Saigonnewtech01 - System Family

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

The SIMATIC S7 System Family

SIMATIC
PCS 7
SIMATIC
NET

SIMATIC
Software

SIMATIC
PC

SIMATIC
HMI

SIMATIC
SIMATIC
WinCC

SIMATIC
DP
SIMATIC
Controller

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.1

SITRAIN Training for


Automation and Drives

Objectives

Upon completion of this chapter the participant will ...


...

have an overview of the SIMATIC S7 system family

...

be familiar with the S7-200 and S7-300/400 automation


systems

...

have an overview of the modules available for these automation


systems

...

understand the concept of "Totally Integrated Automation"

...

be familiar with the SIMATIC programming devices and the PC


requirements for working with STEP7

...

be familiar with the tools of the STEP7 basic programming package

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.2

SITRAIN Training for


Automation and Drives

SIMATIC Overview
SIMATIC PG
SIMATIC PC

SIMATIC HMI

SIEMENS

S IM A T IC O P 1 7

PG 740

K1

K2

K3

K4

K5

K6

K7

K8

K9

K10

K 11

K 12

K13

K 14

K 15

K16

H E LP
S H IF T

E S C

8
D

AC K

6
B

9
E

5
A

S H IF T

IN S
DE L

H E L P

E NT ER

MPI Network
Industrial Ethernet

SIMATIC NET
SIMATIC NET

PROFIBUS

SIMATIC
Controller
SIEMENS

SF
RUN
STOP

I0.0
I0.1
I0.2
I0.3
I0.4
I0.5

Q0.0
Q0.1
Q0.2
Q0.3
Q0.4

CPU 212

Q0.5

I0.6
I0.7

SIMATIC
S7-200

PROFIBUS-DP

SIMATIC DP

FM

ASI

SV

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.3

SITRAIN Training for


Automation and Drives

S7-200

S7-22x

S7-21x (earlier)

EM 221

SIEMENS

SF
RUN
STOP

I0.0
I0.1
I0.2
I0.3
I0.4

I1.0
I1.1
I1.2
I1.3
I1.4

I0.5
I0.6
I0.7

I1.5

Q0.0
Q0.1
Q0.2
Q0.3
Q0.4
Q0.5
Q0.6
Q0.7

Q1.0
Q1.1

CPU 214
I.1
I.2
I.3
I.4
I.5
I.6

SIMATIC
S7-200

SIMATIC S7
Siemens AG 2002. All rights reserved.

DI 8 x DC24V
I.0

I.7

Date:
File:

25.06.2006
PRO1_01e.4

SITRAIN Training for


Automation and Drives

S7-200: Modules S7-21x series

CP242 - 2

EM

SIMATIC S7
Siemens AG 2002. All rights reserved.

EM

Date:
File:

25.06.2006
PRO1_01e.5

CP

SITRAIN Training for


Automation and Drives

S7-200: Modules S7-22x series

EM

SIMATIC S7
Siemens AG 2002. All rights reserved.

EM

Date:
File:

25.06.2006
PRO1_01e.6

CP

SITRAIN Training for


Automation and Drives

S7-200: CPU Design S7-21x Series

Outputs
Memory Card

Mode Selector

Potentiometer
SIEMENS

SF
RUN
STOP

I0.0
I0.1
I0.2
I0.3
I0.4
I0.5

Q0.0
Q0.1
Q0.2
Q0.3
Q0.4

CPU 212

Q0.5

I0.6
I0.7

SIMATIC
S7-200

PPI Connection

Inputs

SIMATIC S7
Siemens AG 2002. All rights reserved.

Status Indicators

Status Indicators
for Integrated DI/DO

Date:
File:

25.06.2006
PRO1_01e.7

SITRAIN Training for


Automation and Drives

S7-200: CPU Design S7-22x Series


Outputs

Status Indicators
Memory Card
Front access door
Mode Selector
Potentiometer
I/O Expansion

PPI Connection

Status Indicators
for Integrated DI/DO

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.8

Inputs

SITRAIN Training for


Automation and Drives

S7-300

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.9

SITRAIN Training for


Automation and Drives

S7-300: Modules

PS
(optional)

CPU

SIMATIC S7
Siemens AG 2002. All rights reserved.

IM
SM:
(optional) DI

SM:
DO

Date:
File:

SM:
AI

25.06.2006
PRO1_01e.10

SM:
AO

FM:
- Counting
- Positioning
- Closed-loop
control

CP:
- Point-to-Point
- PROFIBUS
- Industrial Ethernet

SITRAIN Training for


Automation and Drives

S7-300: CPU Design

SIEMENS

CPU314

SIEMENS

CPU315-2 DP

SF
BATF
DC5V
FRCE
RUN
STOP

SF
BATF
DC5V
FRCE
RUN
STOP

RUN-P

RUN-P

RUN

RUN

STOP

STOP

M RES

M RES

SIMATIC
S7-300
Batterie

SIMATIC S7
Siemens AG 2002. All rights reserved.

SF DP
BUSF

SIMATIC
S7-300
Batterie

MPI

Date:
File:

25.06.2006
PRO1_01e.11

MPI

DP

SITRAIN Training for


Automation and Drives

S7-400

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.12

SITRAIN Training for


Automation and Drives

S7-400: Modules

PS

CPU

SIMATIC S7
Siemens AG 2002. All rights reserved.

SM:
DI

SM:
DO

SM:
AI

SM:
AO

Date:
File:

CP

25.06.2006
PRO1_01e.13

FM

SM

IM

SITRAIN Training for


Automation and Drives

S7-400: CPU Design

Fault LEDs
Slot for Memory
Card
Mode Selector
MPI/DP
Interface
DP Interface

External Battery
Supply

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.14

SITRAIN Training for


Automation and Drives

Programming Devices

Field PG

Power PG

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.15

SITRAIN Training for


Automation and Drives

PG/PC Requirements for Installing STEP 7


Operating system:

Windows (all, except Win 3.1 and 3.11)


95/98

ME

NT

2000

Processor

>= 80486

>= P150

>= Pentium

>= P233

RAM

>= 32 MB

>= 64 MB

>= 32 MB

>= 128 MB

Memory on the
Hard Drive:

depending on the installation, between 200 MB and 380 MB


plus 128 to 256 MB minus the working memory for
Windows Swap File

Mouse:

yes

Interfaces:

CP5611 (PCI) or
CP5511 (PCMCIA) or
PC adapter
Programming interface for Memory Card (optional)

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.16

SITRAIN Training for


Automation and Drives

Installing STEP 7 Software

SIEMENS

PG 740

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.17

SITRAIN Training for


Automation and Drives

Result of Installation
Double-click on icon

Activate through Start menu

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.18

SITRAIN Training for


Automation and Drives

STEP 7 Tools

SIMATIC S7
Siemens AG 2002. All rights reserved.

Date:
File:

25.06.2006
PRO1_01e.19

SITRAIN Training for


Automation and Drives

You might also like