Calculation of a bolted connection with prestress.

Loading by axial or
tangential force.
Input Parameters

Tightness factor

Fa

maximum opera

force input facto

Ft

maximum opera

joint friction fac

number of bolts

thread diameter

thread pitch

ds

mean bolt diame

d min

minimum bolt d

Sy

Yield strength

ks

safety factor (Th

pA

allowable thread

E1

elasticity modul

f1

thread friction fa

f2

friction factor in

width of connec

E2

elasticity modul

Calculation of Bolted Connection:

where:

c 1 = c 10 + (1 - n) c 20

c 2 = n c 20

for steel a = 10

Required tightening moment

Calculated tensile stress in the bolt

Calculated torsion stress in the bolt

Reduced stress in the bolt

Stress caused by maximum force loading the bolt

Calculated pressure in the thread

Calculation check - stress in the bolt during tightening the joint and during the operation
(respecting the specified joint safety), and the check of allowable pressure in threads.
red S y / k s and max S y / k s and p c p A

SUMMARY INPUT & RESULTS

Results

Prestress Force
Working Force
Required Tightening Moment
Tensile Stress
Torsional Stress
Reduced Stress
Stress from Maximum Force
Thread Pressure
Strength Check

Summary of Messages
Calculation indicates design compliance!

Fv
Fmax
Mu
t
k
red
max
pc

3420.435 N
3562.500 N
12.406 N m
39.755 MPa
55.109 MPa
103.400 MPa
41.407 MPa
19.273 MPa
Positive