Design the Two Storey Structure with Roofdeck using ETABS.
Design criteria: Design code: NSCP 2010, ACI318M-08 Compressive strength: 21MPa Yield Strength: Grade 40 Exterior wall: 6 CHB consider plaster Interior wall: 4 CHB consider plaster Interior and exterior wall: 21.2 kN/m^2 Plaster at both face: 0.48 kN/m^2 Maximum size of rebar to be used: 16mm Slab thickness: 125 mm Staircase thickness: 130 mm Ground to second floor: 3.8 m Second to roof: 3.5 m Parapet height: 1.3 m Door openings @ Visitor Lounge, T&Bs, Bedroom 2 and Bedroom 3: consider as interior wall. SDL: 3.0 kPa LL: 4.50 kPa C1: 300mm x 300mm; 4 16 mm dia. C2: 200mm x 300mm; 4 16 mm dia. C3: 250mm x 250mm; 4 16 mm dia. Minimum reinforcement ratio of columns is 1%; P = (As/Ag) Minimum spacing between parallel bars in a layer: db=bar diameter but not less than 25mm (ACI-318M-08) 1. 2. 3. 4. 5.
All structural elements must be ADEQUATE. (20pts.)
Show the longitudinal reinforcing of beams (Top and bottom area of steel). (10pts.) Show the longitudinal reinforcing of columns (C1, C2, C3) (Area of steel). (10pts.) Show the shear reinforcing of beams. (10pts) Provide the column details of all columns. Lateral ties spacing is 200mm. Use 2 legs at both directions. (10pts.)