Professional Documents
Culture Documents
Trunnion Weld Size Design
Trunnion Weld Size Design
1
2
3
4
5
6
7
8
9
fyweld
=
=
60 ksi
414 N/mm2
=
=
10
0.3fyweld
0.3x414
124 N/mm2
11
12
12 mm
=
=
=
=
=
170 mm
194 mm
xD
3.14x170
401 mm
401 mm
13
14
15
16
17
18
19
20
21
22
23
24
Diameter of Trunnion
Diameter of Weld
Perimeter of Truniion
Lweld
=
=
=
0.7*s*Lweld*Design Strength of
0.7x12x401x125
417.52 kN
25
26
27
28
29
Factor of safety
30
31 Section Modulus of Weld
32
33
417.52
417.52/391.44
=
>
SAFE
=
391.43 kN
391.43
1.067
*((d2)4-(d1)4)
32d1
35 Bending Moment
=
=
335676.00 mm3
121343920 Nmm
361.491204 N/mm2
37
<
414 N/mm2
34
38
Hence Safe
1
2
3
Input Cells
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
0.7*s*Lweld*Design Strength
of the Weld
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
1
2
3
4
5
6
7
8
9
fyweld
=
=
=
=
10
60 ksi
414 N/mm2
0.3fyweld
0.3x414
124 N/mm2
11
12
12 mm
=
=
=
=
170 mm
xD
3.14x170
534 mm
534 mm
13
14
15
16
17
18
19
20
21
22
23
Diameter of Trunnion
Perimeter of Truniion
Lweld
=
=
=
0.7*s*Lweld*Design Strength o
0.7x12x535x125
556.76 kN
24
25
26
27
28
29
556.77/527
=
>
SAFE
=
527.00 kN
527.00
1.056
1
Plate Weld Size Deisgn
2
3
Input Cells
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21Strength of the Weld
0.7*s*Lweld*Design
22
23
24
25
26
27
28
29
Load Calculation
Self Weight
Self Weight of HE 200 B
=
=
Length of the Member
=
Load
=
Length of the Member
=
Load
=
Self Weight of upn 120
=
=
Length of the Member
=
Load
=
Total Load
=
Equipment
Total Weight of the Equipment
Area
Load
Influence Area
Load
Load
=
=
=
=
=
Grating Load
Load considered
=
Influence Area
=
Load
=
Total Load
Load per Support
=
=
=
=
eight
61.3 kg/m
0.60 kN/m
25.38 m
15.26 kN
1.20 m
0.72 kN
13.4 kg/m
0.13 kN/m
29.46 m
3.87 kN
19.85 kN
nt Load
220.00 kN
25.38 m2
8.666638 kN/m2
12.69235 m2
110 KN
Load
0.25 kN/m2
12.7 m2
3.17 KN
133.02 kN
66.51 kN
f HE 200B
61.3 kg/m
0.60 kN/m
6.1 m
3.67 kN
70.18 kN
105.27 kN
1
2
3
4
5
6
7
8
9
fyweld
=
=
=
=
10
60 ksi
414 N/mm2
0.3fyweld
0.3x414
124 N/mm2
11
12
13
14
15
16
17
18
10 mm
Lweld
170 mm
=
=
=
0.7*s*Lweld*Design Strength o
0.7x10x170x125
147.69 kN
19
20
21
22
23
24
147.69/127
=
>
SAFE
=
127.00 kN
127.00
1.163
1
2
3
Input Cells
4
5
6
7
8
9
10
11
12
13
14
15
16Strength of the Weld
0.7*s*Lweld*Design
17
18
19
20
21
22
23
24