Professional Documents
Culture Documents
Kral Bem 2u
Kral Bem 2u
2. Connect sensor:
max. 3 terminals
3. Connect power:
stand-alone (battery
included) or loop-powered
(2 terminals)
4. Read display:
Multiple Mounting
Options
Functional Signal
Transmission
Performance characteristics*
Display
LCD 90 x 40 mm
Buttons
3 robust micro-switches
Measured values
Units
Signal outputs
Power supply
stand-alone: battery operation (life span 7 years) or loop-powered: max. 30 VDC or 24 VAC
Environment
Mounting
Decision Aid
Advantages of the BEM 20.01:
connected with the BEG 45 coil sensor no external
power supply is required (battery operation)
the device can also be programmed when
unplugged
* The performance characteristics depend on the device type. For more detailed information, see the selection part of this
brochure on page 8.
For more information about our precision flowmeters please request our product brochures from your local representative
or visit us at www.kral.at
The Solution
The BEM 2U - Easiest Operation and
Informative Measured Value Display
Trend Indication
Battery Warning
Operating Mode
TOTAL
) indicate
The arrows (
increasing or decreasing
flow. The trend display
can point out process
changes which otherwise
would only be recognized
later.
RATE
Informative Measured
Value Display With Units
All total and flowrate
values are displayed
unmistakably with their
corresponding units. The
required units can be
selected in the program
mode.
Volumeter Mounting
with Plate and Strap
Connection
BEM 20.01
BEM 21.01
In addition, if NAMUR or
PNP sensors are being
used, the BEM 2U is
supplied with voltage via
the terminals (4,5).
Pre-programmed - Ready
for Immediate use
The BEM 2U is delivered
pre-programmed. After
powering on, the standard
display appears. The
BEM 2U is immediately
ready for operation and
displays TOTAL and RATE.
Start Up
Specifications
Description
BEM 20.01
BEM 21.01
internal lithium
battery, 3,2 VDC
8 to 28 VAC or
10-30 VDC/100 mA
Power supply
Environment
Operating temperature
Storage temperature
max. humidity
EMC
20 to +70 C
30 to +80 C
90%
EN 50081 and EN 50082
Mounting
Wright
Sensor type
Sensor supply Ub
Switching threshold
Sensitivity (coil)
Uss >= 2 mV
otherwise: 1,2 VDC
Input impedance
coil: infinite
Namur: 820
NPN, PNP: 100 k
< 0,1%
max. 10 kHz
Dimensions
System of protection
Material
Sensor
Flowrate accuracy
Frequency
Operation and electronics Display
Keys
Memory
Analog output *
Pulse output
Range
Accuracy
Resolution
Response time (for 90%)
Working resistance
4 to 20 mA
<0,1%
10 bit
0,1 to 23 s ( adjustable)
<250
Frequency
Pulse duration
High level
Signal output
Working resistance
max. 64 Hz
7,8 to 1992 ms (adjustable)
supply voltage
= max. 30 VDC
>1 k
100 000
10 000
1000
200
100
Viscosity [mm2/s]
short-term operation
continuous operation
0,1 %
20
10
5
1
0,3 %
accuracy 0,1%
1,0 %
0,3 %
1
1 10
50
100
150
Flowrate [% of Qnenn]
Laboratory measuring
accuracy is possible with
KRAL Volumeters even
under rough operating
conditions. The KRAL
BEM 2U local display
adheres to this objective
and displays the measured
values of the Volumeters.
You can feel the robust
design of the display
when you hold it in your
hands. The housing is
manufactured from cast
aluminum, has a UV-resistant coating and complies
with the IP67 protection
class (IP65 for panel
mount).
We are a manufacturer of
high-precision flowmeters.
KRAL Volumeters have an
excellent international
reputation. We know the
requirements for flow
measurement from our
own experience.
enderwerbung.com
Krutler GmbH & Co., Bildgasse 40, A-6893 Lustenau, Austria, Telephone: +43 / (0) 55 77 / 8 66 44-0, Telefax: +43 / (0) 55 77 / 8 84 33
www.kral.at, E-mail: kral@kral.at