IndustrialEthernet

500IND

10GIG

S/FTP,Category6A

Type
Cablestructure

IndustrialArea
S/FTP4x2xAWG22/1

Innerconductordiameter:
Coreinsulation:
Corecolours:
Strandingelement:
Separator:
Innersheathmaterial:
Shielding1:
Totalshielding:
Drainwire:
Outersheathmaterial:
Cableexternaldiameter:
Outersheathcolour:

Copper,bare (AWG22/1)
Foam-skin-PE
wh/bu,wh/og,wh/gn,wh/bn
Doublecore
FRNC
Al-Foil
AL-Foil+braid
yes
PVC
app.9,6mm0,3mm
GreensimilartoRAL6018

Electricaldata
Characteristicimpedance:

Conductorresistance,max.:
Insulationresistance,min.:
Loopresistance:
Mutualcapacitance:
Testvoltage:
Relativepropagationvelocity:

100Ohm 15Ohmat1to100MHz
100Ohm 20Ohmat101to500MHz
59Ohm/km
0,5GOhmxkm
118Ohm/kmmax.
72nF/kmnom.
0,7kV
62 %

Typicalvalues
Frequency
Attenuation
Next
PSNext

(MHz)
(db/100m)
(dB)
(dB)

10
5,9
60,3
57,3

16
7,5
57,2
54,2

62,5
15,0
48,4
45,4

100
19,1
45,3
42,3

250
31,1
39,3
36,3

500
45,3
34,8
31,8

Technicaldata
Weight:
bendingradius,repeated:
Operatingtemperaturerangemin.:
Operatingtemperaturerangemax.:
Caloricload,approx.value:
Copperweight:

app.115kg/km
80mm
-20C
+60C
1,63MJ/m
44,00kg/km

29.09.2015/Dimensionsandspecificationsmaybechangedwithoutpriornotice.

Norms
Acc.toISO/IEC11801,Acc.toEN50173,Acc.toEIA/TIA568-A,Category6A,CMGFT4

Application
HELUKAT 500INDwasdesignedspeciallyforextremeindustrialapplicationsforfixedinstallation.Thecopperdatacableisespeciallywell-suitedfor
Category6A10Gigabit/500MHz(IEC61156-5) Ethernetapplications.Itguaranteesexcellenttransmissioncharacteristicsandmaybeusedeven
undertheharshestconditions.

Partno.

803693, INDUSTRIALETHERNETKAT.6A10GIGPVC

Dimensionsandspecificationsmaybechangedwithoutpriornotice.