Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

SPECIFICATION OF NALCO EQUIPMENT

NO

EQUIPMENT NAME
1 Polymer Makedown for Anionic polymer

SPESIFICATION/UNIT
Polymer pump : Progressive cavity pump
Mixing pump : Multistage centrifugal pump
Polymer pump control : inverter
Start/stop control : Manual and Level control
Motor Polymer pump : 3 phase, 0.37 kW
Motor Mixing pump : 3 phase, 5.5 kW

QTY

DIMENSION
1000X2200X1600

2
2

TAG NUMBER

452130 / 452131
452132 / 452133

2 Water booster pump for Anionic makedown

Multistage centrifugal pump


Cap : 16 m3, Head : 50 m
Motor : 3 phase, 500 VAC, 5.5 kW

600x600x800

3 Base tank + Agitator for anionic base tank

Capacity : 1000 kg
Motor : 3 phase, 500 VAC, 0.75 kW

1500x1500x1600

4 Fresh water tank + floating valve

Materials : PE
Capacity : 2.2 m3

1500x1500x2200

5 Booster pump for Pareto

Multistage centrifugal pump


Flow control : inverter (DCS)
Capacity : 32 m3 @ 120 m
Flow measure : Magnetic flow meter
Utility : 3 phase, 500 VAC, 15 kW

6 Anionic feeder

Progressive cavity pump


Cap : 2500 lph @ 10 bar
Flow control : Inverter (DCS)
Flow measure : Magnetic flow meter
Utility : 3 phase, 500 VAC, 8 kW

1600x1000x1500

7 Silica feeder

Progressive cavity pump


Cap : 150 lph @ 12 bar

1200x1000x1500

452105 / 452106

452134

452126
452127
452128

Flow control : Inverter (DCS)


Flow measure : Magnetic flow transmitter
Utility : 3 phase, 380 VAC, 2 kW
8 Cationic feeder

Progressive cavity pump


Cap : 4000 lph @ 10 bar
Flow control : Inverter (DCS)
Flow measure : Magnetic flowmeter
Utility : 3 phase, 380 VAC, 8 kW

9 Cationic makedown system

1600x1000x1500

belong to IKPP

10 Anionic solution tank

Material : Stainless Steel


Capacity : 10 m3

belong to IKPP

4521160

11 Cationic solution tank

Materials : Stainless steel


Capacity : 10 m3

belong to IKPP

4521620

12 Silica storage tank

Materials : FRP
Capacity : 30 m3

dia 3500x3500

4421644

13 Duplex Filter

Materials : SS
Screen mesh : 60 mesh

NOTE :
1. For all voltage of instrument and control We use stepdown transformer, included on our Control Panel package
2. The number of power cable core is 4 core = 3 phase + 1 ground
3. Number of unit of equipment = 2 (two) units, 1 (one) unit live + 1 (one) unit back-up

You might also like