Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

24531 Page 94 Thursday, October 25, 2001 6:02 PM

Dimensions

TeSys contactors
Model d contactors
Control circuit: a.c.

LC1-D09D18 (3-pole)

LC1-D25D38 (3-pole)
LC1-DT20DT60 (4-pole)

44
Minimum electrical
clearance

44

Minimum electrical
clearance

LA4

b1

b1

LA4

D09
D18
77
94
110 (1)
119 (1)
126 (1)
84
86
117
129
137
141

D093
D183
99
107
123 (1)
132 (1)
139 (1)
84
86
117
129
137
141

D099
D189
80
95.5
111.5 (1)
120.5 (1)
127.5 (1)
84
86
117
129
137
141

LA4

Minimum electrical
clearance

D40008

a
b1 with LA4-Dp2
with LA4-DB3
with LA4-DF, DT
with LA4-DM, DR, DW, DL
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD-N (1 contact)
with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK
c3 with LAD-T, R, S
with LAD-T, R, S and sealing cover
LC1-D115 and D150 (3-pole)
LC1-D115004 (4-pole)

75
135

142
150
114
119
139
147
159
167
171

85
135

142
150
125

139
147
159
167
171

LC1-

D115
D150
120
174
185
188
188
132
136
150
155
168
172

2/94

DT203
& DT253
99

90
92
123
135
143
147

DT32
DT60
91

98
100
131
143
151
155

12,5
(LAD-8)

c1
c2
c3

D80
D65004
85
135
135
142
150
125
130
150
158
170
178
182

DT323
& DT603
105

98
100
131
143
151
155

44
LA4

D95
D65008
85
135

142
150
125
130
150
158
170
178
182

12,5
(LAD-8)

D80004

D80008

96
135

142
150
125

150
158
170
178
182

96
135

142
150
140

150
158
170
178
182

Minimum electrical
clearance

Characteristics:
pages 2/62 to 2/67

45

32

12

12,5
(LAD-8)

D40D65

a
b1 with LA4-DA2
with LA4-DF, DT
with LA4-DM, DR, DL
with LA4-DW
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK20
c3 with LAD-T, R, S
with LAD-T, R, S and sealing cover

DT20
& DT25
85
98
114
129
190
90
92
123
135
143
147

D253
& D323
99
107
123 (1)
132 (1)
139 (1)
90
92
123
135
143
147

LC1-D80 and D95 (3-pole)


LC1-D80004 and D80008 (4-pole)

LC1-

Selection:
pages 1/12 to 1/35

D25
D38
85
98
114 (1)
123 (1)
130 (1)
90
92
123
135
143
147

b1
12,5
(LAD-8)

c
c1
c2
c3

12,5
(LAD-8)

44

32

Minimum electrical
clearance

12

c
c1
c2
c3

127

2.3

b without add-on blocks


b1 with LAD-4BB
with LA4-Dp2
with LA4-DF, DT
with LA4-DR, DW, DL
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK10, LAD-6K10
c3 with LAD-T, R, S
with LAD-T, R, S and sealing cover
(1) Including LAD-4BB
LC1-D40D65 (3-pole)
LC1-D65004, D40008 and D65008 (4-pole)

10

b1

LC1-

45

LAD-8

LA4

D115004 D115006 D150006 D1150046

150
174
185
188
188
132

150
155
168
172

120
174
185
188
188
115

150
155
168
172

120
174
185
188

115

150
155
168
172

References:
pages 2/74 to 2/77

155
174
185
188
188
115

150
155
168
172

10
b1

12,5
(LAD-8)

c
c1
c2
c3

158

10

127

c1
c2
c3

Schemes:
pages 2/98 and 2/99
Schneider Electric

LC1-D25D38 (3-pole)

10

LC1-D09D18 (3-pole)

45

LC1b
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK10
c3 with LAD-T, R, S
with LAD-T, R, S and sealing cover

45

10

c1
c2
c3

c1
c2
c3
D09D18
77
93
95
126
138
146
150

D093D183
99
93
95
126
138
146
150

D099D189
80
93
95
126
138
146
150

D25D38
85
99
101
132
144
152
156

D253 & D323


99
99
101
132
144
152
156

LC1-DT20 to DT60 (4-pole)

2.3

LC1b
c
c1
c2
c3

with cover
with LAD-N or C (2 or 4 contacts)
with LA6-DK10
with LAD-T, R, S
with LAD-T, R, S and sealing cover

DT20 & DT25


D098 & D128
85
90
123
135
143
147

DT203 & DT253


D0983 & D1283
99
90
123
135
143
147

LC1-D40D65 (3-pole)
LP1-D65004, LP1-D40008D65008 (4-pole)

without cover or add-on blocks


with cover, without add-on blocks
c1 with LAD-N (1 contact)
with LAD-N or C (2 or 4 contacts)
c2 with LA6-DK10
c3 with LAD-T, R, S
with LAD-T, R, S and sealing cover
LC1-D115004: see page 2/94.

Schneider Electric

DT32DT60
D188D328
91
98
131
143
151
155

DT323 & DT403


D1883 & D2583
105
98
131
143
151
155

LC1-D80 and D95 (3-pole)


LP1-D80004, LP1-D80008 (4-pole)

LC1D40D65
171
176
196
202
213
221
225

LP1-D65004
171

196
202
213
221
225

LP1-D40008
& D65008
182

196
202
213
221
225

LC1D80 & D95


181
186
204
210
221
229
233

LP1D80004
181

204
210
221
229
233

LP1D80008
196

204
210
221
229
233

2/95

24531 Page 96 Thursday, October 25, 2001 6:02 PM

Mounting

TeSys contactors
Model d contactors

On mounting rail AM1-DL200 or DL201 (width 75 mm)


On mounting rail AM1-EDppp or AM1-DE200 (width 35 mm)
LC1-D40 to D95, LP1-D40 to D80

127

On mounting rail AM1-DP200, DR200 or AM1-DE200 (width 35 mm)


LC1-D09D38, DT20DT60

c
c

LC1-

D09D18 D25D38 DT20


& DT25
77
85
85
88
94
94
96
102
102

b
c (AM1-DP200 or DR200) (1)
c (AM1-DE200) (1)

DT32
DT60
100
109
117

d.c. control circuit


b
c (AM1-DP200 or DR200) (1)
c (AM1-DE200) (1)

77
97
105

85
103
110

94
103
111

109
118
1236

D40D65
136
126
126

D80 & D95


147
137
137

d.c. control circuit


LC1c (AM1-DL200) (1)
c (AM1-DL201) (1)

D40D65
193
183

D80 & D95


203
203

LP1c (AM1-DL200)
c (AM1-DL201)

D40
188
178

D80
198
198

D65
188
178

(1) with safety cover

158

100

(1) with safety cover


On 2 mounting rails DZ5-MB at 120 mm centres
LC1-D115, D150

a.c. or d.c. control circuit


LC1c (AM1-DP200 or DR200)
c (AM1-DE200 or EDppp)

=
c

D115 & D150


134.5
142.5

D1156 & D1506


117.5
125.5

On 2 mounting rails DZ5-MB at 120 mm centres


LC1-D40D95, LP1-D40D80

15

110

DZ5-ME5

120

2.3

a.c. control circuit


LC1c (AM1-DL200) (1)
c (AM1-DL201) (1)
c (AM1-EDppp or DE200) (1)

40

a.c. control circuit


LC1c with cover

D40D65
119

D80 & D95


130

d.c. control circuit


LC1c with cover
LP1c

D40D65
176
D40 & D65
171

D80 & D95


186
D80
181

Selection:
pages 1/12 to 1/35
2/96

Characteristics:
pages 2/62 to 2/67

References:
pages 2/74 to 2/77

Schemes:
pages 2/98 and 2/99
Schneider Electric

24531 Page 97 Thursday, October 25, 2001 6:03 PM

Mounting

TeSys contactors
Model d contactors

LC1-D09 to D38 and LC1-DT20DT60


On 2 mounting rails DZ5-MB

Control circuit:
LC1c with cover
G
H
H1
4-pole contactors
LC1-

H1

DZ5-ME8

15

G
c
G
H
H1

D25D38
92
35
60
70

d.c.
D09D18
95
35
60
70

D25D38
101
35
60
70

DT20
& DT25
92
135
60
70

DT32
DT60
100
40/50
60
70

DT20
& DT25
101
35
60
70

DT32
DT60
109
35
60
70

LC1-D40D95, LP1-D40D80
On pre-slotted mounting plate AM1-PA, PB, PC

110

LC1-D09D38 and LC1-DT20DT60


On pre-slotted mounting plate AM1-PA, PB, PC

a.c.
D09D18
86
35
60
70

2.3

AF1-EA4

Control circuit:
LC1c with cover
G
c with cover
4-pole contactors
LC1c
G
H

a.c.
D09D18
86
35
86
DT20
& DT25
80
35
60

D25D38
92
35
92

d.c.
D09D18
95
35
95

D25D38
101
35
101

DT32
DT60
93
35
60

DT20
& DT25
118
35
60

DT32
DT60
132
35
60

Control circuit:
LC1c with cover
LP1c without cover

a.c.
D40D65
119

D80 & D95


130

AF1-EA6

d.c.
D40D65
176
D40 & D65
171

LC1-D40D95, LP1-D40 to D80


Panel mounted

35

100/110

=
=

60/70

2xM4

c
Control circuit:
LC1c with cover
4-pole contactors
LC1c with cover

D80 & D95


186
D80
181

LC1-D09D38
Panel mounted

40

a.c.
D09D18
86
DT20
& DT25
90

d.c.
D09D18
95

D25D38
92
DT32
DT60
98

DT20
& DT25
90

D25D38
101
DT32
DT60
98

Control circuit:
LC1c with cover
LP1c without cover

a.c.
D40D65
119

40

D80 & D95


130

3x6,5

d.c.
D4D65
176
D40 & D65
171

D80 & D95


186
D80
181

130
158

LC1-D115, D150
Panel mounted

Selection:
pages 1/12 to 1/35
Schneider Electric

Characteristics:
pages 2/62 to 2/67

LC1c
G (3-pole)
G (4-pole)

References:
pages 2/74 to 2/77

D115
132
96/110
130/144

D1156
115
96/110
130/144

D150
132
96/110

D1506
115
96/110

Schemes:
pages 2/98 and 2/99
2/97

2/98
13/NO
21/NC
31/NC

14
22
32
43/NO

21/NC

22

61/NC

62

63/NO

R1

1
3
R3

R2

2
4
R4

A1

R4

A2

R1
R3

R2

A1

A2

21/NC

7/L4

T4/8

3/L2
5/L3

22

5/L3

T3/6

1/L1

13/NO

T3/6

3/L2

A1

14

T2/4

1/L1
T1/2

A2

T2/4

A1

T1/2

A2

(91)(9 633.163 .942 8392 705 lSEMC1 1 1 rg/GS2 gs2NO

64

53/NO

53/NO

54

54

41/NC
(92)

(94)

43 NO
43/NO

42
(91)

44
(93)

2.3

44

13/NO

14

54

Schneider Electric

A1

Schneider Electric

A1
A1

A2

K
K

A1

A2
A2

A1

A2

E2

E1 +

A1

A2

A2

E2

E1 +

E2
E2

E1
E1+
+

E2

E1 +

A2

B1

(1)

A1

(184)
161/NC
(172)

153/NO
(184)
163/NO
(174)

151/NC
(182)
161/NC
(172)

162
(171)

154
(183)
164
(173)

152
(181)
162
(171)

153/NO

154
(183)

E2

A2
A1

E1

61/NC
73/NO
83/NO

62

84

53/NO

54

74

83/NO

84

68

73/NO

63/NO

64

67/NO

56

74

53/NO

54

55/NC

66

53/NO

61/NC

62

65/NC

58

63/NO

51/NC

52

57/NO

68

64

63/NO

64

67/NO

54

53/NO

54

55/NC

56

2.3

2/99

24533 Page 100 Friday, October 26, 2001 9:06 AM

Dimensions

TeSys contactors
Model d reversing contactors

LC2-D09 to D38
2 x LC1-D09 to D38

LC2-DT20 to DT60
2 x LC1-DT20 to DT60

LC2- or 2 x LC1a
b
c (1)
D09 to D18 a
90
77
86
D093 to D183 a
90
99
86
D09 to D18 c
90
77
95
D093 to D183 c
90
99
95
D12004

74
80
D25 to D38 a
90
85
92
D253 to D383 a
90
99
92
D25 to D32 c
90
85
101
D253 to D383 c
90
99
101
D25004

84
93
e1 and e2: including cabling.
(1) With safety cover, without add-on block.
LC2-D40 to D65
2 x LC1-D40 to D65
6x6,5

e1
4

e2
1.5

1.5

6
5

G
80
80
80
80
95
80
80
80
80
111

LC2- or 2 x LC1- a
DT20 and DT25 90
DT32DT60
90
c, e: including cabling.

b
85
91

c
90
98

G
80
80

2 x LP1-D40 and D65


=

6x6,5
G1

40

100/110
13

40 =

a
LC2- or 2 x LC1D40 to D65
165
D40004
182
D65004
182
D80 and D95
182
D80004
207
c, e1 and e2: including cabling.

b
127
127
127
127
127

c
142
133
133
158
158

e1
5

13

e2

11
11

20

G
50
57
57
57
71

G1
90
97
97
96
111

e2

13

100/110

G1

e1

e1

b
c

e2

e2

e2

LC2- or 2 x LC1- a
b
D40 to D65
182
127
D80 and D95
207
127
c, e1 and e2: including cabling.

40

40

c
190
215

e1
5
13

e2
11
20

G
57
96

G1
97
111

130

158

e1

LC2-D115 and D150


2 x LC1-D115 and D150

LC2- or 2 x LC1D115, D150


D115004
c, e1 and e2: including cabling.

Selection:
pages 1/12 to 1/35
2/100

e2

2.3

60/70

2xM4

60/70

e1

2xM4

a
266
334

c
148
148

Characteristics:
pages 2/62 to 3/67

e1
56

e2
18
60

G
242/256
310/324

References:
pages 2/74 to 2/83

Schemes:
page 2/101
Schneider Electric

24533 Page 101 Friday, October 26, 2001 9:07 AM

Schemes

TeSys contactors
Model d reversing contactors

A1

A2

21/NC
22

13/NO

5
6

14

3
4
V

1
2
U

21/NC
22

L3
5

13/NO

L2
3

14

L1
1

A1
A2

A1

Reversing contactors for motor control with integral electrical


interlocking (LAD-9R1V)

A2

21/NC
22

14

13/NO

21/NC
22

L3
5

13/NO

L2
3

14

L1
1

A2

A1

Reversing contactors for motor control, horizontally mounted


LC2-D09D150

A1

2.3

A2

mechanical interlock without integral electrical contacts


LA9-Dppp78, LAD-9R1

KM2

KM1

A1

01
A1

02

01
A1

02

A2

A1

01

A2

A1

Electrical interlocking of reversing contactors fitted with:


mechanical interlock with integral electrical contacts
LA9-Dppp02

A1

2N
7
8
N

2/L3
5
6

2/L2

L3

2/L1

3
4

1
2

L2

1N
7

L1

1/L3
5

1/L2
3

1/L1
1

A2

A1

Changeover contactor pairs, horizontally mounted


LC2-DT20DT60

01
KM1

KM2

KM2
A2

KM1
A2

A2

KM2
A2

KM1

A2

A2

02

02

A1
A2

22

21/NC

13/NO

5
6

14

3
4
V

1
2
U

21/NC
22

L3
5

13/NO

14

L2
3

Selection:
pages 1/12 to 1/35
Schneider Electric

R3
R4

R1
R2

Low speed

1
2

A1

LAD- LS/HS

A2

L1
1

A1
A2

Low speed - High speed cabling kit

High speed

Characteristics:
pages 2/62 to 3/67

References:
pages 2/74 to 2/83

Dimensions:
page 2/100
2/101

You might also like