DAT 72 Serv Guide
DAT 72 Serv Guide
Useful links
HP Library and Tape Tools (www.hp.com/support/tapetools)
Performance help (www.hp.com/support/pat)
Compatibility help (www.hp.com/go/connect)
HP DDS Manuals
Warranty information
HP Support contact information
Software/application issue
Try in the following order:
1. Run Library and Tape Tools Device Analysis test.
2. Check driver is correct and installed.
3. If Windows NT4 - check driver location in the operating system.
4. If Windows NT4 - check SCSI connectivity.
5. If Windows NT4 - check tape device detected by operating system.
6. If Windows NT4 - check if native driver is loaded.
7. If Windows 2000 - check driver location in the operating system.
8. If Windows 2000 - check if there is a plug and play issue.
9. If Windows 2000 - check for driver issues.
10. If Windows 2000 - check removable storage manager.
11. Check system event logs.
Action recommended
Run the Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product.
Additional information
Click here for information on drivers and
operating systems.
Additional information
Click here for information on tape
drive detection and other
Action recommended
Additional information
considerations in Windows NT4 and
2000 operating systems.
Additional information
Additional information
Click here for information on tape drive
detection and other considerations in
Windows NT4 and 2000 operating
systems.
Additional information
Click here for information on tape
drive detection and other
considerations in Windows NT4 and
2000 operating systems.
Action recommended
Additional information
2000 operating systems.
NOTE:
Third party ISV backup software
loads its own device drivers and
does not appear in the Drivers
icon (check Control Panel under
Tape Devices and select
Drivers.)
NOTE:
If both the native and ISV driver
are loaded then you may get
driver timeout errors as both will
be trying to access the tape drive
simultaneously.
Additional information
Click here for information on tape drive
detection and other considerations in
Windows NT4 and 2000 operating
systems.
Action recommended
Compare driver properties like
version and file size with the correct
downloaded version from the hp.com
Web site.
Additional information
Click here to visit
www.hp.com/support/dat.
Additional information
Additional information
Click here for information on tape drive detection
and other considerations in Windows NT4 and
2000 operating systems.
Additional information
Action recommended
Additional information
RSM can cause other issues related to backup Click here for information on
devices so be aware that it resides in Services resolving issues caused by RSM
and will need to be disabled.
(Removable Storage Manager).
Back to Start of Section
Back to Top
Check system event logs
Action
recommended
Check the system
event logs.
Additional information
Click here for information on tape drive detection and
other considerations in Windows NT4 and 2000 operating
systems.
Additional information
Click here for information on tape
drive detection and other
considerations in Windows NT4 and
2000 operating systems.
Additional information
Click here for information on
tape drive detection and other
considerations in Windows NT4
and 2000 operating systems.
Action recommended
Additional information
Additional information
Click here to visit
www.hp.com/go/connect.
Additional information
Click here to visit
www.hp.com/go/connect.
Additional information
Additional information
Contact HP Support.
LEDs issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
Additional information
Click here for information on the
HP DAT front panel LEDs.
Action recommended
Check the power cable is plugged in and power is switched
on.
Check the drive power switch is turned on.
If a tape is not loaded, load a data cartridge. The green
Tape LED should flash slowly while the tape loads, then
stay on to indicate that a tape is loaded.
If the LEDs are still off, power cycle the drive or press the
Emergency Reset button.
Additional information
Click here for information on
the HP DAT front panel LEDs.
Action recommended
Additional information
NOTE:
Unloading a tape can take a few minutes
due to the rewind required.
Back to Start of Section
Back to Top
Check if green Tape LED is flashing rapidly
Action recommended
REASON: The drive mechanism is operating
(for instance, writing, reading, spacing).
Additional information
Click here for information on the
HP DAT front panel LEDs.
Additional information
Click here for information on the
clean light flashing on DAT
drives.
Click here for information on the
HP DAT front panel LEDs.
Additional
information
Click here for
information on the
clean light flashing
on DAT drives.
Click here for
information on the
HP DAT front panel
Action recommended
Additional
information
LEDs.
Additional
information
Click here for
information DDS
media care.
Click here for
Action recommended
Additional
information
information on the
HP DAT front panel
LEDs.
Additional
information
Action recommended
Additional
information
product.
Additional
information
Action recommended
Additional
information
Additional
information
Click here for
information on the
HP DAT front panel
LEDs.
Additional
information
Action recommended
Additional
information
Additional
information
Action
recommended
Additional information
Contact HP Support.
Back-up issue
Try in the following order:
1. Run Device Analysis Test in Library and Tape Tools.
2. Run Read/Write Test in Library and Tape Tools.
3. Run Media Validation Test in Library and Tape Tools.
4. Upgrade to latest firmware.
5. Check back-up logs.
6. Check you are using a supported configuration and correct media.
7. Check if verify has failed.
8. Check if the scheduled back-up has failed.
9. Check for media damage.
10. Check that the drive has been cleaned.
11. Check for back-up software issues.
12. Check you can format a tape.
13. Check IRQ assigning.
14. HP Support contact details.
Additional
information
Additional
information
Action recommended
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Run Read/Write Test in Library and Tape Tools
Action recommended
Additional information
Additional
information
Additional
information
Action recommended
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Upgrade to latest firmware
Additional
information
Action recommended
Upgrade to latest firmware using HP Library and Tape
Tools (L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Additional information
Click here to visit
www.hp.com/go/connect.
Action recommended
Check you are using correct media.
Additional information
Click here for a DDS media compatibility
matrix.
Additional information
Action recommended
If your scheduled backup has failed, check that the files to be
backed up are actually present on the target directory and
available to be backed-up.
Back to Start of Section
Back to Top
Check for media
Action recommended
Additional information
Click here for information on how
to detect a damaged DDS
cartridge and what symptoms
would be seen.
Additional information
Additional information
Additional information
Action recommended
Additional
information
This happens when two devices which are unlike are assigned
the same IRQ.
Both PM HP and PM Compaq Servers can end up with incorrect
IRQ routing due to automatic IRQ routing in their BIOS. This
can cause issues with both drivers and performance.
To correct this problem you will need to manually assign the
IRQ' s via the system BIOS taking into account any shared
slots with onboard-embedded devices, etc.
Always assign IRQ' s at a hardware level in the system BIOS
and not in the Operating System.
Back to Start of Section
Back to Top
HP Support contact details
Action
recommended
Additional information
Contact HP Support.
Restore issues
Try in the following order:
1. Check if you have data (the required files) on your tape.
2. Run Device Analysis Test in Library and Tape Tools.
3. Run Media Validation Test in Library and Tape Tools.
4. Check if verify has failed.
5. Check the target device is accessible.
6. Check for media damage.
7. Check the drive has been cleaned.
8. Check you are using a supported configuration.
9. Upgrade to latest firmware.
10. HP Support contact details.
Additional information
Additional
information
Additional
information
Additional
information
Action recommended
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Check if verify has failed
Action recommended
Additional information
Additional information
Additional information
Click here for information on how
to detect a damaged DDS
cartridge and what symptoms
would be seen.
Click here for information on
visually inspecting HP DDS media.
Click here for information on DDS
media label placement.
Click here for information DDS
Action recommended
Additional information
media care.
Click here for information on
ensuring a long life for the HP DAT
product.
Additional information
Additional information
Additional
information
NOTE:
Additional
information
Action recommended
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Contact HP Support.
Additional information
Action recommended
Additional information
unable to eject.
Click here for information on
how to detect a damaged DDS
cartridge and what symptoms
would be seen.
Additional information
Action recommended
Additional information
Click here for information on
ensuring a long life for the HP
DAT product.
Action recommended
Power cycle the drive.
Power cycle the server to re-scan the SCSI bus.
Allow up to five minutes for the drive to become ready
again.
Back to Start of Section
Back to Top
Check for conflicts in backup software services
Action recommended
Additional information
Additional information
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here for information on SCSI
cables and termination.
Click here for information on SCSI
Action recommended
Additional information
terminated.
Action recommended
Check that the software has not sent the tape drive a
prevent media removal command to prevent an
accidental eject. Check with the backup application
software vendor on how to change this option and send
the drive an enable media removal command to restore
control to the eject switch. Alternatively, a SCSI reset
will have the same effect.
Additional
information
Click here for
information on the
media being jammed
and unable to eject.
Additional
information
Additional
information
Additional
information
Action recommended
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
HP Support contact details
Action
recommended
Additional information
Contact HP Support.
Additional
information
Click here for
information on HP
Library and Tape
Tools.
Action recommended
Additional
information
Additional
information
Action recommended
Additional information
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here for information on SCSI
cables and termination.
Action recommended
Additional information
ensuring a long life for the HP DAT
product.
Additional information
Click here for information on the HP DAT front panel
LEDs.
Check LEDs
Back to Start of Section
Back to Top
Swap drive to a known good system and test using Library and Tape Tools
Additional
information
Action recommended
Swap the drive to a known good/working system, then test
communications to the drive using Library and Tape Tools.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Click here for information on how to detect
a damaged DDS cartridge and what
symptoms would be seen.
Click here for information on visually
Action recommended
Additional information
inspecting HP DDS media.
Click here for information on DDS media
label placement.
Click here for information DDS media care.
Click here for information on ensuring a
long life for the HP DAT product.
Action recommended
Re-run HP Library and Tape Tools (L&TT) to re-check
connectivity to the drive.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Contact HP Support.
Media issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Additional information
Click here for a DDS media compatibility
matrix.
Additional
information
Action recommended
Additional information
Click here for information on how to
detect a damaged DDS cartridge
and what symptoms would be seen.
Click here for information on
visually inspecting HP DDS media.
Additional information
Additional
information
Click here for
information on DAT
autoloaders front panel.
Click here for
Additional
information
Action recommended
information on
Autoloader LCD
Messages.
Repeat the clean five times in total.
Check for expiry of cleaning tape.
Check the environmental conditions of the drive and
media storage.
Additional
information
Additional
information
Action recommended
cannot be support by HP if your duty cycle is >12% (more
than two tapes per day).
Back to Start of Section
Back to Top
Additional
information
Additional information
Click here for a DDS media compatibility matrix.
Click here for information DDS media care.
More information on
DDS media.
Action
recommended
Additional information
media.
Click here for information on DDS media label
placement.
Click here for information on the Defective Media
Exchange process for Travan, DDS, MO, CDR/RW media
(Warranty Process).
Additional information
Contact HP Support.
Performance issue
Try in the following order:
1.
2.
3.
4.
5.
Additional information
Additional information
Action recommended
Additional information
Additional
information
Click here for
information on HP
Additional
information
Action recommended
given with the test results.
Additional information
Click here for information on HP Surestore
DAT, DLT, DLT1 and DLTVS80
Performance (Capacity and Speed).
Information on performance
troubleshooting and using
performance assessment tools.
Additional information
Contact HP Support.
Back to Top
Check compression.
Check media type.
Check file system for zip files.
Check performance of drive using Library and Tape Tools.
HP Support contact details.
Additional information
Click here for information on HP
Surestore DAT, DLT, DLT1 and
DLTVS80 Performance (Capacity and
Speed).
Additional information
Click here for a DDS media compatibility
matrix.
Additional
information
Action recommended
Run Device Analysis Test from Test drop down menu in HP
Library and Tape Tools (L&TT). Follow any troubleshooting
given with the test results.
Run the Read/Write test in L&TT. Check ERT performance
in the support ticket.
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Contact HP Support.
Load/unload issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
Additional
information
o
o
o
o
Action recommended
Additional
information
Additional
information
Try loading a tape into the tape drive. If the tape loads,
but then ejects again, follow the steps listed below.
Check correct media is being used.
Action recommended
Additional
information
placement.
Click here for
information DDS
media care.
Click here for
information on
ensuring a long life
for the HP DAT
product.
Action recommended
Additional
information
Action recommended
Additional
information
Click here for
information DDS media
care.
Click here for
information on ensuring
a long life for the HP
DAT product.
Additional
information
Click here for
information on media
jammed and unable to
eject.
Action recommended
o
Additional
information
o
o
o
o
Additional
information
Action recommended
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If tape did not eject, see "Stuck Tape
Troubleshooting" for further troubleshooting help.
Additional
information
Click here for
information on media
jammed and unable to
eject.
Additional
information
Action recommended
Additional
information
Additional
information
Action recommended
Additional information
Contact HP Support.
Installation/configuration issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
Additional information
Action recommended
Additional information
www.hp.com/go/connect.
Additional information
Additional information
Additional information
Additional information
Click here for information on drivers and
operating systems.
Action recommended
Check connectivity with HP Library and Tape Tools (L&TT).
Run Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
See the Software/Application Issue
troubleshooting section.
Additional information
Contact HP Support.
Read/write issue
Try in the following order:
1.
2.
3.
4.
5.
6.
Additional
information
Additional
information
Additional
information
Action recommended
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Test media using Media Validation Test in Library and Tape Tools
Additional
information
Action recommended
Run the Media Validation Test in HP Library and Tape Tools
(L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Click here for information on
clean light flashing on DAT
Drives.
Action recommended
Additional information
Snapped/damaged tape
Action recommended
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Action
recommended
Additional information
Contact HP Support.
Cleaning issues
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Additional
information
Action recommended
Additional
information
Additional information
Click here for information on the
clean light flashing on DAT
drives.
Click here for information on the
HP DAT front panel LEDs.
Additional
information
Click here for
information on the
clean light flashing
on DAT drives.
Action recommended
Additional
information
Additional
information
Click here for
information DDS
media care.
Action recommended
Additional
information
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected
Back to Start of Section
Back to Top
If DAT72, check if the cleaning tape is held by the drive for more than two minutes
after loading and the green Tape LED is FLASHING
Action recommended
Additional
information
Action recommended
Additional
information
Additional
information
Additional
information
Action recommended
Run the Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
Run the recalibration script for DAT24 drives.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Additional information
Contact HP Support.
Additional information
Action
recommended
Additional information
Information on part
numbers.
Information on
compatibility.
Additional information
Contact HP Support.