HP StorageWorks DAT - Troubleshooting for HP

StorageWorks DAT8, DAT24, DAT40, and DAT72


Introduction
This document provides troubleshooting steps for some of the most common issues along with links
for additional information if needed. Also, a list of other useful links is listed below.

Troubleshooting issue symptoms


Software/application issue
LEDs issue
Back-up problem
Restore problem
Stuck tape
Drive hung (communication failure)
Media problem
Performance issue
Capacity Loss
Load/unload problem
Installation/configuration issue
Read/write problem
Cleaning issue
Broken/wrong/missing part

Useful links
HP Library and Tape Tools (www.hp.com/support/tapetools)
Performance help (www.hp.com/support/pat)
Compatibility help (www.hp.com/go/connect)
HP DDS Manuals
Warranty information
HP Support contact information

Software/application issue
Try in the following order:
1. Run Library and Tape Tools Device Analysis test.
2. Check driver is correct and installed.
3. If Windows NT4 - check driver location in the operating system.
4. If Windows NT4 - check SCSI connectivity.
5. If Windows NT4 - check tape device detected by operating system.
6. If Windows NT4 - check if native driver is loaded.
7. If Windows 2000 - check driver location in the operating system.
8. If Windows 2000 - check if there is a plug and play issue.
9. If Windows 2000 - check for driver issues.
10. If Windows 2000 - check removable storage manager.
11. Check system event logs.

Field Code Changed

12. Decode driver errors.


13. Check application event logs.
14. Check if you have a Netware operating system issue.
15. Check if you have a Tapeware software issue.
16. Check if you have a Colorado Backup issue.
17. Check if you have an Arcserve issue.
18. HP Support contact details.

Software/application troubleshooting details


Run Device Analysis test in Library and Tape Tools
Additional
information

Action recommended
Run the Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product.

Click here for


information on HP
Library and Tape
Tools.

This problem only relates to the Q1546A product, no other


DAT 40 variants are affected.
Back to Start of Section
Back to Top
Check driver is correct and installed
Action recommended
Check driver is correct and
installed.

Additional information
Click here for information on drivers and
operating systems.

Back to Start of Section


Back to Top
If NT4 - check driver location in the operating system
Action recommended
Check operating system drivers in the
winnt/system32/drivers directory.

Additional information
Click here for information on tape
drive detection and other

Action recommended

Additional information
considerations in Windows NT4 and
2000 operating systems.

Compare driver properties like version


and file size with the correct downloaded
version from the hp.com Web site.

Click here for information on drivers


and operating systems.

Back to Start of Section


Back to Top
If NT4 - check SCSI connectivity
Action recommended

Additional information

Check Control Panel, then


SCSI Adapters.

Click here for information on tape drive


detection and other considerations in
Windows NT4 and 2000 operating systems.

Select the correct SCSI adapter


and check that the tape device
can be seen.

Click here for information on tape drive


detection and other considerations in
Windows NT4 and 2000 operating systems.

Back to Start of Section


Back to Top
If NT4 - check tape device detected by operating system
Action recommended
Check the tape devices icon in the
Control Panel, to display the tape
drive model or type.
(Select Detect to rescan the bus
for attached tape devices).

Additional information
Click here for information on tape drive
detection and other considerations in
Windows NT4 and 2000 operating
systems.

Back to Start of Section


Back to Top
If NT4 - check if native driver is loaded
Action recommended
Check the Drivers tab to see if a native
driver is listed. If a driver is loaded here
then be aware that this will not suffice
for ISV backup software such as
ARCserve and Backup Exec. Check the
properties of the driver to confirm.

Additional information
Click here for information on tape
drive detection and other
considerations in Windows NT4 and
2000 operating systems.

Click here for information on tape


Check Control Panel, Devices to check
drive detection and other
if a device driver is loaded.
considerations in Windows NT4 and

Action recommended

Additional information
2000 operating systems.

NOTE:
Third party ISV backup software
loads its own device drivers and
does not appear in the Drivers
icon (check Control Panel under
Tape Devices and select
Drivers.)

Click here for information on tape


drive detection and other
considerations in Windows NT4 and
2000 operating systems.

NOTE:
If both the native and ISV driver
are loaded then you may get
driver timeout errors as both will
be trying to access the tape drive
simultaneously.

Click here for information on tape


drive detection and other
considerations in Windows NT4 and
2000 operating systems.

Remove native drivers and run the


hardware configuration wizard where
applicable on the ISV software in order
to install and use the correct driver.

Click here for information on tape


drive detection and other
considerations in Windows NT4 and
2000 operating systems.

If Microsoft service pack installed you


will need to reload the correct drivers as
Microsoft service packs can overwrite HP
drivers.

Click here for information on tape


drive detection and other
considerations in Windows NT4 and
2000 operating systems.

For Proliant Servers re-run Softpaq on


the Server obtainable from the hp.com
Web site.

Click here for information on tape


drive detection and other
considerations in Windows NT4 and
2000 operating systems.
Click here to visit
www.hp.com/support/dat.

Click here for information on tape


Check system event logs for indication of drive detection and other
driver errors/timeouts, etc.
considerations in Windows NT4 and
2000 operating systems.
Back to Start of Section
Back to Top
If Windows 2000 - check driver location in the operating system
Action recommended
Operating system drivers can be
found in the winnt/system32/drivers
directory.

Additional information
Click here for information on tape drive
detection and other considerations in
Windows NT4 and 2000 operating
systems.

Action recommended
Compare driver properties like
version and file size with the correct
downloaded version from the hp.com
Web site.

Additional information
Click here to visit
www.hp.com/support/dat.

Back to Start of Section


Back to Top
If Windows 20000 - check if there is a plug and play issue
Action recommended

Additional information

Windows 2000 is plug and play so be aware of its


related issues.

Click here for information


on tape drive detection
and other considerations
in Windows NT4 and 2000
operating systems.

Check if the drive is detected and check the driver


properties in Device Manager, Computer
Management, Administrative Tools, then select
Tape Devices. If a native driver is loaded then
under driver details it will state either Microsoft or
some other version of a HP driver, which will allow
native backup applet support.

Click here for information


on tape drive detection
and other considerations
in Windows NT4 and 2000
operating systems.

Back to Start of Section


Back to Top
If Windows 2000 - check for driver issues
Action recommended
If you are using Windows
2000, check for driver
issues.

Additional information
Click here for information on tape drive detection
and other considerations in Windows NT4 and
2000 operating systems.

Back to Start of Section


Back to Top
If Windows 2000 - check removable storage manager (RSM)
Action recommended

Additional information

Click here for information on


tape drive detection and other
Removable storage manager (which can be
considerations in Windows NT4
found in Services) comes enabled in windows
and 2000 operating systems.
by default. It should however be set to
Disabled unless you are using native backup
Click here for information on
in Windows 2000.
resolving issues caused by RSM
(Removable Storage Manager).

Action recommended

Additional information

RSM can cause problems in backup including


compression issues.

Click here for information on


resolving issues caused by RSM
(Removable Storage Manager).

If an issue with RSM is suspected then a


reboot will be necessary after setting it to
Disable.

Click here for information on


resolving issues caused by RSM
(Removable Storage Manager).

RSM can cause other issues related to backup Click here for information on
devices so be aware that it resides in Services resolving issues caused by RSM
and will need to be disabled.
(Removable Storage Manager).
Back to Start of Section
Back to Top
Check system event logs
Action
recommended
Check the system
event logs.

Additional information
Click here for information on tape drive detection and
other considerations in Windows NT4 and 2000 operating
systems.

Back to Start of Section


Back to Top
Decode driver errors
Action recommended
Error messages generated by the
adpu160m.sys driver can be viewed by
opening the Windows NT Event Viewer
error logs.

Additional information
Click here for information on tape
drive detection and other
considerations in Windows NT4 and
2000 operating systems.

Back to Start of Section


Back to Top
Check application event logs
Action recommended
Check the Application Event Log and expand it
further by double-clicking on the event. If, for
example, your license is not correct for your
backup application then the backup
application will not work.

Additional information
Click here for information on
tape drive detection and other
considerations in Windows NT4
and 2000 operating systems.

Back to Start of Section


Back to Top
Check if you have a Netware Operating System issue

Action recommended

Additional information

Check if you have a Netware Operating System issue


Back to Start of Section
Back to Top
Check if you have a Tapeware Software issue
Action recommended
Check compatibility with Tapeware.

Additional information
Click here to visit
www.hp.com/go/connect.

Check for Windows 2000 error 1067Unable to open system mutex.


Check for Windows 95/98/NT Unable
to access restore/backup or Error
74 - Object already locked on a
restore in TapeWare.
Check for Windows NT Invalid
Windows Application error.
Check if scheduled backup did not
run.

Click here for information on TapeWare


scheduled backup not running.

Check for Windows 2002/Tapeware


lite System MuTest error .

Click here for information on Installing


HP TapeWare Lite in Windows 2000
causing a System MuTest error.

Check for Error 1506 when starting


backup.

Click here for information on TapeWare


and Error 1506.

If Windows 2000, check for problems


with OBDR.

Click here for information on problems


with TapeWare one button disaster
recovery in Windows.

Check if clean option is greyed out.

Click here for information on the Clean


Option being greyed out in TapeWare.

Check for other common issues with


Tapeware.

Click here for information on common


issues with TapeWare 6.0(XE) backup
software.

Back to Start of Section


Back to Top
Check if you have a Colorado Backup issue
Action recommended
Check compatibility with Colorado
Backup.
Back to Start of Section
Back to Top

Additional information
Click here to visit
www.hp.com/go/connect.

Check if you have an Arcserve issue


Action recommended

Additional information

Check compatibility with


Arcserve.

Click here to visit www.hp.com/go/connect.

Check if after replacing a drive,


ARCserve reports that the drive
is offline.

Click here for information on after replacing


the drive, ARCserver reports that the drive is
offline.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

LEDs issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.

Check LEDs to determine the status of your drive.


Check if all LEDs are off.
Check if green Tape LED is flashing slowly.
Check if green Tape LED is flashing rapidly.
Check if amber Clean LED is flashing.
Check if amber Clean LED is triggered regularly despite cleaning.
If DAT8/24/40, check if the cleaning tape is ejected quickly (less than 20 seconds) after
loading and the green Tape LED is FLASHING.
8. If DAT72, check if the cleaning tape is held by the drive for more than 2 minutes after
loading and the green Tape LED is FLASHING.
9. Check if the amber Clean LED is on constantly.
10. Check if the drive is in OBDR mode (Tape Error and Clean LEDs flashing slowly).
11. Run Device Analysis Test in Library and Tape Tools.
12. Upgrade to latest firmware.
13. HP Support contact details.

LEDs troubleshooting details


Check LEDs to determine the status of your drive
Action recommended
Check LEDs and confirm drive status by
checking the front panel LEDs document.

Additional information
Click here for information on the
HP DAT front panel LEDs.

Back to Start of Section


Back to Top
Check if all LEDs are off
Additional
information

Action recommended
Check the power cable is plugged in and power is switched
on.
Check the drive power switch is turned on.
If a tape is not loaded, load a data cartridge. The green
Tape LED should flash slowly while the tape loads, then
stay on to indicate that a tape is loaded.

Click here for


information on the
HP DAT front panel
LEDs.

If the LEDs are still off, power cycle the drive or press the
Emergency Reset button.

Click here for


information on the
HP DAT front panel
LEDs.

If you are still concerned about the status of your drive


run the Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Check if green Tape LED is flashing slowly
Action recommended
Reason: The tape is either loading or unloading.
This is a transient state. Wait for the tape to
finish loading or unloading, or for the drive to
report an error.

Additional information
Click here for information on
the HP DAT front panel LEDs.

Action recommended

Additional information

NOTE:
Unloading a tape can take a few minutes
due to the rewind required.
Back to Start of Section
Back to Top
Check if green Tape LED is flashing rapidly
Action recommended
REASON: The drive mechanism is operating
(for instance, writing, reading, spacing).

Additional information
Click here for information on the
HP DAT front panel LEDs.

Back to Start of Section


Back to Top
Check if amber Clean LED is flashing
Action recommended

Insert a cleaning cartridge into the drive and


wait for the clean to take place. The tape is
ejected at the end.

Additional information
Click here for information on the
clean light flashing on DAT
drives.
Click here for information on the
HP DAT front panel LEDs.

Repeat the clean five times in total.


Check for expiry of cleaning tape.
Introduce a regular clean into your backup
strategy.

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check if amber Clean LED is triggered regularly despite cleaning
Action recommended

Clean the drive five times.

Additional
information
Click here for
information on the
clean light flashing
on DAT drives.
Click here for
information on the
HP DAT front panel

Action recommended

Additional
information
LEDs.

Check for expiry of cleaning tape.

Check frequency of cleaning in backup strategy.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Check environmental conditions of drive and media


storage

Click here for


information DDS
media care.

Replace data tape with new tape, it may be worn or at


end of life.

Click here for


information DDS
media care.

If problems persist, run the Device Analysis Test in HP


Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Ensure the latest firmware is loaded.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected
Back to Start of Section
Back to Top
If DAT8/24/40, check if the cleaning tape is ejected quickly after loading and the
green Tape LED is FLASHING
Action recommended

Check that the cleaning cartridge has been used less


that 50 times.

Additional
information
Click here for
information DDS
media care.
Click here for

Action recommended

Additional
information
information on the
HP DAT front panel
LEDs.

Try a new cleaning cartridge.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected
Back to Start of Section
Back to Top
If DAT72, check if the cleaning tape is held by the drive for more than two minutes
after loading and the green Tape LED is FLASHING
Action recommended

Additional
information

Eject the cleaning tape using the Eject button (later


firmware will retain the cleaning tape, including premerger Compaq drives).

Click here for


information on the
HP DAT front panel
LEDs.

Check that the cleaning cartridge has been used less


than 50 times.

Click here for


information DDS
media care.

Try a new cleaning cartridge.

Click here for


information on
ensuring a long life
for the HP DAT

Action recommended

Additional
information
product.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
Back to Start of Section
Back to Top
Check if the amber Clean LED is on constantly
Action recommended

Additional
information

REASON: The drive has experienced a hard failure.

Click here for


information on the
HP DAT front panel
LEDs.

Power cycle the drive to see if it recovers normally.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose

Click here for


information on HP
Library and Tape
Tools.

Action recommended

Additional
information

potential issues with the DAT 40 Hotplug drive


(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
Back to Start of Section
Back to Top
Check if the drive is in OBDR mode (Tape Error and Clean LEDs flashing slowly)
Action recommended
Check if the drive is in OBDR mode (Tape Error and Clean
LEDs flashing slowly).

Additional
information
Click here for
information on the
HP DAT front panel
LEDs.

If OBDR mode is not required then power cycle the drive


to stop the OBDR function.
If the drive does not recovery properly, run the Device
Analysis Test in HP Library and Tape Tools (L&TT). Follow
any troubleshooting given with the test result.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Run Device Analysis Test in L&TT
Action recommended

Additional
information

Action recommended

Additional
information

Run the Device Analysis Test in HP Library and Tape Tools


(L&TT). Follow any troubleshooting given with the test
results.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Upgrade to latest firmware
Action recommended

Additional
information

Upgrade to latest firmware.


NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
HP Support contact details

Click here for


information on HP
Library and Tape
Tools.

Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Back-up issue
Try in the following order:
1. Run Device Analysis Test in Library and Tape Tools.
2. Run Read/Write Test in Library and Tape Tools.
3. Run Media Validation Test in Library and Tape Tools.
4. Upgrade to latest firmware.
5. Check back-up logs.
6. Check you are using a supported configuration and correct media.
7. Check if verify has failed.
8. Check if the scheduled back-up has failed.
9. Check for media damage.
10. Check that the drive has been cleaned.
11. Check for back-up software issues.
12. Check you can format a tape.
13. Check IRQ assigning.
14. HP Support contact details.

Back-up troubleshooting details


Run Device Analysis Test in Library and Tape Tools
Action recommended

Additional
information

Run the Device Analysis Test in HP Library and Tape Tools


(L&TT). Follow any troubleshooting given with the test
results.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Run Read/Write Test in Library and Tape Tools
Action recommended

Additional information

Run the Read / Write test in HP Library and Tape


Tools (L&TT).
NOTE:
Due to issues in development Library and
Tape Tools cannot be reliably used to
Click here for information
diagnose potential issues with the DAT 40
Hotplug drive (Q1546A only). This problem is on HP Library and Tape
Tools.
currently being investigated and will be
corrected in the next revision of Library and
Tape tools. This note will be updated once
the problem has been corrected but until
then do not use Library and Tape Tools to
diagnose issues with this product. This
problem only relates to the Q1546A product,
no other DAT 40 variants are affected.

Check drive performance using PAT tools.

Click here for information


on performance
troubleshooting and using
performance assessment
tools.

Back to Start of Section


Back to Top
Run Media Validation Test in Library and Tape Tools
Action recommended

Additional
information

Run the Media Validation Test in HP Library and Tape Tools


(L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Upgrade to latest firmware

Additional
information

Action recommended
Upgrade to latest firmware using HP Library and Tape
Tools (L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Check back-up logs
Action recommended

Additional information

Check back-up logs.


Back to Start of Section
Back to Top
Check you are using a supported configuration and correct media
Action recommended
Check you are using a supported
configuration.

Additional information
Click here to visit
www.hp.com/go/connect.

Action recommended
Check you are using correct media.

Additional information
Click here for a DDS media compatibility
matrix.

Back to Start of Section


Back to Top
Check if verify has failed
Action recommended

Additional information

Check if verify has failed.

Check with your ISV vendor for


more information.

Check if you have open file module installed


on your backup software.

Check with your ISV vendor for


more information.

Back to Start of Section


Back to Top
Check if the scheduled back-up has failed
Additional
information

Action recommended
If your scheduled backup has failed, check that the files to be
backed up are actually present on the target directory and
available to be backed-up.
Back to Start of Section
Back to Top
Check for media
Action recommended

Additional information
Click here for information on how
to detect a damaged DDS
cartridge and what symptoms
would be seen.

Inspect your media and discard if faulty or


damaged. Check for the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect
environment
Snapped/damaged tape

Click here for information on


visually inspecting HP DDS media.
Click here for information on DDS
media label placement.
Click here for information DDS
media care.
Click here for information on
ensuring a long life for the HP DAT
product.

Back to Start of Section


Back to Top
Check that the drive has been cleaned
Action recommended

Additional information

Insert a cleaning cartridge into the drive and


wait for the clean to take place. The tape is
ejected at the end.

Click here for information on


clean light flashing on DAT
Drives.

Repeat the clean five times in total.


Check for expiry of cleaning tape.
Introduce a regular clean into your backup
strategy.

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check for back-up software issues
Action recommended

Additional information

Check whether the backup scheduler


is going off unexpectedly.

Click here for information on the tape


backup scheduler going off
unexpectedly.

Check for other common issues with


Tapeware 6.0(XE).

Click here for information on common


issues with TapeWare 6.0(XE) backup
software.

Check that virus scanning software is


not scheduled to run at the same time
as the back-up.
Check your network resources
(bandwidth, run HP PAT test).

Click here for information on


performance troubleshooting and using
performance assessment tools.

Back to Start of Section


Back to Top
Check you can format a tape
Action recommended
Try and format a tape.
Back to Start of Section
Back to Top
Check IRQ assigning

Additional information

Action recommended

Additional
information

Check for symptoms like:


o
o
o

ID9 and ID11 errors in the system event logs of


servers.
Driver errors and timeouts listed in the system
event log.
Possible IO errors in ISV logs.

This happens when two devices which are unlike are assigned
the same IRQ.
Both PM HP and PM Compaq Servers can end up with incorrect
IRQ routing due to automatic IRQ routing in their BIOS. This
can cause issues with both drivers and performance.
To correct this problem you will need to manually assign the
IRQ' s via the system BIOS taking into account any shared
slots with onboard-embedded devices, etc.
Always assign IRQ' s at a hardware level in the system BIOS
and not in the Operating System.
Back to Start of Section
Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Restore issues
Try in the following order:
1. Check if you have data (the required files) on your tape.
2. Run Device Analysis Test in Library and Tape Tools.
3. Run Media Validation Test in Library and Tape Tools.
4. Check if verify has failed.
5. Check the target device is accessible.
6. Check for media damage.
7. Check the drive has been cleaned.
8. Check you are using a supported configuration.
9. Upgrade to latest firmware.
10. HP Support contact details.

Restore troubleshooting details


Check if you have data (the required files) on your tape
Action recommended

Additional information

Check if you have data on the loaded tape.


Check that the required files are on the loaded tape.
Back to Start of Section
Back to Top
Run Device Analysis Test in Library and Tape Tools
Action recommended

Additional
information

Run the Device Analysis Test in HP Library and Tape Tools


(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Run Media Validation Test in Library and Tape Tools
Action recommended

Additional
information

Run the Media Validation Test in HP Library and Tape Tools


(L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Check if verify has failed
Action recommended

Additional information

Check if verify has failed.

Check with your ISV vendor for


more information.

Check if you have open file module installed


on your backup software.

Check with your ISV vendor for


more information.

Back to Start of Section


Back to Top
Check the target device is accessible
Action recommended

Additional information

Check that the target device is available.


Back to Start of Section
Back to Top
Check for media damage
Action recommended

Inspect your media and discard if faulty or


damaged. Check for the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect
environment
Snapped/damaged tape

Additional information
Click here for information on how
to detect a damaged DDS
cartridge and what symptoms
would be seen.
Click here for information on
visually inspecting HP DDS media.
Click here for information on DDS
media label placement.
Click here for information DDS

Action recommended

Additional information
media care.
Click here for information on
ensuring a long life for the HP DAT
product.

Back to Start of Section


Back to Top
Check that the drive has been cleaned
Action recommended

Additional information

Insert a cleaning cartridge into the drive and


wait for the clean to take place. The tape is
ejected at the end.

Click here for information on


clean light flashing on DAT
Drives.

Repeat the clean five times in total.


Check for expiry of cleaning tape.
Introduce a regular clean into your backup
strategy.

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check you are using a supported configuration
Action recommended

Additional information

Check you are using a supported


configuration.

Click here to visit


www.hp.com/go/connect.

Check you are using correct media.

Click here for a DDS media compatibility


matrix.

Back to Start of Section


Back to Top
Upgrade to latest firmware
Action recommended
Upgrade to latest firmware.

Additional
information

NOTE:

Click here for


information on HP
Library and Tape Tools.

Due to issues in development Library and Tape


Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive

Click here for


information on being
unable to upgrade

Additional
information

Action recommended
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

firmware on a DDS4/DAT40 autoloader.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Stuck tape issue


Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Manually press the Eject button.


Perform a Forced Eject.
Power cycle the drive.
Check for conflicts in backup software services.
Check SCSI/HBA/Driver configuration of the drive.
Check the software has not sent a prevent media removal command.
Run Library and Tape Tools device analysis test.
Upgrade to the latest firmware.
HP Support contact details.

Stuck tape troubleshooting details


Manually press the Eject button
Action recommended

Additional information

Press the Eject button.

Click here for information on the


media being jammed and
unable to eject.

Allow one minute for the tape to eject.

Click here for information on the


media being jammed and

Action recommended

Additional information
unable to eject.
Click here for information on
how to detect a damaged DDS
cartridge and what symptoms
would be seen.

Inspect your Media and SCSI cables, and


discard if faulty or damaged. Check for the
following:
o
o
o
o

Incorrect label placement.


Damage.
Usage in incorrect
environment.
Snapped/damaged tape.

Click here for information on


visually inspecting HP DDS
media.
Click here for information on
DDS media label placement.
Click here for information DDS
media care.
Click here for information on
ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Perform a Forced Eject
Action recommended

Additional information

Press (and hold in) the Eject button for 10


seconds

Click here for information on the


Eject button operation for the
Ultrium drive.

Allow one minute for the tape to eject.

Click here for information on the


media being jammed and
unable to eject.

Inspect your Media and SCSI cables, and


discard if faulty or damaged. Check for the
following:
o
o
o
o

Incorrect label placement.


Damage.
Usage in incorrect
environment.
Snapped/damaged tape.

Click here for information on


how to detect a damaged DDS
cartridge and what symptoms
would be seen.
Click here for information on
visually inspecting HP DDS
media.
Click here for information on
DDS media label placement.
Click here for information DDS
media care.

Action recommended

Additional information
Click here for information on
ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Power cycle the drive
Additional
information

Action recommended
Power cycle the drive.
Power cycle the server to re-scan the SCSI bus.
Allow up to five minutes for the drive to become ready
again.
Back to Start of Section
Back to Top
Check for conflicts in backup software services
Action recommended

Additional information

RSM (removable storage manager) should be


disabled for ISV software.
RSM (removable storage manager) should be
enabled for native backup applet.
Removable storage manager can be found in
Computer Management/Services in Windows 2000
and must only be used if the native backup applet is
being used. To check if in use please check Services
and see if it is started.

Click here for


information on resolving
issues caused by RSM
(Removable Storage
Manager).

Back to Start of Section


Back to Top
Check SCSI/HBA/Driver configuration of the drive
Action recommended

Ensure the power and SCSI cables are


correct, properly connected and
undamaged.

Ensure that the SCSI bus is correctly

Additional information
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here for information on SCSI
cables and termination.
Click here for information on SCSI

Action recommended

Additional information

terminated.

cables and termination.

Ensure that the tape drive SCSI ID is


correct and unique on the bus.

Click here for information on SCSI


cables and termination.

Ensure that the application being used


supports the tape drive.

Click here to visit


www.hp.com/go/connect.
Click here for information on drivers
and operating systems.

Ensure that the correct driver is loaded.


Click here to visit
www.hp.com/go/connect.
Ensure that there are no HBA problems
(check the system event log for HBA
errors).

Ensure that the host, HBA, application,


driver, and drive are all compatible.

Click here for information on


recommended SCSI HBA adapters
for tape products.
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here to visit
www.hp.com/go/connect.

Ensure there are no tape driver problems


Click here for information on HP
(check the system event log for tape
Library and Tape Tools.
driver errors).
If easy, isolate the drive so that it is the
only one on the bus.

Click here for information on SCSI


cables and termination.
Click here for information on how to
detect a damaged DDS cartridge and
what symptoms would be seen.

Inspect your Media and SCSI cables, and


discard if faulty or damaged. Check for
the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect
environment
Snapped/damaged tape

Click here for information on visually


inspecting HP DDS media.
Click here for information on DDS
media label placement.
Click here for information DDS
media care.
Click here for information on
ensuring a long life for the HP DAT
product.

Back to Start of Section


Back to Top
Check the software has not sent a prevent media removal command

Action recommended
Check that the software has not sent the tape drive a
prevent media removal command to prevent an
accidental eject. Check with the backup application
software vendor on how to change this option and send
the drive an enable media removal command to restore
control to the eject switch. Alternatively, a SCSI reset
will have the same effect.

Additional
information
Click here for
information on the
media being jammed
and unable to eject.

Back to Start of Section


Back to Top
Run Library and Tape Tools device analysis test
Action recommended

Additional
information

Run the Device Analysis Test in HP Library and Tape Tools


(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Upgrade to the latest firmware
Action recommended

Additional
information

Run HP Library and Tape Tools (L&TT) and upgrade to


latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Hung drive issue


Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.

Run Library and Tape Tools to check connectivity.


Power cycle the drive.
Check SCSI/HBA/Driver configuration of the drive.
Check LEDs.
Swap drive to a known good system and test using Library and Tape Tools.
Inspect power and SCSI cables, discard if faulty or damaged.
Re-run Library and Tape Tools to check connectivity and upgrade to latest firmware.
HP Support contact details.

Hung drive troubleshooting details


Run Library and Tape Tools to check connectivity
Action recommended
Run HP Library and Tape Tools (L&TT) to check
connectivity to the drive.
NOTE:
Due to issues in development Library and Tape

Additional
information
Click here for
information on HP
Library and Tape
Tools.

Action recommended

Additional
information

Tools cannot be reliably used to diagnose potential


issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If drive can be seen, upgrade to latest firmware.
Back to Start of Section
Back to Top
Power cycle the drive
Action recommended

Additional
information

Power cycle the drive.


Power cycle the server to re-scan the SCSI bus.
Allow up to five minutes for the drive to become ready
again.
Run HP Library and Tape Tools (L&TT) to check
connectivity to the drive.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If drive can be seen, upgrade to latest firmware.
Back to Start of Section
Back to Top
Check SCSI/HBA/Driver configuration of the drive

Click here for


information on HP
Library and Tape
Tools.

Action recommended

Ensure the power and SCSI cables are


correct, properly connected and
undamaged.

Additional information
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here for information on SCSI
cables and termination.

Ensure that the SCSI bus is correctly


terminated.

Click here for information on SCSI


cables and termination.

Ensure that the tape drive SCSI ID is


correct and unique on the bus.

Click here for information on SCSI


cables and termination.

Ensure that the application being used


supports the tape drive.

Click here to visit


www.hp.com/go/connect.
Click here for information on drivers
and operating systems.

Ensure that the correct driver is loaded.


Click here to visit
www.hp.com/go/connect.
Ensure that there are no HBA problems
(check the system event log for HBA
errors).

Ensure that the host, HBA, application,


driver, and drive are all compatible.

Click here for information on


recommended SCSI HBA adapters
for tape products.
Click here for information on
recommended SCSI HBA adapters
for tape products.
Click here to visit
www.hp.com/go/connect.

Ensure there are no tape driver problems


Click here for information on HP
(check the system event log for tape
Library and Tape Tools.
driver errors).
If easy, isolate the drive so that it is the
only one on the bus.

Inspect your Media and SCSI cables, and


discard if faulty or damaged. Check for
the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect
environment
Snapped/damaged tape

Click here for information on SCSI


cables and termination.
Click here for information on how to
detect a damaged DDS cartridge and
what symptoms would be seen.
Click here for information on visually
inspecting HP DDS media.
Click here for information on DDS
media label placement.
Click here for information DDS
media care.
Click here for information on

Action recommended

Additional information
ensuring a long life for the HP DAT
product.

Back to Start of Section


Back to Top
Check LEDs
Action
recommended

Additional information
Click here for information on the HP DAT front panel
LEDs.

Check LEDs
Back to Start of Section
Back to Top

Swap drive to a known good system and test using Library and Tape Tools
Additional
information

Action recommended
Swap the drive to a known good/working system, then test
communications to the drive using Library and Tape Tools.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Inspect power and SCSI cables, and discard if faulty or damaged
Action recommended
Inspect media, power and SCSI
cables, and discard if faulty or
damaged.

Additional information
Click here for information on how to detect
a damaged DDS cartridge and what
symptoms would be seen.
Click here for information on visually

Action recommended

Additional information
inspecting HP DDS media.
Click here for information on DDS media
label placement.
Click here for information DDS media care.
Click here for information on ensuring a
long life for the HP DAT product.

Back to Start of Section


Back to Top
Re-run Library and Tape Tools to check connectivity and upgrade to latest
firmware
Additional
information

Action recommended
Re-run HP Library and Tape Tools (L&TT) to re-check
connectivity to the drive.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

If drive can be seen, upgrade to latest firmware.


Back to Start of Section
Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Media issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Check correct media is being used.


Test media using Media Validation Test in Library and Tape Tools.
Check for media damage.
Check if the drive is cleaned regularly.
Check if Clean LED is flashing.
Check if you are using more than two tapes a day.
Run Library and Tape Tools and upgrade to latest firmware.
Media care and cleaning information.
HP Support contact details.

Media troubleshooting details


Check correct media is being used
Action recommended
Check correct media is being
used.

Additional information
Click here for a DDS media compatibility
matrix.

Back to Start of Section


Back to Top
Test media using Media Validation Test in Library and Tape Tools
Action recommended

Additional
information

Test media in L&TT using Media Validation Test from Tests


drop down list.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Check for media damage

Click here for


information on HP
Library and Tape
Tools.

Action recommended

Additional information
Click here for information on how to
detect a damaged DDS cartridge
and what symptoms would be seen.
Click here for information on
visually inspecting HP DDS media.

Inspect your media and discard if faulty


or damaged. Check for the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect
environment
Snapped/damaged tape

Click here for information on DDS


media label placement.
Click here for information DDS
media care.
Click here for information on
ensuring a long life for the HP DAT
product.
Click here for information on the
Defective Media Exchange Process
for Travan, DDS, MO, CDR/RW
Media (Warranty Process).

Back to Start of Section


Back to Top
Check if the drive is cleaned regularly
Action recommended

Additional information

Insert a cleaning cartridge into the drive and


wait for the clean to take place. The tape is
ejected at the end.
Repeat the clean five times in total.
Introduce a regular clean into your backup
strategy.

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check if Clean LED is flashing
Action recommended

Insert a cleaning cartridge into the drive and wait for


the clean to take place.

Additional
information
Click here for
information on DAT
autoloaders front panel.
Click here for

Additional
information

Action recommended

information on
Autoloader LCD
Messages.
Repeat the clean five times in total.
Check for expiry of cleaning tape.
Check the environmental conditions of the drive and
media storage.

Click here for


information on ensuring
a long life for the HP
DAT product.

Replace the data tape with a new tape, it may be


worn or at end of life.

Click here for


information DDS media
care.

Introduce a regular clean into your backup strategy.

Click here for


information on ensuring
a long life for the HP
DAT product.

Run Device Analysis Test from Test drop down menu


in HP Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape Tools.
Click here for
information on being
unable to upgrade
firmware on a DDS4/DAT40 autoloader.

Back to Start of Section


Back to Top
Check if you are using more than two tapes a day
Action recommended
Check if you are using more than two tapes a day. Your drive

Additional
information

Additional
information

Action recommended
cannot be support by HP if your duty cycle is >12% (more
than two tapes per day).
Back to Start of Section
Back to Top

Run Library and Tape Tools and upgrade to latest firmware


Action recommended

Additional
information

Run Device Analysis Test from Test drop down menu in HP


Library and Tape Tools (L&TT). Follow any troubleshooting
given with the test results.
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Media care and cleaning information
Action
recommended

Additional information
Click here for a DDS media compatibility matrix.
Click here for information DDS media care.

More information on
DDS media.

Click here for information on ensuring a long life for the


HP DAT product.
Click here for information on how to detect a damaged
DDS cartridge and what symptoms would be seen.
Click here for information on visually inspecting HP DDS

Action
recommended

Additional information
media.
Click here for information on DDS media label
placement.
Click here for information on the Defective Media
Exchange process for Travan, DDS, MO, CDR/RW media
(Warranty Process).

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Performance issue
Try in the following order:
1.
2.
3.
4.
5.

Check performance using HPTapePerf.


Performance troubleshooting steps.
Check drive using Library and Tape Tools.
Additional help on performance and using HP Performance Assessment Tools.
HP Support contact details.

Performance troubleshooting details


Check performance using HPTapePerf
Action recommended

Additional information

Click here for information on performance


Check performance using
troubleshooting and using performance assessment
HPTapePerf.
tools.
Back to Start of Section
Back to Top
Performance troubleshooting steps
Action recommended

Additional information

Action recommended

Additional information

Check the ISV software


configuration is optimized.

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).

Check if the drive is backing up


over a network (can cause poor
performance).

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).

Check the compression ratio


achieved on the drive.

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).
Click here for information on data
compression.

Check the performance of the


server using HP PAT test.

Click here for information on performance


troubleshooting and using performance
assessment tools.

Click here for information on HP Surestore


Check for other peripherals on the
DAT, DLT, DLT1 and DLTVS80 Performance
same bus.
(Capacity and Speed).
Check the SCSI adaptor set up.

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).

Check for the use of push agents.

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).

Check for the use of virus


detection software.

Click here for information on HP Surestore


DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).
Click here for information on HP Surestore
DAT, DLT, DLT1 and DLTVS80 Performance
(Capacity and Speed).

Check the media usage, old media


can cause degraded performance. Click here for information DDS media care.
Click here for information on ensuring a
long life for the HP DAT product.
Back to Start of Section
Back to Top
Check drive using Library and Tape Tools
Action recommended
Run Device Analysis Test from Test drop down menu in HP
Library and Tape Tools (L&TT). Follow any troubleshooting

Additional
information
Click here for
information on HP

Additional
information

Action recommended
given with the test results.

Library and Tape


Tools.

Run the Read/Write test in L&TT. Check ERT performance


in the support ticket.
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
Additional help on performance and using HP Performance Assessment Tools
Action recommended

Additional information
Click here for information on HP Surestore
DAT, DLT, DLT1 and DLTVS80
Performance (Capacity and Speed).

Information on performance
troubleshooting and using
performance assessment tools.

Click here for information on data


compression.
Click here for information on performance
troubleshooting and using performance
assessment tools.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section

Back to Top

Capacity loss issue


Try in the following order:
1.
2.
3.
4.
5.

Check compression.
Check media type.
Check file system for zip files.
Check performance of drive using Library and Tape Tools.
HP Support contact details.

Capacity loss troubleshooting details


Check compression
Action recommended

Additional information
Click here for information on HP
Surestore DAT, DLT, DLT1 and
DLTVS80 Performance (Capacity and
Speed).

Check the compression ratio achieved on


the drive (always enable hardware
Click here for information on data
compression and disable software
compression.
compression).

Click here for information on


performance troubleshooting and
using performance assessment tools.
Back to Start of Section
Back to Top
Check media type
Action recommended
Check correct media type is being
used.

Additional information
Click here for a DDS media compatibility
matrix.

Back to Start of Section


Back to Top
Check file system for zip files
Action recommended
Check file system for zip files (you can't compress zip
files, jpeg files, audio files, etc).
Back to Start of Section
Back to Top

Additional
information

Check performance of drive using Library and Tape Tools


Additional
information

Action recommended
Run Device Analysis Test from Test drop down menu in HP
Library and Tape Tools (L&TT). Follow any troubleshooting
given with the test results.
Run the Read/Write test in L&TT. Check ERT performance
in the support ticket.
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Load/unload issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.

Check that media can be loaded into the drive.


Check if the media is ejected after insertion .
Check if tape is stuck in the drive (not visible behind the door).
Check if the media is stuck in the drive (door partially open) .
Check if your drive is repeatedly trying to eject media.
Check if your media is ejecting after backup.
HP Support contact details.

Load/unload troubleshooting details


Check that media can be loaded into the drive
Action recommended

Additional
information

Try loading a tape into the tape drive. If you have


problems getting the tape to load, try the steps listed
below.
Check the correct media is being used.

Click here for a DDS


media compatibility
matrix.

Check the cartridge is being loaded in the correct


orientation.
Click here for
information on how
to detect a damaged
DDS cartridge and
what symptoms
would be seen.

Inspect media and SCSI cables, and discard if faulty or


damaged. Check media for the following:
Incorrect label placement
Damage
Usage in incorrect environment
Snapped/damaged tape

o
o
o
o

Click here for


information on
visually inspecting
HP DDS media.
Click here for
information on DDS
media label
placement.
Click here for
information DDS
media care.
Click here for
information on
ensuring a long life
for the HP DAT
product.

Run Device Analysis Test from Test drop down menu in


HP Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Ensure your drive is running with the latest firmware.
NOTE:

Click here for


information on HP
Library and Tape
Tools.

Action recommended

Additional
information

Due to issues in development Library and Tape


Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
For older DAT24 drives be aware that using excessive
force when inserting the media can cause damage to the
drive. This damage may lead to the drive needing to be
exchanged. This issue is not present on newer DAT24
drives

Click here for


information on
calling HP and other
ways to contact HP
for technical support.

Back to Start of Section


Back to Top
Check if the media is ejected after insertion
Action recommended

Additional
information

Try loading a tape into the tape drive. If the tape loads,
but then ejects again, follow the steps listed below.
Check correct media is being used.

Click here for a DDS


media compatibility
matrix.

Check the cartridge is being loaded in the correct


orientation
Click here for
information on how
to detect a damaged
DDS cartridge and
Inspect your Media and SCSI cables, and discard if faulty
what symptoms
or damaged. Check for the following:
would be seen.
o
o
o
o

Incorrect label placement.


Damage.
Usage in incorrect environment.
Snapped/damaged tape.

Click here for


information on
visually inspecting
HP DDS media.
Click here for
information on DDS
media label

Action recommended

Additional
information
placement.
Click here for
information DDS
media care.
Click here for
information on
ensuring a long life
for the HP DAT
product.

Click here for


Insert a cleaning cartridge into the drive and wait for the information on
clean to take place. The tape is ejected at the end.
ensuring a long life
Repeat the clean five times in total.
for the HP DAT
product.

Check your media usage (old media can cause degraded


performance). Replace the data tape with a new tape, it
may be worn or at end of life.

Click here for


information on HP
Surestore DAT, DLT,
DLT1 and DLTVS80
Performance
(Capacity and
Speed).

Run Device Analysis Test from Test drop down menu in


HP Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Ensure your drive is running with the latest firmware.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
Back to Start of Section
Back to Top
Check if the media is stuck in the drive (not visible behind door)

Action recommended

Additional
information

Check if the media is stuck in the drive (not visible


behind door).

Click here for


information on media
jammed and unable to
eject.

Try a forced eject to remove the media (press and


hold in the Eject button for 10 seconds). Allow one
minute for the tape to eject.

Click here for


information on media
jammed and unable to
eject.

Test media in L&TT using Media Validation Test from


Tests drop down list.
Run Device Analysis Test from Test drop down menu
in HP Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Upgrade to latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

If the tape ejects, inspect the media and discard if


faulty or damaged. Check for the following:
o
o
o
o

Incorrect label placement.


Damage.
Usage in incorrect environment.
Snapped/damaged tape.

Click here for


information on HP
Library and Tape Tools.

Click here for


information on how to
detect a damaged DDS
cartridge and what
symptoms would be
seen.
Click here for
information on visually
inspecting HP DDS
media.
Click here for
information on DDS
media label placement.

Action recommended

Additional
information
Click here for
information DDS media
care.
Click here for
information on ensuring
a long life for the HP
DAT product.

If the tape ejected, use the Read/Write test and the


Device Analysis test in L&TT with new media to check
that the drive is now working normally.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If tape did not eject, see "Stuck Tape
Troubleshooting" for further troubleshooting help.

Click here for


information on HP
Library and Tape Tools.

See the "Stuck Tape


Troubleshooting"
section.

Back to Start of Section


Back to Top
Check if the media is stuck in the drive (door partially open)
Action recommended
If the media appears to be stuck in the drive, check if
the drive door is partially open.
Try lifting the door and removing the media:
o

Additional
information
Click here for
information on media
jammed and unable to
eject.

Click here for


information on calling
Check if the door sticks while opening.
HP and other ways to
If it does contact HP support for help regarding
contact HP for technical
possible flash on the top of the front door, you
support.
may need a new front panel.

Action recommended
o

Additional
information

Check if the door is obstructed for any


reason (labels fallen off tapes, etc). Remove
any obstruction if possible.
If the door opens smoothly when lifted,
there is no obstruction preventing the media
from ejecting, and the tape is visible, try
removing the tape by gently pulling it out of
the drive by hand.
Click here for
information on how to
detect a damaged DDS
cartridge and what
symptoms would be
seen.

If the tape ejects, inspect the media and discard if


faulty or damaged. Check for the following:
Incorrect label placement.
Damage.
Usage in incorrect environment.
Snapped/damaged tape.

o
o
o
o

Click here for


information on visually
inspecting HP DDS
media.
Click here for
information on DDS
media label placement.
Click here for
information DDS media
care.
Click here for
information on ensuring
a long life for the HP
DAT product.

If the tape ejected, use the Read/Write test and the


Device Analysis test in L&TT with new media to check
that the drive is now working normally.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this

Click here for


information on HP
Library and Tape Tools.

Additional
information

Action recommended
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If tape did not eject, see "Stuck Tape
Troubleshooting" for further troubleshooting help.

See the "Stuck Tape


Troubleshooting"
section.

Back to Start of Section


Back to Top
Check if your drive is repeatedly trying to eject media
Action recommended
If the media appears to be stuck in the drive, check if
the drive door is partially open.

Additional
information
Click here for
information on media
jammed and unable to
eject.

Try lifting the door and removing the media:


o

Check if the door sticks while opening.


If it does contact HP support for help regarding
possible flash on the top of the front door, you
may need a new front panel.
Check if the door is obstructed for any
reason (labels fallen off tapes, etc). Remove
any obstruction if possible.
If the door opens smoothly when lifted,
there is no obstruction preventing the media
from ejecting, and the tape is visible, try
removing the tape by gently pulling it out of
the drive by hand.

If the tape ejects, inspect the media and discard if


faulty or damaged. Check for the following:
o
o
o
o

Incorrect label placement.


Damage.
Usage in incorrect environment.
Snapped/damaged tape.

Click here for


information on calling
HP and other ways to
contact HP for technical
support.

Click here for


information on how to
detect a damaged DDS
cartridge and what
symptoms would be
seen.
Click here for
information on visually
inspecting HP DDS
media.
Click here for
information on DDS

Additional
information

Action recommended

media label placement.


Click here for
information DDS media
care.
Click here for
information on ensuring
a long life for the HP
DAT product.
If the tape ejected, use the Read/Write test and the
Device Analysis test in L&TT with new media to check
that the drive is now working normally.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note
will be updated once the problem has been
corrected but until then do not use Library and
Tape Tools to diagnose issues with this
product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
If tape did not eject, see "Stuck Tape
Troubleshooting" for further troubleshooting help.

Click here for


information on HP
Library and Tape Tools.

See the "Stuck Tape


Troubleshooting"
section.

Back to Start of Section


Back to Top
Check if your media is ejecting after backup
Action recommended

Additional
information

If your media is ejecting after the back-up, check the


back-up application settings.
Run Device Analysis Test from Test drop down menu in HP
Library and Tape Tools (L&TT). Follow any troubleshooting
given with the test results.
NOTE:

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended

Due to issues in development Library and Tape


Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Installation/configuration issue
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.

Check tape drive and server compatibility.


Check server hardware compatibility.
Check host operating system (O/S) compatibility with server.
Check backup software to device compatibility.
Check driver is correct/loaded.
Check connectivity with Library and Tape Tools.
Check for Operating System or application issues.
HP Support contact details.

Installation/configuration troubleshooting details


Check tape drive and server compatibility
Action recommended

Additional information

Check the tape drive/server combination is


supported.

Click here to visit


www.hp.com/go/connect.

Check if an additional SCSI controller card,

Click here to visit

Action recommended

Additional information

power supply or fan module are required.

www.hp.com/go/connect.

Back to Start of Section


Back to Top
Check server hardware compatibility
Action recommended

Additional information

Check if the hardware installed in the


server (like PCI cards etc) is compatible
with that Server.

Click here to visit


www.hp.com/go/connect.
Click here for information on
hardware compatibility with servers.

Back to Start of Section


Back to Top
Check host operating system (O/S) compatibility with server
Action recommended

Additional information

Check that you have a supported


configuration and that the operating system
is supported on your server.

Click here for operating system


compatibility for pre-merger HP
Servers.
Click here for operating system
compatibility for pre-merger
Compaq Servers.

Back to Start of Section


Back to Top
Check backup software to device compatibility
Action recommended

Additional information

Check if the backup software is


compatible with the tape drive.

Click here for information on HP tape


backup products compatibility.

Back to Start of Section


Back to Top
Check driver is correct/loaded
Action recommended
Check driver is correct and
installed.
Back to Start of Section
Back to Top

Additional information
Click here for information on drivers and
operating systems.

Check connectivity with Library and Tape Tools


Additional
information

Action recommended
Check connectivity with HP Library and Tape Tools (L&TT).
Run Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Check for Operating System or application issues
Action recommended
Check for any other O/S or
application issues.

Additional information
See the Software/Application Issue
troubleshooting section.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Read/write issue
Try in the following order:

1.
2.
3.
4.
5.
6.

Run Device Analysis Test in Library and Tape Tools.


Run Read/Write test in Library and Tape Tools.
Test media using Media Validation Test in Library and Tape Tools.
Check the drive has been cleaned.
Upgrade to latest firmware.
HP Support contact details.

Read/write troubleshooting details


Run Device Analysis Test in Library and Tape Tools
Action recommended

Additional
information

Run the Device Analysis Test in HP Library and Tape Tools


(L&TT). Follow any troubleshooting given with the test
results.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Run Read/Write test in Library and Tape Tools
Action recommended

Additional
information

Run the Read/Write test in HP Library and Tape Tools


(L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not

Click here for


information on HP
Library and Tape
Tools.

Additional
information

Action recommended
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.
Back to Start of Section
Back to Top

Test media using Media Validation Test in Library and Tape Tools
Additional
information

Action recommended
Run the Media Validation Test in HP Library and Tape Tools
(L&TT).
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
Check that the drive has been cleaned
Action recommended
Insert a cleaning cartridge into the drive and
wait for the clean to take place. The tape is
ejected at the end.

Additional information
Click here for information on
clean light flashing on DAT
Drives.

Repeat the clean five times in total.


Check for expiry of cleaning tape.
Inspect your media and discard if faulty or
damaged. Check for the following:
o
o
o

Incorrect label placement


Damage
Usage in incorrect environment

Click here for information on


how to detect a damaged DDS
cartridge and what symptoms
would be seen.
Click here for information on

Action recommended

Additional information

Snapped/damaged tape

visually inspecting HP DDS


media.
Click here for information on
DDS media label placement.
Click here for information DDS
media care.
Click here for information on
ensuring a long life for the HP
DAT product.

Replace the data tape with a new tape, it may


be worn or at end of life.

Click here for information DDS


media care.

Introduce a regular clean into your backup


strategy

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Upgrade to latest firmware
Additional
information

Action recommended
Ensure your drive is running with the latest firmware.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Cleaning issues
Try in the following order:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Check you are using a compatible cleaning cartridge.


Check you are following the correct cleaning process.
Check if amber Clean LED is flashing.
Check if amber Clean LED is triggered regularly despite cleaning.
If DAT8/24/40, check if the cleaning tape is ejected quickly (less than 20 seconds) after
loading and the green Tape LED is FLASHING.
If DAT72, check if the cleaning tape is held by the drive for more than 2 minutes after
loading and the green Tape LED is FLASHING.
Check if the amber Clean LED is on constantly.
Run Library and Tape Tools Device Analysis Test (and recalibration script for DAT24 drives).
HP Support contact details.

Cleaning troubleshooting details


Check you are using a correct cleaning cartridge
Action recommended

Additional
information

Check you are using a HP DDS cleaning cartridge.


Clean the drive weekly by inserting a HP DDS cleaning tape.
This will keep the drive clean for maximum reliability. Do
not clean the DDS tape drive too often since this can reduce
the life expectancy of the tape drive.
NOTE:
An HP DDS cleaning cartridge will typically last for
50 cleaning cycles. In very occasional cases for
DAT72 and DAT40 though, the length of tape used
per clean may increase slightly, reducing the total
number of cleans available form the cleaning tape.
Back to Start of Section
Back to Top
Check you are following the correct cleaning process

Click here for


information DDS
media care.

Action recommended

Additional
information

Clean the drive weekly by inserting a HP DDS cleaning


tape. This will keep the drive clean for maximum
Click here for
information DDS media
reliability. Do not clean the DDS tape drive too often
since this can reduce the life expectancy of the tape
care.
drive.
Check for expiry of cleaning tape.
Click here for
information on how to
detect a damaged DDS
cartridge and what
symptoms would be
seen.

Inspect your media and discard if faulty or damaged.


Check for the following:
o
o
o
o

Incorrect label placement


Damage
Usage in incorrect environment
Snapped/damaged tape

Click here for


information on visually
inspecting HP DDS
media.
Click here for
information on DDS
media label placement.
Click here for
information DDS media
care.
Click here for
information on ensuring
a long life for the HP
DAT product.

Insert the cleaning cartridge into the drive and wait


for the clean to take place. The tape is ejected at the
end.

Click here for


information on the
clean light flashing on
DAT drives.
Click here for
information on the HP
DAT front panel LEDs.

If you have been experiencing problems with your


drive (read/write problems, performance problems,
etc) or you have not cleaned your drive for a while,
then repeat the clean five times in total.
Introduce a regular clean into your backup strategy.

Click here for


information on ensuring
a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check if amber Clean LED is flashing
Action recommended

Insert a cleaning cartridge into the drive and


wait for the clean to take place. The tape is
ejected at the end.

Additional information
Click here for information on the
clean light flashing on DAT
drives.
Click here for information on the
HP DAT front panel LEDs.

Repeat the clean five times in total.


Check for expiry of cleaning tape.
Introduce a regular clean into your backup
strategy.

Click here for information on


ensuring a long life for the HP
DAT product.

Back to Start of Section


Back to Top
Check if amber Clean LED is triggered regularly despite cleaning
Action recommended

Additional
information
Click here for
information on the
clean light flashing
on DAT drives.

Clean the drive five times.


Click here for
information on the
HP DAT front panel
LEDs.
Check for expiry of cleaning tape.

Check frequency of cleaning in backup strategy.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Check environmental conditions of drive and media


storage

Click here for


information DDS
media care.

Replace data tape with new tape, it may be worn or at


end of life.

Click here for


information DDS
media care.

Action recommended

Additional
information

If problems persist, run the Device Analysis Test in HP


Library and Tape Tools (L&TT). Follow any
troubleshooting given with the test results.
Ensure the latest firmware is loaded.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected
Back to Start of Section
Back to Top
If DAT8/24/40, check if the cleaning tape is ejected quickly after loading and the
green Tape LED is FLASHING
Action recommended

Additional
information
Click here for
information DDS
media care.

Check that the cleaning cartridge has been used less


that 50 times.

Try a new cleaning cartridge.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.

Click here for


information on the
HP DAT front panel
LEDs.
Click here for
information on
ensuring a long life
for the HP DAT
product.
Click here for
information on HP
Library and Tape
Tools.

Action recommended

Additional
information

NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected
Back to Start of Section
Back to Top
If DAT72, check if the cleaning tape is held by the drive for more than two minutes
after loading and the green Tape LED is FLASHING
Action recommended

Additional
information

Eject the cleaning tape using the Eject button (later


firmware will retain the cleaning tape, including premerger Compaq drives)

Click here for


information on the
HP DAT front panel
LEDs.

Check that the cleaning cartridge has been used less


than 50 times

Click here for


information DDS
media care.

Try a new cleaning cartridge.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose
potential issues with the DAT 40 Hotplug drive
(Q1546A only). This problem is currently being
investigated and will be corrected in the next

Click here for


information on HP
Library and Tape
Tools.

Action recommended

Additional
information

revision of Library and Tape tools. This note will


be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
Back to Start of Section
Back to Top
Check if the amber Clean LED is on constantly
Action recommended

Additional
information

REASON: The drive has experienced a hard failure.

Click here for


information on the
HP DAT front panel
LEDs.

Power cycle the drive to see if it recovers normally.

Click here for


information on
ensuring a long life
for the HP DAT
product.

Run the Device Analysis Test in HP Library and Tape


Tools (L&TT). Follow any troubleshooting given with the
test results.
Ensure the latest firmware is loaded.
NOTE:
Click here for
Due to issues in development Library and Tape
information on HP
Tools cannot be reliably used to diagnose
Library and Tape
potential issues with the DAT 40 Hotplug drive
Tools.
(Q1546A only). This problem is currently being
investigated and will be corrected in the next
revision of Library and Tape tools. This note will
be updated once the problem has been corrected
but until then do not use Library and Tape Tools
to diagnose issues with this product. This problem
only relates to the Q1546A product, no other DAT
40 variants are affected.
Back to Start of Section
Back to Top
Run Library and Tape Tools Device Analysis Test (and recalibration script for
DAT24 drives)

Additional
information

Action recommended
Run the Device Analysis Test in HP Library and Tape Tools
(L&TT). Follow any troubleshooting given with the test
results.
Run the recalibration script for DAT24 drives.
Ensure the latest firmware is loaded.
NOTE:
Due to issues in development Library and Tape
Tools cannot be reliably used to diagnose potential
issues with the DAT 40 Hotplug drive (Q1546A
only). This problem is currently being investigated
and will be corrected in the next revision of Library
and Tape tools. This note will be updated once the
problem has been corrected but until then do not
use Library and Tape Tools to diagnose issues with
this product. This problem only relates to the
Q1546A product, no other DAT 40 variants are
affected.

Click here for


information on HP
Library and Tape
Tools.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top

Broken/wrong/missing part issue


Try in the following order:
1. Information on part numbers.
2. HP Support contact details.

Broken/wrong/missing part troubleshooting


Information on part numbers
Action
recommended

Additional information

Action
recommended

Additional information

Information on part
numbers.

Click here for a matrix that cross references a drive's


product name, format, and part number.

Information on
compatibility.

Click here to visit www.hp.com/go/connect.

Back to Start of Section


Back to Top
HP Support contact details
Action
recommended

Additional information

Contact HP Support.

Click here for information on calling HP and other ways to


contact HP for technical support.

Back to Start of Section


Back to Top