery. In case of an agreement of acceptance, the warranty period shall begin on the day of acceptance of the delivery
object. The above shall not apply if the customer had not notified the defect in
due time.
6. After expiry of the warranty period, TRITEC grants the performance warranty
for modules to the customer according to the manufacturer warranty provided,
as far as TRITEC can claim on the manufacturers performance warranty.
7. Guarantees in the legal sense shall only be given by TRITEC if they are explicitly included in the order confirmation and have been designated as a promise
of specific properties of the delivery object.
8. Warranty shall be excluded if the customer or a third party charged by the
customer has improperly performed work on the delivery object. Any warranty
claims shall expire if the customer attaches unauthorized additional devices or

either him/herself or through third parties provides unauthorized interventions


and/or repairs on delivery objects without explicit arrangement with TRITEC.
7 Liability
1. TRITEC shall be liable according to the statutory conditions as far as the customer claims damages which are based on intent or gross negligence, including
intent or gross negligence by our representatives or vicarious agents. As far as
TRITEC is not charged with any intentional or grossly negligent breach of contract, the liability for damages shall be limited to the foreseeable, typically
occurring damage or, respectively, excluded by agreement for countries in which
this is permitted.
2. However, liability for damages shall be limited in all of the cases to the foreseeable, typically occurring damage, unless such a limitation violates mandatory law.
3. Liability for culpable injury of life, limb or health shall remain unaffected; this
also applies for the absolute liability under the Produkthaftungsgesetz (Product
Liability Law).
4. As far as liability by TRITEC is excluded or limited, this shall also apply for the
personal liability of its executive personnel, workers, employees, representatives
and vicarious agents.
8 Reservation of Ownership
1. TRITEC shall reserve ownership in the goods until full payment of the purchase
price. As far as permitted by the respectively applicable legal system, TRITEC shall
reserve ownership in the goods regarding contracts with companies until the
receipt of all payments from the business relationship with the customer.
2. In case of the customers conduct in violation of the contract in particular, in
default of payment TRITEC shall be entitled to repossess the goods. This claim
for restitution of property shall only be considered a rescission of contract if
TRITEC explicitly declares it in writing. After repossession of the goods, TRITEC
shall be entitled to their realization; the realization proceeds shall be credited to
the customers liabilities minus reasonable costs of realization.
3. The customer shall be obligated to handle the goods with care; in particular,
the customer shall be obligated to adequately insure them, at his/her own costs,
for their reinstatement value against damage due to fire, water, and theft.
If maintenance and inspection work is required, the customer shall carry them
out in due time at his/her own costs.
4. In the event of attachment/execution or other interventions by third parties,
the customer shall notify TRITEC immediately in writing so that TRITEC can take
corresponding defense measures. As far as a third party is unable to reimburse
TRITEC for the legal and extrajudicial costs of a defense measure, the customer
shall be liable for the loss which we incurred.
5. The customer shall be entitled to further sell the goods in proper business procedures; however, the customer already now assigns to TRITEC all receivables in
the amount of the final invoice total (including sales tax) of the TRITEC receivable which he/she accrues from the further sale versus its buyers or third parties,
irrespective of whether the goods have been further sold without or after
processing. The customer shall remain entitled to collect this receivable even after the assignment. TRITECs right to collect the receivable itself shall remain unaffected thereby. However, TRITEC agrees not to collect the receivable as long as
the customer meets his/her payment obligations from the proceeds obtained,
is not in default of payment and in particular, as long as no application for the
institution of settlement or insolvency proceedings has been made, or as long as
there is no payment stop. But if this is the case, TRITEC may demand that the
customer discloses to TRITEC the assigned receivables and their debtors, provides
all necessary information for the collection, hands over the pertinent documents, and informs debtors (third parties) of the assignment.
6. TRITEC agrees to release the securities to which it is entitled upon the customers request insofar as the realizable value of our securities exceeds the receivables to be secured by more than 10 %; TRITEC shall be responsible for selecting
the securities to be released.
7. For leased articles, the customer shall be obligated to return the leased object
on-time and in proper, clean and functioning condition. The customer shall
accept full liability for any damage due to improper use, or theft, vandalism, accidents or the like. Every customer shall take care on its own for any repairs. If
articles are lost which are necessary for the functioning of the leased article, they
shall be principally invoiced to the customer. The customer shall take out insurance for the leased articles.
9 Design Changes
We reserve the right to make design changes at any time; however, we shall not
be obligated to make any such changes even on already delivered products.
10 Secrecy
Unless otherwise explicitly agreed upon in writing, the information submitted to

us in connection with orders shall not be considered confidential.


11 Export
Any re-export of delivered goods from the territory of the European Union shall
be subject to the country-specific export provisions and is possibly not allowed
without an official permit. Export of the delivered goods from the territory of
the European Union shall require the suppliers written consent; irrespective
thereof, the customer shall obtain on his/her own any official import and export
permits. The customer shall be responsible for compliance with the pertinent
provisions up to the end consumer.
12 Final Provisions
1. These General Terms and Conditions and the entire legal relations between
the customer and TRITEC shall be governed by the law at the registered seat of
the company where the order has been placed, with the exclusion of the Vienna
UN-Convention on Contracts for the International Sale of Goods.
2. Legal venue for any disputes resulting directly or indirectly from the contractual relationship shall be exclusively at the registered seat of the company where
the order has been placed.
3. Above, the respectively acting enterprise of the TRITEC Group has been designated as TRITEC. The contracting party shall acknowledge this and agrees that,
with this type of designation, the individual enterprises of the TRITEC Group do
not trigger any group liability.
4. Should any provision in these General Terms and Conditions or a provision
within the scope of other agreements be or become invalid, the validity of any
other provisions or agreements shall not be affected thereby. Instead of the
invalid provision or to fill a gap, a regulation shall be agreed upon which as far
as legally allowed comes closest to what the contracting parties had wanted.
5. The General Terms and Conditions are translated in several languages. The
German version shall be ruling in case of any inconsistencies or in case of
doubt.
General Terms and Conditions by the TRITEC Group for Commerce
Issued: October 2008

197

TRITEC Contacts

198

TRITEC Services AG
Herrenweg 60
4123 Allschwil / Basel, Schweiz
P +41 61 699 35 55
F +41 61 699 35 99
info@tritec-energy.com

TRITEC Deutschland GmbH


Basler Strae 115
79115 Freiburg i. B., Deutschland
P +49 761 400 689 22
F +49 761 400 689 90
deutschland@tritec-energy.com

TRITEC Project Engineering AG


Herrenweg 60
4123 Allschwil / Basel, Schweiz
P +41 61 699 35 70
F +41 61 699 35 99
info@tritec-energy.com

TRITEC AG | Schweiz
Heckenweg 29
3270 Aarberg, Schweiz
P +41 32 665 35 35
F +41 32 665 50 33
schweiz@tritec-energy.com

TRITEC International Sales


P +49 7041 81510-325
F +49 7041 81510-390
sales@tritec-energy.com

TRITEC sterreich
P +49 761 400 689 26
F +49 761 400 689 90
oesterreich@tritec-energy.com

TRITEC International Purchasing


Solar Modules
P +41 61 699 35 56
F +41 61 699 35 99
Inverters & PV Accessories
P +49 7041 81510-315
F +49 7041 81510-390
purchasing@tritec-energy.com

TRITEC Espaa
P +49 7041 81510-311
F +49 7041 81510-390
jendrik.baumann@tritec-energy.com

TRITEC Logistics GmbH


Lugwaldstrae 17
75417 Mhlacker, Deutschland
P +49 7041 81510-0
F +49 7041 81510-390
logistics@tritec-energy.com

TRITEC France
P +41 61 699 35 76
F +41 61 699 35 99
france@tritec-energy.com
TRITEC Italia
P +49 7041 81510-311
F +49 7041 81510-390
jendrik.baumann@tritec-energy.com

TRITEC UK
P +49 7041 81510-311
F +49 7041 81510-390
uk@tritec-energy.com
TRITEC Southeastern Europe
P +49 761 400 689 26
F +49 761 400 689 90
croatia@tritec-energy.com
TRITEC Benelux
Flanders / Netherlands
P +31 618 1761 48
Wallonia / Brussels / Luxembourg
P +49 7041 81510-325
benelux@tritec-energy.com
TRITEC Greece
15125 Marousi
Athens, Greece
M +30 694 912 28 00
greece@tritec-energy.com
TRITEC Chile
TRITEC INTERVENTO SpA
Calle Doctor Manuel Barros
Borgoo N 346, Providencia,
Santiago de Chile, Chile
P +56 2 2 445 89 32
chile@tritec-energy.com
TRITEC South Africa
P +41 61 699 35 67
F +41 61 699 35 99
info@tritec-energy.com

Imprint
TRITEC Services AG, a member of TRITEC Group.
TRITEC Services AG | Version 20140828

The German version is binding.


The content is subject to change without prior notice.
The current version is available from www.tritec-energy.com.

199

www.tritec-energy.com

You might also like