Professional Documents
Culture Documents
Bolted Connection With Prestress
Bolted Connection With Prestress
Bolted Connection With Prestress
Loading by axial or
tangential force.
Input Parameters
Tightness factor
Fa
maximum opera
Ft
maximum opera
number of bolts
thread diameter
thread pitch
ds
d min
minimum bolt d
Sy
Yield strength
ks
pA
allowable thread
E1
elasticity modul
f1
thread friction fa
f2
friction factor in
width of connec
E2
elasticity modul
where:
c 1 = c 10 + (1 - n) c 20
c 2 = n c 20
for steel a = 10
Calculation check - stress in the bolt during tightening the joint and during the operation
(respecting the specified joint safety), and the check of allowable pressure in threads.
red S y / k s and max S y / k s and p c p A
Results
Prestress Force
Working Force
Required Tightening Moment
Tensile Stress
Torsional Stress
Reduced Stress
Stress from Maximum Force
Thread Pressure
Strength Check
Summary of Messages
Calculation indicates design compliance!
Fv
Fmax
Mu
t
k
red
max
pc
3420.435 N
3562.500 N
12.406 N m
39.755 MPa
55.109 MPa
103.400 MPa
41.407 MPa
19.273 MPa
Positive