Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

KRAL Volumeter

BEM 2U Local Display

KRAL Volumeter - BEM 2U Local Display

The Informative and Robust Local


Display From KRAL

The Fast way to the Measuring Result


1. Mount BEM 2U:

panel, flowmeter, wall


or pipe mounting

2. Connect sensor:

max. 3 terminals

3. Connect power:

stand-alone (battery
included) or loop-powered
(2 terminals)

4. Read display:

2 line display with total


and flowrate

Good Reasons for a


Local Display

Informative Display Easy Operation

The display of the measuring result is often


required directly at the
flowmeter:
the flow measurement
is installed on a machine and the data is
maintained locally
a remote computer is
not available. The
process data will be
displayed at the point
of measurement
despite recording and
display of the measurement value in the
control room, information
is required at the point
of measurement

Local displays increase


the process safety, because they give the reading
directly at the point of
measurement. The measured values must be able
to be read without error.
In many displays, missing
units or confusing characters can cause reading
errors.

The KRAL BEM 2U offers


many mounting options
close to the Volumeter.
Sensor connection and
power supply are carried
out by max. 5 connection
terminals. Once started,
total and flowrate are
displayed continuously.

On a clear display, the


KRAL BEM 2U shows the
total and flowrate values.
Each value is displayed
with its corresponding
unit. This eliminates
errors. We also program
the BEM 2U individually
according to the customers specifications.
The password protected
settings can be changed
using only three keys.

Multiple Mounting
Options

At any location with several measuring devices,


the danger of a measured
value being incorrectly
allocated exists. If a local
display is required, it
should be close to the
point of measurement. In
many cases, there is no
convenient mounting
location and the available
space is limited.
The KRAL BEM 2U is
supplied with 2 mounting
elements. This allows for
IP65 control panel mounting or IP67 flowmeter,
wall and pipe mounting.

Functional Signal
Transmission

For further evaluation,


display, and control the
measured values can be
transmitted to remote
systems. The local display
has this option.
BEM 2U signals with
external power supply:
pulse output, used to
transmit pulses scaled
to a convenient measurement amount
analog output 4 to
20 mA, scalable to a
convenient flowrate
range

Performance characteristics*
Display

LCD 90 x 40 mm

Buttons

3 robust micro-switches

Measured values

total, flow rate, accumulated total (by pressing a key)

Units

volume: ml, l, m3, gallon; mass: mg, g, kg, metric ton, lb

Signal outputs

scalable 4 to 20 mA analog output, scalable pulse output

Power supply

stand-alone: battery operation (life span 7 years) or loop-powered: max. 30 VDC or 24 VAC

Environment

protection class IP67, robust aluminum housing; operating temperature - 20 to +70 C

Mounting

panel, flowmeter, wall or pipe mounting

Decision Aid
Advantages of the BEM 20.01:
connected with the BEG 45 coil sensor no external
power supply is required (battery operation)
the device can also be programmed when
unplugged

Advantages of the BEM 21.01:


the device has outputs for signal transmission
the display is updated faster, because there is no
battery with life span needing to be considered
the power supply for the sensor can be adjusted

* The performance characteristics depend on the device type. For more detailed information, see the selection part of this
brochure on page 8.
For more information about our precision flowmeters please request our product brochures from your local representative
or visit us at www.kral.at

The Solution
The BEM 2U - Easiest Operation and
Informative Measured Value Display

Trend Indication

Battery Warning

Operating Mode

TOTAL

) indicate
The arrows (
increasing or decreasing
flow. The trend display
can point out process
changes which otherwise
would only be recognized
later.

Appears, when the


power supply falls below
the minimum admissible
value. After the warning
you have three days to
change the battery.

The BEM 2U keeps you


continuously informed of
the operating mode. The
measuring mode is the
default mode and is
displayed with RUN.

The total with the unit is


displayed clearly in the
main line.

Easy Control With


Only 3 Keys

Housing for Roughest


Operating Conditions

RATE

Settings can be made


with a password by using
only three keys.

The BEM 2U is delivered


with a robust IP67 protection class aluminum
housing.

The flowrate with the unit


is displayed in the bottom
of the display field.

Informative Measured
Value Display With Units
All total and flowrate
values are displayed
unmistakably with their
corresponding units. The
required units can be
selected in the program
mode.

BEM 2U with 6 Mounting Options

1 Mounting Plate + 1 Mounting Strap = 6 Mounting Options


The mounting elements are included.

Panel Mounting without


Mounting Plate

Wall Mounting with


Mounting Plate

Volumeter Mounting
with Plate and Strap

Pipe Mounting with


Plate and Strap

The BEM 2U is prepared


for panel mounting according to IP65.

Using the mounting


plate, the BEM 2U can
be mounted on a wall.
IP67 protection class.

For mounting directly on


the KRAL Volumeter, the
mounting plate and
mounting strap are used.
IP67 protection class.

The two mounting


elements allow for easy
mounting on horizontal
and vertical pipes. IP67
protection class.

Connection

Back of BEM 20.01

Back of BEM 21.01

BEM 20.01

BEM 21.01

With the KRAL BEM 20.01,


during battery operation
you only need to connect
the sensor via the terminals (1,2,3).

With the KRAL BEM 21.01,


the sensor cable is attached to terminals (9, 10,
11), the voltage supply to
terminals ( ,1,2) and the
signal outputs to terminals
(5-8), if required.

In addition, if NAMUR or
PNP sensors are being
used, the BEM 2U is
supplied with voltage via
the terminals (4,5).

Pre-programmed - Ready
for Immediate use
The BEM 2U is delivered
pre-programmed. After
powering on, the standard
display appears. The
BEM 2U is immediately
ready for operation and
displays TOTAL and RATE.

Changing the BEM 2U Configuration Using "Unit" as an Example

Step 2 - Changing the Setting

The settings can be changed quickly. After entering the


password, you reach the setup mode. The BEM 2U
informs you by displaying SETUP.

Use the arrow keys to navigate within the menu. Use


the
key to change the main menu, use the key to
navigate within the main menu. Example: 21 means:
main menu 2 "Flowrate", sub-menu 21 "Unit". Here you
can set the unit of the flowrate.

Step 1 - Entering the Password

BEM 2U - Device Selection

Start Up

BEM 2U - Device Selection

Specifications
Description

BEM 20.01

BEM 21.01

one channel *, rate/total,


battery operation,
two resettable totals

one channel *, rate/total,


two resettable totals,
active analog output
4 to 20 mA, active
pulse output

internal lithium
battery, 3,2 VDC

8 to 28 VAC or
10-30 VDC/100 mA

*) optional two channels - for example for differencial measurement

Power supply

Environment

Operating temperature
Storage temperature
max. humidity
EMC

20 to +70 C
30 to +80 C
90%
EN 50081 and EN 50082

same as BEM 20.01

Housing & connection

Mounting

same as BEM 20.01

Wright

Wall or surface mount or


integration
130x114x58 mm (WxHxD)
IP67 wall and surface
mount; IP65 integration
Aluminum, UV-resistant
coating
1,2 kg

Sensor type
Sensor supply Ub

Coil, NPN, PNP, Namur


none/external

Switching threshold
Sensitivity (coil)

Uss >= 2 mV
otherwise: 1,2 VDC

Input impedance

coil: infinite
Namur: 820
NPN, PNP: 100 k
< 0,1%
max. 10 kHz

same as BEM 20.01


8,1/12/24 VDC
max. 50 mA
Uss >= 2 mV
if dC is selected: Ub/2;
otherwise same as BEM 20.01
if dC is selected: 3 k
otherwise same as BEM 20.01

Dimensions
System of protection
Material

Sensor

Flowrate accuracy
Frequency
Operation and electronics Display

LCD 90x40 mm;


same as BEM 20.01
17 mm / 8 mm
numeric / alphanumeric
3 keys (robust micro-switches)
EEPROM 8 k / 10 years durable

Keys
Memory
Analog output *

*) optional 1 or 2 analog inputs for example for temperature


compensation

Pulse output

same as BEM 20.01


same as BEM 20.01

Range
Accuracy
Resolution
Response time (for 90%)
Working resistance

4 to 20 mA
<0,1%
10 bit
0,1 to 23 s ( adjustable)
<250

Frequency
Pulse duration
High level
Signal output
Working resistance

max. 64 Hz
7,8 to 1992 ms (adjustable)
supply voltage
= max. 30 VDC
>1 k

100 000
10 000
1000
200
100

Viscosity [mm2/s]

Reasons for the Right Decision

Precise Flow Measurement in Practice

short-term operation

continuous operation

0,1 %

20
10
5
1

0,3 %

accuracy 0,1%

1,0 %

0,3 %

1
1 10

50

100
150
Flowrate [% of Qnenn]

Possible Applications for


the KRAL BEM 2U

KRAL Complete Solution


for Oil Burners

High Accuracy and Wide


Range

KRAL Precision Flow


Measurement

Laboratory measuring
accuracy is possible with
KRAL Volumeters even
under rough operating
conditions. The KRAL
BEM 2U local display
adheres to this objective
and displays the measured
values of the Volumeters.
You can feel the robust
design of the display
when you hold it in your
hands. The housing is
manufactured from cast
aluminum, has a UV-resistant coating and complies
with the IP67 protection
class (IP65 for panel
mount).

Each type of burner must


fulfill different requirements depending on the
system. KRAL offers individual solutions consisting
of pumps for oil supply,
Volumeters for fuel flow
measurement and the
KRAL BEM 2U to display
the measured values.

The measuring accuracy


of the KRAL Volumeter
is highly regarded by
9 European national flow
laboratories. In a comparison of these labs, the
Volumeter reached an
accuracy of 0,015% on
test benches for fuel! The
high measuring accuracy
applies over a wide flow
and viscosity range. Processes which have very
low flows also require
high accuracy and resolution. Examples are filling
and mixing. The resolution
with KRAL Volumeters is
up to 0,1 ml per pulse.
Each pulse is detected,
evaluated and contributes
to the high accuracy of
the measurement.

We are a manufacturer of
high-precision flowmeters.
KRAL Volumeters have an
excellent international
reputation. We know the
requirements for flow
measurement from our
own experience.

On request, KRAL supply


stations for oil burners can
be enhanced with pressure regulators, vents, filters and gas / air separators.

Application examples for


the KRAL BEM 2U: For
water injection measurement and fuel consumption
measurement for turbines,
on burner stations and for
additive injection in the
chemical industry.

Our customers not only


have a flowmeter and
display, they also have a
competent partner in all
questions regarding flow
measurement.

Take advantage of our


experience as a flowmeter manufacturer.

Subject to change 01/04

enderwerbung.com

Krutler GmbH & Co., Bildgasse 40, A-6893 Lustenau, Austria, Telephone: +43 / (0) 55 77 / 8 66 44-0, Telefax: +43 / (0) 55 77 / 8 84 33
www.kral.at, E-mail: kral@kral.at

You might also like