Professional Documents
Culture Documents
Dieselec Iveco
Dieselec Iveco
Dieselec Iveco
IVECO
30-400 KVA
GENERATING SETS
Engine
Alternator
Tropical duty radiator with engine driven pusher fan and fan guards
Steel fabricated base frame with built in 4-8 hours capacity fuel bank
12/24 VDC electric starting and battery charging system
(200-1000KVA/50Hz are 24VDC) (438-1097KVA/60Hz are 24VDC)
Mechanical/electronic speed governor Class A
(200-1000KVA/50Hz are electronic) (250-1097KVA/60Hz are electronic)
Anti vibration mounting between engine / alternator and base frame
Fuel oil and air filters
Industrial exhaust muffler with flexible section
Set mounted duly rated circuit breaker
Engine and alternators instruction manuals
Control panel
150 KVA (50Hz), 188 KVA (60Hz)
o Set mounted Auto/Manual start panel with metering for voltage, current frequency, oil pressure, water
temperature battery charging indicator light, hours counter.
o Engine Shutdown protection are available for low oil pressure, high water temperature, engine
over speed and battery charging system failure
200 to 460 KVA
o Set Mounted Auto/Manual start digital / programmable control panel using Deepsea 5310 or equivalent
J1939 enabled controller communicating directly with engine ECU complete with meterings for voltage,
current, frequency, KW, KVA, powerfactor, oil pressure, water temperature, rpm, DC voltage, hours
counter.
o Engine shutdown protection are available for low oil pressure high water temperature, under and
over speed (or frequency) under and over AC voltage, low battery voltage, charging system failure
and over current.
Standard
Accessories
Soundproof Enclosure
The Soundproof enclosures are fabricated from cold rolled steel and powder paint finished to
Optional
Accessories
standard manufacturers colors. The sound level is 85 dba at 1 meter in free field condition.
Soundproof gensets are supplied with residential exhaust silencers. Each enclosure have large
lockable side doors for easy access to the generator. The genset control panel is accessible via a
glass door at the alternator end of the enclosure.
Other Options
Check with the factory for other available options including super silent enclosures, Automatic
Transfer Switches, synchronizing systems, trailers, electronic governors, engine heaters,
anticondensation heaters, special alarms, free standing fuel tanks, remote cooling systems, special
AVRs, medium voltages and others as customers may require.
Genset Model
DI 30
DI 40
DI 45
DI 50
DI 60
DI 75
DI 85
DI 100
DI 125
DI 130
DI 160
DI 200
DI 250
DI 300
DI 350
DI 400
Genset Model
DI 40
DI 58
DI 75
DI 83
DI 110
DI 125
DI 160
DI 188
DI 250
DI 300
DI 350
DI 420
DI 460
Fuel Consumption at
Full Load Li/Hr
6.7
8.9
10.35
11.1
13.52
16.97
19.11
21.82
28.50
29.6
30.31
42.97
50.55
62.73
69.46
80.91
Fuel Consumption at
Full Load Li/Hr
8.76
12.94
16.70
19.41
25.41
28.70
36.98
43.91
55.06
63.24
76.40
89.86
107.45