KK-2

FORM U-DR-1 USERS DESIGN REQUIREMENTS FOR SINGLE CHAMBER PRESSURE VESSELS
Owner:
Service:

1
F

Operator:

2
F

Country of Installation:
3
F

4
F

5
F

Liquid Level:
Specific Gravity:
7
F

Diameter (in.):

10
F
National Board
Registration Required:
Yes
No

14
F

OPERATING CONDITIONS:

Minimum Pressure

6
F

9
Type: F
Vertical

12
F
Special Service:
Lethal (L)
Direct Firing (DF)
Unfired Steam Boiler (UB)

3
F

City of Installation:

Item No.:

8
F

Length, Tangent-to-Tangent:
11
F
Canadian
Registration Required:
Yes
No

State/Province of
3
F
Installation:

Horizontal

Sphere
13
F

Overpressure Protection:
Valve
Rupture Disk
Other
System Design

Minimum Temperature Maximum Temperature

Maximum Pressure

Case 1
Case 2
16
F

DESIGN CONDITIONS:
Internal Design Pressure:
External Design Pressure:

Pressure

17
F

MAWP Internal:
MAWP External:

Same as Design Pressure


Same as Design Pressure

Minimum Design Metal Temperature


(MDMT) Case 1
Minimum Design Metal Temperature
(MDMT) Case 2
Corrosion Allowance:
Shell

18
F

Heads

19
F

Int.
Cyclic Service: Yes
Wind Loading:
UBC
Other

No

ASCE 7
IBC
None

Int.

20
F
21
F

Int.

Due to:

Deg @

Due to:

Ext.

Cycles per
Wind Speed

Jacket
Int.

Lugs

Ext.

Int.

Design Life

Ext.

Thickness

years

Fatigue Analysis?

Exposure
Category

Topographic
Factor

Density

25
F

Coating Specification:

Saddles

26
F

Fireproofing:
Yes
No

Type:

28
MATERIALS F
Component

Hemispherical Head

Torispherical Head

Toriconical Head

Conical Head

Nozzles

Flanges

Stiffener Rings

Pressure Retaining Bolts

Attachments

Internals

Reinforcing Pads

Other
Flange
Type

NOZZLE SCHEDULE
Class
Description

07/10

669

27
F

Rating (hr):

Specification

Ellipsoidal Head

Size

No
Elevation

Permitted Prior to Pressure Test


Yes
No

Specification

Number
Required

Yes

23
F
Other Loadings per UG-22:
Temp. Gradients
Deflagration
Diff. Thermal Exp.

Shell

Description

Process
Other
Ambient Temperature

Process
Other
Ambient Temperature
Supports
Internals
Corrosive
Service?
Int.
Ext.
Yes
No

PWHT:
Per Code
Process Required

22
F

Type
External
Internal

Coil

Classification
Category

Soil Profile Classification:

24
F

Skirt

Deg @

Nozzles

Ext.

Calculated by Manufacturer:
Calculated by Manufacturer:

29
F

Number
Required

Size

Flange
Type

Class

This copy downloaded on 2015-07-13 07:03:53 -0500 by authorized user logan ahlstrom.

Insulated:
Yes
No
By Manufacturer
By Others

Component

Ext.

22
F

Seismic Loading: ASCE 7


UBC
IBC
Other
None

Vessel Support: Legs

Temperature

15