Professional Documents
Culture Documents
Ps21867 P Original
Ps21867 P Original
Ps21867 P Original
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Intellimod Module
Dual-In-Line Intelligent
Power Module
30 Amperes/600 Volts
A
M
J
BB
P
27
1
28
2
30
4 29
31
6
33
8 32
9 10 11
35
12 13 34
14 15 16 17 18 19 20
38
39
LABEL
41
40
22
23
24
36
37
AA
B
HEATSINK
SIDE
21
25
26
X
E
CC
CC
K
Q (2 PLACES)
0-5 MAX.
V
W
T
45.0
U
DD
TERMINAL CODE
1 UP
2 VP1
8 VVFS
15 VNC
22 P
29 NC
36 NC
9 WP
10 VP1
16 CIN
17 CFO
30 NC
31 NC
32 NC
37 NC
38 NC
39 NC
40 NC
41 NC
4 VUFS
5 VP
11 VPC
12 VWFB
18 FO
23 U
24 V
25 W
6 VP1
13 VWFS
19 UN
20 VN
26 N
27 NC
33 NC
34 NC
7 VVFB
14 VN1
21 WN
28 NC
35 NC
3 VUFB
Features:
Compact Packages
Single Power Supply
Integrated HVICs
Direct Connection to CPU
Inches
3.110.02
1.220.02
0.280.02
2.640.01
0.530.02
0.840.02
1.370.02
0.150.01
Millimeters
79.00.5
31.00.5
7.00.5
67.00.3
13.40.5
21.40.5
34.90.5
3.80.2
J
K
L
M
N
P
0.110.01
0.390.01
0.790.01
0.500.04
2.98
0.04
2.80.3
10.00.3
20.00.3
12.81.0
75.6
1.0
Dimensions
Inches
Millimeters
Q
0.180.01 Dia. 4.50.2 Dia.
R
0.070.002
1.90.05
S
0.040.01
1.00.2
T
0.02 Max.
0.5 Max.
U
0.060.02
1.60.5
V
0.070.002
1.700.05
W
0.030.01
0.80.2
X
0.450.02
11.50.5
Y
Z
AA
BB
CC
DD
0.13 Max.
0.03
0.18
0.12
0.02
0.07 Max.
Description:
DIP-IPMs are intelligent power
modules that integrate power
devices, drivers, and protection
circuitry in an ultra compact
dual-in-line transfer-mold package
for use in driving small three
phase motors. Use of 5th
generation IGBTs, DIP packaging,
and application specic HVICs
allow the designer to reduce
inverter size and overall design
time.
3.25 Max.
0.7
4.5
3.1
0.6
1.85 Max.
Applications:
Washing Machines
Refrigerators
Air Conditioners
Small Servo Motors
Small Motor Control
Ordering Information:
PS21867-P is a 600V, 30 Ampere
DIP Intelligent Power Module.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21867-P
Intellimod Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
Symbol
PS21867-P
Units
Tj
-20 to 125
Tf
-20 to 100
Tstg
-40 to 125
13
in-lb
65
Grams
VCC(prot.)
400
Volts
VISO
2500
Volts
Storage Temperature
*The maximum junction temperature rating of the power chips integrated within the DIP-IPM is 150C (@Tf 100C). However, to ensure safe operation of the DIP-IPM,
the average junction temperature should be limited to Tj(avg) 125C (@Tf 100C).
**VD = 13.5 ~ 16.5V, Inverter Part, Tj = 125C, Non-repetitive, Less than 2s
VCES
600
Volts
IC
30
Amperes
ICP
60
Amperes
VCC
450
Volts
VCC(surge)
500
Volts
PC
60.6
Watts
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)
Supply Voltage (Applied between VUFB-VUFS, VVFB-VVFS, VWFB-VWFS)
VD
20
Volts
VDB
20
Volts
Input Voltage (Applied between UP, VP, WP-VPC, UN, VN, WN-VNC)
VIN
-0.5 ~ VD+0.5
Volts
VFO
-0.5 ~ VD+0.5
Volts
IFO
mA
VSC
-0.5 ~ VD+0.5
Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21867-P
Intellimod Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
Symbol
Test Conditions
Min.
Typ.
Max.
Units
ICES
1.0
mA
10
mA
VEC
1.5
2.0
Volts
VCE(sat)
1.6
2.1
Volts
ton
1.7
2.2
Volts
0.7
1.30
1.90
trr
0.30
tC(on)
0.40
0.60
toff
1.70
2.40
0.50
0.80
tC(off)
Tf Measurement Point
IGBT CHIP
DIP-IPM
CONTROL TERMINALS
GROOVE
Al BOARD
18mm
13.5mm
P
U
V
W
POWER TERMINALS
FWDi CHIP
TEMPERATURE
MEASUREMENT POINT
(INSIDE THE Al BOARD)
TEMPERATURE
MEASUREMENT POINT
(INSIDE THE Al BOARD)
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21867-P
Intellimod Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Supply Voltage
VD
13.5
15.0
16.5
Volts
VDB
13.0
15.0
18.5
Volts
ID
5.00
mA
7.00
mA
0.40
mA
0.55
mA
4.9
Volts
VVFB-VVFS, VWFB-VWFS
Circuit Current
VFOH
VFOL
0.95
Volts
IIN
VIN = 5V
1.0
1.50
2.00
mA
VSC(ref)
Tj = 25C, VD = 15V
0.43
0.48
0.53
Volts
UVDBt
10.0
12.0
Volts
Protection
UVDBr
10.5
12.5
Volts
UVDt
10.3
12.5
Volts
UVDr
10.8
13.0
Volts
tFO
CFO = 22nF
1.0
1.8
ms
ON Threshold Voltage
Vth(on)
2.1
2.3
2.6
Volts
Vth(off)
0.8
1.4
2.1
Volts
Symbol
Condition
Min.
Typ.
Max.
Units
Thermal Characteristics
Characteristic
Junction to Fin
Rth(j-f)Q
1.65
C/Watt
Thermal Resistance
Rth(j-f)D
3.00
C/Watt
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 51A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width tFO depends on the capacitance value
of CFO according to the following approximate equation: CFO = (12.2 x 10-6) x tFO {F} .
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21867-P
Intellimod Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
Symbol
Supply Voltage
Control Supply Voltage
Condition
Min.
Typ.
Value
Units
300
400
Volts
VCC
VD
13.5
15.0
16.5
Volts
VDB
13.0
15.0
18.5
Volts
-1
V/s
VVFB-VVFS, VWFB-VWFS
Control Supply Variation
VD, VDB
fPWM
Tf 100C, Tj 125C
kHz
IO
18.9
Arms
11.6
Arms
PWIN
ON / OFF
300
ns
VNC
-5.0
5.0
Volts
tDEAD
2.0
* The allowable rms current value depends on the actual application conditions.
**The input pulse width less than PWIN might make no response.
2.5
2.0
1.5
1.0
0.5
0
15
30
45
60
VIN = 0V
Tj = 25C
Tj = 125C
2.0
1.5
1.0
0.5
0
15
30
45
60
102
VCC = 300V
VD = VDB = 15V
VIN = 0V 5V
Tj = 25C
Tj = 125C
101
100
100
101
101
SWITCHING LOSS, ESW(on), (mJ/PULSE)
103
REVERSE RECOVERY TIME, trr, (ns)
2.5
VD = VDB = 15V
VIN = 5V
Tj = 25C
Tj = 125C
102
VCC = 300V
VD = VDB = 15V
VIN = 0V 5V
Tj = 25C
Tj = 125C
101
100
101
EMITTER CURRENT, IE, (AMPERES)
102
101
VCC = 300V
VD = VDB = 15V
VIN = 0V 5V
Tj = 25C
Tj = 125C
COLLECTOR-EMITTER
SATURATION VOLTAGE, VCE(sat), (VOLTS)
3.0
FREE-WHEEL DIODE
FORWARD CHARACTERISTICS
(TYPICAL)
EMITTER-COLLECTOR VOLTAGE, VEC, (VOLTS)
COLLECTOR-EMITTER
SATURATION VOLTAGE CHARACTERISTICS
(TYPICAL)
100
10-1
100
101
COLLECTOR CURRENT, IC, (AMPERES)
102
102
VCC = 300V
VD = VDB = 15V
VIN = 0V 5V
Tj = 25C
Tj = 125C
100
10-1
100
101
COLLECTOR CURRENT, IC, (AMPERES)
102
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21867-P
Intellimod Module
Dual-In-Line Intelligent Power Module
30 Amperes/600 Volts
DIP-IPM Application Circuit (Shown Pins Up)
+3.3 to +5V
+15V
RSF
CSF
RSHUNT
WN
VN
INPUT SIGNAL
CONDITIONING
UN
FAULT
LOGIC
C5 x 3
C3
CIN
C4
VNC
C2
UV
PROT.
VN1
VWFS
C1
D1
VWFB
VP1
VP
C5
C1
R1
C2
D1
R2
C2
VUFS
+VCC
GATE DRIVE
UV PROT.
C2
R2
MOTOR
V
VUFB
VP1
UP
HVIC
C5
+VCC
GATE DRIVE
UV PROT.
D1
VVFS
VVFB
LEVEL SHIFT
C2
LEVEL SHIFT
INPUT
CONDITION
C1
+VCC
GATE DRIVE
UV PROT.
WP
C5
LEVEL SHIFT
VP1
INPUT
CONDITION
C2
INPUT
CONDITION
VPC
R2
R1
HVIC
R1
C2
HVIC
CONTROLLER
+VCC LVIC
OVER CURRENT
PROTECTION
FO
CFO
N
GATE DRIVE
R3
R2 x 3
AC LINE
C7
C6
+
Component Selection:
Dsgn.
Typ. Value
Description
D1
C1
1A, 600V
10-100uF, 50V
Boot strap supply reservoir Electrolytic, long life, low Impedance, 105C (Note 5)
C2
C3
0.22-2.0uF, 50V
10-100uF, 50V
Control power supply filter Electrolytic, long life, low Impedance, 105C
C4
C5
22nF, 50V
100pF, 50V
C6
C7
200-2000uF, 450V
Main DC bus filter capacitor Electrolytic, long life, high ripple current, 105C
0.1-0.22uF, 450V
CSF
RSF
1000pF, 50V
1.8k ohm
RSHUNT
R1
5-100 mohm
Current sensing resistor - Non-inductive, temperature stable, tight tolerance (Note 10)
10 ohm
R2
R3
330 ohm
10k ohm
Notes:
1) To prevent input signal oscillations minimize wiring length to controller (~2cm). Additional RC filtering (C5 etc.) may be
required. If filtering is added be careful to maintain proper dead time. See application notes for details.
2) Internal HVIC provides high voltage level shifting allowing direct connection of all six driving signals to the controller.
3) FO output is an open collector type. Pull up resistor (R3) should be adjusted to current sink capability of the module.
4) C4 sets the fault output duration and lock-out time. C4 12.2E-6 x tFO, 22nF gives ~1.8ms
5) Boot strap supply component values must be adjusted depending on the PWM frequency and technique.
6) Wiring length associated with RSHUNT, RSF, CSF must be minimized to avoid improper operation of the SC function.
7) RSF, CSF set short-circuit protection trip time. Recommend time constant is 1.5us-2.0us. See application notes.
8) Local decoupling/high frequency filter capacitors must be connected as close as possible to the modules pins.
9) The length of the DC link wiring between C6, C7, the DIPs P terminal and the shunt must be minimized to prevent
excessive transient voltages. In particular C7 should be mounted as close to the DIP as possible.
10) Use high quality, tight tolorance current sensing resistor. Connect resistor as close as possible to the DIPs
N terminal. Be careful to check for proper power rating. See application notes for calculation of resistance value.