1604 Greens Road Houston, TX 77032

Phone:(281)590-6966
Fax:(281)590-2280

Revision: A

Document No.

NOV Adjustable Bend Housing


Field Adjustment Procedures

ADJHSGPNOV

Revision Date: April 23, 2012

Page 1 of 4

Contents
1. Preparations for Adjustment of ABH .......................................................................................1
2. Directions to Adjust ABH Angle ..............................................................................................2
3. Settings of Adjustable ABH Angle ..........................................................................................4
4. Make-up Torques ...................................................................................................................4

1. Preparations for Adjustment of ABH


Clean exterior of Adjustable Bend Housing before clamping, so markings are clearly visible.
Clamp indicated areas of Adjustable Bend Housing.
Untorque right hand connection (Figure 1).

UPHOLE
CLAMP THIS AREA

LOOSEN IN THIS
DIRECTION
BIT

CLAMP THIS AREA

Figure 1

1604 Greens Road Houston, TX 77032


Phone:(281)590-6966
Fax:(281)590-2280

NOV Adjustable Bend Housing


Field Adjustment Procedures
Revision Date: April 23, 2012

Revision: A

Document No.

ADJHSGPNOV
Page 2 of 4

2. Directions to Adjust ABH Angle


1. Unscrew Offset Housing 2 full rotations (Figure 2).
2. Lift the Adjusting Ring to disengage teeth from the Offset Housing (Figure 3).
3. Rotate Stator Adapter Housing in the direction that achieves the desired bend in the
shortest distance (Figure 4). See Table 1 for possible ABH bend angles.
WARNING: Never rotate housing more than turn in this step.

STATOR ADAPTER HOUSING

ADJUSTING
RING

Matched #s indicate angle


and scribe line location

Figure 2: Unscrew Offset


Housing 2 turns.

OFFSET HOUSING

Figure 3: Lift Adjusting Ring


and disengage teeth.

Figure 4: Rotate Stator Adapter


Housing to desired bend angle.

NOV Adjustable Bend Housing


Field Adjustment Procedures

1604 Greens Road Houston, TX 77032


Phone:(281)590-6966
Fax:(281)590-2280

Revision Date: April 23, 2012

Revision: A

Document No.

ADJHSGPNOV
Page 3 of 4

4. If needed, clean dirt and mud off of the housing faces and apply thread anti-seize
(Figure 5).
5. Ensure the desired bend angle on the Adjusting Ring is aligned with its matching
number on the Offset Housing, then engage the teeth and torque the connection
(Figure 6). See Table 2 for make-up torques.
STATOR ADAPTER HOUSING

ADJUSTING
RING

If needed, clean faces and apply


thread anti-seize to faces
torquing.

Figure 5

OFFSET HOUSING

Figure 6: Teeth engaged and connection


torqued.

Document No.

NOV Adjustable Bend Housing


Field Adjustment Procedures

1604 Greens Road Houston, TX 77032


Phone:(281)590-6966
Fax:(281)590-2280

ADJHSGPNOV

Revision Date: April 23, 2012

Revision: A

Page 4 of 4

3. Settings of Adjustable Bend Housing


ABH Bend Angles
3 DEGREE
4 DEGREE*
0.00
0.00
0.39
0.35
0.78
0.69
1.15
1.04
1.50
1.37
1.83
1.69
2.12
2.00
2.38
2.29
2.60
2.57
2.77
2.83
2.90
3.06
2.97
3.28
3.00
3.46
3.63
3.76
3.86
3.94
3.98
4.00
Table 1: ABH Bend Angles
* 4 Degree Adjustable Bend Housings available only for 3-3/4 & 4-3/4 motor sizes.

4. Make-up Torques
Ft-lbs
Nm

2-7/8
1,900
2,580

3-3/4
5,300
7,190

4-3/4
9,000
12,200

6-1/4
6-1/2 & 6-3/4
23,000
28,000
31,180
37,960
Table 2: ABH Make-up Torques

8
40,000
54,230

9-5/8
80,000
108,470

11-1/4
96,000
130,160

You might also like