Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

A

Trunnion Weld Size Deisgn

1
2
3

Weld size between the Trunnion and the beam

4
5
6
7
8
9

Yield stress of the weld

fyweld

Design strength of the fillet weld

=
=

60 ksi
414 N/mm2

=
=

10

0.3fyweld
0.3x414

124 N/mm2

11
12

Weld size provided

12 mm

=
=
=
=
=

170 mm
194 mm
xD
3.14x170
401 mm

401 mm

13
14
15
16
17
18
19
20
21
22
23
24

Diameter of Trunnion
Diameter of Weld
Perimeter of Truniion

Length of the weld provided

Lweld

Strength of the weld

=
=
=

0.7*s*Lweld*Design Strength of
0.7x12x401x125
417.52 kN

25
26

Tensile force in the sling

27
28
29
Factor of safety
30
31 Section Modulus of Weld
32
33

417.52
417.52/391.44

=
>
SAFE
=

391.43 kN
391.43
1.067

*((d2)4-(d1)4)
32d1

35 Bending Moment

=
=

335676.00 mm3
121343920 Nmm

36 Bending stress of Weld

361.491204 N/mm2

37

<

414 N/mm2

34

38

Hence Safe

ion Weld Size Deisgn

1
2
3

Input Cells

4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
0.7*s*Lweld*Design Strength
of the Weld
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

Support Plate Weld Size Deisgn

1
2
3

Weld size between the Trunnion and the beam

4
5
6
7
8
9

Yield stress of the weld

fyweld

Design strength of the fillet weld

=
=
=
=

10

60 ksi
414 N/mm2
0.3fyweld
0.3x414
124 N/mm2

11
12

Weld size provided

12 mm

=
=
=
=

170 mm
xD
3.14x170
534 mm

534 mm

13
14
15
16
17
18
19
20
21
22
23

Diameter of Trunnion
Perimeter of Truniion

Length of the weld provided

Lweld

Strength of the weld

=
=
=

0.7*s*Lweld*Design Strength o
0.7x12x535x125
556.76 kN

24
25
26
27
28
29

Tensile force in the sling


556.76
Factor of safety

556.77/527

=
>
SAFE
=

527.00 kN
527.00
1.056

1
Plate Weld Size Deisgn
2
3

Input Cells

4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21Strength of the Weld
0.7*s*Lweld*Design
22
23
24
25
26
27
28
29

Load Calculation
Self Weight
Self Weight of HE 200 B
=
=
Length of the Member
=
Load
=
Length of the Member
=
Load
=
Self Weight of upn 120
=
=
Length of the Member
=
Load
=
Total Load
=
Equipment
Total Weight of the Equipment
Area
Load
Influence Area
Load

Load
=
=
=
=
=

Grating Load
Load considered
=
Influence Area
=
Load
=
Total Load
Load per Support

=
=

Self Weight of HE 200B


Self Weight of HE 200 B
=
=
Length
=
Load
=
Total Load Governing Weld
Factored Load

=
=

eight
61.3 kg/m
0.60 kN/m
25.38 m
15.26 kN
1.20 m
0.72 kN
13.4 kg/m
0.13 kN/m
29.46 m
3.87 kN
19.85 kN

nt Load
220.00 kN
25.38 m2
8.666638 kN/m2
12.69235 m2
110 KN
Load
0.25 kN/m2
12.7 m2
3.17 KN
133.02 kN
66.51 kN

f HE 200B
61.3 kg/m
0.60 kN/m
6.1 m
3.67 kN
70.18 kN
105.27 kN

Weld Size Deisgn

1
2
3

Weld size Determination

4
5
6
7
8
9

Yield stress of the weld

fyweld

Design strength of the fillet weld

=
=
=
=

10

60 ksi
414 N/mm2
0.3fyweld
0.3x414
124 N/mm2

11
12
13
14
15
16
17
18

Weld size provided

10 mm

Length of the weld provided

Lweld

170 mm

Strength of the weld

=
=
=

0.7*s*Lweld*Design Strength o
0.7x10x170x125
147.69 kN

19
20
21
22
23
24

Tensile force in the sling


147.69
Factor of safety

147.69/127

=
>
SAFE
=

127.00 kN
127.00
1.163

Weld Size Deisgn

1
2
3

Input Cells

4
5
6
7
8
9
10
11
12
13
14
15
16Strength of the Weld
0.7*s*Lweld*Design
17
18
19
20
21
22
23
24

You might also like